Loading...
HomeMy WebLinkAboutDRB150487_A102 - LEVEL 2_1454361720.pdfDN DN DN A202 A203 1 A201 2 1 1 2 3 5 6 7 7 8 9 10 11 12 13 14 15 16 17 G G H D D E E C C B-1 B-1 B B A A 5' - 7" A203 2 RR A201 1 A202 2 A204 2 A408 1 REPLACE (5)INSWING DOORS W/ (2) SLIDING GLASS DOORS, SEE WINDOW SCHEDULE, TYP. REPLACE INSWING PATIO DRS W/SLIDERS, SEE SCHED. QQ PP NN **REPLACE ALL WINDOWS AND DOORS. PRIVATE UNIT WINDOWS AND DOORS BY OWNER ALL WOOD SIDING TO BE REPLACED WITH 3 COAT STUCCO SYSTEM AND CEMENTIOUS TRIM ALL BAY WINDOWS TO GET COPPER CLADDING (ALT: PREFINISHED METAL PANELS), SEE ELEVATIONS AND PERSPECTIVES FOR LOCATIONS PRECAST CONCRETE WALLS INTEGRAL COLOR SKIMCOATED STUCCO STAIR TOWERS CLAD IN CORRUGATED CORTEN STEEL PANELS ALT.**GLU LAM BEAMS TO RECEIVE COPPER PANEL WRAP PRECAST CONCRETE WALLS CLAD WITH HORIZONTAL 8" CEDAR SLAT SIDING STAIR TOWERS CLAD IN CORRUGATED CORTEN WESTERN RIB STEEL PANELS A301 1 A303 4 I F F J K BB AA CC DD EE HH GG FF JJ KK A304 2 A305 2 12' - 0"5' - 0"14' - 10 1/4"12' - 8 3/4" 3 A301 2 A301 3 A303 A204 1 3 A304 NEW ENTRY VESTIBULE BETWEEN GUEST GARAGE AND LEVEL 2 LOUNGE STAIR TOWERS CLAD IN CORRUGATED CORTEN WESTERN RIB STEEL PANELS ALL CAST-IN-PLACE CONCRETE TO BE PATCHED AND REPAIRED WITH 2 PROCESS EPOXY AND INTEGRAL COLOR SKIMCOAT STUCCO REPLACE ALL SLOPED GLASS AND CURTAIN WALL SYSTEM Scale Date Drawn By Checked By Project Number 1/16" = 1'-0" 10/12/2015 11:37:11 AM A102 LEVEL 2 PLAN VAIL SPA CONDOMINIUMS - wmc 09/18/2014 VSC14 710 W. LIONSHEAD CIRCLE 1/16" = 1'-0" 1 LEVEL 2 FLOOR PLAN No. Description Date 01 PROGRESS/PRICING 2 OCT 15 GENERAL PLAN NOTES 1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O. 2. FURNITURE IS NIC, U.N.O. 3. ALL BUILDING AREAS SHALL BE FULLY SPRINKLERED PER NFPA-13. SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES AND GARAGE AND OTHER UNCONDITIONED AREAS. 4. PARKING LEVEL SHALL BE FULLY SPRINKLERED PER NFPA-13. 5. COORDINATE LOCATION OF KNOX BOX WITH FIRE DEPT AND ARCH, RE: HW SCHEDULE 6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL BE COORDINATED WITH STRUCTURAL. 7. PENETRATIONS AT ROOF TOP UNITS & MAKE-UP AIR UNITS SHALL BE COORDINATED WITH MECHANICAL CONTRACTOR FOR SIZE AND LOCATION. 8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT PERPENDICULAR WALL SHALL BE 4" U.N.O. 9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES & GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL. BARRIER ON EXT. WHERE SIDING SHOWN). 10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE CONSTRUCTED ON A 5 1/2" x 6" CONC CURB, RE: X/A5.04. 11. PROVIDE ROOF HATCH ACCESS FROM CENTRAL STAIR TO ROOF, PER FIRE CODE 12. RE: SPECS FOR DOOR HARDWARE SETS. 13. RE: A8.50 FOR DOOR SCHEDULE. 14. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICAL TYPE 56E U.N.O., RE: A570 15. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM NOTED FROM FACE OF FINISH TO FACE OF FINISH. 16. ALL LOAD-BEARING STEEL COLUMNS SHALL BE 1-HOUR RATED PER 13/A570. 17. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES) TO BE 1-HR RATED RE: 18/A570. 18. RE: A505 FOR TYPICAL AND SPECIFIC FLOOR TRANSITIONS 19. RE: 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH FLOOR LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS SHALL NOT BE LESS THAN 7 FEET (2134 MM). VEHICLE AND PEDESTRIAN AREAS ACCOMMODATING VAN-ACCESSIBLE PARKING REQUIRED BY SECTION 1106.5 SHALL CONFORM TO ICC A117.1. 8'-2" MIN. CLEAR HEIGHT 20. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS. 21. RE: A701-A703 FOR ENLARGED PLANS 22. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR RATING, WHEN PART OF PARTITION ASSEMBLY (REVISE?) 02 DRB REVIEW 12 OCT 15 DRB APPROVED 11/18/2015 12:00:00 AM