HomeMy WebLinkAboutB14-0145_E.310_1398809700.pdfFixture
Type
Lamp Type Quantity Fixture
Type
Lamp Type Quantity
HL-1 INCANDESCENT 4 D2 LED 10
E1 LED 1
ID1 LED 2
Incandescent Total: 4 High-Efficacy Total: 13
Percent High-Efficacy: 76.47% (must be minimum of 50%)
IECC 2009 CALCULATION - UNIT 310
Incandescent Fixtures High Efficacy Fixtures
PROJECT: LIONSQUARE EAST PROJECT#: 11055
CLIENT: MELICK ASSOCIATES ENGINEER: DCF
DESCRIPTION: PANEL UNIT 310 VOLTAGE: 120/208V, 1P, 3W
MOUNTING: RECESSED MAINS: 150A MLO
TYPE: QO RESIDENTIAL AIC: SERIES RATE TO 42k
PHASE PHASE
DESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTION
(E) KITCHEN 1500 20 1 1 2 2 50 4000 (E) RANGE
(E) KITCHEN 1500 20 1 3 4 4000 "
(E) DISH W DISPOSAL 1200 20 1 5 6 1 20 1200 (E) LIGHTING
(E) LIVING ROOM 1080 20 1 7 8 1 20 1490 (E) BED BATH
(E) LIGHTING 1200 20 1 9 10 1 20 1490 (E) BED BATH
(E) DRYER 2500 30 2 11 12 1 20 1440 (E) LOFT
" 2500 13 14 1 20 1440 LOFT BR NEW REC(8)
(E) WASHER 1000 20 1 15 16 1 20 360 LOFT FUTURE BATH REC(2)
FUTURE BATH EF/HL 271 20 1 17 18 1 20 1260 LOFT BR NEW REC(7)
(E) AV REC 180 20 1 19 20 1 20 360 LOFT BATH REC (2)
E. LIVING ROOM REC(8) 1440 20 1 21 22 0 SPACE
LAUNDRY CIRCUIT 1500 20 1 23 24 0 SPACE
UC REFRIGERATOR 800 20 1 25 26 0 SPACE
COFFEE REC 180 20 1 27 28 0 SPACE
MICROWAVE 1000 20 1 29 30 0 SPACE
SPACE 0 31 32 0 SPACE
SPACE 0 33 34 0 SPACE
SPACE 0 35 36 0 SPACE
SPACE 0 37 38 0 SPACE
SPACE 0 39 40 0 SPACE
SPACE 0 41 42 0 SPACE
LOAD CALCULATION SUMMARY PANEL IS EXISTING FROM BASE BUILDING CONSTRUCTION.
NOTE: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER PROTECTION AT BEDROOM RECEPTACLE CIRCUITS.
CALCULATED POWER FACTOR: 1.00 BREAKERS MUST BE SERIES RATED WITH FEEDER BREAKER TO 42k AIC.
CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS
APPLIANCES 2200 11 1650 8
LIGHTING & RECEPT. 19320 93 8712 42
MECHANICAL 121 1 133.5 1
KITCHEN OVEN & DRYER 13250 64 11650 56
TOTAL 34891 168 22146 106
TAG DESCRIPTION LOAD VOLTAGE PHASE WIRE SIZE (CU) CONNECTION CIRCUIT BREAKER REMARKS
THERMAL
EF-1 EXHAUST FAN #1 21 W 120 1 (2 #12, 1 #12G) 1/2"C OVERLOAD 20A1P
SWITCH
MECHANICAL SCHEDULE
NOTE: EC TO VERIFY ELECTRICAL REQUIREMENTS FOR ALL MECHANICAL EQUIPMENT PRIOR TO ROUGH-IN.
TAG DESCRIPTION LOAD VOLTAGE PHASE WIRE SIZE (CU) CONNECTION CIRCUIT BREAKER REMARKS
HEAT LAMP/DOWNLIGHT #1. IC- THERMAL 250W BR40 HEAT LAMP & 75W
HL-1 RATED. EC TO PROVIDE 325 W 120 1 (2 #12, 1 #12G) 1/2"C OVERLOAD 20A1P PAR30 FLOOD LAMP. PROVIDE
NUTONE #9422P. SWITCH TENT TO MAINTAIN FIRE RATING.
HEAT LAMP SCHEDULE
NOTE: EC TO VERIFY ELECTRICAL REQUIREMENTS FOR ALL MECHANICAL EQUIPMENT PRIOR TO ROUGH-IN.
TYPE DESCRIPTION MANUFACTURER CATALOG NUMBER MOUNTING NO LAMP VOLTS DIMENSIONS REMARKS
4" RECESSED OPEN LED DOWNLIGHT, DIMMABLE,
D2 IC RATED, SMOOTH WHITE TRIM CREE RC6 & LR6 & LT6WH RECESSED N/A 10.5W LED, 2700K 120 7.5" L X 12.5" W X 7.5" H
ADD ALT TO TYPE D2: 4" RECESSED OPEN LED ADD ALTERNATE TO TYPE D2.
D2A DOWNLIGHT, DIMMABLE, IC RATED, WHITE BAFFLE JUNO IC1LEDG3-27K-1 & 14W-WH RECESSED N/A 11W LED, 2700K 120 9-1/2" L X 6-3/4" W X 6" H
EXISTING RECESSED INCANDESCENT FIXTURE TO REVIEW WITH ENGINEER IF
D8 BE REUSED AS TAGGED ON PLAN - VERIFY EXISTING EXISTING RECESSED 1 EXISTING 120 EXISTING (E) FIXTURE IS NOT IC-RATED
FIXTURE IS IC & AIRTIGHT PER IECC AND AIRTIGHT.
COMPACT FLUORESCENT WALL SCONCE, WET FIXTURE IS EXISTING FROM
E1 LOCATION, PROVIDED IN BASE BUILDING PHASE, N/A N/A WALL 1 26W CFL 120 N/A BASE BUILDING PHASE -
SHOWN FOR REFERENCE ONLY CIRCUIT AS SHOWN
ID1 SCONCE/VANITY LIGHT WITH HIGH EFFICACY LAMP BY OTHERS BY OTHERS WALL TBD SCREW-IN LED - TBD 120 TBD
LUMINAIRE SCHEDULE - UNIT 310
NOTE: ALTERNATE EQUIVALENT LIGHTING PACKAGES ACCEPTED WITH ENGINEER'S REVIEW OF SUBMITTAL. FIXTURES MARKED "E" ARE EXISTING TO REMAIN IN PLACE.
04/29/14