HomeMy WebLinkAboutB16-0087_M3.4_1465941600.pdfDN D E C 5 6 4 3 2 B F.1 F.3 F.4 7.5 4.9 7B 7C LEVEL 5 STAIRS / HALLWAY LEVEL 5 OFFICE LEVEL 5 BEDROOM LEVEL 5 BATH A 50-S 10x10 B 100-S 10x10  ‘  ‘ '1  ‘ '1 SHEET DETAIL NOTES: TERMINATE RELOCATED PLYMOVENT DUCT MIN. 36" ABOVE THE ROOF (PROVIDE HEAT TRACE FOR SNOWMELT TO REDUCE THE HEIGHT), 24" ABOVE THE HIGHEST POINT OF THE ROOF WITHIN 10', 10' FROM PROPERTY LINE, 10' FROM ANY AIR INTAKE INTO THE BUILDING OR 3' ABOVE IT, AND 10' FROM ANY NATURAL AIR INTAKE INTO THE BUILDING. TERMINATE NEW RADIANT HEATERS VENT MIN. 36" ABOVE THE ROOF (PROVIDE HEAT TRACE FOR SNOWMELT TO REDUCE THE HEIGHT), 24" ABOVE THE HIGHEST POINT OF THE ROOF WITHIN 10', 10' FROM PROPERTY LINE, 10' FROM ANY AIR INTAKE INTO THE BUILDING OR 3' ABOVE IT, 3' FROM ANY NATURAL AIR INTAKE INTO THE BUILDING, AND 12" FROM THE PLYMOVENT TERMINATION OR 12" ABOVE IT. TERMINATE DRYER VENT MIN. 3' ABOVE THE ROOF, 10' FROM PROPERTY LINE, 10' FROM ANY MECHANICAL INTAKE OR 3' ABOVE IT, AND 3' FROM ANY NATURAL INTAKE INTO THE BUILDING. TOTAL DESIGNED LENGTH: VERTICAL RUN = 15 FT HORIZONTAL RUN = 7 FT ƒ (/%2:6 [ = 5 FT TOTAL LENGTH = 27 FT G.C. TO PROVIDE DRYER ALLOWING THIS LENGTH OR INSTALL DRYER ALLOWING LONG VENT INSTALLATION. CONTACT MECHANICAL ENGINEER FOR ASSISTANCE. 1 GENERAL NOTES: 1. ALL DUCTWORK DIMENSIONS ARE SHOWN INSIDE TO INSIDE. DIMENSIONS IN [ ] INDICATE OUTER SIZES WITH INSULATION. THESE SIZES MAY DIFFER BASED ON THE SELECTED INSULATION. VERIFY IN FIELD PRIOR TO INSTALLATION. 2. ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1" LINER UNLESS OTHERWISE NOTED. ALL OUTSIDE AIR INTAKE AND ROUND DUCTWORK SHALL BE WRAPPED WITH 1.5" THICK INSULATION UNLESS OTHERWISE NOTED. 3. ALL FINAL DUCTWORK CONNECTIONS TO SUPPLY GRILLES (OR PLENUMS) SHALL BE COMPLETED WITH ACOUSTICAL FLEXIBLE DUCT UNLESS OTHERWISE NOTED AND A MAXIMUM LENGTH OF FIVE FEET. 4. ALL ROUND DUCT CONNECTIONS TO ROUND DUCTWORK SHALL BE CONICAL TEES. 5. ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES. 6. ALL DUCTWORK SHALL BE RUN TIGHT TO UNDERSIDE OF STRUCTURE WHERE IT EXISTS UNLESS OTHERWISE NOTED. 7. ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY. 8. ALL SUPPLY GRILLES SHALL HAVE INCLUDE A BALANCING DAMPER UNLESS OTHERWISE NOTED (EVEN THOUGH THEY MAY NOT BE SHOWN EVERYWHERE). IF THE DAMPER IS LOCATED IN AN INACCESSIBLE LOCATION, CABLE-STYLE DAMPERS (ROTOTWIST OR EQUIVALENT) SHALL BE INSTALLED AND SHALL BE ADJUSTABLE FROM THE GRILLE FACE. MULTIPLE RETURN DIFFUSERS IF SERVED BY A COMMON RETURN DUCTWORK SHALL BE EQUIPPED WITH BALANCING DAMPERS. 9. COORDINATE ALL ACCESS PANEL LOCATIONS WITH THE ARCHITECT.  ‘ 1 2 2  ‘ 83 7+58 7+( ROOF & DN 3 3 T T T TO BB-73 - 75 TO BB-71, 72 TO BB-69, 70 of Drawn By: Checked By: DATE: ISSUE: 02-22-16 DD SET AEC PROJECT #: TOV FIRE STATION #1 RENOVATION VAIL, COLORADO 81657 16001.00 www.aec-vail.com CMechanical, Electrical & Lighting Design Services Architectural Engineering Consultants Telephone: 970-748-8520 E G$Q 2IILFH ZLWK /(('Œ $FFUHGLWHG 3URIHVVLRQDOV 03-14-16 PROGRESS 03-22-16 PERMIT 04-01-16 CD SET /< 61% .'8'.  '*7 .1(6 *8#% 2.#0 5%#.'   žÄ /   NORTH LEVEL 5 (EHU LOFT) HVAC PLAN SCALE: 3/16" = 1'0" 06/14/16