Loading...
HomeMy WebLinkAboutDRB150487_A001 - SITE_1454361720.pdfDN G H D E C B-1 B A 02.A K 01.A 01.K 01.H 14.1 14.2 10.7 10.8 10.9 10.10 10.11 10.12 DN 1 2 3 5 6 7 8 9 10 11 12 13 14 15 16 17 G H D E C B-1 B A RR REPLACE ALL BUILT-UP ROOFS, VENTS, CHIMNEYS, FLASHING. COMMON AREAS BY ASSOCIATION. UNIT A/C CONDENSER UNITS BY OWNER PRIVATE PATIOS TO MATCH CONC PAVERS AT ENTRY AND DRIVE, BY OWNER STANDING SEAM METAL SHED ROOFS AT STAIR TOWERS BY ASSOCIATION NEW SNOW MELTED POOL AND HOT TUB DECKS ALL LOW TERRACE WALLS AND POOL AREA WALLS: REPAIR AND CLAD WITH CEDAR SLATTING AND METAL CAPS COMMON AREA PAVING REPLACEMENT BY ASSOCIATION QQ PP NN NEW ROOF RAILINGS, ANCHORS, ETC. BY ASSOCIATION I F J K BB AA CC DD EE HH GG FF JJ KK LL MM Scale Date Drawn By Checked By Project Number 1/16" = 1'-0" 10/12/2015 11:37:03 AM A001 SITE PLAN VAIL SPA CONDOMINIUMS - WMC 09/18/2014 VSC14 710 W. LIONSHEAD CIRCLE 1/16" = 1'-0" 1 SITE PLAN No. Description Date 01 PROGRESS/PRICING 2 OCT 15 GENERAL PLAN NOTES 1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O. 2. FURNITURE IS NIC, U.N.O. 3. ALL BUILDING AREAS SHALL BE FULLY SPRINKLERED PER NFPA-13. SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES AND GARAGE AND OTHER UNCONDITIONED AREAS. 4. PARKING LEVEL SHALL BE FULLY SPRINKLERED PER NFPA-13. 5. COORDINATE LOCATION OF KNOX BOX WITH FIRE DEPT AND ARCH, RE: HW SCHEDULE 6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL BE COORDINATED WITH STRUCTURAL. 7. PENETRATIONS AT ROOF TOP UNITS & MAKE-UP AIR UNITS SHALL BE COORDINATED WITH MECHANICAL CONTRACTOR FOR SIZE AND LOCATION. 8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT PERPENDICULAR WALL SHALL BE 4" U.N.O. 9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES & GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL. BARRIER ON EXT. WHERE SIDING SHOWN). 10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE CONSTRUCTED ON A 5 1/2" x 6" CONC CURB, RE: X/A5.04. 11. PROVIDE ROOF HATCH ACCESS FROM CENTRAL STAIR TO ROOF, PER FIRE CODE 12. RE: SPECS FOR DOOR HARDWARE SETS. 13. RE: A8.50 FOR DOOR SCHEDULE. 14. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICAL TYPE 56E U.N.O., RE: A570 15. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM NOTED FROM FACE OF FINISH TO FACE OF FINISH. 16. ALL LOAD-BEARING STEEL COLUMNS SHALL BE 1-HOUR RATED PER 13/A570. 17. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES) TO BE 1-HR RATED RE: 18/A570. 18. RE: A505 FOR TYPICAL AND SPECIFIC FLOOR TRANSITIONS 19. RE: 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH FLOOR LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT BE LESS THAN 7 FEET (2134 MM). VEHICLE AND PEDESTRIAN AREAS ACCOMMODATING VAN-ACCESSIBLE PARKING REQUIRED BY SECTION 1106.5 SHALL CONFORM TO ICC A117.1. 8'-2" MIN. CLEAR HEIGHT 20. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS. 21. RE: A701-A703 FOR ENLARGED PLANS 22. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR RATING, WHEN PART OF PARTITION ASSEMBLY (REVISE?) 02 DRB REVIEW 12 OCT 1502 DRB REVIEW 12 OCT 15 DRB APPROVED 11/18/2015 12:00:00 AM