HomeMy WebLinkAboutB17-0098_A6.1_1493330220.pdfDRAINAGE MEDIUM OVER CONT. W.P. MEMBRANE
SLOPE PER PLAN
CENTER DRAIN RE: PLAN
EXISTING WALL ASSEMBLY
REMOVE EXISTING STONE ABOVE PATIO TO
INSTALL NEW W.P. MEMBRANE AND DRAINAGE
APPROX. 18" UP WALL.
4" ASSEMBLY CONSISTS OF 2"+/- FLAGSTONE TO MATCH
EXISTING OVER +/- 1 1/2" GROUT OVER 1/2" ASSEMBLY OF
CONTINUOUS DRAINAGE MEDIUM (RE: SPEC) AND CONT.
W.P. DECK MEMBRANE. PROVIDE HEAT TUBE ATTACHED
TO WELDED WIRE MESH IN 1 1/2" GROUT BED. (RE: SPEC).
LAP DRAINAGE MEDIUM OVER FLASHING OVER
CONTINUOUS W.P. MEMBRANE
2" RIGID INSULATION.
SECURE TO UNDERSIDE
OF SLAB W/ WIRE TIES.
STL. ANGLE SUPPORT. RE: STRUCT.
DRAIN: ZURN Z158-85 PER W.P. CONSULT. 2"
INTERIOR
8" 0" 5" MIN.
6" MAX
1/2" X 1/2" SAWCUT INTO CONC SLAB IN
ORDER TO KEY NEW W.P. MEMBRANE
EXISTING SLAB ON GRADE
STAINLESS STL. THREADED ROD.
NUT
FLAT CLAMPING COLLAR
DRAINAGE MAT
W.P. MEMBRANE
SETUP DRAIN BOWL INTO SLAB
10" SQ.
8 7/8" SQ.
SLOPE PER PLAN
SEE SPEC.
FILTER FABRIC
COORDINATE PERFORATED
RISER HEIGHT W/ PAVEMENT
HEIGHT @ DRAIN.
SLOPE PER PLAN
NEW 5" STONE VENEER TO MATCH EXISTING
EXIST. 6" CMU CONSTRUCTION. VIF. REPLACE IF WOOD STRUCTURE
REUSE EXISTING STONE CAP. SLOPE TO SHED WATER
DRAINAGE MEDIUM OVER CONT. W.P.
MEMBRANE
NEW TOPPING SLAB TO SLOPE
STONE PATIO TO NEW DRAINS
EXIST. STRUCT. SLAB
1/2" RESILIENT CHANNEL
STUCCO CLG. REMOVE
EXIST. & REPLACE AS REQ'D
SLOPE PER PLAN
CENTER DRAIN RE: PLAN
REMOVE EXISTING STONE @ INSIDE OF WALL & TOP
PORTION OF STONE @ OUTISDE OF WALL TO LAP
NEW W.P. MEMBRANE OVER T.O. WALL .
EXIST. STL. BEAM. V.I.F.
5/8" P.T. PLYWOOD
DRAINAGE MEDIUM RE:SPEC.
EXIST. INSULATION
SLOPE @ 2%
LAMINATED FOIL FLASHING WITH BUTYL BASE. RE: SPEC
STAINLESS STEEL PIN TO SECURE STONE CAP
COPPER FLASHING W/ HEMMED EDGE W/
COTTEN WICKS 20" X 16" O.C.
DRAIN: ZURN Z158-85 PER W.P. CONSULT;
WRAP PERFORATED RISER W/ FILTER
FABRIC; PROVIDE LOWER FLAT CLAMPING
COLLAR AND SECURE WP.M. TO DRAIN
BOWL; USE S.S. THREADED RODS.
3" MIN.
FILTER FABRIC.
NEW W.P. MEMBRANE WRAPS UP WALL AND OVER THE
TOP OF CMU WALL & LAPS OVER EXIST. W.P. MEMBRANE
3' - 4 1/2"
NEW 4" STONE ASSEMBLY- APPROX 1 1/2" OF
STONE OVER 1" OF GROUT OVER 1 1/2" CONC.
TOPPING SLAB WITH REPLACED RADIANT TUBING
EXIST. STONE PAVERS
SLOPE PER PLAN
8"
REMOVE 18" MIN OF EXIST. FLAGSTONE AND
LAP NEW W.P. MEMBRANE OVER EXISTING.
1' - 6"
NEW W.P. MEMBRANE LAPS OVER
EXIST. W.P. MEMBRANE 18" MIN.
NEW 4" STONE ASSEMBLY- APPROX 1 1/2" OF
STONE OVER 1" OF GROUT OVER 1 1/2" CONC.
TOPPING SLAB WITH REPLACED RADIANT
TUBING
1"
1' - 0"
EXTERIOR
UNCONDITIONED SPACE
EXIST. ASSEMBLY TO REMIAN
REPLACE FLAGSTONE, W.P.
MEMBRANE, TOPPING, AND SNOWMELT
EXIST. ASSEMBLY TO REMIAN
REPLACE FLAGSTONE, W.P.
MEMBRANE, TOPPING, AND SNOWMELT 7 5/16"
EXIST. CONC. STAIRS
US Mail Only: P. O. Box 2378
Physical / Fedex: 210 Edwards
Village Blvd, Bldg A Suite A103
Edwards, Colorado 81632-2378
(970) 926 4301, Fax: 926 4364
hans@berglundarchitects.com
www . berglundarchitects.com
Scale
Date
Drawn by
Checked by
Issue Date 3/28/2017 3:15:52 PM
As indicated
84 BEAVER DAM REMODEL
VAIL, CO
A6.1
DETAILS
3-28-2017
CPM
HB
3-28-2017
PROGRESS SET
1 1/2" = 1'-0"
3
LOWER LEVEL COURTYARD DETAIL @
EXTERIOR WALL
6" = 1'-0"
4 ZURN Z158-85 DRAIN DETAIL
1 1/2" = 1'-0"
1
MAIN LEVEL ENTRY STAIR DETAIL
REVISION SCHEDULE
# DESCRIPTION DATE
3" = 1'-0"
2
ENTRY STAIR TO EXISTING TERRACE
CONNECTION DETAIL @ MAIN LEVEL
04/27/17