HomeMy WebLinkAboutB16-0087_E2.5_1465941540.pdfDN
D
E
C
5
6
4
1
3
2
A
8
F.1 F.2
F.3 F.4
7.5
4.9
7A
7B
7C
B
A1
7
3
4
B
B
C
C
C
C
C
C
C
C C
C
C
C C
C
C
A
C
C
C
C
C
C
A
A
A
C
A
A
A
D
D
D
G
G
G
G
G
G
G
G
K
L
P
C
3
C
3
C
S
R2-13
SHEET DETAIL NOTES:
GROUP THE SWITCHES FOR THE LIGHTS
WITH THE RECEPTACLE SWITCHES, TYPICAL.
1
1
1
1
R2-11
R1-15
UP TO
NEXT
LEVEL
DOWN
TO NEXT
LEVEL
DOWN
TO NEXT
LEVEL
P
PANEL
R1
STANDARD
LIGHTS
RED
LIGHTS
B1 & B2
PANELS
STANDARD
LIGHTS
LIGHTING CONTACTOR: SQUARE D
MODEL 8903LO60-V02-A12 WITH
HOLDING CIRCUIT INTERLOCK AND
9991 ENCLOSURE, NORMALLY OPEN.
THIS CONTACTOR HAS A TOTAL OF 2
POLES.
LIGHTING CONTACTOR: SQUARE D MODEL
8903LO1200-V02-A12 WITH HOLDING
CIRCUIT INTERLOCK AND 9991 ENCLOSURE,
CONVERT TO NORMALLY-CLOSED.WHEN
CONVERTING THE CONTACTOR TO
NORMALLY CLOSED THERE ARE A TOTAL
OF 4 POLES AVAILABLE.
CONNECT THE FOLLOWING CIRCUITS
FROM PANELS R2 TO THE POLES OF
THE LIGHTING CONTACTOR:
R2-11
R2-13
2 POLE SHALL BE SPARE
CONNECT THE FOLLOWING CIRCUITS
FROM PANEL B & B2 TO THE POLES OF
THE LIGHTING CONTACTOR:
B2-13
1 POLES SHALL BE SPARE
PROVIDE PUSH BUTTONS TO ENGAGE RED-LIGHT
SYSTEM (SEE PLANS FOR QUANTITY AND LOCATION).
PROVIDE SQUARE D MODEL 9001KXRB1 PUSH
BUTTONS WITH LABELS TO OPERATE CONTACTORS.
PROVIDE LOW VOLTAGE TRANSFORMER ON PANEL
EM FOR THE PUSH BUTTON POWER.
LIGHTING CONTACTOR: SQUARE D MODEL
8903LO1200-V02-A12 WITH HOLDING
CIRCUIT INTERLOCK AND 9991 ENCLOSURE,
CONVERT TO NORMALLY-CLOSED.WHEN
CONVERTING THE CONTACTOR TO
NORMALLY CLOSED THERE ARE A TOTAL
OF 4 POLES AVAILABLE.
PROVIDE PUSH BUTTONS TO DIS-ENGAGE RED-LIGHT
SYSTEM (SEE PLANS FOR QUANTITY AND LOCATION).
PROVIDE SQUARE D MODEL 9001KXRB1 PUSH BUTTON
WITH LABEL TO OPERATE CONTACTORS. PROVIDE LOW
VOLTAGE TRANSFORMER ON PANEL EM FOR THE PUSH
BUTTON POWER.
WHAT IS SHOWN ABOVE IS DIAGRAMMATICAL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO
PROVIDE ALL EQUIPMENT NECESSARY TO OPERATE THE SYSTEM. COORDINATE EQUIPMENT
REQUIREMENTS WITH MANUFACTURER PRIOR TO ROUGH-IN, VERIFY EQUIPMENT COMPATIBILITY WITH
THE MANUFACTURER IN ORDER TO PROVIDE A FULLY OPERATIONAL SYSTEM AS REQUIRED BY THE
OWNERS.
