HomeMy WebLinkAboutDRB150486_A8-1_1446737340.pdfWINDOW RE: WINDOW SCHEDULE STUFFED IN INSULATION AND SHIM AS REQ'D SEE 1/A6.1 FOR TYP. STONE VENEER WALL ASSEMBLY LAP WATERPROOF MEMBRANE OVER NAILING FLANGE AND CONTINUE UP UNDER FLASHING AND UNDER BUILDING PAPER STL. C-CHANNEL STEEL HEADER PAINTED DARK BLUE/BLACK LAG BOLTED THROUGH CENTER OF C-CHANNEL TO WINDOW HEADER RE: STRUCT. GRID LINE INTERIOR EXTERIOR COPPER FLASHING HEADER RE: STRUCT. ALUMINUM FLASHING TO MATCH WINDOW SEPARATE FROM STEEL HEADER WITH ICE AND WATER SHIELD AND SEALANT 3D DRAINAGE MEDIUM LAPS OVER BUILDING PAPER LAPS OVER TOP OF FLASHING 1 1/2" MIN AND CONT. UP WALL CUSTOM JAMB PER EXTENDED DEPTH TRIM PER INTERIOR DOCUMENTS PROVIDE WEEP AT TOP OF WINDOW PROVIDE 1X BACKER BOARD BEHIND STEEL HEADER 2 3/8" WINDOW RE: WINDOW SCHEDULE STUFFED IN INSULATION AND SHIM AS REQ'D SEE 1/A6.1 TYP. EXT. STONE SIDING WALL ASSEMBLY LAP BUILDING PAPER OVER 1ST LAYER OF WATERPROOF MEMBRANE LAP 2ND LAYER OF WATERPROOF MEMBRANE OVER 1ST LAYER AND OVER 3D DRAINAGE MEDIUM AND OVER BUILDING PAPER GRID LINE INTERIOR EXTERIOR LAP 1ST LAYER OF WATERPROOF MEMBRANE OVER SHEATHING AND OVER NAILING FLANGE 1/4" SEALANT JOINT AND BACKER ROD DO NOT LET MORTAR TOUCH WINDOW USE SANDED CAULK JOINT AT STONE TO ADJACENT WINDOW CUSTOM WOOD JAMB PER EXTENDED WIDTH TRIM PER INTERIOR DOCUMENTS 2 3/8" WINDOW RE: WINDOW SCHEDULE WINDOW SET IN BED OF SEALANT SEE 1/A6.1 FOR TYP. EXT. STONE SIDING WALL ASSEMBLY 2" STONE RUBBLE TOP SILL SLOPED TO DRAIN GRID LINE INTERIOR EXTERIOR LAP WATERPROOF MEMBRANE OVER 3D DRAINAGE MEDIUM OVER BLDG. PAPER AND UNDER WINDOW SILL CUSTOM SILL PER INTERIOR DOCUMENTS TRIM PER INTERIOR DOCUMENTS WINDOW RE: WINDOW SCHEDULE STUFFED IN INSULATION AND SHIM AS REQ'D SEE _ / A_._ FOR TYP. WOOD SIDING WALL ASSEMBLY 3D DRAINAGE MEDIUM LAPS OVER BUILDING PAPER LAPS OVER TOP OF FLASHING 1 1/2" MIN LAP WATERPROOF MEMBRANE OVER NAILING FLANGE AND CONTINUE UP UNDER FLASHING AND UNDER BUILDING PAPER 3X3 WOOD TRIM GRID LINE CUSTOM JAMB PER EXTENDED DEPTH INTERIOR EXTERIOR COPPER FLASHING HEADER RE: STRUCT. TRIM PER INTERIOR DOCUMENTS CONTINUOUS 1X4 HORIZONTAL FURRING STRIPS @ 2'-0" O.C. OVER 3D DRAINAGE MEDIUM AND AIR INFILTRATION BARRIER 2 3/8" WINDOW RE: WINDOW SCHEDULE STUFFED IN INSULATION AND SHIM AS REQ'D SEE _ / A_._ FOR TYP. WOOD SIDING WALL ASSEMBLY LAP BUILDING PAPER OVER 1ST LAYER OF WATERPROOF MEMBRANE LAP 2ND LAYER OF WATERPROOF MEMBRANE OVER 1ST LAYER AND OVER 3D DRAINAGE MEDIUM AND OVER BUILDING PAPER GRID LINE INTERIOR EXTERIOR CUSTOM WOOD JAMB PER EXTENDED WIDTH LAP 1ST LAYER OF WATERPROOF MEMBRANE OVER SHEATHING AND OVER NAILING FLANGE SEALANT JOINT AND BACKER ROD 3X3 WOOD TRIM TRIM PER INTERIOR DOCUMENTS 5 1/2" 2 3/8" WINDOW RE: WINDOW SCHEDULE WINDOW SET IN BED OF SEALANT SEE _ / A_._ FOR TYP. WOOD SIDING WALL ASSEMBLY LAP WATERPROOF MEMBRANE OVER 3D DRAINAGE MEDIUM OVER BLDG. PAPER AND UNDER WINDOW SILL GRID LINE CUSTOM SILL PER INTERIOR DOCUMENTS INTERIOR EXTERIOR 3X3 WOOD TRIM WITH SLOPED TOP TO DRAIN TRIM PER INTERIOR DOCUMENTS CONTINUOUS 1X4 HORIZONTAL FURRING STRIPS @ 2'-0" O.C. OVER 3D DRAINAGE MEDIUM AND AIR INFILTRATION BARRIER EXTERIOR INTERIOR