HomeMy WebLinkAboutB16-0087_P1.1_1478903670.pdf )
P
1
WH
1
)
PROPORTIONAL THERMOSTATIC
0,;,1* 9$/9( )
CONTINUED ON
BACK SIDE TO
OUTLET
SLOPED TO
DRAIN OUT
TO FD
)
1-1/4" CW
3/4" DN TO MOP
SINK BASIN
) +:
1/2" HOT WATER CIRC.
FROM FIXTURES
1-1/4" COLD WATER SUPPLY
1-1/4" HOT WATER TO FIXTURES
D
INDIRECT WATER HEATER DIAGRAM
NO SCALE
1-1/4" CW
BOILER
SUPPLY/ RETURN
A
AQUA-STAT TO
BOILER PUMP
AMTROL
THERM-X-TROL
ST-12-C
WASTE LINE
CLEANOUT SCHEMATICS
NO SCALE
CLEANOUT AND ACCESS
COVER. TOP OF COVER
TO BE FLUSH W/TOP OF
FLOOR
FLOOR
LINE
BALANCE OF PIPING
SAME AS CLEANOUT
TO GRADE.
1/8 C.I. BEND
FLOOR CLEANOUT (FCO)
CLEANOUT NOT TO BE LOCATED
IN CARPETED AREA.
CLEANOUT TO GRADE (COTG)
1/8 BEND IF CLEANOUT
OCCURS AT END OF
LINE.
C.I. WASTE LINE.
LGTH TO SUIT.
1/8 C.I. BEND
FINISHED GRADE
BRASS CLEANOUT PLUG
W/COUNTER SUNK HEAD
&21& 3$' 752:(/
SMOOTH & EDGE
TYPICAL LOW PRESSURE
GAS CONNECTION DETAIL
NO SCALE
GAS SHUT OFF VALVE
TYP.
LOW PRESSURE
GAS LINE
6" MIN. DRIP LEG
MECHANICAL
EQUIPMENT
TYPICAL
OF INSULATION -VARIES AS PER DEPTH
TREATED WOOD NAILER -
AS REQUIRED BY VARIOUS STACK
NOTE: COORDINATE FLASHING SIZES
CL
SIZES
INSULATION
CAP TO SLIDE OVER BASE
SHOP FABRICATE LEAD
JACK
9(17
C
L
IN MASTIC W/2 PLY
OVER FLANGE -
OVER FINISHED FELTS
STRIPPING IN MASTIC
LEAD JACK W FLANGE
TYPICAL
PROVIDE MIN. 1" LARGER
"PATE" TYPE PLASTIC ROOF CURBS ARE AN APPROVED EQUIVALENT
EXTEND VENT INCREASER
A MIN. OF 12" BELOW ROOF
12"
18" MIN.
,1&5($6(5 $%29( 9(17
ROOF
VENT THRU ROOF DETAIL
NO SCALE
P/T
P/T
CIRC
PUMP
HW RE-CIRCULATOR
PUMP DIAGRAM
SCALE
CIRCUIT SETTER
PRESSURE GAUGE
W/ GAUGE COCKS
PROVIDE PUMP SUPPORT
AT INLET & DISCHARGE
PIPING - DO NOT SUPPORT
FROM PUMP MOTOR
UNION OR FLANGE
CONNECTION
SHUTOFF VALVE
D
STRAINER RPBFP-1
#8 BARE COPPER
WIRE
WATER SERVICE BY THE CIVIL CONTRACTOR. RE:
CIVIL PLAN FOR CONTINUATION, EXACT SIZE,
LOCATION & INVERT ELEVATIONS.
ANCHOR PIPING
TO WALL
TO WALL
ANCHOR PIPING
RPBFP-1:WILKINS
ROUTE DN TO F.D. OR BASIN
PRV: PRESSURE REDUCING
VALVE
REFERENCE THE
ELECTRICAL
DOCUMENTS FOR
GROUNDING DETAILS
ANCHOR PIPING
TO WALL
MAIN DOMESTIC WATER ENTRY DETAIL
NO SCALE
1-1/2"
1-1/2"
4" FIRE PROTECTION SYSTEM, PIPING & EQUIPMENT
PROVIDED BY DESIGN BUILD FIRE PROTECTION
CONTRACTOR. F.P.C. TO VERIFY PIPE SIZING PRIOR
TO INSTALLATION. COORDINATE WITH TOWN OF
STEAMBOAT PUBLIC WORKS
2-3 FEET
MINIMUM OF
FIVE DIAMETERS
OF STRAIGHT
PIPE
M
MAIN SHUT OFF VALVE
LOCATE WITHIN 5' OF THE
ENTRY INTO THE BUILDING
LINK SEAL
PROVIDE APPROVED VERTICAL
JOINT RESTRAINTS AS REQUIRED
4"
of
Drawn By: Checked By:
DATE: ISSUE:
02-22-16 DD SET
AEC PROJECT #: TOV FIRE STATION #1
RENOVATION
VAIL, COLORADO 81657
16001.00
www.aec-vail.com
CMechanical, Electrical & Lighting Design Services
Architectural Engineering Consultants
Telephone:
970-748-8520
E
G$Q 2IILFH ZLWK /((' $FFUHGLWHG 3URIHVVLRQDOV
03-14-16
PROGRESS
03-22-16
PERMIT
04-01-16
CD SET
') 61%
2.7/$+0)
&'6#+.5
2
06/14/16