Loading...
HomeMy WebLinkAboutDRB160032_A3.2_1456263300.pdfT CS A4.3 A4.4 1 1 A4.1 A4.2 1 1 FRIDGE DOUBLE OVEN W/ MICROWAVE ABOVE PANTRY CABINET MUDROOM 113 GARAGE 114 BREAKFAST NOOK 110 HEARTH ROOM 111 KITCHEN 108 MASTER BEDROOM 105 MASTER BATH 103 MASTER CLOSET 102 FRONT ENTRY 101 STAIR 116 DINING ROOM 107 LIVING ROOM 106 POWDER 112 DRESSER LOWER LEVEL PATIO BELOW SHOWER CLOSET 101B OUTDOOR LIVING ROOM 109 BUILDIN G S ETBACK B U I LDI NG SETB ACK BUILDI NG SETBACK LINE OF ENTRY ROOF ABOVE LINE OF DECK ABOVE BEST VIEW OF THE GORE RANGE 14.0° WATERFALL CLIFFS GORE RANGE GORE RANGE BUILDING FOOT PRINT OF EXISTING HOUSE BUILDING FOOTPRINT OF EXISTING HOUSE TRASH RECYCLE RECYCLE LINE OF DECK ABOVE BUILT-IN LOCKERS T.O. FINISH 11' - 11 1/4" 11' - 10 1/4" T.O. STAIR @ 11' - 8 1/2" T.O. FINISH 11' - 3 7/8" 7 3/8" 1" 6" 6" 6" 1" 3.5" RECYCLE TRASH 1' - 7" 22' - 10" 10' - 4" STEAM SHOWER T.O. GYPCRETE 11' - 10 1/2" A4.5 2 A4.5 3 1 A5.5 1 A5.7 1 A5.6 2 A5.5 A4.5 1 1 A5.1 15' - 9" 2% SLO P E 4 A5.5 2 A5.7 2 A6.1 3 A6.1 2 A6.5 6 A6.2 3 A6.2 2 A6.2 1 A6.3 1 A6.2 2 A6.3 7 A6.2 2 A6.5 5 A6.8 1 A6.1 2 A6.3 2 A6.3 A6.6 4 A6.6 3 4 A6.1 9 A6.7 1 A5.2 1 A5.3 2 A5.4 3 A5.5 1 A5.8 1 A5.9 2 RISERS @ 7 3/8" 1 TREAD @ 11" T.O. CONC. @ 10' - 1 1/8" @ GARAGE DOOR THRESHOLD Q Q Q Q Q Q Q Q Q Q W.C. 104 101B 102A 103A 105A 104A112A 113C 108B 108A 113A 113B 114A 103B TILE WOOD CARPET WOOD STONEWOOD TILE WOOD EP OXY TILE5 A6.8 SOILS TEST BORING #1 FREE WATER @ 8299.8' ON 6/10/15 GAS METER PAINTED TO MATCH STONE VENEER SOILS TEST BORING #2 FREE WATER @ 8300.9' ON 6/10/15 FD FD 1/8" : 1'-0" 1/8" : 1'-0" J-BOX DS DS DS DS DS DS DS DS 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 A A B B C C D D E E F F H H K K L L M M G1 G4 GD GD GC GC GA GA GB GB I I J J G5 G2 107 108 109 110 111 112 113 114 115 116 1' - 9 1/2"8' - 6 1/2"13' - 2" 23' - 6" 1' - 2" 1' - 0" 1' - 4"10" 12' - 3" 3' - 6" 1' - 7" 7' - 6 9/16" 6 5/16" 4' - 11 1/8" 3' - 0" 37' - 8" Q Q Q Q Q Q TV ABOVE FIREPLACE PROVIDE NICHE IN STONE VENEER FOR TV BRACKET W/ POWER AND