HomeMy WebLinkAboutB16-0087_E1.0_1478901749.pdfH/P HEAT/PHOTOELECTRIC SMOKE DETECTOR ELECTRICAL LEGEND (NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT) RECESSED OR SURFACE DOWNLIGHT WALL MOUNTED LIGHT FIXTURE RECESSED FLUOR. LIGHT FIXTURE SURFACE FLUOR. LIGHT FIXTURE Aa Aa FIXTURE DESIGNATIONS: UPPER CASE - FIXTURE TYPE LOWER CASE - SWITCH DESIGNATION SHADING ON FIXTURE INDICATES EMERG. BATTERY BACKUP FLUORESCENT STRIP FIXTURE TRACK LIGHT AS NOTED OR SCHEDULED WALL WASHER POLE-MOUNTED FIXTURE POST (BOLLARD) FIXTURE CEILING OR WALL MOUNTED EXIT LIGHT EMERGENCY BATTERY LIGHTS DUPLEX RECEPTACLE @ 18" UNLESS NOTED DOUBLE DUPLEX RECEPTACLE @ 18" UNLESS NOTED SPECIAL OUTLET AS NOTED FLUSH FLOOR DUPLEX RECEPTACLE DUPLEX RECEPTACLE HALF-SWITCHED @ 18" UNLESS NOTED TELE-POWER POLE JUNCTION BOX IN FLOOR, CEILING OR IN WALL MULTI-OUTLET PLUG STRIP COMPUTER/TELEPHONE OUTLET IN FLOOR OR WALL CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING TELEPHONE BACKBOARD CIRCUIT HOMERUN CONDUIT RUN BELOW FLOOR OR GRADE CONDUIT STUB-UP - CAP & MARK LIGHT SWITCH AT 46" UNLESS NOTED SUBSCRIPTS: 2 = 2-POLE SWITCH 3 = 3-WAY SWITCH 4 = 4-WAY SWITCH K = KEY-OPERATED SWITCH TO = THERMAL OVERLOAD SWITCH P = SWITCH WITH PILOT LIGHT DIMMER SWITCH W/ WATTAGE MAGNETIC MOTOR STARTER DISCONNECT SWITCH PANELBOARD OR LOAD CENTER, FLUSH OR SURFACE MOUNTED SWITCHBOARD, MOTOR CONTROL CENTER OR DISTRIBUTION BD TRANSFORMER GROUND PUSHBUTTON CONTROL STATION PHOTOELECTRIC CELL TIME SWITCH THERMOSTAT AT 60" UNLESS NOTED DIVISION 15 EQUIPMENT CIRCUIT BREAKER MOTOR OUTLET AUTOMATIC TRANSFER SWITCH FOOD SERVICE EQUIPMENT PC TS T ABBREVIATIONS - ABOVE COUNTER AC AFF - ABOVE FINISHED FLOOR - ABOVE FINISHED GRADE AFG - ALUMINUM AL - EMERGENCY EM - GROUND GND - GROUND FAULT INTERRUPTER GFI NIC - NOT IN CONTRACT NL - NIGHT LIGHT NTS - NOT TO SCALE UG - UNDERGROUND WP - WEATHER PROOF XFMR - TRANSFORMER +18" - MOUNTING HEIGHT TO CENTERLINE OF DEVICE AFF OR AFG FIRE ALARM SYSTEM FIRE ALARM CONTROL PANEL FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM PULL STATION ALARM HORN OR SPEAKER COMBINATION HORN/STROBE OR SPEAKER/STROBE THERMAL HEAT DETECTOR H SMOKE/IONIZATION DETECTOR I PHOTOELECTRIC SMOKE DETECTOR P DUCT DETECTOR SPRINKLER SYSTEM FLOW SWITCH SPRINKLER SYSTEM TAMPER SWITCH STROBE SMOKE/FIRE DAMPER CONNECTION REMOTE INDICATOR LIGHT COMMUNICATION SYSTEM SPEAKER IN CEILING OR WALL VOLUME CONTROL AT 60" UNLESS NOTED MICROPHONE OUTLET IN FLOOR BOX OR WALL CALL-IN SWITCH PROGRAM BELL INTERCOM CLOCK AMPLIFIER TELEVISION OUTLET CONTACT DOOR SWITCH IN JAMB OR HINGE SECURITY SYSTEM INTRUSION MOTION DETECTOR AS SPECIFIED, CORRIDOR/ROOM KEY-OPERATED ACCESS SWITCH SURVEILLANCE CAMERA DISTRIBUTION EQUIPMENT SYMBOLS DISCONNECT SWITCH FUSES CIRCUIT BREAKER CURRENT TRANSFORMER TRANSFORMER METER CU - COPPER STEP LIGHT FACP M = MOTION-OPERATED SWITCH POP-UP RECEPTACLE - ELECTRICAL CONTRACTOR EC - AUTHORITY HAVING JURISDICTION AHJ - MECHANICAL CONTRACTOR MC - PLUMBING CONTRACTOR PC UTP - UNSHIELDED TWISTED PAIR - GENERAL CONTRACTOR GC - REFERENCE REF THE ELECTRICAL CONTRACTOR WILL PROVIDE A WALK THROUGH WITH THE OWNER/ARCHITECT PRIOR TO FINAL ROUGH-IN AS FOLLOWS: x CONFIRM ALL LOCATIONS FOR LIGHT SWITCHES; ADD THREE WAYS IF FOUND NECESSARY. x REVIEW RECEPTACLE LOCATIONS; MOVE AS REQUIRED. PROVIDE UNIT PRICING IF ADDITIONAL RECEPTACLES ARE REQUIRED. x REVIEW RECEPTACLE LOCATIONS AT COUNTERS AND CONFIRM IF THOSE RECEPTACLES SHOULD BE ABOVE COUNTER OR BELOW. MOVE AS REQUIRED. PROVIDE WALK THROUGH WITH THE OWNER PRIOR TO ROUGH INTO CONFIRM ALL