Loading...
HomeMy WebLinkAboutDRB160032_A3.1_1456263300.pdfUP UP E08' E06' E04' E02' E14' E12' G E10' A4.3 A4.4 1 1 A4.1 1 T.O. CONC. 1' - 5 1/2" T.O. FINISH 1' - 6 1/4" 4' - 0" 10' - 3" 3' - 1" BEDROOM #5 015 AV EQUIP. RM. 012 STORAGE 009 LAUNDRY ROOM 006 POWDER 005 MECHANICAL ROOM 008 W.C. 010 BATH #5 011 HALLWAY 007 WET STORAGE 004 WINE RM. 003 STAIRS 002 WASHER DRYER EXERCISE AREA SHOWER BENCH 3' - 0" EXERCISE EQUIPMENT STORAGE 017 FD FULL BED W/ DRAWERS BELOW SHELVING W/ MECHANICAL DUCTS ABOVE 2" 4" FD 5' - 3" A4.5 2 A4.5 3 1 A5.5 1 A5.7 1 A5.6 2 A5.5 A4.5 1 FAMILY ROOM 001 1 A5.1 4 A5.5 1 A6.1 3 A6.1 1 A6.2 3 A6.2 2 A6.2 5 A6.2 7 A6.2 FD 2 A6.5 1 A6.3 2 A6.3 6 A6.2 3 A6.3 2 A6.3 2 A6.3 LINE OF WALL ABOVE 1 A5.2 1 A5.3 1 A5.4 2 A5.4 3 A5.5 1 A5.8 1 A5.9 008A 005A 009A 011A 012A 015A 001A 004A 004B 003A TILE WOOD EPOXY WOOD TILE CARPET CARPET WOOD WOOD WOOD EPOXY EPOXY 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 A A B B C C D D E E F F G G J J K K L L G1 G4 GD GD GC GC GA GA GB GB H H I I G5 G2 002 2' - 4" 3' - 6 1/2" 4' - 5 1/2" 14' - 11 1/2" 1' - 0 1/2" 15' - 11" 11' - 1" 2' - 0" 9' - 3" 14' - 3" 3' - 1" 81' - 11" 17' - 4 1/2" 5' - 5 1/2" 1' - 2" 5' - 5 1/2" 29' - 5 1/2" 1' - 9 1/2"8' - 6 1/2"13' - 2" 23' - 6" 1' - 3" 1' - 0" 1' - 4"10" 12' - 3" 3' - 6" 1' - 7" 6' - 0" 2' - 0 7/8" 4' - 11 1/8" 3' - 0" 37' - 9" Q Q A9.7 3 2 CONCRETE PATIO CONCRETE STAIRS 5 1/2" 7 1/2" 7 1/2" 5 1/2" 1 A6.4 1 A6.4 NO INSULATION UNDER SLAB IN WINE ROOM. NO RADIANT HEAT IN WINE ROOM SLAB. PROVIDE EXPANSION JOINTS IN SLAB. 3 A6.4 2 A6.4 G3 1 A6.1 1 A5.10 FD HB FLOOR DRAIN AC UNIT 1' - 0" 4' - 0" 3' - 6 1/8" T.O. DRAIN 0' - 10 3/8" @ DRAIN T.O. CONC. 1' - 5 1/2" @ PERIMETER 3' - 2 1/4" @ T.O. DRAIN 1/4" : 1'-0" 55" TV ABOVE FIREPLACE. PROVIDE NICHE IN STONE VENEER FOR TV BRACKET WITH POWER AND CONNECTION. SUMP PUMP 3' - 3" ELECTRICAL PANELS LIGHTING CONTROL PANELS AV EQUIPMENT RACK 4 RISERS @ 6 3/4" 3 TREADS @ 11" 4 RISERS @ 7 9/16" 3 TREADS @ 10" BATH #5 SHOWER 011B 8' - 3" CLOSET 3' - 2 5/8" 1' - 10 1/4" DRESSER FULL BED W/ TWIN ABOVE. DRAWERS BELOW BOTTOM BUNK RECLAIMED WOOD SIDING @ DASHED LINE FURNITURE BENCH BUILT-IN W/ CUSHIONS AND DRAWERS BELOW BENCH SEWER LINE 5 1/4" 5 1/4" 5 1/4" BASE CABINET W/ BUILT- IN SHELVES - MECHANICAL DUCTS ABOVE FULL BED W/ DRAWERS BELOW BROOM MOP VACUUM PROVIDE A/C GRATE. PLYWOOD W/ PAINTED FINISH ADJUSTABLE SHELVES DRYING RACK W/ LAUNDRY BASKETS BELOW 2' - 1" 003 GE 17.5 CU. FT. TOP