Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B17-0179_14ACX_1496764816.pdf
AIR CONDITIONERS 14ACX MERIT® Series R-410A Bulletin No. 210740 April 2017 Supersedes March 2017 SEER up to 16.00 1.5 to 5 Tons Cooling Capacity - 17,900 to 59,000 Btuh 14 AC x – 024 - 230 A 02 Nominal SEER Unit Type AC = Air Conditioner Refrigerant X = R-410A Nominal Cooling Capacity 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 041 = 3.5 tons 042 = 3.5 tons 047 = 4 tons 048 = 4 tons 059 = 5 tons 060 = 5 tons Minor Revision Level Voltage 230 = 208/230V-1phase-60hz MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS Ratings Revision Level (NOTE - 018-024-030-036-042 models only) Regional Standards – (dash) = All Regions or Southwest Region (dependent on size) S = North and South Regions 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 2 WARRANTY Compressor - limited warranty for five years in residential installations and five years in non-residential installations. All other covered components - five years in residential installations and one year in non-residential installations. Note - Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPROVALS AHRI Certified to AHRI Standard 210/240-2008. Sound rated in Lennox reverberant sound test room in Accordance with test conditions included in AHRI Standard 270-2008. Tested in the Lennox Research Laboratory environmental test room. Rated According to U.S. Department of Energy (DOE) test procedures. Region specific models meet the minimum efficiency requirements for U.S DOE Federal Regional Standards in that area. Units and components within bonded for grounding to meet safety standards for servicing required by UL, NEC and CEC. Units are ETL certified for the U.S. and Canada. ISO 9001 Registered Manufacturing Quality System. For expanded ratings, see www.LennoxPROs.com. APPLICATIONS SEER up to 16.00. 1.5 through 5 ton. Single-phase power supply. Sound levels as low as 76 dB. Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Matching add-on furnace indoor coils or air handlers provide a wide range of cooling capacities and applications. See AHRI System Matches. See Indoor Coils and Air Handlers sections for data. Units shipped completely factory assembled, piped and wired. Each unit test operated at the factory ensuring proper operation. Installer must set air conditioner, connect refrigerant lines and make electrical connections to complete job. A B C D E F FEATURES CONTENTS AHRI System Matches - All Regions .........................14 AHRI System Matches - North / South Region.......... 51 AHRI System Matches - Southwest Region ............125 Dimensions - Unit ........................................................8 Electrical Data..............................................................6 Features.......................................................................2 Field Wiring.................................................................. 5 Installation Clearances ................................................5 Model Number Identification ........................................1 Optional Accessories ...................................................6 RFC Orifice Usage.....................................................10 Sound Data.................................................................. 9 Specifications...............................................................6 TXV Usage ..................................................................9 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 3 REFRIGERATION SYSTEM R-410A Refrigerant Non-chlorine, ozone friendly, R-410A. Unit pre-charged with refrigerant. See Specification table. Outdoor Coil Fan Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan motor has sleeve bearings (-018 through -048 and -060 models), ball bearings (-059 model) and is inherently protected. Motor totally enclosed for maximum protection from weather, dust and corrosion. Rain shield on motor provides additional protection from moisture. Louvered steel top fan guard furnished as standard. Fan service access accomplished by removal of top panel. Copper Tube/Enhanced Fin Coil Lennox designed and fabricated coil. Ripple-edged aluminum fins. Copper tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections/silver soldering construction. Coil is factory tested under high pressure to ensure leakproof construction. Steel louvered panels provide complete coil protection. Panels can be completely removed for servicing. High Capacity Liquid Line Drier Furnished with unit for field installation. Approved for use with R-410A systems. Traps any moisture or dirt that could contaminate the refrigerant system. High Pressure Switch Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting. Protects compressor from excessive condensing pressure. Manual reset. B C Refrigerant Flow Control Units applicable to expansion valve systems or RFC systems when matched with specific indoor coils. RFCIV: Accurately meters refrigerant in system. Refrigerant control is accomplished by exact sizing of refrigerant metering orifice. The principle involves matching indoor coil with proper bore size of orifice in metering device. Equalizes pressure shortly after compressor stops, unit starts unloaded, eliminating need for additional controls. See RFC Orifice Usage Table on Page 10 for correct matches. Optional Accessories Expansion Valve Kits Must be ordered extra and field installed on certain indoor units. See TXV Usage Table on Page 9. Chatleff-style fittings. Freezestat Installs on or near the vapor line of the indoor coil or on the suction line. Senses suction line temperature and cycles the compressor off when suction line temperature falls below it’s setpoint. Opens at 29°F and closes at 58°F. Loss of Charge Switch Kit Helps protect the compressor from damage due low refrigerant charge conditions. SPST, normally-closed switch, automatic reset switch mounted on liquid line. Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized and sealed at factory. Suction line fully insulated. Lines are stubbed at both ends. Not available for -059-060 models. Must be field fabricated. ORING RFCIV METERING SYSTEM RFCIV ORIFICE ORIFICE BODY (On Coil) SEAL NUT SWEAT CONNECTION LIQUID LINE LIQUID LINE SCREEN FEATURES 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 4 COMPRESSOR Scroll Compressor Compressor features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged. Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. Compressor is installed in the unit on resilient rubber mounts for vibration free operation. Compressor Crankcase Heater (-041, -047, -048, -059 & -060 Models) Protects against refrigerant migration that can occur during low ambient operation. Optional Accessories Compressor Crankcase Heater (Optional for 018- 024-030-036-042) Protects against refrigerant migration that can occur during low ambient operation. Compressor Sound Cover A reinforced vinyl compressor cover containing a 1-1/2 inch thick batt of fiberglass insulation. All open edges are sealed with a one-inch wide hook and loop fastening tape. D CONTROLS Optional Accessories Compressor Hard Start Kit Single-phase units are equipped with a PSC compressor motor. This type of motor normally doesn’t need a potential relay and start capacitor. In conditions such as low voltage, this kit may be required to increase the compressor starting torque. Compressor Low Ambient Cut-Off Switch Non-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 35°F. Compressor Time-Off Control Kit prevents compressor short-cycling and allows time for suction and discharge pressure to equalize. Permits compressor start-up in an unloaded condition. Automatic reset with 5 minute delay between compressor shut-off and start-up. Indoor Blower Off Delay Relay Delays the indoor blower-off time during the cooling cycle. See AHRI System Matches for usage. Low Ambient Kit Air conditioners operate satisfactorily in the cooling mode down to 45°F outdoor air temperature without any additional controls. Kit can be added in the field enabling unit to operate properly down to 30°F in the cooling mode. Crankcase heater and freezestat should be installed on compressors equipped with a Low Ambient Kit. A compressor lock-out thermostat should be added to terminate compressor operation below recommended operation conditions. Thermostat Thermostat not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book. FEATURES 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 5 CABINET Heavy gauge steel cabinet with five station metal wash process. Louvered heavy gauge steel panels surround unit on all four sides to prevent damage to the coil. Powder paint finish provides superior rust and corrosion protection. Control box is conveniently located with all controls factory wired. Corner patch plate allows access to compressor components. Drainage holes are provided in base section for moisture removal. PermaGuard™ Unit Base Durable zinc-coated base section resists rust and corrosion. Refrigerant Line Connections, Electrical Inlets, Service Valves Sweat connection suction and liquid lines are located on corner of unit cabinet. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system. Refrigerant line connections and field wiring inlets are located in one central area of cabinet for easy access. See dimension drawing. E F B DISCONNECT SWITCH (By Others) LENNOX AIR CONDITIONER LENNOX HEATING UNIT OR AIR HANDLER UNIT DISCONNECT SWITCH (By Others) THERMOSTAT (Optional) C D A See NOTES See NOTES See NOTES See NOTES CONTROL BOX A - Two Wire Power B - Two Wire Power (See Electrical Data) C - Two Wire Low Voltage (18 ga. minimum) D - Four Wire Low Voltage (Electro-Mechanical) 18 ga. minimum. Five Wire Low Voltage (Electronic) 18 ga. minimum NOTE - Field Wiring Not Furnished All wiring must conform to NEC or CEC and local electrical codes. NOTES: Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 36 in. (914 mm) Clearance to one of the remaining two sides may be 12 in. (305 mm) and the final side may be 6 in. (152 mm). A clearance of 24 in. must be maintained between two units. 48 in. (1219 mm) clearance required on top of unit. Optional Accessories Unit Stand-Off Kit Black high density polyethylene feet are available to raise unit off of mounting surface away from damaging moisture. Four feet are furnished per order number. FEATURES FIELD WIRING INSTALLATION CLEARANCES - IN. (MM) 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 6 SPECIFICATIONS General Data Model No. All Regions - - - - - - - - - - - - 14ACX-041 North / South Regions 14ACXS018 14ACXS024 14ACXS030 14ACXS036 - - - Southwest Region 14ACX-018 14ACX-024 14ACX-030 14ACX-036 - - - Nominal Tonnage 1.5 2 2.5 3 3.5 Connections (sweat) Liquid line o.d. - in. 3/8 3/8 3/8 3/8 3/8 Suction line o.d. - in. 3/4 3/4 3/4 7/8 7/8 1 Refrigerant (R-410A) furnished 4 lbs. 13 oz. 5 lbs. 6 oz. 6 lbs. 11 oz. 6 lbs. 11 oz. 10 lbs. 1 oz. Outdoor Coil Net face area sq. ft. Outer coil 13.22 16 21 21 21 Inner coil - - - - - - - - - - - - 20.25 Tube diameter - in. 5/16 5/16 5/16 5/16 5/16 Number of rows 1 1 1 1 2 Fins per inch 26 26 26 26 22 Outdoor Fan Diameter - in. 18 22 22 22 22 Number of blades 3 3 3 3 4 Motor hp 1/10 1/6 1/6 1/6 1/4 Cfm 2290 3160 3160 3160 3600 Rpm 1075 825 825 825 825 Watts 160 215 215 215 310 Shipping Data - lbs. 1 package 138 158 171 177 209 ELECTRICAL DATA Line voltage data - 60 hz - 1ph 208/230V 208/230V 208/230V 208/230V 208/230V 2 Maximum overcurrent protection (amps) 20 25 25 30 35 3 Minimum circuit ampacity 12.4 15.0 17.1 18.6 22.6 Compressor Rated load amps 9.4 11.2 12.9 14.1 16.7 Locked rotor amps 56.6 60.8 64 77 79 Power factor 0.96 0.97 0.98 0.98 0.97 Condenser Fan Motor Full load amps 0.7 1.0 1.0 1.0 1.7 Locked rotor amps 1.3 1.9 1.9 1.9 3.2 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 • • • • Factory • Compressor Hard Start Kit 10J42 • • 88M91 • • • Compressor Low Ambient Cut-Off Switch 45F08 • • • • • Compressor Sound Cover 27W55 • • • • 27W56 • Compressor Time-Off Control 47J27 • • • • • Freezestat 3/8 in. tubing 93G35 • • • • • 5/8 in. tubing 50A93 • • • • • Indoor Blower Off Delay Relay 58M81 • • • • • Loss of Charge Switch Kit 84M23 • • • • • 4 Low Ambient Kit (Fan Cycling) 34M72 • • • • • Refrigerant Line Sets L15-41-20, L15-41-30, L15-41-40, L15-41-50 • • • L15-65-30, L15-65-40, L15-65-50 • • Unit Stand-Off Kit 94J45 • • • • • NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. 1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 2 HACR type circuit breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 7 SPECIFICATIONS General Data Model No. All Regions - - - 14ACX-047 14ACX-048 14ACX-059 14ACX-060 North / South Regions 14ACXS042 - - - - - - - - - - - - Southwest Region 14ACX-042 - - - - - - - - - - - - Nominal Tonnage 3.5 4 4 5 5 Connections (sweat) Liquid line o.d. - in. 3/8 3/8 3/8 3/8 3/8 Suction line o.d. - in. 7/8 7/8 7/8 1-1/8 1-1/8 1 Refrigerant (R-410A) furnished 8 lbs. 10 oz. 11 lbs. 3 oz. 10 lbs. 8 oz. 11 lbs. 2 oz. 12 lbs. 0 oz. Outdoor Coil Net face area sq. ft. Outer coil 18.67 22 21 24.94 22 Inner coil 17.96 21.33 20.25 24.14 21.33 Tube diameter - in. 5/16 5/16 5/16 5/16 5/16 Number of rows 2 2 2 2 2 Fins per inch 22 22 22 22 22 Outdoor Fan Diameter - in. 22 26 22 26 26 Number of blades 4 4 4 4 4 Motor hp 1/4 1/3 1/4 1/3 1/3 Cfm 3500 4400 3600 4400 4400 Rpm 825 825 825 825 825 Watts 310 310 310 310 310 Shipping Data - lbs. 1 package 208 250 228 266 253 ELECTRICAL DATA Line voltage data - 60 hz - 1ph 208/230V 208/230V 208/230V 208/230V 208/230V 2 Maximum overcurrent protection (amps) 40 45 45 50 60 3 Minimum circuit ampacity 24.1 26.7 26.7 34.1 34.8 Compressor Rated load amps 17.9 19.9 20 25 26.4 Locked rotor amps 112 109 99 134 134 Power factor 0.94 0.97 0.99 0.98 0.98 Condenser Fan Motor Full load amps 1.7 1.8 1.7 2.8 1.8 Locked rotor amps 3.2 2.9 3.2 - - - 2.9 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 • Factory • • • • Compressor Hard Start Kit 88M91 • • • • • Compressor Low Ambient Cut-Off Switch 45F08 • • • • • Compressor Sound Cover 27W56 • • • • • Compressor Time-Off Control 47J27 • • • • • Freezestat 3/8 in. tubing 93G35 • • • • • 5/8 in. tubing 50A93 • • • • • Indoor Blower Off Delay Relay 58M81 • • • • • Loss of Charge Switch Kit 84M23 • • • • • 4 Low Ambient Kit (Fan Cycling) 34M72 • • • • 68M04 • Refrigerant Line Sets L15-65-30, L15-65-40, L15-65-50 • • • Field Fabricate • • Unit Stand-Off Kit 94J45 • • • • • NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. 1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 2 HACR type circuit breaker or fuse. 3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 8 SUCTION AND C SIDE VIEW DISCHARGE AIR SIDE VIEW A B A LIQUID LINE CONNECTION OUTDOOR COIL FAN COMPRESSOR OPTIONAL UNIT STANDOFF KIT (4) (FIELD INSTALLED) 4-3/8 INLET AIR INLET AIR TOP VIEW INLET AIR INLET AIR SUCTION LINE CONNECTION LIQUID LINE CONNECTION 6-3/8 (162) TOP VIEW BASE SECTION COMPRESSOR COIL DRAIN OUTLETS (Around perimeter of base) OPTIONAL UNIT STAND-OFF KIT (4) (Field Installed) (111) 4-3/8 4-3/8 4-3/8 4-3/8 6-3/8 (162) (111) (111) (111 111) 4-3/8 (111) 2 (51) 3/4 (19) 2-3/4 (70) ELECTRICAL INLETS Model A B C inches mm inches mm inches mm 018 24-1/4 616 29-1/4 743 28-1/2 724 024 28-1/4 718 29-1/4 743 28-1/2 724 030 28-1/4 718 37-1/4 946 36-1/2 927 036 28-1/4 718 37-1/4 946 36-1/2 927 041 28-1/4 718 37-1/4 946 36-1/2 927 042 28-1/4 718 33-1/4 845 32-1/2 826 047 32-1/4 817 33-1/4 845 32-1/2 826 048 28-1/4 718 37-1/4 946 36-1/2 927 059 32-1/4 817 37-1/4 946 36-1/2 927 060 32-1/4 817 33-1/4 845 32-1/2 826 DIMENSIONS - UNIT - INCHES (MM) 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 9 SOUND DATA 1 Unit Model Octave Band Linear Sound Power Levels dB, re 10-12 Watts Center Frequency - HZ 1 Sound Rating Number (dB) 125 250 500 1000 2000 4000 8000 018 69.5 70.5 71.0 71.0 69.0 63.5 57.5 76 024 69.5 72.0 70.5 70.5 67.5 62.5 57.5 76 030 72.5 74.0 74.0 72.0 67.5 61.5 56.5 76 036 73.5 75.0 74.0 72.5 67.5 62.5 56.5 76 041 76.5 74.0 73.5 73.5 70.0 62.5 58.5 78 042 73.5 75.5 74.5 73.5 70.5 64.0 58.5 78 047 76.5 77.5 77.5 73.5 69.0 63.5 60.5 80 048 76.5 74.0 73.5 73.5 70.0 62.5 58.5 78 059 79.5 76.5 76.5 72.5 68.0 63.0 60.5 78 060 76.5 77.5 77.5 73.5 69.0 63.5 60.5 80 NOTE - the octave sound power data does not include tonal correction. 1 Tested according to AHRI Standard 270-2008 test conditions. AHRI STANDARD 210/240 Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation. Units which do not have an indoor air-circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 1250 Btu/h per 1,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated. TXV USAGE Use this table for C33, C35, CH23, CH33, CH35 and CR33 Field Installed TXV Match-Ups. Outdoor Unit Model No. Thermal Expansion Valve (TXV) 14ACX(-)(S)018 12J18 14ACX(-)(S)024 12J18 14ACX(-)(S)030 12J18 14ACX(-)(S)036 12J19 14ACX-041 12J20 14ACX(-)(S)042 12J20 14ACX-047 12J20 14ACX-048 12J20 14ACX-059 12J20 14ACX-060 12J20 CX34 and CX35 upflow coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed. If a change out is required it will be listed in the “TXV SUBSTITUTIONS” table. The correct TXV must be ordered separately and field installed. C33, C35 and CH33 and CH35 coils - Replace the factory installed orifice with the expansion valve listed . CR33 and CH23 coils - Use the expansion valve listed. MOST POPULAR MATCHES Outdoor Unit Model No. Indoor Unit Model No 14ACX(-)(S)018 CX34-25 14ACX(-)(S)024 CX34-25 14ACX(-)(S)030 CX34-31 14ACX(-)(S)036 CX34-38 14ACX-041 CX34-49 14ACX(-)(S)042 CX34-49 14ACX-047 CX34-62C 14ACX-048 CX34-62C 14ACX-059 CX34-62C 14ACX-060 CX34-62C *TXV SUBSTITUTIONS Use this table to determine if the factory installed TXV in the indoor unit needs to be replaced. Outdoor Unit Model No. Indoor Coil Factory TXV Replacement TXV 14ACX(-)(S)030 CX34-42 12J20 12J18 14ACX(-)(S)030 CX34-43 12J20 12J18 14ACX(-)(S)030 CX35-48 12J20 12J18 14ACX(-)(S)036 CX34-31 12J18 12J19 * CX34 and CX35 coils - The factory installed expansion valve must be replaced with the expansion valve listed (ordered separately). If the combination is not listed above, the factory installed TXV is used. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 10 RFC ORIFICE USAGE (NORTH/SOUTH REGIONS) LEGEND: ◄ Green = Matches Orifice Furnished With Indoor Coil (no replacement necessary) ▲ Yellow = Matches Orifice Furnished With Outdoor Unit (orifice must be field replaced) Blue = Field Provided (must be ordered extra for field replacement) C33 COILS Indoor Coil Model No. Factory Orifice Furnished in Coil Outdoor Unit Model No. - Orifice Furnished With Outdoor Unit 14ACXS018 14ACXS024 14ACXS030 14ACXS036 14ACXS042 0.053 0.060 0.067 0.071 0.083 C33-19A-2 0.051 0.060 ▲ C33-25A-2 0.057 0.053 ▲ 0.060 ▲ 0.067 ▲ C33-25B-2 0.057 0.053 ▲ 0.060 ▲ 0.067 ▲ C33-31A-2 0.065 0.053 ▲ 0.060 ▲ 0.067 ▲ 0.071 ▲ C33-31B-2 0.065 0.053 ▲ 0.060 ▲ 0.067 ▲ 0.071 ▲ C33-36A-2 0.073 0.060 ▲ C33-36B-2 0.073 0.060 ▲ C33-36C-2 0.073 0.060 ▲ C33-38A-2 0.073 0.060 ▲ 0.067 ▲ 0.071 ▲ C33-38B-2 0.073 0.060 ▲ 0.067 ▲ 0.071 ▲ C33-43B-2 0.076 0.067 ▲ 0.071 ▲ C33-43C-2 0.076 0.067 ▲ 0.071 ▲ C33-48B-2 0.082 0.071 ▲ C33-48C-2 0.082 0.071 ▲ C33-49C-2 0.082 0.071 ▲ 0.083 ▲ C33-50/60C-2 0.082 0.071 ▲ C33-62C-2 0.093 0.083 ▲ C35 COILS Indoor Coil Model No. Factory Orifice Furnished in Coil Outdoor Unit Model No. - Orifice Furnished With Outdoor Unit 14ACXS018 14ACXS024 14ACXS030 14ACXS036 14ACXS042 0.053 0.060 0.067 0.071 0.083 C35-18A/24-2F 0.053 ◄ 0.053 C35-18/24B-2F 0.053 ◄ 0.053 C35-24A-2F 0.057 0.053 ▲ ◄ 0.057 0.063 C35-24B-2F 0.057 0.053 ▲ ◄ 0.057 0.063 C35-30A-2F 0.067 0.057 ◄ 0.067 0.071 ▲ C35-30B-2F 0.067 0.057 ◄ 0.067 0.071 ▲ C35-30/36A-2F 0,057 ◄ 0.057 C35-30/36B-2F 0,057 ◄ 0.057 C35-30/36C-2F 0,057 ◄ 0.057 C35-36A-2F 0.070 0.057 0.065 ◄ 0.070 C35-36B-2F 0.070 0.057 0.065 ◄ 0.070 C35-48B-2F 0.071 0.063 ◄ 0.071 C35-48C-2F 0.071 0.063 ◄ 0.071 C35-49C-2F 0.076 0.070 0.077 C35-50/60C-2F 0.070 ◄ 0.070 C35-60D-2F 0.077 ◄ 0.077 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 11 RFC ORIFICE USAGE (NORTH/SOUTH REGIONS) LEGEND: ◄ Green = Matches Orifice Furnished With Indoor Coil (no replacement necessary) ▲ Yellow = Matches Orifice Furnished With Outdoor Unit (orifice must be field replaced) CH23, CH33, CR33 COILS Indoor Coil Model No. Factory Orifice Furnished in Coil Outdoor Unit Model No. - Orifice Furnished With Outdoor Unit 14ACXS018 14ACXS024 14ACXS030 14ACXS036 14ACXS042 0.053 0.060 0.067 0.071 0.083 CH23-41-2 N/A 0.060 ▲ CH33-25A 0.062 0.053 ▲ 0.060 ▲ 0.067 ▲ CH33-25B 0.062 0.060 ▲ CH33-31A 0.071 0.053 ▲ 0.060 ▲ 0.067 ▲ CH33-31B 0.071 0.067 ▲ ◄ 0.071 CH33-36A 0.076 0.060 ▲ CH33-36C 0.076 0.067 ▲ CH33-42B 0.082 0.060 ▲ 0.067 ▲ CH33-43B 0.082 0.060 ▲ 0.067 ▲ 0.071 ▲ 0.083 ▲ CH33-43C 0.082 0.083 ▲ CH33-44/48B 0.082 0.071 ▲ CH33-48 0.091 0.071 ▲ CH33-49 0.091 0.071 ▲ 0.083 ▲ CH33-50/60C 0.091 0.071 ▲ 0.083 ▲ CR33-30/36A,B,C N/A 0.053 ▲ 0.060 ▲ 0.067 ▲ CR33-48B,C N/A 0.071 ▲ CH35-36A N/A 0.060 ▲ CH35-36B N/A 0.060 ▲ CH35-36C N/A 0.060 ▲ 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 12 RFC ORIFICE USAGE (SOUTHWEST REGION) LEGEND: ◄ Green = Matches Orifice Furnished With Indoor Coil (no replacement necessary) ▲ Yellow = Matches Orifice Furnished With Outdoor Unit (orifice must be field replaced) Blue = Field Provided (must be ordered extra for field replacement) NOTE - 14ACX-041-047-048-059-060 Models are only matched with TXVs. C33 COILS Indoor Coil Model No. Factory Orifice Furnished in Coil Outdoor Unit Model No. - Orifice Furnished With Outdoor Unit 14ACX-018 14ACX-024 14ACX-030 14ACX-036 14ACX-042 0.053 0.060 0.067 0.071 0.083 C33-31A-2 0.065 0.053 ▲ 0.060 ▲ 0.067 ▲ C33-31B-2 0.065 0.053 ▲ 0.060 ▲ 0.067 ▲ C33-38A-2 0.073 0.067 ▲ C33-38B-2 0.073 0.060 ▲ 0.067 ▲ C33-43B-2 0.076 0.067 ▲ 0.071 ▲ C33-43C-2 0.076 0.067 ▲ 0.071 ▲ C33-49C-2 0.082 0.071 ▲ C33-50/60C-2 0.082 0.071 ▲ C33-62C-2 0.093 0.083 ▲ C35 COILS Indoor Coil Model No. Factory Orifice Furnished in Coil Outdoor Unit Model No. - Orifice Furnished With Outdoor Unit 14ACX-018 14ACX-024 14ACX-030 14ACX-036 14ACX-042 0.053 0.060 0.067 0.071 0.083 C35-18/24A-2F 0.053 ◄ 0.053 C35-18/24B-2F 0.053 ◄ 0.053 C35-24A-2F 0.057 ◄ 0.057 C35-30A-2F 0.067 0.057 ◄ 0.067 C35-30B-2F 0.067 0.057 ◄ 0.067 C35-36A-2F 0.070 0.057 0.065 C35-36B-2F 0.070 0.057 0.065 C35-48B-2F 0.071 0.063 C35-48C-2F 0.071 0.063 C35-49C-2F 0.076 0.070 0.077 C35-50/60C-2F 0.070 ◄ 0.070 C35-60D-2F 0.077 ◄ 0.077 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 13 RFC ORIFICE USAGE (SOUTHWEST REGION) LEGEND: ◄ Green = Matches Orifice Furnished With Indoor Coil (no replacement necessary) ▲ Yellow = Matches Orifice Furnished With Outdoor Unit (orifice must be field replaced) NOTE - 14ACX-041-047-048-059-060 Models are only matched with TXVs. CH23, CH33, CR33 COILS Indoor Coil Model No. Factory Orifice Furnished in Coil Outdoor Unit Model No. - Orifice Furnished With Outdoor Unit 14ACX-018 14ACX-024 14ACX-030 14ACX-036 14ACX-042 0.053 0.060 0.067 0.071 0.083 CH33-25A 0.062 0.060 ▲ CH33-25B 0.062 0.060 ▲ CH33-31A 0.071 0.053 ▲ 0.060 ▲ 0.067 ▲ CH33-31B 0.071 0.053 ▲ 0.060 ▲ 0.067 ▲ ◄ 0.071 CH33-36C 0.076 0.060 ▲ CH33-42B 0.082 0.060 ▲ 0.067 ▲ CH33-43B 0.082 0.060 ▲ 0.067 ▲ 0.071 ▲ CH33-43C 0.082 0.083 ▲ CH33-44/48B 0.082 0.071 ▲ CH33-48 0.091 0.071 ▲ CH33-49 0.091 0.071 ▲ 0.083 ▲ CH33-50/60C 0.091 0.071 ▲ 0.083 ▲ CR33-30/36A,B,C N/A 0.053 ▲ 0.060 ▲ CH35-36A N/A 0.060 ▲ CH35-36B N/A 0.060 ▲ RFC ORIFICE ORDERING Orifice Size Order No. 0.053 97M74 0.057 97M75 0.060 10W97 0.063 97M76 0.065 10W99 0.067 11W00 0.070 98M13 0.071 10W85 0.077 11W03 0.083 11W07 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 14 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-041-230 TXV 38,500 15.50 13.20 C33-38 EL180UH090E48B 5735107 14ACX-041-230 TXV 38,500 15.50 13.20 C33-38 EL180UH090XE48B 5737071 14ACX-041-230 TXV 37,000 14.70 12.70 C33-42 EL180UH090E48B 5735136 14ACX-041-230 TXV 37,000 14.70 12.70 C33-42 EL180UH090XE48B 5737122 14ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL180UH090E48B 5735109 14ACX-041-230 TXV 39,000 16.00 13.50 C33-43 EL180UH090E60C 5736008 14ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL180UH090XE48B 5737073 14ACX-041-230 TXV 39,000 16.00 13.50 C33-43 EL180UH110E60C 5737832 14ACX-041-230 TXV 39,000 16.00 13.50 C33-43 EL180UH110XE60C 5738903 14ACX-041-230 TXV 39,000 15.70 13.50 C33-43 EL195UH090XE48C 4693850 14ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL195UH110XE60C 4693864 14ACX-041-230 TXV 39,000 15.70 13.50 C33-43 EL296UH090XE48C 5647286 14ACX-041-230 TXV 39,000 15.50 13.20 C33-43 EL296UH110XE60C 5647249 14ACX-041-230 TXV 39,000 15.70 13.50 C33-43 EL296UH110XV48C 5685129 14ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH090V60C 3869093 14ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH090XV60C 4235235 14ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH110V60C 3869094 14ACX-041-230 TXV 39,000 16.00 13.00 C33-43 SL280UH110XV60C 4040070 14ACX-041-230 TXV 38,000 15.20 13.00 C33-48 EL180UH090E48B 5735111 14ACX-041-230 TXV 38,500 15.50 13.20 C33-48 EL180UH090E60C 5736010 14ACX-041-230 TXV 38,000 15.20 13.00 C33-48 EL180UH090XE48B 5737074 14ACX-041-230 TXV 38,000 15.50 13.20 C33-48 EL180UH110E60C 5737834 14ACX-041-230 TXV 38,000 15.50 13.20 C33-48 EL180UH110XE60C 5738904 14ACX-041-230 TXV 37,800 15.20 13.00 C33-48 EL195UH090XE48C 4693851 14ACX-041-230 TXV 38,500 15.20 13.20 C33-48 EL195UH110XE60C 4693865 14ACX-041-230 TXV 37,800 15.20 13.00 C33-48 EL296UH090XE48C 5647236 14ACX-041-230 TXV 38,500 15.20 13.20 C33-48 EL296UH110XE60C 5647250 14ACX-041-230 TXV 38,500 15.20 13.20 C33-48 EL296UH110XV48C 5685130 14ACX-041-230 TXV 39,500 16.00 13.00 C33-49 EL180UH090E60C 5736012 14ACX-041-230 TXV 39,500 16.00 13.00 C33-49 EL180UH110E60C 5737836 14ACX-041-230 TXV 39,500 16.00 13.00 C33-49 EL180UH110XE60C 5738912 14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL195UH090XE48C 4693852 14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL195UH110XE60C 4693866 14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL296UH090XE48C 5647237 14ACX-041-230 TXV 39,500 15.50 12.50 C33-49 EL296UH090XV48C 7492822 14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL296UH110XE60C 5647251 14ACX-041-230 TXV 39,500 16.00 13.50 C33-49 EL296UH110XV48C 5685131 14ACX-041-230 TXV 38,500 14.50 12.50 C33-49 3869096 14ACX-041-230 TXV 38,500 15.70 13.20 C33-50/60C EL180UH090E60C 5736014 14ACX-041-230 TXV 38,500 15.70 13.20 C33-50/60C EL180UH110E60C 5737838 14ACX-041-230 TXV 38,500 15.70 13.20 C33-50/60C EL180UH110XE60C 5738915 14ACX-041-230 TXV 38,500 15.50 13.20 C33-50/60C EL195UH090XE48C 4693853 14ACX-041-230 TXV 38,500 15.50 13.00 C33-50/60C EL195UH110XE60C 4693867 14ACX-041-230 TXV 38,500 15.50 13.20 C33-50/60C EL296UH090XE48C 5647238 14ACX-041-230 TXV 38,500 15.50 13.00 C33-50/60C EL296UH110XE60C 5647252 14ACX-041-230 TXV 38,500 15.50 13.20 C33-50/60C EL296UH110XV48C 5685132 14ACX-041-230 TXV 40,000 16.00 13.00 C33-62C EL180UH090E60C 5736016 14ACX-041-230 TXV 40,000 16.00 13.00 C33-62C EL180UH110E60C 5737839 14ACX-041-230 TXV 40,000 16.00 13.00 C33-62C EL180UH110XE60C 5738916 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 15 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-041-230 TXV 40,000 16.00 13.50 C33-62C EL195UH090XE48C 4693854 14ACX-041-230 TXV 40,500 16.00 13.50 C33-62C EL195UH110XE60C 4693868 14ACX-041-230 TXV 40,000 16.00 13.50 C33-62C EL296UH090XE48C 5647239 14ACX-041-230 TXV 40,500 16.00 13.50 C33-62C EL296UH110XE60C 5647253 14ACX-041-230 TXV 40,000 16.00 13.00 C33-62C SLP98UH090XV48C 5767289 14ACX-041-230 TXV 38,500 15.50 12.50 C35-36B EL180UH090E48B 8267933 14ACX-041-230 TXV 38,500 15.50 12.50 C35-36B EL180UH090XE48B 8267932 14ACX-041-230 TXV 38,500 15.50 12.50 C35-48B EL180UH090E48B 8267940 14ACX-041-230 TXV 38,500 15.50 12.50 C35-48B EL180UH090XE48B 8267938 14ACX-041-230 TXV 37,800 14.50 12.20 C35-48B 8267934 14ACX-041-230 TXV 38,500 16.00 13.00 C35-48C EL180UH090E60C 8267939 14ACX-041-230 TXV 38,500 16.00 13.00 C35-48C EL180UH110E60C 8267941 14ACX-041-230 TXV 38,500 16.00 13.00 C35-48C EL180UH110XE60C 8267942 14ACX-041-230 TXV 38,500 15.50 12.50 C35-48C EL195UH090XE48C 8267946 14ACX-041-230 TXV 38,500 15.50 12.50 C35-48C EL195UH110XE60C 8267945 14ACX-041-230 TXV 38,500 15.50 12.50 C35-48C EL296UH090XE48C 8267944 14ACX-041-230 TXV 38,500 15.50 12.50 C35-48C EL296UH110XE60C 8267943 14ACX-041-230 TXV 39,000 16.00 13.00 C35-48C SL280UH090V60C 8267936 14ACX-041-230 TXV 39,000 16.00 13.00 C35-48C SL280UH090XV60C 8267947 14ACX-041-230 TXV 38,500 15.50 12.50 C35-48C SL280UH110V60C 8267937 14ACX-041-230 TXV 38,500 15.50 12.50 C35-48C SL280UH110XV60C 8267948 14ACX-041-230 TXV 37,800 14.50 12.20 C35-48C 8267935 14ACX-041-230 TXV 39,000 16.00 13.00 C35-49C EL180UH090E60C 8267950 14ACX-041-230 TXV 39,000 16.00 13.00 C35-49C EL180UH110E60C 8267951 14ACX-041-230 TXV 39,000 16.00 13.00 C35-49C EL180UH110XE60C 8267952 14ACX-041-230 TXV 38,500 16.00 13.00 C35-49C EL195UH090XE48C 8267956 14ACX-041-230 TXV 39,000 15.50 12.50 C35-49C EL195UH110XE60C 8267955 14ACX-041-230 TXV 38,500 16.00 13.00 C35-49C EL296UH090XE48C 8267954 14ACX-041-230 TXV 39,000 15.50 12.50 C35-49C EL296UH110XE60C 8267953 14ACX-041-230 TXV 38,500 14.70 12.50 C35-49C 8267949 14ACX-041-230 TXV 38,000 15.50 12.50 C35-50/60C EL180UH090E60C 8267957 14ACX-041-230 TXV 38,000 15.50 12.50 C35-50/60C EL180UH110E60C 8267958 14ACX-041-230 TXV 38,000 15.50 12.50 C35-50/60C EL180UH110XE60C 8267959 14ACX-041-230 TXV 38,000 15.50 12.50 C35-50/60C EL195UH090XE48C 8267963 14ACX-041-230 TXV 38,500 15.50 12.50 C35-50/60C EL195UH110XE60C 8267962 14ACX-041-230 TXV 38,000 15.50 12.50 C35-50/60C EL296UH090XE48C 8267961 14ACX-041-230 TXV 38,500 15.50 12.50 C35-50/60C EL296UH110XE60C 8267960 14ACX-041-230 TXV 40,000 16.00 13.00 C35-60C EL180UH090E60C 8267965 14ACX-041-230 TXV 40,000 16.00 13.00 C35-60C EL180UH110E60C 8267966 14ACX-041-230 TXV 40,000 16.00 13.00 C35-60C EL180UH110XE60C 8267967 14ACX-041-230 TXV 39,500 16.00 13.00 C35-60C EL195UH090XE48C 8267971 14ACX-041-230 TXV 40,000 16.00 13.00 C35-60C EL195UH110XE60C 8267970 14ACX-041-230 TXV 39,500 16.00 13.00 C35-60C EL296UH090XE48C 8267969 14ACX-041-230 TXV 40,000 16.00 13.00 C35-60C EL296UH110XE60C 8267968 14ACX-041-230 TXV 40,000 16.00 13.00 C35-60C SLP98UH090XV48C 8267964 14ACX-041-230 TXV 39,500 16.00 13.00 CBA27UHE-048 10259379 14ACX-041-230 TXV 38,000 14.50 12.50 CBX25UH-042 5732787 14ACX-041-230 TXV 39,500 15.20 13.00 CBX25UH-048 5732788 14ACX-041-230 TXV 39,000 16.00 13.50 CBX25UHV-042 6970129 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 16 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-041-230 TXV 40,000 16.00 14.00 CBX25UHV-048 6970130 14ACX-041-230 TXV 39,000 16.00 13.00 CBX27UH-048 3869097 14ACX-041-230 TXV 39,500 16.00 13.00 CBX32MV-048 3869098 14ACX-041-230 TXV 39,000 16.00 13.00 CBX40UHV-048 3869099 14ACX-041-230 TXV 37,600 15.50 13.00 CH23-51 EL180UH090E60C 5736596 14ACX-041-230 TXV 37,400 15.20 13.00 CH23-51 EL296UH110XV48C 5685140 14ACX-041-230 TXV 37,200 15.50 13.00 CH23-51 SL280UH090V60C 5514080 14ACX-041-230 TXV 38,000 15.50 13.00 CH23-65 EL180UH090E60C 5736598 14ACX-041-230 TXV 37,600 15.50 13.00 CH23-65 SL280UH090V60C 5514082 14ACX-041-230 TXV 39,500 16.00 13.50 CH33-43 EL180UH090E48B 5735097 14ACX-041-230 TXV 39,000 16.00 13.50 CH33-43 EL180UH090E60C 5735991 14ACX-041-230 TXV 39,500 16.00 13.50 CH33-43 EL180UH090XE48B 5737061 14ACX-041-230 TXV 39,000 16.00 13.50 CH33-43 EL180UH110E60C 5737813 14ACX-041-230 TXV 39,000 16.00 13.50 CH33-43 EL180UH110XE60C 5738874 14ACX-041-230 TXV 39,000 15.00 12.70 CH33-43 EL296UH045XV36B 5153070 14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 EL296UH090XV36C 5057187 14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 EL296UH090XV48C 5057188 14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 EL296UH090XV60C 5057189 14ACX-041-230 TXV 38,500 16.00 13.00 CH33-43 EL296UH110XV60C 5057190 14ACX-041-230 TXV 39,500 15.70 13.00 CH33-43 SL280UH090V36B 4253795 14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 SLP98UH090XV36C 5140458 14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 SLP98UH090XV48C 5140459 14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43 SLP98UH090XV60C 5140460 14ACX-041-230 TXV 38,500 16.00 13.00 CH33-43 SLP98UH110XV60C 5140461 14ACX-041-230 TXV 39,500 15.70 13.00 CH33-43B SL280UH090V48B 3869100 14ACX-041-230 TXV 39,500 15.70 13.00 CH33-43B SL280UH090XV48B 4038521 14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43C EL195UH090XE48C 4693855 14ACX-041-230 TXV 38,500 15.70 13.00 CH33-43C EL195UH110XE60C 4694030 14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43C EL296UH090XE48C 5647240 14ACX-041-230 TXV 38,500 15.70 13.00 CH33-43C EL296UH110XE60C 5647288 14ACX-041-230 TXV 39,000 15.70 13.50 CH33-43C EL296UH110XV48C 5685137 14ACX-041-230 TXV 39,500 16.00 13.00 CH33-43C SL280UH090V60C 3869104 14ACX-041-230 TXV 39,500 16.00 13.00 CH33-43C SL280UH090XV60C 4235236 14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43C SL280UH110V60C 3869105 14ACX-041-230 TXV 39,000 15.70 13.00 CH33-43C SL280UH110XV60C 4040073 14ACX-041-230 TXV 38,500 15.50 13.20 CH33-44/48 EL180UH090E48B 5735098 14ACX-041-230 TXV 38,500 15.50 13.20 CH33-44/48 EL180UH090XE48B 5737063 14ACX-041-230 TXV 38,000 14.70 12.50 CH33-44/48 EL296UH045XV36B 5153071 14ACX-041-230 TXV 38,500 15.70 13.20 CH33-48 EL180UH090E60C 5735993 14ACX-041-230 TXV 38,500 15.70 13.20 CH33-48 EL180UH110E60C 5737815 14ACX-041-230 TXV 38,500 15.70 13.20 CH33-48 EL180UH110XE60C 5738875 14ACX-041-230 TXV 38,500 15.20 13.00 CH33-48 EL296UH090XV36C 5057191 14ACX-041-230 TXV 38,500 15.50 13.00 CH33-48 EL296UH090XV48C 