Loading...
HomeMy WebLinkAboutB16-0087_M3.0_1465941600.pdfMECH ROOM BUNKER GEAR 1ST FLR HALLWAY STAIRS PUBLIC RESTROOM UP WDD E C 5 6 4 1 3 2 7 A B 8 F.1 F.2 F.3 F.4 7.5 A1 4.9 7A 7B 7C UP GYM CONFERENCE ROOM OFFICE A OFFICE B OFFICE HALLWAY ENTRY APPARATUS BAY CLEAN ROOM STORAGE HALLWAY STORAGE ROOM 2 STORAGE ROOM 1 EPO HRV 1 EMG-1 L 3 12400-OA 60x66 L 4 12400-EX 60x66 M M 12x8 [15x11] L 5 310-OA 24x12 L 6 310-EX 24x12 12x8 12x8 HC 2 12x8 [14x10]  ‘  ‘  ‘  ‘ A 60-S 24x6 A 50-S 24x6  ‘  ‘ ‘ ‘ ‘  ‘  ‘  ‘ 12x8 12x8 [14x10] SHEET DETAIL NOTES: INSTALL HRV-3 ,1 +25,=217$/ 326,7,21 ƒ 527$7(' 9(5,)< :,7+ MANUFACTURER PRIOR TO ORDERING. INSTALL BDD ON EXHAUST AND M.O.D. ON INTAKE DUCTWORK (NOT SHOWN). COORDINATE ACCESS PANEL (MIN. 36x48 OR EQUIVALENT) WITH ARCHITECT AND G.C. IN FIELD. INSTALL HC-2, INTERLOCK 2-WAY MODULATING VALVE WITH THE DUCT MOUNTED SENSOR (IN THE HRV-2 DISCHARGE DUCT). VERIFY COIL DIMENSIONS AND SPACE REQUIREMENTS IN FIELD PRIOR TO COIL PURCHASE. ADJUST SIZE AND CONNECTION SIDE PER FIELD MEASUREMENTS. CONTACT ENGINEER FOR ASSISTANCE IF REQUIRED. VERIFY STATE AND ADEQUACY OF THE EXISTING EF-1. IF ACCEPTABLE REUSE AND RELOCATE TO THIS LOCATION IN THE HALLWAY VOID SPACE. G.C. TO PROVIDE ACCESS PANEL (MIN. 36x36 OR EQUIVALENT) FOR SERVICE AND MAINTENANCE. IF THE FAN CANNOT BE REUSED, REPLACE WITH THE NEW ONE. DELETED. DELETED. VERIFY STATE AND ADEQUACY OF THE EXISTING RADIANT HEATERS AND CAPACITY FOR REUSING WITH RELOCATED EXHAUST AS INDICATED ON THE PLANS PRIOR TO ANY WORK. IF THE EXISTING SYSTEM CANNOT BE REUSED AS IS, REPLACE BURNERS WITH CORAYVAC CRV-B-2 (VERIFY SIZES PRIOR TO PURCHASING) AND A NEW VACUUM PUMP CORAYVAC EP100, INSTALL CONDENSATE TEE ON THE BOTTOM OF THE VERTICAL VENT AND ROUTE DRAIN INTO THE NEAREST FLOOR DRAIN. TERMINATE VIA AIR GAP. COORDINATE DRAIN INSTALLATION WITH THE RADIANT HEATERS MANUFACTURER. PORCELAIN COATED RADIANT TUBING. DEMO EXISTING RADIANT AND PLYMOVENT DUCT AND EQUIPMENT. RELOCATE INTO THE NEW LOCATIONS (OR PROVIDE NEW EQUIPMENT IF EXISTING CANNOT BE REUSED). PLYMOVENT DUCT UP TO THE (E) EF-1. EXISTING PLYMOVENT TO REMAIN. TERMINATE DRYER VENT THRU THE WALL, 10' FROM PROPERTY LINE, 10' FROM ANY MECHANICAL AIR INTAKE OR 3' ABOVE IT, 3' FROM NATURAL AIR INTAKE, AND 5' ABOVE GRADE. TERMINATE LOUVERS MIN. 5' ABOVE GRADE, 10' FROM THE PROPERTY LINE, EXHAUST 10' FROM ANY MECHANICAL AIR INTAKE OR 3' ABOVE IT, AND 3' FROM NATURAL AIR INTAKE INTO THE BUILDING. TERMINATE LOUVERS MIN. 3' ABOVE GRADE (OR AS AVAILABLE IF SNOWMELT IS PROVIDED), 10' FROM THE PROPERTY LINE, EXHAUST 10' FROM ANY MECHANICAL AIR INTAKE OR 3' ABOVE IT, AND 3' FROM NATURAL AIR INTAKE INTO THE BUILDING. TERMINATE BOILER INTAKE & EXHAUST MIN. 3' ABOVE GRADE, 10' FROM THE PROPERTY LINE, EXHAUST 10' FROM ANY MECHANICAL AIR INTAKE OR 3' ABOVE IT, AND 12" FROM NATURAL AIR INTAKE INTO THE BUILDING. BOILER FLUE MUST UTILIZE CPVC OR PP. PVC IS NOT ALLOWED. EXISTING T-STAT FOR RADIANT HEATERS TO BE REUSED. IF THE SYSTEM IS REPLACED AND NEW T-STAT IS NEEDED REPLACE WITH NEW T-STAT. COORDINATE IN FIELD WITH THE EQUIPMENT MANUFACTURER. 