HomeMy WebLinkAboutB16-0087_P1.1_1465941600.pdfƒ ) P 1 WH 1  ) PROPORTIONAL THERMOSTATIC 0,;,1* 9$/9( ƒ) CONTINUED ON BACK SIDE TO OUTLET SLOPED TO DRAIN OUT TO FD ƒ ) 1-1/4" CW 3/4" DN TO MOP SINK BASIN  ƒ) +: 1/2" HOT WATER CIRC. FROM FIXTURES 1-1/4" COLD WATER SUPPLY 1-1/4" HOT WATER TO FIXTURES D INDIRECT WATER HEATER DIAGRAM NO SCALE 1-1/4" CW BOILER SUPPLY/ RETURN A AQUA-STAT TO BOILER PUMP AMTROL THERM-X-TROL ST-12-C WASTE LINE CLEANOUT SCHEMATICS NO SCALE CLEANOUT AND ACCESS COVER. TOP OF COVER TO BE FLUSH W/TOP OF FLOOR FLOOR LINE BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. 1/8 C.I. BEND FLOOR CLEANOUT (FCO) CLEANOUT NOT TO BE LOCATED IN CARPETED AREA. CLEANOUT TO GRADE (COTG) 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE. C.I. WASTE LINE. LGTH TO SUIT. 1/8 C.I. BEND FINISHED GRADE BRASS CLEANOUT PLUG W/COUNTER SUNK HEAD ‘ &21& 3$' 752:(/ SMOOTH & EDGE TYPICAL LOW PRESSURE GAS CONNECTION DETAIL NO SCALE GAS SHUT OFF VALVE TYP. LOW PRESSURE GAS LINE 6" MIN. DRIP LEG MECHANICAL EQUIPMENT TYPICAL OF INSULATION -VARIES AS PER DEPTH TREATED WOOD NAILER - AS REQUIRED BY VARIOUS STACK NOTE: COORDINATE FLASHING SIZES CL SIZES INSULATION CAP TO SLIDE OVER BASE SHOP FABRICATE LEAD JACK  9(17 ‘ C L IN MASTIC W/2 PLY OVER FLANGE - OVER FINISHED FELTS STRIPPING IN MASTIC LEAD JACK W FLANGE TYPICAL PROVIDE MIN. 1" LARGER "PATE" TYPE PLASTIC ROOF CURBS ARE AN APPROVED EQUIVALENT EXTEND VENT INCREASER A MIN. OF 12" BELOW ROOF 12" 18" MIN. ,1&5($6(5 $%29( 9(17 ‘ ROOF VENT THRU ROOF DETAIL NO SCALE P/T P/T CIRC PUMP HW RE-CIRCULATOR PUMP DIAGRAM SCALE CIRCUIT SETTER PRESSURE GAUGE W/ GAUGE COCKS PROVIDE PUMP SUPPORT AT INLET & DISCHARGE PIPING - DO NOT SUPPORT FROM PUMP MOTOR UNION OR FLANGE CONNECTION SHUTOFF VALVE D STRAINER RPBFP-1 #8 BARE COPPER WIRE WATER SERVICE BY THE CIVIL CONTRACTOR. RE: CIVIL PLAN FOR CONTINUATION, EXACT SIZE, LOCATION & INVERT ELEVATIONS. ANCHOR PIPING TO WALL TO WALL ANCHOR PIPING RPBFP-1:WILKINS ROUTE DN TO F.D. OR BASIN PRV: PRESSURE REDUCING VALVE REFERENCE THE ELECTRICAL DOCUMENTS FOR GROUNDING DETAILS ANCHOR PIPING TO WALL MAIN DOMESTIC WATER ENTRY DETAIL NO SCALE 1-1/2" 1-1/2" 4" FIRE PROTECTION SYSTEM, PIPING & EQUIPMENT PROVIDED BY DESIGN BUILD FIRE PROTECTION CONTRACTOR. F.P.C. TO VERIFY PIPE SIZING PRIOR TO INSTALLATION. COORDINATE WITH TOWN OF STEAMBOAT PUBLIC WORKS 2-3 FEET MINIMUM OF FIVE DIAMETERS OF STRAIGHT PIPE M MAIN SHUT OFF VALVE LOCATE WITHIN 5' OF THE ENTRY INTO THE BUILDING LINK SEAL PROVIDE APPROVED VERTICAL JOINT RESTRAINTS AS REQUIRED 4" of Drawn By: Checked By: DATE: ISSUE: 02-22-16 DD SET AEC PROJECT #: TOV FIRE STATION #1 RENOVATION VAIL, COLORADO 81657 16001.00 www.aec-vail.com CMechanical, Electrical & Lighting Design Services Architectural Engineering Consultants Telephone: 970-748-8520 E G$Q 2IILFH ZLWK /(('Œ $FFUHGLWHG 3URIHVVLRQDOV 03-14-16 PROGRESS 03-22-16 PERMIT 04-01-16 CD SET ') 61% 2.7/$+0) &'6#+.5 2   06/14/16