5057192 14ACX-041-230 TXV 38,500 15.20 13.00 CH33-48 SLP98UH090XV36C 5140515 14ACX-041-230 TXV 38,500 15.50 13.00 CH33-48 SLP98UH090XV48C 5140516 14ACX-041-230 TXV 38,500 15.50 13.00 CH33-48C EL195UH090XE48C 4693856 14ACX-041-230 TXV 39,000 15.50 13.20 CH33-48C EL195UH110XE60C 4693869 14ACX-041-230 TXV 38,500 15.50 13.00 CH33-48C EL296UH090XE48C 5647241 14ACX-041-230 TXV 39,000 15.50 13.20 CH33-48C EL296UH110XE60C 5647254 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 17 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-041-230 TXV 39,000 15.50 13.20 CH33-48C EL296UH110XV48C 5685138 14ACX-041-230 TXV 39,500 16.00 13.50 CH33-49 EL180UH090E60C 5735995 14ACX-041-230 TXV 39,500 16.00 13.50 CH33-49 EL180UH110E60C 5737818 14ACX-041-230 TXV 39,500 16.00 13.50 CH33-49 EL180UH110XE60C 5738877 14ACX-041-230 TXV 39,000 15.70 13.50 CH33-49 EL195UH090XE48C 4693857 14ACX-041-230 TXV 39,500 15.70 13.50 CH33-49 EL195UH110XE60C 4693870 14ACX-041-230 TXV 39,000 15.70 13.50 CH33-49 EL296UH090XE48C 5647242 14ACX-041-230 TXV 39,500 15.70 13.50 CH33-49 EL296UH110XE60C 5647255 14ACX-041-230 TXV 39,000 15.70 13.50 CH33-50/60C EL180UH090E60C 5795750 14ACX-041-230 TXV 39,000 15.70 13.50 CH33-50/60C EL180UH110E60C 5737820 14ACX-041-230 TXV 39,000 15.70 13.50 CH33-50/60C EL180UH110XE60C 5738879 14ACX-041-230 TXV 39,000 15.70 13.50 CH33-50/60C EL195UH090XE48C 4693858 14ACX-041-230 TXV 39,500 15.70 13.50 CH33-50/60C EL195UH110XE60C 4693871 14ACX-041-230 TXV 39,000 15.70 13.50 CH33-50/60C EL296UH090XE48C 5647243 14ACX-041-230 TXV 39,500 15.70 13.50 CH33-50/60C EL296UH110XE60C 5647256 14ACX-041-230 TXV 39,500 15.70 13.50 CH33-50/60C EL296UH110XV48C 5685139 14ACX-041-230 TXV 39,000 14.50 12.50 CH33-50/60C 4253798 14ACX-041-230 TXV 39,500 16.00 13.00 CH35-42B EL180UH090E48B 7163353 14ACX-041-230 TXV 39,000 15.10 13.00 CH35-42B EL296UH045XV36B 9973355 14ACX-041-230 TXV 39,500 15.50 13.00 CH35-42B SL280UH090V36B 7163354 14ACX-041-230 TXV 39,500 15.50 13.00 CH35-42B SL280UH090V48B 7163355 14ACX-041-230 TXV 39,000 15.10 13.00 CH35-42B SLP98UH070XV36B 7163356 14ACX-041-230 TXV 39,000 14.50 12.50 CH35-42B 7163350 14ACX-041-230 TXV 39,000 16.00 13.00 CH35-42C EL180UH090E60C 7163364 14ACX-041-230 TXV 39,000 16.00 13.00 CH35-42C EL180UH110E60C 7163365 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-42C EL195UH090XE48C 7163357 14ACX-041-230 TXV 39,000 15.50 13.00 CH35-42C EL195UH110XE60C 7164138 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-42C EL296UH090XE48C 7163361 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-42C EL296UH090XV36C 7163358 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-42C EL296UH090XV48C 7163359 14ACX-041-230 TXV 39,000 15.50 13.00 CH35-42C EL296UH090XV60C 7163360 14ACX-041-230 TXV 39,000 15.50 13.00 CH35-42C EL296UH110XE60C 7164140 14ACX-041-230 TXV 39,000 15.50 13.00 CH35-42C EL296UH110XV48C 7163362 14ACX-041-230 TXV 39,000 16.00 13.00 CH35-42C EL296UH110XV60C 7163363 14ACX-041-230 TXV 39,000 16.00 13.00 CH35-42C SL280UH090V60C 7163367 14ACX-041-230 TXV 39,000 15.50 13.00 CH35-42C SL280UH110V60C 7163368 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-42C SLP98UH090XV36C 7163369 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-42C SLP98UH090XV48C 7163370 14ACX-041-230 TXV 39,000 15.50 13.00 CH35-42C SLP98UH090XV60C 7163371 14ACX-041-230 TXV 38,500 16.00 13.00 CH35-42C SLP98UH110XV60C 7163372 14ACX-041-230 TXV 38,500 14.50 12.50 CH35-42C 7163351 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-48B EL180UH090E48B 7163376 14ACX-041-230 TXV 38,000 14.50 12.50 CH35-48B EL296UH045XV36B 9973356 14ACX-041-230 TXV 38,000 14.50 12.50 CH35-48B 7163373 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C EL180UH090E60C 7163383 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C EL180UH110E60C 7163384 14ACX-041-230 TXV 38,000 15.50 13.00 CH35-48C EL195UH090XE48C 7163377 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C EL195UH110XE60C 7163378 14ACX-041-230 TXV 38,500 15.10 13.00 CH35-48C EL296UH090XV36C 7163379 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 18 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C EL296UH090XV48C 7163380 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C EL296UH110XE60C 7163382 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C EL296UH110XV48C 7163381 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C SL280UH090V60C 7163385 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C SL280UH110V60C 7163386 14ACX-041-230 TXV 38,500 15.10 13.00 CH35-48C SLP98UH090XV36C 7163387 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C SLP98UH090XV48C 7163388 14ACX-041-230 TXV 38,500 15.10 13.00 CH35-48C SLP98UH090XV60C 7164139 14ACX-041-230 TXV 38,500 15.50 13.00 CH35-48C SLP98UH110XV60C 7163389 14ACX-041-230 TXV 38,000 14.50 12.50 CH35-48C 7163374 14ACX-041-230 TXV 39,000 16.00 13.00 CH35-51C EL180UH090E60C 7163396 14ACX-041-230 TXV 39,000 16.00 13.00 CH35-51C EL180UH110E60C 7163397 14ACX-041-230 TXV 39,000 15.50 13.00 CH35-51C EL195UH090XE48C 7163391 14ACX-041-230 TXV 39,000 15.50 13.00 CH35-51C EL195UH110XE60C 7163392 14ACX-041-230 TXV 39,000 15.50 13.00 CH35-51C EL296UH090XE48C 7163393 14ACX-041-230 TXV 39,000 15.50 13.00 CH35-51C EL296UH110XE60C 7163395 14ACX-041-230 TXV 39,500 15.50 13.00 CH35-51C EL296UH110XV48C 7163394 14ACX-041-230 TXV 39,000 15.50 13.00 CH35-51C SLP98UH090XV36C 7163398 14ACX-041-230 TXV 39,000 15.50 13.00 CH35-51C SLP98UH090XV48C 7163399 14ACX-041-230 TXV 39,500 15.50 13.00 CH35-51C SLP98UH090XV60C 7163400 14ACX-041-230 TXV 39,500 15.50 13.00 CH35-51C SLP98UH110XV60C 7163401 14ACX-041-230 TXV 38,500 14.50 12.50 CH35-51C 7163390 14ACX-041-230 TXV 38,500 15.70 13.50 CR33-50/60 EL180DF110E60C 5733505 14ACX-041-230 TXV 38,000 15.50 13.00 CR33-50/60 EL195DF090XE48C 4693849 14ACX-041-230 TXV 38,500 15.50 13.20 CR33-50/60 EL195DF110XE60C 4694029 14ACX-041-230 TXV 38,000 15.50 13.00 CR33-50/60 EL296DF090XE48C 5647285 14ACX-041-230 TXV 36,400 15.50 13.00 CR33-50/60 EL296DF090XV60C 5530488 14ACX-041-230 TXV 38,500 15.50 13.20 CR33-50/60 EL296DF110XE60C 5647287 14ACX-041-230 TXV 38,500 15.00 12.50 CR33-50/60 EL296DF110XV60C 7176680 14ACX-041-230 TXV 38,500 16.00 13.00 CR33-50/60 SL280DF090V60C 3869114 14ACX-041-230 TXV 39,000 16.00 13.00 CR33-50/60 SL280DF110V60C 3869166 14ACX-041-230 TXV 38,500 15.50 13.20 CX34-38 EL180UH090E48B 5735101 14ACX-041-230 TXV 38,500 15.50 13.20 CX34-38 EL180UH090XE48B 5737065 14ACX-041-230 TXV 38,000 14.70 12.50 CX34-38 EL296UH045XV36B 5153066 14ACX-041-230 TXV 37,000 14.70 12.70 CX34-42 EL180UH090E48B 5735135 14ACX-041-230 TXV 37,000 14.70 12.70 CX34-42 EL180UH090XE48B 5737120 14ACX-041-230 TXV 39,000 15.50 13.20 CX34-43 EL180UH090E48B 5735102 14ACX-041-230 TXV 39,000 16.00 13.50 CX34-43 EL180UH090E60C 5735998 14ACX-041-230 TXV 39,000 15.50 13.20 CX34-43 EL180UH090XE48B 5737067 14ACX-041-230 TXV 39,000 16.00 13.50 CX34-43 EL180UH110E60C 5737822 14ACX-041-230 TXV 39,000 16.00 13.50 CX34-43 EL180UH110XE60C 5738880 14ACX-041-230 TXV 39,000 15.70 13.00 CX34-43 EL195UH090XE48C 4693859 14ACX-041-230 TXV 38,500 15.50 13.00 CX34-43 EL195UH110XE60C 4693872 14ACX-041-230 TXV 38,500 14.70 12.70 CX34-43 EL296UH045XV36B 5153068 14ACX-041-230 TXV 39,000 15.70 13.00 CX34-43 EL296UH090XE48C 5647244 14ACX-041-230 TXV 38,500 15.50 13.00 CX34-43 EL296UH090XV36C 5057183 14ACX-041-230 TXV 39,000 15.70 13.00 CX34-43 EL296UH090XV48C 5057184 14ACX-041-230 TXV 39,000 15.50 13.00 CX34-43 EL296UH090XV60C 5057185 14ACX-041-230 TXV 38,500 15.50 13.00 CX34-43 EL296UH110XE60C 5647257 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 19 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-041-230 TXV 39,000 15.70 13.50 CX34-43 EL296UH110XV48C 5685133 14ACX-041-230 TXV 38,500 16.00 13.50 CX34-43 EL296UH110XV60C 5057186 14ACX-041-230 TXV 39,000 16.00 13.00 CX34-43 SL280UH090V60C 3869118 14ACX-041-230 TXV 39,000 16.00 13.00 CX34-43 SL280UH090XV60C 4235237 14ACX-041-230 TXV 39,000 16.00 13.00 CX34-43 SL280UH110V60C 3869119 14ACX-041-230 TXV 39,000 16.00 13.00 CX34-43 SL280UH110XV60C 4040077 14ACX-041-230 TXV 38,500 15.50 13.00 CX34-43 SLP98UH090XV36C 5140454 14ACX-041-230 TXV 39,000 15.70 13.00 CX34-43 SLP98UH090XV48C 5140455 14ACX-041-230 TXV 39,000 15.50 13.00 CX34-43 SLP98UH090XV60C 5140456 14ACX-041-230 TXV 38,500 16.00 13.50 CX34-43 SLP98UH110XV60C 5140457 14ACX-041-230 TXV 38,000 15.20 13.00 CX34-44/48 EL180UH090E48B 5735105 14ACX-041-230 TXV 38,500 15.50 13.20 CX34-44/48 EL180UH090E60C 5735999 14ACX-041-230 TXV 38,000 15.20 13.00 CX34-44/48 EL180UH090XE48B 5737069 14ACX-041-230 TXV 38,000 15.50 13.20 CX34-44/48 EL180UH110E60C 5737823 14ACX-041-230 TXV 38,000 15.50 13.20 CX34-44/48 EL180UH110XE60C 5738895 14ACX-041-230 TXV 37,800 15.20 13.00 CX34-44/48 EL195UH090XE48C 4693860 14ACX-041-230 TXV 38,500 15.20 13.20 CX34-44/48 EL195UH110XE60C 4693873 14ACX-041-230 TXV 37,800 14.50 12.50 CX34-44/48 EL296UH045XV36B 5153069 14ACX-041-230 TXV 37,800 15.20 13.00 CX34-44/48 EL296UH090XE48C 5647245 14ACX-041-230 TXV 38,500 15.20 13.20 CX34-44/48 EL296UH110XE60C 5647258 14ACX-041-230 TXV 38,500 15.20 13.20 CX34-44/48 EL296UH110XV48C 5685134 14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL180UH090E60C 5736001 14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL180UH110E60C 5737825 14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL180UH110XE60C 5738896 14ACX-041-230 TXV 39,500 16.00 13.50 CX34-49 EL195UH090XE48C 4693861 14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL195UH110XE60C 4693874 14ACX-041-230 TXV 39,500 16.00 13.50 CX34-49 EL296UH090XE48C 5647246 14ACX-041-230 TXV 39,500 15.50 12.50 CX34-49 EL296UH090XV48C 7492823 14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL296UH110XE60C 5647259 14ACX-041-230 TXV 39,500 16.00 13.50 CX34-49 EL296UH110XV48C 5685135 14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 EL296UH110XV60C 5057193 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-49 SL280UH090V60C 4253799 14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 SL280UH110V60C 4253800 14ACX-041-230 TXV 39,500 16.00 13.00 CX34-49 SLP98UH110XV60C 5140517 14ACX-041-230 TXV 39,000 14.50 12.50 CX34-49 3869121 14ACX-041-230 TXV 38,500 15.70 13.20 CX34-50/60C EL180UH090E60C 5736004 14ACX-041-230 TXV 38,500 15.70 13.20 CX34-50/60C EL180UH110E60C 5737828 14ACX-041-230 TXV 38,500 15.70 13.20 CX34-50/60C EL180UH110XE60C 5738899 14ACX-041-230 TXV 38,500 15.50 13.20 CX34-50/60C EL195UH090XE48C 4693862 14ACX-041-230 TXV 38,500 15.50 13.00 CX34-50/60C EL195UH110XE60C 4693875 14ACX-041-230 TXV 38,500 15.50 13.20 CX34-50/60C EL296UH090XE48C 5647247 14ACX-041-230 TXV 38,500 15.50 13.00 CX34-50/60C EL296UH110XE60C 5647260 14ACX-041-230 TXV 38,500 15.50 13.20 CX34-50/60C EL296UH110XV48C 5685136 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL180UH090E60C 5736006 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL180UH110E60C 5737830 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL180UH110XE60C 5738900 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL195UH090XE48C 4693863 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL195UH110XE60C 4693876 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL296UH090XE48C 5647248 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 20 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL296UH090XV36C 5057194 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL296UH090XV48C 5057195 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL296UH090XV60C 5057196 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL296UH110XE60C 5647261 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C EL296UH110XV60C 5057197 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C SL280UH090V60C 4253802 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C SL280UH110V60C 4253803 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C SLP98UH090XV36C 5140518 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C SLP98UH090XV48C 5140519 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C SLP98UH090XV60C 5140520 14ACX-041-230 TXV 40,000 16.00 13.00 CX34-62C SLP98UH110XV60C 5140521 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-36B EL180UH090E48B 8267973 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-36B EL180UH090XE48B 8267972 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48B EL180UH090E48B 8267978 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48B EL180UH090XE48B 8267976 14ACX-041-230 TXV 38,000 14.50 12.20 CX35-48B 8267974 14ACX-041-230 TXV 38,500 16.00 13.00 CX35-48C EL180UH090E60C 8267977 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL180UH110E60C 8267979 14ACX-041-230 TXV 38,500 16.00 13.00 CX35-48C EL180UH110XE60C 8267980 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL195UH090XE48C 8267992 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL195UH110XE60C 8267991 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL296UH090XE48C 8267982 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL296UH090XV36C 8267987 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL296UH090XV48C 8267988 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL296UH090XV60C 8267989 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL296UH110XE60C 8267981 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C EL296UH110XV60C 8267990 14ACX-041-230 TXV 39,000 16.00 13.00 CX35-48C SL280UH090V60C 8267995 14ACX-041-230 TXV 39,000 16.00 13.00 CX35-48C SL280UH090XV60C 8267994 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C SL280UH110V60C 8267996 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C SL280UH110XV60C 8267993 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C SLP98UH090XV36C 8267984 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C SLP98UH090XV48C 8267985 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-48C SLP98UH090XV60C 8267986 14ACX-041-230 TXV 38,000 16.00 13.00 CX35-48C SLP98UH110XV60C 8267983 14ACX-041-230 TXV 38,000 14.50 12.20 CX35-48C 8267975 14ACX-041-230 TXV 39,000 16.00 13.00 CX35-49C EL180UH090E60C 8267999 14ACX-041-230 TXV 39,000 16.00 13.00 CX35-49C EL180UH110E60C 8268000 14ACX-041-230 TXV 39,000 16.00 13.00 CX35-49C EL180UH110XE60C 8268001 14ACX-041-230 TXV 38,500 16.00 13.00 CX35-49C EL195UH090XE48C 8268006 14ACX-041-230 TXV 39,000 15.50 12.50 CX35-49C EL195UH110XE60C 8268007 14ACX-041-230 TXV 38,500 16.00 13.00 CX35-49C EL296UH090XE48C 8268002 14ACX-041-230 TXV 39,000 15.50 12.50 CX35-49C EL296UH090XV48C 8267998 14ACX-041-230 TXV 39,000 15.50 12.50 CX35-49C EL296UH110XE60C 8268003 14ACX-041-230 TXV 39,500 16.00 13.00 CX35-49C EL296UH110XV60C 8268005 14ACX-041-230 TXV 39,000 16.00 13.00 CX35-49C SL280UH090V60C 8268008 14ACX-041-230 TXV 39,000 16.00 13.00 CX35-49C SL280UH110V60C 8268009 14ACX-041-230 TXV 38,500 16.00 13.00 CX35-49C SLP98UH110XV60C 8268004 14ACX-041-230 TXV 38,500 14.50 12.20 CX35-49C 8267997 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 21 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-041-230 TXV 38,000 15.50 12.50 CX35-50/60C EL180UH090E60C 8268010 14ACX-041-230 TXV 38,000 15.50 12.50 CX35-50/60C EL180UH110E60C 8268011 14ACX-041-230 TXV 38,000 15.50 12.50 CX35-50/60C EL180UH110XE60C 8268012 14ACX-041-230 TXV 38,000 15.50 12.50 CX35-50/60C EL195UH090XE48C 8268016 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-50/60C EL195UH110XE60C 8268015 14ACX-041-230 TXV 38,000 15.50 12.50 CX35-50/60C EL296UH090XE48C 8268013 14ACX-041-230 TXV 38,500 15.50 12.50 CX35-50/60C EL296UH110XE60C 8268014 14ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL180UH090E60C 8268017 14ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL180UH110E60C 8268018 14ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL180UH110XE60C 8268019 14ACX-041-230 TXV 39,500 16.00 13.00 CX35-60C EL195UH090XE48C 8268031 14ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL195UH110XE60C 8268030 14ACX-041-230 TXV 39,500 16.00 13.00 CX35-60C EL296UH090XE48C 8268020 14ACX-041-230 TXV 39,500 16.00 13.00 CX35-60C EL296UH090XV36C 8268027 14ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL296UH090XV48C 8268028 14ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL296UH090XV60C 8268029 14ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL296UH110XE60C 8268021 14ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C EL296UH110XV60C 8268026 14ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C SL280UH090V60C 8268032 14ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C SL280UH110V60C 8268033 14ACX-041-230 TXV 39,500 16.00 13.00 CX35-60C SLP98UH090XV36C 8268022 14ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C SLP98UH090XV48C 8268023 14ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C SLP98UH090XV60C 8268024 14ACX-041-230 TXV 40,000 16.00 13.00 CX35-60C SLP98UH110XV60C 8268025 14ACX-047-230 TXV 46,000 15.00 12.50 C33-43 EL180UH090E48B 5735121 14ACX-047-230 TXV 46,000 15.00 12.50 C33-43 EL180UH090XE48B 5737084 14ACX-047-230 TXV 46,000 14.50 12.00 C33-43C 7426640 14ACX-047-230 TXV 45,000 14.70 12.20 C33-48 EL180UH090E48B 5735123 14ACX-047-230 TXV 45,000 15.00 12.50 C33-48 EL180UH090E60C 5736034 14ACX-047-230 TXV 45,000 14.70 12.20 C33-48 EL180UH090XE48B 5737087 14ACX-047-230 TXV 45,500 14.50 12.00 C33-48 EL180UH110E60C 5737886 14ACX-047-230 TXV 45,500 14.50 12.00 C33-48 EL180UH110XE60C 5738947 14ACX-047-230 TXV 45,000 14.70 12.20 C33-48 EL195UH090XE48C 4693919 14ACX-047-230 TXV 45,000 14.70 12.20 C33-48 EL195UH110XE60C 4693931 14ACX-047-230 TXV 45,000 14.70 12.20 C33-48 EL296UH090XE48C 5647264 14ACX-047-230 TXV 45,000 14.70 12.20 C33-48 EL296UH110XE60C 5647227 14ACX-047-230 TXV 45,000 14.70 12.20 C33-48 SL280UH090V60C 3869170 14ACX-047-230 TXV 45,000 14.70 12.20 C33-48 SL280UH090XV60C 4235241 14ACX-047-230 TXV 45,000 14.70 12.20 C33-48 SL280UH110V60C 3869171 14ACX-047-230 TXV 45,000 14.70 12.20 C33-48 SL280UH110XV60C 4040139 14ACX-047-230 TXV 47,000 15.70 13.00 C33-49 EL180UH090E60C 5736035 14ACX-047-230 TXV 46,500 15.70 13.00 C33-49 EL180UH110E60C 5737855 14ACX-047-230 TXV 46,500 15.70 13.00 C33-49 EL180UH110XE60C 5738932 14ACX-047-230 TXV 47,000 15.20 12.70 C33-49 EL195UH090XE48C 4693920 14ACX-047-230 TXV 47,000 15.50 12.70 C33-49 EL195UH110XE60C 4693932 14ACX-047-230 TXV 47,000 15.20 12.70 C33-49 EL296UH090XE48C 5647265 14ACX-047-230 TXV 47,000 15.20 12.70 C33-49 EL296UH090XV48C 5057278 14ACX-047-230 TXV 47,000 15.50 12.70 C33-49 EL296UH090XV60C 5057279 14ACX-047-230 TXV 47,000 15.50 12.70 C33-49 EL296UH110XE60C 5647228 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 22 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-047-230 TXV 47,000 15.50 12.70 C33-49 EL296UH110XV60C 5057280 14ACX-047-230 TXV 47,000 15.70 13.00 C33-49 SL280UH090V60C 4253823 14ACX-047-230 TXV 47,000 15.70 13.00 C33-49 SL280UH110V60C 4253824 14ACX-047-230 TXV 47,000 15.20 12.70 C33-49 SLP98UH090XV48C 5140512 14ACX-047-230 TXV 47,000 15.50 12.70 C33-49 SLP98UH090XV60C 5140513 14ACX-047-230 TXV 47,000 15.50 12.70 C33-49 SLP98UH110XV60C 5140514 14ACX-047-230 TXV 46,500 14.50 12.00 C33-49 7426641 14ACX-047-230 TXV 45,500 15.20 12.50 C33-50/60C EL180UH090E60C 5736038 14ACX-047-230 TXV 46,000 14.70 12.20 C33-50/60C EL180UH110E60C 5737857 14ACX-047-230 TXV 46,000 14.70 12.20 C33-50/60C EL180UH110XE60C 5738935 14ACX-047-230 TXV 45,500 15.00 12.50 C33-50/60C EL195UH090XE48C 4693921 14ACX-047-230 TXV 45,500 15.00 12.50 C33-50/60C EL195UH110XE60C 4693933 14ACX-047-230 TXV 45,500 15.00 12.50 C33-50/60C EL296UH090XE48C 5647266 14ACX-047-230 TXV 45,500 15.00 12.50 C33-50/60C EL296UH110XE60C 5647229 14ACX-047-230 TXV 45,500 14.25 12.00 C33-50/60C 7426642 14ACX-047-230 TXV 47,000 15.70 13.00 C33-60D EL180UH135E60D 5746074 14ACX-047-230 TXV 47,000 15.20 12.70 C33-60D EL195UH135XE60D 4693943 14ACX-047-230 TXV 47,000 15.20 12.70 C33-60D EL296UH135XE60D 5647279 14ACX-047-230 TXV 46,500 14.50 12.00 C33-60D 7426643 14ACX-047-230 TXV 47,500 16.00 13.20 C33-62C EL180UH090E60C 5736040 14ACX-047-230 TXV 47,500 16.00 13.20 C33-62C EL180UH110E60C 5737860 14ACX-047-230 TXV 47,500 16.00 13.20 C33-62C EL180UH110XE60C 5738936 14ACX-047-230 TXV 47,500 15.70 13.00 C33-62C EL195UH090XE48C 4693922 14ACX-047-230 TXV 47,500 15.70 13.00 C33-62C EL195UH110XE60C 4693934 14ACX-047-230 TXV 47,500 15.70 13.00 C33-62C EL296UH090XE48C 5647267 14ACX-047-230 TXV 47,500 15.70 13.00 C33-62C EL296UH110XE60C 5647230 14ACX-047-230 TXV 48,000 16.00 13.00 C33-62C SL280UH090V60C 4253828 14ACX-047-230 TXV 47,500 16.00 13.00 C33-62C SL280UH110V60C 4253829 14ACX-047-230 TXV 47,000 14.50 12.50 C33-62C 3869173 14ACX-047-230 TXV 47,500 15.70 13.20 C33-62D EL180UH135E60D 5746075 14ACX-047-230 TXV 47,000 15.50 12.70 C33-62D EL195UH135XE60D 4693944 14ACX-047-230 TXV 47,000 15.50 12.70 C33-62D EL296UH135XE60D 5647280 14ACX-047-230 TXV 47,000 14.50 12.00 C33-62D 7426644 14ACX-047-230 TXV 46,000 15.00 12.50 C35-48B EL180UH090E48B 8267394 14ACX-047-230 TXV 46,000 15.00 12.50 C35-48B EL180UH090XE48B 8267393 14ACX-047-230 TXV 46,000 15.00 12.50 C35-49C EL180UH090E60C 8267395 14ACX-047-230 TXV 46,500 15.10 12.50 C35-49C EL180UH110E60C 8267396 14ACX-047-230 TXV 46,500 15.10 12.50 C35-49C EL180UH110XE60C 8267397 14ACX-047-230 TXV 46,500 15.10 12.50 C35-49C EL195UH090XE48C 8267407 14ACX-047-230 TXV 46,500 15.50 12.50 C35-49C EL195UH110XE60C 8267406 14ACX-047-230 TXV 46,500 15.10 12.50 C35-49C EL296UH090XE48C 8267399 14ACX-047-230 TXV 47,000 15.10 12.50 C35-49C EL296UH090XV48C 8267403 14ACX-047-230 TXV 47,000 15.10 12.50 C35-49C EL296UH090XV60C 8267404 14ACX-047-230 TXV 46,500 15.50 12.50 C35-49C EL296UH110XE60C 8267398 14ACX-047-230 TXV 47,000 15.10 12.50 C35-49C EL296UH110XV60C 8267405 14ACX-047-230 TXV 47,000 15.50 12.50 C35-49C SL280UH090V60C 8267408 14ACX-047-230 TXV 47,000 15.10 12.50 C35-49C SL280UH110V60C 8267409 14ACX-047-230 TXV 47,000 15.10 12.50 C35-49C SLP98UH090XV48C 8267401 14ACX-047-230 TXV 47,000 15.50 12.50 C35-49C SLP98UH090XV60C 8267402 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 23 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-047-230 TXV 47,000 15.10 12.50 C35-49C SLP98UH110XV60C 8267400 14ACX-047-230 TXV 45,500 15.10 12.50 C35-50/60C EL180UH090E60C 8267410 14ACX-047-230 TXV 46,000 14.50 12.20 C35-50/60C EL180UH110E60C 8267411 14ACX-047-230 TXV 46,000 14.70 12.20 C35-50/60C EL180UH110XE60C 8267412 14ACX-047-230 TXV 45,500 15.00 12.20 C35-50/60C EL195UH090XE48C 8267416 14ACX-047-230 TXV 45,500 15.00 12.50 C35-50/60C EL195UH110XE60C 8267415 14ACX-047-230 TXV 45,500 15.00 12.20 C35-50/60C EL296UH090XE48C 8267414 14ACX-047-230 TXV 45,500 15.00 12.50 C35-50/60C EL296UH110XE60C 8267413 14ACX-047-230 TXV 47,500 16.00 13.00 C35-60C EL180UH090E60C 8267420 14ACX-047-230 TXV 47,500 16.00 13.00 C35-60C EL180UH110E60C 8267421 14ACX-047-230 TXV 47,500 16.00 13.00 C35-60C EL180UH110XE60C 8267422 14ACX-047-230 TXV 47,500 15.50 12.50 C35-60C EL195UH090XE48C 8267426 14ACX-047-230 TXV 47,500 15.50 12.50 C35-60C EL195UH110XE60C 8267425 14ACX-047-230 TXV 47,500 15.50 12.50 C35-60C EL296UH090XE48C 8267424 14ACX-047-230 TXV 47,500 15.50 12.50 C35-60C EL296UH110XE60C 8267423 14ACX-047-230 TXV 48,000 16.00 13.00 C35-60C SL280UH090V60C 8267427 14ACX-047-230 TXV 48,000 16.00 13.00 C35-60C SL280UH090XV60C 8267418 14ACX-047-230 TXV 47,500 16.00 13.00 C35-60C SL280UH110V60C 8267428 14ACX-047-230 TXV 47,500 16.00 13.00 C35-60C SL280UH110XV60C 8267419 14ACX-047-230 TXV 47,000 14.50 12.20 C35-60C 8267417 14ACX-047-230 TXV 47,500 15.50 12.50 C35-60D EL180UH135E60D 8267429 14ACX-047-230 TXV 47,000 15.50 12.50 C35-60D EL195UH135XE60D 8267431 14ACX-047-230 TXV 47,000 15.50 12.50 C35-60D EL296UH135XE60D 8267430 14ACX-047-230 TXV 47,000 16.00 13.00 CBA27UHE-048 10259382 14ACX-047-230 TXV 46,500 15.10 12.50 CBX25UH-048 5732790 14ACX-047-230 TXV 47,000 16.00 13.00 CBX25UHV-048 6970132 14ACX-047-230 TXV 46,500 16.00 13.00 CBX27UH-048 3869174 14ACX-047-230 TXV 46,000 16.00 13.00 CBX32MV-060 3869175 14ACX-047-230 TXV 46,000 16.00 13.00 CBX40UHV-060 3869176 14ACX-047-230 TXV 47,500 15.50 12.70 CH33-43 EL180UH090E48B 5735113 14ACX-047-230 TXV 46,000 15.20 12.70 CH33-43 EL180UH090E60C 5736017 14ACX-047-230 TXV 47,500 15.50 12.70 CH33-43 EL180UH090XE48B 5737077 14ACX-047-230 TXV 46,500 15.00 12.50 CH33-43 EL180UH110E60C 5737841 14ACX-047-230 TXV 46,500 15.00 12.50 CH33-43 EL180UH110XE60C 5738918 14ACX-047-230 TXV 47,000 15.20 12.70 CH33-43 SL280UH090V48B 4016678 14ACX-047-230 TXV 46,500 15.20 12.70 CH33-43 SL280UH090V60C 4253830 14ACX-047-230 TXV 47,000 15.20 12.70 CH33-43 SL280UH090XV48B 4038535 14ACX-047-230 TXV 46,000 15.20 12.50 CH33-43 SL280UH110V60C 4253831 14ACX-047-230 TXV 46,000 15.00 12.50 CH33-43C EL195UH090XE48C 4693923 14ACX-047-230 TXV 46,000 15.20 12.70 CH33-43C EL195UH110XE60C 4693935 14ACX-047-230 TXV 46,000 15.00 12.50 CH33-43C EL296UH090XE48C 5647268 14ACX-047-230 TXV 46,000 15.20 12.70 CH33-43C EL296UH110XE60C 5647231 14ACX-047-230 TXV 46,000 14.25 12.00 CH33-43C 7426645 14ACX-047-230 TXV 45,500 14.70 12.20 CH33-44/48 EL180UH090E48B 5735115 14ACX-047-230 TXV 45,500 14.70 12.20 CH33-44/48 EL180UH090XE48B 5737079 14ACX-047-230 TXV 45,000 14.50 12.00 CH33-44/48 SL280UH090V48B 4016679 14ACX-047-230 TXV 45,000 14.50 12.00 CH33-44/48 SL280UH090XV48B 4038536 14ACX-047-230 TXV 45,500 15.20 12.50 CH33-48 EL180UH090E60C 5736020 14ACX-047-230 TXV 46,500 14.70 12.20 CH33-48 EL180UH110E60C 5737843 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 24 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-047-230 TXV 46,500 14.70 12.20 CH33-48 EL180UH110XE60C 5738921 14ACX-047-230 TXV 46,000 14.70 12.50 CH33-48 EL296UH090XV48C 5057275 14ACX-047-230 TXV 46,000 14.70 12.20 CH33-48 EL296UH090XV60C 5057276 14ACX-047-230 TXV 46,000 14.70 12.50 CH33-48 EL296UH110XV60C 5057277 14ACX-047-230 TXV 46,000 15.20 12.50 CH33-48 SL280UH090V60C 3869180 14ACX-047-230 TXV 46,000 15.20 12.50 CH33-48 SL280UH090XV60C 4235242 14ACX-047-230 TXV 46,000 15.00 12.50 CH33-48 SL280UH110V60C 3869181 14ACX-047-230 TXV 46,000 15.00 12.50 CH33-48 SL280UH110XV60C 4040143 14ACX-047-230 TXV 46,000 14.70 12.50 CH33-48 SLP98UH090XV48C 5140465 14ACX-047-230 TXV 46,000 14.70 12.20 CH33-48 SLP98UH090XV60C 5140466 14ACX-047-230 TXV 46,000 14.70 12.50 CH33-48 SLP98UH110XV60C 5140467 14ACX-047-230 TXV 45,500 14.70 12.50 CH33-48C EL195UH090XE48C 4693924 14ACX-047-230 TXV 45,500 14.70 12.50 CH33-48C EL195UH110XE60C 4693936 14ACX-047-230 TXV 45,500 14.70 12.50 CH33-48C EL296UH090XE48C 5647269 14ACX-047-230 TXV 45,500 14.70 12.50 CH33-48C EL296UH110XE60C 5647232 14ACX-047-230 TXV 45,500 14.25 12.00 CH33-48C 7426646 14ACX-047-230 TXV 46,500 15.50 12.70 CH33-49 EL180UH090E60C 5736022 14ACX-047-230 TXV 47,500 15.20 12.70 CH33-49 EL180UH110E60C 5737845 14ACX-047-230 TXV 47,500 15.20 12.70 CH33-49 EL180UH110XE60C 5738922 14ACX-047-230 TXV 46,500 15.20 12.70 CH33-49 EL195UH090XE48C 4693925 14ACX-047-230 TXV 46,500 15.20 12.70 CH33-49 EL195UH110XE60C 4693937 14ACX-047-230 TXV 46,500 15.20 12.70 CH33-49 EL296UH090XE48C 5647270 14ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 EL296UH090XV48C 5057284 14ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 EL296UH090XV60C 5057285 14ACX-047-230 TXV 46,500 15.20 12.70 CH33-49 EL296UH110XE60C 5647233 14ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 EL296UH110XV60C 5057286 14ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 SLP98UH090XV48C 5140537 14ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 SLP98UH090XV60C 5140538 14ACX-047-230 TXV 47,000 15.20 12.70 CH33-49 SLP98UH110XV60C 5140539 14ACX-047-230 TXV 46,500 14.50 12.00 CH33-49 7426652 14ACX-047-230 TXV 46,500 15.50 12.70 CH33-50/60C EL180UH090E60C 5736024 14ACX-047-230 TXV 47,000 15.00 12.50 CH33-50/60C EL180UH110E60C 5737847 14ACX-047-230 TXV 47,000 15.00 12.50 CH33-50/60C EL180UH110XE60C 5738925 14ACX-047-230 TXV 46,500 15.20 12.70 CH33-50/60C EL195UH090XE48C 4693926 14ACX-047-230 TXV 46,500 15.20 12.70 CH33-50/60C EL195UH110XE60C 4693938 14ACX-047-230 TXV 46,500 15.20 12.70 CH33-50/60C EL296UH090XE48C 5647271 14ACX-047-230 TXV 46,500 15.20 12.70 CH33-50/60C EL296UH110XE60C 5647234 14ACX-047-230 TXV 46,500 14.50 12.20 CH33-50/60C 4253835 14ACX-047-230 TXV 46,500 15.50 12.70 CH33-60D EL180UH135E60D 5746070 14ACX-047-230 TXV 46,500 15.00 12.50 CH33-60D EL195UH135XE60D 4693945 14ACX-047-230 TXV 46,500 15.00 12.50 CH33-60D EL296UH135XE60D 5647281 14ACX-047-230 TXV 46,000 14.25 12.00 CH33-60D 7426647 14ACX-047-230 TXV 47,000 15.70 13.00 CH33-62D EL180UH135E60D 5746071 14ACX-047-230 TXV 47,000 15.20 12.70 CH33-62D EL195UH135XE60D 4693946 14ACX-047-230 TXV 47,000 15.20 12.70 CH33-62D EL296UH135XE60D 5647282 14ACX-047-230 TXV 46,500 14.50 12.00 CH33-62D 7426648 14ACX-047-230 TXV 47,500 15.50 12.50 CH35-42B EL180UH090E48B 7163952 14ACX-047-230 TXV 47,500 15.00 12.50 CH35-42B SL280UH090XV48B 7163955 14ACX-047-230 TXV 47,000 14.50 12.00 CH35-42B 7163957 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 25 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-047-230 TXV 46,000 15.10 12.50 CH35-42C EL180UH090E60C 7163970 14ACX-047-230 TXV 47,000 15.00 12.50 CH35-42C EL180UH110E60C 7163972 14ACX-047-230 TXV 46,000 15.10 12.50 CH35-42C EL195UH090XE48C 7163961 14ACX-047-230 TXV 46,000 15.10 12.50 CH35-42C EL195UH110XE60C 7163963 14ACX-047-230 TXV 46,000 15.10 12.50 CH35-42C EL296UH090XE48C 7163965 14ACX-047-230 TXV 46,000 15.10 12.50 CH35-42C EL296UH110XE60C 7163968 14ACX-047-230 TXV 46,500 15.10 12.50 CH35-42C SL280UH090V60C 7163974 14ACX-047-230 TXV 46,500 15.10 12.50 CH35-42C SL280UH110V60C 7163976 14ACX-047-230 TXV 46,500 15.00 12.50 CH35-42C SLP98UH090XV48C 7163978 14ACX-047-230 TXV 46,500 15.00 12.50 CH35-42C SLP98UH090XV60C 7163981 14ACX-047-230 TXV 46,500 15.00 12.50 CH35-42C SLP98UH110XV60C 7163982 14ACX-047-230 TXV 46,000 14.50 12.00 CH35-42C 7163959 14ACX-047-230 TXV 46,000 15.00 12.50 CH35-48B EL180UH090E48B 7163985 14ACX-047-230 TXV 46,000 14.50 12.00 CH35-48B SL280UH090V48B 7163988 14ACX-047-230 TXV 46,000 14.50 12.00 CH35-48B 7163991 14ACX-047-230 TXV 46,000 15.10 12.50 CH35-48C EL180UH090E60C 7164014 14ACX-047-230 TXV 46,500 15.00 12.50 CH35-48C EL180UH110E60C 7164016 14ACX-047-230 TXV 46,000 15.00 12.50 CH35-48C EL195UH090XE48C 7163995 14ACX-047-230 TXV 46,000 15.10 12.50 CH35-48C EL195UH110XE60C 7163998 14ACX-047-230 TXV 46,000 15.00 12.50 CH35-48C EL296UH090XE48C 7164001 14ACX-047-230 TXV 46,000 15.00 12.50 CH35-48C EL296UH090XV48C 7164003 14ACX-047-230 TXV 46,000 15.00 12.00 CH35-48C EL296UH090XV60C 7164006 14ACX-047-230 TXV 46,000 15.10 12.50 CH35-48C EL296UH110XE60C 7164009 14ACX-047-230 TXV 46,000 15.00 12.50 CH35-48C EL296UH110XV60C 7164011 14ACX-047-230 TXV 46,500 15.10 12.50 CH35-48C SL280UH090V60C 7164019 14ACX-047-230 TXV 46,000 15.10 12.50 CH35-48C SL280UH110V60C 7164021 14ACX-047-230 TXV 46,000 15.00 12.50 CH35-48C SLP98UH090XV48C 7164025 14ACX-047-230 TXV 46,000 15.00 12.00 CH35-48C SLP98UH090XV60C 7164027 14ACX-047-230 TXV 46,000 15.00 12.50 CH35-48C SLP98UH110XV60C 7164030 14ACX-047-230 TXV 46,000 14.50 12.00 CH35-48C 7163993 14ACX-047-230 TXV 47,000 15.50 13.00 CH35-51C EL180UH090E60C 7164054 14ACX-047-230 TXV 47,500 15.10 12.50 CH35-51C EL180UH110E60C 7164056 14ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C EL195UH090XE48C 7164035 14ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C EL195UH110XE60C 7164038 14ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C EL296UH090XE48C 7164042 14ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C EL296UH090XV48C 7164044 14ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C EL296UH090XV60C 7164047 14ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C EL296UH110XE60C 7164049 14ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C EL296UH110XV60C 7164052 14ACX-047-230 TXV 47,000 15.50 12.50 CH35-51C SL280UH090V60C 7164059 14ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C SL280UH110V60C 7164062 14ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C SLP98UH090XV48C 7164065 14ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C SLP98UH090XV60C 7164067 14ACX-047-230 TXV 47,000 15.10 12.50 CH35-51C SLP98UH110XV60C 7164070 14ACX-047-230 TXV 47,000 14.50 12.00 CH35-51C 7164033 14ACX-047-230 TXV 47,500 15.50 13.00 CH35-60D EL180UH135E60D 7164080 14ACX-047-230 TXV 47,000 15.10 12.50 CH35-60D EL195UH135XE60D 7164075 14ACX-047-230 TXV 47,000 15.10 12.50 CH35-60D EL296UH135XE60D 7164078 14ACX-047-230 TXV 47,000 15.50 13.00 CH35-60D SL280UH135V60D 7164083 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 26 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-047-230 TXV 47,000 15.50 12.50 CH35-60D SLP98UH135XV60D 10040425 14ACX-047-230 TXV 47,000 14.50 12.00 CH35-60D 7164073 14ACX-047-230 TXV 45,000 15.20 12.50 CR33-50/60 EL180DF110E60C 5733507 14ACX-047-230 TXV 44,500 14.70 12.20 CR33-50/60 EL195DF090XE48C 4693917 14ACX-047-230 TXV 44,500 15.20 12.20 CR33-50/60 EL195DF110XE60C 4693918 14ACX-047-230 TXV 44,500 14.70 12.20 CR33-50/60 EL296DF090XE48C 5647262 14ACX-047-230 TXV 44,500 15.20 12.20 CR33-50/60 EL296DF110XE60C 5647263 14ACX-047-230 TXV 45,500 15.70 13.00 CR33-50/60 SL280DF090V60C 3869186 14ACX-047-230 TXV 45,500 15.70 13.00 CR33-50/60 SL280DF110V60C 3869187 14ACX-047-230 TXV 46,000 15.00 12.50 CX34-43 EL180UH090E48B 5735116 14ACX-047-230 TXV 46,000 15.00 12.50 CX34-43 EL180UH090XE48B 5737081 14ACX-047-230 TXV 46,000 14.70 12.50 CX34-43 SL280UH090V48B 4016676 14ACX-047-230 TXV 46,000 14.70 12.50 CX34-43 SL280UH090XV48B 4038533 14ACX-047-230 TXV 46,000 14.25 12.00 CX34-43C 7426649 14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL180UH090E48B 5735118 14ACX-047-230 TXV 45,000 15.00 12.50 CX34-44/48 EL180UH090E60C 5736026 14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL180UH090XE48B 5737083 14ACX-047-230 TXV 45,500 14.50 12.00 CX34-44/48 EL180UH110E60C 5737884 14ACX-047-230 TXV 45,500 14.50 12.00 CX34-44/48 EL180UH110XE60C 5738944 