Loading...
HomeMy WebLinkAboutB17-0154_P6.0_1497477794.pdfVAIL CASCADE + ARIA RENOVATION 1300 WESTHAVEN DRIVE Vail, Colorado 04/20/2017 Revisions: Sheet Title: Project No: Sheet No: Issue Dates: (970) 748-1470 email: tab@vail.net fax: (970) 748-1471 Avon, CO 81620-7431 Post Office Box 7431 TAB The Architectural Balance Associates www.tabassociates.com Plotted: 4/19/2017 6:14:30 PM P:\DAL\BET\TABCO001\CAD\SHEETS\PLUMBING\P6.0 PLUMBING DETAILS.DWG - snahas A member company of SH Group, Inc. R Syska Hennessy Group, Inc. 1130 E. Arapaho Road Suite #525 Richardson, TX 75081 Tel: 972.470.0704 Fax: 972.470.5851 www.syska.com & SCREW CLEANOUT WALL FLOOR LINE PLUGGED TEE W/ CHROME WALLCOVER WASTE OR VENT MAY EXTEND AS A AS CLEANOUT TO GRADE. BALANCE OF PIPING SAME 1/8"C.I. BEND PIPE (TYP.) INSULATION (TYP.) AND SMALLER FOR PIPE 2 1/2" HANGER ROD PIPE INSULATION H.W. PIPE 3" AND PIPE ROLLER FOR UNISTRUT CHANNEL AND LARGER LOCK NUTS(TYP. FOR ALL SUPPORTS) DOUBLE NUTS OR FLAT WASHERS SHIELD FOR PIPE 3" FOR PIPE 2-1/2" AND SMALLER LARGER PIPE CLAMP & SHIELD HALF ROUND OR FULL ROUND EXTEND 2" BEYOND AND INSULATION SHALL SINGLE PIPE RUNS CLEVIS HANGER FOR GALVANIZED IRON SHEET SHIELD GALV. SHIELD EACH WAY. INSULATION AT EACH HANGER PROVIDE A SECTION OF HIGH POINT. INSULATION MAY BE COMPRESSION STRENGTH SUPPORT AT THIS POINT HUB JOINT FINISHED FLOOR FILL "P" TRAP DEEP SEAL STRAINER SCALE: PIPING HANGERS AND SUPPORT DETAIL N.T.S. 5 SCALE: WALL CLEANOUT DETAIL N.T.S. 6 SCALE: FLOOR DRAIN DETAIL N.T.S. 3 ABOVE UNIT FOR MAINTENANCE 1'-6" MINIMUM CLEARANCE VALVE BALL TEST COCKS BALL VALVE BALL VALVE STRAINER ASSEMBLY BACKFLOW PREVENTER DISCHARGE TO FLOOR DRAIN RELIEF VALVE OUTLET TO FLOOR FITTING AIR GAP BOTTOM FOR MAINTENANCE 2'-6" MINIMUM CLEARANCE AT CLAMP CORNERS AT 45° ANGLE CHAMFER RISER CONCRETE FLOOR SLAB PLAN VIEW RISER CLAMP RISER ELEVATION VIEW IF REQUIRED (SEE SPECS) INSULATION SLEEVE SHEET METAL GALVANIZED 1 1/2" STEEL PIPE MIN. 3" STOP PLATE 1 1/4" ANCHOR AND WATER WELD ALL AROUND HOT DIP SLEEVE TO REGALVANIZED AFTER WELDING BOLT AND NUT PRESSURE PLATE RUBBER SEALING ELEMENT PRESSURE PLATE CAULK WITH LINK SEAL SCHEDULE 40 GALV. STEEL PIPE. SIZE AS REQUIRED ( NON-INSULATED PIPE OR CONDUIT ) LINK SEAL FIRE RESISTIVE FOR FIRE RATED WALLS PROVIDE NOTE: SCALE: PIPE SLEEVE THRU WALL DETAIL N.T.S. 1 SCALE: TYPICAL FLOOR PENETRATION DETAIL N.T.S. 2 SCALE: REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER ASSEMBLY N.T.S. 4 PLUMBING DETAILS P6.0 CW DRAIN WALL CLEAN OUT CW HW CONNECTION TO COUNTER TOP COFFEE MAKER IN-LINE FILTER GE MODEL GXRLQ OR APPROVED EQUAL LINE TO ICE MAKER LINE TO WATER DISPENSER WATTS #LF05 MINI WATER HAMMER ARRESTOR (TYP) HOT AND COLD WATER STOPS PROVIDE ASSE 1022 COMPLIANT BACKFLOW PREVENTER IN WATER LINE TO FILTER UNIT, MODEL 009 RPZ BY WATTS VALVE CORPORATION OR APPROVED EQUAL. NOTE: PROVIDE ELASTOMERIC INSULATION WITH PVC COVERING SYSTEM ON ALL PIPING BELOW THE SINK PER ADA REQUIREMENTS ADA MOUNTED STAINLESS STEEL SINK, FAUCET & RELATED ACCESSORIES SEE SPECIFICATIONS SCALE: BREAK SINK DETAIL N.T.S. 7 WB-1 TRAP PRIMER WHEN REQUIRED TRAP GUARD WHEN REQUIRED 06/14/17