Loading...
HomeMy WebLinkAboutDRB160032_A2.2_1456263300.pdfA D E F J K M N O Q R S T U X Y AA Z P G B C H I W V L REIMERS LOWER LEVEL AREA 2247.25 SF 27' - 0" 25' - 6" 3' - 0" 5' - 2" 16' - 0" 9' - 5" 8' - 0" 2' - 4" 3' - 6" 12' - 3" 2' - 2" 5' - 10 1/2" 4' - 5 1/2" BB 1' - 0" 14' - 11 1/2" 2' - 4" 17' - 0 1/2" 3' - 6" 13' - 0" 9' - 10 1/8" 18' - 10 3/16" 14' - 3" 1' - 10" 4' - 3" 6' - 0" 10' - 0" 1' - 10" 4' - 9 9/16" Basements: On the lowest level of a structure, the total percentage of exterior wall surfaces unexposed and below existing or finished grade, whichever is more restrictive, shall be the percentage of the horizontal area of the lowest level deducted from the GRFA calculations. The percentage deduction calculations shall be rounded to nearest whole percent. The lowest level's exterior wall surface area shall be measured from the finished floor elevation of that level to the underside of the structural floor members of the floor/ceiling assembly above. For the purposes of these calculations, retaining walls and site walls shall not be considered part of the lowest level's exterior walls. REIMERS LOWER LEVEL GRFA 2247.25 X 0.52 = 1,168.4 SF 27' - 0" 5' - 2" 16' - 0" 9' - 5" 8' - 0" 3' - 6" 2' - 4" 12' - 3" 5' - 10 1/2" 2' - 2" 4' - 5 1/2" 1' - 0" 14' - 11 1/2" 2' - 4" 17' - 0 1/2" 3' - 6" 13' - 0" 4' - 9 9/16" 9' - 10 1/8" 18' - 10 3/16" 14' - 3" 4' - 3" 1' - 10" 6' - 0" 1' - 10" 10' - 0" 25' - 6" 3' - 0" A C E F G I B.O. STRUCTURE @ 10' -7 5/8" L N LOWER LEVEL F.F. @ 1' - 6 1/4" B.O. STRUCTURE @ 11' -11 1/4" B D H O J K M P Q R S T U X Y AA Z W V BB 9' - 1 3/8" LOWER LEVEL F.F. @ 1' - 6 1/4" TOTAL WALL AREA= 2,261.8 SF COVERED WALL AREA = 1,091.5 SF 1091.5 SF / 2,261.8 SF = ..48 X 100= 48% OF THE LOWER LEVEL EXTERIOR WALL IS COVERED. THEREFORE 52% OF THE LOWER LEVEL AREA COUNTS TOWARDS GRFA. REIMERS MAIN LEVEL AREA 2258.5 SF REIMERS GARAGE AREA 560 SF 27' - 0" 16' - 0" 8' - 0" 25' - 6" 3' - 0" 5' - 2" 9' - 5" 2' - 4" 3' - 6" 12' - 3" 2' - 2" 5' - 10 1/2" 4' - 5 1/2" 1' - 0" 14' - 11 1/2" 2' - 4" 17' - 0 1/2" 3' - 6" 13' - 0" 1' - 10" 10' - 0" 6' - 0" 4' - 3" 9' - 3" 2' - 3" 1' - 10" 5' - 0" 9' - 10 1/8" 16' - 7 3/16" 4' - 9 9/16" REIMERS MAIN LEVEL GRFA 2258.5 SF 23' - 6" 22' - 10 1/16" 1' - 2" 3' - 7 1/2"19' - 10 1/2" REIMERS UPPER LEVEL AREA 2139.5 SF REIMERS DOUBLE-HEIGHT SPACE AREA 649 SF 16' - 0" 8' - 0" 2' - 4" 9' - 5" 3' - 6" 12' - 3" 2' - 2" 1' - 0" 5' - 10 1/2" 4' - 5 1/2" 14' - 11 1/2" 10' - 0" 11' - 2" 13' - 0" 14' - 0 1/2" 27' - 0" 22' - 2 1/2" 25' - 6" 1' - 10" 10' - 0" 6' - 0" 4' - 3" 1' - 10" 1' - 10" 14' - 3" 18' - 10 3/16" 10' - 4"13' - 2" 1' - 2" 21' - 10" 1' - 0" 10' - 4"13' - 2" 4' - 9 9/16" 7' - 8" 17' - 0 1/2" 19' - 2 1/2" REIMERS UPPER LEVEL GRFA 2788.5 SF DATUM: 0' - 0" = 8300' - 0" PROPOSED SQUARE FOOTAGE ANALYSIS: 3090 Booth Creek Drive, VAIL, CO Zone District: Two-Family Primary/Secondary Residential ( PS ) Lot is .3.28 acres, equal to 14,288 SF Allowable GRFA .46 SF/1 SF of site area < 10,000 SF of site area 10,000 x 0.46 equals 4,600 SF .38 SF per 1 SF of site area > 10,000 SF of site area 5,000 x 0.38 equals 