Loading...
HomeMy WebLinkAboutDRB16-0085_A4.1_1478898361.pdf EXISTING STUCCO EXISTING GALVANIZED METAL CAP # 4. PLYWOOD 1/4" CLEAR BETWEEN STUCCO $ "TREX FLASHING OVER BITUTHENE i TRANGEND DECKING (TO BE GUT TO SIZE AT AT ALL BEAMS, RIM JOISTS, 114roj .051.60 EDGES WHERE DECKING ADJOINS BUILDING DECK JOISTS EXPOSED TO WEATHER, TYP. AMC 1 NEW TREX ► BITUTHENE APPROVED TRANCEGEND 4/19/2116 I DECKING EXISTING SLIDING z \ 12:00:'0 AM I c - - NEW 3 g" xl " R.S. GDOORS DOOR OR ENTRY NEW BEAM OROEXISTING REMAIN - DECK I / CEDAR GLULAM TOP - - - I- CONT. NEW PAINTED GALVANIZED FLASHING ON ALL RIM RAIL (GUARDRAIL) VI CTOR VAR K EXISTING RIM JOIST I ► JOISTS,EXISTING DECK JOISTS THAT ARE EXPOSED TO I MOISTURE. (STAIRS,AND COVERED BREEZEWAY JOISTS ^� EXISTING D 0 N A L D S O N OR BLOCKING I ARE NOT EXPOSED) FINISH FLOOR NEW GALVANIZED THRESHOLD I . • FLASHING, TYPICAL I CONTRACTOR SHALL PATCH 8 REPAIR z_ NEW Ix CONT. CEDAR TRIM DAMAGED 8 DEMOLISHED STUCCO (DUE = N XO j EXISTING FLOOR"/ TO MATCH EXISTING TO ADDITION OF NEW FRAMING) COLOR uxi W w ASSEMBLY 6' AND TEXTURE SHALL MATCH EXISTING mo m p Q w -> w3/4" I/ " GAP ETA I 5 SCALE: 1 ii = I' - O" 2 NEW 2x6 "TREX TRANGEND DECKING COLOR TREE HOUSE" 2x6 BALUSTERS,CUT TO \ I j/j/ j� 4•"�/ INSTALL PER MANUFACTURERS SPECS AND 20001 TREX SHAPE TO MATCH EXISTING. - I - A4.1 INSTALLATION GUIDE. f I ARCHITECTURE 3 EXISTING FLOOR 1 PLANNING IA4.1 FRAMING / CONT. NEW PAINTED 4X8 PRESSURE TREATED TIMBER INTERIORS EXISTING RIM JOIST I z I T30 STAR DRIVE BRONZE i GALVANIZED FLASHING SAILOR COURSE BORDER SINCE 1977 OR BLOCKING NEW 4x8 FRAMING,SEE FASTENERS (TOP AND STRUCTURAL PLANS I ► EXISTING L PLAZA SERIES PAVERS (2:3 PROPORTION) BOTTOM,TMP.) i BLOCKING ARCHITECT S CONT. NEW PAINTED GALVANIZED FLASHING ON ALL RIM NEW bx14 WOOD BEAM,SEE NEW DECK FRAMING, SEE 90 W B E N C H V A R K R 0 R D JOISTS,EXISTING DECK JOISTS THAT ARE EXPOSED TO STRUCTURAL PLANS I STRUCTURAL MOTS URE. (STAIRS,AND COVERED BREEZEWAY JOISTS r SUITE 2 0 l ARE NOT EXPOSED) -------------.CONTRACTOR SHALL PATCH DEMOLISHED EXISTING r EX. WALL FRAMING BOX O X �j v 3 0 O AVON CO 81620 STUCCO (DUE TO NEW FRAMING) COLOR AND TEXTURE SHALL MATCH EXISTING EXISTING PLYWOOD 7 EXISTING STUCCO STRUCTURALOPLANS POST,SEE SHEATHING 90 . 949 . 5200 I EXISTING STUCCO _IN_ _IN_ N / 7 chrisj@vmda. com FAX 949 . 5205 -TA} -TA — — - - �� �. CSCALE: I" = I' - O" SCALE: I" = I' - 0" ‘; C O/ �'N,, �� t1,r, \,‘\ NEW POLYMER MODIFIED CEMENT WATERPROOFING DECK SURFACE ` - SYSTEM CONSISTING OF METAL LATH, _ 5 Co, V fOR 0 2" CLEAN 4 COMPACTED AS1 POLYMER MODIFIED CONCRETE, - A4.1 = I ;ARK 5/8" WIRSB0 SNOW-MELT SYSTEM ON BEDDING 4 JOINT SAND BARRIER GUARD RESISTITE, AND TWO #10x#10 - 6"x6" E.KIALM. D 4 X 8 P.T. TIMBER COATS OF POLYESTER URETHANE .