HomeMy WebLinkAboutDRB150550_A000.2_1452029100.pdf°
±
W/
<
Room name
101
ELEVATION
A101
1
SIM
100'-0"
SPOT ELEVATION
1
A101
SIM
DETAIL NUMBER
SHEET WHERE SHOWN
SECTION LETTER
SHEET WHERE SHOWN
DETAIL DESIGNATOR
BUILDING SECTION DESIGNATOR
1
101
DOOR DESIGNATOR
1i
WINDOW DESIGNATOR
0
GRID LINE
1i WALL TYPE
1
ADDENDUM
REVISED AREA
OF DRAWING
LEVEL INDICATOR
NAME
INTERIOR ELEVATION DESIGNATOR
A601
1 ELEVATION NUMBER
SHEET NUMBER
DOOR NUMBER
ROOM NUMBER
ROOM NUMBER
EXTERIOR ELEVATION DESIGNATOR
A301
1 ELEVATION NUMBER
SHEET NUMBER
00 00 00
CONSTRUCTION
SPECIFICATION INSTITUTE
SECTION NUMBER - REFER TO
PROJECT MANUAL FOR
PRODUCT SPECIFICATION
4' - 5"
FACE OF STRUCTURE TO FACE
OF STRUCTURE
VAIL VALLEY DRIVE
A
B
E
F F
UNIT B-102
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
600 VAIL
VALLEY
DRIVE,
BUILDING B
VAIL, CO 816578
A000.2
COVER SHEET
NORTHWOODS
UNIT
B-102
Project
#1523
08.21.15
08/21/15
DRB APPROVAL
STANDARD ABBREVIATIONS
MISC. ABBREVIATIONS
ROUND
WITH
DEGREES
PLUS OR MINUS
PROPERTY LINE
ANGLE
CENTER LINE
DRAWING CONVENTIONS
MATERIAL SYMBOLS
COMPACTED BACKFILL
STONE PAVERS
C.I.P. CONCRETE
BATT INSULATION
STONE
GRAVEL
NEW WALL
STEEL
RIGID INSULATION
CONCRETE TOPPING
LUMBER
EXISTING WALL
PARTICLE BOARD
CMU
GROUND LINE
ADMINISTRATIVE INFO.
BUILDING CODE SUMMARY
LEGAL DESCRIPTION OF PROPERTY:
BUILDING B PK BP-7&8,BS-9&11 SUBDIVISION: NORTHWOODS CONDOMINIUMS BLDG B UNIT: B-2
ZONING ANALYSIS
WOOD
PLYWOOD
VICINITY MAP
GENERAL DRAWING NOTES:
1.
2.
3.
STONE
STUCCO
WOOD SIDING
RWC RAIN WATER CONDUCTOR
S SOUTH
SC SOLID CORE
SCD SEAT COVER DISPENSER
SCHED SCHEDULE
SD SOAP DISPENSER
SECT SECTION
SF SQUARE FEET
SGLT STRUCTURAL GLU-LAM TIMBER
SHLVS SHELVES
SHR SHOWER
SHT SHEET
SHTG SHEATHING
SIM SIMILAR
SPEC SPECIFICATION(S)
SQ SQUARE
SR SINK RECEPTACLE
SS STAINLESS STEEL
SSK SERVICE SINK
SST STAINLESS STEEL
ST STAIN
STA STATION
STD STANDARD
STL STEEL
STO STORAGE
STRUCT STRUCTURE or STRUCTURAL
SUSP SUSPEND(ED)
SV SHEET VINYL
SYM SYMMETRICAL
SYS SYSTEM
T TREADS
T&B TOP AND BOTTOM
T&G TONGUE AND GROOVE
TB TOWEL BAR
TEL TELEPHONE
THK THICK or THICKNESS
THR THRESHOLD
THRU THROUGH
TO TOP OF
TOC TOP OF CONCRETE
TOV TOWN OF VAIL
TOW TOP OF WALL
TPH TOILET PAPER HOLDER
TPTN TOILET PARTITION
TV TELEVISION
TYP TYPICAL
UL UNDERWRITER'S LABORATORY
UNF UNFINISHED
UON UNLESS OTHERWISE NOTED
UOS UNLESS OTHERWISE SPECIFIED
UR URINAL
V VACUUM
VB VAPOR BARRIER
VCP VITRIFIED CLAY PIPE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIN VINYL
VTR VENT TO ROOF
VWC VINYL WALL COVERING
W WASHER
W/ WITH
W/O WITHOUT
WATER-RES WATER RESISTANT
WB WASTE BASKET
WC WATER CLOSET
WD WOOD
WF WIDE FLANGE
WIN WINDOW
WP WATERPROOF(ING)
WPT WORKING POINT
WSCT WAINSCOT
WWF WELDED WIRE FABRIC
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LT LIGHT
LTL LINTEL
LTWT LIGHTWEIGHT