FREEZER FRIDGE STEAM UNIT FOR MASTER. PROVIDE DRAIN. SEE A9.1 FOR 1/2" PLAN AND INT. ELEVATIONS SEE A9.1 FOR 1/2" PLAN AND INT. ELEVATIONS 10 1/2" 1 1/2" U U U 3' - 3 1/4" @ B.O. STAIRS 3' - 3 1/4" @ B.O. STEP 3' - 9 1/4" 6' - 3 3/8" 3' - 7 1/4" @ B.O. STEP T.O. CONC. @ 3' - 7 1/4" SEE SHEET A7.1 FOR 1/2" PLANS, SECTIONS, AND ELEVATIONS OF FIREPLACE EXPOSED CONC. WALL BELOW CANTILEVERED DECK AIR IN-TAKE RE: MECH PLANS 2' - 3" 16' - 10 1/2" BELOW CNTR FRIDGE 24" MICROWAVE ABOVE 001B A9.7 4 100 YEAR FLOOD PLAIN 006A 011B 010A 011C 015B 006B 1/4" : 1'-0" ROUGH IN FOR WINE ROOM COOLER UNIT ABOVE DOOR. UP 4 A6.3 CANTILEVERED CONC. DECK ABOVE PROPERT Y LI NE PROPE RTY LI NE 04 06 08 10 12 14 14 14.5 10 10 08 10 08 04 06 12 SEE LANDSCAPE SHEETS, L1 AND L2, FOR T.O. GRADE CALL OUTS 4' - 1 1/8" 3' - 9" BU I LDING SETBA CK B UI LDING SE TB AC K BUI LDING SETBACK HOSE BIB (HB) FD 3/4" +H.P. 4 7/8" FD 4 A4.5 2' - 6" 7/8" 11 3/8" U U U U POWDER ROOM AND BATH #3 DRAIN T.O. CONC. @ 4' - 8 7/8" DRAIN DISCHARGE FOR POWDER ROOM. MASTER BATH AND BATH #2 DISCHARGE DRAIN DISCHARGE FOR UPPER LEVEL LAUNDRY AND BATH #4 DRAIN DISCHARGE FOR KITCHEN 1' - 1" 5' - 0" 5 1/2" 5 1/2" 7 1/2" FLOOR PLAN GENERAL NOTES: 1. DOWNSPOUTS - RUN IN SOLID PIPE BELOW GRADE TO DAYLIGHT. (DO NOT CONNECT TO PERIMETER DRAIN SYSTEM) PROVIDE HEAT TAPE TYPICAL. 2. SLOPE SLAB @ MECHANICAL, WET STORAGE, AND CONC. MIN. 1/8":12" TO DRAINS ADJUST SLOPES AS REQUIRED 3. MOTORIZED SHADE WITH SHADE POCKETS TO BE PROVIDE AT LIVING ROOM SOUTH WINDOWS, DOOR, ALL BEDROOM WINDOWS, AND LARGE BATHROOM WINDOWS. 4. SEE A10.1-A10.3 FOR RCPs WITH SHADE VALANCE DETAIL CALL OUTS. 5. PROVIDE PERFORATED DRAIN @ PERIMETER AS SHOWN IN SECTION, DETAIL, SPEC, & SOILS REPORT RUN TO DAYLIGHT. SEE CIVIL PLANS. 6. RE: WINDOW SCHEDULE FOR WINDOWS AND DOORS W/ SHADE POCKET ABOVE. 7. SEE INTERIOR ELEVATION SHEETS FOR 1/2" = 1'-0" PLANS AND ELEVATIONS OF KITCHEN, BATHROOMS AND BUILT- INS. 8. RE: LANDSCAPE SHEETS FOR ALL SITE SPOT ELEVATIONS BEYOND EDGE OF BUILDING AND PATIOS. Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 2/4/2016 1:49:12 PM 3090 BOOTH CREEK DR. VAIL, CO A3.1 LOWER LEVEL FLOOR PLAN CWF HB REIMERS RESIDENCE 02/04/2016 TOV DRB CHANGE TO APPROVED PLANS 0' 2' 4' 8' 16' 1/4" = 1'-0" 1 LOWER LEVEL FLOOR PLAN NORTH No. Revision Date Revision Description 1 FEBRUARY 4, 2016 CHANGES TO APPROVED DRB * CONC. PATIO ADDED OUTSIDE OF LOWER LEVEL WINDOW. DRB APPROVED 2/23/2016 12:00:00 AM