HomeMy WebLinkAboutB16-0087_P2.0_1478901809.pdfGENERAL NOTES:
1. OFFSET PIPING AS REQUIRED TO AVOID ALL DUCTWORK, LIGHTS, AND
STRUCTURE. COORDINATE ALL STRUCTURAL PENETRATIONS WITH THE
STRUCTURAL ENGINEER.
2. ALL PIPING PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE
A FIRE-RATED PIPE SEALANT RATED TO MATCH THAT OF THE ASSEMBLY.
3. INSTALL CLEANOUTS PER SECTION 708 OF THE IPC. NOT ALL REQUIRED
CLEANOUTS NECESSARILY SHOWN. COORDINATE ALL FINAL LOCATIONS
WITH THE ARCHITECT PRIOR TO INSTALLATION.
4. ALL WASTE PIPING SHOWN AS DASHED IS TO BE ROUTED UNDERSLAB.
MECH
ROOM
BUNKER GEAR
1ST FLR HALLWAY
STAIRS
PUBLIC
RESTROOM
UP
WD
D E C
5
6
4
1
3
2
7
A
B
8
F.1 F.2
F.3 F.4
7.5
A1
4.9
7A
7B
7C
UP
GYM
CONFERENCE
ROOM
OFFICE
A
OFFICE
B
OFFICE
HALLWAY
ENTRY
APPARATUS BAY
CLEAN
ROOM
STORAGE
HALLWAY
STORAGE
ROOM 2
STORAGE
ROOM 1
WC-1
LV-1
CWB-1
DRYER
LS-1
EYE WASH
STATION
CONNECT 1-1/2" W & 1-1/2" V TO LV-1.
CONNECT 3" W & 2" V TO WC-1.
CONNECT 2" W & 1-1/2" V TO FD-1.
CONNECT 2" W & 1-1/2" V TO LS-1.
CONNECT 2" W & 1-1/2" V TO CWB-1.
ROUTE TO TREATMENT TANK RE: CIVIL.
(E) MANHOLES TO BE RE-USED AS FLOOR DRAINS OR
ABANDONED.
CONNECT 4" SD TO FD-2.
3" W FROM FLOOR ABOVE.
EXISTING TRENCH DRAIN TO REMAIN, RE: CIVIL
PLANS.
EXISTING 6" WASTE. VERIFY EXACT LOCATION &
INVERT IN FIELD PRIOR TO CONNECTING TO IT.
3" W FROM WC-1 ABOVE.
4" W FROM FLOOR ABOVE. REUSE THE EXISTING
STANDPIPE IN THIS LOCATION.
SHEET DETAIL NOTES:
1
2
1
2
5
4
3
4
5
(E)TRENCH DRAIN
8411.12 I.E.
8411.16 I.E.
8410.58 I.E.
3
1-1/2" V
1-1/2" V
3" V TO
FLOOR
ABOVE
2" VTR
1-1/2" V
WH-1
FD-1
3" W
3" W
4" W
4" W
6" W
3" W
2" W
3" W
3" W
6" SD
6" SD
6" SD
6" SD
3" W
3" W
3" W
3" W
FD-1
6
6
CO
WCO
3
FD-1
3
7
7
7
(E) MANHOLES
(E) MANHOLES
2" W
2" W
3" W
FD-2
FD-2
8
8
8
4" SD
4" SD
3" SD UP TO DD-1.
9
9
12
9
10
10
11
11
12
3" VTR
FD-2
8
2" V
2" V
13
13
2" V
CO
of
Drawn By: Checked By:
DATE: ISSUE:
02-22-16 DD SET
AEC PROJECT #: TOV FIRE STATION #1
RENOVATION
VAIL, COLORADO 81657
16001.00
www.aec-vail.com
CMechanical, Electrical & Lighting Design Services
Architectural Engineering Consultants
Telephone:
970-748-8520
E
G$Q 2IILFH ZLWK /((' $FFUHGLWHG 3URIHVVLRQDOV
03-14-16
PROGRESS
03-22-16
PERMIT
04-01-16
CD SET
') 61%
.'8'.
9#56'
8'06 2.#0
5%#.' Ä
2
NORTH
LEVEL 1 WASTE & VENT PLAN
SCALE: 3/16" = 1'0"
06/14/16