HomeMy WebLinkAboutDRB16-0155_G-000_1478905516.pdf salti OF go„
1 2 3 4 5 6 ic-i`jah .,
... 4
ARCHITECTURAL ABBREVIATIONS ,...... i
DRB
APPROVED
5/18/2016
A F P 12:00:00 AM
A/C AIR CONDITIONING F/F FACE TO FACE PBD PARTICLEBOARD
ABV ABOVE FA FIRE ALARM PCF POUNDS PER CUBIC FOOT
ACST ACOUSTIC,ACOUSTICAL FAAP FIRE ALARM ANNUNICATOR PANEL PCP PORTLAND CEMENT PLASTER
ADA AMERICANS WITH DISABILITIES ACT FACP FIRE ALARM CONTROL PANEL PLAM PLASTIC LAMINATE
ADJ ADJUSTABLE FCO FLOOR CLEAN OUT PLBG PLUMBING
ADJT ADJACENT FD FLOOR DRAIN PLYWD PLYWOOD
AFF ABOVE FINISH FLOOR FDC FIRE DEPARTMENT CONNECTION PREFAB PREFABRICATED
VAIL MOUNTAIN SCHOOL
ALT ALTERNATE FDTN FOUNDATION PREFIN PREFINISHED
ALUM ALUMINUM FE FIRE EXTINGUISHER PRKG PARKING
ANOD ANODIZED FEC FIRE EXTINGUISHER CABINET PSF POUNDS PER SQUARE FOOT
ARCH ARCHITECT,ARCHITECTURAL FF FINISH FACE PSI POUNDS PER SQUARE INCH
E ASPH ASPHALT FFE FINISH FLOOR ELEVATION PT PAINT
ASSY ASSEMBLY FH FIRE HYDRANT PTD PAPER TOWEL DISPENSER
O
AUTO AUTOMATIC FHC FIRE HOSE CABINET PTN PARTITION hord I coolan mI acht
FIN FINISH PVC POLYVINYL CHLORIDE
BATT BATT INSULATION FIXT FIXTURE O
BKR BACKER ROD FLR FLOOR QT QUARRY TILE
BD BOARD FOF FACE OF FINISH QTB QUARRY TILE BASE
BF BOTH FACES FOS FACE OF STUD QTY QUANTITY 3000 BOOTH FALLS RD
BLDG BUILDING FR FRAME OR
BLKG BLOCKING FRP FIBERGLASS REINFORCED PLASTIC R RADIUS, RISER
BLW BELOW FT FOOT R- THERMAL RESISTANCE VAIL, CO 81657
BM BEAM O FUR FURRING RA RETURN AIR 1331 Nineteenth Street P 303.607.0977
BN BULLNOSE RB RUBBER BASE Denver, CO. 80202 www.hcm2.com
BOS BOTTOM OF STEEL GA GAGE RD ROOF DRAIN
BOT BOTTOM GALV GALVANIZED RDL ROOF DRAIN LEADER
BRG BEARING GB GRAB BAR RE: REFER TO
BS BOTH SIDES GL GLASS REINF REINFORCE
BSMT BASEMENT GLU LAM GLUED LAMINATED WOOD REQD REQUIRED CONSULTANT:
BTWN BETWEEN GLAZ GLAZING REV REVISION
BUR BUILT UP ROOFING O GYP GYPSUM RM ROOM
BW BOTHISSUED FOR CONSTRUCTION DOCUMENTS
BYND BEYOND HB HOSE BIB RPM REVOLUTIONS PRE MINUTE
OC HDR HEADER ®RTU ROOF TOP UNIT
CG CORNER GUARD HDW HARDWARE S
CIP CAST IN PLACE HDWD HARDWOOD SECT SECTION
CJ CONTROL JOINT HM HOLLOW METAL SF SQUARE FOOT, FEET
CL CENTER LINE HDRL HANDRAIL SA SUPPLY AIR 03/15/16
CLG CEILING HORIZ HORIZONTAL SAT SUSPENDED ACOUSTICAL TILE
CLST CLOSET HP HORSEPOWER SB SPLASH BLOCK
CLR CLEAR HT HEIGHT SCHED SCHEDULE
CLRM CLASSROOM HVAC HEATING VENTILATING &AIR CONDITIONING SCP SCUPPER
CMU CONCRETE MASONRY UNIT HW HOT WATER SD SOAP DISPENSER
CO COMPANY O HYD HYDRANT SOG SLAB ON GRADE
COL COLUMN SGFT STRUCTURAL GLAZED FACED TILE
CONC CONCRETE ID INSIDE DIAMETER SHT SHEET
CONT CONTINUE INCL INCLUDED SHTHG SHEATHING
CONTR CONTRACTOR INSUL INSULATION SIM SIMILAR
COORD COORDINATEINT INTERIOR SJ SLIP JOINT
CORR CORRIDOR JO SLDG SLIDING SHEET INDEX EXTERIOR SCOPE OF WORK.
