HomeMy WebLinkAboutB17-0154_M0.1_1497476280.pdfA B B R E V I A T I O N S S Y M B O L S ( N O T A L L U S E D )
FITTINGS
VALVES MISCELLANEOUS
CAPPED OUTLET - SCREWED
CAPPED OUTLET - FLANGED
CAPPED OUTLET - WELDED
CONCENTRIC REDUCER
FLOW ORIFICE
NEW CONNECTION
NEW CONNECTION - ANGLED
NEW CONNECTION - INSERTION
PIPING CONNECTION - BOTTOM
PIPING CONNECTION - DOWN
PIPING CONNECTION - UP
UNION
STRAINER
BALL JOINT
EXPANSION JOINT
EXPANSION LOOP
F FILTER - IN LINE
3-WAY AUTOMATIC CONTROL VALVE
ALARM CHECK VALVE
ANGLE VALVE
AUTOMATIC BALL DRIP VALVE
PNEUMATIC AUTOMATIC CONTROL VALVE
BALANCING VALVE
BALL VALVE
BUTTERFLY VALVE
CHECK VALVE
GATE VALVE
CURB VALVE
DIAPHRAGM VALVE
DRY PIPE VALVE
M ELECTRIC MOTORIZED VALVE OPERATOR
FLOAT VALVE
FLOW CONTROL VALVE
GLOBE VALVE
LOCK SHIELD VALVE
M
ELECTRIC MOTORIZED VALVE
NEEDLE VALVE
OS&Y VALVE
OS&Y VALVE WITH TAMPER SWITCH
PEG VALVE
PLUG VALVE
P
PNEUMATIC MOTORIZED VALVE OPERATOR
POST INDICATOR
PRE-ACTION VALVE
PRESSURE REDUCING VALVE
QUICK CLOSING VALVE
QUICK OPENING VALVE
R RELIEF VALVE
S SAFETY VALVE
S
SOLENOID VALVE
S SILENT CHECK VALVE
STOP CHECK VALVE
VALVE IN VERTICAL
AIR VENT (AUTOMATIC)
AIR VENT (MANUAL)
A AQUASTAT
BFP BACK FLOW PREVENTER
BASKET STRAINER
CIRCULATOR PUMP
CV CONTROL VALVE STATION
DUPLEX BASKET STRAINER
FILTER
FS FLOW SWITCH
FLOW METER
HD HEAT DETECTOR
H HUMIDIFIER
H HUMIDISTAT
PIPE ALIGNMENT GUIDE
PIPE ANCHOR
? L/M/H PRESSURE DRIP ASSEMBLY
PSD PUMP SUCTION DIFFUSER
PRESSURE GAUGE
PRV PRESSURE REDUCING VALVE STATION
P PRESSURE SENSOR
PS PRESSURE SWITCH
REFRIGERANT SIGHT GLASS
SD SMOKE DETECTOR
S SEPARATOR
TT TEMPERATURE TRANSMITTER
THERMOMETER GAUGE
T THERMOSTAT
TRAP
VIBRATION ISOLATOR IN HANGER
BACK DRAFT DAMPER
ELECTRICAL DAMPER
AUTOMATIC DAMPER (PNEUMATIC)
VOLUME DAMPER
BDD
DAMPERS
SUPPLY
SUPPLY WITH NECK
SUPPLY WITH BLANKING PLATE
SUPPLY ROUND
SUPPLY ROUND WITH BLANKING PLATE
RETURN\EXHAUST WITH BLANKING PLATE
RETURN\EXHAUST ROUND
RETURN\EXHAUST WITH NECK
RETURN
DIFFUSERS
FIRE DAMPER AND ACCESS DOOR
AUTOMATIC DAMPER (MOTORIZED)
M
COMBINATION FIRE SMOKE DAMPER
RISE IN DUCTWORK (IN DIRECTION OF AIR FLOW)
DROP IN DUCTWORK (IN DIRECTION OF AIR FLOW)
R
D
LOUVER IN DOOR, MINIMUM 1.0 SQUARE FOOT FREE AREA
L
UNDERCUT DOOR
UC
1.0 SQ. F.A.
POINT OF CONNECTION
POINT OF DISCONNECTION
STEEL CUT
CLD-B
400 CFM.
12x12 CD
400 CFM.
CLD-A
400 CFM.
300 CFM.
10x8 CR (CG)
10"x6" TOP REGISTER
150 CFM. SUPPLY AIR
150 CFM.
10x6 TR
10"x6" TOP REGISTER (TOP GRILLE)
150 CFM. SUPPLY AIR
150 CFM.
10x6 TR (TG)
10"x6" BOTTOM REGISTER (BOTTOM GRILLE)
150 CFM. SUPPLY AIR
10x6 BOTR (BOTG)