14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL195UH090XE48C 4693927 14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL195UH110XE60C 4693939 14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL296UH090XE48C 5647272 14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL296UH090XV48C 5057272 14ACX-047-230 TXV 45,000 14.50 12.20 CX34-44/48 EL296UH090XV60C 5057273 14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL296UH110XE60C 5647235 14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 EL296UH110XV60C 5057274 14ACX-047-230 TXV 45,000 14.50 12.20 CX34-44/48 SL280UH090V48B 4016677 14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SL280UH090V60C 3869194 14ACX-047-230 TXV 45,000 14.50 12.20 CX34-44/48 SL280UH090XV48B 4038534 14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SL280UH090XV60C 4235243 14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SL280UH110V60C 3869195 14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SL280UH110XV60C 4040147 14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SLP98UH090XV48C 5140462 14ACX-047-230 TXV 45,000 14.50 12.20 CX34-44/48 SLP98UH090XV60C 5140463 14ACX-047-230 TXV 45,000 14.70 12.20 CX34-44/48 SLP98UH110XV60C 5140464 14ACX-047-230 TXV 47,000 15.70 13.00 CX34-49 EL180UH090E60C 5736028 14ACX-047-230 TXV 46,500 15.70 13.00 CX34-49 EL180UH110E60C 5737850 14ACX-047-230 TXV 46,500 15.70 13.00 CX34-49 EL180UH110XE60C 5738926 14ACX-047-230 TXV 47,000 15.20 12.70 CX34-49 EL195UH090XE48C 4693928 14ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 EL195UH110XE60C 4693940 14ACX-047-230 TXV 47,000 15.20 12.70 CX34-49 EL296UH090XE48C 5647273 14ACX-047-230 TXV 47,000 15.20 12.70 CX34-49 EL296UH090XV48C 5057281 14ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 EL296UH090XV60C 5057282 14ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 EL296UH110XE60C 5647276 14ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 EL296UH110XV60C 5057283 14ACX-047-230 TXV 47,000 15.70 13.00 CX34-49 SL280UH090V60C 4253836 14ACX-047-230 TXV 47,000 15.70 13.00 CX34-49 SL280UH110V60C 4253837 14ACX-047-230 TXV 47,000 15.20 12.70 CX34-49 SLP98UH090XV48C 5140524 14ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 SLP98UH090XV60C 5140525 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 27 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-047-230 TXV 47,000 15.50 12.70 CX34-49 SLP98UH110XV60C 5140526 14ACX-047-230 TXV 46,500 14.50 12.00 CX34-49 7426653 14ACX-047-230 TXV 45,500 15.20 12.50 CX34-50/60C EL180UH090E60C 5736030 14ACX-047-230 TXV 46,000 14.70 12.20 CX34-50/60C EL180UH110E60C 5737851 14ACX-047-230 TXV 46,000 14.70 12.20 CX34-50/60C EL180UH110XE60C 5738929 14ACX-047-230 TXV 45,500 15.00 12.50 CX34-50/60C EL195UH090XE48C 4693929 14ACX-047-230 TXV 45,500 15.00 12.50 CX34-50/60C EL195UH110XE60C 4693941 14ACX-047-230 TXV 45,500 15.00 12.50 CX34-50/60C EL296UH090XE48C 5647274 14ACX-047-230 TXV 45,500 15.00 12.50 CX34-50/60C EL296UH110XE60C 5647277 14ACX-047-230 TXV 45,500 14.25 12.00 CX34-50/60C 7426657 14ACX-047-230 TXV 47,000 15.70 13.00 CX34-60D EL180UH135E60D 5746072 14ACX-047-230 TXV 47,000 15.20 12.70 CX34-60D EL195UH135XE60D 4693947 14ACX-047-230 TXV 47,000 15.20 12.70 CX34-60D EL296UH135XE60D 5647283 14ACX-047-230 TXV 46,500 14.50 12.00 CX34-60D 7426654 14ACX-047-230 TXV 47,500 16.00 13.20 CX34-62C EL180UH090E60C 5736032 14ACX-047-230 TXV 47,500 16.00 13.20 CX34-62C EL180UH110E60C 5737854 14ACX-047-230 TXV 47,500 16.00 13.20 CX34-62C EL180UH110XE60C 5738931 14ACX-047-230 TXV 47,500 15.70 13.00 CX34-62C EL195UH090XE48C 4693930 14ACX-047-230 TXV 47,500 15.70 13.00 CX34-62C EL195UH110XE60C 4693942 14ACX-047-230 TXV 47,500 15.70 13.00 CX34-62C EL296UH090XE48C 5647275 14ACX-047-230 TXV 47,500 15.70 13.00 CX34-62C EL296UH110XE60C 5647278 14ACX-047-230 TXV 48,000 16.00 13.00 CX34-62C SL280UH090V60C 4253841 14ACX-047-230 TXV 47,500 16.00 13.00 CX34-62C SL280UH110V60C 4253842 14ACX-047-230 TXV 47,000 14.70 12.50 CX34-62C 3869197 14ACX-047-230 TXV 47,500 15.70 13.20 CX34-62D EL180UH135E60D 5746073 14ACX-047-230 TXV 47,000 15.50 12.70 CX34-62D EL195UH135XE60D 4693948 14ACX-047-230 TXV 47,000 15.50 12.70 CX34-62D EL296UH135XE60D 5647284 14ACX-047-230 TXV 47,000 14.50 12.00 CX34-62D 7426655 14ACX-047-230 TXV 46,000 15.00 12.50 CX35-48B EL180UH090E48B 8267433 14ACX-047-230 TXV 46,000 15.00 12.50 CX35-48B EL180UH090XE48B 8267432 14ACX-047-230 TXV 46,000 14.50 12.20 CX35-48B SL280UH090V48B 8267435 14ACX-047-230 TXV 46,000 14.50 12.20 CX35-48B SL280UH090XV48B 8267434 14ACX-047-230 TXV 46,500 15.10 12.50 CX35-49C EL180UH110E60C 8267436 14ACX-047-230 TXV 46,500 15.10 12.50 CX35-49C EL180UH110XE60C 8267437 14ACX-047-230 TXV 46,500 15.10 12.50 CX35-49C EL195UH090XE48C 8267447 14ACX-047-230 TXV 46,500 15.50 12.50 CX35-49C EL195UH110XE60C 8267446 14ACX-047-230 TXV 46,500 15.10 12.50 CX35-49C EL296UH090XE48C 8267438 14ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C EL296UH090XV48C 8267443 14ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C EL296UH090XV60C 8267444 14ACX-047-230 TXV 46,500 15.50 12.50 CX35-49C EL296UH110XE60C 8267439 14ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C EL296UH110XV60C 8267445 14ACX-047-230 TXV 47,000 15.50 12.50 CX35-49C SL280UH090V60C 8267448 14ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C SL280UH110V60C 8267449 14ACX-047-230 TXV 47,000 15.00 12.50 CX35-49C SLP98UH090XV48C 8267441 14ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C SLP98UH090XV60C 8267442 14ACX-047-230 TXV 47,000 15.10 12.50 CX35-49C SLP98UH110XV60C 8267440 14ACX-047-230 TXV 45,500 15.10 12.50 CX35-50/60C EL180UH090E60C 8267450 14ACX-047-230 TXV 46,000 14.50 12.20 CX35-50/60C EL180UH110E60C 8267451 14ACX-047-230 TXV 46,000 14.70 12.20 CX35-50/60C EL180UH110XE60C 8267452 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 28 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-047-230 TXV 45,500 15.00 12.20 CX35-50/60C EL195UH090XE48C 8267456 14ACX-047-230 TXV 45,500 15.00 12.50 CX35-50/60C EL195UH110XE60C 8267455 14ACX-047-230 TXV 45,500 15.00 12.50 CX35-50/60C EL296UH090XE48C 8267453 14ACX-047-230 TXV 45,500 15.00 12.20 CX35-50/60C EL296UH110XE60C 8267454 14ACX-047-230 TXV 47,500 16.00 13.00 CX35-60C EL180UH090E60C 8267460 14ACX-047-230 TXV 47,500 16.00 13.00 CX35-60C EL180UH110E60C 8267461 14ACX-047-230 TXV 47,500 16.00 13.00 CX35-60C EL180UH110XE60C 8267462 14ACX-047-230 TXV 47,500 15.50 12.50 CX35-60C EL195UH090XE48C 8267466 14ACX-047-230 TXV 47,500 15.50 12.50 CX35-60C EL195UH110XE60C 8267465 14ACX-047-230 TXV 47,500 15.50 12.50 CX35-60C EL296UH090XE48C 8267463 14ACX-047-230 TXV 47,500 15.50 12.50 CX35-60C EL296UH110XE60C 8267464 14ACX-047-230 TXV 48,000 16.00 13.00 CX35-60C SL280UH090V60C 8267467 14ACX-047-230 TXV 48,000 16.00 13.00 CX35-60C SL280UH090XV60C 8267458 14ACX-047-230 TXV 47,500 16.00 13.00 CX35-60C SL280UH110V60C 8267468 14ACX-047-230 TXV 47,500 16.00 13.00 CX35-60C SL280UH110XV60C 8267459 14ACX-047-230 TXV 47,000 14.50 12.20 CX35-60C 8267457 14ACX-047-230 TXV 47,500 15.50 12.50 CX35-60D EL180UH135E60D 8267469 14ACX-047-230 TXV 47,000 15.50 12.50 CX35-60D EL195UH135XE60D 8267471 14ACX-047-230 TXV 47,000 15.50 12.50 CX35-60D EL296UH135XE60D 8267470 14ACX-048-230 TXV 48,000 14.25 12.00 C33-43B EL180UH090E48B 9138625 14ACX-048-230 TXV 48,000 14.25 12.00 C33-43B EL180UH090XE48B 9138626 14ACX-048-230 TXV 48,000 14.50 12.00 C33-43C EL180UH090E60C 9139151 14ACX-048-230 TXV 47,500 14.50 12.00 C33-43C EL180UH110E60C 9139152 14ACX-048-230 TXV 47,500 14.50 12.00 C33-43C EL180UH110XE60C 9139153 14ACX-048-230 TXV 48,000 14.50 12.00 C33-43C EL195UH090XE48C 9138627 14ACX-048-230 TXV 48,000 14.50 12.00 C33-43C EL195UH110XE60C 9139157 14ACX-048-230 TXV 48,000 14.50 12.00 C33-43C EL296UH090XE48C 9138628 14ACX-048-230 TXV 48,000 14.25 12.00 C33-43C EL296UH090XV48C 9139159 14ACX-048-230 TXV 48,000 14.25 12.00 C33-43C EL296UH090XV60C 9139160 14ACX-048-230 TXV 48,000 14.50 12.00 C33-43C EL296UH110XE60C 9139158 14ACX-048-230 TXV 48,000 14.50 12.00 C33-43C EL296UH110XV48C 9139161 14ACX-048-230 TXV 48,000 14.25 12.00 C33-43C EL296UH110XV60C 9139162 14ACX-048-230 TXV 48,000 14.50 12.00 C33-43C SL280UH090V60C 9139155 14ACX-048-230 TXV 48,000 14.50 12.00 C33-43C SL280UH090XV60C 9139154 14ACX-048-230 TXV 48,000 14.50 12.00 C33-43C SL280UH110V60C 9139156 14ACX-048-230 TXV 48,000 14.50 12.00 C33-43C SL280UH110XV60C 9139145 14ACX-048-230 TXV 48,000 14.25 12.00 C33-43C SLP98UH090XV48C 9139146 14ACX-048-230 TXV 48,000 14.25 12.00 C33-43C SLP98UH090XV60C 9139147 14ACX-048-230 TXV 48,000 14.25 12.00 C33-43C SLP98UH110XV60C 9139148 14ACX-048-230 TXV 47,000 14.00 11.70 C33-48B EL180UH090E48B 9139149 14ACX-048-230 TXV 47,000 14.00 11.70 C33-48B EL180UH090XE48B 9139150 14ACX-048-230 TXV 46,500 14.25 11.70 C33-48C EL180UH090E60C 9139133 14ACX-048-230 TXV 47,500 14.00 11.70 C33-48C EL180UH110E60C 9139134 14ACX-048-230 TXV 47,500 14.00 11.70 C33-48C EL180UH110XE60C 9139135 14ACX-048-230 TXV 46,500 14.00 11.70 C33-48C EL195UH090XE48C 9139139 14ACX-048-230 TXV 46,500 14.00 11.70 C33-48C EL195UH110XE60C 9139141 14ACX-048-230 TXV 46,500 14.00 11.70 C33-48C EL296UH090XE48C 9139140 14ACX-048-230 TXV 47,000 14.00 11.70 C33-48C EL296UH090XV48C 9139143 14ACX-048-230 TXV 46,500 14.00 11.70 C33-48C EL296UH110XE60C 9139142 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 29 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-048-230 TXV 47,000 14.00 11.70 C33-48C EL296UH110XV48C 9139144 14ACX-048-230 TXV 47,000 14.25 11.70 C33-48C SL280UH090V60C 9139136 14ACX-048-230 TXV 47,000 14.25 11.70 C33-48C SL280UH090XV60C 9139137 14ACX-048-230 TXV 47,000 14.00 11.70 C33-48C SL280UH110V60C 9139138 14ACX-048-230 TXV 47,000 14.00 11.70 C33-48C SL280UH110XV60C 9139127 14ACX-048-230 TXV 47,000 14.00 11.70 C33-48C SLP98UH090XV48C 9139128 14ACX-048-230 TXV 48,000 15.00 12.50 C33-49 EL180UH090E60C 9139125 14ACX-048-230 TXV 48,000 15.00 12.00 C33-49 EL180UH110E60C 9139126 14ACX-048-230 TXV 48,000 15.00 12.00 C33-49 EL180UH110XE60C 9139115 14ACX-048-230 TXV 48,000 14.50 12.00 C33-49 EL195UH090XE48C 9139129 14ACX-048-230 TXV 48,000 14.50 12.00 C33-49 EL195UH110XE60C 9139131 14ACX-048-230 TXV 48,000 14.50 12.00 C33-49 EL296UH090XE48C 9139130 14ACX-048-230 TXV 48,000 14.50 12.00 C33-49 EL296UH090XV48C 9139121 14ACX-048-230 TXV 48,000 14.50 12.00 C33-49 EL296UH090XV60C 9139122 14ACX-048-230 TXV 48,000 14.50 12.00 C33-49 EL296UH110XE60C 9139132 14ACX-048-230 TXV 48,000 14.50 12.00 C33-49 EL296UH110XV48C 9139123 14ACX-048-230 TXV 48,000 14.50 12.00 C33-49 EL296UH110XV60C 9139124 14ACX-048-230 TXV 48,000 15.00 12.50 C33-49 SL280UH090V60C 9139116 14ACX-048-230 TXV 48,000 15.00 12.50 C33-49 SL280UH090XV60C 9139117 14ACX-048-230 TXV 48,000 15.00 12.50 C33-49 SL280UH110V60C 9139118 14ACX-048-230 TXV 48,000 15.00 12.50 C33-49 SL280UH110XV60C 9139119 14ACX-048-230 TXV 48,000 14.50 12.00 C33-49 SLP98UH090XV48C 9139120 14ACX-048-230 TXV 48,000 14.50 12.00 C33-49 SLP98UH090XV60C 9139109 14ACX-048-230 TXV 48,000 14.50 12.00 C33-49 SLP98UH110XV60C 9139110 14ACX-048-230 TXV 48,000 14.00 11.70 C33-49 9138603 14ACX-048-230 TXV 47,500 14.50 12.00 C33-50/60C EL180UH090E60C 9139107 14ACX-048-230 TXV 48,000 14.00 11.70 C33-50/60C EL180UH110E60C 9139108 14ACX-048-230 TXV 48,000 14.00 11.70 C33-50/60C EL180UH110XE60C 9139097 14ACX-048-230 TXV 47,500 14.25 12.00 C33-50/60C EL195UH090XE48C 9139111 14ACX-048-230 TXV 47,500 14.25 12.00 C33-50/60C EL195UH110XE60C 9139113 14ACX-048-230 TXV 47,500 14.25 12.00 C33-50/60C EL296UH090XE48C 9139112 14ACX-048-230 TXV 47,500 14.00 11.70 C33-50/60C EL296UH090XV48C 9139103 14ACX-048-230 TXV 47,500 14.00 11.70 C33-50/60C EL296UH090XV60C 9139104 14ACX-048-230 TXV 47,500 14.25 12.00 C33-50/60C EL296UH110XE60C 9139114 14ACX-048-230 TXV 47,500 14.25 11.70 C33-50/60C EL296UH110XV48C 9139105 14ACX-048-230 TXV 47,500 14.00 11.70 C33-50/60C EL296UH110XV60C 9139106 14ACX-048-230 TXV 47,500 14.25 12.00 C33-50/60C SL280UH090V60C 9139098 14ACX-048-230 TXV 47,500 14.25 12.00 C33-50/60C SL280UH090XV60C 9139099 14ACX-048-230 TXV 47,500 14.25 12.00 C33-50/60C SL280UH110V60C 9139100 14ACX-048-230 TXV 47,500 14.25 12.00 C33-50/60C SL280UH110XV60C 9139101 14ACX-048-230 TXV 47,500 14.00 11.70 C33-50/60C SLP98UH090XV48C 9139102 14ACX-048-230 TXV 47,500 14.00 11.70 C33-50/60C SLP98UH090XV60C 9139091 14ACX-048-230 TXV 47,500 14.00 11.70 C33-50/60C SLP98UH110XV60C 9139092 14ACX-048-230 TXV 48,000 14.50 12.50 C33-60D EL180UH135E60D 9139096 14ACX-048-230 TXV 48,000 14.50 12.00 C33-60D EL195UH135XE60D 9139093 14ACX-048-230 TXV 48,000 14.50 12.00 C33-60D EL296UH135XE60D 9139094 14ACX-048-230 TXV 48,000 14.50 12.00 C33-60D EL296UH135XV60D 9139095 14ACX-048-230 TXV 48,000 15.00 12.50 C33-60D SL280UH135V60D 9139085 14ACX-048-230 TXV 48,000 14.50 12.00 C33-60D SLP98UH135XV60D 9139086 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 30 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-048-230 TXV 48,000 14.00 11.70 C33-60D 9138604 14ACX-048-230 TXV 48,000 15.10 12.50 C33-62C EL180UH090E60C 9139425 14ACX-048-230 TXV 48,000 15.00 12.50 C33-62C EL180UH110E60C 9139084 14ACX-048-230 TXV 48,000 15.00 12.50 C33-62C EL180UH110XE60C 9139076 14ACX-048-230 TXV 48,000 14.50 12.50 C33-62C EL195UH090XE48C 9139087 14ACX-048-230 TXV 48,000 15.00 12.50 C33-62C EL195UH110XE60C 9139089 14ACX-048-230 TXV 48,000 14.50 12.50 C33-62C EL296UH090XE48C 9139088 14ACX-048-230 TXV 48,000 14.50 12.00 C33-62C EL296UH090XV48C 9139080 14ACX-048-230 TXV 48,000 14.50 12.00 C33-62C EL296UH090XV60C 9139081 14ACX-048-230 TXV 48,000 15.00 12.50 C33-62C EL296UH110XE60C 9139090 14ACX-048-230 TXV 48,000 15.00 12.50 C33-62C EL296UH110XV48C 9139082 14ACX-048-230 TXV 48,000 14.50 12.50 C33-62C EL296UH110XV60C 9139083 14ACX-048-230 TXV 48,000 15.10 12.50 C33-62C SL280UH090V60C 9139423 14ACX-048-230 TXV 48,000 15.10 12.50 C33-62C SL280UH090XV60C 9139424 14ACX-048-230 TXV 48,000 15.00 12.50 C33-62C SL280UH110V60C 9139077 14ACX-048-230 TXV 48,000 15.00 12.50 C33-62C SL280UH110XV60C 9139078 14ACX-048-230 TXV 48,000 14.50 12.00 C33-62C SLP98UH090XV48C 9139079 14ACX-048-230 TXV 48,000 14.50 12.00 C33-62C SLP98UH090XV60C 9139070 14ACX-048-230 TXV 48,000 14.50 12.50 C33-62C SLP98UH110XV60C 9139071 14ACX-048-230 TXV 48,000 14.25 12.00 C33-62C 9138605 14ACX-048-230 TXV 48,000 15.00 12.50 C33-62D EL180UH135E60D 9139075 14ACX-048-230 TXV 48,000 14.25 12.00 C33-62D EL195UH135XE60D 9139072 14ACX-048-230 TXV 48,000 14.25 12.00 C33-62D EL296UH135XE60D 9139073 14ACX-048-230 TXV 48,000 14.50 12.00 C33-62D EL296UH135XV60D 9139074 14ACX-048-230 TXV 48,000 15.00 12.50 C33-62D SL280UH135V60D 9139064 14ACX-048-230 TXV 48,000 14.50 12.00 C33-62D SLP98UH135XV60D 9139065 14ACX-048-230 TXV 48,000 14.00 11.70 C33-62D 9138606 14ACX-048-230 TXV 48,000 14.25 12.00 C35-48B EL180UH090E48B 9138782 14ACX-048-230 TXV 48,000 14.25 12.00 C35-48B EL180UH090XE48B 9138781 14ACX-048-230 TXV 48,000 14.50 12.00 C35-48C EL180UH090E60C 9138769 14ACX-048-230 TXV 47,500 14.50 12.00 C35-48C EL180UH110E60C 9138770 14ACX-048-230 TXV 47,500 14.50 12.00 C35-48C EL180UH110XE60C 9138771 14ACX-048-230 TXV 48,000 14.50 12.00 C35-48C EL195UH090XE48C 9138772 14ACX-048-230 TXV 48,000 14.50 12.00 C35-48C EL195UH110XE60C 9138762 14ACX-048-230 TXV 48,000 14.50 12.00 C35-48C EL296UH090XE48C 9138761 14ACX-048-230 TXV 48,000 14.00 12.00 C35-48C EL296UH090XV48C 9138764 14ACX-048-230 TXV 48,000 14.00 12.00 C35-48C EL296UH090XV60C 9138778 14ACX-048-230 TXV 48,000 14.50 12.00 C35-48C EL296UH110XE60C 9138763 14ACX-048-230 TXV 48,000 14.50 12.00 C35-48C EL296UH110XV48C 9138767 14ACX-048-230 TXV 48,000 14.00 12.00 C35-48C EL296UH110XV60C 9138768 14ACX-048-230 TXV 48,000 14.50 12.00 C35-48C SL280UH090V60C 9138773 14ACX-048-230 TXV 48,000 14.50 12.00 C35-48C SL280UH090XV60C 9138784 14ACX-048-230 TXV 48,000 14.50 12.00 C35-48C SL280UH110V60C 9138774 14ACX-048-230 TXV 48,000 14.50 12.00 C35-48C SL280UH110XV60C 9138775 14ACX-048-230 TXV 48,000 14.00 12.00 C35-48C SLP98UH090XV48C 9138776 14ACX-048-230 TXV 48,000 14.00 12.00 C35-48C SLP98UH090XV60C 9138777 14ACX-048-230 TXV 48,000 14.25 12.00 C35-48C SLP98UH110XV60C 9138783 14ACX-048-230 TXV 48,000 15.00 12.50 C35-49C EL180UH090E60C 9138759 14ACX-048-230 TXV 48,000 14.00 12.00 C35-49C EL180UH110E60C 9138760 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 31 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-048-230 TXV 48,000 14.00 12.00 C35-49C EL180UH110XE60C 9138749 14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL195UH090XE48C 9138746 14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL195UH110XE60C 9138753 14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL296UH090XE48C 9138752 14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL296UH090XV48C 9138743 14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL296UH090XV60C 9138744 14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL296UH110XE60C 9138754 14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL296UH110XV48C 9138745 14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C EL296UH110XV60C 9138758 14ACX-048-230 TXV 48,000 15.00 12.50 C35-49C SL280UH090V60C 9138750 14ACX-048-230 TXV 48,000 15.00 12.50 C35-49C SL280UH090XV60C 9138751 14ACX-048-230 TXV 48,000 15.00 12.50 C35-49C SL280UH110V60C 9138765 14ACX-048-230 TXV 48,000 15.00 12.50 C35-49C SL280UH110XV60C 9138766 14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C SLP98UH090XV48C 9138755 14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C SLP98UH090XV60C 9138756 14ACX-048-230 TXV 48,000 14.50 12.00 C35-49C SLP98UH110XV60C 9138757 14ACX-048-230 TXV 48,000 14.00 11.70 C35-49C 9138613 14ACX-048-230 TXV 47,500 14.50 12.00 C35-50/60C EL180UH090E60C 9138741 14ACX-048-230 TXV 48,000 14.00 11.70 C35-50/60C EL180UH110E60C 9138742 14ACX-048-230 TXV 48,000 14.00 11.70 C35-50/60C EL180UH110XE60C 9138731 14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C EL195UH090XE48C 9138728 14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C EL195UH110XE60C 9138735 14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C EL296UH090XE48C 9138734 14ACX-048-230 TXV 47,500 14.00 11.70 C35-50/60C EL296UH090XV48C 9138725 14ACX-048-230 TXV 47,500 14.00 11.70 C35-50/60C EL296UH090XV60C 9138726 14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C EL296UH110XE60C 9138736 14ACX-048-230 TXV 47,500 14.25 11.70 C35-50/60C EL296UH110XV48C 9138727 14ACX-048-230 TXV 47,500 14.00 11.70 C35-50/60C EL296UH110XV60C 9138740 14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C SL280UH090V60C 9138732 14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C SL280UH090XV60C 9138733 14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C SL280UH110V60C 9138747 14ACX-048-230 TXV 47,500 14.25 12.00 C35-50/60C SL280UH110XV60C 9138748 14ACX-048-230 TXV 47,500 14.00 11.70 C35-50/60C SLP98UH090XV48C 9138737 14ACX-048-230 TXV 47,500 14.00 11.70 C35-50/60C SLP98UH090XV60C 9138738 14ACX-048-230 TXV 47,500 14.00 11.70 C35-50/60C SLP98UH110XV60C 9138739 14ACX-048-230 TXV 48,000 15.10 12.50 C35-60C EL180UH090E60C 9139419 14ACX-048-230 TXV 48,000 15.00 12.50 C35-60C EL180UH110E60C 9138724 14ACX-048-230 TXV 48,000 15.00 12.50 C35-60C EL180UH110XE60C 9138716 14ACX-048-230 TXV 48,000 14.50 12.50 C35-60C EL195UH090XE48C 9138713 14ACX-048-230 TXV 48,000 15.00 12.50 C35-60C EL195UH110XE60C 9138718 14ACX-048-230 TXV 48,000 14.50 12.50 C35-60C EL296UH090XE48C 9138717 14ACX-048-230 TXV 48,000 14.50 12.00 C35-60C EL296UH090XV48C 9138710 14ACX-048-230 TXV 48,000 14.50 12.00 C35-60C EL296UH090XV60C 9138711 14ACX-048-230 TXV 48,000 15.00 12.50 C35-60C EL296UH110XE60C 9138719 14ACX-048-230 TXV 48,000 15.00 12.50 C35-60C EL296UH110XV48C 9138712 14ACX-048-230 TXV 48,000 14.50 12.50 C35-60C EL296UH110XV60C 9138723 14ACX-048-230 TXV 48,000 15.10 12.50 C35-60C SL280UH090V60C 9139417 14ACX-048-230 TXV 48,000 15.10 12.50 C35-60C SL280UH090XV60C 9139418 14ACX-048-230 TXV 48,000 15.00 12.50 C35-60C SL280UH110V60C 9138729 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 32 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-048-230 TXV 48,000 15.00 12.50 C35-60C SL280UH110XV60C 9138730 14ACX-048-230 TXV 48,000 14.50 12.00 C35-60C SLP98UH090XV48C 9138720 14ACX-048-230 TXV 48,000 14.50 12.00 C35-60C SLP98UH090XV60C 9138721 14ACX-048-230 TXV 48,000 14.50 12.50 C35-60C SLP98UH110XV60C 9138722 14ACX-048-230 TXV 48,000 14.00 11.70 C35-60C 9138614 14ACX-048-230 TXV 48,000 15.00 12.50 C35-60D EL180UH135E60D 9138704 14ACX-048-230 TXV 48,000 14.25 12.00 C35-60D EL195UH135XE60D 9138707 14ACX-048-230 TXV 48,000 14.25 12.00 C35-60D EL296UH135XE60D 9138714 14ACX-048-230 TXV 48,000 14.50 12.00 C35-60D EL296UH135XV60D 9138715 14ACX-048-230 TXV 48,000 15.00 12.50 C35-60D SL280UH135V60D 9138705 14ACX-048-230 TXV 48,000 14.50 12.00 C35-60D SLP98UH135XV60D 9138706 14ACX-048-230 TXV 48,000 14.00 11.70 C35-60D 9138615 14ACX-048-230 TXV 48,000 14.50 12.20 CBA27UHE-048 10259383 14ACX-048-230 TXV 48,000 15.00 12.50 CBA27UHE-060 10259384 14ACX-048-230 TXV 48,000 14.50 12.00 CBX25UH-048 9139066 14ACX-048-230 TXV 48,000 14.50 12.50 CBX25UHV-048 9139067 14ACX-048-230 TXV 48,000 14.50 12.00 CBX27UH-048 9139068 14ACX-048-230 TXV 48,000 15.00 12.50 CBX27UH-060 9139069 14ACX-048-230 TXV 48,000 14.25 12.00 CBX32M-048 9139058 14ACX-048-230 TXV 48,000 14.25 12.00 CBX32M-060 9139059 14ACX-048-230 TXV 48,000 14.25 12.00 CBX32MV-048 9139060 14ACX-048-230 TXV 48,000 14.50 12.00 CBX32MV-060 9139061 14ACX-048-230 TXV 47,500 14.50 12.00 CBX40UHV-048 9139062 14ACX-048-230 TXV 48,000 14.50 12.00 CBX40UHV-060 9139063 14ACX-048-230 TXV 46,000 14.00 11.70 CH23-51 EL180UH090E48B 9139052 14ACX-048-230 TXV 45,500 14.00 11.70 CH23-51 EL180UH110E60C 9139053 14ACX-048-230 TXV 45,500 14.00 11.70 CH23-51 EL180UH110XE60C 9139054 14ACX-048-230 TXV 47,000 14.25 11.70 CH23-65 EL180UH090E48B 9139055 14ACX-048-230 TXV 47,000 14.50 12.00 CH23-65 EL180UH090E60C 9139057 14ACX-048-230 TXV 47,000 14.25 11.70 CH23-65 EL180UH090XE48B 9139056 14ACX-048-230 TXV 46,500 14.50 12.00 CH23-65 EL180UH110E60C 9139046 14ACX-048-230 TXV 46,500 14.50 12.00 CH23-65 EL180UH110XE60C 9139047 14ACX-048-230 TXV 48,000 15.00 12.50 CH23-68 EL180UH135E60D 9139050 14ACX-048-230 TXV 48,000 14.50 12.00 CH23-68 EL195UH135XE60D 9139048 14ACX-048-230 TXV 48,000 14.50 12.00 CH23-68 EL296UH135XE60D 9139049 14ACX-048-230 TXV 48,000 14.00 11.70 CH23-68 9138607 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-43B EL180UH090E48B 9139051 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-43B EL180UH090XE48B 9139040 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-43C EL180UH090E60C 9139037 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-43C EL180UH110E60C 9139038 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-43C EL180UH110XE60C 9139039 14ACX-048-230 TXV 47,500 14.25 12.00 CH33-43C EL195UH090XE48C 9139041 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-43C EL195UH110XE60C 9139043 14ACX-048-230 TXV 47,500 14.25 12.00 CH33-43C EL296UH090XE48C 9139042 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-43C EL296UH090XV48C 9139045 14ACX-048-230 TXV 48,000 14.25 11.70 CH33-43C EL296UH090XV60C 9139034 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-43C EL296UH110XE60C 9139044 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-43C EL296UH110XV48C 9139035 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-43C EL296UH110XV60C 9139036 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 33 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-43C SL280UH090V60C 9139028 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-43C SL280UH090XV60C 9139029 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-43C SL280UH110V60C 9139030 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-43C SL280UH110XV60C 9139031 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-43C SLP98UH090XV48C 9139032 14ACX-048-230 TXV 48,000 14.25 11.70 CH33-43C SLP98UH090XV60C 9139033 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-43C SLP98UH110XV60C 9139022 14ACX-048-230 TXV 47,000 14.00 11.70 CH33-44/48B EL180UH090E48B 9139023 14ACX-048-230 TXV 47,000 14.00 11.70 CH33-44/48B EL180UH090XE48B 9139024 14ACX-048-230 TXV 47,500 14.50 12.00 CH33-48C EL180UH090E60C 9139021 14ACX-048-230 TXV 48,000 14.00 12.00 CH33-48C EL180UH110E60C 9139010 14ACX-048-230 TXV 48,000 14.00 12.00 CH33-48C EL180UH110XE60C 9139011 14ACX-048-230 TXV 47,500 14.00 12.00 CH33-48C EL195UH090XE48C 9139025 14ACX-048-230 TXV 47,500 14.00 12.00 CH33-48C EL195UH110XE60C 9139027 14ACX-048-230 TXV 47,500 14.00 12.00 CH33-48C EL296UH090XE48C 9139026 14ACX-048-230 TXV 47,500 14.00 11.70 CH33-48C EL296UH090XV48C 9139017 14ACX-048-230 TXV 47,500 14.00 11.70 CH33-48C EL296UH090XV60C 9139018 14ACX-048-230 TXV 47,500 14.00 12.00 CH33-48C EL296UH110XE60C 9139016 14ACX-048-230 TXV 47,500 14.25 11.70 CH33-48C EL296UH110XV48C 9139019 14ACX-048-230 TXV 47,500 14.00 11.70 CH33-48C EL296UH110XV60C 9139020 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-48C SL280UH090V60C 9139012 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-48C SL280UH090XV60C 9139013 14ACX-048-230 TXV 47,500 14.25 12.00 CH33-48C SL280UH110V60C 9139014 14ACX-048-230 TXV 47,500 14.25 12.00 CH33-48C SL280UH110XV60C 9139015 14ACX-048-230 TXV 47,500 14.00 11.70 CH33-48C SLP98UH090XV48C 9139004 14ACX-048-230 TXV 47,500 14.00 11.70 CH33-48C SLP98UH090XV60C 9139005 14ACX-048-230 TXV 47,500 14.00 11.70 CH33-48C SLP98UH110XV60C 9139006 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-49 EL180UH090E60C 9139003 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-49 EL180UH110E60C 9138992 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-49 EL180UH110XE60C 9138993 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-49 EL195UH090XE48C 9139007 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-49 EL195UH110XE60C 9139009 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-49 EL296UH090XE48C 9139008 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-49 EL296UH090XV48C 9138999 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-49 EL296UH090XV60C 9139000 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-49 EL296UH110XE60C 9138998 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-49 EL296UH110XV48C 9139001 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-49 EL296UH110XV60C 9139002 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-49 SL280UH090V60C 9138994 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-49 SL280UH090XV60C 9138995 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-49 SL280UH110V60C 9138996 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-49 SL280UH110XV60C 9138997 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-49 SLP98UH090XV48C 9138986 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-49 SLP98UH090XV60C 9138987 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-49 SLP98UH110XV60C 9138988 14ACX-048-230 TXV 48,000 14.00 11.70 CH33-49 9138608 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C EL180UH090E60C 9138985 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C EL180UH110E60C 9138974 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C EL180UH110XE60C 9138975 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 34 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C EL195UH090XE48C 9138989 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C EL195UH110XE60C 9138991 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C EL296UH090XE48C 9138990 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C EL296UH090XV48C 9138981 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C EL296UH090XV60C 9138982 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C EL296UH110XE60C 9138980 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C EL296UH110XV48C 9138983 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C EL296UH110XV60C 9138984 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C SL280UH090V60C 9138976 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C SL280UH090XV60C 9138977 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C SL280UH110V60C 9138978 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-50/60C SL280UH110XV60C 9138979 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C SLP98UH090XV48C 9138968 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C SLP98UH090XV60C 9138969 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-50/60C SLP98UH110XV60C 9138970 14ACX-048-230 TXV 48,000 14.00 11.70 CH33-50/60C 9138617 14ACX-048-230 TXV 48,000 15.00 12.50 CH33-60D EL180UH135E60D 9138962 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-60D EL195UH135XE60D 9138971 14ACX-048-230 TXV 48,000 14.25 12.00 CH33-60D EL296UH135XE60D 9138972 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-60D EL296UH135XV60D 9138973 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-60D SL280UH135V60D 9138963 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-60D SLP98UH135XV60D 9138964 14ACX-048-230 TXV 48,000 15.00 12.50 CH33-62D EL180UH135E60D 9138956 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-62D EL195UH135XE60D 9138965 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-62D EL296UH135XE60D 9138966 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-62D EL296UH135XV60D 9138967 14ACX-048-230 TXV 48,000 15.00 12.50 CH33-62D SL280UH135V60D 9138957 14ACX-048-230 TXV 48,000 14.50 12.00 CH33-62D SLP98UH135XV60D 9138958 14ACX-048-230 TXV 48,000 14.00 11.70 CH33-62D 9138618 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42B EL180UH090E48B 9138959 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42B EL180UH090XE48B 9138960 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42C EL180UH090E60C 9138945 14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C EL180UH110E60C 9138946 14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C EL180UH110XE60C 9138947 14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C EL195UH090XE48C 9138961 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42C EL195UH110XE60C 9138951 14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C EL296UH090XE48C 9138950 14ACX-048-230 TXV 48,000 14.25 11.70 CH35-42C EL296UH090XV48C 9138953 14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C EL296UH090XV60C 9138954 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42C EL296UH110XE60C 9138952 14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C EL296UH110XV48C 9138955 14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C EL296UH110XV60C 9138944 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42C SL280UH090V60C 9138948 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42C SL280UH090XV60C 9138949 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42C SL280UH110V60C 9138938 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-42C SL280UH110XV60C 9138939 14ACX-048-230 TXV 48,000 14.25 11.70 CH35-42C SLP98UH090XV48C 9138940 14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C SLP98UH090XV60C 9138941 14ACX-048-230 TXV 48,000 14.25 12.00 CH35-42C SLP98UH110XV60C 9138942 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 35 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-048-230 TXV 47,500 14.25 11.70 CH35-48B EL180UH090E48B 9138943 14ACX-048-230 TXV 47,500 14.25 11.70 CH35-48B EL180UH090XE48B 9138932 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-48C EL180UH090E60C 9138929 14ACX-048-230 TXV 48,000 14.25 11.70 CH35-48C EL180UH110E60C 9138930 14ACX-048-230 TXV 48,000 14.25 11.70 CH35-48C EL180UH110XE60C 9138931 14ACX-048-230 TXV 48,000 14.00 12.00 CH35-48C EL195UH090XE48C 9138933 14ACX-048-230 TXV 48,000 14.00 12.00 CH35-48C EL195UH110XE60C 9138935 14ACX-048-230 TXV 48,000 14.00 12.00 CH35-48C EL296UH090XE48C 9138934 14ACX-048-230 TXV 48,000 14.25 12.00 CH35-48C EL296UH090XV48C 9138937 14ACX-048-230 TXV 48,000 14.25 11.70 CH35-48C EL296UH090XV60C 9138926 14ACX-048-230 TXV 48,000 14.00 12.00 CH35-48C EL296UH110XE60C 9138936 14ACX-048-230 TXV 48,000 14.25 12.00 CH35-48C EL296UH110XV48C 9138927 14ACX-048-230 TXV 48,000 14.25 12.00 CH35-48C EL296UH110XV60C 9138928 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-48C SL280UH090V60C 9138920 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-48C SL280UH090XV60C 9138921 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-48C SL280UH110V60C 9138922 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-48C SL280UH110XV60C 9138923 14ACX-048-230 TXV 48,000 14.25 12.00 CH35-48C SLP98UH090XV48C 9138924 14ACX-048-230 TXV 48,000 14.25 11.70 CH35-48C SLP98UH090XV60C 9138925 14ACX-048-230 TXV 48,000 14.25 12.00 CH35-48C SLP98UH110XV60C 9138914 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C EL180UH090E60C 9138911 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C EL180UH110E60C 9138912 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C EL180UH110XE60C 9138913 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C EL195UH090XE48C 9138915 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C EL195UH110XE60C 9138917 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C EL296UH090XE48C 9138916 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C EL296UH090XV48C 9138919 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C EL296UH090XV60C 9138908 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C EL296UH110XE60C 9138918 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C EL296UH110XV48C 9138909 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C EL296UH110XV60C 9138910 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C SL280UH090V60C 9138902 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C SL280UH090XV60C 9138903 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C SL280UH110V60C 9138904 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C SL280UH110XV60C 9138905 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C