HomeMy WebLinkAboutDRB16-0078_C1_1478904170.pdf IVA OF gr,
it? ill 1111 :it
ec *n
IS ir
ild 1,5
+0 Lt4
1:10
DR:
APP-CVED
3/31 2016
12:0 i:Ob AM
3
Beth Levine
Architect,Inc.
Beth Levine Architect,Inc. September 19,2013 U
P.O.Box 1825 February 28, 2016 -
C
L. EAMAN RES I prNcE
Avon,CO 81620
(970)926-4993(P)
(970)926-2993(F) U
E-mail:beth�a bethlevinearchitect.com N N O p. p.
S -0 co cn
Leaman Residence Qo O ,o Z
1998 Sunburst Drive
0 m U � �
Vail,Colorado 81657 C o c 0 0
Zoning Analysislama SUNEURST A 4 5 C CD Q
,, ,
Two-Family Primary/Secondary Residential(PS)District s
,_N
Area: m
From:Improvement Location Certificate;Lealand Lechner,Land Surveyor;03-18-13. & Ili, 51
Parcel Area(acres)
A .148 CO
B .111
C-1 .068
VAIL. ,
C-2 .040
C-3 .014 VA I L VALLEY 3RD FILING, LOT II
Total .381 acres
.381 acres x 43,560 sq.ft./acre=16,596 sq.ft.
Allowed GRFA:
Area Percentage Calculated GRFA
Area Allowed
Sq.ft. Sq.ft. Sq.ft.
1-10,000 x.46 10,000 4,600
10,000-15,000 x.38 5,000 1,900 -
15,000-30,000 x.13 1,596 207
Total 16,596 6,707
40% 2,563 sq.ft.
60% 3,844 sq.ft.
Area Calculation Summary
Area Side"A" Side"B" TOTAL Q I m
Sci.ft. Sq.ft. Sq.ft. �/ ARCHITECTI RO V E C TDeJ
Basement 1,100 807 1,907 V I C I N I T I MA
Main Floor 1,832 1,310 3,142 NARRATIVE Upper Floor 1,250 1,017 2,267 iV/�I IONAL FORESTBETH LEVINE ARCHITECT, INC. (f)
4,182 3,134 7,316 I. EXPAND #IggS, "B" SIDE, NORTH PATIO. W
Over 16'height 521 72 593 P.O. BOX 1825 2. REMOVE THREE OLD BLUE SPRUCE TREES AND 0
(plus) AVON, CO 81620 REPLACE WITH THREE NEW, HEALTHY BLUE SPRUCE / Cr) 0
TOWN OF VAIL BOUNDARY (q-IO) g26-4gg3 FAX (q70) q26-2gg3 TREES.
Basement GRFA reduction: CONTACT: BETH LEVINE < W La b
Basement perimeter surface area exposed: > z
Total basement perimeter surface area: 2,810 sq.ft. TRACT CCL CO
Surface area buried: 1,026 sq.ft.
Surface area exposed: 1,784 sq.ft. �--- - fl O LL
%exposed: 63%
I-
U
0
""Basement GRFA: Q:arsTotal basement area= 1,907 sq.ft.
Times-percentage exposed x 63% 1ASTATO . GR VALUES ACT,Er, INXr,RA I G
GRFA= 1201 GRFA w
°""A'TE° NONE ADDED ILJJI rn _
Garage Reduction: �� G COVER
J
600 sq.ft.per side for garage= 1,200 sq.ft. D -I V Q
Basement GRFA= 1,201sq.ft.-1,200= 1 sq.ft. GRFA \ /
ERAGE TS SURVEY (f�
GRFA Summary: Side"A" Side"B" TOTAL SITE COY Q
Basement 1 0 1 ® Al SITE / MAIN LEVEL PLAN
HACK 10 I99S A VAIL VALLEY
"" 4th.FILING VALU!S Main Floor 1,832 1,310 3,142
7
Bis .. A
Upper Floor 1,250 1,017 2,267 / ® ai`.
aF ® 40 A2 WEST ELEVATION
Over 16' 521 72 593 1�_`, ® "'%E ' ' 4'i.; 7 NO SITE COVERAGE AREA ADDED
TOTAL 3,604 2,399 6,003 1L WiEE% Ins 1T
AVNNIXAES �'
ITSS ISI TRA47 A
1 % VAIL VALLEY 3rd.FILINGA RESUBDIVISION LIGHT
u8LATTE° PART OF SUNBURSTF A CUT O O R
Available GRFA:
Allowable: 6,707 sq.ft.
