F.1 F.2
F.3 F.4
7.5
A1
4.9
7A
7B
7C
EHU #2 STORAGE
EHU #2 BED - BATH
EHU #2 BED
EHU #2 LIVING
EHU CORRIDOR
EHU #1 BED
EHU #1 BED - BATH
EHU #1 LIVING
EHU #1 KITCHEN
2ND FLR HALLWAY /
STAIRS
VOID SPACE
(E) EF-1
SILENCER
'1
83
83 '1
L
8
300-EX
18x12
A
50-S
14x6
10x8
10x8 [12x10]
10x8
A
250-S
14x6
B
200-EX
14x6
B
100-EX
10x10
10x8 [13x11]
HRV
2
HC
3
L
9
300-EX
18x12
A
50-S
14x6
B 100-EX
10x10
83
83
VD
SHEET DETAIL NOTES:
INSTALL HRV-2 ,1 +25,=217$/ 326,7,21 527$7(' 9(5,)< :,7+
MANUFACTURER PRIOR TO ORDERING. INSTALL BDD ON EXHAUST AND
MOTORIZED DAMPER ON O.A. INTAKE DUCTWORK. COORDINATE
ACCESS PANEL (MIN. 36x48 OR EQUIVALENT) WITH ARCHITECT AND G.C.
IN FIELD.
INSTALL HC-3, INTERLOCK 2-WAY MODULATING VALVE WITH THE DUCT
MOUNTED SENSOR (IN THE HRV-2 DISCHARGE DUCT). VERIFY COIL
DIMENSIONS AND SPACE REQUIREMENTS IN FIELD PRIOR TO COIL
PURCHASE. ADJUST SIZE AND CONNECTION SIDE PER FIELD
MEASUREMENTS. CONTACT ENGINEER FOR ASSISTANCE IF REQUIRED.
VERIFY STATE AND ADEQUACY OF THE EXISTING EF-1. IF ACCEPTABLE
REUSE AND RELOCATE TO THIS LOCATION IN THE HALLWAY VOID
SPACE. G.C. TO PROVIDE ACCESS PANEL (MIN. 36x36 OR EQUIVALENT)
FOR SERVICE AND MAINTENANCE. IF THE FAN CANNOT BE REUSED,
REPLACE WITH THE NEW ONE.
PROVIDE NEW SILENCER IF REQUIRED, VERIFY WITH THE
MANUFACTURER, OTHERWISE OMIT.
G.C. TO PROVIDE SHAFT FOR THE EXHAUSTS. MAINTAIN MIN. 1"
CLEARANCE (OR AS PER MANUFACTURER) TO COMBUSTIBLES.
COORDINATE IN FIELD PRIOR TO INSTALLATION. VERIFY VENTS SIZES
WITH MANUFACTURER PRIOR TO INSTALLATION.
1
2
GENERAL NOTES:
1. ALL DUCTWORK DIMENSIONS ARE SHOWN INSIDE TO INSIDE. DIMENSIONS
IN [ ] INDICATE OUTER SIZES WITH INSULATION. THESE SIZES MAY
DIFFER BASED ON THE SELECTED INSULATION. VERIFY IN FIELD PRIOR
TO INSTALLATION.
2. ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1" LINER
UNLESS OTHERWISE NOTED. ALL OUTSIDE AIR INTAKE AND ROUND
DUCTWORK SHALL BE WRAPPED WITH 1.5" THICK INSULATION UNLESS
OTHERWISE NOTED.
3. ALL FINAL DUCTWORK CONNECTIONS TO SUPPLY GRILLES (OR PLENUMS)
SHALL BE COMPLETED WITH ACOUSTICAL FLEXIBLE DUCT UNLESS
OTHERWISE NOTED AND A MAXIMUM LENGTH OF FIVE FEET.
4. ALL ROUND DUCT CONNECTIONS TO ROUND DUCTWORK SHALL BE
CONICAL TEES.
5. ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES.
6. ALL DUCTWORK SHALL BE RUN TIGHT TO UNDERSIDE OF STRUCTURE
WHERE IT EXISTS UNLESS OTHERWISE NOTED.
7. ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL
INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY.
8. ALL SUPPLY GRILLES SHALL HAVE INCLUDE A BALANCING DAMPER
UNLESS OTHERWISE NOTED (EVEN THOUGH THEY MAY NOT BE SHOWN
EVERYWHERE). IF THE DAMPER IS LOCATED IN AN INACCESSIBLE
LOCATION, CABLE-STYLE DAMPERS (ROTOTWIST OR EQUIVALENT) SHALL
BE INSTALLED AND SHALL BE ADJUSTABLE FROM THE GRILLE FACE.
MULTIPLE RETURN DIFFUSERS IF SERVED BY A COMMON RETURN
DUCTWORK SHALL BE EQUIPPED WITH BALANCING DAMPERS.
9. COORDINATE ALL ACCESS PANEL LOCATIONS WITH THE ARCHITECT.
1
2
3
3
4
4
5
5
T
T
T
T
T
TO BB-27 - 34
TO BB-35 - 37
H
TO HRV-3
TO LIGHTS
& HRV-4
H
TO HRV-4
TO BB-38
TO BB-39 - 41
H TO HRV-2
H
TO HRV-2
TO BB-42- 44
TO LIGHTS
& HRV-2
M
BDD
of
Drawn By: Checked By:
DATE: ISSUE:
02-22-16 DD SET
AEC PROJECT #: TOV FIRE STATION #1
RENOVATION
VAIL, COLORADO 81657
16001.00
www.aec-vail.com
CMechanical, Electrical & Lighting Design Services
Architectural Engineering Consultants
Telephone:
970-748-8520
E
G$Q 2IILFH ZLWK /((' $FFUHGLWHG 3URIHVVLRQDOV
03-14-16
PROGRESS
03-22-16
PERMIT
04-01-16
CD SET
/< 61%
.'8'.
*8#%
2.#0
5%#.' Ä
/
NORTH
LEVEL 2 HVAC PLAN
SCALE: 3/16" = 1'0"
06/14/16