Loading...
HomeMy WebLinkAboutB16-0087_M3.1_1465941600.pdfDN D E C 5 6 4 1 3 2 7 A B 8 F.1 F.2 F.3 F.4 7.5 A1 4.9 7A 7B 7C EHU #2 STORAGE EHU #2 BED - BATH EHU #2 BED EHU #2 LIVING EHU CORRIDOR EHU #1 BED EHU #1 BED - BATH EHU #1 LIVING EHU #1 KITCHEN 2ND FLR HALLWAY / STAIRS VOID SPACE (E) EF-1 SILENCER  ‘ '1  ‘ 83  ‘ 83  '1 L 8 300-EX 18x12  ‘  ‘ A 50-S 14x6 10x8 10x8 [12x10] 10x8  ‘ A 250-S 14x6 B 200-EX 14x6 B 100-EX 10x10 10x8 [13x11] HRV 2 HC 3 L 9 300-EX 18x12  ‘ A 50-S 14x6  ‘ B 100-EX 10x10  ‘ 83  ‘ 83 VD SHEET DETAIL NOTES: INSTALL HRV-2 ,1 +25,=217$/ 326,7,21 ƒ 527$7(' 9(5,)< :,7+ MANUFACTURER PRIOR TO ORDERING. INSTALL BDD ON EXHAUST AND MOTORIZED DAMPER ON O.A. INTAKE DUCTWORK. COORDINATE ACCESS PANEL (MIN. 36x48 OR EQUIVALENT) WITH ARCHITECT AND G.C. IN FIELD. INSTALL HC-3, INTERLOCK 2-WAY MODULATING VALVE WITH THE DUCT MOUNTED SENSOR (IN THE HRV-2 DISCHARGE DUCT). VERIFY COIL DIMENSIONS AND SPACE REQUIREMENTS IN FIELD PRIOR TO COIL PURCHASE. ADJUST SIZE AND CONNECTION SIDE PER FIELD MEASUREMENTS. CONTACT ENGINEER FOR ASSISTANCE IF REQUIRED. VERIFY STATE AND ADEQUACY OF THE EXISTING EF-1. IF ACCEPTABLE REUSE AND RELOCATE TO THIS LOCATION IN THE HALLWAY VOID SPACE. G.C. TO PROVIDE ACCESS PANEL (MIN. 36x36 OR EQUIVALENT) FOR SERVICE AND MAINTENANCE. IF THE FAN CANNOT BE REUSED, REPLACE WITH THE NEW ONE. PROVIDE NEW SILENCER IF REQUIRED, VERIFY WITH THE MANUFACTURER, OTHERWISE OMIT. G.C. TO PROVIDE SHAFT FOR THE EXHAUSTS. MAINTAIN MIN. 1" CLEARANCE (OR AS PER MANUFACTURER) TO COMBUSTIBLES. COORDINATE IN FIELD PRIOR TO INSTALLATION. VERIFY VENTS SIZES WITH MANUFACTURER PRIOR TO INSTALLATION. 1 2 GENERAL NOTES: 1. ALL DUCTWORK DIMENSIONS ARE SHOWN INSIDE TO INSIDE. DIMENSIONS IN [ ] INDICATE OUTER SIZES WITH INSULATION. THESE SIZES MAY DIFFER BASED ON THE SELECTED INSULATION. VERIFY IN FIELD PRIOR TO INSTALLATION. 2. ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1" LINER UNLESS OTHERWISE NOTED. ALL OUTSIDE AIR INTAKE AND ROUND DUCTWORK SHALL BE WRAPPED WITH 1.5" THICK INSULATION UNLESS OTHERWISE NOTED. 3. ALL FINAL DUCTWORK CONNECTIONS TO SUPPLY GRILLES (OR PLENUMS) SHALL BE COMPLETED WITH ACOUSTICAL FLEXIBLE DUCT UNLESS OTHERWISE NOTED AND A MAXIMUM LENGTH OF FIVE FEET. 4. ALL ROUND DUCT CONNECTIONS TO ROUND DUCTWORK SHALL BE CONICAL TEES. 5. ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES. 6. ALL DUCTWORK SHALL BE RUN TIGHT TO UNDERSIDE OF STRUCTURE WHERE IT EXISTS UNLESS OTHERWISE NOTED. 7. ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY. 8. ALL SUPPLY GRILLES SHALL HAVE INCLUDE A BALANCING DAMPER UNLESS OTHERWISE NOTED (EVEN THOUGH THEY MAY NOT BE SHOWN EVERYWHERE). IF THE DAMPER IS LOCATED IN AN INACCESSIBLE LOCATION, CABLE-STYLE DAMPERS (ROTOTWIST OR EQUIVALENT) SHALL BE INSTALLED AND SHALL BE ADJUSTABLE FROM THE GRILLE FACE. MULTIPLE RETURN DIFFUSERS IF SERVED BY A COMMON RETURN DUCTWORK SHALL BE EQUIPPED WITH BALANCING DAMPERS. 9. COORDINATE ALL ACCESS PANEL LOCATIONS WITH THE ARCHITECT. 1 2 3 3 4 4 5 5 T T T T T TO BB-27 - 34 TO BB-35 - 37 H TO HRV-3 TO LIGHTS & HRV-4 H TO HRV-4 TO BB-38 TO BB-39 - 41 H TO HRV-2 H TO HRV-2 TO BB-42- 44 TO LIGHTS & HRV-2 M BDD of Drawn By: Checked By: DATE: ISSUE: 02-22-16 DD SET AEC PROJECT #: TOV FIRE STATION #1 RENOVATION VAIL, COLORADO 81657 16001.00 www.aec-vail.com CMechanical, Electrical & Lighting Design Services Architectural Engineering Consultants Telephone: 970-748-8520 E G$Q 2IILFH ZLWK /(('Œ $FFUHGLWHG 3URIHVVLRQDOV 03-14-16 PROGRESS 03-22-16 PERMIT 04-01-16 CD SET /< 61% .'8'.  *8#% 2.#0 5%#.'   žÄ /   NORTH LEVEL 2 HVAC PLAN SCALE: 3/16" = 1'0" 06/14/16