HomeMy WebLinkAboutDRB160032_A4.4_1456263300.pdfMATERIALS
1. STANDING SEAM METAL ROOF - COPPER RE: SPEC
2. SYNTHETIC SHAKE ROOF RE: SPEC
3. 6X10 WOOD RAFTERS. RE: STRUCT
4. 8X10 RAFTERS RE: STRUCT
5. 2X10 FASCIA
6. 10X14 WOOD OUTLOOK BEAM RE: STRUCT.
7. 8X12 WOOD EAVE BEAM
8. COPPER SHINGLE SIDING RE: SPEC
9. DRY STACKED STONE VENEER RE: SPEC & FINISH SCHEDULE
10. RECLAIMED VERTICAL WOOD SHIP LAP SIDING W/ NO REVEAL BETWEEN BOARDS
RE: SPEC & FINISH SCHEDULE
11. HORIZONTAL SHIP LAP SIDING W/ 1/4" REVEAL RE: SPEC & FINISH SCHEDULE
12. 3X3 WOOD TRIM
13. LIFT AND SLIDE DOOR SYSTEM
14. STEEL C-CHANNEL WINDOW HEADER. RE: STRUCT
15. PFSM CLAD PANEL SIDING PAINTED TO MATCH WINDOWS
16. RUBBLE STONE CAP W/ 10 PERCENT MIN. SLOPE AT TOP TO SHED WATER
17. STEEL BEAM. RE: STRUCT
18. 8X8 WOOD STRUT W/ KNIFE PLATE CONNECTIONS @ WALL AND LAG BOLTED TO
STEEL BEAM
19. TYPICAL STEEL HANDRAIL PAINTED CUSTOM BLUE/BLACK COLOR
20. 5" ROUND PFSM GUTTER AND 3" DOWNSPOUT. PIPE UNDERGROUND TO
DAYLIGHT OUTSIDE OF AREA OF EXCAVATION FOR FOUNDATION AND PROVIDE
POWER FOR HEAT TAPE.
21. 10X10 WOOD DECK COLUMN OVER STEEL CAP AND 4X4 HSS COLUMN BASE
22. CUSTOM STEEL CHIMNEY CAP
23. 4" THICK STONE CHIMNEY CAP
24. WOOD BEAM
25. WOOD OUTLOOK BEAM
26. CURVED GLULAM BEAM RE: STRUCT
27. STEEL SPIRAL STAIRCASE
28. PROVIDE RECESS SHADE POCKET ABOVE WINDOW
GENERAL NOTES:
1. EXTERIOR LIGHTING: SEE LIGHTING PLANS FOR ALL EXTERIOR
LIGHTING AND LIGHTING SCHEDULE
2. SEE EXTERIOR MATERIAL AND COLOR INFORMATION SHEET FOR
MORE INFORMATION ON COLORS. SEE OUTLINE SPEC AND
ARCHITECTURAL FINISH SCHEDULE.
3. ALL SNOW CLIPS (PADS) AS SHOWN ON THE ROOF AND ABOVE ALL
DOORS AND DECKS TO BE AN ENGINEERED SYSTEM PER ROOF
TYPE AND SLOPE INSTALLED PER MANUFACTURES
RECOMMENDATIONS
4. ALL DIMENSIONS / ELEVATIONS ARE FROM T.O. FINISH U.N.O.
5. WINDOW AND DOOR HEAD / SILL HEIGHTS ARE FROM T.O. FINISH.
a. B.O. WINDOW HEADER DIMENSIONS ARE MEASURED
TO THE WINDOW UNIT R.O. RE: THE WINDOW
SCHEDULE AND DETAILS FOR ACTUAL PLACEMENT
OF THE STRUCTURAL HEADER
b. MOTORIZED SHADES TO BE PROVIDE IN SHADE
POCKET @ ALL LARGE WINDOW OPENINGS
THROUGHOUT THE HOUSE. RE: WINDOW SCHEDULE
6. ALL EXTERIOR EXPOSED STEEL HEADERS, BEAM, KNIFE PLATES,
ETC, TO BE PAINTED TO MATCH THE DARK BRONZE WINDOW
COLOR.
