Loading...
HomeMy WebLinkAboutDRB150487_A000 - COVER_1454361720.pdfScale Date Drawn By Checked By Project Number 10/12/2015 11:36:37 AM A000 COVER VAIL SPA CONDOMINIUMS - MEW/DW 09/18/2014 VSC14 710 W. LIONSHEAD CIRCLE No. Description Date VAIL SPA CONDOMINIUMS PROGRESS/ PRICING 10.02.2015 710 WEST LIONSHEAD CIRCLE, VAIL, COLORADO GENERAL NOTES: 1. DO NOT SCALE DRAWINGS. 2. VERIFY ALL DIMENSIONS, CONDITIONS, AND UTILITY LOCATIONS PRIOR TO BEGINNING ANY WORK OR ORDERING ANY MATERIALS. NOTIFY ARCHITECT OF ANY CONFLICTS OR DISCREPANCIES IN THE DOCUMENTS IMMEDIATELY. 3. AREAS OF CONFLICTS OR DISCREPANCIES MUST BE FULLY RESOLVED WITH WRITTEN APPROVAL FROM THE ARCHITECTS BEFORE CONSTRUCTION CONTINUES IN THESE PARTICULAR AREAS. 4. PLAN DIMENSIONS ARE TO FACE OF STUD, CENTERLINE OF STEEL, TIMBER, STUD COLUMNS, OR FACE OF CONCRETE UNLESS OTHERWISE NOTED. SECTION AND ELEVATION DIMENSIONS ARE TO TOP OF CONCRETE, TOP OF PLYWOOD, OR TOP OF WALL PLATES OR BEAMS UNLESS OTHERWISE NOTED. 5. PROVIDE ALL NECESSARY BLOCKING IN STUD WALLS AND CEILINGS. LOCATIONS INCLUDE BUT ARE NOT LIMITED TO CEILING AND WALL MOUNTED FIXTURES, TOILETS, TOILET ACCESSORIES, CABINETRY, COUNTERTOPS, SHELVES, CLOSET RODS AND FALSE BEAMS. 6. REFER TO FLOOR PLANS FOR DOOR LOCATIONS. REFER TO DOOR SCHEDULE FOR DOOR TYPES. 7. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS. REFER TO WINDOW SCHEDULE FOR WINDOW TYPES. 8. COORDINATE ALL ELECTRICAL AND MECHANICAL FIXTURES TO FIT WITHIN CEILING FLOOR AND WALL SPACES. VERIFY WITH ARCHITECT WHEN DIVERTING FROM DRAWINGS. 9. IN THE EVENT THAT ADDITIONAL DETAILS OR GUIDANCE IS NEEDED BY THE CONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE ARCHITECT. FAILURE TO GIVE 10 DAY NOTICE TO ARCHITECT SHALL NOT CONSTITUTE A DELAY IN THE PROJECT. 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SATISFYING ALL APPLICABLE CODES AND OBTAINING ALL PERMITS AND REQUIRED APPROVALS. THIS PROJECT IS GOVERNED BY THE UNIFORM BUILDING CODE 1997 EDITION. COMPLIANCE IS MANDATORY. THE CONSTRUCTION DOCUMENTS SHALL NOT PERMIT WORK THAT DOES NOT CONFORM TO ALL RELEVANT CODES INCLUDING IN UBC AND ALL LOCAL AND REGIONAL CODES. 11. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL FIELD COORDINATE AND OBTAIN APPROVALS FROM THE ARCHITECT/ENGINEER BEFORE ANY CUTTING, NOTCHING, OR DRILLING OF ANY CAST-IN-PLACE CONCRETE, STRUCTURAL FRAMING, OR ANY OTHER STRUCTURAL ELEMENTS WHICH MAY AFFECT THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION. 12. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING GRADES AND SCALE OUT THE BUILDING FOOTPRINT FOR OWNER AND ARCHITECT APPROVAL PRIOR TO BEGINNING ANY SITE WORK. 13. THE OWNER HAS BEEN ADVISED THAT DUE TO HARSH WINTER CONDITIONS, ROOF & DECK SURFACES MUST BE MAINTAINED REASONABLE FREE OF ICE & SNOW TO ENSURE MINIMAL PROBLEMS WITH THESE SURFACES. 