CPT CARPET JST JOIST SLNT SEALANT
D CRS COURSE(S)SOK SND SANITARY NAPKIN DISPENSER INDEX GENERAL SHEETS
CSWK CASEWORK K KELVIN SNDU SANITARY NAPKIN DISPOSAL UNIT VAIL MOUNTAIN SCHOOL IS RENOVATING THEIR LIBRARY. THE LIBRARY IS ON
CT CERAMIC TILE kW KILOWATT SPEC SPECIFICATION THE NORTH SIDE OF THE BUILDING, TUCKED UP AGAINST A COURT YARD PATIO
CTR CENTER OL ANGLE SQ SQUARE G-000 COVER SHEET AREA. SEE PLAN FOR REFERENCE. A PART OF THIS RENOVATION IS TO ADD A
CTV CABLE TELEVISION SST STAINLESS STEEL
CU CUBIC LAV LAVATORY STC SOUND TRANSMISSION CLASS DOOR FROM THE LIBRARY DIRECTLY TO THE EXTERIOR PATIO. THE INTENT
CUH CABINET UNIT HEATER LBR LUMBER STD STANDARD WOULD BE TO LOCATE THE NEW DOOR IN AN EXISTING WINDOW OPENING. THIS "_,
CW COLD WATER PIPING LF LINEAR FEET(FOOT) STL STEEL COL04:4--..,,_,
`:
p LIB LIBRARY WOULD REQUIRE REMOVING THE WINDOW AND A PORTION OF THE EXTERIOR
STOR STORAGE
DBL DOUBLE LINO LINOLEUM STRUCT STRUCTURAL INDEX ARCHITECTURAL SHEETS WALL IMMEDIATELY BELOW THE WINDOW. THE EXISTING WINDOW TO BE Ivrwrillpf4106:,0 _i,
•
DEPTDEPARTMENT LKR LOCKER SUSP SUSPEND(ED) REMOVED IS INDICATED IN DETAILS D1 AND D3 ON SHEET A-200. IN ITS PLACE, AN ..DTL DETAIL LL LIVE LOAD ' t �A-200 EXTERIOR ELEVATIONS h� �.� ,_ �7. ; .�
DF DRINKING FOUNTAIN LLH LONG LEG HORIZONTAL ALUMINUM DOOR WITH GLAZING AND TRANSOM WILL BE ADDED, AS INDICATED ,
ttti1,t.c,
DIA DIAMETER LLV LONG LEG VERTICAL O IN DETAIL B3 OF SHEETA-200. THE NEW ALUMINUM DOOR WILL MATCH THE M " '-2 1-..