SLP98UH090XV48C 9138906 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C SLP98UH090XV60C 9138907 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-51C SLP98UH110XV60C 9138896 14ACX-048-230 TXV 48,000 14.00 11.70 CH35-51C 9138619 14ACX-048-230 TXV 48,000 15.00 12.50 CH35-60D EL180UH135E60D 9138900 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-60D EL195UH135XE60D 9138897 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-60D EL296UH135XE60D 9138898 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-60D EL296UH135XV60D 9138899 14ACX-048-230 TXV 48,000 15.00 12.50 CH35-60D SL280UH135V60D 9138901 14ACX-048-230 TXV 48,000 14.50 12.00 CH35-60D SLP98UH135XV60D 9138890 14ACX-048-230 TXV 48,000 14.00 11.70 CH35-60D 9138620 14ACX-048-230 TXV 46,500 14.25 11.70 CR33-48 EL180DF110E60C 9138893 14ACX-048-230 TXV 46,500 14.00 11.70 CR33-48 EL195DF110XE60C 9138891 14ACX-048-230 TXV 46,500 14.00 11.70 CR33-48 EL296DF110XE60C 9138892 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 36 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-048-230 TXV 46,500 14.25 11.70 CR33-48 SL280DF090V60C 9138894 14ACX-048-230 TXV 46,500 14.25 11.70 CR33-48 SL280DF110V60C 9138895 14ACX-048-230 TXV 47,500 14.25 12.00 CR33-50/60 EL180DF110E60C 9138888 14ACX-048-230 TXV 47,000 14.25 12.00 CR33-50/60 EL195DF110XE60C 9138884 14ACX-048-230 TXV 47,000 14.00 11.70 CR33-50/60 EL296DF090XV60C 9138886 14ACX-048-230 TXV 47,000 14.25 12.00 CR33-50/60 EL296DF110XE60C 9138885 14ACX-048-230 TXV 47,000 14.00 11.70 CR33-50/60 EL296DF110XV60C 9138887 14ACX-048-230 TXV 47,000 14.25 12.00 CR33-50/60 SL280DF090V60C 9138889 14ACX-048-230 TXV 47,000 14.50 12.00 CR33-50/60 SL280DF110V60C 9138878 14ACX-048-230 TXV 47,000 14.00 11.70 CR33-50/60 SLP98DF090XV48C 9138879 14ACX-048-230 TXV 47,000 14.00 11.70 CR33-50/60 SLP98DF090XV60C 9138880 14ACX-048-230 TXV 47,000 14.00 11.70 CR33-50/60 SLP98DF110XV60C 9138881 14ACX-048-230 TXV 48,000 14.25 12.00 CX34-43B EL180UH090E48B 9138882 14ACX-048-230 TXV 48,000 14.25 12.00 CX34-43B EL180UH090XE48B 9138883 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-43C EL180UH090E60C 9138868 14ACX-048-230 TXV 47,500 14.50 12.00 CX34-43C EL180UH110E60C 9138869 14ACX-048-230 TXV 47,500 14.50 12.00 CX34-43C EL180UH110XE60C 9138870 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-43C EL195UH090XE48C 9138872 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-43C EL195UH110XE60C 9138874 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-43C EL296UH090XE48C 9138873 14ACX-048-230 TXV 48,000 14.25 12.00 CX34-43C EL296UH090XV48C 9138876 14ACX-048-230 TXV 48,000 14.25 12.00 CX34-43C EL296UH090XV60C 9138877 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-43C EL296UH110XE60C 9138875 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-43C EL296UH110XV48C 9138866 14ACX-048-230 TXV 48,000 14.25 12.00 CX34-43C EL296UH110XV60C 9138867 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-43C SL280UH090V60C 9138871 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-43C SL280UH090XV60C 9138860 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-43C SL280UH110V60C 9138861 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-43C SL280UH110XV60C 9138862 14ACX-048-230 TXV 48,000 14.25 12.00 CX34-43C SLP98UH090XV48C 9138863 14ACX-048-230 TXV 48,000 14.25 12.00 CX34-43C SLP98UH090XV60C 9138864 14ACX-048-230 TXV 48,000 14.25 12.00 CX34-43C SLP98UH110XV60C 9138865 14ACX-048-230 TXV 47,000 14.00 11.70 CX34-44/48B EL180UH090E48B 9138854 14ACX-048-230 TXV 47,000 14.00 11.70 CX34-44/48B EL180UH090XE48B 9138855 14ACX-048-230 TXV 46,500 14.25 11.70 CX34-44/48C EL180UH090E60C 9138850 14ACX-048-230 TXV 47,500 14.00 11.70 CX34-44/48C EL180UH110E60C 9138851 14ACX-048-230 TXV 47,500 14.00 11.70 CX34-44/48C EL180UH110XE60C 9138852 14ACX-048-230 TXV 46,500 14.00 11.70 CX34-44/48C EL195UH090XE48C 9138856 14ACX-048-230 TXV 46,500 14.00 11.70 CX34-44/48C EL195UH110XE60C 9138858 14ACX-048-230 TXV 46,500 14.00 11.70 CX34-44/48C EL296UH090XE48C 9138857 14ACX-048-230 TXV 47,000 14.00 11.70 CX34-44/48C EL296UH090XV48C 9138848 14ACX-048-230 TXV 46,500 14.00 11.70 CX34-44/48C EL296UH110XE60C 9138859 14ACX-048-230 TXV 47,000 14.00 11.70 CX34-44/48C EL296UH110XV48C 9138849 14ACX-048-230 TXV 47,000 14.25 11.70 CX34-44/48C SL280UH090V60C 9138853 14ACX-048-230 TXV 47,000 14.25 11.70 CX34-44/48C SL280UH090XV60C 9138842 14ACX-048-230 TXV 47,000 14.00 11.70 CX34-44/48C SL280UH110V60C 9138843 14ACX-048-230 TXV 47,000 14.00 11.70 CX34-44/48C SL280UH110XV60C 9138844 14ACX-048-230 TXV 47,000 14.00 11.70 CX34-44/48C SLP98UH090XV48C 9138845 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-49 EL180UH090E60C 9138830 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 37 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-048-230 TXV 48,000 15.00 12.00 CX34-49 EL180UH110E60C 9138831 14ACX-048-230 TXV 48,000 15.00 12.00 CX34-49 EL180UH110XE60C 9138832 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL195UH090XE48C 9138846 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL195UH110XE60C 9138836 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL296UH090XE48C 9138847 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL296UH090XV48C 9138838 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL296UH090XV60C 9138839 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL296UH110XE60C 9138837 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL296UH110XV48C 9138840 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 EL296UH110XV60C 9138841 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-49 SL280UH090V60C 9138833 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-49 SL280UH090XV60C 9138834 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-49 SL280UH110V60C 9138835 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-49 SL280UH110XV60C 9138824 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 SLP98UH090XV48C 9138825 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 SLP98UH090XV60C 9138826 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-49 SLP98UH110XV60C 9138827 14ACX-048-230 TXV 48,000 14.00 11.70 CX34-49 9138621 14ACX-048-230 TXV 47,500 14.50 12.00 CX34-50/60C EL180UH090E60C 9138812 14ACX-048-230 TXV 48,000 14.00 11.70 CX34-50/60C EL180UH110E60C 9138813 14ACX-048-230 TXV 48,000 14.00 11.70 CX34-50/60C EL180UH110XE60C 9138814 14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C EL195UH090XE48C 9138828 14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C EL195UH110XE60C 9138818 14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C EL296UH090XE48C 9138829 14ACX-048-230 TXV 47,500 14.00 11.70 CX34-50/60C EL296UH090XV48C 9138820 14ACX-048-230 TXV 47,500 14.00 11.70 CX34-50/60C EL296UH090XV60C 9138821 14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C EL296UH110XE60C 9138819 14ACX-048-230 TXV 47,500 14.25 11.70 CX34-50/60C EL296UH110XV48C 9138822 14ACX-048-230 TXV 47,500 14.00 11.70 CX34-50/60C EL296UH110XV60C 9138823 14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C SL280UH090V60C 9138815 14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C SL280UH090XV60C 9138816 14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C SL280UH110V60C 9138817 14ACX-048-230 TXV 47,500 14.25 12.00 CX34-50/60C SL280UH110XV60C 9138806 14ACX-048-230 TXV 47,500 14.00 11.70 CX34-50/60C SLP98UH090XV48C 9138807 14ACX-048-230 TXV 47,500 14.00 11.70 CX34-50/60C SLP98UH090XV60C 9138808 14ACX-048-230 TXV 47,500 14.00 11.70 CX34-50/60C SLP98UH110XV60C 9138809 14ACX-048-230 TXV 48,000 14.50 12.50 CX34-60D EL180UH135E60D 9138801 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-60D EL195UH135XE60D 9138810 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-60D EL296UH135XE60D 9138811 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-60D EL296UH135XV60D 9138800 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-60D SL280UH135V60D 9138802 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-60D SLP98UH135XV60D 9138803 14ACX-048-230 TXV 48,000 14.00 11.70 CX34-60D 9138622 14ACX-048-230 TXV 48,000 15.10 12.50 CX34-62C EL180UH090E60C 9139420 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-62C EL180UH110E60C 9138791 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-62C EL180UH110XE60C 9138792 14ACX-048-230 TXV 48,000 14.50 12.50 CX34-62C EL195UH090XE48C 9138804 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-62C EL195UH110XE60C 9138794 14ACX-048-230 TXV 48,000 14.50 12.50 CX34-62C EL296UH090XE48C 9138805 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 38 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-62C EL296UH090XV48C 9138796 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-62C EL296UH090XV60C 9138797 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-62C EL296UH110XE60C 9138795 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-62C EL296UH110XV48C 9138798 14ACX-048-230 TXV 48,000 14.50 12.50 CX34-62C EL296UH110XV60C 9138799 14ACX-048-230 TXV 48,000 15.10 12.50 CX34-62C SL280UH090V60C 9139421 14ACX-048-230 TXV 48,000 15.10 12.50 CX34-62C SL280UH090XV60C 9139422 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-62C SL280UH110V60C 9138793 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-62C SL280UH110XV60C 9138785 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-62C SLP98UH090XV48C 9138786 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-62C SLP98UH090XV60C 9138787 14ACX-048-230 TXV 48,000 14.50 12.50 CX34-62C SLP98UH110XV60C 9138788 14ACX-048-230 TXV 48,000 14.25 12.00 CX34-62C 9138611 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-62D EL180UH135E60D 9138790 14ACX-048-230 TXV 48,000 14.25 12.00 CX34-62D EL195UH135XE60D 9138623 14ACX-048-230 TXV 48,000 14.25 12.00 CX34-62D EL296UH135XE60D 9138789 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-62D EL296UH135XV60D 9138624 14ACX-048-230 TXV 48,000 15.00 12.50 CX34-62D SL280UH135V60D 9138779 14ACX-048-230 TXV 48,000 14.50 12.00 CX34-62D SLP98UH135XV60D 9138780 14ACX-048-230 TXV 48,000 14.00 11.70 CX34-62D 9138612 14ACX-048-230 TXV 48,000 14.25 12.00 CX35-48B EL180UH090E48B 9138708 14ACX-048-230 TXV 48,000 14.25 12.00 CX35-48B EL180UH090XE48B 9138709 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-48C EL180UH090E60C 9138688 14ACX-048-230 TXV 47,500 14.50 12.00 CX35-48C EL180UH110E60C 9138701 14ACX-048-230 TXV 47,500 14.50 12.00 CX35-48C EL180UH110XE60C 9138702 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-48C EL195UH090XE48C 9138689 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-48C EL195UH110XE60C 9138691 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-48C EL296UH090XE48C 9138690 14ACX-048-230 TXV 48,000 14.00 12.00 CX35-48C EL296UH090XV48C 9138696 14ACX-048-230 TXV 48,000 14.00 12.00 CX35-48C EL296UH090XV60C 9138697 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-48C EL296UH110XE60C 9138695 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-48C EL296UH110XV48C 9138686 14ACX-048-230 TXV 48,000 14.00 12.00 CX35-48C EL296UH110XV60C 9138687 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-48C SL280UH090V60C 9138703 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-48C SL280UH090XV60C 9138692 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-48C SL280UH110V60C 9138693 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-48C SL280UH110XV60C 9138694 14ACX-048-230 TXV 48,000 14.00 12.00 CX35-48C SLP98UH090XV48C 9138698 14ACX-048-230 TXV 48,000 14.00 12.00 CX35-48C SLP98UH090XV60C 9138699 14ACX-048-230 TXV 48,000 14.00 12.00 CX35-48C SLP98UH110XV60C 9138700 14ACX-048-230 TXV 48,000 15.00 12.50 CX35-49C EL180UH090E60C 9138678 14ACX-048-230 TXV 48,000 14.00 12.00 CX35-49C EL180UH110E60C 9138679 14ACX-048-230 TXV 48,000 14.00 12.00 CX35-49C EL180UH110XE60C 9138668 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-49C EL195UH090XE48C 9138669 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-49C EL195UH110XE60C 9138671 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-49C EL296UH090XE48C 9138670 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-49C EL296UH090XV48C 9138673 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-49C EL296UH090XV60C 9138675 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-49C EL296UH110XE60C 9138672 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 39 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-49C EL296UH110XV48C 9138676 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-49C EL296UH110XV60C 9138677 14ACX-048-230 TXV 48,000 15.00 12.50 CX35-49C SL280UH090V60C 9138681 14ACX-048-230 TXV 48,000 15.00 12.50 CX35-49C SL280UH090XV60C 9138682 14ACX-048-230 TXV 48,000 15.00 12.50 CX35-49C SL280UH110V60C 9138683 14ACX-048-230 TXV 48,000 15.00 12.50 CX35-49C SL280UH110XV60C 9138684 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-49C SLP98UH090XV48C 9138685 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-49C SLP98UH090XV60C 9138674 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-49C SLP98UH110XV60C 9138680 14ACX-048-230 TXV 48,000 14.00 11.70 CX35-49C 9138616 14ACX-048-230 TXV 47,500 14.50 12.00 CX35-50/60C EL180UH090E60C 9138660 14ACX-048-230 TXV 48,000 14.00 11.70 CX35-50/60C EL180UH110E60C 9138661 14ACX-048-230 TXV 48,000 14.00 11.70 CX35-50/60C EL180UH110XE60C 9138650 14ACX-048-230 TXV 47,500 14.25 12.00 CX35-50/60C EL195UH090XE48C 9138651 14ACX-048-230 TXV 47,500 14.25 12.00 CX35-50/60C EL195UH110XE60C 9138653 14ACX-048-230 TXV 47,500 14.25 12.00 CX35-50/60C EL296UH090XE48C 9138652 14ACX-048-230 TXV 47,500 14.00 11.70 CX35-50/60C EL296UH090XV48C 9138655 14ACX-048-230 TXV 47,500 14.00 11.70 CX35-50/60C EL296UH090XV60C 9138657 14ACX-048-230 TXV 47,500 14.25 12.00 CX35-50/60C EL296UH110XE60C 9138654 14ACX-048-230 TXV 47,500 14.25 11.70 CX35-50/60C EL296UH110XV48C 9138658 14ACX-048-230 TXV 47,500 14.00 11.70 CX35-50/60C EL296UH110XV60C 9138659 14ACX-048-230 TXV 47,500 14.25 12.00 CX35-50/60C SL280UH090V60C 9138663 14ACX-048-230 TXV 47,500 14.25 12.00 CX35-50/60C SL280UH090XV60C 9138664 14ACX-048-230 TXV 47,500 14.25 12.00 CX35-50/60C SL280UH110V60C 9138665 14ACX-048-230 TXV 47,500 14.25 12.00 CX35-50/60C SL280UH110XV60C 9138666 14ACX-048-230 TXV 47,500 14.00 11.70 CX35-50/60C SLP98UH090XV48C 9138667 14ACX-048-230 TXV 47,500 14.00 11.70 CX35-50/60C SLP98UH090XV60C 9138656 14ACX-048-230 TXV 47,500 14.00 11.70 CX35-50/60C SLP98UH110XV60C 9138662 14ACX-048-230 TXV 48,000 15.10 12.50 CX35-60C EL180UH090E60C 9139414 14ACX-048-230 TXV 48,000 15.00 12.50 CX35-60C EL180UH110E60C 9138645 14ACX-048-230 TXV 48,000 15.00 12.50 CX35-60C EL180UH110XE60C 9138635 14ACX-048-230 TXV 48,000 14.50 12.50 CX35-60C EL195UH090XE48C 9138636 14ACX-048-230 TXV 48,000 15.00 12.50 CX35-60C EL195UH110XE60C 9138638 14ACX-048-230 TXV 48,000 14.50 12.50 CX35-60C EL296UH090XE48C 9138637 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-60C EL296UH090XV48C 9138640 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-60C EL296UH090XV60C 9138642 14ACX-048-230 TXV 48,000 15.00 12.50 CX35-60C EL296UH110XE60C 9138639 14ACX-048-230 TXV 48,000 15.00 12.50 CX35-60C EL296UH110XV48C 9138643 14ACX-048-230 TXV 48,000 14.50 12.50 CX35-60C EL296UH110XV60C 9138644 14ACX-048-230 TXV 48,000 15.10 12.50 CX35-60C SL280UH090V60C 9139415 14ACX-048-230 TXV 48,000 15.10 12.50 CX35-60C SL280UH090XV60C 9139416 14ACX-048-230 TXV 48,000 15.00 12.50 CX35-60C SL280UH110V60C 9138647 14ACX-048-230 TXV 48,000 15.00 12.50 CX35-60C SL280UH110XV60C 9138648 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-60C SLP98UH090XV48C 9138649 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-60C SLP98UH090XV60C 9138641 14ACX-048-230 TXV 48,000 14.50 12.50 CX35-60C SLP98UH110XV60C 9138646 14ACX-048-230 TXV 48,000 14.00 11.70 CX35-60C 9138609 14ACX-048-230 TXV 48,000 15.00 12.50 CX35-60D EL180UH135E60D 9138633 14ACX-048-230 TXV 48,000 14.25 12.00 CX35-60D EL195UH135XE60D 9138630 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 40 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-048-230 TXV 48,000 14.25 12.00 CX35-60D EL296UH135XE60D 9138632 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-60D EL296UH135XV60D 9138631 14ACX-048-230 TXV 48,000 15.00 12.50 CX35-60D SL280UH135V60D 9138634 14ACX-048-230 TXV 48,000 14.50 12.00 CX35-60D SLP98UH135XV60D 9138629 14ACX-048-230 TXV 48,000 14.00 11.70 CX35-60D 9138610 14ACX-059-230 TXV 56,500 15.00 12.20 C33-49 EL180UH090E60C 9139316 14ACX-059-230 TXV 56,500 15.00 12.20 C33-49 EL180UH110E60C 9139322 14ACX-059-230 TXV 56,500 15.00 12.20 C33-49 EL180UH110XE60C 9139309 14ACX-059-230 TXV 56,500 14.70 12.20 C33-49 EL195UH110XE60C 9139405 14ACX-059-230 TXV 56,500 14.70 12.20 C33-49 EL296UH110XE60C 9139339 14ACX-059-230 TXV 56,500 14.70 12.00 C33-49 EL296UH110XV60C 9139352 14ACX-059-230 TXV 56,500 15.00 12.20 C33-49 SL280UH090V60C 9139375 14ACX-059-230 TXV 56,500 14.70 12.20 C33-49 SL280UH110V60C 9139400 14ACX-059-230 TXV 56,500 14.70 12.20 C33-49 SL280UH110XV60C 9139389 14ACX-059-230 TXV 57,000 14.50 12.00 C33-49 SLP98UH090XV60C 9139370 14ACX-059-230 TXV 56,500 14.70 12.00 C33-49 SLP98UH110XV60C 9139359 14ACX-059-230 TXV 57,000 14.50 12.00 C33-49 9139188 14ACX-059-230 TXV 56,000 14.00 11.70 C33-50/60C EL180UH110E60C 9139311 14ACX-059-230 TXV 55,500 14.50 12.00 C33-50/60C SL280UH090V60C 9139390 14ACX-059-230 TXV 55,500 14.20 12.00 C33-50/60C SL280UH110V60C 9139391 14ACX-059-230 TXV 55,500 14.20 12.00 C33-50/60C SL280UH110XV60C 9139392 14ACX-059-230 TXV 55,500 14.20 11.70 C33-50/60C SLP98UH110XV60C 9139360 14ACX-059-230 TXV 55,500 14.20 11.70 C33-50/60C 9139189 14ACX-059-230 TXV 57,000 15.00 12.20 C33-60D EL180UH135E60D 9139295 14ACX-059-230 TXV 56,500 14.20 12.00 C33-60D EL195UH135XE60D 9139398 14ACX-059-230 TXV 56,500 14.20 12.00 C33-60D EL296UH135XE60D 9139332 14ACX-059-230 TXV 57,000 15.00 12.20 C33-60D EL296UH135XV60D 9139341 14ACX-059-230 TXV 57,000 14.70 12.20 C33-60D SL280UH135V60D 9139412 14ACX-059-230 TXV 56,500 15.00 12.20 C33-60D SLP98UH135XV60D 9139357 14ACX-059-230 TXV 56,500 14.50 12.00 C33-60D 9139178 14ACX-059-230 TXV 58,000 15.50 12.70 C33-62C EL180UH090E60C 9139305 14ACX-059-230 TXV 57,500 15.20 12.50 C33-62C EL180UH110E60C 9139312 14ACX-059-230 TXV 57,500 15.20 12.50 C33-62C EL180UH110XE60C 9139301 14ACX-059-230 TXV 58,000 15.40 12.50 C33-62C EL195UH110XE60C 9139406 14ACX-059-230 TXV 58,000 15.40 12.50 C33-62C EL296UH110XE60C 9139340 14ACX-059-230 TXV 57,500 15.00 12.20 C33-62C EL296UH110XV60C 9139342 14ACX-059-230 TXV 58,000 15.20 12.50 C33-62C SL280UH090V60C 9139385 14ACX-059-230 TXV 58,000 14.70 12.20 C33-62C SL280UH110V60C 9139386 14ACX-059-230 TXV 58,000 14.70 12.20 C33-62C SL280UH110XV60C 9139387 14ACX-059-230 TXV 58,000 14.70 12.20 C33-62C SLP98UH090XV60C 9139353 14ACX-059-230 TXV 57,500 15.00 12.20 C33-62C SLP98UH110XV60C 9139354 14ACX-059-230 TXV 57,500 14.70 12.20 C33-62C 9139185 14ACX-059-230 TXV 57,500 15.10 12.50 C33-62D EL180UH135E60D 9139296 14ACX-059-230 TXV 57,500 14.50 12.20 C33-62D EL195UH135XE60D 9139369 14ACX-059-230 TXV 57,500 14.50 12.20 C33-62D EL296UH135XE60D 9139327 14ACX-059-230 TXV 57,500 15.00 12.50 C33-62D EL296UH135XV60D 9139336 14ACX-059-230 TXV 57,000 15.50 12.70 C33-62D SL280UH135V60D 9139388 14ACX-059-230 TXV 57,000 14.50 12.00 C33-62D 9139186 14ACX-059-230 TXV 56,000 14.00 12.20 C35-48C EL180UH090E60C 9139278 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 41 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-059-230 TXV 56,000 14.00 12.20 C35-48C EL180UH110E60C 9139279 14ACX-059-230 TXV 56,000 14.50 12.20 C35-48C EL195UH110XE60C 9139280 14ACX-059-230 TXV 56,000 14.50 12.20 C35-48C EL296UH110XE60C 9139270 14ACX-059-230 TXV 56,000 14.50 12.00 C35-48C EL296UH110XV60C 9139269 14ACX-059-230 TXV 56,000 14.50 12.20 C35-48C SL280UH090V60C 9139271 14ACX-059-230 TXV 56,000 14.50 12.20 C35-48C SL280UH110V60C 9139272 14ACX-059-230 TXV 56,000 14.50 12.20 C35-48C SL280UH110XV60C 9139273 14ACX-059-230 TXV 56,000 14.00 11.70 C35-48C SLP98UH090XV60C 9139274 14ACX-059-230 TXV 56,000 14.20 11.70 C35-48C SLP98UH110XV60C 9139263 14ACX-059-230 TXV 56,000 14.00 11.70 C35-48C 9139183 14ACX-059-230 TXV 56,500 15.00 12.20 C35-49C EL180UH090E60C 9139213 14ACX-059-230 TXV 56,500 15.00 12.20 C35-49C EL180UH110E60C 9139214 14ACX-059-230 TXV 56,500 14.50 12.20 C35-49C EL195UH110XE60C 9139203 14ACX-059-230 TXV 56,500 14.50 12.20 C35-49C EL296UH110XE60C 9139205 14ACX-059-230 TXV 56,500 14.50 12.00 C35-49C EL296UH110XV60C 9139204 14ACX-059-230 TXV 56,500 15.00 12.20 C35-49C SL280UH090V60C 9139206 14ACX-059-230 TXV 56,500 14.50 12.20 C35-49C SL280UH110V60C 9139207 14ACX-059-230 TXV 56,500 14.50 12.20 C35-49C SL280UH110XV60C 9139208 14ACX-059-230 TXV 57,000 14.20 12.20 C35-49C SLP98UH090XV60C 9139197 14ACX-059-230 TXV 56,500 14.50 12.00 C35-49C SLP98UH110XV60C 9139198 14ACX-059-230 TXV 57,000 14.50 12.00 C35-49C 9139170 14ACX-059-230 TXV 56,500 14.00 11.70 C35-50/60C EL180UH090E60C 9139264 14ACX-059-230 TXV 56,000 14.00 11.70 C35-50/60C EL180UH110E60C 9139265 14ACX-059-230 TXV 55,500 14.20 11.70 C35-50/60C SL280UH090V60C 9139266 14ACX-059-230 TXV 55,500 14.20 12.00 C35-50/60C SL280UH110V60C 9139267 14ACX-059-230 TXV 55,500 14.20 12.00 C35-50/60C SL280UH110XV60C 9139268 14ACX-059-230 TXV 55,500 14.20 11.70 C35-50/60C SLP98UH110XV60C 9139257 14ACX-059-230 TXV 55,500 14.20 11.70 C35-50/60C 9139172 14ACX-059-230 TXV 58,000 15.50 12.50 C35-60C EL180UH090E60C 9139258 14ACX-059-230 TXV 57,500 15.10 12.50 C35-60C EL180UH110XE60C 9139259 14ACX-059-230 TXV 57,000 14.50 12.20 C35-60C EL195UH110XE60C 9139260 14ACX-059-230 TXV 57,000 14.50 12.20 C35-60C EL296UH110XE60C 9139262 14ACX-059-230 TXV 58,000 14.50 12.20 C35-60C EL296UH110XV60C 9139261 14ACX-059-230 TXV 58,000 15.10 12.50 C35-60C SL280UH090V60C 9139251 14ACX-059-230 TXV 58,000 14.50 12.20 C35-60C SL280UH110V60C 9139252 14ACX-059-230 TXV 58,000 14.50 12.20 C35-60C SL280UH110XV60C 9139253 14ACX-059-230 TXV 58,000 14.50 12.20 C35-60C SLP98UH090XV60C 9139254 14ACX-059-230 TXV 57,500 15.00 12.20 C35-60C SLP98UH110XV60C 9139255 14ACX-059-230 TXV 57,500 14.50 12.20 C35-60C 9139173 14ACX-059-230 TXV 56,500 15.50 12.50 C35-60D EL180UH135E60D 9139256 14ACX-059-230 TXV 57,500 14.50 12.20 C35-60D EL195UH135XE60D 9139245 14ACX-059-230 TXV 57,500 14.50 12.20 C35-60D EL296UH135XE60D 9139247 14ACX-059-230 TXV 57,500 15.00 12.20 C35-60D EL296UH135XV60D 9139246 14ACX-059-230 TXV 57,000 15.50 12.50 C35-60D SL280UH135V60D 9139248 14ACX-059-230 TXV 57,000 14.50 11.70 C35-60D 9139174 14ACX-059-230 TXV 56,000 15.00 12.00 CBA27UHE-060 10259385 14ACX-059-230 TXV 56,500 14.50 12.00 CBX25UH-060 9139328 14ACX-059-230 TXV 57,000 15.00 12.50 CBX25UHV-060 9139298 14ACX-059-230 TXV 56,500 15.00 12.20 CBX27UH-060 9139408 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 42 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-059-230 TXV 56,500 14.50 12.20 CBX32M-060 9139409 14ACX-059-230 TXV 55,500 14.70 12.00 CBX32MV-048 9139410 14ACX-059-230 TXV 56,500 14.70 12.20 CBX32MV-060 9139411 14ACX-059-230 TXV 56,000 14.70 12.00 CBX32MV-068 9139190 14ACX-059-230 TXV 56,000 15.00 12.20 CBX40UHV-048 9139191 14ACX-059-230 TXV 56,500 14.70 12.20 CBX40UHV-060 9139192 14ACX-059-230 TXV 57,500 15.20 12.50 CH23-68 EL180UH135E60D 9139297 14ACX-059-230 TXV 57,500 14.70 12.20 CH23-68 EL195UH135XE60D 9139399 14ACX-059-230 TXV 57,500 14.70 12.20 CH23-68 EL296UH135XE60D 9139333 14ACX-059-230 TXV 57,000 14.50 12.50 CH23-68 9139164 14ACX-059-230 TXV 57,000 15.00 12.50 CH33-49 EL180UH090E60C 9139306 14ACX-059-230 TXV 56,500 15.00 12.20 CH33-49 EL180UH110E60C 9139308 14ACX-059-230 TXV 56,500 15.00 12.20 CH33-49 EL180UH110XE60C 9139310 14ACX-059-230 TXV 56,500 15.00 12.20 CH33-49 EL195UH110XE60C 9139395 14ACX-059-230 TXV 56,500 15.00 12.20 CH33-49 EL296UH110XE60C 9139329 14ACX-059-230 TXV 57,000 15.00 12.20 CH33-49 SL280UH090V60C 9139193 14ACX-059-230 TXV 57,000 14.70 12.00 CH33-49 SL280UH110V60C 9139194 14ACX-059-230 TXV 57,000 14.70 12.00 CH33-49 SL280UH110XV60C 9139401 14ACX-059-230 TXV 57,000 14.50 12.00 CH33-49 SLP98UH090XV60C 9139358 14ACX-059-230 TXV 57,500 14.20 11.70 CH33-50/60C EL180UH090E60C 9139307 14ACX-059-230 TXV 57,500 14.20 12.00 CH33-50/60C EL180UH110E60C 9139318 14ACX-059-230 TXV 57,500 14.20 12.00 CH33-50/60C EL180UH110XE60C 9139302 14ACX-059-230 TXV 57,000 14.20 11.70 CH33-50/60C EL195UH110XE60C 9139396 14ACX-059-230 TXV 57,000 14.20 11.70 CH33-50/60C EL296UH110XE60C 9139330 14ACX-059-230 TXV 56,500 14.50 12.00 CH33-50/60C SL280UH090V60C 9139402 14ACX-059-230 TXV 56,000 14.50 12.00 CH33-50/60C SL280UH110V60C 9139403 14ACX-059-230 TXV 56,000 14.50 12.00 CH33-50/60C SL280UH110XV60C 9139377 14ACX-059-230 TXV 56,500 15.00 12.20 CH33-60D EL180UH135E60D 9139303 14ACX-059-230 TXV 56,500 14.50 12.00 CH33-60D EL195UH135XE60D 9139376 14ACX-059-230 TXV 56,500 14.50 12.00 CH33-60D EL296UH135XE60D 9139334 14ACX-059-230 TXV 56,500 14.70 12.20 CH33-60D EL296UH135XV60D 9139346 14ACX-059-230 TXV 56,500 14.70 12.20 CH33-60D SL280UH135V60D 9139393 14ACX-059-230 TXV 56,500 14.70 12.20 CH33-60D SLP98UH135XV60D 9139361 14ACX-059-230 TXV 56,000 14.50 11.70 CH33-60D 9139179 14ACX-059-230 TXV 57,000 15.00 12.20 CH33-62D EL180UH135E60D 9139304 14ACX-059-230 TXV 57,000 14.50 12.00 CH33-62D EL195UH135XE60D 9139365 14ACX-059-230 TXV 57,000 14.50 12.00 CH33-62D EL296UH135XE60D 9139323 14ACX-059-230 TXV 57,000 15.00 12.20 CH33-62D EL296UH135XV60D 9139335 14ACX-059-230 TXV 57,000 14.70 12.20 CH33-62D SL280UH135V60D 9139394 14ACX-059-230 TXV 56,500 15.00 12.20 CH33-62D SLP98UH135XV60D 9139362 14ACX-059-230 TXV 56,500 14.50 12.00 CH33-62D 9139180 14ACX-059-230 TXV 58,000 14.50 12.00 CH35-51C EL180UH090E60C 9139291 14ACX-059-230 TXV 58,000 14.50 12.00 CH35-51C EL180UH110E60C 9139292 14ACX-059-230 TXV 57,500 14.25 11.70 CH35-51C EL195UH110XE60C 9139289 14ACX-059-230 TXV 57,500 14.25 11.70 CH35-51C EL296UH110XE60C 9139290 14ACX-059-230 TXV 57,500 14.50 12.00 CH35-51C SL280UH090V60C 9139281 14ACX-059-230 TXV 56,500 14.50 12.00 CH35-51C SL280UH110V60C 9139282 14ACX-059-230 TXV 56,500 14.50 12.00 CH35-51C SL280UH110XV60C 9139283 14ACX-059-230 TXV 57,000 14.50 12.00 CH35-51C SLP98UH090XV60C 9139288 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 43 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-059-230 TXV 57,000 14.50 12.00 CH35-51C SLP98UH110XV60C 9139287 14ACX-059-230 TXV 57,000 14.50 12.00 CH35-51C 9139181 14ACX-059-230 TXV 57,000 15.00 12.00 CH35-60D EL180UH135E60D 9139275 14ACX-059-230 TXV 57,000 14.50 12.00 CH35-60D EL195UH135XE60D 9139284 14ACX-059-230 TXV 57,000 14.50 12.00 CH35-60D EL296UH135XE60D 9139286 14ACX-059-230 TXV 57,000 15.00 12.00 CH35-60D EL296UH135XV60D 9139285 14ACX-059-230 TXV 57,000 15.00 12.00 CH35-60D SL280UH135V60D 9139276 14ACX-059-230 TXV 57,000 15.00 12.00 CH35-60D SLP98UH135XV60D 9139277 14ACX-059-230 TXV 56,500 14.50 12.00 CH35-60D 9139182 14ACX-059-230 TXV 56,000 15.00 12.20 CR33-50/60 EL180DF110E60C 9139317 14ACX-059-230 TXV 55,500 14.50 12.00 CR33-50/60 EL195DF110XE60C 9139404 14ACX-059-230 TXV 55,500 14.50 12.00 CR33-50/60 EL296DF110XE60C 9139338 14ACX-059-230 TXV 55,500 14.70 12.00 CR33-50/60 SL280DF090V60C 9139383 14ACX-059-230 TXV 56,000 14.70 12.20 CR33-50/60 SL280DF110V60C 9139384 14ACX-059-230 TXV 56,500 14.20 11.70 CR33-50/60 SLP98DF090XV60C 9139363 14ACX-059-230 TXV 55,500 14.20 11.70 CR33-50/60 SLP98DF110XV60C 9139364 14ACX-059-230 TXV 55,500 14.20 11.70 CR33-50/60 9139184 14ACX-059-230 TXV 55,500 14.20 11.70 CR33-60 9139165 14ACX-059-230 TXV 56,500 15.00 12.20 CX34-49 EL180UH090E60C 9139313 14ACX-059-230 TXV 56,500 15.00 12.20 CX34-49 EL180UH110E60C 9139319 14ACX-059-230 TXV 56,500 15.00 12.20 CX34-49 EL180UH110XE60C 9139299 14ACX-059-230 TXV 56,500 14.70 12.20 CX34-49 EL195UH110XE60C 9139397 14ACX-059-230 TXV 56,500 14.70 12.20 CX34-49 EL296UH110XE60C 9139331 14ACX-059-230 TXV 56,500 14.70 12.00 CX34-49 EL296UH110XV60C 9139343 14ACX-059-230 TXV 56,500 15.00 12.20 CX34-49 SL280UH090V60C 9139379 14ACX-059-230 TXV 56,500 14.70 12.20 CX34-49 SL280UH110V60C 9139380 14ACX-059-230 TXV 56,500 14.70 12.20 CX34-49 SL280UH110XV60C 9139381 14ACX-059-230 TXV 57,000 14.70 12.00 CX34-49 SLP98UH090XV60C 9139351 14ACX-059-230 TXV 56,500 14.70 12.00 CX34-49 SLP98UH110XV60C 9139347 14ACX-059-230 TXV 57,000 14.50 12.00 CX34-49 9139166 14ACX-059-230 TXV 56,500 14.00 11.70 CX34-50/60C EL180UH090E60C 9139314 14ACX-059-230 TXV 56,000 14.00 11.70 CX34-50/60C EL180UH110E60C 9139320 14ACX-059-230 TXV 55,500 14.20 11.70 CX34-50/60C SL280UH090V60C 9139382 14ACX-059-230 TXV 55,500 14.20 12.00 CX34-50/60C SL280UH110V60C 9139371 14ACX-059-230 TXV 55,500 14.20 12.00 CX34-50/60C SL280UH110XV60C 9139372 14ACX-059-230 TXV 55,500 14.00 11.70 CX34-50/60C SLP98UH090XV60C 9139348 14ACX-059-230 TXV 55,500 14.20 11.70 CX34-50/60C SLP98UH110XV60C 9139349 14ACX-059-230 TXV 55,500 14.20 11.70 CX34-50/60C 9139167 14ACX-059-230 TXV 57,000 15.00 12.20 CX34-60D EL180UH135E60D 9139293 14ACX-059-230 TXV 56,500 14.70 12.00 CX34-60D EL195UH135XE60D 9139366 14ACX-059-230 TXV 56,500 14.70 12.00 CX34-60D EL296UH135XE60D 9139324 14ACX-059-230 TXV 57,000 15.00 12.20 CX34-60D EL296UH135XV60D 9139344 14ACX-059-230 TXV 57,000 14.70 12.20 CX34-60D SL280UH135V60D 9139373 14ACX-059-230 TXV 56,500 15.00 12.20 CX34-60D SLP98UH135XV60D 9139350 14ACX-059-230 TXV 56,500 14.50 12.00 CX34-60D 9139168 14ACX-059-230 TXV 58,000 15.50 12.70 CX34-62C EL180UH090E60C 9139315 14ACX-059-230 TXV 57,500 15.20 12.50 CX34-62C EL180UH110E60C 9139321 14ACX-059-230 TXV 57,500 15.20 12.50 CX34-62C EL180UH110XE60C 9139300 14ACX-059-230 TXV 57,000 14.50 12.20 CX34-62C EL195UH110XE60C 9139368 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 44 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-059-230 TXV 57,000 14.50 12.20 CX34-62C EL296UH110XE60C 9139326 14ACX-059-230 TXV 57,500 15.00 12.20 CX34-62C EL296UH110XV60C 9139345 14ACX-059-230 TXV 58,000 15.10 12.50 CX34-62C SL280UH090V60C 9139378 14ACX-059-230 TXV 58,000 14.70 12.20 CX34-62C SL280UH110V60C 9139195 14ACX-059-230 TXV 58,000 14.70 12.20 CX34-62C SL280UH110XV60C 9139407 14ACX-059-230 TXV 58,000 14.70 12.20 CX34-62C SLP98UH090XV60C 9139355 14ACX-059-230 TXV 57,500 15.00 12.20 CX34-62C SLP98UH110XV60C 9139356 14ACX-059-230 TXV 57,500 14.70 12.20 CX34-62C 9139163 14ACX-059-230 TXV 57,500 15.20 12.50 CX34-62D EL180UH135E60D 9139294 14ACX-059-230 TXV 57,500 15.00 12.20 CX34-62D EL195UH135XE60D 9139367 14ACX-059-230 TXV 57,500 15.00 12.20 CX34-62D EL296UH135XE60D 9139325 14ACX-059-230 TXV 57,500 15.00 12.50 CX34-62D EL296UH135XV60D 9139337 14ACX-059-230 TXV 57,000 15.50 12.70 CX34-62D SL280UH135V60D 9139374 14ACX-059-230 TXV 57,000 14.70 11.70 CX34-62D 9139187 14ACX-059-230 TXV 56,000 14.00 12.20 CX35-48C EL180UH090E60C 9139249 14ACX-059-230 TXV 56,000 14.00 12.20 CX35-48C EL180UH110E60C 9139250 14ACX-059-230 TXV 56,000 14.50 12.20 CX35-48C EL195UH110XE60C 9139239 14ACX-059-230 TXV 56,000 14.50 12.20 CX35-48C EL296UH110XE60C 9139241 14ACX-059-230 TXV 56,000 14.50 12.00 CX35-48C EL296UH110XV60C 9139240 14ACX-059-230 TXV 56,000 14.50 12.20 CX35-48C SL280UH090V60C 9139242 14ACX-059-230 TXV 56,000 14.50 12.00 CX35-48C SL280UH110V60C 9139243 14ACX-059-230 TXV 56,000 14.50 12.20 CX35-48C SL280UH110XV60C 9139244 14ACX-059-230 TXV 56,000 14.00 11.70 CX35-48C SLP98UH090XV60C 9139233 14ACX-059-230 TXV 56,000 14.20 12.20 CX35-48C SLP98UH110XV60C 9139234 14ACX-059-230 TXV 56,000 14.20 11.70 CX35-48C 9139175 14ACX-059-230 TXV 56,500 15.00 12.20 CX35-49C EL180UH090E60C 9139235 14ACX-059-230 TXV 56,500 15.00 12.20 CX35-49C EL180UH110E60C 9139236 14ACX-059-230 TXV 56,500 14.50 12.20 CX35-49C EL195UH110XE60C 9139237 14ACX-059-230 TXV 56,500 14.50 12.20 CX35-49C EL296UH110XE60C 9139227 14ACX-059-230 TXV 56,500 14.50 12.00 CX35-49C EL296UH110XV60C 9139238 14ACX-059-230 TXV 56,500 15.00 12.20 CX35-49C SL280UH090V60C 9139228 14ACX-059-230 TXV 56,500 14.50 12.20 CX35-49C SL280UH110V60C 9139229 14ACX-059-230 TXV 56,500 14.50 12.20 CX35-49C SL280UH110XV60C 9139230 14ACX-059-230 TXV 57,000 14.20 12.20 CX35-49C SLP98UH090XV60C 9139231 14ACX-059-230 TXV 56,500 14.50 12.00 CX35-49C SLP98UH110XV60C 9139232 14ACX-059-230 TXV 57,000 14.50 12.00 CX35-49C 9139176 14ACX-059-230 TXV 56,500 14.00 11.70 CX35-50/60C EL180UH090E60C 9139221 14ACX-059-230 TXV 56,000 14.00 11.70 CX35-50/60C EL180UH110E60C 9139222 14ACX-059-230 TXV 55,500 14.20 11.70 CX35-50/60C SL280UH090V60C 9139223 14ACX-059-230 TXV 55,500 14.20 12.00 CX35-50/60C SL280UH110V60C 9139224 14ACX-059-230 TXV 55,500 14.20 12.00 CX35-50/60C SL280UH110XV60C 9139225 14ACX-059-230 TXV 55,500 14.20 11.70 CX35-50/60C SLP98UH110XV60C 9139226 14ACX-059-230 TXV 55,500 14.20 11.70 CX35-50/60C 9139177 14ACX-059-230 TXV 58,000 15.50 12.50 CX35-60C EL180UH090E60C 9139215 14ACX-059-230 TXV 57,500 15.10 12.50 CX35-60C EL180UH110E60C 9139216 14ACX-059-230 TXV 57,000 14.50 12.20 CX35-60C EL195UH110XE60C 9139217 14ACX-059-230 TXV 57,000 14.50 12.20 CX35-60C EL296UH110XE60C 9139219 14ACX-059-230 TXV 58,000 14.50 12.20 CX35-60C EL296UH110XV60C 9139218 14ACX-059-230 TXV 58,000 15.10 12.50 CX35-60C SL280UH090V60C 9139220 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 45 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-059-230 TXV 58,000 14.50 12.20 CX35-60C SL280UH110V60C 9139209 14ACX-059-230 TXV 58,000 14.50 12.20 CX35-60C SL280UH110XV60C 9139210 14ACX-059-230 TXV 58,000 14.50 12.20 CX35-60C SLP98UH090XV60C 9139211 14ACX-059-230 TXV 57,500 15.00 12.20 CX35-60C SLP98UH110XV60C 9139212 14ACX-059-230 TXV 57,500 14.50 12.20 CX35-60C 9139169 14ACX-059-230 TXV 56,500 15.50 12.50 CX35-60D EL180UH135E60D 9139199 14ACX-059-230 TXV 57,500 14.50 12.20 CX35-60D EL195UH135XE60D 9139200 14ACX-059-230 TXV 57,500 14.50 12.20 CX35-60D EL296UH135XE60D 9139202 14ACX-059-230 TXV 57,500 15.00 12.20 CX35-60D EL296UH135XV60D 9139201 14ACX-059-230 TXV 57,000 15.50 12.50 CX35-60D SL280UH135V60D 9139196 14ACX-059-230 