Existing GRFA: 6,003 sq.ft. -INC VALUES
Available: 704 sq.ft.GRFA
GRFA used in 2014 on side "A" =438 sq.ft. NO LIGHTS ADDED
GENERAL_ NCTS
Site Coverage: ZONING
g I. MATCH ALL EX I STING MATERI ALS AND
ZONE D I STRI GT: TWO FAMILY RESIDENTIAL STANDARD OF CONSTRUCT I ON UNLESS
Allowable Site Coverage: li NOTED OTHERWISE.
16,596 sq.ft.x .20 3,319 sq.ft. FRONT SET-BACK = 20 O 2. ALL DIMENSIONS ARE FRAMING UNLESS
UTILITY LOCATES SIDE AND BACK SET-BACKS = IS -O NOTED. VERIFY ALL DIMENSIONS WITH
Existing Site Coverage: O O THE ARCH I TECT.
Main Floor GRFA: 3,142 sq.ft. 3. DO NOT SCALE DRAW I NGS.
Entry roof covered area that is over 4'0"deep: 127 sq.ft THE 201S-02-2S, PROGRESS DRB SET, CONTAINED THE 4. THE DRAWI NGS, AND OTHER DOCUMENTS ISSUE DATE
Total Site Coverage: 3,269 sq.ft. FOLLOWING THREE REQUESTED CHANGES BELOW. THE INTERNATIONAL RESIDENTIAL CODE PREPARED BY BETH LEVINE ARCHITECT, PROGRESS 2016-02-21
UTILITY APPROVAL WAS REQUESTED ON THIS SET. 2015 INC. FOR THIS PROJECT ARE PROGRESS DRS 2016-02-28
Remaining Site Coverage: 50 sq.ft. BECAUSE THE F I NAL TOV DRB SET GONTA I NS ONLY THE INSTRUMENTS OF THE ARCHITECT'S
TOV DRB 2016-03-15
SIDE PATIO, A NEW UTILITY VERIFICATION WAS NOT SERVICE FOR USE SOLELY WITH
Landscape Area Required: REQUESTED. RE E RE NG E RESPECT TO THIS PROJECT AND UNLESS
60%of lot OTHERWISE PROV I DED I N WRITING, THE
Allowed Hardscape: I. EXTEND #I qqS, "B" FRONT DECK. r,SA I NS
G ARCHITECT SHALL BE DEEMED THE
40%of lot SOLE AND EXCLUSIVE AUTHOR OF THESE
(40)x 16,596= 6,638sgft. 2. EXPAND #IggS, "B" SIDE PATIO
DOCUMENTS AND SHALL RETAIN,
Existing Hardscape: EXISTING BUILDING DRAWINGS USED AS WITHOUT LIMITATION, ALL COMMON LAW,
Site Coverage =3,269 sq ft.
3. #I(IGO "B" AND #Igg4 "A" TOGETHER WOULD LIKE TO BACKGROUNDS WITH PERMISSION STATUTORY AND OTHER REVERSED
Driveway&Steps =1,440 sq.ft. ADD FIVE WOODEN DECORATIVE SITE PANELS TO FROM THE OWNER RIGHTS, INCLUDING THE COPYRIGHT
"B"Patio = 295 sgft. GRATE ADDED PRIVACY FOR BOTH UNITS. - HEREOF.
"A"Patio = 579 sq.ft.
TOTAL =5,583 sq.ft
New Hardscape added to "B"Patio = 140 sq.ft. -