Loading...
HomeMy WebLinkAboutDRB16-0098_Long 3_1478908930.pdf GENERAL NOTES: ALL DIMENSIONS/ HEIGHTS TO BE FIELD VERIFIED AND '" BASED ON EXISTING STRUCTURE. MATCH EXISTING '4, THERCHES PROJECT. PLANS ARE DERIVED FROM THE ORIGINAL OVA(107 HOUSE AND MAY HAVE VARIATIONS TO BUILT ARCHITECTURAL DETAILING THROUGHOUT iiDRB STRUCTURE. VERIFY PRIOR TO CONSTRUCTION. 4/13/2016ED 12:00:00 AM ALL INTERIOR WALLS ARE 2X4, EXTERIOR ARE 2X6, HEM-FIR STUD FRAMING AT 16"O.C. UNLESS OTHERWISE design NOTED. RE: STRUCTURAL construction ALL WALLS AND CEILINGS ARE TO BE COVERED WITH 1/2" sustainable design DRYWALL. PROVIDE TYPE X DRYWALL UNDER ALL STAIRS outdoor living AND NECESSARY FIRE SEPARATION AREA PER LOCAL g CODE. PROVIDE WATER RESISTANT DRYWALL TO ALL WET NEW WINDOW TO residential AREAS. 1 MATCH EXISTING LEE)AP certified ALL CONSTRUCTION IS TO CONFORM TO REQUIRED LOCAL BUILDING CODES AND 2015 IRC. =========== ======== -Cgiiiif•• • ' EXISTING VERTICAL REFER TO MANUFACTURE RECOMMENDATIONS FOR ALL SIDING TO REMAIN New and relocated windows Parallel Design Group I BUILDING PRODUCTS. c RELOCATE AND "define your own lines" REFER TO STRUCTURAL PLANS FOR ALL STRUCTURAL CENTER NEW 303.607.0544 REFERENCES INCLUDING, BUT NOT LIMITED TO, HEADERS, 1 ' 1 1 1 1 1 1 _ 11111 WINDOW IN STAIR TRIM STUDS, FLOORING, CONNECTIONS AND BEAMS. WELL www.paralleldesigngroup.com ELECTRICAL LAYOUT IS SCHEMATIC AND MUST BE EXISTING STANDING COMPLETED PER LOCAL CODES. PROVIDE SMOKE AND SEAM METAL ROOF CARBON MONOXIDE DETECTORS PER LOCAL CODES. TO REMAIN TYPICAL HEADER HEIGHT IS 7'-0"UNLESS THERE ISA , 90.23'T.O.SECOND FLOOR SUBFLOOR TRANSOM OR OTHERWISE NOTED. b ,�89.4' B.O. MAIN FLOOR CEILING CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE PLANS REPLACE ALL PRIOR TO STARTING ANY AND ALL CONSTRUCTION. ANY piip EXISTING WINDOWS DETAILS NOT INCLUDED OR SPECIFIED ON PLANS MUST BE WITH NEW ENERGY BROUGHT TO THE ATTENTION OF THE OWNER,AND EFFICIENT WINDOWS I APPROVED BY OWNER, PRIOR TO STARTING IN SAME LOCATION CONSTRUCTION. CONTRACTOR WILL BE RESPONSIBLE FORAND SIZE ANY ASSUMPTIONS MADE TO PLANS WITHOUT OWNER sc'11) 111111 APPROVAL. ao N EXISTING HEAT TO BE MODIFIED THROUGHOUT PROJECT EXISTING TRIM TO Tmil BASED OFF NEW PLANS. S: : lz atrg. zawi.- - .� -R" M i-aaa: 1! �sr: �.� a,_ me: _,�. �:-1- � .�� � .fir ` REMAIN ��r��Ta��'ir��i��'�`�"trir�TirTa�Tar�Tir-.�Tir�T•-'r�'�r�'���'Tiir�'�r�Tr�"fri�'L`ir�Tr��Tir�'��"trir >: _sAR 1 ��" _ _� _ _PA_IAIR _ _� MI ER M �!_:aR_ s s as; EXISTING DECK TO VERIFY ALL WALLS AND FLOORS TO BE DEMOLISHED � ��" TSS ?