Loading...
HomeMy WebLinkAboutDRB160033_A5-3_1456164780.pdfMASTER LEVEL 82' - 6" ENTRY LEVEL 70' - 9" 2 A5.3 3 A5.3 LIVING RM LEVEL 81' - 0" BEDROOM 4&5 LEVEL 72' - 3" EXISTING SLAB NEW SLAB RE: STRUCT. NEW FINISH FLOOR TO MATCH EXISTING EXISTING FLAGSTONE TO BE REMOVED BUNK ROOM SLOPE 1.5 % SLOPE 1.5 % REPLACE EXISTING SLAB AND STONE PATIO WITH NEW SLAB AND STONE SLOPED TO DRAIN EXISTING RAILING TO BE REUSED SLOPE 1.5 % SLOPE 1.5 % SLOPE 1.5 % SLOPE 1.5 % NEW STONE TO SLOPE AWAY FROM NEW DECK AT 1 1/2% AND TIE INTO EXISTING STONE 1 A6.1 WALLS TO BE REPLACED W/ CMU CONSTRUCTION AND STONE TO MATCH EXISTING EXISTING DOOR TO REMAIN NEW P.T. 2X4 WALL HOLD OFF CONCRETE WALL 1" FILL CAVITY W/ 3 1/2" CLOSED CELL SPRAY FOAM REMOVE EXISTING STONE VENEER AND SAVE FOR REUSE, TYP. NEW WALL AND DOOR EXISTING CONCRETE FOUNDATION WALL TO REMAIN DESIGN-BUILD ATTACHMENT SYSTEM BY STONE MASON A6.2 5 MASTER LEVEL 82' - 6" 1 A5.3 LIVING RM LEVEL 81' - 0" BEDROOM 4&5 LEVEL 72' - 3" EXISTING SLAB TO REMAIN NEW SLAB RE: STRUCT. NEW FINISH FLOOR TO MATCH EXISTING NEW DOOR TO MATCH EXISTING DOOR AT BEDROOM 4 A6.1 1 LINE OF EXISTING FLAGSTONE TO BE REMOVED (2) NEW WINDOWS HEAD HEIGHT, MULLIONS AND SILL HEIGHT TO ALIGN WITH NEW DOOR ON ADJACENT WALL EXISTING CONCRETE FOUNDATION WALL TO REMAIN AS IS RAISE FINISH LEVEL OF DECK 3" FROM 82' -0" TO 82' - 3" SLOPE 1.5 % SLOPE 1.5 % NEW DROPPED CEILING TO ALIGN WITH B.O. FINISH OF NEW DECK STRUCTURE EXISTING WALL AND WINDOWS TO BE REMOVED BUNK ROOM EXISTING WALL TO BE DEMO'D AND REBUILT W/ CMU CONSTRUCTION EXTERIOR TO MATCH EXISTING NEW INTERIOR FURRED WALL WALL TO BE REMOVED AND REPLACED W/ CMU AND STONE TO MATCH EXISTING NEW STONE CAP SLOPED TO DRAIN EXISTING MASTER BATHROOM EXISTING FOUNDATION T.O. EXISTING WALL @ 76' - 3" EXISTING 11 7/8 RIM JOIST NEW CONCRETE/CMU WALL RE: STRUCT. P.T. WOOD BLOCKING A6.2 6 MASTER LEVEL 82' - 6" 1 A5.3 A6.1 1 LIVING RM LEVEL 81' - 0" BEDROOM 4&5 LEVEL 72' - 3" SLOPE 1.5 % SLOPE 1.5 % SLOPE 1.5 % SLOPE 1.5 % EXISTING BEDROOM EXISTING MASTER BEDROOM REPLACE EXISTING SLAB AND STONE PATIO WITH NEW SLAB AND STONE SLOPED TO DRAIN NEW DOOR TO MATCH EXISTING DOOR RE: 1/A5.2 WALLS TO BE REPLACED W/ CMU CONSTRUCTION AND STONE TO MATCH EXISTING EXISTING RAILNG TO BE REMOVED AND REUSED EXISTING FOUNDATION EXISTING 11 7/8 RIM JOIST NEW SLOPED COLORADO BUFF CAP/SILL DESIGN-BUILD ATTACHMENT SYSTEM BY STONE MASON 2 003 NEW WOOD/STEEL FRAMED WALLS, FLOORS, ROOFS AND COLUMNS SHOWN GRAY WITH SOLID BLACK LINES NEW STONE VENEER SHOWN WITH DIAGONAL HATCH NEW CMU WALL SHOWN WITH CROSS HATCH EXISTING WALL, FLOORS, ROOFS AND COLUMNS TO BE DEMOLISHED SHOWN WHITE WITH DASHED BLACK LINES EXISTING WALL, FLOORS, ROOFS AND COLUMNS TO REMAIN SHOWN WHITE WITH SOLID BLACK LINES US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 2/8/2016 3:47:21 PM VAIL, CO As indicated 84 BEAVER DAM A5.3 BUILDING SECTIONS 2-8-16 EW HB 2-8-16 DRB SET 1/2" = 1'-0" 1 Section 4 1/2" = 1'-0" 2 Section 5 1/2" = 1'-0" 3 Section 6 REVISION SCHEDULE # DESCRIPTION DATE DRB APPROVED 2/22/2016 12:00:00 AM