HomeMy WebLinkAboutB17-0120_BLDG 9 S2_1493937600.pdf8. NON-STRUCTURAL ELEMENTS A. ELEMENTS SUCH AS NON-BEARING PARTITIONS, ETC. ATTACHED TO AND/OR SUPPORTED BY THE STRUCTURE SHALL TAKE INTO ACCOUNT DEFLECTIONS AND OTHER STRUCTURAL MOVEMENT. B. FIRE PROTECTION FOR ALL STRUCTURAL ITEMS SHALL MEET CODE REQUIREMENTS FOR THE TYPE OF CONSTRUCTION SPECIFIED ON THE ARCHITECTURAL DRAWINGS. 9. GENERAL A. ENGINEER'S ACCEPTANCE SHALL BE SECURED FOR ALL STRUCTURAL SUBSTITUTIONS. B. WATERPROOFING, VAPOR BARRIERS, ETC. SHALL BE AS SHOWN ON THE ARCHITECTURAL DRAWINGS AND AS INDICATED IN THE SPECIFICATIONS. C. ALL MASONRY AND STONE VENEERS SHALL BE ATTACHED TO INTERIOR OR EXTERIOR WALLS AS SPECIFIED IN SECTION 1405 OF THE INTERNATIONAL BUILDING CODE. D. ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST EXISTING FIELD CONDITIONS AND/OR ARCHITECTURAL DRAWINGS. DO NOT SCALE DRAWINGS. PROJECT: A REMODEL FOR SANDSTONE 70 G3 # 1704 DATE: JANUARY 17, 2017 1. LIVE LOADS USED IN DESIGN: A. ROOF < 4:12 PITCH: 100 psf B. ROOF > 4:12 PITCH: 80 psf C. DECKS & STAIRS: 100 psf D. IMPORTANCE FACTORS DESIGN CATEGORY: II SEISMIC FACTOR (IE): 1.0 SNOW FACTOR (IS): 1.0 WIND FACTOR (IW): 1.0 E. WIND Vult: 115 MPH Vasd: 89.1 MPH WIND FACTOR: 1.0 F. SNOW GROUND SNOW LOAD (Pg): 100 PSF FLAT ROOF SNOW LOAD (Pf): 100 PSF EXPOSURE FACTOR (Ce): 1.0 THERMAL FACTOR (Ct): 1.0 G. SEISMIC: SITE CLASS: D DESIGN CATEGORY: II SS 0.35 S1: 0.07 SDS: 0.35 SD1: 0.111 SEISMIC RESPONSE COEFFICIENT (Cs): 0.07 RESPONSE MODIFICATION FACTOR (R): 6 ANALYSIS PROCEDURE: SIMPLIFIED METHOD BASIC LATERAL FORCE RESISTING SYSTEM IS LIGHT FRAME WOOD SHEAR WALLS I. BUILDING CODE USED IN DESIGN: 2012 IRC 2. TESTING, INSPECTIONS AND OBSERVATIONS: A. PERIODIC OBSERVATIONS OF CONSTRUCTION BY THE STRUCTURAL ENGINEER SHALL NOT REPLACE REQUIRED INSPECTIONS BY THE GOVERNING AUTHORITY OR SERVE AS "SPECIAL INSPECTIONS" AS MAY BE REQUIRED BY CHAPTER 17 OF THE INTERNATIONAL BUILDING CODE. 3. FOUNDATIONS A. MAXIMUM ALLOWABLE SOIL BEARING PRESSURE ASSUMED IN DESIGN IS 2000 PSF. CONTRACTOR SHALL RETAIN A STATE LICENSED SOILS ENGINEER TO VERIFY IN WRITING THAT THE ACTUAL BEARING CAPACITY IS GREATER THAN OR EQUAL TO THE ASSUMED VALUE. B. ALL FOOTING BEARING ELEVATIONS SHOWN ON THE CONSTRUCTION DOCUMENTS ARE ASSUMED TO BEAR ON UNDISTURBED NATURAL SOIL. ACTUAL FIELD CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR AND APPROVED BY THE SOILS ENGINEER PRIOR TO PLACING CONCRETE. THE BOTTOM OF ALL EXTERIOR FOOTINGS SHALL BE A MINIMUM OF 4'-0" BELOW FINISHED GRADE. C. CONTRACTOR SHALL NOTIFY SOILS ENGINEER AFTER EXCAVATION IS COMPLETE SO THAT CONDITIONS MAY BE REVIEWED PRIOR TO PLACEMENT OF ANY FILL OR CONCRETE. 