CONNECTION 36" COOK TOP W/ WARMING DRAWER BELOW G3 DS DS CENTOR SCREEN TRACK BOILER FLUES TO BE VENTED THRU CHIMNEY CAP IN 2X8 WALL. RE: MECH PLANS LINE OF BRIDGEWAY ABOVE 5 A6.2 9 1/8" R.O. 6' - 0 1/4" 9 1/8" 1 A5.10 106 MASTER BEDROOM AND BEDROOM #3 AC UNIT ROUGH IN FOR MAKE UP AIR A/C AND WINE ROOM COOLING UNIT. HB HB HB HB H O T AN D COLD W A TER HB SURFACE PARKING(9' X 19') SURFACEPARKING(9' X 19') SURFACEPARKING(9' X 19') 1% 1% 1% BBQ 5' - 0" STEEL GAURD RAIL PREMANUFACTURED STEEL SPIRAL STAIRCASE BOULDER HEARTH WITH TOP APPROX. 15" ABOVE STONE PATIO FIREROCK 42" OUTDOOR MASONRY FIREPLACE FIREROCK 42" ARCHED TOP MASONRY FIREPLACE FLUE FROM LOWER LEVEL FIREPLACE ART U U SLOPED WALL ON EXTERIOR CUSTOM MASONLITE FIRE-BOX 49" FIREPLACE WITH 4' X 4' OPENING. IN-FLOOR WELL LIGHT. SEE RCP'S. DN UP DRAWERS BELOW Q Q 8% 4" 4" 4' - 1 1/8" 2" 4" 105 103 104 SEE A9.3 FOR 1/2" PLAN AND INT. ELEVATIONS SEE A9.2 FOR 1/2" PLAN AND INT. ELEVATIONS SEE A9.6 FOR 1/2" PLAN AND INT. ELEVATIONS 2' - 1" 1' - 0" U U 1' - 3 1/2" ELECTRICAL CLOSET 114B 3' - 3 1/4" B.O. STAIR @ 10' - 3 3/8" B.O. STEP @ 10' - 3 7/8" 6" PROPERTY LINE 100 YEAR FLOOD PLAIN 1% T.O. PAVERS @ 10' - 0 1/8" 4.5% B.O. STEP @ 9' - 7 1/8" T.O. CONC. @ 10' - 1 1/8" @ PERIMETER T.O. STONE PATIO @ 11' - 11 1/4" T.O. STONE PATIO @ 11' - 10 1/4" T.O. FINISH @ 11' - 11 1/4" T.O. STONE PATIO @ 11' - 10 1/4" T.O. FINISH @ 11' - 11 1/4" T.O. FINISHED FLOOR @ 11' - 11 1/4" T.O. PATIO @ 11' - 7 1/4" T.O. PATIO @ 11' - 7 3/4" D.W. T.O. PATIO @ 11' - 8 1/8" T.O. STAIR @ 11' - 8 3/4" T.O. STAIR @ 11' - 4 5/8" T.O. PATIO @ 11' - 6 1/2" B.O. STAIR @ 10' - 1 1/8" 1/4" / 12" T.O. PATIO @ 11' - 5 7/8" T.O. STAIR @ 11' - 5 7/8" T.O. GRADE @ 7' - 7" SLOPE 10% FOR 10' T.O. GRADE @ 7' - 0" T.O. GRADE @ 7' - 8" SLOPE 10% FOR 10' T.O. GRADE @ 10' - 6" T.O. GRADE @ 10' - 0" T.O. GRADE @ 10' - 6" SLOPE 10% FOR 10' EXISTING WALL TO BE REMOVED E 11 R ISER S @ 6 7/8 "10 TREA D @ 10 " T.O. GRADE @ 7' - 9 5/8" T.O. GRADE @ 7' - 10 3/4" B.O. STEP @ 10' - 9 7/8" SEE SHEET A7.1 FOR 