` 'i FiN ::: ::::: GRATE 11/2" RIGID EXISTING LANDSCAPING SEALANT ALL SUPPLIED BY INSULATION CONTRACTOR (SLIP COEFFICIENT TO /Y, �'S. � / / / � o I IIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII BE 0.8 WET OR DRY) SLOPE 1/8" PER SLOPE_ n i/Aj/ ///j � j A,/���A FOOT AWAY FROM BUILDING RE: 1)---,--,i---,-=-- - 7/8" DEEP MO A MANUAL j \ C ALUM. GUTTER CONTRACTOR TO _ wIIIIPIIII 11111 III 11111 III 11111 ud IJ l \/\\/ � jjTAPERED FOAM INSULATION // FIELD VERIFY LENGTH PRIOR `'`M-\ N— \ NEW 5/8 EXTERIOR GRADE TO ORDERING GUTTER / PLYWOODCONT. NEW PAINTED / /� TREX TRANSCENDS "TREE HOUSE" GALVANIZED FLASHING Z \ \ \ \\ /\\ /\\ \ \\ DECKING (TO BE CUT TO SIZE AT Ily1 — Oa \ \/MASONRY PAVERS, 2 3/4 THI . \ EDGES WHERE DECKING ADJOINS • C / / /PAVESTONE " PLAZA SERIES" 'r /.PAVESTONE "HOLLAND SERIES\ / BUILDING 2 Y4" DIA. THROUGH BOLTS w /�\ /�\ /�\ /PERIMETER ROW. \ /�\ /�\ /� CONT. NEW PAINTED GALVANIZED FLASHING ON ALL FRAMING (MATCH EXISTING) PART A5R AVER A Z m TIMBERS (NEW 4 EXISTING) SCALE: I" - I' - 0" O ~ E T�' CA, PAVER D-TA _ U - J Q o 5 SCALE: I" = I' - O" Q U) 111 CO 1 " NEW 6x14 HOOD BEAM, SEE CO f2 Umil 4'-O" STRUCTURAL PLANS LL .7( J N- / / O F = 0 co 2" CLEAN 4 COMPACTED "� z � � w0 5/8 WIR5B0 SNOW-MELT SYSTEM ON BEDDING 4 JOINT SAND NEW 6x6 WOOD POST, SEE I-LI ° CNN) D#IOx#10 - 6"x6" E.W.W.M. NEW POLYMER MODIFIED CEMENT STRUCTURAL PLANS EXISTING SLIDING WATERPROOFING DECK SURFACE = m 0 Q 11/ 2" RIGID EXISTING LANDSCAPING V GLASS DOOR OR SYSTEM CONSISTING OF METAL LATH, , ENTRY DOOR AbI POLYMER MODIFIED CONCRETE, 0 < ,/\/„ �j �j AU j�����/ ����j ��� - — BARRIER OF POLYESTER URETHANEND TWO \/ / \ CONTRACTOR TO VERIFY T CiA < GU T TJLOCATION, TYPE ANDSEALANT ALL SUPPLIED BY < _ @Illllllllii'"'I' '1'191"I "'I "'I °I "I "'I "'11��91'I �I "" ELEVATIONS OF EDGE CONTRACTOR (SLIP COEFFICIENT TO =ma Q /\ RESTRAINTS AROUND THE I. SCALE: 3 = I - O BE O.& WET OR DRY) SLOPE 1/8" PER LLcii > \ PERIMITER AREA TO BE \ I. 1 FOOT AWAY FROM BUILDING in >- \ PAVED. THE BASE SHALL \ -.11 EXISTING STUCCO �z �— TAPERED FOAM INSULATION Q aCri \/ I / / / I /\ EXTEND 6 MIN. BEYOND THE \ NEW "J" WEEP SCREED (STUCCO NEW CONT. GAL. / / .7-0147Y -A rt 3 K. / \ AREA TO BE PAVED WHEN BOTTOM EDGE) FLASHING I - NEW 5/8 EXTERIOR GRADE PLYWOOD \ \\ \\ \\ \\ \/PF,,IR A`4 5 • . R \ \ USING "PAVECURBING OR I \ . . . .\ \ \\ J A/\ \ \ \ \ P A 5 E\ NEW POLYMER MODIFIED CEMENT I TREX TRANSCEND TREE HOUSE �A/�A/�A/�A/�A , E -RA• ./ A / A/A///,, SUITABLE WATERPROOFING DECK SURFACE I DECKING (TO BE CUT TO SIZE AT Q ESTABLISHED/EXISTING SYSTEM CONSISTING OF METAL LATH, EDGESDING WHERE DECKING ADJOINS • STRUCTURE A81 POLYMER MODIFIED CONCRETE, I BUIL E — BARRIER GUARD, RE515TITE, AND ICONT. NEW PAINTED GALVANIZED A A, A' 3 TA „ TWO GOATS OF POLYESTER URETHANE SEALANT ALL SUPPLIED EXISTING OR NEW 1/2" PLYWOOD I I- FLASHING J) D� TM _ _ - �' \ BY CONTRACTOR (SLIP COEFFICIENT ►- EXISTING OR NEW LEDGER, Gl- SCALE: - O TO BE O.8 WET OR DRY) SLOPE I/8" I RE: STRUCTURAL PLANS PER FOOT AWAY FROM BUILDING I I ©COPYRIGHT NEW CONT. GAL. I �— TAPERED FOAM INSULATION Victor Mark I Donaldson FLASHING I - NEW 5/8" EXTERIOR GRADE PLYWOOD I Architects I ,\ \ 1 I EXISTING STUCCO All serrved I \ TREX TRANSCEND "TREE HOUSE I I DECKING (TO BE CUT TO SIZE AT _ 1 I ;, EDGES WHERE DECKING ADJOINSBUILNG R E S I 0 I CONT.T.1 NEW PAINTED GALVANIZED _ EXISTING OR NEW i FLASHING/ I REI:SSTRU URAL PLANSER, I DATE 03/28/2016 JOB \O. 1524 ► EXISTING STUCCO c'l E7ETA = DETAILS ►' SCALE: 3" = I' - O" E.;� 1:),----TASHEET N0. A4 . 1 •� SCALE: 3" = I' - 0"