4. SLAB ON GRADE A. THE PREPARATION OF THE SUB-GRADE FOR THE SLAB ON GRADE SHALL BE PERFORMED IN STRICT ACCORDANCE WITH THE PROJECT SOILS REPORT RECOMMENDATIONS. CONTRACTOR SHALL DIRECT ALL QUESTIONS REGARDING SUB-GRADE PREPARATION TO THE GEOTECHNICAL ENGINEER. B. MOVEMENT OF THE SLAB ON GRADE MAY CAUSE DAMAGE TO ANYTHING CONNECTED TO BOTH THE SLAB AND TO OTHER PORTIONS OF THE STRUCTURE. ISOLATION DETAILS FOR NON-BEARING PARTITIONS, BASEBOARDS, PIPING AND OTHER SENSITIVE ITEMS MAY BE REQUIRED. REFER TO THE APPROPRIATE DRAWINGS AND/OR CONSULT WITH THE RESPONSIBLE MEMBER OF THE DESIGN TEAM PRIOR TO CONNECTING ITEMS TO BOTH THE SLAB ON GRADE AND OTHER PORTIONS OF THE STRUCTURE. PROVIDE SLIP SHEETS BETWEEN SLABS AND ANY BRITTLE FLOOR FINISHES. 5. CONCRETE D. ALL CAST-IN-PLACE CONCRETE SHALL BE MADE WITH TYPE I/II PORTLAND CEMENT, STONE AGGREGATE, AND SHALL SATISFY THE FOLLOWING REQUIREMENTS: CONCRETE ITEM F'c MIX TYPE MAX. W/C RATIO % AIR FOOTINGS/PIERS 3000 psi STD. N/A N/A EXTERIOR CONCRETE SLABS 4500 psi STD 0.45 6% - 8% (MAXIMUM SLUMP FOR EXTERIOR CONCRETE SHALL NOT EXCEED 4") E. ALL SLABS, TOPPINGS & FOOTINGS SHALL NOT HAVE JOINTS IN A HORIZONTAL PLANE. ANY STOP IN CONCRETE WORK SHALL BE MADE WITH VERTICAL BULKHEADS AND HORIZONTAL SHEAR KEYS UNLESS NOTED OTHERWISE. F. ALL CONCRETE WORK AND REINFORCEMENT DETAILING SHALL BE IN ACCORDANCE WITH ACI-318, LATEST EDITION, UNLESS NOTED OTHERWISE. 6. REINFORCEMENT A. ALL REINFORCING SHALL BE HIGH-STRENGTH DEFORMED BARS CONFORMING TO ASTM A615, GRADE 60 EXCEPT TIES WHICH SHALL BE ASTM, A615, GRADE 40 OR ASTM A706, GRADE 60. B. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185, GRADE 65 AND SHALL BE LAPPED ONE FULL MESH AND BE SECURELY WIRED TOGETHER AT SPLICES. C. MINIMUM CONCRETE COVER FOR REINFORCEMENT C1. CONCRETE CAST AGAINST EARTH 3" C2. CONCRETE CAST IN FORMS (EXPOSED TO EARTH/WEATHER) 1 1/2" D. REINFORCEMENT PLACEMENT AND TOLERANCES SHALL BE IN ACCORDANCE WITH ACI-318 LATEST EDITION. ALL REINFORCING SHALL BE ACCURATELY LOCATED, TIED IN PLACE AND SECURED AGAINST DISPLACEMENT PRIOR TO PLACING CONCRETE. E. NO SPLICES OF REINFORCEMENT SHALL BE MADE EXCEPT AS DETAILED OR AUTHORIZED BY THE STRUCTURAL ENGINEER. LAP SPLICES,WHERE PERMITTED, SHALL BE A MINIMUM OF 48 BAR DIAMETERS FOR #6 BARS AND SMALLER . 