LVL LEVEL
LVR LOUVER
M MASTER
MACH MACHINE
MAS MASONRY
MAT MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL and
PLUMBING
MFGR MANUFACTURER
MH MAN HOLE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MMB MEMBRANE
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
MUL MULLION
MW MICROWAVE
(N) NEW
N NORTH
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFF OFFICE
OH OPPOSITE HAND
OPG OPENING
OPP OPPOSITE
OTO OUTSIDE-TO-OUTSIDE
PAC PREVIOUSLY AWARDED
CONTRACT
PARTN PARTITION
PFB PREFABRICATED
PH PHONE
PL PLATE
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLNK PLANK
PLWD PLYWOOD
PNL PANEL
PNT PAINT
PNTD PAINTED
PORC PORCELAIN
PR PROPOSAL REQUEST
PR PAIR
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PTD PAPER TOWEL
DISPENSER/RECEPTACLE
PV PAVEMENT
QT QUARRY TILE
R RISERS
RAD RADIUS
RD ROOF DRAIN
RE REFER TO or REFERENCE
REC RECESS(ED)
REF REFRIGERATOR or REFRIGERATED
REINF REINFORCED
REQ'D REQUIRED
RES RESISTANT
RESIL RESILIENT
RET RETAINING
REV REVISE, REVISED or REVISION
RF RESILIENT FLOORING
RFG ROOFING
RFL REFLECTED
RL RAIN LEADER
RM ROOM
RO ROUGH OPENING
ROD ROOF OVERFLOW DRAIN
RS ROUGH SAWN
ELEV ELEVATOR
EM EMERGENCY OUTLET
EMER EMERGENCY
ENG ENGINEER
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FAS FASTEN(ER)
FBO FURNITURE BY OWNER
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFE FINISH FLOOR ELEVATION
FFL FINISHED FLOOR LINE
FHC FIRE HOSE CABINET
FIN FINISH(ED)
FIX FIXTURE
FLG FLASHING
FLR FLOOR(ING)
FLUOR FLUORESCENT
FPHB FREEZE PROOF HOSE BIB
FR FIRE RATED
FREZ FREEZER
FRM FRAME
FRP FIBERGLASS REINFORCED
PANEL(ING)
FRT FIRE RETARDANT TREATED
FT FEET
FTG FOOTING
FURR FURRING
FUT FUTURE
FV FIELD VERIFY
GA GAUGE
GALV GLAVANIZED
GB GRAB BAR
GCMU GLAZED CONCRETE MASONRY
UNIT(S)
GD GRADE
GEN GENERAL
GFP GAS FIRE PLACE
GI GALVINIZED IRON
GL GLASS
GND GROUND
GRT GROUT
GYP GYPSUM WALL BOARD
HB HOSE BIB
HC HOLLOW CORE
HD HEAD
HDCP HANDICAP(PED)
HDRL HAND RAIL
HDWD HARDWOOD
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HTR HEATER
HVAC HEATING, VENTILATION and AIR
CONDITIONING
IBC INTERNATIONAL BUILDING CODE
or INSTALLED BY CONTRACTOR
ID INSIDE DIAMETER
IN INCH
INFO INFORMATION
INSUL INSULATION or INSULATED
INT INTERIOR
INTX INTERSECTION
INV INVERT
JAN JANITOR
JB JUNCTION BOX
JT JOINT
K.D. KNOCKDOWN
K.O. KNOCKOUT
KIT KITCHEN
KPL KICK PLATE
LAB LABORATORY
LAM LAMINATE
LAV LAVATORY
LBL LABEL
LIN LINEN
LKR LOCKER
ABV ABOVE
ACOUS ACCOUSTICAL
ACT ACCOUSTICAL CEILING TILE
ADD ADDENDUM
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AG AGGREGATE
AL ALUMINUM
ALT ALTERNATE
ANCH ANCHOR
APPROX APPROXIMATELY
APSH ASPHALT
ARCH ARCHITECTURAL
ASI ARCHITECT'S SUPPLEMENTAL
INSTRUCTIONS
ATTEN ATTENUATION
AUTO AUTOMATIC
BD BOARD
BDRM BEDROOM
BEL BELOW
BET BETWEEN
BKT BRACKET
BLDG BUILDING
BLK BLOCK
BLR BOILER