DIM DIMENSION LT LIGHT T&G TONGUE &GROOVE COLOR OF THE EXISTING WINDOW FRAMES AND THE OTHER EXISTING T` k'�'
DISP DISPENSER LVR LOUVER TD TOWEL DISPENSER
DL DEAD LOAD - 'MAX TEL TELEPHONE °� fs�_ \:1'...'N
, '�
DMPF DAMPROOFING MAXIMUM THK THICKNESS ALUMINUM DOORS. ' �'`�
DN DOWN MECH MECHANICAL TO TOP OF
DR DOOR MEMB MEMBRANE TOC TOP OF CONCRETE
DS DOWNSPOUT MFD MANUFACTURED TOM TOP OF MASONRY PROJECT:
DW DISHWASHER MFR MANUFACTURER TOS TOP OF STEEL
DWG DRAWING MIN MINIMUM TOW TOP OF WALL
--_- DWG
MIRR MIRROR TPD TOILET PAPER DISPENSER VAIL MO U N TAI N
E EAST MISC MISCELLANEOUS TYP TYPICAL
EA EACHUMO MOLDINGASSCHOOL
ED EDUCATION MO MASONRY OPENING UNFIN UNFINISHED
EJ EXPANSION JOINT MTD MOUNTED UON UNLESS OTHERWISE NOTED
EL ELEVATION MTL METAL UR URINAL
ELEC ELECTRICAL O O
ELEV ELEVATOR NA NOT APPLICABLE VAR VARIES,VARIABLE
ENCL ENCLOSURE NONCOM NONCOMBUSTIBLE VCT VINYL COMPOSITION TILE
ENGR ENGINEER NIC NOT IN CONTRACT VERT VERTICAL
EPDM ETHYLENE PROPYLENE DIENE MONOMER NO NUMBER VEST VESTIBULE
EQ EQUAL NOM NOMINAL VIF VERIFY IN FIELD 3000 BOOTH FALLS RD
EQUIP EQUIPMENT NRC NOISE REDUCTION COEFFICIENT VTR VENT THROUGH ROOF VAIL, CO 81657
EWC ELECTRIC WATER COOLER NTS NOT TO SCALE VWC VINYL WALL COVERING
EWH ELECTRIC WATER HEATER
O O
EXC EXCAVATE OA OVERALL W WEST
EXIST EXISTING OC ON CENTER W/ WITH
OWNER:
C EF EXHAUST FAN OD OUTSIDE DIAMETER W/O WITHOUT
EXP EXPANSION OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED WB WOOD BASE VAIL MOUNTAIN
EXT EXTERIOR OF/OI OWNER FURNISHED/OWNER INSTALLED WBL WOOD BLOCKING ��
OH OVERHEAD WC WATER CLOSET
OPP OPPOSITE WCO WALL CLEAN OUT _
OPNG OPENING WD WOOD —
SCHOOL
ORD OVERFLOW ROOF DRAIN WF WIDE FLANGE _ —
WP WORKING POINT
WSCT WAINSCOT I �fil—IMMIll ,,,,,,,,,,,. �:
OWWF WELDED WIRE FABRIC II j 1=fts -'
YD YARD �_
LI r,
7_„44.10;
1 _I3000 BOOTH FALLS RD
PROJECT TEAM ARCHITECTURAL LEGEND VAIL, CO 81657
,�_ IIi9I� I � "1111:407.7:
i I, I i ISSUE:
I �� —ARCHITECT. coNCRETE // BRICKII� I 03/15/16 ISSUED FOR CONSTRUCTION
�� l __ DOCUMENTS
HERD COPLAN MACHT CMU ROUGH LUMBER I
i� I
4
1331 19th ST. 1 i --
DENVER, CO. 80202 �� •���������� PLYWOOD z/�j FINISH LUMBER �I� IPh: 303-607-0977 __ �, �. 071
Fax: 303 607 0767 ��GYPSUM RIGID INSULATION jI ®
II
URL: www.hcm2.com fIr
��jTE V
-
STEEL BATT INSULATION I iii
Irl , rv,j 11.1111111111 las i a i jill
_ ILEI _�at II __DETAIL NUMBER 117
:■■■ 111111111!
