HomeMy WebLinkAboutDRB160033_A6-2_1456164780.pdfLAP CONTINUOUS W.P. OVER EXISTING W.P.
70' - 5"
FINISH PATIO
GARAGE
SLOPE 1.5 %
SLOPE 1.5 %
VIF
B.O. EXISTING STEEL/SLAB
EXISTING STEEL BEAM
NOTE: T.O. BEAM TO
BE VERIFIED IN FIELD
EXISTING SLAB
EXISTING DROPPED CEILING
NEW SLAB RE: STRUCT.
1 1/2" - 2" FLAGSTONE TO MATCH EXISTING OVER 1/2" - 1" GROUT
OVER NEW 1 1/2" SLAB W/ HEAT TUBE ATTACHED TO WELDED
WIRE MESH OVER CONTINUOUS DRAINAGE MEDIUM (RE: SPEC)
OVER CONT. W.P. DECK MEMBRANE (RE: SPEC) OVER
STRUCTURAL SLAB OVER MEDAL DECKING RE: STRUCT.
NEW STEEL ANGLE RE: STRUCT.
METAL DRIP EDGE FLASHING TO MATCH ROOF
NEW STANDING SEAM METAL ROOF TO MATCH EXISTING
2X6 DOUG-FIR T&G DECKING
ROOFS TO BE PROTECTED WITH SNOW GUARDS
PER MANF. RECOMMENDATIONS PER ROOF
PITCH AND SNOW LOADS RE: SPEC
T.O. BEAM
RE: STRUCT.
CURVED 6 3/4"X9" GLULAM
RE: STRUCTURAL
5/8" PLYWOOD OVER 1X SLEEPERS TO
CREATE WIRE CHASE FOR EXTERIOR
MONOPOINT LIGHT FIXTURES RE: RCP
9"
6X8 TIMBER TO MATCH EXISTING
WOOD BRACE TO MATCH EXISTING
ATTACHED GLULAM TO TIMBER W/
COUNTER-SUNK LAG BOLTS
10 3/4"
METAL FLASHING TO MATCH ROOF
EXTENDS OVER STANDING SEAM
ROOFING 6" MIN. AND OVER 2X
BUILD UP AND UP WALL UNDER
BUILDING 6" MIN.
2X6 T&G ROOF SHEATHING W/ 1/8" X
1/8" REVEAL @ JOINTS RE: STRUCT.
6 3/4" X 9" GLU-LAM RAFTERS RE: STRUCT.
EXISTING WALL
METAL STANDING SEAM TO
MATCH EXISTING RE: SPEC
VYCOR ICE AND WATER SHIELD
- EXTENDS UP WALL 3' MIN.
RE: SPEC
REPLACE STONE VENEER TO MATCH
EXISTING AS REQ'D
DRAINAGE MEDIUM AND AIR
FILTRATION BARRIER LAPS OVER
FLASHING TO ALLOW WALL TO DRAIN
SOLID WOOD BLOCKING RE:
STRUCT.
MIN 6"
MIN 3"
INTERIOR
EXTERIOR
EXISTING DOOR
5/8" PLYWOOD OVER 1X SLEEPERS TO
CREATE WIRE CHASE FOR EXTERIOR
MONOPOINT LIGHT FIXTURES RE: RCP
REPLACE STONE VENEER TO MATCH
EXISTING AS REQ'D
CURVED STEEL ANGLE ATTACHED TO
EXISTING STRUCTURE RE: STRUCT.
1' - 0"
STEEL ANGLE LAG BOLTED INTO
SOLID BLOCKING RE: STRUCT.
DRAINAGE MEDIUM OVER
CONT. W.P. MEMBRANE
2" - 4" MIN. STRUCTURAL SLAB OVER
STEEL DECKING RE: STRUCT.
STEEL BEAM RE: STRUCT.
1/2" RESILIENT CHANNEL
1X T&G DECKING TO MATCH EXISTING
SLOPE @ 1.5%
1 1/2" - 2" FLAGSTONE TO MATCH EXISTING OVER 1/2" - 1"
GROUT OVER NEW 1 1/2" SLAB W/ HEAT TUBE ATTACHED
TO WELDED WIRE MESH OVER CONTINUOUS DRAINAGE
MEDIUM (RE: SPEC) OVER CONT. W.P. DECK MEMBRANE
(RE: SPEC) OVER STRUCTURAL SLAB W/TOP SLOPED @
MIN. 1/4:12 OVER MEDAL DECKING RE: STRUCT.
5/8" P.T. PLYWOOD
SLOPE @ 1.5%
1 1/2" - 2" FLAGSTONE TO MATCH
EXISTING OVER 1/2" - 1" GROUT OVER
NEW SLAB W/ THICKENED EDGE, SLOPED
@ MIN 1/4:12 W/ HEAT TUBE RE: STRUCT.
WRAP CONTINUOUS W.P. MEMBRANE OVER NEW SLAB
OVER STEEL DECKING UP SLAB ON GRADE AND OVER
BEAM POCKET RE: STRUCT.