TXV 57,000 14.50 11.70 CX35-60D 9139171 14ACX-060-230 TXV 58,000 14.50 12.00 C33-49 EL180UH090E60C 5736959 14ACX-060-230 TXV 57,500 14.20 12.00 C33-49 EL180UH110E60C 5738738 14ACX-060-230 TXV 57,500 14.20 12.00 C33-49 EL180UH110XE60C 5739577 14ACX-060-230 TXV 57,500 14.20 12.00 C33-49 EL195UH110XE60C 5697671 14ACX-060-230 TXV 57,000 14.20 11.70 C33-49 EL296UH090XV60C 5699645 14ACX-060-230 TXV 57,500 14.20 12.00 C33-49 EL296UH110XE60C 5697672 14ACX-060-230 TXV 57,000 14.20 12.00 C33-49 EL296UH110XV60C 5699646 14ACX-060-230 TXV 58,000 14.20 12.00 C33-49 SL280UH090V60C 5697678 14ACX-060-230 TXV 58,000 14.20 12.00 C33-49 SL280UH090XV60C 5697680 14ACX-060-230 TXV 57,500 14.20 12.00 C33-49 SL280UH110V60C 5697679 14ACX-060-230 TXV 57,500 14.20 12.00 C33-49 SL280UH110XV60C 5697681 14ACX-060-230 TXV 57,000 14.20 11.70 C33-49 SLP98UH090XV60C 5697673 14ACX-060-230 TXV 57,000 14.20 12.00 C33-49 SLP98UH110XV60C 5697674 14ACX-060-230 TXV 58,000 14.00 11.70 C33-49 5697670 14ACX-060-230 TXV 56,500 14.20 11.70 C33-50/60C EL180UH090E60C 5736961 14ACX-060-230 TXV 56,500 14.00 11.70 C33-50/60C EL180UH110E60C 5738740 14ACX-060-230 TXV 56,500 14.00 11.70 C33-50/60C EL180UH110XE60C 5739579 14ACX-060-230 TXV 56,500 14.00 11.70 C33-50/60C EL195UH110XE60C 5697683 14ACX-060-230 TXV 56,500 14.00 11.70 C33-50/60C EL296UH110XE60C 5697684 14ACX-060-230 TXV 56,500 14.00 11.70 C33-50/60C SL280UH090V60C 5697689 14ACX-060-230 TXV 56,500 14.00 11.70 C33-50/60C SL280UH090XV60C 5697691 14ACX-060-230 TXV 58,000 14.50 12.00 C33-60D EL180UH135E60D 5745978 14ACX-060-230 TXV 58,000 14.00 11.70 C33-60D EL195UH135XE60D 5697696 14ACX-060-230 TXV 58,000 14.00 11.70 C33-60D EL296UH135XE60D 5697697 14ACX-060-230 TXV 57,500 14.50 12.00 C33-60D EL296UH135XV60D 5697698 14ACX-060-230 TXV 57,500 14.70 12.20 C33-60D SL280UH135V60D 5697700 14ACX-060-230 TXV 57,500 14.50 12.00 C33-60D SLP98UH135XV60D 5697701 14ACX-060-230 TXV 57,500 14.00 11.70 C33-60D 5697695 14ACX-060-230 TXV 59,000 14.70 12.20 C33-62C EL180UH090E60C 5736957 14ACX-060-230 TXV 58,500 14.70 12.20 C33-62C EL180UH110E60C 5738736 14ACX-060-230 TXV 58,500 14.70 12.20 C33-62C EL180UH110XE60C 5739575 14ACX-060-230 TXV 58,500 14.50 12.00 C33-62C EL195UH110XE60C 5697703 14ACX-060-230 TXV 58,000 14.50 12.00 C33-62C EL296UH090XV60C 5697705 14ACX-060-230 TXV 58,500 14.50 12.00 C33-62C EL296UH110XE60C 5697704 14ACX-060-230 TXV 58,000 14.50 12.20 C33-62C EL296UH110XV60C 5697706 14ACX-060-230 TXV 59,000 14.70 12.20 C33-62C SL280UH090V60C 5697710 14ACX-060-230 TXV 59,000 14.70 12.20 C33-62C SL280UH090XV60C 5697712 14ACX-060-230 TXV 58,500 14.50 12.20 C33-62C SL280UH110V60C 5697711 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 46 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-060-230 TXV 58,500 14.50 12.20 C33-62C SL280UH110XV60C 5697713 14ACX-060-230 TXV 58,500 14.50 12.00 C33-62C SLO185B124/141V60 7110043 14ACX-060-230 TXV 58,000 14.50 12.00 C33-62C SLP98UH090XV60C 5697714 14ACX-060-230 TXV 58,000 14.50 12.20 C33-62C SLP98UH110XV60C 5697715 14ACX-060-230 TXV 59,000 14.20 12.00 C33-62C 5697702 14ACX-060-230 TXV 58,500 14.50 12.20 C33-62D EL180UH135E60D 5745979 14ACX-060-230 TXV 58,500 14.20 11.70 C33-62D EL195UH135XE60D 5697717 14ACX-060-230 TXV 58,500 14.20 11.70 C33-62D EL296UH135XE60D 5697718 14ACX-060-230 TXV 57,500 14.50 12.00 C33-62D EL296UH135XV60D 5697719 14ACX-060-230 TXV 58,000 15.00 12.20 C33-62D SL280UH135V60D 5697721 14ACX-060-230 TXV 57,500 14.50 12.00 C33-62D SLP98UH135XV60D 5697722 14ACX-060-230 TXV 58,500 14.00 11.70 C33-62D 5697716 14ACX-060-230 TXV 58,000 14.50 12.00 C35-49C EL180UH090E60C 8267315 14ACX-060-230 TXV 57,500 14.20 12.00 C35-49C EL180UH110E60C 8267317 14ACX-060-230 TXV 57,500 14.20 12.00 C35-49C EL180UH110XE60C 8267314 14ACX-060-230 TXV 57,500 14.20 12.00 C35-49C EL195UH110XE60C 8267308 14ACX-060-230 TXV 57,000 14.20 11.70 C35-49C EL296UH090XV60C 8267318 14ACX-060-230 TXV 57,500 14.20 12.00 C35-49C EL296UH110XE60C 8267309 14ACX-060-230 TXV 57,000 14.20 12.00 C35-49C EL296UH110XV60C 8267316 14ACX-060-230 TXV 58,000 14.20 12.00 C35-49C SL280UH090V60C 8267312 14ACX-060-230 TXV 58,000 14.20 12.00 C35-49C SL280UH090XV60C 8267319 14ACX-060-230 TXV 57,500 14.20 12.00 C35-49C SL280UH110V60C 8267313 14ACX-060-230 TXV 57,500 14.20 12.00 C35-49C SL280UH110XV60C 8267320 14ACX-060-230 TXV 57,000 14.20 11.70 C35-49C SLP98UH090XV60C 8267310 14ACX-060-230 TXV 57,000 14.20 12.00 C35-49C SLP98UH110XV60C 8267311 14ACX-060-230 TXV 58,000 14.00 11.70 C35-49C 8267307 14ACX-060-230 TXV 56,500 14.20 11.70 C35-50/60C EL180UH090E60C 8267323 14ACX-060-230 TXV 56,500 14.00 11.70 C35-50/60C EL180UH110E60C 8267322 14ACX-060-230 TXV 56,500 14.00 11.70 C35-50/60C EL180UH110XE60C 8267321 14ACX-060-230 TXV 56,500 14.00 11.70 C35-50/60C EL195UH110XE60C 8267324 14ACX-060-230 TXV 56,500 14.00 11.70 C35-50/60C EL296UH110XE60C 8267325 14ACX-060-230 TXV 56,500 14.00 11.70 C35-50/60C SL280UH090V60C 8267326 14ACX-060-230 TXV 56,500 14.00 11.70 C35-50/60C SL280UH090XV60C 8267327 14ACX-060-230 TXV 59,000 14.70 12.20 C35-60C EL180UH090E60C 8267332 14ACX-060-230 TXV 58,500 14.70 12.20 C35-60C EL180UH110E60C 8267331 14ACX-060-230 TXV 58,500 14.70 12.20 C35-60C EL180UH110XE60C 8267330 14ACX-060-230 TXV 58,500 14.50 12.00 C35-60C EL195UH110XE60C 8267341 14ACX-060-230 TXV 58,000 14.50 12.00 C35-60C EL296UH090XV60C 8267335 14ACX-060-230 TXV 58,500 14.50 12.00 C35-60C EL296UH110XE60C 8267342 14ACX-060-230 TXV 58,000 14.50 12.20 C35-60C EL296UH110XV60C 8267336 14ACX-060-230 TXV 59,000 14.70 12.20 C35-60C SL280UH090V60C 8267337 14ACX-060-230 TXV 59,000 14.70 12.20 C35-60C SL280UH090XV60C 8267339 14ACX-060-230 TXV 58,500 14.50 12.20 C35-60C SL280UH110V60C 8267338 14ACX-060-230 TXV 58,500 14.50 12.20 C35-60C SL280UH110XV60C 8267340 14ACX-060-230 TXV 58,500 14.50 12.00 C35-60C SLO185B124/141V60 8267329 14ACX-060-230 TXV 58,000 14.50 12.00 C35-60C SLP98UH090XV60C 8267333 14ACX-060-230 TXV 58,000 14.50 12.20 C35-60C SLP98UH110XV60C 8267334 14ACX-060-230 TXV 59,000 14.20 12.00 C35-60C 8267328 14ACX-060-230 TXV 58,500 14.50 12.20 C35-60D EL180UH135E60D 8267344 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 47 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-060-230 TXV 58,500 14.20 11.70 C35-60D EL195UH135XE60D 8267347 14ACX-060-230 TXV 58,500 14.20 11.70 C35-60D EL296UH135XE60D 8267348 14ACX-060-230 TXV 57,500 14.50 12.00 C35-60D EL296UH135XV60D 8267349 14ACX-060-230 TXV 58,000 15.00 12.20 C35-60D SL280UH135V60D 8267345 14ACX-060-230 TXV 57,500 14.50 12.00 C35-60D SLP98UH135XV60D 8267346 14ACX-060-230 TXV 58,500 14.00 11.70 C35-60D 8267343 14ACX-060-230 TXV 58,000 14.50 12.00 CBA27UHE-060 10259386 14ACX-060-230 TXV 58,000 14.00 11.70 CBX25UH-060 5732793 14ACX-060-230 TXV 58,500 14.50 12.20 CBX25UHV-060 6970135 14ACX-060-230 TXV 58,000 14.50 12.00 CBX27UH-060 5697724 14ACX-060-230 TXV 57,500 14.20 11.70 CBX32M-060 5697726 14ACX-060-230 TXV 57,000 14.20 11.70 CBX32MV-048 5697727 14ACX-060-230 TXV 57,500 14.20 12.00 CBX32MV-060 5697728 14ACX-060-230 TXV 57,500 14.50 12.00 CBX32MV-068 5697729 14ACX-060-230 TXV 57,500 14.20 12.00 CBX40UHV-060 9105790 14ACX-060-230 TXV 58,500 14.70 12.20 CH23-65 EL180UH090E60C 5736963 14ACX-060-230 TXV 58,500 14.50 12.20 CH23-65 EL180UH110E60C 5738743 14ACX-060-230 TXV 59,000 14.70 12.20 CH23-68 EL180UH135E60D 5745980 14ACX-060-230 TXV 59,000 14.20 12.00 CH23-68 EL195UH135XE60D 5697733 14ACX-060-230 TXV 57,500 14.50 12.00 CH23-68 EL296UH090XV60C 5697735 14ACX-060-230 TXV 58,500 14.50 12.00 CH23-68 EL296UH110XV60C 5697736 14ACX-060-230 TXV 59,000 14.20 12.00 CH23-68 EL296UH135XE60D 5697734 14ACX-060-230 TXV 59,000 14.50 12.20 CH23-68 EL296UH135XV60D 5697737 14ACX-060-230 TXV 58,000 14.50 12.20 CH23-68 SL280UH110V60C 5697739 14ACX-060-230 TXV 58,500 15.00 12.50 CH23-68 SL280UH135V60D 5697740 14ACX-060-230 TXV 58,500 14.20 11.70 CH23-68 5697732 14ACX-060-230 TXV 58,000 14.50 12.00 CH33-49 EL180UH090E60C 5736965 14ACX-060-230 TXV 58,000 14.20 12.00 CH33-49 EL180UH110E60C 5738744 14ACX-060-230 TXV 58,000 14.20 12.00 CH33-49 EL195UH110XE60C 5697742 14ACX-060-230 TXV 57,500 14.20 11.70 CH33-49 EL296UH090XV60C 5697744 14ACX-060-230 TXV 58,000 14.20 12.00 CH33-49 EL296UH110XE60C 5697743 14ACX-060-230 TXV 58,000 14.20 11.70 CH33-49 EL296UH110XV60C 5697745 14ACX-060-230 TXV 58,000 14.50 12.00 CH33-49 SL280UH090V60C 5697748 14ACX-060-230 TXV 58,000 14.20 12.00 CH33-49 SL280UH110V60C 5697749 14ACX-060-230 TXV 57,500 14.20 11.70 CH33-49 SLP98UH090XV60C 5697750 14ACX-060-230 TXV 57,500 14.20 12.00 CH33-49 SLP98UH110XV60C 5697751 14ACX-060-230 TXV 58,000 14.00 11.70 CH33-49 5697741 14ACX-060-230 TXV 57,500 14.20 11.70 CH33-50/60C SL280UH090V60C 5697835 14ACX-060-230 TXV 57,500 14.00 11.70 CH33-50/60C SL280UH110V60C 5697836 14ACX-060-230 TXV 58,000 14.00 11.70 CH33-50/60C 5697752 14ACX-060-230 TXV 57,500 14.20 12.00 CH33-60D EL180UH135E60D 5745981 14ACX-060-230 TXV 57,500 14.00 11.70 CH33-60D EL195UH135XE60D 5697758 14ACX-060-230 TXV 57,500 14.00 11.70 CH33-60D EL296UH135XE60D 5697759 14ACX-060-230 TXV 57,500 14.20 11.70 CH33-60D EL296UH135XV60D 5697760 14ACX-060-230 TXV 57,000 14.70 12.20 CH33-60D SL280UH135V60D 5697762 14ACX-060-230 TXV 57,500 14.20 12.00 CH33-60D SLP98UH135XV60D 5697763 14ACX-060-230 TXV 58,000 14.50 12.00 CH33-62D EL180UH135E60D 5745982 14ACX-060-230 TXV 58,000 14.20 11.70 CH33-62D EL195UH135XE60D 5697765 14ACX-060-230 TXV 58,000 14.20 11.70 CH33-62D EL296UH135XE60D 5697766 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 48 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-060-230 TXV 58,000 14.20 12.00 CH33-62D EL296UH135XV60D 5699647 14ACX-060-230 TXV 57,500 14.70 12.20 CH33-62D SL280UH135V60D 5697837 14ACX-060-230 TXV 57,500 14.50 12.00 CH33-62D SLP98UH135XV60D 5697768 14ACX-060-230 TXV 57,500 14.00 11.70 CH33-62D 5697764 14ACX-060-230 TXV 59,000 14.00 11.70 CH35-51C EL180UH110E60C 7163532 14ACX-060-230 TXV 57,500 14.25 11.70 CH35-51C EL296UH090XV60C 7163528 14ACX-060-230 TXV 58,000 14.25 11.70 CH35-51C EL296UH110XV60C 7163529 14ACX-060-230 TXV 58,000 14.25 12.00 CH35-51C SL280UH090V60C 7163550 14ACX-060-230 TXV 58,000 14.25 11.70 CH35-51C SL280UH110V60C 7163551 14ACX-060-230 TXV 57,500 14.25 11.70 CH35-51C SLP98UH090XV60C 7163533 14ACX-060-230 TXV 57,500 14.50 12.00 CH35-51C SLP98UH110XV60C 7163534 14ACX-060-230 TXV 58,500 14.00 11.70 CH35-51C 7163526 14ACX-060-230 TXV 58,500 14.50 12.00 CH35-60D EL180UH135E60D 7163539 14ACX-060-230 TXV 58,000 14.25 11.70 CH35-60D EL195UH135XE60D 7163536 14ACX-060-230 TXV 58,000 14.25 11.70 CH35-60D EL296UH135XE60D 7163538 14ACX-060-230 TXV 58,500 14.25 12.00 CH35-60D EL296UH135XV60D 7163537 14ACX-060-230 TXV 57,500 14.50 12.00 CH35-60D SL280UH135V60D 7163552 14ACX-060-230 TXV 58,000 14.50 12.00 CH35-60D SLP98UH135XV60D 7163540 14ACX-060-230 TXV 58,000 14.00 11.70 CH35-60D 7163535 14ACX-060-230 TXV 57,000 14.20 12.00 CR33-50/60 EL180DF110E60C 5733579 14ACX-060-230 TXV 57,000 14.20 12.00 CR33-50/60 EL195DF110XE60C 5697770 14ACX-060-230 TXV 57,000 14.20 12.00 CR33-50/60 EL296DF110XE60C 5697771 14ACX-060-230 TXV 56,500 14.00 11.70 CR33-50/60 SL280DF090V60C 5697775 14ACX-060-230 TXV 56,500 14.20 11.70 CR33-50/60 SL280DF110V60C 5697776 14ACX-060-230 TXV 58,000 14.50 12.00 CX34-49 EL180UH090E60C 5736968 14ACX-060-230 TXV 57,500 14.20 12.00 CX34-49 EL180UH110E60C 5738748 14ACX-060-230 TXV 57,500 14.20 12.00 CX34-49 EL180UH110XE60C 5739580 14ACX-060-230 TXV 57,500 14.20 12.00 CX34-49 EL195UH110XE60C 5697781 14ACX-060-230 TXV 57,000 14.20 11.70 CX34-49 EL296UH090XV60C 5697783 14ACX-060-230 TXV 57,500 14.20 12.00 CX34-49 EL296UH110XE60C 5697782 14ACX-060-230 TXV 57,000 14.20 12.00 CX34-49 EL296UH110XV60C 5697784 14ACX-060-230 TXV 58,000 14.20 12.00 CX34-49 SL280UH090V60C 5697788 14ACX-060-230 TXV 58,000 14.20 12.00 CX34-49 SL280UH090XV60C 5697790 14ACX-060-230 TXV 57,500 14.20 12.00 CX34-49 SL280UH110V60C 5697789 14ACX-060-230 TXV 57,500 14.20 12.00 CX34-49 SL280UH110XV60C 5697791 14ACX-060-230 TXV 57,000 14.20 11.70 CX34-49 SLP98UH090XV60C 5697792 14ACX-060-230 TXV 57,000 14.20 12.00 CX34-49 SLP98UH110XV60C 5697793 14ACX-060-230 TXV 58,000 14.00 11.70 CX34-49 5697780 14ACX-060-230 TXV 56,500 14.20 11.70 CX34-50/60C EL180UH090E60C 5736971 14ACX-060-230 TXV 56,500 14.00 11.70 CX34-50/60C EL180UH110E60C 5738751 14ACX-060-230 TXV 56,500 14.00 11.70 CX34-50/60C EL180UH110XE60C 5739583 14ACX-060-230 TXV 56,500 14.00 11.70 CX34-50/60C EL195UH110XE60C 5697795 14ACX-060-230 TXV 56,500 14.00 11.70 CX34-50/60C EL296UH110XE60C 5697796 14ACX-060-230 TXV 56,500 14.00 11.70 CX34-50/60C SL280UH090V60C 5697801 14ACX-060-230 TXV 56,500 14.00 11.70 CX34-50/60C SL280UH090XV60C 5697803 14ACX-060-230 TXV 58,000 14.50 12.00 CX34-60D EL180UH135E60D 5745983 14ACX-060-230 TXV 58,000 14.00 11.70 CX34-60D EL195UH135XE60D 5697808 14ACX-060-230 TXV 58,000 14.00 11.70 CX34-60D EL296UH135XE60D 5697809 14ACX-060-230 TXV 57,500 14.50 12.00 CX34-60D EL296UH135XV60D 5697810 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 49 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-060-230 TXV 57,500 14.70 12.20 CX34-60D SL280UH135V60D 5697812 14ACX-060-230 TXV 57,500 14.50 12.00 CX34-60D SLP98UH135XV60D 5697813 14ACX-060-230 TXV 57,500 14.00 11.70 CX34-60D 5697807 14ACX-060-230 TXV 59,000 14.70 12.20 CX34-62C EL180UH090E60C 5736972 14ACX-060-230 TXV 58,500 14.70 12.20 CX34-62C EL180UH110E60C 5738752 14ACX-060-230 TXV 58,500 14.70 12.20 CX34-62C EL180UH110XE60C 5739585 14ACX-060-230 TXV 58,500 14.50 12.00 CX34-62C EL195UH110XE60C 5697815 14ACX-060-230 TXV 58,000 14.50 12.00 CX34-62C EL296UH090XV60C 5697817 14ACX-060-230 TXV 58,500 14.50 12.00 CX34-62C EL296UH110XE60C 5697816 14ACX-060-230 TXV 58,000 14.50 12.20 CX34-62C EL296UH110XV60C 5697818 14ACX-060-230 TXV 59,000 14.70 12.20 CX34-62C SL280UH090V60C 5697822 14ACX-060-230 TXV 59,000 14.70 12.20 CX34-62C SL280UH090XV60C 5697824 14ACX-060-230 TXV 58,500 14.50 12.20 CX34-62C SL280UH110V60C 5697823 14ACX-060-230 TXV 58,500 14.50 12.20 CX34-62C SL280UH110XV60C 5697825 14ACX-060-230 TXV 58,500 14.50 12.00 CX34-62C SLO185B124/141V60 7110044 14ACX-060-230 TXV 58,000 14.50 12.00 CX34-62C SLP98UH090XV60C 5697826 14ACX-060-230 TXV 58,000 14.50 12.20 CX34-62C SLP98UH110XV60C 5697827 14ACX-060-230 TXV 59,000 14.20 12.00 CX34-62C 5697814 14ACX-060-230 TXV 58,500 14.50 12.20 CX34-62D EL180UH135E60D 5745984 14ACX-060-230 TXV 58,500 14.20 11.70 CX34-62D EL195UH135XE60D 5697829 14ACX-060-230 TXV 58,500 14.20 11.70 CX34-62D EL296UH135XE60D 5697830 14ACX-060-230 TXV 57,500 14.50 12.00 CX34-62D EL296UH135XV60D 5697831 14ACX-060-230 TXV 58,000 15.00 12.20 CX34-62D SL280UH135V60D 5697833 14ACX-060-230 TXV 57,500 14.50 12.00 CX34-62D SLP98UH135XV60D 5697834 14ACX-060-230 TXV 58,500 14.00 11.70 CX34-62D 5697828 14ACX-060-230 TXV 58,000 14.50 12.00 CX35-49C EL180UH090E60C 8267353 14ACX-060-230 TXV 57,500 14.20 12.00 CX35-49C EL180UH110E60C 8267352 14ACX-060-230 TXV 57,500 14.20 12.00 CX35-49C EL180UH110XE60C 8267351 14ACX-060-230 TXV 57,500 14.20 12.00 CX35-49C EL195UH110XE60C 8267359 14ACX-060-230 TXV 57,000 14.20 11.70 CX35-49C EL296UH090XV60C 8267361 14ACX-060-230 TXV 57,500 14.20 12.00 CX35-49C EL296UH110XE60C 8267360 14ACX-060-230 TXV 57,000 14.20 12.00 CX35-49C EL296UH110XV60C 8267362 14ACX-060-230 TXV 58,000 14.20 12.00 CX35-49C SL280UH090V60C 8267363 14ACX-060-230 TXV 58,000 14.20 12.00 CX35-49C SL280UH090XV60C 8267355 14ACX-060-230 TXV 57,500 14.20 12.00 CX35-49C SL280UH110V60C 8267354 14ACX-060-230 TXV 57,500 14.20 12.00 CX35-49C SL280UH110XV60C 8267356 14ACX-060-230 TXV 57,000 14.20 11.70 CX35-49C SLP98UH090XV60C 8267357 14ACX-060-230 TXV 57,000 14.20 12.00 CX35-49C SLP98UH110XV60C 8267358 14ACX-060-230 TXV 58,000 14.00 11.70 CX35-49C 8267350 14ACX-060-230 TXV 56,500 14.20 11.70 CX35-50/60C EL180UH090E60C 8267366 14ACX-060-230 TXV 56,500 14.00 11.70 CX35-50/60C EL180UH110E60C 8267364 14ACX-060-230 TXV 56,500 14.00 11.70 CX35-50/60C EL180UH110XE60C 8267365 14ACX-060-230 TXV 56,500 14.00 11.70 CX35-50/60C EL195UH110XE60C 8267370 14ACX-060-230 TXV 56,500 14.00 11.70 CX35-50/60C EL296UH110XE60C 8267367 14ACX-060-230 TXV 56,500 14.00 11.70 CX35-50/60C SL280UH090V60C 8267368 14ACX-060-230 TXV 56,500 14.00 11.70 CX35-50/60C SL280UH090XV60C 8267369 14ACX-060-230 TXV 59,000 14.70 12.20 CX35-60C EL180UH090E60C 8267375 14ACX-060-230 TXV 58,500 14.70 12.20 CX35-60C EL180UH110E60C 8267374 14ACX-060-230 TXV 58,500 14.70 12.20 CX35-60C EL180UH110XE60C 8267373 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 50 AHRI SYSTEM MATCHES - ALL REGIONS - 041-047-048-059-060 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-060-230 TXV 58,500 14.50 12.00 CX35-60C EL195UH110XE60C 8267382 14ACX-060-230 TXV 58,000 14.50 12.00 CX35-60C EL296UH090XV60C 8267384 14ACX-060-230 TXV 58,500 14.50 12.00 CX35-60C EL296UH110XE60C 8267383 14ACX-060-230 TXV 58,000 14.50 12.20 CX35-60C EL296UH110XV60C 8267385 14ACX-060-230 TXV 59,000 14.70 12.20 CX35-60C SL280UH090V60C 8267376 14ACX-060-230 TXV 59,000 14.70 12.20 CX35-60C SL280UH090XV60C 8267378 14ACX-060-230 TXV 58,500 14.50 12.20 CX35-60C SL280UH110V60C 8267377 14ACX-060-230 TXV 58,500 14.50 12.20 CX35-60C SL280UH110XV60C 8267379 14ACX-060-230 TXV 58,500 14.50 12.00 CX35-60C SLO185B124/141V60 8267372 14ACX-060-230 TXV 58,000 14.50 12.00 CX35-60C SLP98UH090XV60C 8267380 14ACX-060-230 TXV 58,000 14.50 12.20 CX35-60C SLP98UH110XV60C 8267381 14ACX-060-230 TXV 59,000 14.20 12.00 CX35-60C 8267371 14ACX-060-230 TXV 58,500 14.50 12.20 CX35-60D EL180UH135E60D 8267387 14ACX-060-230 TXV 58,500 14.20 11.70 CX35-60D EL195UH135XE60D 8267388 14ACX-060-230 TXV 58,500 14.20 11.70 CX35-60D EL296UH135XE60D 8267389 14ACX-060-230 TXV 57,500 14.50 12.00 CX35-60D EL296UH135XV60D 8267390 14ACX-060-230 TXV 58,000 15.00 12.20 CX35-60D SL280UH135V60D 8267391 14ACX-060-230 TXV 57,500 14.50 12.00 CX35-60D SLP98UH135XV60D 8267392 14ACX-060-230 TXV 58,500 14.00 11.70 CX35-60D 8267386 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 51 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS018-230A RFC 18,800 14.00 12.00 C33-25A 7625213 14ACXS018-230A RFC 18,800 14.00 12.00 C33-25B 7625220 14ACXS018-230A RFC 19,000 14.00 12.20 C33-31A 7625244 14ACXS018-230A RFC 19,000 14.00 12.20 C33-31B 7625250 14ACXS018-230A RFC 18,000 14.00 12.20 C35-18/24A 8471022 14ACXS018-230A RFC 18,000 14.00 12.20 C35-18/24B 8471023 14ACXS018-230A RFC 18,000 14.00 12.00 C35-24A 8471024 14ACXS018-230A RFC 18,000 14.00 12.00 C35-24B 8471026 14ACXS018-230A RFC 18,900 14.00 12.00 CH33-25A 7625288 14ACXS018-230A RFC 19,200 14.25 12.20 CH33-31A 7625305 14ACXS018-230A RFC 19,100 14.25 12.20 CH33-31B 7625309 14ACXS018-230A RFC 19,000 14.00 12.20 CR33-30/36A 7625341 14ACXS018-230A RFC 19,000 14.00 12.20 CR33-30/36B 7625344 14ACXS018-230A TXV 18,200 14.50 12.50 C33-18 EL180UH045E36A 7625197 14ACXS018-230A TXV 18,200 14.50 12.50 C33-18 EL180UH045XE36A 7625195 14ACXS018-230A TXV 19,500 16.00 13.00 C33-19 EL180UH045E36A 7625202 14ACXS018-230A TXV 19,500 16.00 13.00 C33-19 EL180UH045XE36A 7625200 14ACXS018-230A TXV 18,900 14.00 12.00 C33-19 7625199 14ACXS018-230A TXV 18,400 15.00 12.50 C33-24A EL180UH045E36A 7625205 14ACXS018-230A TXV 18,400 15.00 12.50 C33-24A EL180UH045XE36A 7625204 14ACXS018-230A TXV 18,500 14.50 12.20 C33-24B EL180UH070E36B 7625209 14ACXS018-230A TXV 18,500 14.50 12.20 C33-24B EL180UH070XE36B 7625207 14ACXS018-230A TXV 18,000 14.50 12.50 C33-24B EL195UH030XE24B 8606316 14ACXS018-230A TXV 18,000 14.50 12.50 C33-24B EL195UH045XE24B 8606318 14ACXS018-230A TXV 18,600 14.50 12.50 C33-24B EL195UH045XE36B 7625210 14ACXS018-230A TXV 18,600 14.50 12.50 C33-24B EL296UH045XE36B 7625212 14ACXS018-230A TXV 19,700 16.00 13.00 C33-25A EL180UH045E36A 7625218 14ACXS018-230A TXV 19,700 16.00 13.00 C33-25A EL180UH045XE36A 7625217 14ACXS018-230A TXV 19,200 14.25 12.20 C33-25A 7625215 14ACXS018-230A TXV 20,200 16.00 13.50 C33-25B CBWMV-36B-070 8994437 14ACXS018-230A TXV 19,500 15.50 12.50 C33-25B EL180UH070E36B 7625225 14ACXS018-230A TXV 19,500 15.50 12.50 C33-25B EL180UH070XE36B 7625224 14ACXS018-230A TXV 18,000 15.50 12.50 C33-25B EL195UH030XE24B 8606319 14ACXS018-230A TXV 18,000 15.50 12.50 C33-25B EL195UH045XE24B 8606320 14ACXS018-230A TXV 20,000 16.00 13.00 C33-25B EL195UH045XE36B 7625227 14ACXS018-230A TXV 20,000 16.00 13.00 C33-25B EL296UH045XE36B 7625228 14ACXS018-230A TXV 20,200 16.00 13.00 C33-25B EL296UH045XV36B 7625229 14ACXS018-230A TXV 20,200 16.00 13.00 C33-25B EL296UH070XE36B 9113210 14ACXS018-230A TXV 20,200 16.00 13.00 C33-25B EL296UH070XV36B 7625231 14ACXS018-230A TXV 20,200 16.00 13.00 C33-25B SLP98UH070XV36B 7629932 14ACXS018-230A TXV 19,200 14.25 12.20 C33-25B 7625222 14ACXS018-230A TXV 19,100 15.50 12.50 C33-30A EL180UH045E36A 7625232 14ACXS018-230A TXV 19,100 15.50 12.50 C33-30A EL180UH045XE36A 7625234 14ACXS018-230A TXV 18,900 15.00 12.50 C33-30B EL180UH070E36B 7625235 14ACXS018-230A TXV 18,900 15.00 12.50 C33-30B EL180UH070XE36B 7625237 14ACXS018-230A TXV 18,000 15.10 12.50 C33-30B EL195UH030XE24B 8606321 14ACXS018-230A TXV 18,000 15.10 12.50 C33-30B EL195UH045XE24B 8606322 14ACXS018-230A TXV 18,900 15.10 12.50 C33-30B EL195UH045XE36B 7625239 14ACXS018-230A TXV 18,900 15.10 12.50 C33-30B EL296UH045XE36B 7625240 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 52 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS018-230A TXV 19,500 16.00 13.00 C33-30B EL296UH045XV36B 7625242 14ACXS018-230A TXV 19,900 16.00 13.00 C33-31A EL180UH045E36A 7625247 14ACXS018-230A TXV 19,900 16.00 13.00 C33-31A EL180UH045XE36A 7625249 14ACXS018-230A TXV 19,300 14.50 12.20 C33-31A 7625245 14ACXS018-230A TXV 20,200 16.00 13.50 C33-31B CBWMV-36B-070 8994438 14ACXS018-230A TXV 19,700 15.50 12.50 C33-31B EL180UH070E36B 7625254 14ACXS018-230A TXV 19,700 15.50 12.50 C33-31B EL180UH070XE36B 7625255 14ACXS018-230A TXV 18,000 16.00 13.00 C33-31B EL195UH030XE24B 8606323 14ACXS018-230A TXV 18,000 16.00 13.00 C33-31B EL195UH045XE24B 8606324 14ACXS018-230A TXV 19,800 16.00 13.00 C33-31B EL195UH045XE36B 7625257 14ACXS018-230A TXV 19,800 16.00 13.00 C33-31B EL296UH045XE36B 7625259 14ACXS018-230A TXV 20,400 16.00 13.50 C33-31B EL296UH045XV36B 7625260 14ACXS018-230A TXV 20,400 16.00 13.50 C33-31B EL296UH070XV36B 7625262 14ACXS018-230A TXV 20,400 16.00 13.50 C33-31B SLP98UH070XV36B 7783663 14ACXS018-230A TXV 19,300 14.50 12.20 C33-31B 7625252 14ACXS018-230A TXV 19,700 16.00 13.00 C35-24A EL180UH045E36A 8260923 14ACXS018-230A TXV 19,700 16.00 13.00 C35-24A EL180UH045XE36A 8260922 14ACXS018-230A TXV 18,800 14.00 12.00 C35-24A 8260919 14ACXS018-230A TXV 19,500 15.50 12.50 C35-24B EL180UH070E36B 8261761 14ACXS018-230A TXV 19,500 15.50 12.50 C35-24B EL180UH070XE36B 8261759 14ACXS018-230A TXV 18,000 14.50 12.20 C35-24B EL195UH030XE24B 8606325 14ACXS018-230A TXV 18,000 14.50 12.20 C35-24B EL195UH045XE24B 8606326 14ACXS018-230A TXV 20,000 16.00 13.00 C35-24B EL195UH045XE36B 8261762 14ACXS018-230A TXV 20,000 16.00 13.00 C35-24B EL296UH045XE36B 8261764 14ACXS018-230A TXV 20,200 16.00 13.00 C35-24B EL296UH045XV36B 8261766 14ACXS018-230A TXV 20,200 16.00 13.00 C35-24B EL296UH070XV36B 8261767 14ACXS018-230A TXV 20,200 16.00 13.00 C35-24B SLP98UH070XV36B 8261758 14ACXS018-230A TXV 18,800 14.00 12.00 C35-24B 8261755 14ACXS018-230A TXV 19,900 16.00 13.00 C35-30A EL180UH045E36A 8260929 14ACXS018-230A TXV 19,900 16.00 13.00 C35-30A EL180UH045XE36A 8260930 14ACXS018-230A TXV 19,000 14.00 12.20 C35-30A 8260926 14ACXS018-230A TXV 19,700 15.50 12.50 C35-30B EL180UH070E36B 8260941 14ACXS018-230A TXV 19,700 15.50 12.50 C35-30B EL180UH070XE36B 8260942 14ACXS018-230A TXV 18,000 14.50 12.20 C35-30B EL195UH030XE24B 8606327 14ACXS018-230A TXV 18,000 14.50 12.20 C35-30B EL195UH045XE24B 8606328 14ACXS018-230A TXV 19,800 16.00 13.00 C35-30B EL195UH045XE36B 8260944 14ACXS018-230A TXV 19,800 16.00 13.00 C35-30B EL296UH045XE36B 8260936 14ACXS018-230A TXV 20,400 16.00 13.50 C35-30B EL296UH045XV36B 8260937 14ACXS018-230A TXV 20,400 16.00 13.50 C35-30B EL296UH070XV36B 8260939 14ACXS018-230A TXV 20,400 16.00 13.50 C35-30B SLP98UH070XV36B 8260934 14ACXS018-230A TXV 19,000 14.00 12.20 C35-30B 8260932 14ACXS018-230A TXV 19,400 16.00 13.00 CBA27UHE-018 10259479 14ACXS018-230A TXV 19,400 16.00 13.00 CBA27UHE-024 10259387 14ACXS018-230A TXV 18,700 14.25 12.00 CBX25UH-018 7625264 14ACXS018-230A TXV 18,800 14.25 12.00 CBX25UH-024 7625266 14ACXS018-230A TXV 19,000 15.50 12.50 CBX25UHV-018 7625267 14ACXS018-230A TXV 19,200 16.00 13.00 CBX25UHV-024 7625269 14ACXS018-230A TXV 19,700 16.00 13.00 CBX27UH-018 7625271 14ACXS018-230A TXV 19,700 16.00 13.00 CBX27UH-024 7625273 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 53 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS018-230A TXV 19,100 14.50 12.20 CBX32M-018/024 7625274 14ACXS018-230A TXV 19,300 14.50 12.50 CBX32M-030 7625276 14ACXS018-230A TXV 19,600 16.00 13.00 CBX32MV-018/024 7625278 14ACXS018-230A TXV 19,700 16.00 13.00 CBX32MV-024/030 7625280 14ACXS018-230A TXV 19,900 16.00 13.00 CBX40UHV-024 7625281 14ACXS018-230A TXV 19,800 16.00 13.00 CBX40UHV-030 7625283 14ACXS018-230A TXV 17,900 14.25 11.50 CH33-18A EL180UH045E36A 7625287 14ACXS018-230A TXV 17,900 14.25 11.50 CH33-18A EL180UH045XE36A 7625285 14ACXS018-230A TXV 19,400 16.00 13.00 CH33-19 EL180UH045E36A 7625385 14ACXS018-230A TXV 19,400 16.00 13.00 CH33-19 EL180UH045XE36A 7625384 14ACXS018-230A TXV 18,800 14.00 11.50 CH33-19 7625383 14ACXS018-230A TXV 19,300 16.00 13.00 CH33-24/30 EL180UH045E36A 7625388 14ACXS018-230A TXV 19,300 16.00 13.00 CH33-24/30 EL180UH045XE36A 7625387 14ACXS018-230A TXV 18,700 14.00 11.50 CH33-24/30 7625386 14ACXS018-230A TXV 19,800 16.00 13.00 CH33-25A EL180UH045E36A 7625294 14ACXS018-230A TXV 19,800 16.00 13.00 CH33-25A EL180UH045XE36A 7625292 14ACXS018-230A TXV 19,200 14.50 12.20 CH33-25A 7625290 14ACXS018-230A TXV 19,400 15.50 12.50 CH33-25B EL180UH070E36B 7625299 14ACXS018-230A TXV 19,400 15.50 12.50 CH33-25B EL180UH070XE36B 7625298 14ACXS018-230A TXV 18,000 14.25 12.00 CH33-25B EL195UH030XE24B 8606329 14ACXS018-230A TXV 18,000 14.25 12.00 CH33-25B EL195UH045XE24B 8606330 14ACXS018-230A TXV 19,900 16.00 13.00 CH33-25B EL195UH045XE36B 7625301 14ACXS018-230A TXV 19,900 16.00 13.00 CH33-25B EL296UH045XE36B 7625303 14ACXS018-230A TXV 20,200 16.00 13.00 CH33-25B EL296UH045XV36B 7625304 14ACXS018-230A TXV 19,100 14.25 12.00 CH33-25B 7625296 14ACXS018-230A TXV 20,200 16.00 13.00 CH33-31A EL180UH045E36A 7625308 14ACXS018-230A TXV 20,200 16.00 13.00 CH33-31A EL180UH045XE36A 7625307 14ACXS018-230A TXV 19,500 14.50 12.20 CH33-31A 7625306 14ACXS018-230A TXV 19,900 16.00 13.00 CH33-31B EL180UH070E36B 7625312 14ACXS018-230A TXV 19,900 16.00 13.00 CH33-31B EL180UH070XE36B 7625311 14ACXS018-230A TXV 18,000 14.50 12.20 CH33-31B EL195UH030XE24B 8606331 14ACXS018-230A TXV 18,000 14.50 12.20 CH33-31B EL195UH045XE24B 8606332 14ACXS018-230A TXV 19,900 16.00 13.00 CH33-31B EL195UH045XE36B 7625313 14ACXS018-230A TXV 19,900 16.00 13.00 CH33-31B EL296UH045XE36B 7625314 14ACXS018-230A TXV 20,600 16.00 13.50 CH33-31B EL296UH045XV36B 7625315 14ACXS018-230A TXV 19,500 14.50 12.20 CH33-31B 7625310 14ACXS018-230A TXV 19,400 16.00 13.00 CH35-18A EL180UH045E36A 7625318 14ACXS018-230A TXV 19,400 16.00 13.00 CH35-18A EL180UH045XE36A 7625317 14ACXS018-230A TXV 18,800 14.00 11.50 CH35-18A 7625316 14ACXS018-230A TXV 19,900 16.00 13.00 CH35-24A EL180UH045E36A 7625320 14ACXS018-230A TXV 19,900 16.00 13.00 CH35-24A EL180UH045XE36A 7625321 14ACXS018-230A TXV 19,300 14.50 12.20 CH35-24A 7625319 14ACXS018-230A TXV 19,500 15.50 12.50 CH35-24B EL180UH070E36B 7625323 14ACXS018-230A TXV 19,500 15.50 12.50 CH35-24B EL180UH070XE36B 7625324 14ACXS018-230A TXV 18,000 14.25 12.00 CH35-24B EL195UH030XE24B 8606333 14ACXS018-230A TXV 18,000 14.25 12.00 CH35-24B EL195UH045XE24B 8606334 14ACXS018-230A TXV 19,600 15.50 12.50 CH35-24B EL195UH045XE36B 7625325 14ACXS018-230A TXV 19,600 15.50 12.50 CH35-24B EL296UH045XE36B 7625326 14ACXS018-230A TXV 20,200 16.00 13.00 CH35-24B EL296UH045XV36B 7625327 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 54 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS018-230A TXV 19,100 14.25 12.00 CH35-24B 7625322 14ACXS018-230A TXV 20,200 16.00 13.00 CH35-30A EL180UH045E36A 7625330 14ACXS018-230A TXV 20,200 16.00 13.00 CH35-30A EL180UH045XE36A 7625329 14ACXS018-230A TXV 19,500 14.50 12.20 CH35-30A 7625328 14ACXS018-230A TXV 19,900 16.00 13.00 CH35-30B EL180UH070E36B 7625332 14ACXS018-230A TXV 19,900 16.00 13.00 CH35-30B EL180UH070XE36B 7625333 14ACXS018-230A TXV 18,000 14.50 12.20 CH35-30B EL195UH030XE24B 8606335 14ACXS018-230A TXV 18,000 14.50 12.20 CH35-30B EL195UH045XE24B 8606336 14ACXS018-230A TXV 19,900 16.00 13.00 CH35-30B EL195UH045XE36B 7625334 14ACXS018-230A TXV 19,900 16.00 13.00 CH35-30B EL296UH045XE36B 7625335 14ACXS018-230A TXV 20,600 16.00 13.50 CH35-30B EL296UH045XV36B 7625336 14ACXS018-230A TXV 19,500 14.50 12.20 CH35-30B 7625331 14ACXS018-230A TXV 19,200 15.50 12.50 CR33-18 EL180DF045E36A 7625338 14ACXS018-230A TXV 18,700 14.00 11.50 CR33-18 7625337 14ACXS018-230A TXV 18,600 15.10 12.50 CR33-24A EL180DF045E36A 7625339 14ACXS018-230A TXV 18,600 14.50 12.50 CR33-24B EL180DF070E36B 7625340 14ACXS018-230A TXV 19,800 16.00 13.00 CR33-30/36A EL180DF045E36A 7625343 14ACXS018-230A TXV 19,400 14.50 12.20 CR33-30/36A 7625342 14ACXS018-230A TXV 19,800 15.50 12.50 CR33-30/36B EL180DF070E36B 7625346 14ACXS018-230A TXV 19,400 14.50 12.20 CR33-30/36B 7625345 14ACXS018-230A TXV 18,400 15.00 12.50 CX34-18/24A EL180UH045E36A 7625347 14ACXS018-230A TXV 18,400 15.00 12.50 CX34-18/24A EL180UH045XE36A 7625348 14ACXS018-230A TXV 18,500 14.50 12.20 CX34-18/24B EL180UH070E36B 7625349 14ACXS018-230A TXV 18,500 14.50 12.20 CX34-18/24B EL180UH070XE36B 7625350 14ACXS018-230A TXV 18,000 14.50 12.50 CX34-18/24B EL195UH030XE24B 8606337 14ACXS018-230A TXV 18,000 14.50 12.50 CX34-18/24B EL195UH045XE24B 8606338 14ACXS018-230A TXV 18,600 14.50 12.50 CX34-18/24B EL195UH045XE36B 7625351 14ACXS018-230A TXV 18,600 14.50 12.50 CX34-18/24B EL296UH045XE36B 7625352 14ACXS018-230A TXV 19,500 16.00 13.00 CX34-19 EL180UH045E36A 7625355 14ACXS018-230A TXV 19,500 16.00 13.00 CX34-19 EL180UH045XE36A 7625354 14ACXS018-230A TXV 18,900 14.00 12.00 CX34-19 7625353 14ACXS018-230A TXV 19,700 16.00 13.00 CX34-25A EL180UH045E36A 7625358 14ACXS018-230A TXV 19,700 16.00 13.00 CX34-25A EL180UH045XE36A 7625357 14ACXS018-230A TXV 19,200 14.25 12.20 CX34-25A 7625356 14ACXS018-230A TXV 20,200 16.00 13.50 CX34-25B CBWMV-36B-070 8994439 14ACXS018-230A TXV 19,500 15.50 12.50 CX34-25B EL180UH070E36B 7625361 14ACXS018-230A TXV 19,500 15.50 12.50 CX34-25B EL180UH070XE36B 7625360 14ACXS018-230A TXV 18,000 15.50 12.50 CX34-25B EL195UH030XE24B 8606339 14ACXS018-230A TXV 18,000 15.50 12.50 CX34-25B EL195UH045XE24B 8606340 14ACXS018-230A TXV 20,000 16.00 13.00 CX34-25B EL195UH045XE36B 7625362 14ACXS018-230A TXV 20,000 16.00 13.00 CX34-25B EL296UH045XE36B 7625363 14ACXS018-230A TXV 20,200 16.00 13.00 CX34-25B EL296UH045XV36B 7625364 14ACXS018-230A TXV 20,200 16.00 13.00 CX34-25B EL296UH070XE36B 9113211 14ACXS018-230A TXV 20,200 16.00 13.00 CX34-25B EL296UH070XV36B 7625365 14ACXS018-230A TXV 20,200 16.00 13.00 CX34-25B SLP98UH070XV36B 7629935 14ACXS018-230A TXV 19,200 14.25 12.20 CX34-25B 7625359 14ACXS018-230A TXV 19,100 15.50 12.50 CX34-30A EL180UH045E36A 7625366 14ACXS018-230A TXV 19,100 15.50 12.50 CX34-30A EL180UH045XE36A 7625367 14ACXS018-230A TXV 18,900 15.00 12.50 CX34-30B EL180UH070E36B 7625368 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 55 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS018-230A TXV 18,900 15.00 12.50 CX34-30B EL180UH070XE36B 7625369 14ACXS018-230A TXV 18,000 15.10 12.50 CX34-30B EL195UH030XE24B 8606341 14ACXS018-230A TXV 18,000 15.10 12.50 CX34-30B EL195UH045XE24B 8606342 14ACXS018-230A TXV 18,900 15.10 12.50 CX34-30B EL195UH045XE36B 7625370 14ACXS018-230A TXV 18,900 15.10 12.50 CX34-30B EL296UH045XE36B 7625371 14ACXS018-230A TXV 19,500 16.00 13.00 CX34-30B EL296UH045XV36B 7625372 14ACXS018-230A TXV 19,900 16.00 13.00 CX34-31A EL180UH045E36A 7625374 14ACXS018-230A TXV 19,900 16.00 13.00 CX34-31A EL180UH045XE36A 7625375 14ACXS018-230A TXV 19,300 14.50 12.20 CX34-31A 7625373 14ACXS018-230A TXV 20,200 16.00 13.50 CX34-31B CBWMV-36B-070 8994440 14ACXS018-230A TXV 19,700 15.50 12.50 CX34-31B EL180UH070E36B 7625377 14ACXS018-230A TXV 19,700 15.50 12.50 CX34-31B EL180UH070XE36B 7625378 14ACXS018-230A TXV 18,000 16.00 13.00 CX34-31B EL195UH030XE24B 8606343 14ACXS018-230A TXV 18,000 16.00 13.00 CX34-31B EL195UH045XE24B 8606344 14ACXS018-230A TXV 19,800 16.00 13.00 CX34-31B EL195UH045XE36B 7625379 14ACXS018-230A TXV 19,800 16.00 13.00 CX34-31B EL296UH045XE36B 7625380 14ACXS018-230A TXV 20,400 16.00 13.50 CX34-31B EL296UH045XV36B 7625381 14ACXS018-230A TXV 20,400 16.00 13.50 CX34-31B EL296UH070XV36B 7625382 14ACXS018-230A TXV 20,400 16.00 13.50 CX34-31B SLP98UH070XV36B 7783664 14ACXS018-230A TXV 19,300 14.50 12.20 CX34-31B 7625376 14ACXS018-230A TXV 18,400 15.00 12.50 CX35-18/24A EL180UH045E36A 8260946 14ACXS018-230A TXV 18,400 15.00 12.50 CX35-18/24A EL180UH045XE36A 8260947 14ACXS018-230A TXV 18,500 14.50 12.20 CX35-18/24B EL180UH070E36B 8260949 14ACXS018-230A TXV 18,500 14.50 12.20 CX35-18/24B EL180UH070XE36B 8260951 14ACXS018-230A TXV 18,600 14.50 12.50 CX35-18/24B EL195UH045XE36B 8260952 14ACXS018-230A TXV 18,600 14.50 12.50 CX35-18/24B EL296UH045XE36B 8260954 14ACXS018-230A TXV 19,700 16.00 13.00 CX35-24A EL180UH045E36A 8260959 14ACXS018-230A TXV 19,700 16.00 13.00 CX35-24A EL180UH045XE36A 8260958 14ACXS018-230A TXV 19,200 14.25 12.20 CX35-24A 8260956 14ACXS018-230A TXV 19,500 15.50 12.50 CX35-24B EL180UH070E36B 8260971 14ACXS018-230A TXV 19,500 15.50 12.50 CX35-24B EL180UH070XE36B 8260969 14ACXS018-230A TXV 18,000 14.50 12.20 CX35-24B EL195UH030XE24B 8606345 14ACXS018-230A TXV 18,000 14.50 12.20 CX35-24B EL195UH045XE24B 8606346 14ACXS018-230A TXV 20,000 16.00 13.00 CX35-24B