'
lin
1
STRUCTURAL: �� �win! _ _ IIIMONROE & NEWELL ENGINEERS, INC. '— ■ '
70BENCHMARK ROAD, SUITE 2 4 X A WINDOW TAG C oC O 0 ■■■ l■■■ 1---1 ..... _
EXTERIOR ELEVATION ■■■■■■■■■u■■■ ■■■■•■ l /\ RE /\ OF `/\/ORK I
71:
AVON, CO 81620 DOOR TAG f ' ".
0 A A �/ ,/A XXX ��_m�SHEET 101 r '�— — —-- i -- ___Ph: 970-949-7768 — DETAIL NUMBER ■■■ aFax: 970 949 4054 NUMBER 054000.D01 KEYNOTE TAG 1��� _ ry■■■■■■URL: WWW.MONROE NEWELL.COM . kB BUILDING SECTION I == ■2-6A PARTITION TAG ��� 0
0
SHEET DETAIL NUMBER ❑ Li ;,
MECHANICAL: NUMBER ,,� ' J6 I -� �_„ . � - _� /� 1� -- Ni � u _
ii b
BEAU DIN GANZE CONSULTING ENGINEERS, INC. `®, 1 REVISION TAG j
III —1114
i
222 CHAPEL PLACE, UNIT AC 201 WALL SECTION DETAIL NUMBER r _4=j111;1111411111
�I
AVON, CO 81620 = • � ' ir—
SHEET XX, I m 1 lull I " Q-- 0 - 01= �s1� • i UHH t.....$ 2---rn
Ph: 970-949-6108 NUMBER XX--• - DETAIL NUMBER DETAIL CALLOUT '1 2,- 1 ��/ �� �� ipt LI
AXX
, r___
URL: WWW.BGCE.COM SHEET NUMBER I ��p II II
XX A-XXX XX ����� I\I 0 ❑■ _ _ a
Ir. _
INTERIOR ELEVATION i .9 �T T�II il n�ti I i I _ d
ELECTRICAL: SHEET XX ; /IIr'
- a _ --I II
NUMBERl Q _ _ — l I_ �- • • ; I n
BEAUDIN GANZE CONSULTING ENGINEERS, INC. U ■■■■I I -- v � •,.7— f L
222 CHAPEL PLACE, UNIT AC 201 __ _- _ L
1 l
Or,
AVON, CO 81620 ■ — �.3 ••� — VI
1
II I
L T _'
Ph: 970-949-6108 - "�
••"moi•• i_ .•ice � II�
URL: WWW.BGCE.COM ii
' ��� �i��ii r•��'woo �•y
VICINITY MAP � il
(11j ,,t r i _.���._ / iiim-
I— _ 11 ,!I::::is Ljh I DRAWING INFORMATION:
a/
II Wil
rl , PROJECT NO: 11529.000
1 1 /
T2 Il 1
DRAWN BY: RF
7 CHECKED BY: AW
N • Booth Fells treilhead
O C3 1
I CP
o Booth1
- � I _ n,r APPROVED BY: AW
U Creek Trail I ^ . .
��—a° �I
SHEET TITLE:
0 A 8o,�� ¢� 414COVER SHEET
_ OVERALL FIRST FLOOR PLAN (FOR REFERENCE)
1
�a`.?Fed Vail Mourrtain School 3/64" = 1'-0"
�, ch Rd
l-7D • Sera Schools rP
Frontage Rd 2
CV - _ r-713Frontage Ftd
- - 1-70 Frorstr
s
rn 0 td E 05- i
Aspen ,, v�
LL
Booth'C. Go
r�
CB7r Cat
UC, G _000
(7\j '%
_J Gote • Simeon Properties
• Cfl
U in 0
SHEET OF
1 2 3 4 1 5 1 6