LOW VOLTAGE ROUGH IN AND RECEPTACLE LOCATIONS. IN GENERAL CONFIRM POWER AND LIGHTING REQUIREMENTS. THE ELECTRICIAN SHOULD BE PREPARED TO REWORK SOME DEVICE LOCATIONS. SIGNIFICANT REWORK SHOULD BE FLAGGED AND UNIT PRICING PROVIDED AND WRITTEN AUTHORIZATION FOR ADDITIONAL COSTS APPROVED PRIOR TO PROCEEDING. UNO - UNLESS NOTED OTHERWISE 14. All cabling shall be bundled and properly secured and terminated. The warranty period shall begin at the point of system acceptance system during this warranty period at no additional cost to the owner. free of defects of workmanship or products and will inspect and repair the from the date of project completion. The contractor warrants the system to be 15. The warranty set forth for this system shall consist of a full three (3) years or beneficial use, whichever comes later. Coordinate numbering scheme with owner. 13. No exposed wiring will be accepted unless approved in writing by the Engineer. Care must be taken to ensure cables are not kinked, bent beyond limit, including NEC, EIA/TIA 568,569 and 606, and federal, state and local codes. familiar and install in accordance with all applicable codes and standards, 12. All cable hangers shall be no more than 48" apart. Contractor shall be 11. Cable bends shall be no less than eight times the cable diameter or 1.00". termination. No more than .5 inches of exposed untwisted pairs shall be the extent in which each twisted pair is unraveled at the point of its physical 10. All connections of twisted wiring shall be made in such a way as to minimize length of the run. Splices and bridge taps with cabling are strictly prohibited. Cabling shall be free from tension at both ends, as well as through out the 9. All wiring shall be protected from moving mechanical or physical contacts. Bidder will identify any cable runs exceeding 90 meters 8. Route cables so as not to exceed 90 meters in length. In the case of "hard" drywall ceilings, adequate support shall be accomplished independent hangers. Cable "draped" across ceiling tiles is unacceptable. 7. All cable above the ceiling must be tied and properly supported with 6. Provide plenum rated cable when required by article NEC 300-22. overloaded, over-cinched, crushed, improperly untwisted, etc. present at these locations. Wiring is to be run in cable tray and conduit where specified. and provide solution to meet the 90 meter requirement. where reasonably possible. patch panel location, and each wall/floor faceplate that has wiring installed. 5. All cables will be labeled with self-laminating labels at each cable end, at each match faceplates to power, color coded for voice and data, match to cable modular RJ-45, 8 pin, 8 conductor, Hubbell, Leviton, or lucent or equivalent jacks, 3. The terminations at the station locations must be Category 6, T568B (AT&T) 2. Data cable will be colored blue. Voice cable will be colored white. manufacturers include: Berk-Tek, Belden, Lucent or equivalent. 500 Mhz or better category 6, 4 pair UTP as applicable. Acceptable 1. The cabling for voice and data must be continuous, home run, non-spliced, 4. Wall mounted patch panels will be provided. Outlets will be securely held in place. B. Cat 6 Wiring Requirements enclosed within cable trays, raceways or conduit, as specified. Cabling shall be in the wall, above the ceiling or where exposed, 1. WALL ASSEMBLY - THE 1, 2, 3 OR 4 HR FIRE-RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 HR FIRE RATED ASSEMBLIES) OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER SPACED 16 IN. (406 MM) OC WITH NOM 2 BY 4 IN. (51 BY 102 MM) LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. (92 MM) WIDE BY 1-3/8 IN. (35 MM) DEEP CHANNELS SPACED MAX 24 IN. (610 MM) OC. B. GYPSUM BOARD* - NOM 1/2 OR 5/8 IN. (13 OR 16 MM) THICK, 4 FT. (122 CM) WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RESISTANCE DIRECTORY. MAX DIAM OF OPENING IS 26 IN. (660 MM). 