1,629 SF .13 SF per 1 SF of site area > 10,000 SF of site area 6,026 x 0.13 equals 0 SF _______________________________________________________________________ ________ Total Allowed Gross Residential Floor Area (GRFA) for entire lot 6,229 SF Proposed Square Footage Summary (Both Sides of Duplex Combined) Habitable SF GRFA Lower Level 2,247.25 SF 1,168.4 SF *1 Main Level 2,266.5 SF 2,266.5 SF Upper Level 2,139.5 SF 2,139.5 SF Garage area over 600 SF 0 SF Double height space__________________649 SF___________ Total 6653.25 SF 6,223.4 SF Total Remaining GRFA 5.6 SF *1 48% of the Lower Level wall is above existing or finished grade whichever was more restrictive, therefore 52% of the Lower Level SF is counted as GRFA (LOWER LEVEL HABITABLE 2,247 SF * .52 = 1,168.4 SF) NOTE- THESE NUMBER ARE APPROXIMATE UNTIL SUBGRADE AREA CALCS ARE COMPLETED Site Coverage Allowable Site Coverage is 20% of the lot 2,858 SF Proposed Site Coverage 2,818.5 SF Proposed Site Coverage for Roofs beyod 4' 34.00 SF Total Proposed Site Coverage 2,844.5 SF Total Remaining Site Coverage both sides 5.5 SF Landscape Area Lot Size 14,288 SF 60% Landscape Area Requirement 8,572.8 SF Lot Size 14,288 SF LESS Building Footprint / Driveway -5,092.5 SF Total Landscape Area 9,195.5 SF Total Hardscape Area Provided (8.3%) 1,666 SF Total Softscape Area Provided 7,529 SF Proposed driveway with snowmelt 2,282 SF Proposed snowmelt @ south patio/ Firepit 253.5 SF Proposed snowmelt zone to lower level 299 SF Setbacks 20' from front 15' from sides 15' from rear Patio can extend to 1/2 the distance of the setback Decks can encroach set back 5' Roof or architectural projections can encroach 4' Height Flat or mansard roofs not to exceed 30' Sloping roof not to exceed 33' Garage Allow 600 sq. ft. per unit. before area counts towards GRFA 560 SF is provided. Parking Required per Chapter 10 Primary dwelling unit is more than 5,500 SF GRFA 5 spaces are required. 2 covered 9' x 18' (in garage) and 3 uncovered 9' x 19' parking spaces are provided. REIMERS MAIN LEVEL AREA 2258.5 SF REIMERS GARAGE AREA 560 SF 16' - 0" 8' - 0" 25' - 6" 3' - 0" 5' - 2" 9' - 5" 2' - 4" 3' - 6" 12' - 3" 2' - 2" 5' - 10 1/2" 4' - 5 1/2" 1' - 0" 14' - 11 1/2" 2' - 4" 17' - 0 1/2" 3' - 6" 1' - 10" 10' - 0" 6' - 0" 4' - 3" 9' - 3" 2' - 3" 1' - 10" 5' - 0" 16' - 7 3/16" 19' - 10 1/2"3' - 7 1/2" 1' - 2" 22' - 10 1/16" 23' - 6" 4' - 9 9/16" 12' - 10 5/8" 1' - 3 5/16" REIMERS TOTAL SITE COVERAGE 2852.5 SF AREA OF ROOF BEYOND 4' 34 SF Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION As indicated 2/4/2016 1:49:08 PM 3090 BOOTH CREEK DR. VAIL, CO A2.2 AREA CALCS CWF HB REIMERS RESIDENCE 02/04/2016 TOV DRB CHANGE TO APPROVED PLANS 1/8" = 1'-0" 1 LOWER LEVEL AREA PLAN 1/8" = 1'-0" 2 MAIN LEVEL AREA PLAN 1/8" = 1'-0" 3 UPPER LEVEL AREA PLAN 1/8" = 1'-0" 4 SITE COVERAGE No. Revision Date Revision Description 1 FEBRUARY 4, 2016 CHANGES TO APPROVED DRB * BUILDING WAS ELEVATED 5 1/2" TO MITIGATE HIGH GROUND WATER TABLE. * ELECTRICAL CLOSET WAS MOVED FROM THE NORTH WALL OF GARAGE TO THE EAST WALL OF GARAGE. DRB APPROVED 2/23/2016 12:00:00 AM