150 CFM.
REMOVE EXISTING PIPING
EXISTING PIPING
ABANDON EXISTING PIPING
HEAT TRACING ON PIPE
FLEXIBLE HOSE
ECCENTRIC REDUCER
THERMOMETER AND WELL
SYPHON
THERMOMETER WELL
12"x12" NECK, 400 CFM SUPPLY AIR
RECTANGULAR CEILING DIFFUSER WITH
TYPA ACEILING DIFFUSER
400 CFM. SUPPLY AIR
400 CFM. SUPPLY AIR
TYPA B ROUND DIFFUSER
10"x8" CEILING REGISTER (CEILING GRILLE)
300 CFM. RETURN AIR
DASHED BOLD LINE WEIGHT ON DEMO PLAN INDICATES
EQUIPMENT ABBREVIATION (SEE ABBREVIATION LIST)
EQUIPMENT SCHEDULE NUMBER
NORTH ARROW
LETTER
ELEVATION IS DRAWN
SECTION OR ELEVATION IDENTIFICATION
DRAWING ON WHICH DETAIL IS DRAWN
DETAIL IDENTIFICATION NUMBER
DRAWING ON WHICH SECTION OR
LIGHT LINE WEIGHT INDICATES EXISTING WORK
SECTION OR DETAIL IDENTIFICATION
BOLD LINE WEIGHT INDICATES NEW WORK
MATCHLINE
REVISION
REVISION CLOUD
DRAWING REFERENCE NOTE
GENERAL
ID
ID
M-7
A
LABEL
LABEL
LABEL
LABEL
ID
FLEXIBLE PIPE CONNECTION
HOSE CONNECTION
CARBON DIOXIDE SENSOR
CO2
WORK TO BE REMOVED
TRASNSITION FITTING
FD
CFSD
EXHAUST
COMBINATION SHUT-OFF
BALANCING VALVE
RETURN\EXHAUST ROUND WITH
BLANKING PLATE
SHEET DESCRIPTION
MECHANICAL SHEET INDEX
SCALE
M0.1 MECHANICAL SYMBOLS, ABBREVIATIONS AND NOTES NTS
M0.2 MECHANICAL SPECIFICATIONS NTS
M0.3 MECHANICAL SPECIFICATIONS AND SCHEDULES NTS
M1.1 MECHANICAL DEMOLITION FLOOR PLAN - BACK OF HOUSE 1/4" = 1'-0"
M1.2 MECHANICAL DEMOLITION FLOOR PLAN - ACCOUNTING 1/4" = 1'-0"
M1.3 MECHANICAL DEMOLITION FLOOR PLAN - ARIA BACK OF HOUSE 1/4" = 1'-0"
M2.1 MECHANICAL NEW FLOOR PLAN - BACK OF HOUSE 1/4" = 1'-0"
M2.2 MECHANICAL NEW FLOOR PLAN - ACCOUNTING 1/4" = 1'-0"
M2.3 MECHANICAL NEW FLOOR PLAN - ARIA BACK OF HOUSE 1/4" = 1'-0"
HVAC GENERAL DEMOLITION NOTES
1. COMPLETED INSTALLATIONS SHALL CONFORM TO ALL APPLICABLE FEDERAL CODES, STATE AND LOCAL ORDINANCES AND THE SPECIFICATIONS. IF ANY CONFLICTS OCCUR, THE MOST STRINGENT SHALL APPLY.
2. PIPING AND DUCT LAYOUT IS ONLY SCHEMATIC, EXACT LOCATION OF PIPES AND DUCTS SHALL BE COORDINATED WITH BUILDING STRUCTURE, AND WORK OF OTHER CONTRACTORS PRIOR TO START OF ANY
CONSTRUCTION OR DEMOLITION.
3. EXISTING WORK SHOWN ON PLANS IS FROM PREVIOUS ENGINEERING DOCUMENTS AND FIELD OBSERVATION. ACTUAL CONDITIONS MAY VARY, AND CONTRACTOR MUST FIELD VERIFY EXISTING WORK. MAKE MINOR
ADJUSTMENTS NECESSARY TO COMPLETE WORK. IF EXISTING CONDITIONS PROHIBIT WORK, NOTIFY THE ARCHITECT FOR REDIRECTION AS REQUIRED.