BLOCKING WOOD TRIM LINE OF WINDOW JAMB BEYOND ICE & WATER SHIELD CONTINUOUS UNDER SILL SEALANT IN-FILL W/ EXPANDING SPRAY FOAM INSULATION AND SHIM AS REQ. STL. C-CHANNEL RE: STRUCT GRID LINE EXTERIOR INTERIOR (1) 1 3/4" X 5.5" LVL MICROLAMS 9/16" WOOD TRIM RE: SPEC SEALANT 3/8" GRID LINE 1/2" PLYWOOD FILLER ATTACHED TO DOOR FRAME SIDE OF HEAD ONLY 3/8" CUSTOM 4/4 WOOD JAMB EXTENSION 3/16" 3 7/8" 3/16" 5/8" X 5/8" WOOD TRIM IN-FILL W/ EXPANDING SPRAY FOAM INSULATION & SHIM ALUMINUM CLAD PANEL WINDOW RE: WINDOW SCHEDULE STUFFED IN INSULATION AND SHIM AS REQ'D SEE _ / A_._ FOR TYP. COPPER SHINGLE SIDING WALL ASSEMBLY 3D DRAINAGE MEDIUM LAPS OVER BUILDING PAPER LAPS OVER TOP OF FLASHING 1 1/2" MIN LAP WATERPROOF MEMBRANE OVER NAILING FLANGE AND CONTINUE UP UNDER FLASHING AND UNDER BUILDING PAPER 3X3 WOOD TRIM GRID LINE CUSTOM JAMB PER EXTENDED DEPTH INTERIOR EXTERIOR COPPER FLASHING HEADER RE: STRUCT. TRIM PER INTERIOR DOCUMENTS WINDOW RE: WINDOW SCHEDULE STUFFED IN INSULATION AND SHIM AS REQ'D SEE _ / A_._ FOR TYP. COPPER SHINGLE SIDING WALL ASSEMBLY LAP BUILDING PAPER OVER 1ST LAYER OF WATERPROOF MEMBRANE LAP 2ND LAYER OF WATERPROOF MEMBRANE OVER 1ST LAYER AND OVER 3D DRAINAGE MEDIUM AND OVER BUILDING PAPER GRID LINE INTERIOR EXTERIOR CUSTOM WOOD JAMB PER EXTENDED WIDTH LAP 1ST LAYER OF WATERPROOF MEMBRANE OVER SHEATHING AND OVER NAILING FLANGE SEALANT JOINT AND BACKER ROD 3X3 WOOD TRIM TRIM PER INTERIOR DOCUMENTS 2 3/8" WINDOW RE: WINDOW SCHEDULE WINDOW SET IN BED OF SEALANT SEE _ / A_._ FOR TYP. COPPER SHINGLE SIDING WALL ASSEMBLY LAP WATERPROOF MEMBRANE OVER 3D DRAINAGE MEDIUM OVER BLDG. PAPER AND UNDER WINDOW SILL GRID LINE CUSTOM SILL PER INTERIOR DOCUMENTS INTERIOR EXTERIOR 3X3 WOOD TRIM WITH SLOPED TOP TO DRAIN TRIM PER INTERIOR DOCUMENTS 2 3/8" EXTERIOR INTERIOR (1) 1 3/4" X 5.5" LVL MICROLAMS WOOD TRIM WINDOW JAMB BEYOND ICE & WATER SHIELD CONTINUOUS UNDER SILL @ UPPER WINDOW LAPS OVER DOOR FRAME SEALANT 3/8" GRID IN-FILL W/ EXPANDING SPRAY FOAM INSULATION AND SHIM AS REQ. 3/8" 2 1/2" PFSM CLAD PANEL RE:ELEVATIONS EXTERIOR INTERIOR (1) 1 3/4" X 5.5" LVL MICROLAMS WOOD TRIM SEALANT GRID SPRAY FOAM VOID & SHIM AS REQ. WOOD JAMB EXTENSION W/ WOOD TRIM PFSM CLAD PANEL RE: ELEVATIONS Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 3" = 1'-0" 10/12/2015 11:46:37 AM A8.1 WINDOW AND DOOR DETAILS AG HB REIMERS RESIDENCE 10/12/2015 3090 BOOTH CREEK DR. VAIL, CO TOV FINAL DRB SUBMITTAL No. Revision Date Revision Description 3" = 1'-0" 1 WINDOW HEAD DETAIL @ STONE VENEER 3" = 1'-0" 2 WINDOW JAMB DETAIL @ STONE VENEER 3" = 1'-0" 3 WINDOW SILL DETAIL @ STONE VENEER 3" = 1'-0" 4 WINDOW HEAD DETAIL @ WOOD SIDING 3" = 1'-0" 5 WINDOW JAMB DETAIL @ WOOD SIDING 3" = 1'-0" 6 WINDOW SILL DETAIL @ WOOD SIDING 3" = 1'-0" 10 WINDOW HEADER TO WINDOW SILL CONNECTION AT FRONT ENTRY 3" = 1'-0" 11 WINDOW JAMB TO WINDOW JAMB CONNECTION AT FRONT ENTRY 3" = 1'-0" 7 WINDOW HEAD DETAIL @ COPPER SHINGLES 3" = 1'-0" 8 WINDOW JAMB DETAIL @ COPPER SHINGLES 3" = 1'-0" 9 WINDOW SILL DETAIL @ COPPER SHINGLES 3" = 1'-0" 12 DOOR HEADER TO WINDOW SILL @ FRONT ENTRY 3" = 1'-0" 13 DOOR JAMB TO WINDOW JAMB @ FRONT ENTRY DRB APPROVED 11/4/2015 12:00:00 AM