1/2" PLANS, SECTIONS, AND ELEVATIONS OF FIREPLACE SEE SHEET A7.3 FOR 1/2" PLANS, SECTIONS, AND ELEVATIONS OF FIREPLACE SEE SHEET A7.2 FOR 1/2" PLANS, SECTIONS, AND ELEVATIONS OF FIREPLACE SEE SHEET A7.4 FOR 1/2" PLANS 2X8 WALL SHOWN 2X10 WALL SHOWN FOR IN WALL RETURN AIR DUCTS RE: MECH PLANS LINE OF EXISTING PATIO TO BE REMOVED. 108C 108D 114C 114B T.O. GRADE @ 4' - 0" PROPERTY LI NE EXISTING PATIO STAIR TO BE REMOVED 15 RISERS @ 7" 14 TREADS @ VARIES BUILT IN BENCH. CUBBIES ABOVE. 1% 1% 1% 1% RIDGE HIP B.O. STAIR @ 9' - 7 1/2" 1 A6.5 T.O. STEP @ 11' - 9 3/4" B.O. STEP @ 11' - 5 3/4" LINE OF EXPOSED BOARD FORMED CONC. WALL BELOW. 2' - 0" T.O. GRADE @ 10' - 5" T.O. GRADE @ 10' - 8" T.O. GRADE @ 10' - 8" 2% SLOPE DN T.O. CONC. @ 9' - 5 5/8" T.O. CONC. @ 9' - 5 5/8" PRO PERT Y LINE B.O. STAIR @ 8' - 10" T.O. STAIR @ 10' - 7" 2% VALLEY 112 101 102 EXISTING WALL TO BE REMOVED 04 06 08 10 12 14 14 14.5 12 10 10 08 10 08 04 06 E04 E06 E08 E10 E14 E12 1' - 9 3/4" 1' - 9 3/4" HOSE BIB (HB) 3' - 9 1/4" 4 A4.5 15' - 5 1/2" R.O. 3' - 0" 4' - 7 1/2" 117 U U U U DRAINS FROM ABOVE - --- 5 A8.2 4 A6.3 6" +H.P. 2 A6.2 SIM CUT STONE SILL T.O. PLYWOOD 11' - 1 5/8" T.O. GYPCRETE 11' - 3 1/8" PROVIDE T&G WOOD SIDING @ INTERIOR FD GRIPPABLE HANDRAIL @ 3'-1" ABOVE STAIR NOSING. 5 1/2" R.O. 6' - 9 3/8" 3' - 6" 9' - 0" A8.2 3 8 A6.8 T.O. PATIO @ 9' - 5 3/8" T.O. PATIO @ 9' - 5 3/8" 3' - 3" 5' - 7" 5' - 10 1/2" 4' - 5" 3' - 9 1/4" 3' - 0 1/4" 11' - 6" 9' - 4 1/4" 7' - 7 1/2" 3' - 6" 2' - 4" 7' - 6 1/2" 4' - 0 1/4" R.O. 3' - 0" 4' - 5 3/4" 4 5/8" R.O. 3' - 0" 4 5/8" 3' - 4" 4' - 4 1/2" 1' - 0 1/2" R.O. 3' - 0" 2' - 3 1/2" 14' - 0 1/2" 4' - 0 3/4" 13' - 9 3/8" 2' - 6 1/2" R.O. 2' - 8" 8" 4' - 0" 7' - 0 5/8" R.O. 3' - 2" 3' - 9 7/8" 10 1/2" R.O. 3' - 4 1/2" 8 1/8" 5' - 7 5/8" R.O. 3' - 6 3/4" 5 1/2" 6' - 9 3/4" 17' - 2 1/4" 10' - 6 1/2" 1' - 1 1/4" R.O. 5' - 10" 6 1/2" 2' - 3" 1' - 3 1/2" R.O. 3' - 2" 2' - 9 1/2" 6 7/8" 3' - 1 1/4" 1' - 0 3/8" 10' - 10 1/4" 9' - 0 1/4" 5' - 9 1/2" 6' - 0" 1' - 3 3/8" R.O. 3' - 0" 2' - 11 3/4" 9 1/4" 