4. THE CONTRACTOR IS RESPONSIBLE FOR ALL WARRANTIES ON THE EQUIPMENT INSTALLED.
5. INSURE THE EXECUTION OF ALL WARRANTIES FOR EQUIPMENT AND INSTALLATION AS PRESCRIBED BY THE OWNER.
6. ALL DUCTS AND PIPES ARE ABOVE CEILING AND TIGHT TO BOTTOM OF STRUCTURE UNLESS OTHERWISE NOTED.
7. ELEVATIONS, WHERE SHOWN, ARE CENTER OF PIPE AND BOTTOM OF DUCT UNLESS OTHERWISE NOTED.
8. COORDINATE SIZE AND LOCATION OF ALL RECESSES AND OPENINGS REQUIRED FOR HVAC WORK.
9. LOCATE ALL TEMPERATURE, PRESSURE AND FLOW MEASURING DEVICES IN ACCESSIBLE LOCATIONS WITH STRAIGHT SECTION OF PIPE OR DUCT UP OR DOWNSTREAM AS RECOMMENDED BY THE MANUFACTURER
FOR ACCURACY.
10. LOCATE ALL MECHANICAL EQUIPMENT FOR UNOBSTRUCTED ACCESS TO UNIT ACCESS PANELS, CONTROLS AND VALVING.
11. LOCATE ROOM THERMOSTATS, 4'-0" (CENTERLINE) ABOVE FINISHED FLOOR. NOTIFY ARCHITECT WHERE DIMENSION CANNOT BE MAINTAINED OR WHERE THERE IS A QUESTION ON LOCATION.
12. VERIFY CONDITION OF ALL EXISTING LIFE SAFETY DEVICES (FIRE DAMPERS, DUCT DETECTORS, ETC.) WITHIN LIMITS OF CONSTRUCTION. REPAIR OR REPLACE IF FOUND TO BE DAMAGED OR NON-FUNCTIONAL.
13. PROVIDE ALL DUCTWORK TRANSITIONS TO ACCOMMODATE ALL FIRE, FIRE / SMOKE DAMPER, FANS, AIR HANDLING UNITS & TERMINAL BOXES. REFER TO MANUFACTURER'S DATA FOR EQUIPMENT CONNECTION SIZES.
14. LOCATIONS OF FIRE AND FIRE/SMOKE DAMPERS ARE PROVIDED AS REQUIRED FOR DUCTWORK LAYOUT SHOWN. PROVIDE ADDITIONAL DAMPERS AS REQUIRED BY GOVERNING AUTHORITY AND AS REQUIRED SHOULD
DUCTWORK LAYOUT CHANGE AS A RESULT OF ACTUAL FIELD CONDITIONS.
15. CONTRACTOR SHALL COORDINATE THE ORDER IN WHICH EXISTING MECHANICAL EQUIPMENT IS REMOVED AND REPLACED WITH THE FACILITIES ENGINEERS.
16. WHEN ALL CONSTRUCTION IS COMPLETE, INSTALL NEW, CLEAN FILTERS IN AIR HANDLING UNITS SERVING THE RENOVATED AREAS. VERIFY CONDITION OF EXISTING FILTER GAUGES. REPAIR OR REPLACE IF FOUND TO
BE DAMAGED OR NON-FUNCTIONAL.
17. COORDINATE EXISTING LOCATIONS OF DIFFUSERS, GRILLES, ETC. WITH REFLECTED CEILING GRID AND LIGHTING LAYOUT.
18. PRIOR TO ROUGH IN, COORDINATE THE INSTALLATION OF EQUIPMENT WITH THE MANUFACTURES' INSTALLATION AND MAINTENANCE REQUIREMENTS.
19. CONTRACTOR SHALL PROVIDE TEMPORARY COOLING AS REQUIRED DURING CONSTRUCTION TO MAINTAIN ACCEPTABLE COMFORT LEVELS.
1. DEMOLITION SHALL EXTEND TO POINTS OF CONNECTION
WITH LIVE SERVICES, PANELBOARDS, OR OTHER APPLICABLE
TERMINATION POINTS. DEMOLITION SHALL NOT PERMIT
ABANDONMENT OF ANY SYSTEM OR A COMPONENT OF ANY
SYSTEM, UNLESS SPECIFICALLY NOTED AS "ABANDON" OR
"TO REMAIN".
2. DEMOLITION OF SYSTEMS SHALL INCLUDE UNITS, SUPPORT
SYSTEMS, SYSTEM ACCESSORIES, SYSTEM CONTROLS,
WIRING AND CONDUIT FOR POWER AND CONTROLS,
ASSOCIATED PIPING, DUCTWORK, SUPPORTS, ETC. IN THEIR
ENTIRETY, UNLESS SPECIFICALLY OTHERWISE NOTED.
3. ALL REMOVED EQUIPMENT SHALL BE MAINTAINED IN GOOD
CONDITION. REMOVED EQUIPMENT NOT INDICATED FOR
REUSE SHALL REMAIN THE PROPERTY OF THE OWNER.
SHOULD THE OWNER DECLINE POSSESSION OF ANY
EQUIPMENT, SAID EQUIPMENT SHALL BECOME THE
PROPERTY OF THE CONTRACTOR. THE CONTRACTOR SHALL
DELIVER ALL REMOVED EQUIPMENT TO THE OWNER. THE
CONTRACTOR SHALL BE REQUIRED TO REMOVE ALL
CONTRACTOR PROPERTY FROM THE SITE.
