Loading...
HomeMy WebLinkAboutDRB16-0098_Long 4_1478908933.pdf _ Alpiv. GENERAL NOTES: Z7.4ti-V., ALL DIMENSIONS/ HEIGHTS TO BE FIELD VERIFIED AND BASED ON EXISTING STRUCTURE. MATCH EXISTING Ilk 1 ARCHES AND ARCHITECTURAL DETAILING THROUGHOUTii �00 THE PROJECT. PLANS ARE DERIVED FROM THE ORIGINAL HOUSE AND MAY HAVE VARIATIONS TO BUILT DRB APPROVED STRUCTURE. VERIFY PRIOR TO CONSTRUCTION. I 4/13/2016 12:00:00 AM ALL INTERIOR WALLS ARE 2X4, EXTERIOR ARE 2X6, HEM-FIR STUD FRAMING AT16"O.C. UNLESS OTHERWISE design NOTED. RE: STRUCTURAL construction ALL WALLS AND CEILINGS ARE TO BE COVERED WITH 1/2" sustainable design DRYWALL. PROVIDE TYPE X DRYWALL UNDER ALL STAIRS outdoor living AND NECESSARY FIRESEPARATION AREA PER LOCAL New windows and roof from CODE. PROVIDE WATER RESISTANT T DRYWALL TO ALL WET EXISTING STANDING SEAM residential AREAS. METAL ROOF TO REMAIN `rr--r-r- LEEP AP certified ALL CONSTRUCTION IS TO CONFORM TO REQUIRED LOCAL elimination of deck BUILDING CODES AND 2015 IRC. REFER TO MANUFACTURE RECOMMENDATIONS FOR ALL PROVIDE NEW SNOW FENCES �I!`�~ — I Parallel Design Group BUILDING PRODUCTS. ON ALL REAR FACING ROOFS • -h "dune your own lines" REFER TO STRUCTURAL PLANS FOR ALL STRUCTURAL _m 303.607.0544 REFERENCES INCLUDING, BUT NOT LIMITED TO, HEADERS, L TRIM STUDS, FLOORING, CONNECTIONS AND BEAMS. NEW ROOF. MATCH EXISTING. - www.para((eldesigngroup.com ELECTRICAL LAYOUT IS SCHEMATIC AND MUST BE NEW 5"GUTTERS AND FASCIA — COMPLETED PER LOCAL CODES. PROVIDE SMOKE AND PAINTED TO MATCH EXISTING CARBON MONOXIDE DETECTORS PER LOCAL CODES. / TYPICAL HEADER HEIGHT IS 7'-0"UNLESS THERE IS A TRANSOM OR OTHERWISE NOTED. EXISTING VERTICAL SIDING TO 90.23'T.O. SECOND FLOOR SUBFLOOR REMAIN CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE PLANS 89.4' B.O. MAIN FLOOR CEILING NEW WOOD ENERGY EFFICIENT PRIOR TO STARTING ANY AND ALL CONSTRUCTION. ANY '. WINDOWS THROUGHOUT Ps. DETAILS NOT INCLUDED OR SPECIFIED ON PLANS MUST BE I III II II I II I I I II I IIIII BROUGHT TO THE ATTENTION OF THE OWNER,AND NEW VERTICAL HANDRAIL. 36" APPROVED BY OWNER, PRIOR TO STARTING MIN HEIGHTAND 3i"MAX CONSTRUCTION. CONTRACTOR WILL BE RESPONSIBLE FOR SPINDLE SPACING. INSTALL PER IA. N ANY ASSUMPTIONS MADE TO PLANS WITHOUT OWNER LOCAL CODES AND APPROVAL. o MANUFACTURES EXISTING HEAT TO BE MODIFIED THROUGHOUT PROJECT Op RECOMMENDATIONS A� ‘n-1 BASED OFF NEW PLANS. VERIFY ALL WALLS AND FLOORS TO BE DEMOLISHED 0 ill - NEW WALLS , 81.4'T.O. MAIN FLOOR SUBFLOOR \j ,�80.57'T.O. BASEMENT CEILING ��� UNDER/OVER FRAMING , CO - DEMOLISH NEW VERTICAL SIDING TO MATCH EXISTINGDesi n changefrom0ENGINEERS ON PROJECT: Nin g DOSSEYNEW WOOD ENERGY two windows to three PLAZA /SUDIK STRUCTURAL ENGINEERS EFFICIENT WINDOWS AND 5" �� U PLAZA QUEBEC TRIM TO MATCH EXISTING 6025 SOUTH QUEBEC STREET , 75.11'T.O. EXISTING FOOTING+/- SUITE 375 CENTENNIAL, COLORADO 80111 ENGINEER OF RECORD: DAVID W. DOSSEY,37653 ■■■■■■■■■■■■■■■■■■■■■■ ■■■■■■■■■■■■■■■■■■■■■■■■ .1 STARBUCK SURVEYORS Li_.1 1 - P.O. BOX 1584 , 71.57'T.O. NEW SLAB r ' 0031 EAGLE PARK EAST DRIVE II<i..........._ EAGLE, CO 81631 vim ENGINEER OF RECORD: RICHARD E. BORDEN,30084 LELAND LECHNER Z sio...°311 30946 COUNTY ROAD 356 BEUNA VISTA, CO 81211 ill ENGINEER OF RECORD: LELAND LECHNER,23506 1 \ PROPOSED REAR ELEVATION L r 1` LKP ENGINEERING, INC. Q _.._.1 P.O. BOX 2837 EDWARDS, CO 81632 A2,VSCALE: 1/4" = 1'-0" ENGINEER OF RECORD: LUIZA PETROVSKA,29526 ` ...... SQUARE FOOTAGE: U Li_.1 BASEMENT FINISHED: 1,302 SOFT BASEMENT UNFINISHED: 296 SQFT EXISTING MAIN FLR/REMODELED: 1,364 SOFT gm.", NEW MAIN FLOOR ADDITION: 105 SQFT UPPER FLOOR REMODEL: 674 SOFTU EXISTING GARAGE: 338 SQFT L..3 TOTAL FINISHED AREA: 3,445 SQFT z Li_Ja 0 inmse 40=NJ V. Li r.L.../ 1,.... v•> N in % ... ISSUED FOR: DATE: CONSTRUCTION DOCUMENTS 03/09/2016 SHEET NUMBER: A2 . 02