Loading...
HomeMy WebLinkAboutB16-0087_E2.5_1478901762.pdfDN D E C 5 6 4 1 3 2 A 8 F.1 F.2 F.3 F.4 7.5 4.9 7A 7B 7C B A1 7 3 4 B B C C C C C C C C C C C C C C C A C C C C C C A A A C A A A D D D G G G G G G G G K L P C 3 C 3 C S R2-13 SHEET DETAIL NOTES: GROUP THE SWITCHES FOR THE LIGHTS WITH THE RECEPTACLE SWITCHES, TYPICAL. 1 1 1 1 R2-11 R1-15 UP TO NEXT LEVEL DOWN TO NEXT LEVEL DOWN TO NEXT LEVEL P PANEL R1 STANDARD LIGHTS RED LIGHTS B1 & B2 PANELS STANDARD LIGHTS LIGHTING CONTACTOR: SQUARE D MODEL 8903LO60-V02-A12 WITH HOLDING CIRCUIT INTERLOCK AND 9991 ENCLOSURE, NORMALLY OPEN. THIS CONTACTOR HAS A TOTAL OF 2 POLES. LIGHTING CONTACTOR: SQUARE D MODEL 8903LO1200-V02-A12 WITH HOLDING CIRCUIT INTERLOCK AND 9991 ENCLOSURE, CONVERT TO NORMALLY-CLOSED.WHEN CONVERTING THE CONTACTOR TO NORMALLY CLOSED THERE ARE A TOTAL OF 4 POLES AVAILABLE. CONNECT THE FOLLOWING CIRCUITS FROM PANELS R2 TO THE POLES OF THE LIGHTING CONTACTOR: R2-11 R2-13 2 POLE SHALL BE SPARE CONNECT THE FOLLOWING CIRCUITS FROM PANEL B & B2 TO THE POLES OF THE LIGHTING CONTACTOR: B2-13 1 POLES SHALL BE SPARE PROVIDE PUSH BUTTONS TO ENGAGE RED-LIGHT SYSTEM (SEE PLANS FOR QUANTITY AND LOCATION). PROVIDE SQUARE D MODEL 9001KXRB1 PUSH BUTTONS WITH LABELS TO OPERATE CONTACTORS. PROVIDE LOW VOLTAGE TRANSFORMER ON PANEL EM FOR THE PUSH BUTTON POWER. LIGHTING CONTACTOR: SQUARE D MODEL 8903LO1200-V02-A12 WITH HOLDING CIRCUIT INTERLOCK AND 9991 ENCLOSURE, CONVERT TO NORMALLY-CLOSED.WHEN CONVERTING THE CONTACTOR TO NORMALLY CLOSED THERE ARE A TOTAL OF 4 POLES AVAILABLE. PROVIDE PUSH BUTTONS TO DIS-ENGAGE RED-LIGHT SYSTEM (SEE PLANS FOR QUANTITY AND LOCATION). PROVIDE SQUARE D MODEL 9001KXRB1 PUSH BUTTON WITH LABEL TO OPERATE CONTACTORS. PROVIDE LOW VOLTAGE TRANSFORMER ON PANEL EM FOR THE PUSH BUTTON POWER. WHAT IS SHOWN ABOVE IS DIAGRAMMATICAL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE ALL EQUIPMENT NECESSARY TO OPERATE THE SYSTEM. COORDINATE EQUIPMENT REQUIREMENTS WITH MANUFACTURER PRIOR TO ROUGH-IN, VERIFY EQUIPMENT COMPATIBILITY WITH THE MANUFACTURER IN ORDER TO PROVIDE A FULLY OPERATIONAL SYSTEM AS REQUIRED BY THE OWNERS. CONNECT THE FOLLOWING CIRCUITS FROM PANEL B & B2 TO THE POLES OF THE LIGHTING CONTACTOR: B2 - 1 B2 - 3 B2 - 5 B2 - 7 B2 - 9,11 2 POLES SHALL BE SPARE LIGHTING CONTACTOR: SQUARE D MODEL 8903LO60-V02-A12 WITH HOLDING CIRCUIT INTERLOCK AND 9991 ENCLOSURE, CONVERT TO NORMALLY-CLOSED. THIS CONTACTOR HAS A TOTAL OF 8 POLES. REDLIGHT CIRCUITS STANDARD LIGHT CIRCUITS PANEL R2 CONNECT THE FOLLOWING CIRCUITS FROM PANELS R1 TO THE POLES OF THE LIGHTING CONTACTOR: R1-13 R1-15 2 POLE SHALL BE SPARE CONNECT THE FOLLOWING CIRCUITS FROM PANELS R3 TO THE POLES OF THE LIGHTING CONTACTOR: R3-12 R3-41 R3-29 1 POLE SHALL BE SPARE PANEL R3 LIGHTING CONTACTOR: SQUARE D MODEL 8903LO60-V02-A12 WITH HOLDING CIRCUIT INTERLOCK AND 9991 ENCLOSURE, NORMALLY OPEN. THIS CONTACTOR HAS A TOTAL OF 2 POLES. LIGHTING CONTACTOR: SQUARE D MODEL 8903LO60-V02-A12 WITH HOLDING CIRCUIT INTERLOCK AND 9991 ENCLOSURE, CONVERT TO NORMALLY-CLOSED. THIS CONTACTOR HAS A TOTAL OF 4 POLES. REDLIGHT CIRCUITS STANDARD LIGHT CIRCUITS CONNECT THE FOLLOWING CIRCUITS FROM PANELS R3 TO THE POLES OF THE LIGHTING CONTACTOR: R3-14 1 POLE SHALL BE SPARE STANDARD LIGHT CIRCUITS STANDARD LIGHT CIRCUITS STANDARD LIGHTS STANDARD LIGHTS RED LIGHTS RED LIGHT SYSTEM SEQUENCE OF OPERATIONS: ALL LIGHTING CONTACTORS THAT ARE CONNECTED TO STANDARD LIGHTS SHALL BE NORMALLY CLOSED, AND SHALL OPEN WHEN 10V SIGNAL FROM A PUSH BUTTON IS DETECTED. ALL LIGHTING CONTACTORS THAT ARE CONNECTED TO THE RED LIGHTS SHALL BE NORMALLY OPEN, AND SHALL CLOSE WHEN 10V SIGNAL FROM A PUSH BUTTON IS DETECTED. A SEPARATE PUSH BUTTON WILL BE PROVIDED TO DIS-ENGAGE THE RED LIGHT SYSTEM. WHEN THIS BUTTON IS PRESSED THE CONTACTORS CONNECTED TO THE RED LIGHTS WILL OPEN, AND THE CONTACTORS CONNECTED TO THE STANDARD LIGHTS SHALL CLOSE. ALL PUSH BUTTONS AND CONTACTORS SHALL BE LABELED TO ENSURE THAT THE SYSTEM IS OPERATED PROPERLY. 4/ 51* .'8'. 691 .+)*6+0) 2.#0 5%#.'   žÄ '   of Drawn By: Checked By: DATE: ISSUE: 02-22-16 DD SET AEC PROJECT #: TOV FIRE STATION #1 RENOVATION VAIL, COLORADO 81657 16001.00 www.aec-vail.com CMechanical, Electrical & Lighting Design Services Architectural Engineering Consultants Telephone: 970-748-8520 E G$Q 2IILFH ZLWK /(('Œ $FFUHGLWHG 3URIHVVLRQDOV 03-14-16 PROGRESS 03-22-16 PERMIT 04-01-16 CD SET NORTH LEVEL TWO LIGHTING PLAN SCALE: 3/16" = 1'-0" 06/14/16