HomeMy WebLinkAboutB17-0098_A6.1_1493330220.pdfDRAINAGE MEDIUM OVER CONT. W.P. MEMBRANE SLOPE PER PLAN CENTER DRAIN RE: PLAN EXISTING WALL ASSEMBLY REMOVE EXISTING STONE ABOVE PATIO TO INSTALL NEW W.P. MEMBRANE AND DRAINAGE APPROX. 18" UP WALL. 4" ASSEMBLY CONSISTS OF 2"+/- FLAGSTONE TO MATCH EXISTING OVER +/- 1 1/2" GROUT OVER 1/2" ASSEMBLY OF CONTINUOUS DRAINAGE MEDIUM (RE: SPEC) AND CONT. W.P. DECK MEMBRANE. PROVIDE HEAT TUBE ATTACHED TO WELDED WIRE MESH IN 1 1/2" GROUT BED. (RE: SPEC). LAP DRAINAGE MEDIUM OVER FLASHING OVER CONTINUOUS W.P. MEMBRANE 2" RIGID INSULATION. SECURE TO UNDERSIDE OF SLAB W/ WIRE TIES. STL. ANGLE SUPPORT. RE: STRUCT. DRAIN: ZURN Z158-85 PER W.P. CONSULT. 2" INTERIOR 8" 0" 5" MIN. 6" MAX 1/2" X 1/2" SAWCUT INTO CONC SLAB IN ORDER TO KEY NEW W.P. MEMBRANE EXISTING SLAB ON GRADE STAINLESS STL. THREADED ROD. NUT FLAT CLAMPING COLLAR DRAINAGE MAT W.P. MEMBRANE SETUP DRAIN BOWL INTO SLAB 10" SQ. 8 7/8" SQ. SLOPE PER PLAN SEE SPEC. FILTER FABRIC COORDINATE PERFORATED RISER HEIGHT W/ PAVEMENT HEIGHT @ DRAIN. SLOPE PER PLAN NEW 5" STONE VENEER TO MATCH EXISTING EXIST. 6" CMU CONSTRUCTION. VIF. REPLACE IF WOOD STRUCTURE REUSE EXISTING STONE CAP. SLOPE TO SHED WATER DRAINAGE MEDIUM OVER CONT. W.P. MEMBRANE NEW TOPPING SLAB TO SLOPE STONE PATIO TO NEW DRAINS EXIST. STRUCT. SLAB 1/2" RESILIENT CHANNEL STUCCO CLG. REMOVE EXIST. & REPLACE AS REQ'D SLOPE PER PLAN CENTER DRAIN RE: PLAN REMOVE EXISTING STONE @ INSIDE OF WALL & TOP PORTION OF STONE @ OUTISDE OF WALL TO LAP NEW W.P. MEMBRANE OVER T.O. WALL . EXIST. STL. BEAM. V.I.F. 5/8" P.T. PLYWOOD DRAINAGE MEDIUM RE:SPEC. EXIST. INSULATION SLOPE @ 2% LAMINATED FOIL FLASHING WITH BUTYL BASE. RE: SPEC STAINLESS STEEL PIN TO SECURE STONE CAP COPPER FLASHING W/ HEMMED EDGE W/ COTTEN WICKS 20" X 16" O.C. DRAIN: ZURN Z158-85 PER W.P. CONSULT; WRAP PERFORATED RISER W/ FILTER FABRIC; PROVIDE LOWER FLAT CLAMPING COLLAR AND SECURE WP.M. TO DRAIN BOWL; USE S.S. THREADED RODS. 3" MIN. FILTER FABRIC. NEW W.P. MEMBRANE WRAPS UP WALL AND OVER THE TOP OF CMU WALL & LAPS OVER EXIST. W.P. MEMBRANE 3' - 4 1/2" NEW 4" STONE ASSEMBLY- APPROX 1 1/2" OF STONE OVER 1" OF GROUT OVER 1 1/2" CONC. TOPPING SLAB WITH REPLACED RADIANT TUBING EXIST. STONE PAVERS SLOPE PER PLAN 8" REMOVE 18" MIN OF EXIST. FLAGSTONE AND LAP NEW W.P. MEMBRANE OVER EXISTING. 1' - 6" NEW W.P. MEMBRANE LAPS OVER EXIST. W.P. MEMBRANE 18" MIN. NEW 4" STONE ASSEMBLY- APPROX 1 1/2" OF STONE OVER 1" OF GROUT OVER 1 1/2" CONC. TOPPING SLAB WITH REPLACED RADIANT TUBING 1" 1' - 0" EXTERIOR UNCONDITIONED SPACE EXIST. ASSEMBLY TO REMIAN REPLACE FLAGSTONE, W.P. MEMBRANE, TOPPING, AND SNOWMELT EXIST. ASSEMBLY TO REMIAN REPLACE FLAGSTONE, W.P. MEMBRANE, TOPPING, AND SNOWMELT 7 5/16" EXIST. CONC. STAIRS US Mail Only: P. O. Box 2378 Physical / Fedex: 210 Edwards Village Blvd, Bldg A Suite A103 Edwards, Colorado 81632-2378 (970) 926 4301, Fax: 926 4364 hans@berglundarchitects.com www . berglundarchitects.com Scale Date Drawn by Checked by Issue Date 3/28/2017 3:15:52 PM As indicated 84 BEAVER DAM REMODEL VAIL, CO A6.1 DETAILS 3-28-2017 CPM HB 3-28-2017 PROGRESS SET 1 1/2" = 1'-0" 3 LOWER LEVEL COURTYARD DETAIL @ EXTERIOR WALL 6" = 1'-0" 4 ZURN Z158-85 DRAIN DETAIL 1 1/2" = 1'-0" 1 MAIN LEVEL ENTRY STAIR DETAIL REVISION SCHEDULE # DESCRIPTION DATE 3" = 1'-0" 2 ENTRY STAIR TO EXISTING TERRACE CONNECTION DETAIL @ MAIN LEVEL 04/27/17