R-1 SECOND FLOOR MECHANICAL PLAN
1/4" = 1'-0"
1. REMOVE EXISTING CEILING MOUNTED EXHAUST FAN
(FIELD VERIFY LOCATION) AND REPLACE WITH NEW FAN,
AS SHOWN AND SPECIFIED. CONNECT NEW FAN TO
EXISTING SWITCHING AND DUCTWORK, AS REQUIRED.
2. ROUTE EXHAUST DUCT TO WALL MOUNTED EXTERIOR
VENT CAP.
3. SNOWMELT PIPING TO SNOWMELT MANIFOLD IN CLOSET
FROM SNOWMELT BOILER ON ROOF. SEE SHEET M2.03
FOR MORE INFORMATION.
4. MANUAL QUADRANT BALANCING DAMPER, TYPICAL.
5. ROUTE HUMIDIFIER BLOW DOWN DRAIN LINE TO
NEAREST AVAILABLE DRAIN SOURCE.
Mechanical Plan Notes:
CALLOUT USED FOR NOTE DESIGNATION
2
1
EF
4
EF
1
EF
2
EF
3
1
A
75-SG
12x6
A
75-SG
12x6
A 75-SG
12x6
H
1
SF
1
B
300-RG
12x12
3
3
SM-2
SM-3
12x6
12x6
12x6
12x6
12x8
12x10
12x10
4
6
5
GENERAL NOTES:
1. ALL SPIRAL ROUND DUCTWORK DIMENSIONS ARE INSIDE
TO INSIDE UNLESS NOTED OTHERWISE.
2. ALL RECTANGULAR DUCT SIZES ARE "OUT TO OUT". NO
ALLOWANCE IS REQUIRED FOR 1" INTERNAL LINING.
3. PROVIDE FULLY PROGRAMMABLE DIGITAL THERMOSTATS
FOR CONTROL OF FAN COILS. SEE THIS SHEET FOR FOR
LOCATIONS. COORDINATE FINAL
LOCATION WITH OWNER AND ARCHITECT.
4. MECHANICAL CONTRACTOR SHALL SIZE REFRIGERANT
LINES AS PER MANUFACTURER'S REGRIGERANT LINE
SIZING REQUIREMENTS, AND FINAL PIPING DISTRIBUTION.
5. ACCESS TO FAN COILS SHALL BE CAREFULLY
COORDINATED BETWEEN GENERAL CONTRACTOR AND
MECHANICAL CONTRACTOR.
S
S
4 7
R-1 SECOND FLOOR
MECHANICAL PLAN
M2.01
SHEET NUMBER:
DRAWN BY:
CHECKED BY:
PROJECT MANAGER:
SHEET TITLE:
SEAL:
NO. ISSUANCE DATE
PROJECT NUMBER: 51258
SCALE:
NO. DATE
of
1 LOT 15 BIGHORN SUBDIVIION
VAIL, CO 81657
Permit Set