HomeMy WebLinkAboutDRB150486_A8-1_1446737340.pdfWINDOW RE: WINDOW SCHEDULE
STUFFED IN INSULATION AND SHIM AS REQ'D
SEE 1/A6.1 FOR TYP. STONE VENEER WALL ASSEMBLY
LAP WATERPROOF
MEMBRANE OVER NAILING
FLANGE AND CONTINUE UP
UNDER FLASHING AND
UNDER BUILDING PAPER
STL. C-CHANNEL STEEL HEADER
PAINTED DARK BLUE/BLACK LAG
BOLTED THROUGH CENTER OF
C-CHANNEL TO WINDOW HEADER
RE: STRUCT.
GRID
LINE
INTERIOR
EXTERIOR
COPPER FLASHING
HEADER RE: STRUCT.
ALUMINUM FLASHING TO MATCH
WINDOW SEPARATE FROM STEEL
HEADER WITH ICE AND WATER SHIELD
AND SEALANT
3D DRAINAGE MEDIUM
LAPS OVER BUILDING
PAPER LAPS OVER TOP
OF FLASHING 1 1/2" MIN
AND CONT. UP WALL
CUSTOM JAMB PER EXTENDED DEPTH
TRIM PER INTERIOR DOCUMENTS
PROVIDE WEEP AT TOP OF WINDOW
PROVIDE 1X BACKER
BOARD BEHIND STEEL
HEADER
2 3/8"
WINDOW RE: WINDOW SCHEDULE
STUFFED IN INSULATION AND SHIM AS REQ'D
SEE 1/A6.1 TYP. EXT. STONE SIDING WALL ASSEMBLY
LAP BUILDING PAPER OVER 1ST
LAYER OF WATERPROOF
MEMBRANE
LAP 2ND LAYER OF
WATERPROOF MEMBRANE
OVER 1ST LAYER AND
OVER 3D DRAINAGE
MEDIUM AND OVER
BUILDING PAPER
GRID
LINE
INTERIOR
EXTERIOR
LAP 1ST LAYER OF
WATERPROOF MEMBRANE
OVER SHEATHING AND
OVER NAILING FLANGE
1/4" SEALANT JOINT AND
BACKER ROD DO NOT LET
MORTAR TOUCH WINDOW
USE SANDED CAULK JOINT
AT STONE TO ADJACENT
WINDOW
CUSTOM WOOD JAMB PER EXTENDED WIDTH
TRIM PER INTERIOR DOCUMENTS
2 3/8"
WINDOW RE: WINDOW SCHEDULE
WINDOW SET IN BED OF SEALANT
SEE 1/A6.1 FOR TYP. EXT.
STONE SIDING WALL ASSEMBLY
2" STONE RUBBLE TOP SILL
SLOPED TO DRAIN
GRID
LINE
INTERIOR
EXTERIOR
LAP WATERPROOF
MEMBRANE OVER 3D
DRAINAGE MEDIUM OVER
BLDG. PAPER AND UNDER
WINDOW SILL
CUSTOM SILL PER INTERIOR DOCUMENTS
TRIM PER INTERIOR DOCUMENTS
WINDOW RE: WINDOW SCHEDULE
STUFFED IN INSULATION AND SHIM AS REQ'D
SEE _ / A_._ FOR TYP. WOOD
SIDING WALL ASSEMBLY
3D DRAINAGE MEDIUM
LAPS OVER BUILDING
PAPER LAPS OVER TOP
OF FLASHING 1 1/2" MIN
LAP WATERPROOF
MEMBRANE OVER NAILING
FLANGE AND CONTINUE
UP UNDER FLASHING AND
UNDER BUILDING PAPER
3X3 WOOD TRIM
GRID
LINE
CUSTOM JAMB PER EXTENDED DEPTH
INTERIOR
EXTERIOR
COPPER FLASHING
HEADER RE: STRUCT.