CONTINUOUS BUG SCREEN STAPLED TO SOFFIT
WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN
1/2" VENT AT TOP OF THE WALL. GROUT/MORTAR UP TO
BOTTOM OF DRAINAGE MEDIUM BUT DO NOT BLOCK
DOOR SET IN A BED OF
SEALANT
SEALANT JOINT
NEW CONC. SLAB W/ THICKENED SLAB
EDGE & W/ RADIANT IN-FLOOR HEAT
W.P MEMBRANE UNDER SILL CONT. TO
B.O. CONC. THICKENED SLAB EDGE
NEW 3" STONE FLOORING ASSEMBLY - APPROX.
1 1/2" TO 2" OF STONE OVER 1" TO 1 1/2" GROUT
OVER CONC. SLAB W/ HEAT TUBE SLOPED @ MIN.
1/4:12 W/ THICKENED EDGE RE: STRUCT.
STONE VENEER BEYOND
TRIM @ WINDOW BEYOND
FINISH @ FLOOR RE:SPEC
PFSM FLASHING TO MATCH WINDOW COLOR
SEPARATE DISSIMILAR METALS FROM
STEEL HEADER WITH ICE AND WATER
SHIELD AND SEALANT
EXTERIOR
INTERIOR
OUT SWING PATIO DOOR TO
MATCH EXISTING RE:
WINDOW SCHEDULE
DRAINAGE MEDIUM OVER RIGID
INSULATION PANEL AND
CONTINUOUS OVER STEEL
ANGLE LEDGER RE: SPEC
STEEL ANGLE LEDGER EXPANSION
BOLTED TO THICKENED CONCRETE
EDGE. COAT W/ DAMP PROOFING
RE:STRUCT.
6" STEP
LINE OF EXISTING STONE PATIO TO BE REMOVED
PORTION OF EXISTING SLAB TO BE
REMOVED FOR NEW THICKENED SLAB EDGE
EXISTING SLAB TO REMAIN
4" CONT. RIGID FOAM
INSULATION PANEL UNDER SLAB
2" RIGID INSULATION
CONCRETE FOUNDATION WALL
RE: STRUCT.
WINDOW RE: WINDOW SCHEDULE
FILL W/ EXPANDING SPRAY
FOAM INSULATION AND SHIM
AS REQ'D
STONE VENEER TO MATCH EXISTING
1/2" PLYWOOD
BUILDING PAPER LAPS
OVER TOP OF FLASHING
1 1/2" MIN
LAP WATERPROOF
MEMBRANE OVER NAILING
FLANGE AND CONTINUE UP
UNDER FLASHING, UNDER
CHANNEL, AND UNDER
BUILDING PAPER
STEEL ANGLES LAG BOLTED INTO
BLOCKING AND WOOD HEADER
ATTACHMENT TO BE DESIGN BUILD
BY STONE MASON RE: STRUCT.
GRID
LINE
METAL FLASHING WITH DRIP
EDGE TO MATCH WINDOW
COLOR
HEADER RE: STRUCT.
STONE HEADER TO MATCH
EXISTING
INTERIOR TRIM TO MATCH
EXISTING
PROVIDE CAULK JOINT BETWEEN
WINDOW FRAME AND R.O. @
INTERIOR TYP.
WINDOW SET IN BED OF
SEALANT OVER W.P.
MEMBRANE
STONE VENEER TO
MATCH EXISTING
1/2" PLYWOOD
30 # BUILDING PAPER RE: SPEC.
LAP WATERPROOF
MEMBRANE OVER BLDG.
PAPER AND UNDER
WINDOW SILL
2" STONE SILL SLOPED TO
DRAIN @ 10% MIN. TO MATCH
EXISTING STONE
INTERIOR
EXTERIOR
INTERIOR TRIM TO MATCH
EXISTING
PROVIDE CAULK JOINT BETWEEN
WINDOW FRAME AND R.O. @
INTERIOR TYP.
LAP ICE AND WATER SHIELD OVER FLASHING
EXISTING FOUNDATION WALL TO REMAIN
NEW CMU WALL RE:STRUCT.
SLOPE @ 10% MIN.
NEW CMU WALL RE:STRUCT.
1/2"
1/2" AIR SPACE
SHIM AS REQ'D
SHIM AS REQ'D
1/2"
1/2" AIR SPACE
P.T. PLATE
P.T. PLATE
STEEL ANGLE EXPLANSION BOLTED
TO FOUNDATION WALL RE: STRUCT.
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date 2/8/2016 3:47:25 PM
VAIL, CO
As indicated
84 BEAVER DAM
A6.2
DETAILS
2-8-16
EW
HB
2-8-16
DRB SET
1 1/2" = 1'-0"
1
DETAIL @ DECK TRANSITION
1 1/2" = 1'-0"
2
FAMILY ROOM ROOF DETAIL
1 1/2" = 1'-0"
3
FAMILY ROOF DETAIL AT WALL
1 1/2" = 1'-0"
4 DECK TO SLAB ON GRADE TRANSITION
3" = 1'-0"
5 DOOR SILL DETAIL @ BUNKROOM
3" = 1'-0"
6 NEW WINDOW HEAD/SILL DETAIL
REVISION SCHEDULE
# DESCRIPTION DATE
DRB
APPROVED
2/22/2016
12:00:00 AM