HomeMy WebLinkAboutB17-0128_A1.0_1493920380.pdfDN
REPLACE EXISTING
ASPHALT DRIVEWAY WITH
NEW (HEATED) EXPOSED
AGGEREGATE CONCRETE
DRIVEWAY = 3515 S.F.
(CONTROL JOINTS IN
SLAB)
SLOPE
6424
SETBACK
REMOVE RAILING AND
REPLACE WITH CURB ONLY
MAX. DROP TO GRADE = 30"
ON NORTH SIDE
REMOVE EXISTING RIVER
ROCK VENEER ON DRIVE
RETAINING WALL AND
REPLACE WITH MATCHING
HOUSE VENEER
(COLORADO BUFF STRIP)
EXISTING PAVER WALKWAY TO BE REPLACED
WITH HEATED WALK PATH
NEW DRY CREEK BED WITH FRENCH DRAIN AND
RIP RAP ROCKS TO PARALLEL WALK AND BECOME
THE DRIVE WATER FLOW LINE - SEPARATING
WALK AND WATER FLOW
3 STEPS (7" RISE, 14"
TREAD) STONE ON
CONCRETE
NEW 12'X14' TERRACE STONE ON 4"
CONCRETE. RAMP UP GRADES AT
PERMETER. ADD LANDSCAPE BOULDERS
AND NEEDED. MAX 18" DROP OFF
TERRACE
APPROX. LOCATION OF
EXISTING TREES
TO REMAIN
REMOVE WOOD STAIRS
REMOVE AND REPLACE
WOOD DECKING WITH
NEW STONE FLAGSTONE
ON 4" CONCRETE SLAB
REMOVE EXISTING LANDING AND STAIR TO
DINING. EXISTING DINING ROOM DOOR TO BE
REPLACED WITH WINDOW UNIT.
NEW TERRACE TO BE ALL AT THE LOWER
LEVEL
(LIVING ROOM LEVEL)
REMOVE EXSTING WOOD
STAIR AND REPLACE WITH
RECTILINEAR STONE
COVERED CONCRETE STAIR
3' - 5"
NESPA ENTRERPRISES INC
10x8 LEGACY WITH AUTO COVER
ALL TILED SPA
(8-PERSON)
SMALL EXISTING DECORATIVE
TREE TO BE REMOVED
WOOD DECK TO BE REMOVED AND REPLACED WITH NEW STONE TERRACE/
STAIRS ON SIDE OF HOUSE TO BE
REMOVED AND REPLACED WITH
CONCRETE AND STONE STAIR
REMOVE RAILING AND
REPLACE WITH CURB ONLY
MAX. DROP TO GRADE = 30"
ON NORTH SIDE
REMOVE
SANDSET PAVERS
NEW TERRACE
AREA 220 S.F.
STONE PAVER COLOR (COLORADO BUFF)
Portion of heated driveway from property line to
concrete back of the concrete curb and gutter will
require to be heated on a separate zone and
marked at the control box, (roughly 10 ft or so.)
A Revocable Right of Way Permit will be applied
for during the permit application
4'-0" WIDE
CONCRETE PAN
AT STREET
PAIR OF FIXED UNITS
30x80. FEILD VERIFT EXACT DIMENSIONS
COLOR AND STYLE TO MATCH EXISTING
TEMPERED GLASS IN UNIT
7' - 6"7' - 6"
SPA
refer to landscaping drawing for
plantings
WRAP EXISTING WOOD
COLUMN WITH 3/4"
MATERIAL AND PAINT
WRAP EXISTING WOOD COLUMN WITH 3/4" MATERIAL AND PAINT
WRAP EXISTING WOOD COLUMN WITH 3/4" MATERIAL AND PAINT
4
A2.0
14' - 0" 7' - 0"
PROVIDE LANDSCAPE BOULDERS AS BACKDROP
4' - 9 1/2"
2' - 4" 11' - 6"
17' - 8"
16' - 4"
10' - 8" 8" 18' - 10"
8" PAVERS OVER BILCO ACCESS LID
CENTER SWALE TO DIRECT WATER
DRAINAGE TO DRY CREEK BED
QA
BUILD BOULDER
RETING WALL TO
PROTECT EXISTING
TREE
REMOVE EXISTING TREES
REMOVE EXISTING PLANTERS AT
FRONT OF HOUSE
PROVIDE NEW STONE
CLAD STEP AT FRONT
DOOR
60"
ELDORADO
STONE FIRE
VESSEL
STEP
LIGHT
STEP
LIGHT
STEPLIGHT
STEP LIGHT
BOLLARD
LIGHT
BOLLARD
LIGHT
BOLLARD
LIGHT
BOLLARD
LIGHT
BOLLARD
LIGHT
BOLLARD
LIGHT
BOLLARD
LIGHT
BOLLARD
LIGHT
BOLLARD
LIGHT
STEP LIGHT, EVERY 3RD STEP. PROVIDE EXTERIOR SWITCH AT BTM OF STAIR. TIE TO EXISTING SCONCES
R @7 1/4"
14
BOLLARD
LIGHT
BOLLARD
LIGHT
BOLLARD
LIGHT
BOLLARD
LIGHT
BOLLARD
LIGHT
BOLLARD
LIGHT
STEP
LIGHT
STEP
LIGHT
STEP
LIGHT
BOLLARD
LIGHT
STEP
LIGHT
15 landscape bollard lights
light source is darksky
light source is < 18" above grade
16 step lights
light source is darksky
light source is < 18" above grade
1/8" = 1'-0"
1
SITE PLAN PROJECT NORTH
970.328.5151
OFFICE
PO Box 1587,
Eagle, CO 81631
www.martinmanleyarchitects.com
Project
number
Date
REVISIONS
4/5/2017
8:31:21 AM
A1.0
SITE
PLAN
1622
GRIFFIS
RESIDENCE DRB
SET #3
04-05
-2017
Exterior
Deck and Patio
Renovation
Lot 20, Block 2, Vail Village
13th
Filing
2460
Bald
Mountain Rd
DOOR TO BE REPLACED WITH 48" WIDE AND 60"
DOUBLE CASEMENT WINDOWS (MATCH EXISTING
WINDOW COLOR) MATCH STUCCO AT REPAIR TO
WALL
STAIR TO DINING TO BE REMOVED
Existing Residencet
Owner: NORTH NORTH NEVADA LLC - ETAL
Owner Address 6400 S FIDDLERS GREEN CIR STE 1200
GREENWOOD VILLAGE, CO 80111-4953
Location: 002460 BALD MOUNTAIN RD
Subdivision: VAIL VILLAGE FILING 13
Block: 2 Lot: 20
Parcel # 2101-033-01-004
Class of Work: Exterior Sitework Renovation
Type of Construction: Type V-N
Type of Occupancy: R3
Levels: 1-Story + Basement
PROJECT INFORMATION
Architect: Jeff Manley - Martin Manley Architects
PO Box 1587
Eagle CO 81631
jeff@martinmanleyarchitects.com
970-328-1299
No. Description Date
1 Revision 1 Date 1
05/04/17