HomeMy WebLinkAboutDRB150487_A001 - SITE_1454361720.pdfDN
G H D E C
B-1
B A 02.A K 01.A
01.K
01.H
14.1
14.2
10.7
10.8
10.9 10.10
10.11
10.12
DN
1
2
3
5
6
7
8
9
10
11
12
13
14
15
16
17
G H D
E C B-1 B A
RR
REPLACE ALL BUILT-UP ROOFS, VENTS, CHIMNEYS, FLASHING. COMMON
AREAS BY ASSOCIATION. UNIT A/C CONDENSER UNITS BY OWNER
PRIVATE PATIOS TO MATCH CONC PAVERS AT ENTRY AND DRIVE, BY OWNER
STANDING SEAM METAL SHED ROOFS AT STAIR TOWERS BY
ASSOCIATION
NEW SNOW MELTED POOL AND HOT TUB DECKS
ALL LOW TERRACE WALLS AND POOL AREA WALLS: REPAIR
AND CLAD WITH CEDAR SLATTING AND METAL CAPS
COMMON AREA PAVING REPLACEMENT BY
ASSOCIATION
QQ
PP
NN
NEW ROOF RAILINGS, ANCHORS, ETC. BY ASSOCIATION
I F J K
BB
AA
CC
DD
EE
HH GG FF
JJ KK LL MM
Scale
Date
Drawn By
Checked By
Project Number
1/16" = 1'-0"
10/12/2015 11:37:03 AM
A001
SITE PLAN
VAIL SPA
CONDOMINIUMS
-
WMC
09/18/2014
VSC14
710 W. LIONSHEAD CIRCLE
1/16" = 1'-0"
1
SITE PLAN
No. Description Date
01 PROGRESS/PRICING 2 OCT 15
GENERAL PLAN NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O.
2. FURNITURE IS NIC, U.N.O.
3. ALL BUILDING AREAS SHALL BE FULLY SPRINKLERED PER
NFPA-13. SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT
BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D
BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES
AND GARAGE AND OTHER UNCONDITIONED AREAS.
4. PARKING LEVEL SHALL BE FULLY SPRINKLERED PER NFPA-13.
5. COORDINATE LOCATION OF KNOX BOX WITH FIRE DEPT AND
ARCH, RE: HW SCHEDULE
6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL
BE COORDINATED WITH STRUCTURAL.
7. PENETRATIONS AT ROOF TOP UNITS & MAKE-UP AIR UNITS SHALL
BE COORDINATED WITH MECHANICAL CONTRACTOR FOR SIZE
AND LOCATION.
8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT
PERPENDICULAR WALL SHALL BE 4" U.N.O.
9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES &
GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL.
BARRIER ON EXT. WHERE SIDING SHOWN).
10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE
CONSTRUCTED ON A 5 1/2" x 6" CONC CURB, RE: X/A5.04.
11. PROVIDE ROOF HATCH ACCESS FROM CENTRAL STAIR TO ROOF,
PER FIRE CODE
12. RE: SPECS FOR DOOR HARDWARE SETS.
13. RE: A8.50 FOR DOOR SCHEDULE.
14. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICAL TYPE 56E
U.N.O., RE: A570
15. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM
NOTED FROM FACE OF FINISH TO FACE OF FINISH.
16. ALL LOAD-BEARING STEEL COLUMNS SHALL BE 1-HOUR RATED
PER 13/A570.
17. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES) TO BE 1-HR
RATED RE: 18/A570.
18. RE: A505 FOR TYPICAL AND SPECIFIC FLOOR TRANSITIONS
19. RE: 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH
FLOOR LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS
SHALL NOT BE LESS THAN 7 FEET (2134 MM). VEHICLE AND
PEDESTRIAN AREAS ACCOMMODATING VAN-ACCESSIBLE
PARKING REQUIRED BY SECTION 1106.5 SHALL CONFORM TO ICC
A117.1. 8'-2" MIN. CLEAR HEIGHT
20. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS
TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS.
21. RE: A701-A703 FOR ENLARGED PLANS
22. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR
RATING, WHEN PART OF PARTITION ASSEMBLY (REVISE?)
02 DRB REVIEW 12 OCT 1502 DRB REVIEW 12 OCT 15
DRB
APPROVED
11/18/2015
12:00:00 AM