HomeMy WebLinkAboutDRB150487_A101 - LEVEL 1_1454361720.pdfDN
UP
DN
UP
A204
A202
A203
1
A201 2
1
1
1
2
3
5
6
7 7
8
9
10
11
12
13
14
16
G H
D
D E
C
C
B-1
B-1
B
B
A
A
A203
2
RR
NEW ADA POOL LIFT
NEW ADA POOL LIFT
NEW ACCESS RAMP
ADA COMPLIANT LOCKER ROOMS, SHOWERS, AND TOILETS,
SEE ENLARGED PLAN
A201
1
A202
2
A204
2
QQ
PP
NN
CEDAR SLATING AT ALL GRADE SITE WALLS WITH
METAL CAP FLASHING
EXISTING CONCRETE POOL DECK AND
STAIRS TO BE REMOVED. PAVERS ON
SAND BED WITH SNOWMELT TO
REPLACE OLD DECK
NEW SOD AREA
NEW POOL SITE WALLS W/ CEDAR SLATS AND
METAL CAP FLASHING
NEW BBQ AREA
WITH EXPOSED
TIMBER TRELLIS
AND METAL ROOF
EXISTING
FIREPIT
EXISTING GRASS
AREA
NEW ACCESSIBLE POOL ENTRY
GATE AND PATH
I F J K
BB
AA
CC
DD
EE
HH GG FF
JJ KK LL MM
9' - 0"
20' - 0" 20' - 0"
20' - 0"
23' - 0"
23' - 0"
23' - 0"
23' - 0"
25' - 4"
23' - 0"
26' - 8" 5' - 0" 12' - 0" 16' - 0" 25' - 6" 25' - 6" 19' - 7" 12' - 8 3/4" 14' - 10 1/4" 5' - 0" 12' - 0"
174' - 10"
12' - 0"5' - 0"
23' - 0"
23' - 0"
22' - 11 3/4"
12' - 0"5' - 0"14' - 10 1/4"12' - 8 3/4"
13' - 0"23' - 0"
5' - 5"
A410
4
2
5 3
REPAIR POOL AND HOT TUB AS NEEDED
IN BASIN; NEW POOL COPING
THROUGHOUT.
NEW ENTRY ROOF AND VESTIBULE
Scale
Date
Drawn By
Checked By
Project Number
1/16" = 1'-0"
10/12/2015 11:37:08 AM
A101
LEVEL 1 PLAN
VAIL SPA
CONDOMINIUMS
-
wmc
09/18/2014
VSC14
710 W. LIONSHEAD CIRCLE
1/16" = 1'-0"
1
LEVEL 1 FLOOR PLAN
No. Description Date
01 PROGRESS/PRICING 2 OCT 1501
PROGRESS/PRICING
2 OCT 15
GENERAL PLAN NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O.
2. FURNITURE IS NIC, U.N.O.
3. ALL BUILDING AREAS SHALL BE FULLY SPRINKLERED PER
NFPA-13. SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT
BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D
BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES
AND GARAGE AND OTHER UNCONDITIONED AREAS.
4. PARKING LEVEL SHALL BE FULLY SPRINKLERED PER NFPA-13.
5. COORDINATE LOCATION OF KNOX BOX WITH FIRE DEPT AND
ARCH, RE: HW SCHEDULE
6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL
BE COORDINATED WITH STRUCTURAL.
7. PENETRATIONS AT ROOF TOP UNITS & MAKE-UP AIR UNITS SHALL
BE COORDINATED WITH MECHANICAL CONTRACTOR FOR SIZE
AND LOCATION.
8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT
PERPENDICULAR WALL SHALL BE 4" U.N.O.
9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES &
GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL.
BARRIER ON EXT. WHERE SIDING SHOWN).
10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE
CONSTRUCTED ON A 5 1/2" x 6" CONC CURB, RE: X/A5.04.
11. PROVIDE ROOF HATCH ACCESS FROM CENTRAL STAIR TO ROOF,
PER FIRE CODE
12. RE: SPECS FOR DOOR HARDWARE SETS.
13. RE: A8.50 FOR DOOR SCHEDULE.
14. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICAL TYPE 56E
U.N.O., RE: A570
15. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM
NOTED FROM FACE OF FINISH TO FACE OF FINISH.
16. ALL LOAD-BEARING STEEL COLUMNS SHALL BE 1-HOUR RATED
PER 13/A570.
17. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES) TO BE 1-HR
RATED RE: 18/A570.
18. RE: A505 FOR TYPICAL AND SPECIFIC FLOOR TRANSITIONS
19. RE: 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH
FLOOR LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS
SHALL NOT BE LESS THAN 7 FEET (2134 MM). VEHICLE AND
PEDESTRIAN AREAS ACCOMMODATING VAN-ACCESSIBLE
PARKING REQUIRED BY SECTION 1106.5 SHALL CONFORM TO ICC
A117.1. 8'-2" MIN. CLEAR HEIGHT
20. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS
TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS.
21. RE: A701-A703 FOR ENLARGED PLANS
22. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR
RATING, WHEN PART OF PARTITION ASSEMBLY (REVISE?)
02 DRB REVIEW 12 OCT 15
DRB
APPROVED
11/18/2015
12:00:00 AM