EL195UH045XE36B 8260974 14ACXS018-230A TXV 20,000 16.00 13.00 CX35-24B EL296UH045XE36B 8260975 14ACXS018-230A TXV 20,200 16.00 13.00 CX35-24B EL296UH045XV36B 8260966 14ACXS018-230A TXV 20,200 16.00 13.00 CX35-24B EL296UH070XV36B 8260967 14ACXS018-230A TXV 20,200 16.00 13.00 CX35-24B SLP98UH070XV36B 8260964 14ACXS018-230A TXV 19,200 14.25 12.20 CX35-24B 8260961 14ACXS018-230A TXV 19,900 16.00 13.00 CX35-30A EL180UH045E36A 8260979 14ACXS018-230A TXV 19,900 16.00 13.00 CX35-30A EL180UH045XE36A 8260981 14ACXS018-230A TXV 19,300 14.50 12.20 CX35-30A 8260977 14ACXS018-230A TXV 19,700 15.50 12.50 CX35-30B EL180UH070E36B 8260995 14ACXS018-230A TXV 19,700 15.50 12.50 CX35-30B EL180UH070XE36B 8260986 14ACXS018-230A TXV 18,000 14.50 12.20 CX35-30B EL195UH030XE24B 8606347 14ACXS018-230A TXV 18,000 14.50 12.20 CX35-30B EL195UH045XE24B 8606348 14ACXS018-230A TXV 19,800 16.00 13.00 CX35-30B EL195UH045XE36B 8260988 14ACXS018-230A TXV 19,800 16.00 13.00 CX35-30B EL296UH045XE36B 8260990 14ACXS018-230A TXV 20,400 16.00 13.50 CX35-30B EL296UH045XV36B 8260992 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 56 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS018-230A TXV 20,400 16.00 13.50 CX35-30B EL296UH070XV36B 8260993 14ACXS018-230A TXV 20,400 16.00 13.50 CX35-30B SLP98UH070XV36B 8260985 14ACXS018-230A TXV 19,300 14.50 12.20 CX35-30B 8260983 14ACXS024-230A RFC 23,800 14.00 12.00 C33-25A 7625157 14ACXS024-230A RFC 23,800 14.00 12.00 C33-25B 7625158 14ACXS024-230A RFC 24,000 14.20 12.20 C33-31A 7625160 14ACXS024-230A RFC 24,000 14.20 12.20 C33-31B 7625162 14ACXS024-230A RFC 24,000 14.50 12.50 C33-38A 7625169 14ACXS024-230A RFC 24,000 14.50 12.50 C33-38B 7625171 14ACXS024-230A RFC 23,400 14.00 12.20 C35-24A 8471025 14ACXS024-230A RFC 23,400 14.00 12.00 C35-24B 8471027 14ACXS024-230A RFC 23,600 14.00 12.00 C35-30/36A 8471028 14ACXS024-230A RFC 23,600 14.00 12.00 C35-30/36B 8471029 14ACXS024-230A RFC 23,600 14.00 12.00 C35-30/36C 8471030 14ACXS024-230A RFC 23,600 14.00 12.20 C35-30A 8471031 14ACXS024-230A RFC 23,600 14.00 12.20 C35-30B 8471034 14ACXS024-230A RFC 24,000 14.00 12.20 C35-36A 8471037 14ACXS024-230A RFC 24,000 14.00 12.20 C35-36B 8471040 14ACXS024-230A RFC 24,000 14.00 12.20 CH33-25A 7625173 14ACXS024-230A RFC 23,800 14.00 12.20 CH33-25B 7625175 14ACXS024-230A RFC 24,000 14.50 12.20 CH33-31A 7625177 14ACXS024-230A RFC 24,000 14.50 12.20 CH33-31B 7625178 14ACXS024-230A RFC 23,600 14.00 12.00 CH33-36A 7624821 14ACXS024-230A RFC 23,800 14.00 12.20 CH33-36C 7624853 14ACXS024-230A RFC 24,000 14.20 12.20 CH33-42B 7625184 14ACXS024-230A RFC 24,000 14.50 12.20 CH33-43B 7625185 14ACXS024-230A RFC 23,800 14.00 12.20 CH35-36A 7625192 14ACXS024-230A RFC 23,800 14.00 12.00 CH35-36B 7625180 14ACXS024-230A RFC 24,000 14.00 12.20 CH35-36C 7625191 14ACXS024-230A RFC 24,000 14.00 12.20 CR33-30/36A 7625187 14ACXS024-230A RFC 24,000 14.00 12.20 CR33-30/36B 7625189 14ACXS024-230A RFC 24,000 14.00 12.20 CR33-30/36C 7625182 14ACXS024-230A TXV 22,200 14.50 12.20 C33-18 EL180UH045E36A 7624481 14ACXS024-230A TXV 22,200 14.50 12.20 C33-18 EL180UH045XE36A 7624483 14ACXS024-230A TXV 23,800 16.00 13.00 C33-19 EL180UH045E36A 7624491 14ACXS024-230A TXV 23,800 16.00 13.00 C33-19 EL180UH045XE36A 7624493 14ACXS024-230A TXV 24,000 16.00 13.00 C33-19 SL280UH070V36A 7624488 14ACXS024-230A TXV 24,000 16.00 13.00 C33-19 SL280UH070XV36A 7624490 14ACXS024-230A TXV 23,400 14.25 11.50 C33-19 7624487 14ACXS024-230A TXV 22,800 15.00 12.50 C33-24A EL180UH045E36A 7624498 14ACXS024-230A TXV 22,800 15.00 12.50 C33-24A EL180UH045XE36A 7624500 14ACXS024-230A TXV 23,200 15.10 12.50 C33-24A SL280UH070V36A 7624495 14ACXS024-230A TXV 23,200 15.10 12.50 C33-24A SL280UH070XV36A 7624496 14ACXS024-230A TXV 22,800 15.10 12.50 C33-24B EL180UH070E36B 7624509 14ACXS024-230A TXV 22,800 15.10 12.50 C33-24B EL180UH070XE36B 7624511 14ACXS024-230A TXV 22,800 14.50 12.20 C33-24B EL195UH030XE24B 8606520 14ACXS024-230A TXV 22,800 14.50 12.20 C33-24B EL195UH045XE24B 8606522 14ACXS024-230A TXV 22,600 15.00 12.50 C33-24B EL195UH045XE36B 7624513 14ACXS024-230A TXV 23,000 15.00 12.50 C33-24B EL195UH070XE36B 7624514 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 57 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS024-230A TXV 22,600 15.00 12.50 C33-24B EL296UH045XE36B 7624516 14ACXS024-230A TXV 23,000 15.10 12.50 C33-24B EL296UH045XV36B 7624506 14ACXS024-230A TXV 23,000 15.10 12.50 C33-24B EL296UH070XE36B 7624518 14ACXS024-230A TXV 23,000 15.50 12.50 C33-24B EL296UH070XV36B 7624508 14ACXS024-230A TXV 23,200 15.10 12.50 C33-24B SL280UH090V36B 7624501 14ACXS024-230A TXV 23,200 15.10 12.50 C33-24B SL280UH090V48B 7624503 14ACXS024-230A TXV 23,200 15.10 12.50 C33-24B SL280UH090XV48B 7624504 14ACXS024-230A TXV 23,000 15.50 12.50 C33-24B SLP98UH070XV36B 7624519 14ACXS024-230A TXV 23,000 15.50 12.50 C33-24C EL296UH090XV36C 7624521 14ACXS024-230A TXV 23,000 15.50 12.50 C33-24C SLP98UH090XV36C 7624522 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25A EL180UH045E36A 7624529 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25A EL180UH045XE36A 7624531 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25A SL280UH070V36A 7624526 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25A SL280UH070XV36A 7624527 14ACXS024-230A TXV 23,800 14.25 12.20 C33-25A 7624524 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25B EL180UH070E36B 7624544 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25B EL180UH070XE36B 7624546 14ACXS024-230A TXV 24,000 15.50 12.50 C33-25B EL195UH030XE24B 8606523 14ACXS024-230A TXV 24,000 15.50 12.50 C33-25B EL195UH045XE24B 8606524 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25B EL195UH045XE36B 7624547 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25B EL195UH070XE36B 7624549 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25B EL296UH045XE36B 7624550 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25B EL296UH045XV36B 7624539 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25B EL296UH070XE36B 7624552 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25B EL296UH070XV36B 7624541 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25B SL280UH090V36B 7624534 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25B SL280UH090V48B 7624536 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25B SL280UH090XV48B 7624537 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25B SLO185B79/105V42 9010204 14ACXS024-230A TXV 24,000 16.00 13.00 C33-25B SLP98UH070XV36B 7624542 14ACXS024-230A TXV 23,800 14.25 12.20 C33-25B 7624533 14ACXS024-230A TXV 23,600 15.50 12.50 C33-30A EL180UH045E36A 7624562 14ACXS024-230A TXV 23,600 15.50 12.50 C33-30A EL180UH045XE36A 7624564 14ACXS024-230A TXV 23,600 15.10 12.50 C33-30A SL280UH070V36A 7624559 14ACXS024-230A TXV 23,600 15.10 12.50 C33-30A SL280UH070XV36A 7624561 14ACXS024-230A TXV 23,000 14.00 11.50 C33-30A 7624554 14ACXS024-230A TXV 23,400 15.50 12.50 C33-30B EL180UH070E36B 7624570 14ACXS024-230A TXV 23,400 15.50 12.50 C33-30B EL180UH070XE36B 7624572 14ACXS024-230A TXV 23,400 15.10 12.50 C33-30B EL195UH030XE24B 8606526 14ACXS024-230A TXV 23,400 15.10 12.50 C33-30B EL195UH045XE24B 8606527 14ACXS024-230A TXV 23,000 15.10 12.50 C33-30B EL195UH045XE36B 7624574 14ACXS024-230A TXV 23,400 15.50 12.50 C33-30B EL195UH070XE36B 7624575 14ACXS024-230A TXV 23,000 15.10 12.50 C33-30B EL296UH045XE36B 7624577 14ACXS024-230A TXV 23,600 15.50 12.50 C33-30B EL296UH045XV36B 7624580 14ACXS024-230A TXV 23,400 15.50 12.50 C33-30B EL296UH070XE36B 7624579 14ACXS024-230A TXV 23,600 15.50 12.50 C33-30B EL296UH070XV36B 7624582 14ACXS024-230A TXV 23,600 15.10 13.00 C33-30B SL280UH090V36B 7624566 14ACXS024-230A TXV 23,600 15.10 12.50 C33-30B SL280UH090V48B 7624567 14ACXS024-230A TXV 23,600 15.10 12.50 C33-30B SL280UH090XV48B 7624569 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS024-230A TXV 23,600 15.50 12.50 C33-30B SLP98UH070XV36B 7624583 14ACXS024-230A TXV 23,000 14.00 11.50 C33-30B 7624556 14ACXS024-230A TXV 23,600 16.00 13.00 C33-30C EL296UH090XV36C 7624585 14ACXS024-230A TXV 23,600 16.00 13.00 C33-30C SLP98UH090XV36C 7624587 14ACXS024-230A TXV 23,000 14.00 11.50 C33-30C 7624557 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31A EL180UH045E36A 7624593 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31A EL180UH045XE36A 7624595 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31A SL280UH070V36A 7624590 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31A SL280UH070XV36A 7624592 14ACXS024-230A TXV 24,000 14.50 12.20 C33-31A 7624588 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31B EL180UH070E36B 7624603 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31B EL180UH070XE36B 7624605 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31B EL195UH030XE24B 8606529 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31B EL195UH045XE24B 8606531 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31B EL195UH045XE36B 7624607 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31B EL195UH070XE36B 7624608 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31B EL296UH045XE36B 7624610 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31B EL296UH045XV36B 7624613 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31B EL296UH070XE36B 7624611 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31B EL296UH070XV36B 7624615 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31B SL280UH090V36B 7624598 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31B SL280UH090V48B 7624600 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31B SL280UH090XV48B 7624602 14ACXS024-230A TXV 24,000 16.00 13.00 C33-31B SLP98UH070XV36B 7624616 14ACXS024-230A TXV 24,000 14.50 12.20 C33-31B 7624597 14ACXS024-230A TXV 24,000 16.00 13.00 C33-36A EL180UH045E36A 7624627 14ACXS024-230A TXV 24,000 16.00 13.00 C33-36A EL180UH045XE36A 7624628 14ACXS024-230A TXV 24,000 16.00 13.00 C33-36A SL280UH070V36A 7624623 14ACXS024-230A TXV 24,000 16.00 13.00 C33-36A SL280UH070XV36A 7624625 14ACXS024-230A TXV 23,600 14.25 11.50 C33-36A 7624618 14ACXS024-230A TXV 24,000 16.00 13.00 C33-36B EL180UH070E36B 7624635 14ACXS024-230A TXV 24,000 16.00 13.00 C33-36B EL180UH070XE36B 7624636 14ACXS024-230A TXV 24,000 15.50 12.50 C33-36B EL195UH030XE24B 8606532 14ACXS024-230A TXV 24,000 15.50 12.50 C33-36B EL195UH045XE24B 8606534 14ACXS024-230A TXV 23,400 15.50 12.50 C33-36B EL195UH045XE36B 7624638 14ACXS024-230A TXV 23,600 15.50 13.00 C33-36B EL195UH070XE36B 7624640 14ACXS024-230A TXV 23,400 15.50 12.50 C33-36B EL296UH045XE36B 7624641 14ACXS024-230A TXV 24,000 16.00 13.00 C33-36B EL296UH045XV36B 7624644 14ACXS024-230A TXV 23,600 15.50 13.00 C33-36B EL296UH070XE36B 7624643 14ACXS024-230A TXV 24,000 16.00 13.00 C33-36B EL296UH070XV36B 7624646 14ACXS024-230A TXV 24,000 16.00 13.00 C33-36B SL280UH090V36B 7624630 14ACXS024-230A TXV 24,000 16.00 13.00 C33-36B SL280UH090V48B 7624631 14ACXS024-230A TXV 24,000 16.00 13.00 C33-36B SL280UH090XV48B 7624633 14ACXS024-230A TXV 24,000 16.00 13.00 C33-36B SLP98UH070XV36B 7624648 14ACXS024-230A TXV 23,600 14.50 12.00 C33-36B 7624620 14ACXS024-230A TXV 24,000 16.00 13.00 C33-36C EL296UH090XV36C 7624649 14ACXS024-230A TXV 24,000 16.00 13.00 C33-36C SLP98UH090XV36C 7624651 14ACXS024-230A TXV 23,600 14.50 12.00 C33-36C 7624622 14ACXS024-230A TXV 24,000 16.00 13.00 C33-38A EL180UH045E36A 7624658 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS024-230A TXV 24,000 16.00 13.00 C33-38A EL180UH045XE36A 7624659 14ACXS024-230A TXV 24,000 16.00 13.50 C33-38A SL280UH070V36A 7624654 14ACXS024-230A TXV 24,000 16.00 13.50 C33-38A SL280UH070XV36A 7624656 14ACXS024-230A TXV 24,000 14.50 12.50 C33-38A 7624653 14ACXS024-230A TXV 24,000 16.00 13.50 C33-38B EL180UH070E36B 7624667 14ACXS024-230A TXV 24,000 16.00 13.50 C33-38B EL180UH070XE36B 7624669 14ACXS024-230A TXV 24,000 16.00 13.00 C33-38B EL195UH030XE24B 8606535 14ACXS024-230A TXV 24,000 16.00 13.00 C33-38B EL195UH045XE24B 8606537 14ACXS024-230A TXV 24,000 16.00 13.00 C33-38B EL195UH045XE36B 7624671 14ACXS024-230A TXV 24,000 16.00 13.00 C33-38B EL195UH070XE36B 7624672 14ACXS024-230A TXV 24,000 16.00 13.00 C33-38B EL296UH045XE36B 7624674 14ACXS024-230A TXV 24,000 16.00 13.00 C33-38B EL296UH045XV36B 7624677 14ACXS024-230A TXV 24,000 16.00 13.00 C33-38B EL296UH070XE36B 7624676 14ACXS024-230A TXV 24,000 16.00 13.00 C33-38B EL296UH070XV36B 7624679 14ACXS024-230A TXV 24,000 16.00 13.50 C33-38B SL280UH090V36B 7624663 14ACXS024-230A TXV 24,000 16.00 13.00 C33-38B SL280UH090V48B 7624664 14ACXS024-230A TXV 24,000 16.00 13.00 C33-38B SL280UH090XV48B 7624666 14ACXS024-230A TXV 24,000 16.00 13.00 C33-38B SLP98UH070XV36B 7624680 14ACXS024-230A TXV 24,000 14.50 12.50 C33-38B 7624661 14ACXS024-230A TXV 23,400 15.10 12.50 C35-18/24B EL195UH030XE24B 8606538 14ACXS024-230A TXV 23,400 15.10 12.50 C35-18/24B EL195UH045XE24B 8606540 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24A EL180UH045E36A 8260522 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24A EL180UH045XE36A 8260524 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24A SL280UH070V36A 8260519 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24A SL280UH070XV36A 8260520 14ACXS024-230A TXV 24,000 14.25 12.20 C35-24A 8260517 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24B EL180UH070E36B 8260541 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24B EL180UH070XE36B 8260542 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24B EL195UH030XE24B 8606541 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24B EL195UH045XE24B 8606542 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24B EL195UH045XE36B 8260528 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24B EL195UH070XE36B 8260529 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24B EL296UH045XE36B 8260531 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24B EL296UH045XV36B 8260536 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24B EL296UH070XE36B 8260532 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24B EL296UH070XV36B 8260537 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24B SL280UH090V36B 8260544 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24B SL280UH090V48B 8260546 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24B SL280UH090XV48B 8260534 14ACXS024-230A TXV 24,000 16.00 13.00 C35-24B SLP98UH070XV36B 8260539 14ACXS024-230A TXV 23,800 14.00 12.00 C35-24B 8260525 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30/36A EL180UH045E36A 8260586 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30/36A EL180UH045XE36A 8260588 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30/36A SL280UH070V36A 8260583 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30/36A SL280UH070XV36A 8260584 14ACXS024-230A TXV 23,600 14.00 12.00 C35-30/36A 8260580 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30/36B EL180UH070E36B 8260607 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30/36B EL180UH070XE36B 8260609 14ACXS024-230A TXV 24,000 15.50 12.50 C35-30/36B EL195UH030XE24B 8606544 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 60 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS024-230A TXV 24,000 15.50 12.50 C35-30/36B EL195UH045XE24B 8606545 14ACXS024-230A TXV 23,400 15.50 12.50 C35-30/36B EL195UH045XE36B 8260611 14ACXS024-230A TXV 23,600 16.00 13.00 C35-30/36B EL195UH070XE36B 8260592 14ACXS024-230A TXV 23,400 15.50 12.50 C35-30/36B EL296UH045XE36B 8260593 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30/36B EL296UH045XV36B 8260596 14ACXS024-230A TXV 23,600 16.00 13.00 C35-30/36B EL296UH070XE36B 8260595 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30/36B EL296UH070XV36B 8260598 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30/36B SL280UH090V36B 8260602 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30/36B SL280UH090V48B 8260603 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30/36B SL280UH090XV48B 8260605 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30/36B SLP98UH070XV36B 8260600 14ACXS024-230A TXV 23,600 14.00 12.00 C35-30/36B 8260589 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30/36C EL296UH090XV36C 8260615 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30/36C SLP98UH090XV36C 8260617 14ACXS024-230A TXV 23,600 14.00 12.00 C35-30/36C 8260613 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30A EL180UH045E36A 8260550 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30A EL180UH045XE36A 8260551 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30A SL280UH070V36A 8260553 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30A SL280UH070XV36A 8260555 14ACXS024-230A TXV 24,000 14.50 12.20 C35-30A 8260548 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30B EL180UH070E36B 8260578 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30B EL180UH070XE36B 8260562 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30B EL195UH030XE24B 8606547 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30B EL195UH045XE24B 8606548 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30B EL195UH045XE36B 8260564 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30B EL195UH070XE36B 8260565 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30B EL296UH045XE36B 8260567 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30B EL296UH045XV36B 8260571 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30B EL296UH070XE36B 8260569 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30B EL296UH070XV36B 8260559 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30B SL280UH090V36B 8260573 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30B SL280UH090V48B 8260575 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30B SL280UH090XV48B 8260576 14ACXS024-230A TXV 24,000 16.00 13.00 C35-30B SLP98UH070XV36B 8260560 14ACXS024-230A TXV 24,000 14.50 12.20 C35-30B 8260556 14ACXS024-230A TXV 24,000 16.00 13.00 C35-36A EL180UH045E36A 8260624 14ACXS024-230A TXV 24,000 16.00 13.00 C35-36A EL180UH045XE36A 8260626 14ACXS024-230A TXV 24,000 16.00 13.50 C35-36A SL280UH070V36A 8260620 14ACXS024-230A TXV 24,000 16.00 13.50 C35-36A SL280UH070XV36A 8260622 14ACXS024-230A TXV 24,000 14.50 12.50 C35-36A 8260618 14ACXS024-230A TXV 24,000 16.00 13.50 C35-36B EL180UH070E36B 8260645 14ACXS024-230A TXV 24,000 16.00 13.50 C35-36B EL180UH070XE36B 8260647 14ACXS024-230A TXV 24,000 16.00 13.00 C35-36B EL195UH030XE24B 8606550 14ACXS024-230A TXV 24,000 16.00 13.00 C35-36B EL195UH045XE24B 8606551 14ACXS024-230A TXV 24,000 16.00 13.00 C35-36B EL195UH045XE36B 8260649 14ACXS024-230A TXV 24,000 16.00 13.00 C35-36B EL195UH070XE36B 8260630 14ACXS024-230A TXV 24,000 16.00 13.00 C35-36B EL296UH045XE36B 8260632 14ACXS024-230A TXV 24,000 16.00 13.00 C35-36B EL296UH045XV36B 8260636 14ACXS024-230A TXV 24,000 16.00 13.00 C35-36B EL296UH070XE36B 8260634 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 61 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS024-230A TXV 24,000 16.00 13.00 C35-36B EL296UH070XV36B 8260637 14ACXS024-230A TXV 24,000 16.00 13.50 C35-36B SL280UH090V36B 8260641 14ACXS024-230A TXV 24,000 16.00 13.00 C35-36B SL280UH090V48B 8260642 14ACXS024-230A TXV 24,000 16.00 13.00 C35-36B SL280UH090XV48B 8260644 14ACXS024-230A TXV 24,000 16.00 13.00 C35-36B SLP98UH070XV36B 8260639 14ACXS024-230A TXV 24,000 14.50 12.50 C35-36B 8260628 14ACXS024-230A TXV 24,000 16.00 13.00 CBA27UHE-024 10259388 14ACXS024-230A TXV 24,000 16.00 13.00 CBA27UHE-030 10259389 14ACXS024-230A TXV 23,600 14.50 12.20 CBX25UH-024 7624682 14ACXS024-230A TXV 23,800 14.50 12.20 CBX25UH-030 7624684 14ACXS024-230A TXV 24,000 14.50 12.20 CBX25UH-036 7624685 14ACXS024-230A TXV 24,000 16.00 13.00 CBX25UHV-024 7624687 14ACXS024-230A TXV 24,000 16.00 13.00 CBX25UHV-030 7624689 14ACXS024-230A TXV 24,000 16.00 13.00 CBX25UHV-036 7624690 14ACXS024-230A TXV 24,000 16.00 13.00 CBX27UH-024 7624692 14ACXS024-230A TXV 24,000 16.00 13.00 CBX27UH-030 7624694 14ACXS024-230A TXV 23,800 14.50 12.20 CBX32M-018/024 7624695 14ACXS024-230A TXV 24,000 15.10 12.50 CBX32M-030 7624697 14ACXS024-230A TXV 24,000 15.50 12.50 CBX32MV-018/024 7624698 14ACXS024-230A TXV 24,000 16.00 13.00 CBX32MV-024/030 7624700 14ACXS024-230A TXV 24,000 16.00 13.00 CBX40UHV-024 10090928 14ACXS024-230A TXV 22,800 15.10 12.50 CH23-31 EL180UH045E36A 7624703 14ACXS024-230A TXV 22,800 15.10 12.50 CH23-31 EL180UH045XE36A 7624705 14ACXS024-230A TXV 23,200 15.50 12.50 CH23-31 EL180UH070E36B 7624707 14ACXS024-230A TXV 23,200 15.50 12.50 CH23-31 EL180UH070XE36B 7624708 14ACXS024-230A TXV 22,800 14.50 12.50 CH23-31 EL195UH030XE24B 8606553 14ACXS024-230A TXV 22,800 14.50 12.50 CH23-31 EL195UH045XE24B 8606554 14ACXS024-230A TXV 23,000 15.10 12.50 CH23-31 EL195UH045XE36B 7624710 14ACXS024-230A TXV 23,000 15.10 12.50 CH23-31 EL195UH070XE36B 7624711 14ACXS024-230A TXV 23,000 15.10 12.50 CH23-31 EL296UH045XE36B 7624713 14ACXS024-230A TXV 23,200 15.50 12.50 CH23-31 EL296UH045XV36B 7624716 14ACXS024-230A TXV 23,000 15.10 12.50 CH23-31 EL296UH070XE36B 7624715 14ACXS024-230A TXV 23,200 15.50 13.00 CH23-31 EL296UH070XV36B 7624718 14ACXS024-230A TXV 23,400 15.10 13.00 CH23-31 SL280UH070V36A 7786572 14ACXS024-230A TXV 23,200 16.00 13.00 CH23-31 SL280UH090V36B 7624702 14ACXS024-230A TXV 23,200 15.50 13.00 CH23-31 SLP98UH070XV36B 7624720 14ACXS024-230A TXV 24,000 16.00 13.00 CH23-41 EL180UH045E36A 7624728 14ACXS024-230A TXV 24,000 16.00 13.00 CH23-41 EL180UH045XE36A 7624730 14ACXS024-230A TXV 24,000 16.00 13.00 CH23-41 EL180UH070E36B 7624731 14ACXS024-230A TXV 24,000 16.00 13.00 CH23-41 EL180UH070XE36B 7624733 14ACXS024-230A TXV 24,000 15.50 12.50 CH23-41 EL195UH030XE24B 8606556 14ACXS024-230A TXV 24,000 15.50 12.50 CH23-41 EL195UH045XE24B 8606557 14ACXS024-230A TXV 24,000 16.00 13.00 CH23-41 EL195UH045XE36B 7624735 14ACXS024-230A TXV 24,000 16.00 13.00 CH23-41 EL195UH070XE36B 7624736 14ACXS024-230A TXV 24,000 16.00 13.00 CH23-41 EL296UH045XE36B 7624738 14ACXS024-230A TXV 24,000 16.00 13.00 CH23-41 EL296UH045XV36B 7624742 14ACXS024-230A TXV 24,000 16.00 13.00 CH23-41 EL296UH070XE36B 7624740 14ACXS024-230A TXV 24,000 16.00 13.00 CH23-41 EL296UH070XV36B 7624743 14ACXS024-230A TXV 24,000 16.00 13.00 CH23-41 SL280UH070V36A 7624725 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 62 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS024-230A TXV 24,000 16.00 13.00 CH23-41 SL280UH090V36B 7624726 14ACXS024-230A TXV 24,000 16.00 13.00 CH23-41 SLP98UH070XV36B 7624745 14ACXS024-230A TXV 23,800 14.50 12.00 CH23-41 7624723 14ACXS024-230A TXV 23,800 15.50 12.50 CH33-19 EL180UH045E36A 7624752 14ACXS024-230A TXV 23,800 15.50 12.50 CH33-19 EL180UH045XE36A 7624754 14ACXS024-230A TXV 24,000 15.10 13.00 CH33-19 SL280UH070V36A 7624749 14ACXS024-230A TXV 24,000 15.10 13.00 CH33-19 SL280UH070XV36A 7624750 14ACXS024-230A TXV 23,200 14.00 11.50 CH33-19 7624747 14ACXS024-230A TXV 23,800 15.50 12.50 CH33-24/30 EL180UH045E36A 7624761 14ACXS024-230A TXV 23,800 15.50 12.50 CH33-24/30 EL180UH045XE36A 7624763 14ACXS024-230A TXV 23,800 15.10 13.00 CH33-24/30 SL280UH070V36A 7624758 14ACXS024-230A TXV 23,800 15.10 13.00 CH33-24/30 SL280UH070XV36A 7624759 14ACXS024-230A TXV 23,200 14.00 11.50 CH33-24/30 7624756 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-25A EL180UH045E36A 7624770 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-25A EL180UH045XE36A 7624772 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-25A SL280UH070V36A 7624766 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-25A SL280UH070XV36A 7624768 14ACXS024-230A TXV 24,000 14.50 12.20 CH33-25A 7624765 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-25B EL180UH070E36B 7624777 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-25B EL180UH070XE36B 7624779 14ACXS024-230A TXV 24,000 15.50 12.50 CH33-25B EL195UH030XE24B 8606558 14ACXS024-230A TXV 24,000 15.50 12.50 CH33-25B EL195UH045XE24B 8606560 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-25B EL195UH045XE36B 7624780 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-25B EL195UH070XE36B 7624782 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-25B EL296UH045XE36B 7624784 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-25B EL296UH045XV36B 7624787 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-25B EL296UH070XE36B 7624786 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-25B EL296UH070XV36B 7624789 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-25B SL280UH090V36B 7624775 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-25B SLP98UH070XV36B 7624791 14ACXS024-230A TXV 23,800 14.50 12.00 CH33-25B 7624773 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-31A EL180UH045E36A 7624798 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-31A EL180UH045XE36A 7624800 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-31A SL280UH070V36A 7624795 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-31A SL280UH070XV36A 7624796 14ACXS024-230A TXV 24,000 14.50 12.50 CH33-31A 7624793 14ACXS024-230A TXV 24,000 16.00 13.50 CH33-31B EL180UH070E36B 7624805 14ACXS024-230A TXV 24,000 16.00 13.50 CH33-31B EL180UH070XE36B 7624807 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-31B EL195UH030XE24B 8606561 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-31B EL195UH045XE24B 8606563 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-31B EL195UH045XE36B 7624809 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-31B EL195UH070XE36B 7624810 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-31B EL296UH045XE36B 7624812 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-31B EL296UH045XV36B 7624816 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-31B EL296UH070XE36B 7624814 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-31B EL296UH070XV36B 7624817 14ACXS024-230A TXV 24,000 16.00 13.50 CH33-31B SL280UH090V36B 7624803 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-31B SLP98UH070XV36B 7624819 14ACXS024-230A TXV 24,000 14.50 12.50 CH33-31B 7624802 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 63 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36A EL180UH045E36A 7624828 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36A EL180UH045XE36A 7624830 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36A SL280UH070V36A 7624825 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36A SL280UH070XV36A 7624826 14ACXS024-230A TXV 23,800 14.25 12.00 CH33-36A 7624823 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36B EL180UH070E36B 7624837 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36B EL180UH070XE36B 7624839 14ACXS024-230A TXV 24,000 15.50 12.50 CH33-36B EL195UH030XE24B 8606564 14ACXS024-230A TXV 24,000 15.50 12.50 CH33-36B EL195UH045XE24B 8606565 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36B EL195UH045XE36B 7624840 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36B EL195UH070XE36B 7624842 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36B EL296UH045XE36B 7624844 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36B EL296UH045XV36B 7624847 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36B EL296UH070XE36B 7624846 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36B EL296UH070XV36B 7624849 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36B SL280UH090V36B 7624835 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36B SLP98UH070XV36B 7624851 14ACXS024-230A TXV 23,800 14.50 12.00 CH33-36B 7624833 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36C EL296UH090XV36C 7624856 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-36C SLP98UH090XV36C 7624858 14ACXS024-230A TXV 23,600 14.20 12.00 CH33-36C 7624855 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-42 EL195UH030XE24B 8606567 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-42 EL195UH045XE24B 8606568 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-43B EL195UH030XE24B 8606570 14ACXS024-230A TXV 24,000 16.00 13.00 CH33-43B EL195UH045XE24B 8606571 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-18A EL180UH045E36A 7624865 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-18A EL180UH045XE36A 7624867 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-18A SL280UH070V36A 7624862 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-18A SL280UH070XV36A 7624864 14ACXS024-230A TXV 23,400 14.25 11.50 CH35-18A 7624860 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-24A EL180UH045E36A 7624874 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-24A EL180UH045XE36A 7624876 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-24A SL280UH070V36A 7624871 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-24A SL280UH070XV36A 7624872 14ACXS024-230A TXV 23,800 14.50 12.20 CH35-24A 7624869 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-24B EL180UH070E36B 7624881 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-24B EL180UH070XE36B 7624883 14ACXS024-230A TXV 24,000 15.50 12.50 CH35-24B EL195UH030XE24B 8606572 14ACXS024-230A TXV 24,000 15.50 12.50 CH35-24B EL195UH045XE24B 8606574 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-24B EL195UH045XE36B 7624885 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-24B EL195UH070XE36B 7624887 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-24B EL296UH045XV36B 7624888 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-24B EL296UH070XV36B 7624890 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-24B SL280UH090V36B 7624880 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-24B SLP98UH070XV36B 7624892 14ACXS024-230A TXV 24,000 14.50 12.20 CH35-24B 7624878 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-30A EL180UH045E36A 7624899 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-30A EL180UH045XE36A 7624901 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-30A SL280UH070V36A 7624896 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 64 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-30A SL280UH070XV36A 7624897 14ACXS024-230A TXV 24,000 15.00 12.50 CH35-30A 7624894 14ACXS024-230A TXV 24,000 16.00 13.50 CH35-30B EL180UH070E36B 7624906 14ACXS024-230A TXV 24,000 16.00 13.50 CH35-30B EL180UH070XE36B 7624908 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-30B EL195UH030XE24B 8606575 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-30B EL195UH045XE24B 8606577 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-30B EL195UH045XE36B 7624910 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-30B EL195UH070XE36B 7624911 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-30B EL296UH045XV36B 7624913 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-30B EL296UH070XV36B 7624915 14ACXS024-230A TXV 24,000 16.00 13.50 CH35-30B SL280UH090V36B 7624904 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-30B SLP98UH070XV36B 7624917 14ACXS024-230A TXV 24,000 14.50 12.50 CH35-30B 7624903 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-36A EL180UH045E36A 7624924 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-36A EL180UH045XE36A 7624925 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-36A SL280UH070V36A 7624920 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-36A SL280UH070XV36A 7624922 14ACXS024-230A TXV 23,800 14.25 12.20 CH35-36A 7624918 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-36B EL180UH070E36B 7624931 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-36B EL180UH070XE36B 7624933 14ACXS024-230A TXV 24,000 15.50 12.50 CH35-36B EL195UH030XE24B 8606578 14ACXS024-230A TXV 24,000 15.50 12.50 CH35-36B EL195UH045XE24B 8606580 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-36B EL195UH045XE36B 7624934 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-36B EL195UH070XE36B 7624936 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-36B EL296UH045XV36B 7624938 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-36B EL296UH070XV36B 7624940 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-36B SL280UH090V36B 7624929 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-36B SLP98UH070XV36B 7624941 14ACXS024-230A TXV 23,800 14.00 12.20 CH35-36B 7624927 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-36C EL296UH090XV36C 7624945 14ACXS024-230A TXV 24,000 16.00 13.00 CH35-36C SLP98UH090XV36C 7624947 14ACXS024-230A TXV 24,000 14.25 12.20 CH35-36C 7624943 14ACXS024-230A TXV 23,400 15.10 12.50 CR33-24A EL180DF045E36A 7624950 14ACXS024-230A TXV 23,000 15.10 12.50 CR33-24A SL280DF070V36A 7624948 14ACXS024-230A TXV 23,000 15.10 12.50 CR33-24B EL180DF070E36B 7624952 14ACXS024-230A TXV 22,600 15.00 12.50 CR33-24B EL195DF045XE36B 7624954 14ACXS024-230A TXV 22,800 15.00 12.50 CR33-24B EL195DF070XE48B 7624955 14ACXS024-230A TXV 22,600 15.00 12.50 CR33-24B EL296DF045XE36B 7624957 14ACXS024-230A TXV 23,000 15.10 12.50 CR33-24B EL296DF045XV36B 7624961 14ACXS024-230A TXV 22,800 15.00 12.50 CR33-24B EL296DF070XE48B 7624959 14ACXS024-230A TXV 23,200 15.10 12.50 CR33-24B SLP98DF070XV36B 7624962 14ACXS024-230A TXV 24,000 16.00 13.00 CR33-30/36A EL180DF045E36A 7624968 14ACXS024-230A TXV 24,000 16.00 13.00 CR33-30/36A SL280DF070V36A 7624966 14ACXS024-230A TXV 24,000 14.50 12.20 CR33-30/36A 7624964 14ACXS024-230A TXV 24,000 16.00 13.00 CR33-30/36B EL180DF070E36B 7624971 14ACXS024-230A TXV 24,000 16.00 13.00 CR33-30/36B EL195DF045XE36B 7624973 14ACXS024-230A TXV 24,000 16.00 13.00 CR33-30/36B EL195DF070XE48B 7624974 14ACXS024-230A TXV 24,000 16.00 13.00 CR33-30/36B EL296DF045XE36B 7624976 14ACXS024-230A TXV 24,000 16.00 13.00 CR33-30/36B EL296DF045XV36B 7624981 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 65 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS024-230A TXV 24,000 16.00 13.00 CR33-30/36B EL296DF070XE48B 7624978 14ACXS024-230A TXV 24,000 16.00 13.00 CR33-30/36B EL296DF070XV48B 7624982 14ACXS024-230A TXV 24,000 16.00 13.00 CR33-30/36B SL280DF090V48B 7624979 14ACXS024-230A