HomeMy WebLinkAboutDRB160033_A6-2_1456164780.pdfLAP CONTINUOUS W.P. OVER EXISTING W.P. 70' - 5" FINISH PATIO GARAGE SLOPE 1.5 % SLOPE 1.5 % VIF B.O. EXISTING STEEL/SLAB EXISTING STEEL BEAM NOTE: T.O. BEAM TO BE VERIFIED IN FIELD EXISTING SLAB EXISTING DROPPED CEILING NEW SLAB RE: STRUCT. 1 1/2" - 2" FLAGSTONE TO MATCH EXISTING OVER 1/2" - 1" GROUT OVER NEW 1 1/2" SLAB W/ HEAT TUBE ATTACHED TO WELDED WIRE MESH OVER CONTINUOUS DRAINAGE MEDIUM (RE: SPEC) OVER CONT. W.P. DECK MEMBRANE (RE: SPEC) OVER STRUCTURAL SLAB OVER MEDAL DECKING RE: STRUCT. NEW STEEL ANGLE RE: STRUCT. METAL DRIP EDGE FLASHING TO MATCH ROOF NEW STANDING SEAM METAL ROOF TO MATCH EXISTING 2X6 DOUG-FIR T&G DECKING ROOFS TO BE PROTECTED WITH SNOW GUARDS PER MANF. RECOMMENDATIONS PER ROOF PITCH AND SNOW LOADS RE: SPEC T.O. BEAM RE: STRUCT. CURVED 6 3/4"X9" GLULAM RE: STRUCTURAL 5/8" PLYWOOD OVER 1X SLEEPERS TO CREATE WIRE CHASE FOR EXTERIOR MONOPOINT LIGHT FIXTURES RE: RCP 9" 6X8 TIMBER TO MATCH EXISTING WOOD BRACE TO MATCH EXISTING ATTACHED GLULAM TO TIMBER W/ COUNTER-SUNK LAG BOLTS 10 3/4" METAL FLASHING TO MATCH ROOF EXTENDS OVER STANDING SEAM ROOFING 6" MIN. AND OVER 2X BUILD UP AND UP WALL UNDER BUILDING 6" MIN. 2X6 T&G ROOF SHEATHING W/ 1/8" X 1/8" REVEAL @ JOINTS RE: STRUCT. 6 3/4" X 9" GLU-LAM RAFTERS RE: STRUCT. EXISTING WALL METAL STANDING SEAM TO MATCH EXISTING RE: SPEC VYCOR ICE AND WATER SHIELD - EXTENDS UP WALL 3' MIN. RE: SPEC REPLACE STONE VENEER TO MATCH EXISTING AS REQ'D DRAINAGE MEDIUM AND AIR FILTRATION BARRIER LAPS OVER FLASHING TO ALLOW WALL TO DRAIN SOLID WOOD BLOCKING RE: STRUCT. MIN 6" MIN 3" INTERIOR EXTERIOR EXISTING DOOR 5/8" PLYWOOD OVER 1X SLEEPERS TO CREATE WIRE CHASE FOR EXTERIOR MONOPOINT LIGHT FIXTURES RE: RCP REPLACE STONE VENEER TO MATCH EXISTING AS REQ'D CURVED STEEL ANGLE ATTACHED TO EXISTING STRUCTURE RE: STRUCT. 1' - 0" STEEL ANGLE LAG BOLTED INTO SOLID BLOCKING RE: STRUCT. DRAINAGE MEDIUM OVER CONT. W.P. MEMBRANE 2" - 4" MIN. STRUCTURAL SLAB OVER STEEL DECKING RE: STRUCT. STEEL BEAM RE: STRUCT. 1/2" RESILIENT CHANNEL 1X T&G DECKING TO MATCH EXISTING SLOPE @ 1.5% 1 1/2" - 2" FLAGSTONE TO MATCH EXISTING OVER 1/2" - 1" GROUT OVER NEW 1 1/2" SLAB W/ HEAT TUBE ATTACHED TO WELDED WIRE MESH OVER CONTINUOUS DRAINAGE MEDIUM (RE: SPEC) OVER CONT. W.P. DECK MEMBRANE (RE: SPEC) OVER STRUCTURAL SLAB W/TOP SLOPED @ MIN. 1/4:12 OVER MEDAL DECKING RE: STRUCT. 5/8" P.T. PLYWOOD SLOPE @ 1.5% 1 1/2" - 2" FLAGSTONE TO MATCH EXISTING OVER 1/2" - 1" GROUT OVER NEW SLAB W/ THICKENED EDGE, SLOPED @ MIN 1/4:12 W/ HEAT TUBE RE: STRUCT. WRAP CONTINUOUS W.P. MEMBRANE OVER NEW SLAB OVER STEEL DECKING UP SLAB ON GRADE AND OVER BEAM POCKET RE: STRUCT. CONTINUOUS BUG SCREEN STAPLED TO SOFFIT WRAPPED OVER AIR VENT MATERIAL TO CREATE MIN 1/2" VENT AT TOP OF THE WALL. GROUT/MORTAR UP TO BOTTOM OF DRAINAGE MEDIUM BUT DO NOT BLOCK DOOR SET IN A BED OF SEALANT SEALANT JOINT NEW CONC. SLAB W/ THICKENED SLAB EDGE & W/ RADIANT IN-FLOOR HEAT W.P MEMBRANE UNDER SILL CONT. TO B.O. CONC. THICKENED SLAB EDGE NEW 3" STONE FLOORING ASSEMBLY - APPROX. 