2. THROUGH PENETRANT - ONE CONDUIT INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM) (POINT CONTACT) TO MAX 2 IN. (51 MM). PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED: A. CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) STEEL CONDUIT OR NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING 3. FILL,VOID OR CAVITY MATERIAL* - CAULK OR SEALANT - MIN 5/8. 1-1/4,1-7/8 AND 2-1/2 IN. (16, 32, 48 AND 64 MM) THICKNESS OF CAULK FOR 1, 2, 3 AND 4 HR RATED ASSEMBLIES, RESPECTIVELY, APPLIED WITHIN ANNULUS, FLUSH WITH BOTH SURFACES OF WALL. MIN 1/4 IN. (6 MM) DIAM BEAD OF CAULK APPLIED TO GYPSUM BOARD/PENETRANT INTERFACE AT POINT CONTACT LOCATION ON BOTH SIDES OF WALL. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS SHOWN IN THE FOLLOWING TABLE. THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE OF THE PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, AS TABULATED TO THE LEFT. 3M COMPANY - CP 25WB+ CAULK OR FB-3000 WT SEALANT, *BEARING THE UL CLASSIFICATION MARKING PENETRATION THROUGH A FIRE-RATED WALL NOT TO SCALE equipment, etc. furnish by mechanical - refer to both electrical and electrical apparatus as shown on single line diagram and drawings. and mechanical drawing for scope and work and additional information. Complete connection of HVAC/Plumbing motor(s), water heater(s), Fire alarm system will be by electrical contractor. Complete provision, installation and connection of lighting fixtures, exit signs and lamps as specified and as shown on drawings. Complete branch circuit wiring required for the connection of emergency lighting and exit signs to existing emergency stand Complete feeder(s) installation as required for new and/or new control devices, etc. for a complete lighting and power system. including new panelboards, new conduits, new wires, new wiring devices, Complete wiring system for new lighting and power as shown, Electrical work shall include, but not limited to, these major items: indicated on drawing and as specified, as necessary to complete the contract. SCOPE: I. E. F. H. G. Provide grounding and bonding Facilities. Complete all electrical demolition as required. B. ELECTRICAL SPECIFICATIONS 1. by power system. D. C. A. Contractor shall submit shop drawings for engineer review and approval. MC cable permitted per local codes. Run hard pipe from panel to local Lighting fixtures. Shop drawing submittal shall include: Panelboard(s). CONDUIT AND WIRE: B. 5. A. B. b. a. and contractor shall have written approvals from building owner prior Core drilling and patching of existing building structure required for Operating, Maintenance and identification instructions manuals, if any. electrical work. Core drilling shall follow Building Standard procedures Applicable codes: National Electric Code (2014) PERMITS AND FEES: requirements of Federal, State or other City agencies having jurisdiction. Local Electrical Code, pertinent NFPA publications and to the Conform to the prevailing edition and amendments thereto of the SHOP DRAWINGS AND SUBMITTAL: to start of any work. Test of entire system and work. REGULATIONS AND CODES: 4. A. 2. J. 3. A. General Requirements 6. Finish per owner or