TRIM PER INTERIOR DOCUMENTS
CONTINUOUS 1X4
HORIZONTAL FURRING
STRIPS @ 2'-0" O.C. OVER
3D DRAINAGE MEDIUM AND
AIR INFILTRATION BARRIER
2 3/8"
WINDOW RE: WINDOW SCHEDULE
STUFFED IN INSULATION AND SHIM AS REQ'D
SEE _ / A_._ FOR TYP. WOOD SIDING
WALL ASSEMBLY
LAP BUILDING PAPER OVER 1ST
LAYER OF WATERPROOF
MEMBRANE
LAP 2ND LAYER OF
WATERPROOF MEMBRANE
OVER 1ST LAYER AND
OVER 3D DRAINAGE
MEDIUM AND OVER
BUILDING PAPER
GRID
LINE
INTERIOR
EXTERIOR
CUSTOM WOOD JAMB PER EXTENDED WIDTH
LAP 1ST LAYER OF
WATERPROOF MEMBRANE
OVER SHEATHING AND
OVER NAILING FLANGE
SEALANT JOINT AND BACKER ROD
3X3 WOOD TRIM
TRIM PER INTERIOR DOCUMENTS
5 1/2"
2 3/8"
WINDOW RE: WINDOW SCHEDULE
WINDOW SET IN BED OF SEALANT
SEE _ / A_._ FOR TYP. WOOD
SIDING WALL ASSEMBLY
LAP WATERPROOF
MEMBRANE OVER 3D
DRAINAGE MEDIUM OVER
BLDG. PAPER AND UNDER
WINDOW SILL
GRID
LINE
CUSTOM SILL PER INTERIOR DOCUMENTS
INTERIOR EXTERIOR
3X3 WOOD TRIM WITH
SLOPED TOP TO DRAIN
TRIM PER INTERIOR DOCUMENTS
CONTINUOUS 1X4
HORIZONTAL FURRING
STRIPS @ 2'-0" O.C. OVER
3D DRAINAGE MEDIUM AND
AIR INFILTRATION BARRIER
EXTERIOR INTERIOR
BLOCKING
WOOD TRIM
LINE OF WINDOW JAMB BEYOND
ICE & WATER SHIELD
CONTINUOUS UNDER SILL
SEALANT
IN-FILL W/ EXPANDING
SPRAY FOAM INSULATION
AND SHIM AS REQ.
STL. C-CHANNEL RE: STRUCT
GRID
LINE
EXTERIOR
INTERIOR
(1) 1 3/4" X 5.5" LVL MICROLAMS
9/16" WOOD TRIM RE: SPEC
SEALANT
3/8" GRID
LINE
1/2" PLYWOOD FILLER
ATTACHED TO DOOR
FRAME SIDE OF HEAD
ONLY
3/8"
CUSTOM 4/4 WOOD JAMB
EXTENSION
3/16" 3 7/8" 3/16"
5/8" X 5/8" WOOD TRIM
IN-FILL W/ EXPANDING
SPRAY FOAM INSULATION
& SHIM
ALUMINUM CLAD PANEL
WINDOW RE: WINDOW SCHEDULE
STUFFED IN INSULATION AND SHIM AS REQ'D
SEE _ / A_._ FOR TYP.
COPPER SHINGLE SIDING
WALL ASSEMBLY
3D DRAINAGE MEDIUM
LAPS OVER BUILDING
PAPER LAPS OVER TOP
OF FLASHING 1 1/2" MIN
LAP WATERPROOF
MEMBRANE OVER NAILING
FLANGE AND CONTINUE
UP UNDER FLASHING AND
UNDER BUILDING PAPER
3X3 WOOD TRIM
GRID
LINE
CUSTOM JAMB PER EXTENDED DEPTH
INTERIOR
EXTERIOR
COPPER FLASHING
HEADER RE: STRUCT.
