Loading...
HomeMy WebLinkAboutDRB160033_A6-1_1456164780.pdfSLOPE @ 1.5% 5" STONE VENEER TO MATCH EXISTING CONTINUOUS W.P. MEMBRANE 6" CMU CONSTRUCTION TO REPLACE EXISTING WOOD CONSTRUCTION RE: STRUCT. STONE CAP TO MATCH EXISTING DRAINAGE MEDIUM OVER CONT. W.P. MEMBRANE 2" - 4" MIN. STRUCTURAL SLAB OVER STEEL DECKING RE: STRUCT. STEEL BEAM RE: STRUCT. 1/2" RESILIENT CHANNEL 1X T&G DECKING TO MATCH EXISTING SLOPE @ 1% SLOPE @ 1.5% CENTER DRAIN RE: PLAN EXISTING WALL AND FLOOR ASSEMBLY REMOVE EXISTING STONE TO MIN. 18" ABOVE DECK TO INSTALL NEW W.P. MEMBRANE AND DRAINAGE 4" BEAM POCKET RE:STRUCT. CONTINUOUS STEEL CHANNEL ATTCHED TO EXISTING FLOOR STRUCTURE. HANG BEAMS ON CONTINUOUS CHANNEL RE: STRUCT. 1 1/2" - 2" FLAGSTONE TO MATCH EXISTING OVER 1/2" - 1" GROUT OVER NEW 1 1/2" SLAB W/ HEAT TUBE ATTACHED TO WELDED WIRE MESH OVER CONTINUOUS DRAINAGE MEDIUM (RE: SPEC) OVER CONT. W.P. DECK MEMBRANE (RE: SPEC) OVER STRUCTURAL SLAB W/TOP SLOPED @ MIN. 1/4:12 OVER MEDAL DECKING RE: STRUCT. 5/8" P.T. PLYWOOD LAB 2ND LAYER DRAINAGE MEDIUM OVER FLASHING OVER CONTINUOUS W.P. MEMBRANE DRAINAGE MEDIUM RE:SPEC. SLOPE @ 1.5% 5" STONE VENEER TO MATCH EXISTING EXISTING WALL STONE CAP TO MATCH EXISTING DRAINAGE MEDIUM OVER CONT. W.P. MEMBRANE EXISTING STEEL BEAM VERIFY HEIGHT AND SIZE IN FIELD SLOPE @ 1.5% EXISTING STONE VENEER REMOVE TOP STONE AS REQ'D AND LAP CONTINUOUS W.P. MEMBRANE OVER EXISTING W.P. MEMBRANE NEW CENTER DRAIN LAP W.P. MEMBRANE OVER DRAIN COLLAR EXISTING SLAB VERIFY HEIGHT AND THICKNESS IN FIELD VIF B.O. EXISTING STEEL/SLAB 70' - 5" FINISH PATIO 70' - 9" F.F. EXISTING FURRED WALL EXISTING DROPPED CEILING SLOPE @ 1% EXISTING FLOOR ASSEMBLY NEW TOPPING SLAB W/THICKENED EDGE EXISTING CORBEL GARAGE PROVIDE WEEP @ DRAINS NEW STEEL DECKING RE: STRUCT. REMOVE EXISTING STONE TO MIN. 18" ABOVE DECK TO INSTALL NEW W.P. MEMBRANE AND DRAINAGE 1 1/2" - 2" FLAGSTONE TO MATCH EXISTING OVER 1/2" - 1" GROUT OVER NEW 1 1/2" SLAB W/ HEAT TUBE ATTACHED TO WELDED WIRE MESH OVER CONTINUOUS DRAINAGE MEDIUM (RE: SPEC) OVER CONT. W.P. DECK MEMBRANE (RE: SPEC) OVER STRUCTURAL SLAB W/TOP SLOPED @ MIN. 1/4:12 OVER MEDAL DECKING RE: STRUCT. LAB 2ND LAYER DRAINAGE MEDIUM OVER FLASHING OVER CONTINUOUS W.P. MEMBRANE DRAINAGE MEDIUM RE:SPEC. SLOPE @ 1.5% 1 1/2" - 2" FLAGSTONE TO MATCH EXISTING OVER 1/2" - 1" GROUT OVER NEW 1 1/2" TOPPING SLAB W/ HEAT TUBE ATTACHED TO WELDED WIRE MESH OVER DRAINAGE MEDIUM OVER CONT. W.P. MEMBRANE CONT. W.P. MEMBRANE LAP OVER EXISTING W.P. EXISTING STEEL BEAM SLOPE @ 1.5% NEW CENTER DRAIN RE: PLAN LAP W.P. MEMBRANE OVER DRAIN COLLAR EXISTING SLAB APPEARS TO BE SLOPED TO EXTERIOR VIF B.O. EXISTING STEEL/SLAB 70' - 5" FINISH PATIO EXISTING FURRED WALL EXISTING DROPPED CEILING GARAGE 70' - 9" F.F. REMOVE EXISTING STONE TO MIN. 18" ABOVE DECK TO INSTALL NEW W.P. MEMBRANE AND DRAINAGE LAB 2ND LAYER DRAINAGE MEDIUM OVER FLASHING OVER CONTINUOUS W.P. MEMBRANE SLOPE @ 1.5% 1 1/2" - 2" FLAGSTONE TO MATCH EXISTING OVER 1/2" - 1" GROUT OVER NEW 1 1/2" SLAB W/ HEAT TUBE ATTACHED TO WELDED WIRE MESH OVER CONTINUOUS DRAINAGE MEDIUM (RE: SPEC) OVER CONT. W.P. DECK MEMBRANE (RE: SPEC) OVER STRUCTURAL SLAB OVER MEDAL DECKING RE: STRUCT. DRAINAGE MEDIUM OVER CONT. W.P. MEMBRANE CONT. W.P. DECK MEMBRANE LAP OVER EXISTING FOUNDATION W.P. EXISTING STEEL BEAM NOTE: T.O. BEAM TO BE VERIFIED IN FIELD NEW CENTER DRAIN LAP W.P. MEMBRANE OVER DRAIN COLLAR EXISTING SLAB VIF B.O. EXISTING STEEL/SLAB 70' - 5" FINISH PATIO EXISTING FURRED WALL EXISTING DROPPED CEILING NEW WALL RE: STRUCT. GARAGE NEW SLAB ON GRADE W/ THICKENED EDGE PINNED TO STRUCTURE RE: STRUCT. SLOPE @ 1.5% STEEL ANGLE TO SUPPORT NEW SLAB RE: STRUCT. NEW INTERMEDIATE STEEL STRUCTURE RE: STRUCT. PROVIDE WEEP @ DRAINS NEW STEEL DECKING RE: STRUCT. EXISTING WALL US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 2/8/2016 3:47:24 PM VAIL, CO 1 1/2" = 1'-0" 84 BEAVER DAM A6.1 DETAILS 2-8-16 EW HB 2-8-16 DRB SET 1 1/2" = 1'-0" 1 TYPICAL REBUILT DECK DETAIL 1 1/2" = 1'-0" 2 DETAIL @ SOUTH DECK OVER GARAGE 1 1/2" = 1'-0" 3 EAST PATIO @ GRADE 1 1/2" = 1'-0" 4 DETAIL @ SOUTH DECK OVER GARAGE @ GRADE REVISION SCHEDULE # DESCRIPTION DATE DRB APPROVED 2/22/2016 12:00:00 AM