HomeMy WebLinkAboutB16-0087_A5-02_1478903511.pdf8X16 CMU INTERIOR USE ONLY 6" VINYL BASEBOARD, TYPICAL 4" SLAB ON GRADE, POLISHED, TYPICAL W1-XX DIMENSIONSAL LUMBER, SEE PLAN FOR SIZE INTERIOR EXTERIOR CLOSED CELL BLOWN-IN INSULATION, R-21 MIN. BUILDING WRAP CEMENTITIOUS SIDING BLOCKING, PER STRUCTURAL 6 3/4" 2" END BRACKET NOTE: LADDER GAURD USED FOR FIRE FIGHTING TRAINING AND LADDER EXERCISES. IT IS A METAL BAR WHICH PROTECTS THE SIDING FROM LADDER IMPACTS. 1/4" MID-BRACKET LADDER GAURD FASTENERS PER STRUCTURAL END BRACKET MID-BRACKET LADDER GAURD OVERHANG TO PREVENT LATERAL LADDER SLIP END BRACKET BRACKET SIDE VIEW BRACKET ELEVATION VIEW 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 LOT 15 BIGHORN SUBDIVISION 4116 COLUMBINE DRIVE VAIL, CO 81657 A5.02 MISC. DETAILS VAIL FIRE STATION # 1 Project Number - 1547 04.29.2016 PERMIT SUBMITTAL 1 1/2" = 1'-0" 1 TYPICAL VINYL BASE @ CMU/CONCRETE FLOOR 3" = 1'-0" 2 LADDER GAURDS 3 LADDER GUARDS 3D 06/14/16