HomeMy WebLinkAboutB16-0087_P2.4_1478903677.pdfDN D E C 5 6 4 3 2 B F.1 F.3 F.4 7.5 4.9 7B 7C LEVEL 5 STAIRS / HALLWAY LEVEL 5 OFFICE LEVEL 5 BEDROOM LEVEL 5 BATH SH-1 WC-1 LV-1 1 GENERAL NOTES: 1. OFFSET PIPING AS REQUIRED TO AVOID ALL DUCTWORK, LIGHTS, AND STRUCTURE. COORDINATE ALL STRUCTURAL PENETRATIONS WITH THE STRUCTURAL ENGINEER. 2. ALL PIPING PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE A FIRE-RATED PIPE SEALANT RATED TO MATCH THAT OF THE ASSEMBLY. 3. INSTALL CLEANOUTS PER SECTION 708 OF THE IPC. NOT ALL REQUIRED CLEANOUTS NECESSARILY SHOWN. COORDINATE ALL FINAL LOCATIONS WITH THE ARCHITECT PRIOR TO INSTALLATION. CONNECT 1-1/2" W & 1-1/2" V TO LV-1. ROUTE 1-1/2" W TO WC-1 WASTE LINE & PENETRATE TO FLOOR BELOW. CONNECT 3" W & 2" V TO WC-1. ROUTE & PENETRATE 3" W TO FLOOR BELOW. CONNECT 2" W & 1-1/2" V TO SH-1. SHEET DETAIL NOTES: 1 2 2 3 3 1-1/2" W 3" VTR 3" VTR 3" VTR 3" V 1-1/2" V 2" V of Drawn By: Checked By: DATE: ISSUE: 02-22-16 DD SET AEC PROJECT #: TOV FIRE STATION #1 RENOVATION VAIL, COLORADO 81657 16001.00 www.aec-vail.com CMechanical, Electrical & Lighting Design Services Architectural Engineering Consultants Telephone: 970-748-8520 E G$Q 2IILFH ZLWK /(('Œ $FFUHGLWHG 3URIHVVLRQDOV 03-14-16 PROGRESS 03-22-16 PERMIT 04-01-16 CD SET ') 61% .'8'.  '*7 .1(6 9#56'  8'06 2.#0 5%#.'   žÄ 2   NORTH LEVEL 5 (EHU LOFT) WASTE & VENT PLAN SCALE: 3/16" = 1'0" 06/14/16