HomeMy WebLinkAboutB17-0154_P6.0_1497477794.pdfVAIL
CASCADE + ARIA
RENOVATION
1300
WESTHAVEN
DRIVE
Vail, Colorado
04/20/2017
Revisions:
Sheet Title:
Project No:
Sheet No:
Issue Dates:
(970) 748-1470
email: tab@vail.net
fax: (970) 748-1471
Avon, CO 81620-7431
Post Office Box 7431
TAB
The Architectural Balance
Associates
www.tabassociates.com
Plotted:
4/19/2017
6:14:30 PM P:\DAL\BET\TABCO001\CAD\SHEETS\PLUMBING\P6.0
PLUMBING
DETAILS.DWG - snahas
A member company of SH Group, Inc.
R
Syska Hennessy Group, Inc.
1130 E. Arapaho Road
Suite #525
Richardson, TX 75081
Tel: 972.470.0704
Fax: 972.470.5851
www.syska.com
& SCREW
CLEANOUT
WALL
FLOOR LINE
PLUGGED TEE W/
CHROME WALLCOVER
WASTE OR VENT
MAY EXTEND AS A
AS CLEANOUT TO GRADE.
BALANCE OF PIPING SAME
1/8"C.I. BEND
PIPE (TYP.)
INSULATION (TYP.)
AND SMALLER
FOR PIPE 2 1/2"
HANGER ROD
PIPE
INSULATION
H.W. PIPE 3" AND
PIPE ROLLER FOR
UNISTRUT CHANNEL
AND LARGER
LOCK NUTS(TYP.
FOR ALL SUPPORTS)
DOUBLE NUTS OR
FLAT WASHERS
SHIELD FOR PIPE 3"
FOR PIPE 2-1/2"
AND SMALLER
LARGER
PIPE CLAMP & SHIELD
HALF ROUND OR FULL ROUND
EXTEND 2" BEYOND
AND INSULATION SHALL
SINGLE PIPE RUNS
CLEVIS HANGER FOR
GALVANIZED IRON SHEET SHIELD
GALV. SHIELD EACH WAY.
INSULATION AT EACH HANGER
PROVIDE A SECTION OF HIGH
POINT. INSULATION MAY BE
COMPRESSION STRENGTH
SUPPORT
AT THIS
POINT
HUB JOINT
FINISHED FLOOR
FILL
"P" TRAP
DEEP SEAL
STRAINER
SCALE:
PIPING HANGERS AND SUPPORT DETAIL
N.T.S. 5 SCALE:
WALL CLEANOUT DETAIL
N.T.S. 6
SCALE:
FLOOR DRAIN DETAIL
N.T.S. 3
ABOVE UNIT FOR MAINTENANCE
1'-6" MINIMUM CLEARANCE
VALVE
BALL
TEST COCKS
BALL VALVE
BALL VALVE
STRAINER
ASSEMBLY
BACKFLOW PREVENTER
DISCHARGE TO FLOOR DRAIN
RELIEF VALVE OUTLET TO
FLOOR
FITTING
AIR GAP
BOTTOM FOR MAINTENANCE
2'-6" MINIMUM CLEARANCE AT
CLAMP CORNERS
AT 45° ANGLE
CHAMFER RISER
CONCRETE
FLOOR SLAB
PLAN VIEW
RISER
CLAMP
RISER
ELEVATION VIEW
IF REQUIRED
(SEE SPECS)
INSULATION
SLEEVE
SHEET METAL
GALVANIZED
1 1/2" STEEL
PIPE
MIN. 3"
STOP PLATE
1 1/4" ANCHOR AND WATER
WELD ALL AROUND
HOT DIP SLEEVE TO
REGALVANIZED AFTER
WELDING
BOLT AND NUT
PRESSURE PLATE
RUBBER SEALING
ELEMENT
PRESSURE
PLATE
CAULK WITH
LINK SEAL
SCHEDULE 40 GALV.
STEEL PIPE. SIZE
AS REQUIRED
( NON-INSULATED PIPE OR CONDUIT )
LINK SEAL
FIRE RESISTIVE
FOR FIRE RATED
WALLS PROVIDE
NOTE:
SCALE:
PIPE SLEEVE THRU WALL DETAIL
N.T.S.
1 SCALE:
TYPICAL FLOOR PENETRATION DETAIL
N.T.S. 2
SCALE:
REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER ASSEMBLY
N.T.S.
4
PLUMBING
DETAILS
P6.0
CW
DRAIN
WALL CLEAN OUT
CW
HW
CONNECTION TO COUNTER
TOP COFFEE MAKER
IN-LINE FILTER GE MODEL
GXRLQ OR APPROVED
EQUAL
LINE TO ICE MAKER
LINE TO WATER
DISPENSER
WATTS #LF05 MINI WATER
HAMMER ARRESTOR (TYP)
HOT AND COLD
WATER STOPS
PROVIDE ASSE 1022 COMPLIANT BACKFLOW
PREVENTER IN WATER LINE TO FILTER UNIT,
MODEL 009 RPZ BY WATTS VALVE
CORPORATION OR APPROVED EQUAL.
NOTE:
PROVIDE ELASTOMERIC INSULATION WITH PVC
COVERING SYSTEM ON ALL PIPING BELOW THE
SINK PER ADA REQUIREMENTS
ADA MOUNTED STAINLESS
STEEL SINK, FAUCET &
RELATED ACCESSORIES SEE
SPECIFICATIONS
SCALE:
BREAK SINK DETAIL
N.T.S.
7
WB-1
TRAP PRIMER WHEN REQUIRED
TRAP GUARD WHEN REQUIRED
06/14/17