TXV 24,000 16.00 13.00 CR33-30/36B SLP98DF070XV36B 7624984 14ACXS024-230A TXV 24,000 14.50 12.20 CR33-30/36B 7624969 14ACXS024-230A TXV 24,000 16.00 13.00 CR33-30/36C SLP98DF090XV36C 7624988 14ACXS024-230A TXV 24,000 14.50 12.20 CR33-30/36C 7624986 14ACXS024-230A TXV 22,800 15.00 12.50 CX34-18/24A EL180UH045E36A 7624989 14ACXS024-230A TXV 22,800 15.00 12.50 CX34-18/24A EL180UH045XE36A 7624991 14ACXS024-230A TXV 22,800 14.50 12.20 CX34-18/24B EL195UH030XE24B 8606581 14ACXS024-230A TXV 22,800 14.50 12.20 CX34-18/24B EL195UH045XE24B 8606583 14ACXS024-230A TXV 23,800 16.00 13.00 CX34-19 EL180UH045E36A 7624997 14ACXS024-230A TXV 23,800 16.00 13.00 CX34-19 EL180UH045XE36A 7624999 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-19 SL280UH070V36A 7624994 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-19 SL280UH070XV36A 7624996 14ACXS024-230A TXV 23,400 14.25 11.50 CX34-19 7624993 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25A EL180UH045E36A 7625006 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25A EL180UH045XE36A 7625007 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25A SL280UH070V36A 7625002 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25A SL280UH070XV36A 7625004 14ACXS024-230A TXV 23,800 14.25 12.20 CX34-25A 7625001 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25B EL180UH070E36B 7625020 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25B EL180UH070XE36B 7625022 14ACXS024-230A TXV 24,000 15.50 12.50 CX34-25B EL195UH030XE24B 8606584 14ACXS024-230A TXV 24,000 15.50 12.50 CX34-25B EL195UH045XE24B 8606586 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25B EL195UH045XE36B 7625024 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25B EL195UH070XE36B 7625025 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25B EL296UH045XE36B 7625027 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25B EL296UH045XV36B 7625016 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25B EL296UH070XE36B 7625029 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25B EL296UH070XV36B 7625017 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25B SL280UH090V36B 7625011 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25B SL280UH090V48B 7625012 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25B SL280UH090XV48B 7625014 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25B SLO185B79/105V42 9010205 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-25B SLP98UH070XV36B 7625019 14ACXS024-230A TXV 23,800 14.25 12.20 CX34-25B 7625009 14ACXS024-230A TXV 23,600 15.50 12.50 CX34-30A EL180UH045E36A 7625037 14ACXS024-230A TXV 23,600 15.50 12.50 CX34-30A EL180UH045XE36A 7625039 14ACXS024-230A TXV 23,600 15.10 12.50 CX34-30A SL280UH070V36A 7625034 14ACXS024-230A TXV 23,600 15.10 12.50 CX34-30A SL280UH070XV36A 7625035 14ACXS024-230A TXV 23,000 14.00 11.50 CX34-30A 7625030 14ACXS024-230A TXV 23,400 15.50 12.50 CX34-30B EL180UH070E36B 7625045 14ACXS024-230A TXV 23,400 15.50 12.50 CX34-30B EL180UH070XE36B 7625047 14ACXS024-230A TXV 23,400 15.10 12.50 CX34-30B EL195UH030XE24B 8606587 14ACXS024-230A TXV 23,400 15.10 12.50 CX34-30B EL195UH045XE24B 8606589 14ACXS024-230A TXV 23,000 15.10 12.50 CX34-30B EL195UH045XE36B 7625048 14ACXS024-230A TXV 23,400 15.50 12.50 CX34-30B EL195UH070XE36B 7625050 14ACXS024-230A TXV 23,000 15.10 12.50 CX34-30B EL296UH045XE36B 7625052 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 66 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS024-230A TXV 23,600 15.50 12.50 CX34-30B EL296UH045XV36B 7625055 14ACXS024-230A TXV 23,400 15.50 12.50 CX34-30B EL296UH070XE36B 7625053 14ACXS024-230A TXV 23,600 15.50 12.50 CX34-30B EL296UH070XV36B 7625056 14ACXS024-230A TXV 23,600 15.10 13.00 CX34-30B SL280UH090V36B 7625040 14ACXS024-230A TXV 23,600 15.10 12.50 CX34-30B SL280UH090V48B 7625042 14ACXS024-230A TXV 23,600 15.10 12.50 CX34-30B SL280UH090XV48B 7625044 14ACXS024-230A TXV 23,600 15.50 12.50 CX34-30B SLP98UH070XV36B 7625058 14ACXS024-230A TXV 23,000 14.00 11.50 CX34-30B 7625032 14ACXS024-230A TXV 23,600 16.00 13.00 CX34-30C EL296UH090XV36C 7625060 14ACXS024-230A TXV 23,600 16.00 13.00 CX34-30C SLP98UH090XV36C 7625061 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31A EL180UH045E36A 7625068 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31A EL180UH045XE36A 7625070 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31A SL280UH070V36A 7625065 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31A SL280UH070XV36A 7625066 14ACXS024-230A TXV 24,000 14.50 12.20 CX34-31A 7625063 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31B EL180UH070E36B 7625077 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31B EL180UH070XE36B 7625079 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31B EL195UH030XE24B 8606590 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31B EL195UH045XE24B 8606591 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31B EL195UH045XE36B 7625081 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31B EL195UH070XE36B 7625082 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31B EL296UH045XE36B 7625084 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31B EL296UH045XV36B 7625087 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31B EL296UH070XE36B 7625086 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31B EL296UH070XV36B 7625089 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31B SL280UH090V36B 7625073 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31B SL280UH090V48B 7625074 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31B SL280UH090XV48B 7625076 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-31B SLP98UH070XV36B 7625091 14ACXS024-230A TXV 24,000 14.50 12.20 CX34-31B 7625071 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-36A EL180UH045E36A 7625102 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-36A EL180UH045XE36A 7625101 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-36A SL280UH070V36A 7625097 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-36A SL280UH070XV36A 7625099 14ACXS024-230A TXV 23,600 14.50 12.00 CX34-36A 7625092 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-36B EL180UH070E36B 7625109 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-36B EL180UH070XE36B 7625110 14ACXS024-230A TXV 24,000 15.50 12.50 CX34-36B EL195UH030XE24B 8606593 14ACXS024-230A TXV 24,000 15.50 12.50 CX34-36B EL195UH045XE24B 8606594 14ACXS024-230A TXV 23,400 15.50 12.50 CX34-36B EL195UH045XE36B 7625112 14ACXS024-230A TXV 23,600 15.50 13.00 CX34-36B EL195UH070XE36B 7625114 14ACXS024-230A TXV 23,400 15.50 12.50 CX34-36B EL296UH045XE36B 7625115 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-36B EL296UH045XV36B 7625119 14ACXS024-230A TXV 23,600 15.50 13.00 CX34-36B EL296UH070XE36B 7625117 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-36B EL296UH070XV36B 7625120 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-36B SL280UH090V36B 7625104 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-36B SL280UH090V48B 7625106 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-36B SL280UH090XV48B 7625107 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-36B SLP98UH070XV36B 7625122 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 67 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS024-230A TXV 23,600 14.00 11.50 CX34-36B 7625094 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-36C EL296UH090XV36C 7625124 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-36C SLP98UH090XV36C 7625125 14ACXS024-230A TXV 23,600 14.50 12.00 CX34-36C 7625096 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-38A EL180UH045E36A 7625132 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-38A EL180UH045XE36A 7625134 14ACXS024-230A TXV 24,000 16.00 13.50 CX34-38A SL280UH070V36A 7625129 14ACXS024-230A TXV 24,000 16.00 13.50 CX34-38A SL280UH070XV36A 7625130 14ACXS024-230A TXV 24,000 14.50 12.50 CX34-38A 7625127 14ACXS024-230A TXV 24,000 16.00 13.50 CX34-38B EL180UH070E36B 7625142 14ACXS024-230A TXV 24,000 16.00 13.50 CX34-38B EL180UH070XE36B 7625143 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-38B EL195UH030XE24B 8606596 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-38B EL195UH045XE24B 8606597 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-38B EL195UH045XE36B 7625145 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-38B EL195UH070XE36B 7625147 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-38B EL296UH045XE36B 7625148 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-38B EL296UH045XV36B 7625152 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-38B EL296UH070XE36B 7625150 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-38B EL296UH070XV36B 7625153 14ACXS024-230A TXV 24,000 16.00 13.50 CX34-38B SL280UH090V36B 7625137 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-38B SL280UH090V48B 7625139 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-38B SL280UH090XV48B 7625140 14ACXS024-230A TXV 24,000 16.00 13.00 CX34-38B SLP98UH070XV36B 7625155 14ACXS024-230A TXV 24,000 14.50 12.50 CX34-38B 7625135 14ACXS024-230A TXV 22,800 15.00 12.50 CX35-18/24A EL180UH045E36A 8260651 14ACXS024-230A TXV 22,800 15.00 12.50 CX35-18/24A EL180UH045XE36A 8260652 14ACXS024-230A TXV 23,400 15.10 12.50 CX35-18/24B EL195UH030XE24B 8606599 14ACXS024-230A TXV 23,400 15.00 12.50 CX35-18/24B EL195UH045XE24B 8606600 14ACXS024-230A TXV 23,600 15.50 12.50 CX35-24A EL180UH045E36A 8260659 14ACXS024-230A TXV 23,600 15.50 11.50 CX35-24A EL180UH045XE36A 8260661 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24A SL280UH070V36A 8260656 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24A SL280UH070XV36A 8260657 14ACXS024-230A TXV 24,000 14.25 12.20 CX35-24A 8260654 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24B EL180UH070E36B 8260664 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24B EL180UH070XE36B 8260666 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24B EL195UH030XE24B 8606602 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24B EL195UH045XE24B 8606603 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24B EL195UH045XE36B 8260668 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24B EL195UH070XE36B 8260669 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24B EL296UH045XE36B 8260671 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24B EL296UH045XV36B 8260679 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24B EL296UH070XE36B 8260673 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24B EL296UH070XV36B 8260681 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24B SL280UH090V36B 8260674 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24B SL280UH090V48B 8260676 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24B SL280UH090XV48B 8260678 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-24B SLP98UH070XV36B 8260683 14ACXS024-230A TXV 24,000 14.25 12.20 CX35-24B 8260662 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30/36A EL180UH045E36A 8260718 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 68 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30/36A EL180UH045XE36A 8260716 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30/36A SL280UH070V36A 8260719 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30/36A SL280UH070XV36A 8260721 14ACXS024-230A TXV 23,800 14.50 12.00 CX35-30/36A 8260714 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30/36B EL180UH070E36B 8260744 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30/36B EL180UH070XE36B 8260728 14ACXS024-230A TXV 24,000 15.50 12.50 CX35-30/36B EL195UH030XE24B 8606605 14ACXS024-230A TXV 24,000 15.50 12.50 CX35-30/36B EL195UH045XE24B 8606606 14ACXS024-230A TXV 23,400 15.50 12.50 CX35-30/36B EL195UH045XE36B 8260730 14ACXS024-230A TXV 23,600 16.00 13.00 CX35-30/36B EL195UH070XE36B 8260731 14ACXS024-230A TXV 23,400 15.50 12.50 CX35-30/36B EL296UH045XE36B 8260733 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30/36B EL296UH045XV36B 8260736 14ACXS024-230A TXV 23,600 16.00 13.00 CX35-30/36B EL296UH070XE36B 8260735 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30/36B EL296UH070XV36B 8260725 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30/36B SL280UH090V36B 8260738 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30/36B SL280UH090V48B 8260739 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30/36B SL280UH090XV48B 8260741 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30/36B SLP98UH070XV36B 8260726 14ACXS024-230A TXV 23,800 14.50 12.00 CX35-30/36B 8260723 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30/36C EL296UH090XV36C 8260747 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30/36C SLP98UH090XV36C 8260749 14ACXS024-230A TXV 23,800 14.50 12.00 CX35-30/36C 8260746 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30A EL180UH045E36A 8260689 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30A EL180UH045XE36A 8260691 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30A SL280UH070V36A 8260686 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30A SL280UH070XV36A 8260688 14ACXS024-230A TXV 24,000 14.50 12.20 CX35-30A 8260684 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30B EL180UH070E36B 8260703 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30B EL180UH070XE36B 8260704 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30B EL195UH030XE24B 8606607 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30B EL195UH045XE24B 8606609 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30B EL195UH045XE36B 8260706 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30B EL195UH070XE36B 8260708 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30B EL296UH045XE36B 8260709 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30B EL296UH045XV36B 8260696 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30B EL296UH070XE36B 8260694 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30B EL296UH070XV36B 8260698 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30B SL280UH090V36B 8260711 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30B SL280UH090V48B 8260713 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30B SL280UH090XV48B 8260701 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-30B SLP98UH070XV36B 8260699 14ACXS024-230A TXV 24,000 14.50 12.20 CX35-30B 8260693 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-36A EL180UH045E36A 8260752 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-36A EL180UH045XE36A 8260754 14ACXS024-230A TXV 24,000 16.00 13.50 CX35-36A SL280UH070V36A 8260756 14ACXS024-230A TXV 24,000 16.00 13.50 CX35-36A SL280UH070XV36A 8260757 14ACXS024-230A TXV 24,000 14.50 12.50 CX35-36A 8260751 14ACXS024-230A TXV 24,000 16.00 13.50 CX35-36B EL180UH070E36B 8260779 14ACXS024-230A TXV 24,000 16.00 13.50 CX35-36B EL180UH070XE36B 8260764 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 69 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-36B EL195UH030XE24B 8606610 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-36B EL195UH045XE24B 8606612 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-36B EL195UH045XE36B 8260766 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-36B EL195UH070XE36B 8260767 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-36B EL296UH045XE36B 8260769 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-36B EL296UH045XV36B 8260772 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-36B EL296UH070XE36B 8260771 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-36B EL296UH070XV36B 8260761 14ACXS024-230A TXV 24,000 16.00 13.50 CX35-36B SL280UH090V36B 8260774 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-36B SL280UH090V48B 8260776 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-36B SL280UH090XV48B 8260778 14ACXS024-230A TXV 24,000 16.00 13.00 CX35-36B SLP98UH070XV36B 8260763 14ACXS024-230A TXV 24,000 14.50 12.50 CX35-36B 8260759 14ACXS030-230A RFC 27,400 14.00 12.00 C33-25A 7625420 14ACXS030-230A RFC 27,400 14.00 12.00 C33-25B 7625426 14ACXS030-230A RFC 28,000 14.25 12.20 C33-31A 7625468 14ACXS030-230A RFC 28,000 14.25 12.20 C33-31B 7625478 14ACXS030-230A RFC 28,000 14.25 12.20 C33-38A 7625534 14ACXS030-230A RFC 28,000 14.25 12.20 C33-38B 7625543 14ACXS030-230A RFC 28,000 14.50 12.20 C33-43 7628235 14ACXS030-230A RFC 27,400 14.00 12.00 C35-24A 8471068 14ACXS030-230A RFC 27,400 14.00 12.00 C35-24B 8471069 14ACXS030-230A RFC 28,000 14.00 12.20 C35-30A 8471032 14ACXS030-230A RFC 28,000 14.00 12.20 C35-30B 8471035 14ACXS030-230A RFC 28,000 14.00 12.20 C35-36A 8471038 14ACXS030-230A RFC 28,000 14.00 12.20 C35-36B 8471041 14ACXS030-230A RFC 27,400 14.00 12.20 C35-48B 8471043 14ACXS030-230A RFC 27,400 14.00 12.20 C35-48C 8471045 14ACXS030-230A RFC 27,600 14.00 12.00 CH33-25A 7625653 14ACXS030-230A RFC 28,000 14.25 12.20 CH33-31A 7625682 14ACXS030-230A RFC 28,000 14.25 12.20 CH33-31B 7625692 14ACXS030-230A RFC 27,600 14.00 12.00 CH33-36C 7625744 14ACXS030-230A RFC 28,000 14.00 12.20 CH33-42B 7625754 14ACXS030-230A RFC 28,000 14.50 12.50 CH33-43B 7625756 14ACXS030-230A RFC 27,800 14.00 12.00 CR33-30/36A 7625891 14ACXS030-230A RFC 27,800 14.00 12.00 CR33-30/36B 7625898 14ACXS030-230A RFC 27,800 14.00 12.00 CR33-30/36C 7625919 14ACXS030-230A TXV 28,000 15.10 12.50 C33-25A EL180UH045E36A 7625424 14ACXS030-230A TXV 28,000 15.10 12.50 C33-25A EL180UH045XE36A 7625425 14ACXS030-230A TXV 28,000 15.50 12.50 C33-25A SL280UH070V36A 7625422 14ACXS030-230A TXV 28,000 15.50 12.50 C33-25A SL280UH070XV36A 7625423 14ACXS030-230A TXV 27,600 14.00 12.00 C33-25A 7625421 14ACXS030-230A TXV 28,000 15.50 12.50 C33-25B EL180UH070E36B 7625431 14ACXS030-230A TXV 28,000 15.50 12.50 C33-25B EL180UH070XE36B 7625432 14ACXS030-230A TXV 27,800 15.50 12.50 C33-25B EL180UH090E48B 7625428 14ACXS030-230A TXV 27,800 15.50 12.50 C33-25B EL180UH090XE48B 7625429 14ACXS030-230A TXV 28,000 15.10 12.50 C33-25B EL195UH045XE36B 7625433 14ACXS030-230A TXV 28,000 15.00 12.50 C33-25B EL195UH070XE36B 7625436 14ACXS030-230A TXV 28,000 15.10 12.50 C33-25B EL296UH045XE36B 7625434 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 70 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS030-230A TXV 28,000 15.00 12.50 C33-25B EL296UH070XE36B 7625437 14ACXS030-230A TXV 28,000 15.10 12.50 C33-25B EL296UH070XV36B 7625439 14ACXS030-230A TXV 28,000 15.50 12.50 C33-25B SL280UH090V36B 7625430 14ACXS030-230A TXV 28,000 15.10 12.50 C33-25B SLP98UH070XV36B 7625441 14ACXS030-230A TXV 27,600 14.00 12.00 C33-25B 7625427 14ACXS030-230A TXV 27,400 15.00 12.50 C33-30A EL180UH045E36A 7625453 14ACXS030-230A TXV 27,400 15.00 12.50 C33-30A EL180UH045XE36A 7625454 14ACXS030-230A TXV 27,400 15.00 12.50 C33-30A SL280UH070V36A 7625449 14ACXS030-230A TXV 27,400 15.00 12.50 C33-30A SL280UH070XV36A 7625451 14ACXS030-230A TXV 27,400 15.10 12.50 C33-30B EL180UH070E36B 7625456 14ACXS030-230A TXV 27,400 15.10 12.50 C33-30B EL180UH070XE36B 7625458 14ACXS030-230A TXV 27,200 15.10 12.50 C33-30B EL180UH090E48B 7625442 14ACXS030-230A TXV 27,200 15.10 12.50 C33-30B EL180UH090XE48B 7625444 14ACXS030-230A TXV 27,200 14.50 12.50 C33-30B EL195UH045XE36B 7625446 14ACXS030-230A TXV 27,400 14.50 12.50 C33-30B EL195UH070XE36B 7625459 14ACXS030-230A TXV 27,200 14.50 12.50 C33-30B EL296UH045XE36B 7625447 14ACXS030-230A TXV 27,400 14.50 12.50 C33-30B EL296UH070XE36B 7625461 14ACXS030-230A TXV 27,400 15.00 12.50 C33-30B EL296UH070XV36B 7625463 14ACXS030-230A TXV 27,600 15.10 12.50 C33-30B SL280UH090V36B 7625466 14ACXS030-230A TXV 27,400 15.00 12.50 C33-30B SLP98UH070XV36B 7625465 14ACXS030-230A TXV 27,400 15.10 12.50 C33-30C SLP98UH090XV36C 7783132 14ACXS030-230A TXV 28,000 15.50 12.50 C33-31A EL180UH045E36A 7625475 14ACXS030-230A TXV 28,000 15.50 12.50 C33-31A EL180UH045XE36A 7625477 14ACXS030-230A TXV 28,000 16.00 13.00 C33-31A SL280UH070V36A 7625472 14ACXS030-230A TXV 28,000 16.00 13.00 C33-31A SL280UH070XV36A 7625473 14ACXS030-230A TXV 28,000 14.25 12.20 C33-31A 7625470 14ACXS030-230A TXV 28,000 16.00 13.00 C33-31B EL180UH070E36B 7625483 14ACXS030-230A TXV 28,000 16.00 13.00 C33-31B EL180UH070XE36B 7625485 14ACXS030-230A TXV 28,000 16.00 13.00 C33-31B EL180UH090E48B 7625487 14ACXS030-230A TXV 28,000 16.00 13.00 C33-31B EL180UH090XE48B 7625488 14ACXS030-230A TXV 28,000 15.50 12.50 C33-31B EL195UH045XE36B 7625490 14ACXS030-230A TXV 28,000 15.10 12.50 C33-31B EL195UH070XE36B 7625493 14ACXS030-230A TXV 28,000 15.50 12.50 C33-31B EL296UH045XE36B 7625491 14ACXS030-230A TXV 28,000 15.10 12.50 C33-31B EL296UH070XE36B 7625495 14ACXS030-230A TXV 28,000 16.00 13.00 C33-31B EL296UH070XV36B 7625496 14ACXS030-230A TXV 28,000 16.00 13.00 C33-31B SL280UH090V36B 7625482 14ACXS030-230A TXV 28,000 16.00 13.00 C33-31B SLP98UH070XV36B 7625498 14ACXS030-230A TXV 28,000 14.25 12.20 C33-31B 7625480 14ACXS030-230A TXV 28,000 15.10 12.50 C33-36A EL180UH045E36A 7625504 14ACXS030-230A TXV 28,000 15.10 12.50 C33-36A EL180UH045XE36A 7625506 14ACXS030-230A TXV 28,000 15.50 12.50 C33-36A SL280UH070V36A 7625501 14ACXS030-230A TXV 28,000 15.50 12.50 C33-36A SL280UH070XV36A 7625503 14ACXS030-230A TXV 27,600 14.00 12.00 C33-36A 7625500 14ACXS030-230A TXV 28,000 15.50 12.50 C33-36B EL180UH070E36B 7625513 14ACXS030-230A TXV 28,000 15.50 12.50 C33-36B EL180UH070XE36B 7625514 14ACXS030-230A TXV 28,000 15.50 12.50 C33-36B EL180UH090E48B 7625516 14ACXS030-230A TXV 28,000 15.50 12.50 C33-36B EL180UH090XE48B 7625517 14ACXS030-230A TXV 28,000 15.10 12.50 C33-36B EL195UH045XE36B 7625519 14ACXS030-230A TXV 28,000 15.10 12.50 C33-36B EL195UH070XE36B 7625522 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 71 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS030-230A TXV 28,000 15.10 12.50 C33-36B EL296UH045XE36B 7625521 14ACXS030-230A TXV 27,800 15.10 12.50 C33-36B EL296UH045XV36B 7628214 14ACXS030-230A TXV 28,000 15.10 12.50 C33-36B EL296UH070XE36B 7625524 14ACXS030-230A TXV 28,000 15.50 12.50 C33-36B EL296UH070XV36B 7625509 14ACXS030-230A TXV 28,000 15.50 12.50 C33-36B SL280UH090V36B 7625511 14ACXS030-230A TXV 28,000 15.50 12.50 C33-36B SLP98UH070XV36B 7625525 14ACXS030-230A TXV 27,600 14.00 12.00 C33-36B 7625508 14ACXS030-230A TXV 28,000 15.10 12.50 C33-36C EL195UH090XE48C 7625527 14ACXS030-230A TXV 28,000 15.10 12.50 C33-36C EL296UH090XE48C 7625529 14ACXS030-230A TXV 28,000 15.50 12.50 C33-36C EL296UH090XV36C 7625530 14ACXS030-230A TXV 28,000 15.50 12.50 C33-36C SLP98UH090XV36C 7625532 14ACXS030-230A TXV 28,000 16.00 13.00 C33-38A EL180UH045E36A 7625540 14ACXS030-230A TXV 28,000 16.00 13.00 C33-38A EL180UH045XE36A 7625542 14ACXS030-230A TXV 28,000 16.00 13.00 C33-38A SL280UH070V36A 7625537 14ACXS030-230A TXV 28,000 16.00 13.00 C33-38A SL280UH070XV36A 7625538 14ACXS030-230A TXV 28,000 14.50 12.20 C33-38A 7625535 14ACXS030-230A TXV 28,000 16.00 13.00 C33-38B EL180UH070E36B 7625548 14ACXS030-230A TXV 28,000 16.00 13.00 C33-38B EL180UH070XE36B 7625550 14ACXS030-230A TXV 28,000 16.00 13.00 C33-38B EL180UH090E48B 7625552 14ACXS030-230A TXV 28,000 16.00 13.00 C33-38B EL180UH090XE48B 7625553 14ACXS030-230A TXV 28,000 15.50 12.50 C33-38B EL195UH045XE36B 7625555 14ACXS030-230A TXV 28,000 15.50 12.50 C33-38B EL195UH070XE36B 7625558 14ACXS030-230A TXV 28,000 15.50 12.50 C33-38B EL296UH045XE36B 7625556 14ACXS030-230A TXV 28,000 15.50 12.50 C33-38B EL296UH045XV36B 7625561 14ACXS030-230A TXV 28,000 15.50 12.50 C33-38B EL296UH070XE36B 7625560 14ACXS030-230A TXV 28,000 16.00 13.00 C33-38B EL296UH070XV36B 7625563 14ACXS030-230A TXV 28,000 16.00 13.00 C33-38B SL280UH090V36B 7625547 14ACXS030-230A TXV 28,000 16.00 13.00 C33-38B SLP98UH070XV36B 7625564 14ACXS030-230A TXV 28,000 14.50 12.20 C33-38B 7625545 14ACXS030-230A TXV 28,000 16.00 13.00 C33-42 EL180UH070E36B 7783134 14ACXS030-230A TXV 28,000 16.00 13.00 C33-42 EL180UH070XE36B 7628220 14ACXS030-230A TXV 28,000 16.00 13.00 C33-42 EL180UH090E48B 7783135 14ACXS030-230A TXV 28,000 16.00 13.00 C33-42 EL180UH090XE48B 7628223 14ACXS030-230A TXV 28,000 15.50 12.50 C33-42 EL195UH045XE36B 7783136 14ACXS030-230A TXV 28,000 15.50 12.50 C33-42 EL195UH070XE36B 7783137 14ACXS030-230A TXV 28,000 15.50 12.50 C33-42 EL296UH045XE36B 7628226 14ACXS030-230A TXV 28,000 15.50 12.50 C33-42 EL296UH045XV36B 7783138 14ACXS030-230A TXV 28,000 15.50 12.50 C33-42 EL296UH070XE36B 7628229 14ACXS030-230A TXV 28,000 16.00 13.00 C33-42 EL296UH070XV36B 7628232 14ACXS030-230A TXV 28,000 15.50 12.50 C33-42 SL280UH090V36B 7628217 14ACXS030-230A TXV 28,000 16.00 13.00 C33-42 SLP98UH070XV36B 7783139 14ACXS030-230A TXV 27,600 14.00 12.00 C33-42 7783133 14ACXS030-230A TXV 28,000 16.00 13.00 C33-43B EL180UH070E36B 7625569 14ACXS030-230A TXV 28,000 16.00 13.00 C33-43B EL180UH070XE36B 7625571 14ACXS030-230A TXV 28,000 16.00 13.00 C33-43B EL180UH090E48B 7625573 14ACXS030-230A TXV 28,000 16.00 13.00 C33-43B EL180UH090XE48B 7625574 14ACXS030-230A TXV 28,000 15.50 12.50 C33-43B EL195UH045XE36B 7625576 14ACXS030-230A TXV 28,000 15.50 12.50 C33-43B EL195UH070XE36B 7625579 14ACXS030-230A TXV 28,000 15.50 12.50 C33-43B EL296UH045XE36B 7625577 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 72 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS030-230A TXV 28,000 15.50 12.50 C33-43B EL296UH045XV36B 7625582 14ACXS030-230A TXV 28,000 15.50 12.50 C33-43B EL296UH070XE36B 7625581 14ACXS030-230A TXV 28,000 16.00 13.00 C33-43B EL296UH070XV36B 7625584 14ACXS030-230A TXV 28,000 16.00 13.00 C33-43B SL280UH090V36B 7625568 14ACXS030-230A TXV 28,000 16.00 13.00 C33-43B SLP98UH070XV36B 7625585 14ACXS030-230A TXV 28,000 14.50 12.20 C33-43B 7625566 14ACXS030-230A TXV 28,000 16.00 13.00 C33-43C EL195UH090XE48C 7625589 14ACXS030-230A TXV 28,000 16.00 13.00 C33-43C EL296UH090XE48C 7625590 14ACXS030-230A TXV 28,000 16.00 13.00 C33-43C EL296UH090XV36C 7625592 14ACXS030-230A TXV 28,000 16.00 13.00 C33-43C EL296UH090XV48C 7625595 14ACXS030-230A TXV 28,000 16.00 13.00 C33-43C SLP98UH090XV36C 7625594 14ACXS030-230A TXV 28,000 16.00 13.00 C33-43C SLP98UH090XV48C 7625597 14ACXS030-230A TXV 28,000 14.50 12.20 C33-43C 7625587 14ACXS030-230A TXV 28,000 15.10 12.50 C35-24A EL180UH045E36A 8260887 14ACXS030-230A TXV 28,000 15.10 12.50 C35-24A EL180UH045XE36A 8260888 14ACXS030-230A TXV 28,000 15.50 12.50 C35-24A SL280UH070V36A 8260883 14ACXS030-230A TXV 28,000 15.50 12.50 C35-24A SL280UH070XV36A 8260885 14ACXS030-230A TXV 27,600 14.00 12.00 C35-24A 8260882 14ACXS030-230A TXV 28,000 15.50 12.50 C35-24B EL180UH070E36B 8259755 14ACXS030-230A TXV 28,000 15.50 12.50 C35-24B EL180UH070XE36B 8259757 14ACXS030-230A TXV 27,800 15.50 12.50 C35-24B EL180UH090E48B 8259746 14ACXS030-230A TXV 27,800 15.50 12.50 C35-24B EL180UH090XE48B 8259747 14ACXS030-230A TXV 28,000 15.10 12.50 C35-24B EL195UH045XE36B 8259759 14ACXS030-230A TXV 28,000 15.00 12.50 C35-24B EL195UH070XE36B 8259762 14ACXS030-230A TXV 28,000 15.10 12.50 C35-24B EL296UH045XE36B 8259760 14ACXS030-230A TXV 28,000 15.00 12.50 C35-24B EL296UH070XE36B 8259749 14ACXS030-230A TXV 28,000 15.10 12.50 C35-24B EL296UH070XV36B 8259751 14ACXS030-230A TXV 28,000 15.50 12.50 C35-24B SL280UH090V36B 8259754 14ACXS030-230A TXV 28,000 15.10 12.50 C35-24B SLP98UH070XV36B 8259752 14ACXS030-230A TXV 27,600 14.00 12.00 C35-24B 8259744 14ACXS030-230A TXV 28,000 15.10 12.50 C35-30/36A EL180UH045E36A 8259799 14ACXS030-230A TXV 28,000 15.10 12.50 C35-30/36A EL180UH045XE36A 8259794 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30/36A SL280UH070V36A 8259795 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30/36A SL280UH070XV36A 8259797 14ACXS030-230A TXV 27,600 14.00 12.00 C35-30/36A 8259792 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30/36B EL180UH070E36B 8259817 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30/36B EL180UH070XE36B 8259818 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30/36B EL180UH090E48B 8259820 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30/36B EL180UH090XE48B 8259803 14ACXS030-230A TXV 28,000 15.10 12.50 C35-30/36B EL195UH045XE36B 8259805 14ACXS030-230A TXV 28,000 15.10 12.50 C35-30/36B EL195UH070XE36B 8259808 14ACXS030-230A TXV 28,000 15.10 12.50 C35-30/36B EL296UH045XE36B 8259807 14ACXS030-230A TXV 27,800 15.10 12.50 C35-30/36B EL296UH045XV36B 8259802 14ACXS030-230A TXV 28,000 15.10 12.50 C35-30/36B EL296UH070XE36B 8259810 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30/36B EL296UH070XV36B 8259813 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30/36B SL280UH090V36B 8259815 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30/36B SLP98UH070XV36B 8259812 14ACXS030-230A TXV 27,600 14.00 12.00 C35-30/36B 8259800 14ACXS030-230A TXV 28,000 15.10 12.50 C35-30/36C EL195UH090XE48C 8259822 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 73 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS030-230A TXV 28,000 15.10 12.50 C35-30/36C EL296UH090XE48C 8259823 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30/36C EL296UH090XV36C 8259825 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30/36C SLP98UH090XV36C 8259826 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30A EL180UH045E36A 8259769 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30A EL180UH045XE36A 8259770 14ACXS030-230A TXV 28,000 16.00 13.00 C35-30A SL280UH070V36A 8259766 14ACXS030-230A TXV 28,000 16.00 13.00 C35-30A SL280UH070XV36A 8259767 14ACXS030-230A TXV 28,000 14.25 12.20 C35-30A 8259764 14ACXS030-230A TXV 28,000 16.00 13.00 C35-30B EL180UH070E36B 8259790 14ACXS030-230A TXV 28,000 16.00 13.00 C35-30B EL180UH070XE36B 8259779 14ACXS030-230A TXV 28,000 16.00 13.00 C35-30B EL180UH090E48B 8259780 14ACXS030-230A TXV 28,000 16.00 13.00 C35-30B EL180UH090XE48B 8259782 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30B EL195UH045XE36B 8259784 14ACXS030-230A TXV 28,000 15.10 12.50 C35-30B EL195UH070XE36B 8259787 14ACXS030-230A TXV 28,000 15.50 12.50 C35-30B EL296UH045XE36B 8259785 14ACXS030-230A TXV 28,000 15.10 12.50 C35-30B EL296UH070XE36B 8259774 14ACXS030-230A TXV 28,000 16.00 13.00 C35-30B EL296UH070XV36B 8259775 14ACXS030-230A TXV 28,000 16.00 13.00 C35-30B SL280UH090V36B 8259789 14ACXS030-230A TXV 28,000 16.00 13.00 C35-30B SLP98UH070XV36B 8259777 14ACXS030-230A TXV 28,000 14.25 12.20 C35-30B 8259772 14ACXS030-230A TXV 28,000 16.00 13.00 C35-36A EL180UH045E36A 8259830 14ACXS030-230A TXV 28,000 16.00 13.00 C35-36A EL180UH045XE36A 8259832 14ACXS030-230A TXV 28,000 16.00 13.00 C35-36A SL280UH070V36A 8259834 14ACXS030-230A TXV 28,000 16.00 13.00 C35-36A SL280UH070XV36A 8259836 14ACXS030-230A TXV 28,000 14.25 12.20 C35-36A 8259828 14ACXS030-230A TXV 28,000 16.00 13.00 C35-36B EL180UH070E36B 8259854 14ACXS030-230A TXV 28,000 16.00 13.00 C35-36B EL180UH070XE36B 8259855 14ACXS030-230A TXV 28,000 16.00 13.00 C35-36B EL180UH090E48B 8259857 14ACXS030-230A TXV 28,000 16.00 13.00 C35-36B EL180UH090XE48B 8259842 14ACXS030-230A TXV 28,000 15.50 12.50 C35-36B EL195UH045XE36B 8259844 14ACXS030-230A TXV 28,000 15.50 12.50 C35-36B EL195UH070XE36B 8259847 14ACXS030-230A TXV 28,000 15.50 12.50 C35-36B EL296UH045XE36B 8259845 14ACXS030-230A TXV 28,000 15.50 12.50 C35-36B EL296UH045XV36B 8259850 14ACXS030-230A TXV 28,000 15.50 12.50 C35-36B EL296UH070XE36B 8259849 14ACXS030-230A TXV 28,000 16.00 13.00 C35-36B EL296UH070XV36B 8259839 14ACXS030-230A TXV 28,000 16.00 13.00 C35-36B SL280UH090V36B 8259852 14ACXS030-230A TXV 28,000 16.00 13.00 C35-36B SLP98UH070XV36B 8259841 14ACXS030-230A TXV 28,000 14.50 12.20 C35-36B 8259837 14ACXS030-230A TXV 28,000 16.00 13.00 C35-48B EL180UH070E36B 8259875 14ACXS030-230A TXV 28,000 16.00 13.00 C35-48B EL180UH070XE36B 8259877 14ACXS030-230A TXV 28,000 16.00 13.00 C35-48B EL180UH090E48B 8259878 14ACXS030-230A TXV 28,000 16.00 13.00 C35-48B EL180UH090XE48B 8259864 14ACXS030-230A TXV 28,000 15.50 12.50 C35-48B EL195UH045XE36B 8259865 14ACXS030-230A TXV 28,000 15.50 12.50 C35-48B EL195UH070XE36B 8259869 14ACXS030-230A TXV 28,000 15.50 12.50 C35-48B EL296UH045XE36B 8259867 14ACXS030-230A TXV 28,000 15.50 12.50 C35-48B EL296UH045XV36B 8259872 14ACXS030-230A TXV 28,000 15.50 12.50 C35-48B EL296UH070XE36B 8259870 14ACXS030-230A TXV 28,000 16.00 13.00 C35-48B EL296UH070XV36B 8259860 14ACXS030-230A TXV 28,000 16.00 13.00 C35-48B SL280UH090V36B 8259873 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 74 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS030-230A TXV 28,000 16.00 13.00 C35-48B SLP98UH070XV36B 8259862 14ACXS030-230A TXV 28,000 14.50 12.20 C35-48B 8259859 14ACXS030-230A TXV 28,000 16.00 13.00 C35-48C EL195UH090XE48C 8259885 14ACXS030-230A TXV 28,000 16.00 13.00 C35-48C EL296UH090XE48C 8259887 14ACXS030-230A TXV 28,000 16.00 13.00 C35-48C EL296UH090XV36C 8259888 14ACXS030-230A TXV 28,000 16.00 13.00 C35-48C EL296UH090XV48C 8259882 14ACXS030-230A TXV 28,000 16.00 13.00 C35-48C SLP98UH090XV36C 8259890 14ACXS030-230A TXV 28,000 16.00 13.00 C35-48C SLP98UH090XV48C 8259883 14ACXS030-230A TXV 28,000 14.50 12.20 C35-48C 8259880 14ACXS030-230A TXV 28,600 16.00 13.00 CBA27UHE-030 10259390 14ACXS030-230A TXV 28,600 16.00 13.00 CBA27UHE-036 10259391 14ACXS030-230A TXV 27,800 14.00 12.00 CBX25UH-030 7625598 14ACXS030-230A TXV 28,000 14.50 12.20 CBX25UH-036 7625600 14ACXS030-230A TXV 28,000 15.10 12.50 CBX25UHV-030 7625602 14ACXS030-230A TXV 28,000 15.10 12.50 CBX25UHV-036 7625603 14ACXS030-230A TXV 28,000 16.00 13.00 CBX27UH-030 7625605 14ACXS030-230A TXV 28,000 16.00 13.00 CBX27UH-036 7625606 14ACXS030-230A TXV 28,000 15.00 12.50 CBX32M-030 7625608 14ACXS030-230A TXV 28,000 15.00 12.50 CBX32M-036 7625610 14ACXS030-230A TXV 28,000 14.50 12.50 CBX32MV-024/030 7625611 14ACXS030-230A TXV 28,000 15.10 12.50 CBX32MV-036 7625613 14ACXS030-230A TXV 28,000 15.10 12.50 CBX40UHV-030 7625614 14ACXS030-230A TXV 28,000 15.50 12.50 CBX40UHV-036 7783140 14ACXS030-230A TXV 26,800 15.00 12.50 CH23-31 EL180UH070E36B 7628239 14ACXS030-230A TXV 26,800 15.00 12.50 CH23-31 EL180UH070XE36B 7783141 14ACXS030-230A