TRIM PER INTERIOR DOCUMENTS
WINDOW RE: WINDOW SCHEDULE
STUFFED IN INSULATION AND SHIM AS REQ'D
SEE _ / A_._ FOR TYP. COPPER
SHINGLE SIDING WALL ASSEMBLY
LAP BUILDING PAPER OVER 1ST
LAYER OF WATERPROOF
MEMBRANE
LAP 2ND LAYER OF
WATERPROOF MEMBRANE
OVER 1ST LAYER AND
OVER 3D DRAINAGE
MEDIUM AND OVER
BUILDING PAPER
GRID
LINE
INTERIOR EXTERIOR
CUSTOM WOOD JAMB PER EXTENDED WIDTH
LAP 1ST LAYER OF
WATERPROOF MEMBRANE
OVER SHEATHING AND
OVER NAILING FLANGE
SEALANT JOINT AND BACKER ROD
3X3 WOOD TRIM
TRIM PER INTERIOR DOCUMENTS
2 3/8"
WINDOW RE: WINDOW SCHEDULE
WINDOW SET IN BED OF SEALANT
SEE _ / A_._ FOR TYP.
COPPER SHINGLE SIDING
WALL ASSEMBLY
LAP WATERPROOF
MEMBRANE OVER 3D
DRAINAGE MEDIUM OVER
BLDG. PAPER AND UNDER
WINDOW SILL
GRID
LINE
CUSTOM SILL PER INTERIOR DOCUMENTS
INTERIOR
EXTERIOR
3X3 WOOD TRIM WITH
SLOPED TOP TO DRAIN
TRIM PER INTERIOR DOCUMENTS
2 3/8"
EXTERIOR
INTERIOR
(1) 1 3/4" X 5.5" LVL MICROLAMS
WOOD TRIM
WINDOW JAMB BEYOND
ICE & WATER SHIELD
CONTINUOUS
UNDER SILL @ UPPER
WINDOW LAPS
OVER DOOR FRAME
SEALANT
3/8"
GRID
IN-FILL W/ EXPANDING
SPRAY FOAM INSULATION
AND SHIM AS REQ. 3/8" 2 1/2"
PFSM CLAD PANEL
RE:ELEVATIONS
EXTERIOR
INTERIOR
(1) 1 3/4" X 5.5" LVL MICROLAMS
WOOD TRIM
SEALANT
GRID
SPRAY FOAM VOID & SHIM AS
REQ.
WOOD JAMB EXTENSION
W/ WOOD TRIM
PFSM CLAD PANEL
RE: ELEVATIONS
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
3" = 1'-0"
10/12/2015
11:46:37 AM
A8.1
WINDOW
AND DOOR
DETAILS
AG
HB
REIMERS
RESIDENCE
10/12/2015
3090
BOOTH
CREEK DR. VAIL, CO
TOV FINAL DRB
SUBMITTAL
No. Revision Date
Revision
Description
3" = 1'-0"
1
WINDOW HEAD DETAIL @ STONE
VENEER
3" = 1'-0"
2
WINDOW JAMB DETAIL @ STONE
VENEER
3" = 1'-0"
3
WINDOW SILL DETAIL @ STONE VENEER
3" = 1'-0" 4
WINDOW HEAD DETAIL @ WOOD SIDING
3" = 1'-0"
5
WINDOW JAMB DETAIL @ WOOD SIDING
3" = 1'-0" 6
WINDOW SILL DETAIL @ WOOD SIDING
3" = 1'-0" 10
WINDOW HEADER TO WINDOW SILL
CONNECTION AT FRONT ENTRY
3" = 1'-0" 11
WINDOW JAMB TO WINDOW JAMB
CONNECTION AT FRONT ENTRY
3" = 1'-0"
7
WINDOW HEAD DETAIL @ COPPER
SHINGLES
3" = 1'-0"
8
WINDOW JAMB DETAIL @ COPPER
SHINGLES
3" = 1'-0"
9
WINDOW SILL DETAIL @ COPPER
SHINGLES
3" = 1'-0" 12
DOOR HEADER TO WINDOW SILL @
FRONT ENTRY
3" = 1'-0" 13
DOOR JAMB TO WINDOW JAMB @
FRONT ENTRY
DRB
APPROVED
11/4/2015
12:00:00 AM