1 1/2" TO 2" OF STONE OVER 1" TO 1 1/2" GROUT OVER CONC. SLAB W/ HEAT TUBE SLOPED @ MIN. 1/4:12 W/ THICKENED EDGE RE: STRUCT. STONE VENEER BEYOND TRIM @ WINDOW BEYOND FINISH @ FLOOR RE:SPEC PFSM FLASHING TO MATCH WINDOW COLOR SEPARATE DISSIMILAR METALS FROM STEEL HEADER WITH ICE AND WATER SHIELD AND SEALANT EXTERIOR INTERIOR OUT SWING PATIO DOOR TO MATCH EXISTING RE: WINDOW SCHEDULE DRAINAGE MEDIUM OVER RIGID INSULATION PANEL AND CONTINUOUS OVER STEEL ANGLE LEDGER RE: SPEC STEEL ANGLE LEDGER EXPANSION BOLTED TO THICKENED CONCRETE EDGE. COAT W/ DAMP PROOFING RE:STRUCT. 6" STEP LINE OF EXISTING STONE PATIO TO BE REMOVED PORTION OF EXISTING SLAB TO BE REMOVED FOR NEW THICKENED SLAB EDGE EXISTING SLAB TO REMAIN 4" CONT. RIGID FOAM INSULATION PANEL UNDER SLAB 2" RIGID INSULATION CONCRETE FOUNDATION WALL RE: STRUCT. WINDOW RE: WINDOW SCHEDULE FILL W/ EXPANDING SPRAY FOAM INSULATION AND SHIM AS REQ'D STONE VENEER TO MATCH EXISTING 1/2" PLYWOOD BUILDING PAPER LAPS OVER TOP OF FLASHING 1 1/2" MIN LAP WATERPROOF MEMBRANE OVER NAILING FLANGE AND CONTINUE UP UNDER FLASHING, UNDER CHANNEL, AND UNDER BUILDING PAPER STEEL ANGLES LAG BOLTED INTO BLOCKING AND WOOD HEADER ATTACHMENT TO BE DESIGN BUILD BY STONE MASON RE: STRUCT. GRID LINE METAL FLASHING WITH DRIP EDGE TO MATCH WINDOW COLOR HEADER RE: STRUCT. STONE HEADER TO MATCH EXISTING INTERIOR TRIM TO MATCH EXISTING PROVIDE CAULK JOINT BETWEEN WINDOW FRAME AND R.O. @ INTERIOR TYP. WINDOW SET IN BED OF SEALANT OVER W.P. MEMBRANE STONE VENEER TO MATCH EXISTING 1/2" PLYWOOD 30 # BUILDING PAPER RE: SPEC. LAP WATERPROOF MEMBRANE OVER BLDG. PAPER AND UNDER WINDOW SILL 2" STONE SILL SLOPED TO DRAIN @ 10% MIN. TO MATCH EXISTING STONE INTERIOR EXTERIOR INTERIOR TRIM TO MATCH EXISTING PROVIDE CAULK JOINT BETWEEN WINDOW FRAME AND R.O. @ INTERIOR TYP. LAP ICE AND WATER SHIELD OVER FLASHING EXISTING FOUNDATION WALL TO REMAIN NEW CMU WALL RE:STRUCT. SLOPE @ 10% MIN. NEW CMU WALL RE:STRUCT. 1/2" 1/2" AIR SPACE SHIM AS REQ'D SHIM AS REQ'D 1/2" 1/2" AIR SPACE P.T. PLATE P.T. PLATE STEEL ANGLE EXPLANSION BOLTED TO FOUNDATION WALL RE: STRUCT. US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 2/8/2016 3:47:25 PM VAIL, CO As indicated 84 BEAVER DAM A6.2 DETAILS 2-8-16 EW HB 2-8-16 DRB SET 1 1/2" = 1'-0" 1 DETAIL @ DECK TRANSITION 1 1/2" = 1'-0" 2 FAMILY ROOM ROOF DETAIL 1 1/2" = 1'-0" 3 FAMILY ROOF DETAIL AT WALL 1 1/2" = 1'-0" 4 DECK TO SLAB ON GRADE TRANSITION 3" = 1'-0" 5 DOOR SILL DETAIL @ BUNKROOM 3" = 1'-0" 6 NEW WINDOW HEAD/SILL DETAIL REVISION SCHEDULE # DESCRIPTION DATE DRB APPROVED 2/22/2016 12:00:00 AM