2' - 0" 14' - 9 3/8" 10' - 11 3/8" 2' - 7 1/8" R.O. 3' - 8" 8' - 4 1/2" R.O. 3' - 8" 0' - 3 1/2" 18' - 7 1/8" 5 1/2" 3" R.O. 25' - 9" 6 1/2" R.O. 6' - 10 3/8" 7' - 8 7/8" 3" R.O. 2' - 0 3/4" 3" R.O. 5' - 6 3/4" 3" R.O. 2' - 0 3/4" 5 1/2" 5' - 5" R.O. 6' - 2" 5' - 7 1/4" 3' - 5 3/8" R.O. 2' - 0 3/4" 2 5/8" 6' - 2" 2 5/8" R.O. 2' - 0 3/4" 2' - 10 3/8" R.O. 2' - 8 7/8" 1 1/4" R.O. 5' - 9 3/4" 4' - 4 1/8" 70.0° 110.0° 2' - 0" 8' - 4" 7 1/2" R.O. 3' - 0" 7 1/2" 6' - 1" 22' - 7" 21' - 11" 10' - 4"3"R.O. 3' - 2"8' - 10" 1' - 3 1/2"R.O . 20' - 0"1' - 3 1/2" 0' - 8 7/8" R.O. 3' - 0" 1' - 4 1/4" 9' - 7" 1' - 4" 10' - 11 3/4" R.O. 3' - 2" 10' - 5 1/4" 1' - 6" R.O. 7' - 0 3/4" 5 1/2" 6 1/8" R.O. 1' - 9 3/4" 5 1/2" R.O. 1' - 11 7/8" 1' - 0 1/8" 5 1/2" R.O. 6' - 11" 1 5/8" 8' - 5 7/8" 10 1/8" R.O. 2' - 6 3/4" 8' - 10 1/8" 11 5/8" R.O. 2' - 8 3/4" 9 1/8" 4' - 10 3/8" R.O. 5' - 0 3/4" 5' - 0 3/8" 5 1/2"2 3/8"R.O .6' - 0 "2 1/2"3 1/2" 3' - 1 1/2"8 5/16" R.O. 2' - 8 3/4" 13' - 2 1/8" 5' - 4 3/4" R.O. 2' - 6 3/4" 4' - 11 1/8"2' - 9 3/8" 8' - 6 11/16" 7' - 11 15/16" 19' - 4" 24' - 7" 27' - 8 3/4" 4' - 11" 3' - 7 1/8" 12" : 1/2" SLOPED WALL 4' - 11 1/8" 9' - 7 7/8" 3' - 6" 12' - 3" 2' - 2" 1' - 0" 5' - 10 1/2" 2' - 4" 8' - 0" 14' - 11 1/2" 27' - 0" 25' - 6" 1 7' - 4 1/2" 5' - 5 1/2" 1' - 2" 5' - 9" 2' - 4" 3' - 6 1/2" 4' - 5 1/2" 14' - 11 1/2" 1' - 0 1/2" 16' - 0" 11' - 0" 2' - 0" 9' - 3" 14' - 3" 3' - 4" 82' - 2" 2' - 4" 3' - 6 1/2" 4' - 5 1/2" 14' - 11 1/2" 1' - 0 1/2" 16' - 0" 11' - 0" 2' - 0" 9' - 3" 14' - 3" 3' - 4" 82' - 2" 12' - 3" 6' - 4" 5' - 11 7/16" 10' - 8 7/8" 4' - 0" 7' - 1" 4' - 0" 4' - 4 3/8" 1' - 11 1/2" 4' - 10 5/8" 8' - 0 1/16" 4' - 1 1/4" 7' - 2 1/2" 3' - 7 3/4" 3' - 11 7/8" 2' - 11 3/8" R.O. 2' - 8 7/8" 5' - 10 1/2" 4' - 5 1/2" 14' - 11 1/2" 1' - 9" R .O. 20' - 0"1' - 9"160.0° 70.0° 7 1/4" 5 1/2" 9 1/4" 7 1/4" 3' - 5 3/8" 5' - 5 1/2" 3' - 5 7/8" 5' - 5 3/8" 8' - 4 1/2" 70.0° 7' - 1 1/2" 1' - 11" 13' - 0 3/8" 1' - 6 3/4" 5 1/2" 5 1/2" 42" HIGH WALL 6' - 7 1/8" 4' - 7 7/8" 7 3/4" 0' - 6 3/4" 12" : 