architect. Convenience receptacles will be 15 A, decora style. Light switches will be 20 amp, commercial grade, decora style. B. ELECTRICAL DEVICES: A. Finish per owner or architect. Finish per owner or architect. Dimming switches will be a minimum of 600w or as noted, provide decora style. C. 7. All mounting heights will conform to ADA guidelines. D. Typical receptacle heights will be +18"AFF and switch heights will be +46"AFF unless noted otherwise. Provide GFI type receptacles at kitchens, bathrooms, garages, exterior etc. as required by code. E. junction box, and run MC cable from junction box to device. CONDUCTOR SIZES AND TYPES: For sizes #1/0 AWG and larger, use coppper THW or aluminum XHHW. For sizes #1 AWG and smaller, use only copper wire with 600V insulation, types TW, THHN, or THW - stranded in sizes #8 and larger, solid in sizes #10 and smaller. Control wiring shall be #14, stranded. Use type THHN for wires entering or passing through fluorescent lighting fixtures. All motors shall be wired with copper conductors only. Support all electrical equipment independent of accessible ceilings as required by NEC. SUPPORT: A. A. Obtain and pay for all necessary permits, inspections, examinations and fees or charges necessary for execution and completion of electrical work. A. Furnish all materials and labor required to execute this work as and contractor shall have written approvals from building owner prior Core drilling and patching of existing building structure required for electrical work. Core drilling shall follow Building Standard procedures K. L. Provide tamper proof receptacles at all residential areas as required by code. F. Test of entire system and work. +80"AFF P +80"AFF TELEPHONE ONE- LINE DIAGRAM TELEPHONE/ COMPUTER ROUGHIN #6 CU G ROUTE WIRE AT CEILING PARALLEL OR PERPENDICULAR TO STRUCTURE. SECURE TO STRUCTURE AT 4' INTERVALS OR LESS. STUB UP TO ABOVE ACCESSIBLE CEILNG STRUCTURED CABLE DISTRIBUTION PANEL 3/4"C DOUBLE GANG BOX W/ PULLWIRE AT 12" AFF UNO COLD WATER PIPE MAIN TELE/DATA ROOM NO SCALE T 12" (1'-0") 46" (3'-10") 48" (4'-0") 80" (6'-8") TYPICAL DEVICE MOUNTING HEIGHTS MAIN CIRCUIT BREAKER & BRANCH CIRCUIT BREAKERS MAXIMUM MOUNTING HEIGHT IS 79", MINIMUM IS 18". NOT TO SCALE NOTES: 1. HEIGHTS SHOWN ARE TYPICAL TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE. 2. DEVICES ABOVE DOORS SHALL BE CENTERED BETWEEN TOP OF DOOR TRIM AND CEILING LINE. 3. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS AND NOTED ON ELECTRICAL FLOOR PLANS SHALL GOVERN OVER THOSE SHOWN ABOVE. 4. FOR CEILING HEIGHTS HIGHER THAN 7'2", INSTALL FIRE ALARM NOTIFICATION AUDIO AND VISUAL APPLIANCES AT 80"AFF OTHERWISE INSTALL AT 6" BELOW CEILING. 5. MOUNTING HEIGHTS PER IBC 2009 AND ADA CODES FINISHED FLOOR TYPICAL 8'-0" CEILING 2"C PVC WITH PULLWIRE BURIED 20" BELOW GRADE CATV PEDESTAL COAX RECEPTACLE IN SINGLE GANG BOX @ 12" A.F.F. UNO QUANTITIES PER FLOOR PLANS (RG6 QUAD SHIELDED CABLE) 3/4"C CONDUIT STUBBED TO ACCESSIBLE CEILING, PLENUM RATED WIRE, WHEN REQUIRED, RAN TO BACK BOARD STRUCTURED CABLE DISTRIBUTION PANEL #6 CU G METALLIC COLDWATER PIPE NO SCALE (3) 2" C W/ PULLWIRE R3-37 R3-35 x 4/ 51* .')'0&  5%*'&7.'5 '   of Drawn By: Checked By: DATE: ISSUE: 02-22-16 DD SET AEC PROJECT #: TOV FIRE STATION #1 RENOVATION VAIL, COLORADO 81657 16001.00 www.aec-vail.com CMechanical, Electrical & Lighting Design Services Architectural Engineering Consultants Telephone: 970-748-8520 E G$Q 2IILFH ZLWK /(('Œ $FFUHGLWHG 3URIHVVLRQDOV 03-14-16 PROGRESS 03-22-16 PERMIT 04-01-16 CD SET 06/14/16