7(50,1$7(  ‘ (;+$867 0,1  $:$< )520 3523(57< /,1(  FROM MECHANICAL AIR INTAKE, 3' FROM ANY NATURAL AIR INTAKE AND 5' ABOVE GROUND. ELECTRICAL CONTRACTOR TO PROVIDE 120 V POWER FOR MOTORIZED DAMPERS IN THIS LOCATION. INTERLOCK WITH THE GENERATOR. ALLOW GENERATOR TO OPERATE AFTER DAMPERS ARE FULLY OPEN (MECHANICAL CONTRACTOR TO PROVIDE DAMPER POSITION SWITCHES TO INDICATE THE POSITION TO THE GENERATOR, COORDINATE WITH THE ELECTRICAL CONTRACTOR). ELECTRICAL CONTRACTOR TO PROVIDE HEAT MATS (SNOWMELT) MIN. 3' IN FRONT OF THE LOUVERS TO ALLOW LOWERED HEIGHT ABOVE GRADE INSTALLATION. 5287(  ‘ 0$.(83 $,5 '8&7 83 7+58 7+( 522) 7(50,1$7( :,7+ $ GOOSENECK, MIN. 36" ABOVE THE ROOF, 10' FROM PROPERTY LINE. PROVIDE MOTORIZED DAMPER AND INTERLOCK WITH EF-2. 1 2 GENERAL NOTES: 1. ALL DUCTWORK DIMENSIONS ARE SHOWN INSIDE TO INSIDE. DIMENSIONS IN [ ] INDICATE OUTER SIZES WITH INSULATION. THESE SIZES MAY DIFFER BASED ON THE SELECTED INSULATION. VERIFY IN FIELD PRIOR TO INSTALLATION. 2. ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1" LINER UNLESS OTHERWISE NOTED. ALL OUTSIDE AIR INTAKE AND ROUND DUCTWORK SHALL BE WRAPPED WITH 1.5" THICK INSULATION UNLESS OTHERWISE NOTED. 3. ALL FINAL DUCTWORK CONNECTIONS TO SUPPLY GRILLES (OR PLENUMS) SHALL BE COMPLETED WITH ACOUSTICAL FLEXIBLE DUCT UNLESS OTHERWISE NOTED AND A MAXIMUM LENGTH OF FIVE FEET. 4. ALL ROUND DUCT CONNECTIONS TO ROUND DUCTWORK SHALL BE CONICAL TEES. 5. ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES. 6. ALL DUCTWORK SHALL BE RUN TIGHT TO UNDERSIDE OF STRUCTURE WHERE IT EXISTS UNLESS OTHERWISE NOTED. 7. ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY. 8. ALL SUPPLY GRILLES SHALL HAVE INCLUDE A BALANCING DAMPER UNLESS OTHERWISE NOTED (EVEN THOUGH THEY MAY NOT BE SHOWN EVERYWHERE). IF THE DAMPER IS LOCATED IN AN INACCESSIBLE LOCATION, CABLE-STYLE DAMPERS (ROTOTWIST OR EQUIVALENT) SHALL BE INSTALLED AND SHALL BE ADJUSTABLE FROM THE GRILLE FACE. MULTIPLE RETURN DIFFUSERS IF SERVED BY A COMMON RETURN DUCTWORK SHALL BE EQUIPPED WITH BALANCING DAMPERS. 9. COORDINATE ALL ACCESS PANEL LOCATIONS WITH THE ARCHITECT. 3 4 5 B 50-EX 10x10 B 70-EX 10x10 B-2 B-1 GF-1 WH-1 HX-1 GF-2  ‘ ‘  ‘ ‘  ‘ A 50-S 24x6 A 50-S 24x6 A 50-S 24x6 B 50-EX 10x10 6 6 6 6 6 6 6 RELOCATED OR NEW VACUUM PUMP 7 7 7 7 8 8 DRAIN TEE RE: NOTE #6 9 9 9 10 10 11 11 11 12 12 12 T T T T T T T T T T H PB PB PB 13 13 13 B 100-EX 10x10  ‘  ‘ A 50-S 10x10 B 50-EX 10x10  ‘ TO BB-14, 15 TO BB-13 TO BB-6 TO HRV-1 TO BB-10 TO LIGHTS & HRV-1 TO BB-1 - 5 T TO BB-6 - 12 T 14 14 TO HRV-1 T TO BB-23,24 TO EF-2 TO BB-21,22 TO HRV-1 TO BB-16 - 20 TO BB-25 - 26 TO HRV-1 EF 2  ‘ 15 15 M 16 16 16 17 17 17 BDD M 18 18 1 2 3 of Drawn By: Checked By: DATE: ISSUE: 02-22-16 DD SET AEC PROJECT #: TOV FIRE STATION #1 RENOVATION VAIL, COLORADO 81657 16001.00 www.aec-vail.com CMechanical, Electrical & Lighting Design Services Architectural Engineering Consultants Telephone: 970-748-8520 E G$Q 2IILFH ZLWK /(('Œ $FFUHGLWHG 3URIHVVLRQDOV 03-14-16 PROGRESS 03-22-16 PERMIT 04-01-16 CD SET /< 61% .'8'.  *8#% 2.#0 5%#.'   žÄ /   NORTH LEVEL 1 HVAC PLAN SCALE: 3/16" = 1'0" 06/14/16