HomeMy WebLinkAboutDRB150487_A103 - LEVEL 3_1454361720.pdfUP
A204
A202
A203
1
A201 2
1
1
1
2
3
5
6
7
8
9
10
11
12
13
14
15
16
17
G H D E C B-1 B A
RR
ALL ABOVE GRADE PRIVATE PATIOS WITH NEW TREX DECKING,
PATCH/REPLACE MEMBRANE ROOFING, AND NEW CURB FLASHING, BY
OWNER. NEW STUCCO SOFFIT BOARD FOR CEILINGS; RAILINGS TO BE
REFINISHED POWDER COAT BY ASSOCIATION, TYP.
A202
2
A204
2
QQ
PP
NN
EGRESS STAIR TO BE REFURBISHED: REPAIR/REPLACE
CONCRETE TREADS AND LANDINGS, RAILINGS, AND STEEL
STRUCTURE. PERFORATED METAL SCREEN AT STAIR SIDES;
VERTICAL CORTEN SIDING AT CURVED LANDINGS. ONE-WAY
SECURITY GATE AT LEVEL 3 EGRESS TO BE ADDED.
REPLACE WOOD LAP SIDING AT ELEVATED DECK WALLS WITH CONC. BD. LAP SIDING
CORRUGATED CORTEN SIDING AT STAIR TOWERS
INTEGRAL COLOR STUCCO SKINCOAT ON PRE-CAST CONC WALLS.
A301
1
A303
4
I F J K
BB
AA
CC
DD
EE
HH GG FF
JJ KK LL MM
A302
2
A304
2
A306
2
A306
4
A305
2
A305
4
A303
2
COPPER (ALT: PRE-FINISHED PAINTED METAL) SHEET PANEL
CLADDING FOR ALL BAY WINDOWS
COPPER (ALT: PRE-FINISHED
PAINTED METAL) SHEET PANEL
CLADDING FOR ALL BAY
WINDOWS
COPPER (ALT: PRE-
FINISHED PAINTED
METAL) SHEET PANEL
CLADDING FOR
REMAINING EXPOSED
GLULAM BEAMS AND
SHADING
STRUCTURES
REPLACE WOOD DECKING WITH TREX (SIM) AT ALL BALCONIES AND DECKS
Scale
Date
Drawn By
Checked By
Project Number
1/16" = 1'-0"
10/12/2015 11:37:14 AM
A103
LEVEL 3 PLAN
VAIL SPA
CONDOMINIUMS
-
wmc
09/18/2014
VSC14
710 W. LIONSHEAD CIRCLE
1/16" = 1'-0"
1
LEVEL 3 FLOOR PLAN
No. Description Date
01 PROGRESS/PRICING 2 OCT 15
GENERAL PLAN NOTES
1. ALL DIMENSIONS ARE TO FACE OF STUD U.N.O.
2. FURNITURE IS NIC, U.N.O.
3. ALL BUILDING AREAS SHALL BE FULLY SPRINKLERED PER
NFPA-13. SPRINKLER PROTECTION SHALL BE PROVIDED FOR EXT
BALCONIES AND IN ROOF TRUSSES AND OTHER SPACES REQ'D
BY CODE. PROVIDE A DRY OR GLYCOL SYSTEM FOR RF TRUSSES
AND GARAGE AND OTHER UNCONDITIONED AREAS.
4. PARKING LEVEL SHALL BE FULLY SPRINKLERED PER NFPA-13.
5. COORDINATE LOCATION OF KNOX BOX WITH FIRE DEPT AND
ARCH, RE: HW SCHEDULE
6. PENETRATIONS AT DOUBLE-T AND TOPPING GARAGE LID SHALL
BE COORDINATED WITH STRUCTURAL.
7. PENETRATIONS AT ROOF TOP UNITS & MAKE-UP AIR UNITS SHALL
BE COORDINATED WITH MECHANICAL CONTRACTOR FOR SIZE
AND LOCATION.
8. DIM FROM EDGE OF DOOR FRAME TO EDGE OF ADJACENT
PERPENDICULAR WALL SHALL BE 4" U.N.O.
9. DRYWALL PART'NS BTWN CONDITIONED OCCUPIED SPACES &
GARAGE SHALL HAVE VAPOR BARRIER ON WARM SIDE (AIR INFIL.
BARRIER ON EXT. WHERE SIDING SHOWN).
10. ALL PART'NS IN OR ADJACENT TO PARKING GARAGE TO BE
CONSTRUCTED ON A 5 1/2" x 6" CONC CURB, RE: X/A5.04.
11. PROVIDE ROOF HATCH ACCESS FROM CENTRAL STAIR TO ROOF,
PER FIRE CODE
12. RE: SPECS FOR DOOR HARDWARE SETS.
13. RE: A8.50 FOR DOOR SCHEDULE.
14. ALL CORRIDOR/PARTITIONS SHALL BE ACOUSTICAL TYPE 56E
U.N.O., RE: A570
15. WHERE "CLEAR" IS CALLED OUT ON A DIMENSION, PROVIDE DIM
NOTED FROM FACE OF FINISH TO FACE OF FINISH.
16. ALL LOAD-BEARING STEEL COLUMNS SHALL BE 1-HOUR RATED
PER 13/A570.
17. ALL STRUCT STL BEAMS (EXCEPT AT BALCONIES) TO BE 1-HR
RATED RE: 18/A570.
18. RE: A505 FOR TYPICAL AND SPECIFIC FLOOR TRANSITIONS
19. RE: 406.2.2, IBC. CLEAR HEIGHT. THE CLEAR HEIGHT OF EACH
FLOOR LEVEL IN VEHICLE AND PEDESTRIAN TRAFFIC AREAS
SHALL NOT BE LESS THAN 7 FEET (2134 MM). VEHICLE AND
PEDESTRIAN AREAS ACCOMMODATING VAN-ACCESSIBLE
PARKING REQUIRED BY SECTION 1106.5 SHALL CONFORM TO ICC
A117.1. 8'-2" MIN. CLEAR HEIGHT
20. PROVIDE PRECAST SPLASH BLOCK @ ALL DOWNSPOUTS
TERMINATING IN LANDSCAPE OR ON FLAT MEMBRANE ROOFS.
21. RE: A701-A703 FOR ENLARGED PLANS
22. ALL COLUMNS SHALL BE INDIVIDUALLY PROTECTED FOR 1-HR
RATING, WHEN PART OF PARTITION ASSEMBLY (REVISE?)
02 DRB REVIEW 12 OCT 15
DRB
APPROVED
11/18/2015
12:00:00 AM