BM BEAM
BO BY OWNER
BOF BY OWNER, FUTURE
BOT BOTTOM
BOW BOTTOM OF WALL
BRG BEARNING
BSMT BASEMENT
CAB CABINET
CATV CABLE TELEVISION
CB CATCH BASIN
CCD CONSTRUCTION CHANGE
DIRECTIVE
CCTV CLOSED CIRCUIT TELEVISION
CEM CEMENT
CER CERAMIC
CFL COUNTERFLASHING
CG CORNER GUARD
CIP CAST IN PLACE
CJ CONTROL JOINT
CK CAULK(ING)
CL CENTERLINE
CLG CEILING
CLL CONTRACT LIMIT LINE
CLOS CLOSET
CLR CLEARANCE
CMU CONCRETE MASONRY UNIT
CNTR COUNTER
CO CLEAN OUT
COL COLUMN
CON CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACT(OR)
CORR CORRIDOR
CPT CARPET
CT CERAMIC TILE
CTR CENTER
CTSK COUNTERSINK
D DRYER
DBL DOUBLE
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DR DRAIN
DS DOWNSPOUT
DW DISHWASHER
DWG DRAWING
DWR DRAWER
E EAST
EA EACH
EH EXHAUST FAN
EJ EXPANSION JOINT
EL ELEVATION
ELECT ELECTRICAL
BUILDING CODE: 2012 IBC
MECHANICAL CODE: 2009 IMC
2009 INTERNATIONAL FUEL GAS
CODE
2009 INTERNATIONAL FIRE CODE
2009 INTERNATIONAL ENERGY
CONSERVATION CODE
ELECTRICAL CODE: 2008 NEC
PLUMBING CODE: 2009 IPC
ACCESSABILITY STANDARDS: 2003 ICC/ANSI A117.1
CURRENT ZONING: SDD #2
CONSTRUCTION TYPE: III-A
NUMBER OF STORIES: 5
OCCUPANCY GROUP: R-2
REQUIRED/ALLOWABLE PROPOSED
SITE COVERAGE:
MAXIMUM HEIGHT:
GROSS RESIDENTIAL FLOOR AREA:
EMPLOYEE HOUSING UNIT:
DWELLING UNITS:
PARKING:
LANDSCAPE AREA:
SHEET # SHEET NAME BY
DRB
SUBMITTAL
BLDG
PERMIT
A000.2 COVER SHEET PA 08.21.15
A201.2 LEVEL 1 FLOOR PLAN PROPOSED PA 08.21.15
A202.2 LEVEL 2 FLOOR PLAN PROPOSED PA 08.21.15
A301.2 NORTH ELEVATION PROPOSED PA 08.21.15
A302.2 EAST & WEST ELEVATIONS PROPOSED PA 08.21.15
A303.2 3D VIEWS PROPOSED PA 08.21.15
EX201.2 EXST LEVEL 1 FLOOR PLAN PA 08.21.15
EX202.2 EXIST LEVEL 2 FLOOR PLAN PA 08.21.15
EX301.2 EXIST NORTH ELEVATION PA 08.21.15
EX302.2 EXIST EAST & WEST ELEVATIONS PA 08.21.15
EX303.2 EXIST 3D VIEWS PA 08.21.15
PROJECT DIRECTORY
STRUCTURAL ENGINEER: KRM CONSULTANTS, INC.
KIM MCGHEE
PO BOX 4572
VAIL, COLORADO 81658
P: 970.949.9391
F: 970.949.1577
E: KRM@KRMCONSULTANTS.COM
MECHANICAL & PLUMBING ENGINEER: AEC ENGINEERING
TAYLOR CRITCHLOW
PO BOX 8489
AVON, COLORADO 81620
P: 970.748.8520
F: 970.748.8521
E: TAYLOR@AEC-VAIL.COM
ELECTRICAL CONSULTANT: AEC ENGINEERING
DEREK FELSCHOW
PO BOX 8489
AVON, COLORADO 81620
P: 970.748.8520
F: 970.748.8521
E: DEREK@AEC-VAIL.COM
FIRE PROTECTION: COMPANY
CONTACT PERSON
ADDRESS
ADDRESS
P:
F:
E:
OWNER'S REP: NAME
ADDRESS
ADDRESS
P:
F:
E:
ARCHITECT: PIERCE ARCHITECTS
BILL PIERCE, PRINCIPAL IN CHARGE
1650 FALLRIDGE, C1
VAIL, COLORADO 81657
P: 970.476.6342
F: 970.476.4901
E: BILL@VAILARCHITECTS.COM
PLANNER: COMPANY
CONTACT PERSON
ADDRESS
ADDRESS
P:
F:
E:
CONTRACTOR: TBD
P:
F:
E:
DRAWING INDEX
NORTHWOODS UNIT B-102
N
SCALE: 1"=100'-0"
JAVIER MIGUEL NADER
ADDRESS
ADDRESS
P:
E: JMIGUELA3333@GMAIL.COM
F:
DRB
APPROVED
1/5/2016 12:00:00
AM