7. WOOD A. ALL FRAMING LUMBER SHALL BE DRY DOUGLAS-FIR LARCH GRADED BY WESTERN WOOD PRODUCTS ASSOCIATION AND CONFORMING TO THE INTERNATIONAL BUILDING CODE AS FOLLOWS: 2" TO 4" THICK / 6" AND WIDER #2 Fb = 900 PSI 2" TO 4" THICK / 6" AND WIDER #1 Fb = 1000 PSI 5" AND THICKER / 5" AND WIDER #1 Fb = 1350 PSI NOTED ALLOWABLE STRESSES ARE MINIMUMS AND FOR NON-REPETITIVE USES PRIOR TO ALLOWABLE STRESS INCREASES. B. WHEN PRESERVATIVE TREATED LUMBER IS USED, ALL METAL CONNECTORS AND NAILS SHALL BE GALVANIZED (DOUBLE-DIPPED OR BETTER). C. PROVIDE SOLID BLOCKING OR METAL CROSS BRIDGING AT NOT OVER 8'-0" SPACING FOR ALL 2X WOOD JOISTS WITHOUT RIGID CEILING APPLIED TO THE UNDERSIDE. PROVIDE SOLID FULL DEPTH BLOCKING AT ALL SUPPORTS AND AT ENDS OF CANTILEVERS. D. FASTEN ALL WOOD MEMBERS WITH COMMON NAILS AS PER IBC TABLE 2304.9.1 UNLESS NOTED OTHERWISE. JOIST HANGERS AND OTHER COLD FORMED METAL PLATE CONNECTORS SHALL HAVE FASTENERS AS REQUIRED BY MANUFACTURER'S SPECIFICATIONS. LAG SCREWS SHALL BE INSTALLED IN PRE-DRILLED HOLES WITH A DIAMETER BETWEEN 40% AND 60% OF THE LAG SHANK DIAMETER FOR THE THREADED PORTION AND AT THE FULL LAG SHANK DIAMETER FOR THE UNTHREADED PORTION. E. GLUE-LAMINATED BEAMS E1. ALL LAMINATED BEAMS SHALL BE FABRICATED OF CEDAR AT 12% MAXIMUM MOISTURE CONTENT IN ACCORDANCE WITH WCLIB. ALL SIZES SHOWN ARE NET SIZES. E2. LAMINATED MEMBERS SHALL BE DETAILED AND FABRICATED IN ACCORDANCE WITH THE STANDARD SPECIFICATIONS FOR THE DESIGN AND FABRICATION OF STRUCTURAL GLUE-LAMINATED TIMBER LATEST EDITION AS PUBLISHED BY AITC. E3. PROVIDE UNITS CONFORMING TO AITC 117, 20F-V12 FOR CONTINUOUS MEMBERS, CANTILEVERS AND COLUMNS AND 20F-V13 FOR SIMPLY SUPPORTED MEMBERS. ALL GLU-LAMS SHALL BE DESIGNED WITH ZERO CAMBER WITH THE TOP SURFACE CLEARLY STAMPED ON EACH MEMBER. F. PLYWOOD AND/OR ORIENTED STRAND BOARD SHEATHING F1. PANEL THICKNESS SHALL BE AS SHOWN ON THE DRAWING. APPLICATION SHALL BE IN ACCORDANCE WITH RECOMMENDATIONS OF THE AMERICAN PLYWOOD ASSOCIATION. F2. EACH PANEL SHALL BE IDENTIFIED WITH THE GRADE-TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIATION AND SHALL MEET THE REQUIREMENTS OF U.S. PRODUCTS STANDARD PSI, LATEST EDITION FOR PLYWOOD. ALL PANELS HAVING ANY SURFACE OR EDGE PERMANENTLY EXPOSED TO THE WEATHER SHALL BE OF THE EXTERIOR TYPE. F3. FOR SUB-FLOORING USED ON DECKS, USE 3/4" MARINE GRADE TONGUE AND GROOVE STURD-I-FLOOR SHEATHING GLUED WITH CONSTRUCTION ADHESIVE AND FASTENED WITH 10d NAILS AT 4" ALONG PANEL EDGES AND AT 12" LONG INTERMEDIATE SUPPORTS. PROVIDE ADEQUATE SLOPE AND 1/8" SPACE BETWEEN PANEL EDGES. CAULK JOINTS WITH FLEXIBLE SEALANT. F4. FLOOR SHEATHING SHALL BE INSTALLED WITH THE FACE GRAIN PERPENDICULAR TO SUPPORTS WITH END JOINTS STAGGERED. $7+.&+0)  &'%-5  56#+45 # 4'/1&'. (14 5#0&5610'  5  4'& 56#0&5610' 41#& 70+65 %  & 8#+. %1  05/04/17