4. EXISTING INFORMATION SHOWN ON THE PLANS IS DERIVED
FROM ORIGINAL DESIGN AND MODIFICATION PLANS FOR THE
SITE MADE AVAILABLE TO THE ENGINEER. ADDITIONAL
UNDOCUMENTED MODIFICATIONS HAVE BEEN MADE AT THE
SITE. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION,
ROUTING, AND SIZES OF EXISTING DUCTWORK AND PIPING TO
REMAIN OR BE MODIFIED PRIOR TO BEGINNING ANY WORK.
CONTRACTOR SHALL REPORT ANY MAJOR DISCREPANCIES
TO THE ARCHITECT FOR RECOMMENDED ACTION.
1. RUN ALL DUCTS LEVEL UNLESS OTHERWISE NOTED.
2. DUCT SIZES SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. INSTALLED DIMENSIONS SHALL NOT BE SMALLER. INTERNAL LINER, WHERE ALLOWED, SHALL
NOT BE INSTALLED DOWNSTREAM OF FINAL FILTERS.
3. RUN OUT DUCT TO AIR DEVICES SHALL BE THE SAME SIZE AS THE AIR DEVICE NECK, UNLESS OTHERWISE NOTED. BALANCING DAMPERS ARE REQUIRED FOR ALL
INDIVIDUAL DEVICE CONNECTIONS. BALANCE DAMPERS SHALL BE LOCATED AT THE ORIGIN OF THE INDIVIDUAL BRANCH CONNECTION.
4. FLEXIBLE RUNOUTS TO DIFFUSERS AND GRILLES TO BE MAXIMUM OF 5 FEET IN LENGTH. FLEX SHALL BE STRETCHED STRAIGHT WITHOUT SAGS. PROVIDE HANGER
AT MID POINT. USE NYLON STRAP TO FASTEN INNER SLEEVE TO TAKE-OFF. DUCT TAPE IS NOT ACCEPTABLE.
5. DUCT TAPE IS NOT ACCEPTABLE FOR VAPOR BARRIER SEAMS.
6. OFFSET DUCTS INTO JOIST SPACE FOR CLEARANCE WHERE SPACE ABOVE CEILING IS NOT SUFFICIENT FOR DUCTS TO CROSS OTHER DUCTS OR WORK OF OTHER
CONTRACTORS.
7. INSTALL BALANCING DAMPERS AS SHOWN AND AS REQUIRED FOR PROPER BALANCING OF AIR HANDLING SYSTEMS.
1. INSTALL CONTROL DEVICES AS REQUIRED ON ALL UNITS. VERIFY ALL EQUIPMENT IS FUNCTIONAL AND PROPER BALANCE IS ACHIEVED BEFORE COMPLETION.
COORDINATE WITH OWNER'S REPRESENTATIVE ON EXISTING EQUIPMENT.
2. PROVIDE ALL CONTROLS AND CONTROLLERS, INCLUDING STARTERS AND CONTACTORS, NECESSARY FOR A COMPLETE AND OPERATIONAL HVAC SYSTEM. INCLUDE
ALL ELECTRICAL WORK NECESSARY TO COMPLY WITH THIS REQUIREMENT. COORDINATE POWER SOURCE CONNECTIONS PRIOR TO ORDERING EQUIPMENT OR
BEGINNING WORK.
3. COORDINATE THE VOLTAGE AND PHASE OF EACH PIECE OF EQUIPMENT WITH ALL TRADES BEFORE ORDERING.
HVAC GENERAL NOTES
GENERAL DUCTWORK
CONTROLS
VAIL
CASCADE + ARIA
RENOVATION
1300
WESTHAVEN
DRIVE
Vail, Colorado
04/20/2017
Revisions:
Sheet Title:
Project No:
Sheet No:
Issue Dates:
(970) 748-1470
email: tab@vail.net
fax: (970) 748-1471
Avon, CO 81620-7431
Post Office Box 7431
TAB
The Architectural Balance
Associates
www.tabassociates.com
Plotted:
4/19/2017
5:46:09 PM P:\DAL\BET\TABCO001\CAD\SHEETS\MECHANICAL\M0.1 MECHANICAL
SYMBOLS
ABBREVIATIONS AND NOTES.DWG - snahas
A member company of SH Group, Inc.
R
Syska Hennessy Group, Inc.
1130 E. Arapaho Road
Suite #525
Richardson, TX 75081
Tel: 972.470.0704
Fax: 972.470.5851
www.syska.com
MECH
SYMBOLS
ABBR AND
NOTES
M0.1
06/14/17