14. SUBSTITUTIONS OF "EQUAL" PRODUCTS WILL BE ACCEPTABLE WITH ARCHITECT'S WRITTEN APPROVAL. 15. IT IS THE INTENT AND MEANING OF THESE DOCUMENTS THAT THE GENERAL CONTRACTOR AND EACH SUBCONTRACTOR PROVIDE ALL LABOR, MATERIALS TRANSPORTATION, SUPPLIES, EQUIPMENT, ETC. TO OBTAIN A COMPLETE JOB WITHIN THE RECOGNIZED STANDARDS OF THE INDUSTRY. 16. ALL CONSTRUCTION IS TO FIT WITHIN THE BUILDING ENVELOPE AND/OR OUTSIDE SETBACKS WITHOUT CREATING EASEMENTS. NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES. 17. THE GENERAL CONTRACTOR SHALL FIELD VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES. ALL UTILITIES SHALL BE LOCATED TO MINIMIZE EXCAVATION AND VEGETATION IMPACTS TO THE SITE. 18. THE GENERAL CONTRACTOR SHALL MINIMIZE THE LIMITS OF EXCAVATION AND TAKE ADEQUATE MEASURES TO PROTECT ALL VEGETATION BEYOND THE LIMITS OF EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE EXCAVATION. ALL AREAS OF DISTURBANCE SHALL BE RE-VEGETATED TO BLEND WITH THE NON-DISTURBED LANDSCAPE. 19. THE SOILS REPORT IS AVAILABLE FROM OWNER'S SOILS ENGINEER. 20. GENERAL CONTRACTOR SHALL VERIFY ALL SITE DEVELOPMENT WITH LANDSCAPE CONSTRUCTION DOCUMENTS. THE SITE PLAN IS FOR GRADING AND LANDSCAPE PLAN IS FOR LAYOUT; ANY DISCREPANCIES VERIFY WITH ARCHITECT. CODE: INTERNATIONAL BUILDING CODE 2015 ZONING: HIGH DENSITY MULTIPLE FAMILY DISTRICT OCCUPANCY CLASSIFICATION: TYPE R-2 CONSTRUCTION CLASSIFICATION: TYPE 1-A BUILDING FULLY SPRINKLED WITH AUTOMATIC ALARM SYSTEM PER IECC, BLOWER DOOR TEST IS REQUIRED PRIOR TO FINAL INSPECTION PROJECT SUMMARY: ARCHITECT: K.H. WEBB ARCHITECTS P.C. 710 WEST LIONSHEAD CIR., SUITE A VAIL, CO 81657 PH. 970-477-2990 Kyle@khwebb.com CONTACTS: KYLE H. WEBB PROJECT TEAM: SURVEYOR: EAGLE VALLEY SURVEYORS P.O. BOX 1230 EDWARDS, COLORADO 81632 PH. 970.949.1406 VICINITY MAP: VAIL SPA CONDOMINIUMS 710 W. LIONSHEAD CIRCLE VAIL, CO 81657 1 SOUTH PERSPECTIVE DRAWING INDEX SHEET # SHEET NAME 09.??.15 100% DD ARCHITECTURAL A000 COVER X A001 SITE PLAN X A101 LEVEL 1 PLAN X A102 LEVEL 2 PLAN X A103 LEVEL 3 PLAN X A104 LEVEL 1 FINISH PLAN A105 LEVEL 2 FINISH PLAN A106 LEVEL 3 FINISH PLAN A107 LEVEL 1 RCP A108 LEVEL 2 RCP A201 ELEVATIONS X A202 ELEVATIONS X A203 ELEVATIONS X A204 ELEVATIONS X A301 WALL SECTIONS X A302 WALL SECTIONS X A303 WALL SECTIONS X A304 WALL SECTIONS X A305 WALL SECTIONS A306 WALL SECTIONS A401 MAIN ENTRANCE/STAIR A402 MAIN ENTRANCE/STAIR DETAILS A403 COMMON AREAS A404 WOMEN'S LOCKER ROOM X A404a WOMEN'S LOCKER ROOM CONT. A405 MEN'S LOCKER ROOM A405a MEN'S LOCKER ROOM CONT. A406 LOCKER ROOM DETAILS A407 INDOOR/OUTDOOR POOL A408 LEVEL 2 RESTROOMS A409 LEVEL 2 RESTROOM DETAILS A410 ELEVATOR CAB A501 DETAILS A901 PERSPECTIVES X A902 PERSPECTIVES X 01 PROGRESS/PRICING 2 OCT 15 02 DRB REVIEW 12 OCT 15 DRB APPROVED 11/18/2015 12:00:00 AM