Loading...
HomeMy WebLinkAboutB16-0087_M4.0_1478903666.pdf1 MECH ROOM BUNKER GEAR 1ST FLR HALLWAY STAIRS PUBLIC RESTROOM UP WD 5 6 4 1 3 2 7 A B 8 7.5 A1 4.9 7A 7B UP GYM CONFERENCE ROOM OFFICE A OFFICE B OFFICE HALLWAY ENTRY APPARATUS BAY CLEAN ROOM STORAGE HALLWAY STORAGE ROOM 2 STORAGE ROOM 1 SHEET DETAIL NOTES: PROPOSED LOCATION OF SM-1 MANIFOLD. VERIFY LOCATION WITH THE G.C. AND/OR OWNER PRIOR TO INSTALLATION. CONNECT 1-1/2" SMS/R TO SM-1. PROPOSED LOCATION OF SM-2 MANIFOLD. VERIFY LOCATION WITH THE G.C. AND/OR OWNER PRIOR TO INSTALLATION. CONNECT 1-1/2" SMS/R TO SM-2. ROUTE 2" SMS/R TO THE MECHANICAL ROOM. CONNECT TO THE MAIN BOILER PIPING. RE: BOILER PIPING DIAGRAM ON M1.3. CONFIRM EXACT LOCATION OF SNOW / ICE SENSOR W/ G.C. LOCATE EQUIDISTANT BETWEEN TUBING & DO NOT LOCATE UNDER AN OVERHANG. EPO SZ 1 SZ 2 1445 SQFT 1445 SQFT SM 2 SM 1 P 6 B-2 B-1 GF-1 WH-1 2" SMS/R 2" SMS/R 2" SMS/R 1-1/2" SMS/R 1-1/2" SMS/R GENERAL NOTES: 1. OFFSET PIPING AS REQUIRED TO AVOID ALL DUCTWORK, LIGHTS, AND STRUCTURE. COORDINATE ALL STRUCTURAL PENETRATIONS WITH THE STRUCTURAL ENGINEER. 2. ALL PIPING PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE A FIRE-RATED PIPE SEALANT RATED TO MATCH THAT OF THE ASSEMBLY. 3. ALL MECHANICAL PIPING SHOWN DASHED SHALL BE LOCATED BELOW THE FLOOR DECK. 4. VERIFY FINAL LOCATIONS OF ALL MANIFOLDS WITH THE G.C. CONTACT ENGINEER IF MANIFOLDS MOVE MORE THAN 5' (OR AS QUOTED IN THE SNOWMELT SCHEDULE ON M1.1) FROM LOCATIONS SHOWN ON PLANS. 5. LOCATION OF ALL THERMOSTATS AND SENSORS ARE APPROXIMATE, COORDINATE EXACT LOCATIONS WITH THE ARCHITECT. LOCATE SM SENSOR EQUIDISTANT BETWEEN LOOPS, AND DO NOT LOCATE WHERE IT MAY LIKELY BE COVERED BY OVERHANGS, TREES, OR ANY OTHER OBSTACLES . 6. ALL PIPING SIZED FOR TYPE L COPPER, SNOWMELT TUBING SIZED FOR APPROPRIATE aPEX WITH OXYGEN BARRIER. CONTACT ENGINEER FOR ANY CHANGE TO PEX FOR NECESSARY PIPE SIZING AND/OR PUMP CHANGES. 1 2 2 3 3 7B C 7C D F.3 F.4 E F.1 F.2 S SNOWMELT SENSOR 090/091 TO SNOWMELT CONTROLLER RE: BOILER PIPING DIAGRAM ON M1.3 GF-2 HX-1 4 4 of Drawn By: Checked By: DATE: ISSUE: 02-22-16 DD SET AEC PROJECT #: TOV FIRE STATION #1 RENOVATION VAIL, COLORADO 81657 16001.00 www.aec-vail.com CMechanical, Electrical & Lighting Design Services Architectural Engineering Consultants Telephone: 970-748-8520 E G$Q 2IILFH ZLWK /(('Œ $FFUHGLWHG 3URIHVVLRQDOV 03-14-16 PROGRESS 03-22-16 PERMIT 04-01-16 CD SET /< 61% .'8'.  5019/'.6 2.#0 5%#.'   žÄ /   NORTH LEVEL 1 SNOWMELT PLAN SCALE: 3/16" = 1'0" 06/14/16