�! �" �`�" ��S ' ��"��s _ I ,�81.4'J0R.O. MAIN FLOOR 0T.O. BASEMENT CEILING EP _�! !_,! l �1._� _sr R_me!_� Na� �1,1=10� 1. rA'i'Z'�C C ar.�Tr+r it 1P WO .1 r !: 11..a'rirr.�Trar.�'�ii .�'r+r. � +r•I TO REMAIN i�Xk�K� - UNDER/OVER FRAMING 1'��° � -sl�s��s ��r-�s��� � ��, .!�, : - �s��s �s���R �s �s� �s:7� _ ����_ � CO - DEMOLISH in in ENGINEERS ON PROJECT: 0 U0 DOSSEY/SUDIK STRUCTURAL ENGINEERS ' PLAZA QUEBEC ° 75.11'T.O. EXISTING FOOTING+/- 6025 SOUTH QUEBEC STREET SUITE 375 CENTENNIAL, COLORADO 80111 ENGINEER OF RECORD: DAVID W. DOSSEY,37653 romt STARBUCK SURVEYORS ,�71.57'T.O. NEW SLAB ir0.m. ..1P.O. BOX 1584 Li__1 0031 EAGLE PARK EAST DRIVE c 1 EAGLE, CO 81631 v la<„,,.....„._ ENGINEER OF RECORD: RICHARD E. BORDEN,30084 LELAND LECHNER Z so"....11116 30946 COUNTY ROAD 356 BEUNA VISTA,CO 81211 / L.1.11 ENGINEER OF RECORD: LELAND LECHNER,23506 1 01 PROPOSED FRONT ELEVATION Ia. 1` LKP ENGINEERING, INC. Q Ia. ! P.O. BOX 2837 EDWARDS, CO 81632 A2. SCALE: 1/4" = 1'-O" ENGINEER OF RECORD: LUIZA PETROVSKA,29526 ., SQUARE FOOTAGE: v Li__1 BASEMENT FINISHED: 1,302 SQFT ( �/ BASEMENT UNFINISHED: 296 SQFT EXISTING MAIN FLR/REMODELED: 1,364 SQFT PROVIDE NEW SNOW ...it NEW MAIN FLOOR ADDITION: 105 SQFT FENCE ON ALL REAR UPPER FLOOR REMODEL: 674 SQFT FACING ROOFS EXISTING GARAGE: 338 SQFT (3 U TOTAL FINISHED AREA: 3,445 SQFT EXISTING CHIMNEY TO REMAIN LI.1 4"11EXISTING ROOF TO1 11'��� _ REMAIN � EXISTING VERTICAL 111111 - - - SIDING TO REMAIN New roof created by elimination of deck off0 . i � �• iii _� NEW ROOF TO t ^ AK � MATCH EXISTING. master bed room ' � �����t VERIFY PITCH. fa" III aim iri-- 21:111 it NEW VERTICAL ��i/i:� n i t 12 %_ it. W►.. - -14 ��/,07_, SIDING TO MATCHI 111111 i 'i* EXISTING ,� ��� t ��� � I NEWS"GVl-f'ERAND I 1 �■ i�■� i -�� L��r'� FASCIA PAINTED TO MATCH EXISTING 90.23'T.O.SECOND FLOOR SUBFLOOR- AI==Air 89.4' B.O. MAIN FLOOR CEILING. o �'� � EXISTING DECK TO '' -' ' _ , ...... i( REMAIN. NEW �ti� l lar� FRONT DOOR �-?: L��. � NEW VERTICAL � I � �`- HA N D RA I L TO �> . � tm � MATCH EXISTING o ii 'gi ZIM STYLE co _t_ __14-14,r-_7 r_oi ow s. - ,�. � rr� � rr� Lt , N lij �j L. � . �l�r! r . � �� At ri �i sir 1 81.4'T.O. MAIN FLOOR SUBFLOOR +-� 1 'j_Livilli�' �' �' �iiials �i� � _� �l �rli J 80.57'T.O. BASEMENT CEILING O mi Ai�,�willnalMiliiniiMO�l� NEW WATER CATCH kiiii PAN FOR DRAINAGE Ln in,'� / 75.11'T.O. EXISTING FOOTING / m ISSUED FOR: DATE: SS A ii //� i. //iiiiid/////r i iris/�� ,. AAL 71.57 T.O. NEW SLAB I 03/09/2016 � CONSTRUCTION DOCUMENTS SHEET NUMBER: 2PROPOSED SIDE ELEVATION A2,0f SCALE: 1/4" = 1'-O" A2 . 0 lr