HomeMy WebLinkAboutB14-0145_E.310_1398809700.pdfFixture Type Lamp Type Quantity Fixture Type Lamp Type Quantity HL-1 INCANDESCENT 4 D2 LED 10 E1 LED 1 ID1 LED 2 Incandescent Total: 4 High-Efficacy Total: 13 Percent High-Efficacy: 76.47% (must be minimum of 50%) IECC 2009 CALCULATION - UNIT 310 Incandescent Fixtures High Efficacy Fixtures PROJECT: LIONSQUARE EAST PROJECT#: 11055 CLIENT: MELICK ASSOCIATES ENGINEER: DCF DESCRIPTION: PANEL UNIT 310 VOLTAGE: 120/208V, 1P, 3W MOUNTING: RECESSED MAINS: 150A MLO TYPE: QO RESIDENTIAL AIC: SERIES RATE TO 42k PHASE PHASE DESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTION (E) KITCHEN 1500 20 1 1 2 2 50 4000 (E) RANGE (E) KITCHEN 1500 20 1 3 4 4000 " (E) DISH W DISPOSAL 1200 20 1 5 6 1 20 1200 (E) LIGHTING (E) LIVING ROOM 1080 20 1 7 8 1 20 1490 (E) BED BATH (E) LIGHTING 1200 20 1 9 10 1 20 1490 (E) BED BATH (E) DRYER 2500 30 2 11 12 1 20 1440 (E) LOFT " 2500 13 14 1 20 1440 LOFT BR NEW REC(8) (E) WASHER 1000 20 1 15 16 1 20 360 LOFT FUTURE BATH REC(2) FUTURE BATH EF/HL 271 20 1 17 18 1 20 1260 LOFT BR NEW REC(7) (E) AV REC 180 20 1 19 20 1 20 360 LOFT BATH REC (2) E. LIVING ROOM REC(8) 1440 20 1 21 22 0 SPACE LAUNDRY CIRCUIT 1500 20 1 23 24 0 SPACE UC REFRIGERATOR 800 20 1 25 26 0 SPACE COFFEE REC 180 20 1 27 28 0 SPACE MICROWAVE 1000 20 1 29 30 0 SPACE SPACE 0 31 32 0 SPACE SPACE 0 33 34 0 SPACE SPACE 0 35 36 0 SPACE SPACE 0 37 38 0 SPACE SPACE 0 39 40 0 SPACE SPACE 0 41 42 0 SPACE LOAD CALCULATION SUMMARY PANEL IS EXISTING FROM BASE BUILDING CONSTRUCTION. NOTE: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER PROTECTION AT BEDROOM RECEPTACLE CIRCUITS. CALCULATED POWER FACTOR: 1.00 BREAKERS MUST BE SERIES RATED WITH FEEDER BREAKER TO 42k AIC. CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS APPLIANCES 2200 11 1650 8 LIGHTING & RECEPT. 19320 93 8712 42 MECHANICAL 121 1 133.5 1 KITCHEN OVEN & DRYER 13250 64 11650 56 TOTAL 34891 168 22146 106 TAG DESCRIPTION LOAD VOLTAGE PHASE WIRE SIZE (CU) CONNECTION CIRCUIT BREAKER REMARKS THERMAL EF-1 EXHAUST FAN #1 21 W 120 1 (2 #12, 1 #12G) 1/2"C OVERLOAD 20A1P SWITCH MECHANICAL SCHEDULE NOTE: EC TO VERIFY ELECTRICAL REQUIREMENTS FOR ALL MECHANICAL EQUIPMENT PRIOR TO ROUGH-IN. TAG DESCRIPTION LOAD VOLTAGE PHASE WIRE SIZE (CU) CONNECTION CIRCUIT BREAKER REMARKS HEAT LAMP/DOWNLIGHT #1. IC- THERMAL 250W BR40 HEAT LAMP & 75W HL-1 RATED. EC TO PROVIDE 325 W 120 1 (2 #12, 1 #12G) 1/2"C OVERLOAD 20A1P PAR30 FLOOD LAMP. PROVIDE NUTONE #9422P. SWITCH TENT TO MAINTAIN FIRE RATING. HEAT LAMP SCHEDULE NOTE: EC TO VERIFY ELECTRICAL REQUIREMENTS FOR ALL MECHANICAL EQUIPMENT PRIOR TO ROUGH-IN. TYPE DESCRIPTION MANUFACTURER CATALOG NUMBER MOUNTING NO LAMP VOLTS DIMENSIONS REMARKS 4" RECESSED OPEN LED DOWNLIGHT, DIMMABLE, D2 IC RATED, SMOOTH WHITE TRIM CREE RC6 & LR6 & LT6WH RECESSED N/A 10.5W LED, 2700K 120 7.5" L X 12.5" W X 7.5" H ADD ALT TO TYPE D2: 4" RECESSED OPEN LED ADD ALTERNATE TO TYPE D2. D2A DOWNLIGHT, DIMMABLE, IC RATED, WHITE BAFFLE JUNO IC1LEDG3-27K-1 & 14W-WH RECESSED N/A 11W LED, 2700K 120 9-1/2" L X 6-3/4" W X 6" H EXISTING RECESSED INCANDESCENT FIXTURE TO REVIEW WITH ENGINEER IF D8 BE REUSED AS TAGGED ON PLAN - VERIFY EXISTING EXISTING RECESSED 1 EXISTING 120 EXISTING (E) FIXTURE IS NOT IC-RATED FIXTURE IS IC & AIRTIGHT PER IECC AND AIRTIGHT. COMPACT FLUORESCENT WALL SCONCE, WET FIXTURE IS EXISTING FROM E1 LOCATION, PROVIDED IN BASE BUILDING PHASE, N/A N/A WALL 1 26W CFL 120 N/A BASE BUILDING PHASE - SHOWN FOR REFERENCE ONLY CIRCUIT AS SHOWN ID1 SCONCE/VANITY LIGHT WITH HIGH EFFICACY LAMP BY OTHERS BY OTHERS WALL TBD SCREW-IN LED - TBD 120 TBD LUMINAIRE SCHEDULE - UNIT 310 NOTE: ALTERNATE EQUIVALENT LIGHTING PACKAGES ACCEPTED WITH ENGINEER'S REVIEW OF SUBMITTAL. FIXTURES MARKED "E" ARE EXISTING TO REMAIN IN PLACE. 04/29/14