CONNECT THE FOLLOWING CIRCUITS
FROM PANEL B & B2 TO THE POLES OF
THE LIGHTING CONTACTOR:
B2 - 1
B2 - 3
B2 - 5
B2 - 7
B2 - 9,11
2 POLES SHALL BE SPARE LIGHTING CONTACTOR: SQUARE D MODEL
8903LO60-V02-A12 WITH HOLDING CIRCUIT
INTERLOCK AND 9991 ENCLOSURE,
CONVERT TO NORMALLY-CLOSED. THIS
CONTACTOR HAS A TOTAL OF 8 POLES.
REDLIGHT
CIRCUITS
STANDARD
LIGHT
CIRCUITS
PANEL
R2
CONNECT THE FOLLOWING CIRCUITS
FROM PANELS R1 TO THE POLES OF
THE LIGHTING CONTACTOR:
R1-13
R1-15
2 POLE SHALL BE SPARE
CONNECT THE FOLLOWING CIRCUITS
FROM PANELS R3 TO THE POLES OF
THE LIGHTING CONTACTOR:
R3-12
R3-41
R3-29
1 POLE SHALL BE SPARE
PANEL
R3
LIGHTING CONTACTOR: SQUARE D
MODEL 8903LO60-V02-A12 WITH
HOLDING CIRCUIT INTERLOCK AND
9991 ENCLOSURE, NORMALLY OPEN.
THIS CONTACTOR HAS A TOTAL OF 2
POLES.
LIGHTING CONTACTOR: SQUARE D MODEL
8903LO60-V02-A12 WITH HOLDING CIRCUIT
INTERLOCK AND 9991 ENCLOSURE,
CONVERT TO NORMALLY-CLOSED. THIS
CONTACTOR HAS A TOTAL OF 4 POLES.
REDLIGHT
CIRCUITS
STANDARD
LIGHT
CIRCUITS
CONNECT THE FOLLOWING CIRCUITS
FROM PANELS R3 TO THE POLES OF
THE LIGHTING CONTACTOR:
R3-14
1 POLE SHALL BE SPARE
STANDARD
LIGHT
CIRCUITS
STANDARD
LIGHT
CIRCUITS
STANDARD
LIGHTS
STANDARD
LIGHTS
RED
LIGHTS
RED LIGHT SYSTEM SEQUENCE
OF OPERATIONS:
ALL LIGHTING CONTACTORS THAT ARE CONNECTED TO STANDARD
LIGHTS SHALL BE NORMALLY CLOSED, AND SHALL OPEN WHEN 10V
SIGNAL FROM A PUSH BUTTON IS DETECTED.
ALL LIGHTING CONTACTORS THAT ARE CONNECTED TO THE RED
LIGHTS SHALL BE NORMALLY OPEN, AND SHALL CLOSE WHEN 10V
SIGNAL FROM A PUSH BUTTON IS DETECTED.
A SEPARATE PUSH BUTTON WILL BE PROVIDED TO DIS-ENGAGE
THE RED LIGHT SYSTEM. WHEN THIS BUTTON IS PRESSED THE
CONTACTORS CONNECTED TO THE RED LIGHTS WILL OPEN, AND
THE CONTACTORS CONNECTED TO THE STANDARD LIGHTS SHALL
CLOSE.
ALL PUSH BUTTONS AND CONTACTORS SHALL BE LABELED TO
ENSURE THAT THE SYSTEM IS OPERATED PROPERLY.
4/ 51*
.'8'. 691
.+)*6+0)
2.#0
5%#.' Ä
'
of
Drawn By: Checked By:
DATE: ISSUE:
02-22-16 DD SET
AEC PROJECT #: TOV FIRE STATION #1
RENOVATION
VAIL, COLORADO 81657
16001.00
www.aec-vail.com
CMechanical, Electrical & Lighting Design Services
Architectural Engineering Consultants
Telephone:
970-748-8520
E
G$Q 2IILFH ZLWK /((' $FFUHGLWHG 3URIHVVLRQDOV
03-14-16
PROGRESS
03-22-16
PERMIT
04-01-16
CD SET
NORTH
LEVEL TWO LIGHTING PLAN
SCALE: 3/16" = 1'-0"
06/14/16