7. EXTERIOR HANDRAIL VERTICAL AND HORIZONTAL SUPPORTS TO BE
PAINTED STEEL TO MATCH WINDOW COLOR.
8. ALL MECHANICAL VENT TO BE COPPER U.N.O.
9. SEE WINDOW SCHEDULE AND RCP FOR INDICATION OF WHICH
WINDOWS HAVE A CONCEALED SHADE POCKET.
MAIN LEVEL
FINISHED FLOOR
11' - 11 1/4"
UPPER LEVEL
FINISHED FLOOR
23' - 11 1/4"
LOWER LEVEL
FINISHED FLOOR
1' - 6 1/4"
1
A5.7
1
A5.6
2
A5.7
22
23
1
2
9
8
12
5
11
12
5
10
21
14
5
6
10
2
6
3
9
19
8
5
16
9
3
3
18
17
12
17
24
1
A6.9
2
A6.10
1
A6.8
A6.7
3
A6.1
4
1
A5.8
4
A8.1
3
A8.1
Q Q Q
20
20
J-BOX
2 1/2" / 12"
A
B C D E F G J K L H I
3' - 0" 4' - 11 1/8" 2' - 0 7/8" 6' - 0" 1' - 7" 3' - 6" 12' - 3" 10" 1' - 4"1' - 0"1' - 3"
37' - 9"
Q
MOTORIZED SHADE POCKETS
INDICATED WITH DASHED LINE
AND HATCH RE: RCP
4' - 0"
6" / 12"
2 1/2" / 12"
DOWN SPOUT B.O. HEADER @ 9' - 6 3/4"
B.O. HEADER @ 7' - 2"
B.O. HEADER @ 10' - 5 1/8"
1
A5.10
STEEL RAIL
T.O. LOWER LEVEL PATIO @ 3' - 3 1/4"
32' - 8 3/4"
15
T.O. STRUCTURE @ 36' - 0" 12' - 0"
10' - 5" 28
28
4" BATHROOM EXHAUST
VENT. RE: MECH.
T.O. STL. BEAM @ 22' - 1 1/4"
T.O. STL. BEAM @ 22' - 1 1/4"
Q
SIM
W12X30
W12X30
Scale
Drawn by
Checked by
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Issue Date
REVISION
1/4" = 1'-0"
2/4/2016
1:51:33 PM
3090
BOOTH
CREEK DR. VAIL, CO
A4.4
ELEVATION
CWF
HB
REIMERS
RESIDENCE
02/04/2016
TOV DRB CHANGE TO
APPROVED PLANS
0' 2' 4' 8' 16' 1/4" = 1'-0" 1
EAST ELEVATION
2
Exterior Southeast View
No. Revision Date
Revision
Description
1 FEBRUARY 4,
2016
CHANGES TO
APPROVED DRB
* MAIN LEVEL PATIO ADDED A DROPPED
AND CANTILEVERED DECK
* EXHAUST VENTS WERE ADDED TO
EXTERIOR WALLS.
* FIREPLACE WALL WAS CANTED
* UPPER LEVEL DECK WAS EXTENDED TO
GRID G AND SUPPORT COLUMN WAS
REMOVED.
* ELECTRICAL CLOSET WAS MOVED FROM
NORTH WALL OF GARAGE TO EAST WALL
OF GARAGE.
* WINDOW ON EAST WALL OF GARAGE
WAS REMOVED.
* UPPER LEVEL WINDOW WAS CHANGED
FROM A HORIZONTAL ORIENTATION TO A
VERTICAL ORIENTATION.
DRB
APPROVED
2/23/2016
12:00:00 AM