HomeMy WebLinkAboutB16-0087_M3.2_1465941600.pdfW D UP DN D E C 5 6 4 1 3 2 7 A B 8 F.1 F.2 F.3 F.4 7.5 A1 4.9 7A 7B 7C DECK DRAIN DECK DRAIN 3rd FLR STORAGE 3rd FLR HALLWAY / STAIRS 3rd FLR BED #1 3rd FLR BED #2 LAUNDRY 3rd FLR BED #3 3rd FLR LIVING 3rd FLR BATH #1 3rd FLR BATH #2 3rd FLR KITCHEN DUTY OFFICE SEE M3.3 PLAN FOR CONTINUATION ON THIS LEVEL HC 1 ERV 1 16x10 L 1 600-EX 36x12 16x10 [18x12]  ‘ A 50-S 10x10  ‘ 10x10 [12x12]  ‘ A 50-S 10x10 A 50-S 10x10 16x10 [19x13] L 2 800-OA 36x12 16x10 16x10 VD B 200-R 14x4 B 100-EX 10x10  ‘  ‘  ‘  ‘  ‘ B 100-EX 10x10  ‘ 83  ‘ 83  ‘  ‘  ‘  ‘  ‘ A 100-S 10x10 A 100-S 10x10 A 200-S 10x10 B 50-EX 10x10  ‘ 83  '1  ‘ 83  '1  ‘  ‘ B 50-EX 10x10 16x10 VD VD VD VD VD (TYP. 4x) VD VD VD (TYP. 3x) SHEET DETAIL NOTES: INSTALL ERV-1 ,1 +25,=217$/ 326,7,21 ƒ 527$7(' 9(5,)< :,7+ MANUFACTURER PRIOR TO ORDERING. INSTALL BDD ON EXHAUST AND O.A. INTAKE DUCTWORK (NOT SHOWN). COORDINATE ACCESS PANEL (MIN. 36x48 OR EQUIVALENT) WITH ARCHITECT AND G.C. IN FIELD. INSTALL HC-1, INTERLOCK 2-WAY MODULATING VALVE WITH THE DUCT MOUNTED SENSOR (IN THE ERV-1 DISCHARGE DUCT). VERIFY COIL DIMENSIONS AND SPACE REQUIREMENTS IN FIELD PRIOR TO COIL PURCHASE. ADJUST SIZE AND CONNECTION SIDE PER FIELD MEASUREMENTS. CONTACT ENGINEER FOR ASSISTANCE IF REQUIRED. INSTALL LOUVERS MIN. 36" ABOVE ROOF OR SNOW LEVEL. IF THE HEIGHT CANNOT BE MAINTAINED PROVIDE ROOF HEAT TRACE TO PROVIDE SNOWMELT. COORDINATE WITH ELECTRICAL CONTRACTOR. PROVIDE DOOR UNDERCUT OR 12x4 TRANSFER GRILLE ABOVE THE DOOR. 1 2 1 2 3 3 3 GENERAL NOTES: 1. ALL DUCTWORK DIMENSIONS ARE SHOWN INSIDE TO INSIDE. DIMENSIONS IN [ ] INDICATE OUTER SIZES WITH INSULATION. THESE SIZES MAY DIFFER BASED ON THE SELECTED INSULATION. VERIFY IN FIELD PRIOR TO INSTALLATION. 2. ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1" LINER UNLESS OTHERWISE NOTED. ALL OUTSIDE AIR INTAKE AND ROUND DUCTWORK SHALL BE WRAPPED WITH 1.5" THICK INSULATION UNLESS OTHERWISE NOTED. 3. ALL FINAL DUCTWORK CONNECTIONS TO SUPPLY GRILLES (OR PLENUMS) SHALL BE COMPLETED WITH ACOUSTICAL FLEXIBLE DUCT UNLESS OTHERWISE NOTED AND A MAXIMUM LENGTH OF FIVE FEET. 4. ALL ROUND DUCT CONNECTIONS TO ROUND DUCTWORK SHALL BE CONICAL TEES. 5. ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES. 6. ALL DUCTWORK SHALL BE RUN TIGHT TO UNDERSIDE OF STRUCTURE WHERE IT EXISTS UNLESS OTHERWISE NOTED. 7. ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY. 8. ALL SUPPLY GRILLES SHALL HAVE INCLUDE A BALANCING DAMPER UNLESS OTHERWISE NOTED (EVEN THOUGH THEY MAY NOT BE SHOWN EVERYWHERE). IF THE DAMPER IS LOCATED IN AN INACCESSIBLE LOCATION, CABLE-STYLE DAMPERS (ROTOTWIST OR EQUIVALENT) SHALL BE INSTALLED AND SHALL BE ADJUSTABLE FROM THE GRILLE FACE. MULTIPLE RETURN DIFFUSERS IF SERVED BY A COMMON RETURN DUCTWORK SHALL BE EQUIPPED WITH BALANCING DAMPERS. 9. COORDINATE ALL ACCESS PANEL LOCATIONS WITH THE ARCHITECT. A 200-S 24x6  ‘  ‘ '1 TO DRYER  ‘ 83 T T T T T T T T T T M TO BB-56, 57 TO BB-58, 59 TO BB-61, 62 TO BB-40 TO BB-45 - 52 TO BB-65 TO BB-63 - 64 TO BB-54 TO BB-55 TO BB-44 BDD 4 4 of Drawn By: Checked By: DATE: ISSUE: 02-22-16 DD SET AEC PROJECT #: TOV FIRE STATION #1 RENOVATION VAIL, COLORADO 81657 16001.00 www.aec-vail.com CMechanical, Electrical & Lighting Design Services Architectural Engineering Consultants Telephone: 970-748-8520 E G$Q 2IILFH ZLWK /(('Œ $FFUHGLWHG 3URIHVVLRQDOV 03-14-16 PROGRESS 03-22-16 PERMIT 04-01-16 CD SET /< 61% .'8'.  *8#% 2.#0 5%#.'   žÄ /   NORTH LEVEL 3 HVAC PLAN SCALE: 3/16" = 1'0" 06/14/16