1/2" SLOPED WALL 1' - 2 11/16" R.O. 2' - 2" 7 5/16" SIM - --- - --- 10 ' - 0" 5' - 0" G G 25' X 2" FLOOR REGISTER RE: MECH PLANS T.O. PLYWOOD 11' - 8 1/4" T.O. PATIO @ 9' - 5 3/8" 6"7" 6" 10' - 0" 6' - 7 1/4" 3' - 5 1/8" 6' - 7 1/8" 1' - 6" 10' - 2 7/8" 13' - 10 5/16" 6' - 4 1/16" 17' - 6 7/8" 20' - 4 5/8" 1' - 8" 1' - 1 3/8" 1' - 5" 2' - 8 13/16" 1' - 5" 9 13/16" 7' - 10" 7' - 0 1/4" 8' - 2" 4' - 10" 2' - 3" 11' - 2" 3' - 6 5/16" 3' - 2 5/8" 10' - 1 15/16" 7' - 7 13/16" 1 1/2" 8" 6" 1 1/2" 1' - 5" 56.3° 69.7° 2' - 4 1/8" 8' - 9 3/4" 8 1/8" 2' - 1 5/8" 2X10 WALL SHOWN 3' - 9 1/2" 16' - 5 1/2" 3' - 4 1/4" 3' - 11" 6' - 4 7/16" 6' - 4 7/16" 5' - 7 3/16" 7' - 1 3/16" 5 1/2" 5' - 10 1/2" 4' - 5 1/2" 14' - 11 1/2" 17' - 0 1/2" 11' - 0" 2' - 0" 4' - 8 3/8" 11' - 7 7/8" 7' - 0 3/8" 1' - 2" 3 A6.5 5 A6.5 1" 6" 6" - --- FLOOR PLAN GENERAL NOTES: 1. DOWNSPOUTS - RUN IN SOLID PIPE BELOW GRADE TO DAYLIGHT. (DO NOT CONNECT TO PERIMETER DRAIN SYSTEM) PROVIDE HEAT TAPE TYPICAL. 2. SLOPE SLAB @ MECHANICAL, WET STORAGE, AND CONC. MIN. 1/8":12" TO DRAINS ADJUST SLOPES AS REQUIRED 3. MOTORIZED SHADE WITH SHADE POCKETS TO BE PROVIDE AT LIVING ROOM SOUTH WINDOWS, DOOR, ALL BEDROOM WINDOWS, AND LARGE BATHROOM WINDOWS. 4. SEE A10.1-A10.3 FOR RCPs WITH SHADE VALANCE DETAIL CALL OUTS. 5. PROVIDE PERFORATED DRAIN @ PERIMETER AS SHOWN IN SECTION, DETAIL, SPEC, & SOILS REPORT RUN TO DAYLIGHT. SEE CIVIL PLANS. 6. RE: WINDOW SCHEDULE FOR WINDOWS AND DOORS W/ SHADE POCKET ABOVE. 7. SEE INTERIOR ELEVATION SHEETS FOR 1/2" = 1'-0" PLANS AND ELEVATIONS OF KITCHEN, BATHROOMS AND BUILT-INS. 8. RE: LANDSCAPE SHEETS FOR ALL SITE SPOT ELEVATIONS BEYOND EDGE OF BUILDING AND PATIOS. Scale Drawn by Checked by US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Issue Date REVISION 1/4" = 1'-0" 2/18/2016 5:16:25 PM 3090 BOOTH CREEK DR. VAIL, CO A3.2 MAIN LEVEL FLOOR PLAN CWF HB REIMERS RESIDENCE 02/19/2016 PROGRESS SET 0' 2' 4' 8' 16' 1/4" = 1'-0" 1 MAIN LEVEL FLOOR PLAN NORTH No. Revision Date Revision Description DRB APPROVED 2/23/2016 12:00:00 AM