HomeMy WebLinkAboutDRB150487_A102 - LEVEL 2_1454361720.pdfDN
DN
DN
A202
A203
1
A201 2
1
1
2
3
5
6
7 7
8
9
10
11
12
13
14
15
16 17
G
G H
D
D
E
E
C
C
B-1
B-1
B
B
A
A
5' - 7"
A203
2
RR
A201
1
A202
2
A204
2
A408
1
REPLACE (5)INSWING DOORS W/ (2)
SLIDING GLASS DOORS, SEE
WINDOW SCHEDULE, TYP.
REPLACE INSWING PATIO DRS
W/SLIDERS, SEE SCHED.
QQ
PP
NN
**REPLACE ALL WINDOWS AND DOORS.
PRIVATE UNIT WINDOWS AND DOORS BY
OWNER
ALL WOOD SIDING TO BE
REPLACED WITH 3 COAT
STUCCO SYSTEM AND
CEMENTIOUS TRIM
ALL BAY WINDOWS TO GET COPPER
CLADDING (ALT: PREFINISHED
METAL PANELS), SEE ELEVATIONS
AND PERSPECTIVES FOR
LOCATIONS
PRECAST CONCRETE WALLS
INTEGRAL COLOR SKIMCOATED
STUCCO
STAIR TOWERS CLAD IN
CORRUGATED CORTEN STEEL
PANELS
ALT.**GLU LAM BEAMS TO
RECEIVE COPPER PANEL
WRAP
PRECAST CONCRETE WALLS
CLAD WITH HORIZONTAL 8"
CEDAR SLAT SIDING
STAIR TOWERS CLAD IN
CORRUGATED CORTEN
WESTERN RIB STEEL
PANELS
A301
1
A303
4
I
F
F J K
BB
AA
CC
DD
EE
HH
GG
FF
JJ
KK
A304
2
A305
2
12' - 0"5' - 0"14' - 10 1/4"12' - 8 3/4"
3
A301
2
A301
3
A303
A204
1
3
A304
NEW ENTRY VESTIBULE
BETWEEN GUEST
GARAGE AND LEVEL 2
LOUNGE
STAIR TOWERS CLAD IN
CORRUGATED CORTEN
WESTERN RIB STEEL
PANELS
ALL CAST-IN-PLACE CONCRETE TO
BE PATCHED AND REPAIRED WITH
2 PROCESS EPOXY AND INTEGRAL
COLOR SKIMCOAT STUCCO
REPLACE ALL SLOPED GLASS AND
CURTAIN WALL SYSTEM
Scale
Date
Drawn By
Checked By
Project Number
1/16" = 1'-0"
10/12/2015 11:37:11 AM
A102
LEVEL 2 PLAN
VAIL SPA
CONDOMINIUMS
-
wmc
09/18/2014
VSC14
710 W. LIONSHEAD CIRCLE
1/16" = 1'-0"
1
LEVEL 2 FLOOR PLAN
No. Description Date
01 PROGRESS/PRICING 2 OCT 15
GENERAL PLAN NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O.
2. FURNITURE IS NIC, U.N.O.
3. ALL BUILDING AREAS SHALL BE FULLY SPRINKLERED PER
NFPA-13. SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT
BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D
BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES
AND GARAGE AND OTHER UNCONDITIONED AREAS.
4. PARKING LEVEL SHALL BE FULLY SPRINKLERED PER NFPA-13.
5. COORDINATE LOCATION OF KNOX BOX WITH FIRE DEPT AND
ARCH, RE: HW SCHEDULE
6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL
BE COORDINATED WITH STRUCTURAL.
7. PENETRATIONS AT ROOF TOP UNITS & MAKE-UP AIR UNITS SHALL
BE COORDINATED WITH MECHANICAL CONTRACTOR FOR SIZE
AND LOCATION.
8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT
PERPENDICULAR WALL SHALL BE 4" U.N.O.
9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES &
GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL.
BARRIER ON EXT. WHERE SIDING SHOWN).
10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE
CONSTRUCTED ON A 5 1/2" x 6" CONC CURB, RE: X/A5.04.
11. PROVIDE ROOF HATCH ACCESS FROM CENTRAL STAIR TO ROOF,
PER FIRE CODE
12. RE: SPECS FOR DOOR HARDWARE SETS.
13. RE: A8.50 FOR DOOR SCHEDULE.
14. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICAL TYPE 56E
U.N.O., RE: A570
15. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM
NOTED FROM FACE OF FINISH TO FACE OF FINISH.
16. ALL LOAD-BEARING STEEL COLUMNS SHALL BE 1-HOUR RATED
PER 13/A570.
17. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES) TO BE 1-HR
RATED RE: 18/A570.
18. RE: A505 FOR TYPICAL AND SPECIFIC FLOOR TRANSITIONS
19. RE: 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH
FLOOR LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS
SHALL NOT BE LESS THAN 7 FEET (2134 MM). VEHICLE AND
PEDESTRIAN AREAS ACCOMMODATING VAN-ACCESSIBLE
PARKING REQUIRED BY SECTION 1106.5 SHALL CONFORM TO ICC
A117.1. 8'-2" MIN. CLEAR HEIGHT
20. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS
TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS.
21. RE: A701-A703 FOR ENLARGED PLANS
22. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR
RATING, WHEN PART OF PARTITION ASSEMBLY (REVISE?)
02 DRB REVIEW 12 OCT 15
DRB
APPROVED
11/18/2015
12:00:00 AM