TXV 26,800 15.00 12.50 CH23-31 EL180UH090E48B 7783227 14ACXS030-230A TXV 26,800 15.00 12.50 CH23-31 EL180UH090XE48B 7628535 14ACXS030-230A TXV 26,600 14.25 12.20 CH23-31 EL195UH045XE36B 7783226 14ACXS030-230A TXV 26,600 14.25 14.60 CH23-31 EL195UH070XE36B 7783228 14ACXS030-230A TXV 26,600 14.25 12.20 CH23-31 EL296UH045XE36B 7628532 14ACXS030-230A TXV 26,600 14.50 12.20 CH23-31 EL296UH045XV36B 7625616 14ACXS030-230A TXV 26,600 14.25 14.60 CH23-31 EL296UH070XE36B 7628538 14ACXS030-230A TXV 26,800 14.50 12.50 CH23-31 EL296UH070XV36B 7625619 14ACXS030-230A TXV 26,800 15.10 12.50 CH23-31 SL280UH090V36B 7625618 14ACXS030-230A TXV 26,800 14.50 12.50 CH23-31 SLP98UH070XV36B 7625621 14ACXS030-230A TXV 28,000 15.50 12.50 CH23-41 EL180UH045E36A 7625626 14ACXS030-230A TXV 28,000 15.50 12.50 CH23-41 EL180UH045XE36A 7625627 14ACXS030-230A TXV 28,000 15.50 12.50 CH23-41 EL180UH070E36B 7625629 14ACXS030-230A TXV 28,000 15.50 12.50 CH23-41 EL180UH070XE36B 7625631 14ACXS030-230A TXV 28,000 16.00 13.00 CH23-41 EL180UH090E48B 7625632 14ACXS030-230A TXV 28,000 16.00 13.00 CH23-41 EL180UH090XE48B 7625634 14ACXS030-230A TXV 28,000 15.10 12.50 CH23-41 EL195UH045XE36B 7625635 14ACXS030-230A TXV 28,000 15.10 12.50 CH23-41 EL195UH070XE36B 7625639 14ACXS030-230A TXV 28,000 15.10 12.50 CH23-41 EL296UH045XE36B 7625637 14ACXS030-230A TXV 28,000 15.10 12.50 CH23-41 EL296UH045XV36B 7625642 14ACXS030-230A TXV 28,000 15.10 12.50 CH23-41 EL296UH070XE36B 7625640 14ACXS030-230A TXV 28,000 15.50 12.50 CH23-41 EL296UH070XV36B 7625643 14ACXS030-230A TXV 28,000 16.00 13.00 CH23-41 SL280UH090V36B 7625624 14ACXS030-230A TXV 28,000 15.50 12.50 CH23-41 SLP98UH070XV36B 7625645 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 75 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS030-230A TXV 27,800 14.00 12.00 CH23-41 7625623 14ACXS030-230A TXV 27,400 15.00 12.50 CH33-19 EL180UH045E36A 7625647 14ACXS030-230A TXV 27,400 15.00 12.50 CH33-19 EL180UH045XE36A 7625648 14ACXS030-230A TXV 27,600 15.10 12.50 CH33-19 SL280UH070V36A 7625650 14ACXS030-230A TXV 27,600 15.10 12.50 CH33-19 SL280UH070XV36A 7625651 14ACXS030-230A TXV 27,400 15.00 12.50 CH33-24/30 EL180UH045E36A 7628245 14ACXS030-230A TXV 27,400 15.00 12.50 CH33-24/30 EL180UH045XE36A 7783143 14ACXS030-230A TXV 27,400 15.00 12.50 CH33-24/30 SL280UH070V36A 7628242 14ACXS030-230A TXV 27,400 15.00 12.50 CH33-24/30 SL280UH070XV36A 7783142 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-25A EL180UH045E36A 7625660 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-25A EL180UH045XE36A 7625661 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-25A SL280UH070V36A 7625657 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-25A SL280UH070XV36A 7625658 14ACXS030-230A TXV 27,800 14.00 12.00 CH33-25A 7625655 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-25B EL180UH070E36B 7625666 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-25B EL180UH070XE36B 7625668 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-25B EL180UH090E48B 7625669 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-25B EL180UH090XE48B 7625671 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-25B EL195UH045XE36B 7625673 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-25B EL195UH070XE36B 7625676 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-25B EL296UH045XE36B 7628248 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-25B EL296UH045XV36B 7625674 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-25B EL296UH070XE36B 7625677 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-25B EL296UH070XV36B 7625679 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-25B SL280UH090V36B 9150359 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-25B SLP98UH070XV36B 7625681 14ACXS030-230A TXV 27,600 14.00 12.00 CH33-25B 7625663 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-31A EL180UH045E36A 7625689 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-31A EL180UH045XE36A 7625691 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-31A SL280UH070V36A 7625686 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-31A SL280UH070XV36A 7625687 14ACXS030-230A TXV 28,000 14.25 12.20 CH33-31A 7625684 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-31B EL180UH070E36B 7625697 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-31B EL180UH070XE36B 7625699 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-31B EL180UH090E48B 7625700 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-31B EL180UH090XE48B 7625702 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-31B EL195UH045XE36B 7625704 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-31B EL195UH070XE36B 7625707 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-31B EL296UH045XE36B 7625705 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-31B EL296UH045XV36B 7625710 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-31B EL296UH070XE36B 7625708 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-31B EL296UH070XV36B 7625712 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-31B SL280UH090V36B 7625696 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-31B SLP98UH070XV36B 7625713 14ACXS030-230A TXV 28,000 14.50 12.20 CH33-31B 7625694 14ACXS030-230A TXV 27,800 15.10 12.50 CH33-36A EL180UH045E36A 7625717 14ACXS030-230A TXV 27,800 15.10 12.50 CH33-36A EL180UH045XE36A 7625718 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-36A SL280UH070V36A 7625720 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-36A SL280UH070XV36A 7625721 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 76 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS030-230A TXV 27,400 14.00 11.50 CH33-36A 7625715 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-36B EL180UH070E36B 7625728 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-36B EL180UH070XE36B 7625730 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-36B EL180UH090E48B 7625731 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-36B EL180UH090XE48B 7625733 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-36B EL195UH045XE36B 7625734 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-36B EL195UH070XE36B 7625738 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-36B EL296UH045XE36B 7625736 14ACXS030-230A TXV 27,800 15.10 12.50 CH33-36B EL296UH045XV36B 7625725 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-36B EL296UH070XE36B 7625739 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-36B SL280UH090V36B 7625726 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-36B SLP98UH070XV36B 7625743 14ACXS030-230A TXV 27,600 14.00 11.50 CH33-36B 7625723 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-36C EL195UH090XE48C 7625748 14ACXS030-230A TXV 28,000 15.10 12.50 CH33-36C EL296UH090XE48C 7625749 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-36C EL296UH090XV36C 7625751 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-36C SLP98UH090XV36C 7625752 14ACXS030-230A TXV 27,800 14.00 12.00 CH33-36C 7625746 14ACXS030-230A TXV 28,000 14.25 12.20 CH33-42 7783144 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-42B EL180UH070E36B 7783145 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-42B EL180UH070XE36B 7628255 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-42B EL180UH090E48B 7783146 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-42B EL180UH090XE48B 7628258 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-42B EL195UH045XE36B 7783147 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-42B EL195UH070XE36B 7783148 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-42B EL296UH045XE36B 7628261 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-42B EL296UH045XV36B 7783149 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-42B EL296UH070XE36B 7628264 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-42B EL296UH070XV36B 7628267 14ACXS030-230A TXV 28,000 15.50 12.50 CH33-42B SLP98UH070XV36B 7783150 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43B EL180UH070E36B 7625761 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43B EL180UH070XE36B 7625762 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43B EL180UH090E48B 7625764 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43B EL180UH090XE48B 7625766 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43B EL195UH045XE36B 7625767 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43B EL195UH070XE36B 7625770 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43B EL296UH045XE36B 7625769 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43B EL296UH045XV36B 7625774 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43B EL296UH070XE36B 7625772 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43B EL296UH070XV36B 7625775 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43B SL280UH090V36B 7625759 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43B SLP98UH070XV36B 7625777 14ACXS030-230A TXV 28,000 14.50 12.50 CH33-43B 7625758 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43C EL195UH090XE48C 7625780 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43C EL296UH090XE48C 7625782 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43C EL296UH090XV36C 7625783 14ACXS030-230A TXV 28,000 16.00 13.00 CH33-43C SLP98UH090XV36C 7625785 14ACXS030-230A TXV 28,000 14.50 12.20 CH33-43C 7625779 14ACXS030-230A TXV 27,800 14.00 12.00 CH35-24A 7629938 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 77 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-24B EL180UH070E36B 7625825 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-30A EL180UH045E36A 7625790 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-30A EL180UH045XE36A 7625791 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-30A SL280UH070V36A 7625787 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-30A SL280UH070XV36A 7625788 14ACXS030-230A TXV 28,000 14.25 12.20 CH35-30A 7783665 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-30B EL180UH070E36B 7625796 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-30B EL180UH070XE36B 7625798 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-30B EL180UH090E48B 7625799 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-30B EL180UH090XE48B 7625801 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-30B EL195UH045XE36B 7625803 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-30B EL195UH070XE36B 7625806 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-30B EL296UH045XE36B 7625809 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-30B EL296UH045XV36B 7625804 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-30B EL296UH070XE36B 7625807 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-30B EL296UH070XV36B 7625811 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-30B SL280UH090V36B 7625795 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-30B SLP98UH070XV36B 7625812 14ACXS030-230A TXV 28,000 14.50 12.20 CH35-30B 7625793 14ACXS030-230A TXV 28,000 15.10 12.50 CH35-36A EL180UH045E36A 7625819 14ACXS030-230A TXV 28,000 15.10 12.50 CH35-36A EL180UH045XE36A 7625820 14ACXS030-230A TXV 28,000 15.10 12.50 CH35-36A SL280UH070V36A 7625816 14ACXS030-230A TXV 28,000 15.10 12.50 CH35-36A SL280UH070XV36A 7625817 14ACXS030-230A TXV 27,600 14.00 12.00 CH35-36A 7625814 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-36B EL180UH070E36B 7625827 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-36B EL180UH090E48B 7625829 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-36B EL180UH090XE48B 7625830 14ACXS030-230A TXV 28,000 15.10 12.50 CH35-36B EL195UH045XE36B 7625832 14ACXS030-230A TXV 28,000 15.10 12.50 CH35-36B EL195UH070XE36B 7625836 14ACXS030-230A TXV 28,000 15.10 12.50 CH35-36B EL296UH045XE36B 7625834 14ACXS030-230A TXV 28,000 15.10 12.50 CH35-36B EL296UH045XV36B 7625839 14ACXS030-230A TXV 28,000 15.10 12.50 CH35-36B EL296UH070XE36B 7625837 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-36B EL296UH070XV36B 7625841 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-36B SL280UH090V36B 7625824 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-36B SLP98UH070XV36B 7625842 14ACXS030-230A TXV 27,600 14.00 12.00 CH35-36B 7625822 14ACXS030-230A TXV 28,000 15.10 12.50 CH35-36C EL195UH090XE48C 7625846 14ACXS030-230A TXV 28,000 15.10 12.50 CH35-36C EL296UH090XE48C 7625848 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-36C EL296UH090XV36C 7625849 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-36C SLP98UH090XV36C 7625851 14ACXS030-230A TXV 27,800 14.25 12.00 CH35-36C 7625844 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-42B EL180UH070E36B 7625856 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-42B EL180UH070XE36B 7625858 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-42B EL180UH090E48B 7625860 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-42B EL180UH090XE48B 7625861 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-42B EL195UH045XE36B 7625863 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-42B EL195UH070XE36B 7625868 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-42B EL296UH045XE36B 7625870 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-42B EL296UH045XV36B 7625865 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 78 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-42B EL296UH070XE36B 7625867 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-42B EL296UH070XV36B 7625872 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-42B SL280UH090V36B 7625855 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-42B SLP98UH070XV36B 7625873 14ACXS030-230A TXV 28,000 14.50 12.50 CH35-42B 7625853 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-42C EL195UH090XE48C 7625877 14ACXS030-230A TXV 28,000 15.50 12.50 CH35-42C EL296UH090XE48C 7625879 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-42C EL296UH090XV36C 7625880 14ACXS030-230A TXV 28,000 16.00 13.00 CH35-42C SLP98UH090XV36C 7625882 14ACXS030-230A TXV 28,000 14.50 12.20 CH35-42C 7625875 14ACXS030-230A TXV 26,800 14.50 12.20 CR33-24A EL180DF045E36A 7625884 14ACXS030-230A TXV 26,800 14.25 12.20 CR33-24B EL180DF070E36B 7625889 14ACXS030-230A TXV 26,600 14.00 12.00 CR33-24B EL180DF090E48B 7783229 14ACXS030-230A TXV 26,600 14.25 12.20 CR33-24B EL296DF045XV36B 7783151 14ACXS030-230A TXV 26,600 14.00 12.00 CR33-24B EL296DF070XV48B 7625887 14ACXS030-230A TXV 26,600 14.25 12.20 CR33-24B SL280DF090V48B 7625885 14ACXS030-230A TXV 26,600 14.25 12.20 CR33-24B SLP98DF070XV36B 7628270 14ACXS030-230A TXV 28,000 15.10 12.50 CR33-30/36A EL180DF045E36A 7625896 14ACXS030-230A TXV 28,000 15.50 12.50 CR33-30/36A SL280DF070V36A 7625895 14ACXS030-230A TXV 28,000 14.25 12.00 CR33-30/36A 7625893 14ACXS030-230A TXV 28,000 15.50 12.50 CR33-30/36B EL180DF070E36B 7625904 14ACXS030-230A TXV 28,000 15.50 12.50 CR33-30/36B EL180DF090E48B 7625905 14ACXS030-230A TXV 28,000 15.10 12.50 CR33-30/36B EL195DF045XE36B 7625907 14ACXS030-230A TXV 28,000 15.50 12.50 CR33-30/36B EL195DF070XE48B 7625911 14ACXS030-230A TXV 28,000 15.10 12.50 CR33-30/36B EL296DF045XE36B 7625909 14ACXS030-230A TXV 28,000 15.50 12.50 CR33-30/36B EL296DF045XV36B 7625914 14ACXS030-230A TXV 28,000 15.50 12.50 CR33-30/36B EL296DF070XE48B 7625912 14ACXS030-230A TXV 28,000 15.10 12.50 CR33-30/36B EL296DF070XV48B 7625916 14ACXS030-230A TXV 28,000 15.50 12.50 CR33-30/36B SL280DF090V48B 7625902 14ACXS030-230A TXV 28,000 15.50 12.50 CR33-30/36B SLP98DF070XV36B 7625918 14ACXS030-230A TXV 28,000 14.25 12.00 CR33-30/36B 7625900 14ACXS030-230A TXV 28,000 16.00 13.00 CR33-30/36C SLP98DF090XV36C 7625923 14ACXS030-230A TXV 28,000 14.25 12.00 CR33-30/36C 7625921 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-25A EL180UH045E36A 7625930 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-25A EL180UH045XE36A 7625931 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-25A SL280UH070V36A 7625926 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-25A SL280UH070XV36A 7625928 14ACXS030-230A TXV 27,600 14.00 12.00 CX34-25A 7625925 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-25B EL180UH070E36B 7625940 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-25B EL180UH070XE36B 7625941 14ACXS030-230A TXV 27,800 15.50 12.50 CX34-25B EL180UH090E48B 7625935 14ACXS030-230A TXV 27,800 15.50 12.50 CX34-25B EL180UH090XE48B 7625936 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-25B EL195UH045XE36B 7625943 14ACXS030-230A TXV 28,000 15.00 12.50 CX34-25B EL195UH070XE36B 7625946 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-25B EL296UH045XE36B 7625944 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-25B EL296UH045XV36B 7625949 14ACXS030-230A TXV 28,000 15.00 12.50 CX34-25B EL296UH070XE36B 7625948 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-25B EL296UH070XV36B 7625951 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-25B SL280UH090V36B 7625938 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 79 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-25B SLP98UH070XV36B 7625953 14ACXS030-230A TXV 27,600 14.00 12.00 CX34-25B 7625933 14ACXS030-230A TXV 27,400 15.00 12.50 CX34-30A EL180UH045E36A 7782496 14ACXS030-230A TXV 27,400 15.00 12.50 CX34-30A EL180UH045XE36A 7625971 14ACXS030-230A TXV 27,400 15.00 12.50 CX34-30A SL280UH070V36A 7625965 14ACXS030-230A TXV 27,400 15.00 12.50 CX34-30A SL280UH070XV36A 7625968 14ACXS030-230A TXV 27,400 15.10 12.50 CX34-30B EL180UH070E36B 7782497 14ACXS030-230A TXV 27,400 15.10 12.50 CX34-30B EL180UH070XE36B 7625974 14ACXS030-230A TXV 27,200 15.10 12.50 CX34-30B EL180UH090E48B 7625954 14ACXS030-230A TXV 27,200 15.10 12.50 CX34-30B EL180UH090XE48B 7782495 14ACXS030-230A TXV 27,200 14.50 12.50 CX34-30B EL195UH045XE36B 7625957 14ACXS030-230A TXV 27,400 14.50 12.50 CX34-30B EL195UH070XE36B 7782498 14ACXS030-230A TXV 27,200 14.50 12.50 CX34-30B EL296UH045XE36B 7625960 14ACXS030-230A TXV 27,200 14.50 12.50 CX34-30B EL296UH045XV36B 7625963 14ACXS030-230A TXV 27,400 14.50 12.50 CX34-30B EL296UH070XE36B 7625977 14ACXS030-230A TXV 27,400 15.00 12.50 CX34-30B EL296UH070XV36B 7782499 14ACXS030-230A TXV 27,600 15.10 12.50 CX34-30B SL280UH090V36B 7782500 14ACXS030-230A TXV 27,400 15.00 12.50 CX34-30B SLP98UH070XV36B 7625980 14ACXS030-230A TXV 27,400 15.10 12.50 CX34-30C SLP98UH090XV36C 7628273 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-31A EL180UH045E36A 7782502 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-31A EL180UH045XE36A 7625989 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-31A SL280UH070V36A 7782501 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-31A SL280UH070XV36A 7625986 14ACXS030-230A TXV 28,000 14.25 12.20 CX34-31A 7625983 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-31B EL180UH070E36B 7782504 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-31B EL180UH070XE36B 7625995 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-31B EL180UH090E48B 7782505 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-31B EL180UH090XE48B 7625998 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-31B EL195UH045XE36B 7782506 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-31B EL195UH070XE36B 7782507 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-31B EL296UH045XE36B 7626001 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-31B EL296UH045XV36B 7782508 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-31B EL296UH070XE36B 7626004 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-31B EL296UH070XV36B 7626007 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-31B SL280UH090V36B 7625992 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-31B SLP98UH070XV36B 8083369 14ACXS030-230A TXV 28,000 14.25 12.20 CX34-31B 7782503 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-36A EL180UH045E36A 7782511 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-36A EL180UH045XE36A 7626016 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-36A SL280UH070V36A 7782510 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-36A SL280UH070XV36A 7626013 14ACXS030-230A TXV 27,600 14.00 12.00 CX34-36A 7626010 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-36B EL180UH070E36B 7626023 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-36B EL180UH070XE36B 7782514 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-36B EL180UH090E48B 7626026 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-36B EL180UH090XE48B 7782515 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-36B EL195UH045XE36B 7626029 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-36B EL195UH070XE36B 7626032 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-36B EL296UH045XE36B 7782516 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 80 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS030-230A TXV 27,800 15.10 12.50 CX34-36B EL296UH045XV36B 7626020 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-36B EL296UH070XE36B 7782517 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-36B EL296UH070XV36B 7626035 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-36B SL280UH090V36B 7782513 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-36B SLP98UH070XV36B 7782518 14ACXS030-230A TXV 27,600 14.00 12.00 CX34-36B 7782512 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-36C EL195UH090XE48C 7626038 14ACXS030-230A TXV 28,000 15.10 12.50 CX34-36C EL296UH090XE48C 7782519 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-36C EL296UH090XV36C 7626041 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-36C SLP98UH090XV36C 7782520 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-38A EL180UH045E36A 7782522 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-38A EL180UH045XE36A 7626050 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-38A SL280UH070V36A 7782521 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-38A SL280UH070XV36A 7626047 14ACXS030-230A TXV 28,000 14.50 12.20 CX34-38A 7626044 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-38B EL180UH070E36B 7782524 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-38B EL180UH070XE36B 7626056 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-38B EL180UH090E48B 7782525 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-38B EL180UH090XE48B 7626059 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-38B EL195UH045XE36B 7782526 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-38B EL195UH070XE36B 7782527 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-38B EL296UH045XE36B 7626062 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-38B EL296UH045XV36B 7782528 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-38B EL296UH070XE36B 7626065 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-38B EL296UH070XV36B 7626068 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-38B SL280UH090V36B 7626053 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-38B SLP98UH070XV36B 7782529 14ACXS030-230A TXV 28,000 14.50 12.20 CX34-38B 7782523 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-42 EL180UH070E36B 7783153 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-42 EL180UH070XE36B 7628279 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-42 EL180UH090E48B 7783154 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-42 EL180UH090XE48B 7628282 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-42 EL195UH045XE36B 7783155 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-42 EL195UH070XE36B 7783156 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-42 EL296UH045XE36B 7628285 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-42 EL296UH045XV36B 7783157 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-42 EL296UH070XE36B 7628288 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-42 EL296UH070XV36B 7628291 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-42 SL280UH090V36B 7628276 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-42 SLP98UH070XV36B 7783158 14ACXS030-230A TXV 27,600 14.00 12.00 CX34-42 7783152 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-43B EL180UH070E36B 7626074 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-43B EL180UH070XE36B 7782531 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-43B EL180UH090E48B 7626077 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-43B EL180UH090XE48B 7782532 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-43B EL195UH045XE36B 7626080 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-43B EL195UH070XE36B 7626083 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-43B EL296UH045XE36B 7782533 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-43B EL296UH045XV36B 7626086 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 81 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS030-230A TXV 28,000 15.50 12.50 CX34-43B EL296UH070XE36B 7782534 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-43B EL296UH070XV36B 7782535 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-43B SL280UH090V36B 7782530 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-43B SLP98UH070XV36B 7626089 14ACXS030-230A TXV 28,000 14.50 12.20 CX34-43B 7626071 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-43C EL195UH090XE48C 7626093 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-43C EL296UH090XE48C 7782537 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-43C EL296UH090XV36C 7626096 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-43C EL296UH090XV48C 7628294 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-43C SLP98UH090XV36C 7782538 14ACXS030-230A TXV 28,000 16.00 13.00 CX34-43C SLP98UH090XV48C 7783159 14ACXS030-230A TXV 28,000 14.50 12.20 CX34-43C 7782536 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-24A EL180UH045E36A 8259898 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-24A EL180UH045XE36A 8259893 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-24A SL280UH070V36A 8259895 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-24A SL280UH070XV36A 8259897 14ACXS030-230A TXV 27,600 14.00 12.00 CX35-24A 8259892 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-24B EL180UH070E36B 8259918 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-24B EL180UH070XE36B 8259920 14ACXS030-230A TXV 27,800 15.50 12.50 CX35-24B EL180UH090E48B 8259913 14ACXS030-230A TXV 27,800 15.50 12.50 CX35-24B EL180UH090XE48B 8259915 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-24B EL195UH045XE36B 8259903 14ACXS030-230A TXV 28,000 15.00 12.50 CX35-24B EL195UH070XE36B 8259907 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-24B EL296UH045XE36B 8259905 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-24B EL296UH045XV36B 8259910 14ACXS030-230A TXV 28,000 15.00 12.50 CX35-24B EL296UH070XE36B 8259908 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-24B EL296UH070XV36B 8259912 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-24B SL280UH090V36B 8259916 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-24B SLP98UH070XV36B 8259902 14ACXS030-230A TXV 27,600 14.00 12.00 CX35-24B 8259900 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-30/36A EL180UH045E36A 8259954 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-30/36A EL180UH045XE36A 8259958 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30/36A SL280UH070V36A 8259953 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30/36A SL280UH070XV36A 8259956 14ACXS030-230A TXV 27,600 14.00 12.00 CX35-30/36A 8259951 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30/36B EL180UH070E36B 8259977 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30/36B EL180UH070XE36B 8259961 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30/36B EL180UH090E48B 8259979 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30/36B EL180UH090XE48B 8259963 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-30/36B EL195UH045XE36B 8259971 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-30/36B EL195UH070XE36B 8259972 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-30/36B EL296UH045XE36B 8259964 14ACXS030-230A TXV 27,800 15.10 12.50 CX35-30/36B EL296UH045XV36B 8259976 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-30/36B EL296UH070XE36B 8259966 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30/36B EL296UH070XV36B 8259974 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30/36B SL280UH090V36B 8259969 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30/36B SLP98UH070XV36B 8259968 14ACXS030-230A TXV 27,600 14.00 12.00 CX35-30/36B 8259959 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-30/36C EL195UH090XE48C 8259984 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 82 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-30/36C EL296UH090XE48C 8259982 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30/36C EL296UH090XV36C 8259986 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30/36C SLP98UH090XV36C 8259981 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30A EL180UH045E36A 8259925 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30A EL180UH045XE36A 8259926 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-30A SL280UH070V36A 8259923 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-30A SL280UH070XV36A 8259928 14ACXS030-230A TXV 28,000 14.25 12.20 CX35-30A 8259921 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-30B EL180UH070E36B 8259938 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-30B EL180UH070XE36B 8259945 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-30B EL180UH090E48B 8259940 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-30B EL180UH090XE48B 8259946 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30B EL195UH045XE36B 8259933 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-30B EL195UH070XE36B 8259935 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30B EL296UH045XE36B 8259948 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-30B EL296UH045XV36B 8259936 14ACXS030-230A TXV 28,000 15.10 12.50 CX35-30B EL296UH070XE36B 8259949 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-30B EL296UH070XV36B 8259941 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-30B SL280UH090V36B 8259943 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-30B SLP98UH070XV36B 8259931 14ACXS030-230A TXV 28,000 14.25 12.20 CX35-30B 8259930 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-36A EL180UH045E36A 8259991 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-36A EL180UH045XE36A 8259992 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-36A SL280UH070V36A 8259989 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-36A SL280UH070XV36A 8259994 14ACXS030-230A TXV 28,000 14.50 12.20 CX35-36A 8259987 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-36B EL180UH070E36B 8260002 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-36B EL180UH070XE36B 8260011 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-36B EL180UH090E48B 8260004 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-36B EL180UH090XE48B 8260012 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-36B EL195UH045XE36B 8260006 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-36B EL195UH070XE36B 8259998 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-36B EL296UH045XE36B 8260014 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-36B EL296UH045XV36B 8259999 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-36B EL296UH070XE36B 8260016 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-36B EL296UH070XV36B 8260007 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-36B SL280UH090V36B 8260009 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-36B SLP98UH070XV36B 8260001 14ACXS030-230A TXV 28,000 14.50 12.20 CX35-36B 8259996 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-48B EL180UH070E36B 8260031 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-48B EL180UH070XE36B 8260026 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-48B EL180UH090E48B 8260032 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-48B EL180UH090XE48B 8260027 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-48B EL195UH045XE36B 8260034 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-48B EL195UH070XE36B 8260036 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-48B EL296UH045XE36B 8260019 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-48B EL296UH045XV36B 8260038 14ACXS030-230A TXV 28,000 15.50 12.50 CX35-48B EL296UH070XE36B 8260021 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-48B EL296UH070XV36B 8260022 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 83 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-48B SL280UH090V36B 8260024 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-48B SLP98UH070XV36B 8260029 14ACXS030-230A TXV 28,000 14.50 12.20 CX35-48B 8260017 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-48C EL195UH090XE48C 8260047 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-48C EL296UH090XE48C 8260043 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-48C EL296UH090XV36C 8260049 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-48C EL296UH090XV48C 8260046 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-48C SLP98UH090XV36C 8260044 14ACXS030-230A TXV 28,000 16.00 13.00 CX35-48C SLP98UH090XV48C 8260041 14ACXS030-230A TXV 28,000 14.50 12.20 CX35-48C 8260039 14ACXS036-230A RFC 33,600 14.00 12.00 C33-31A 7782539 14ACXS036-230A RFC 33,600 14.00 12.00 C33-31B 7782542 14ACXS036-230A RFC 34,000 14.00 12.00 C33-38A 7782567 14ACXS036-230A RFC 34,000 14.00 12.00 C33-38B 7782570 14ACXS036-230A RFC 34,000 14.25 12.20 C33-43 7628321 14ACXS036-230A RFC 33,600 14.00 12.00 C33-48 7783168 14ACXS036-230A RFC 34,400 14.25 12.20 C33-49 7628325 14ACXS036-230A RFC 34,000 14.25 12.20 C33-50/60C 7626315 14ACXS036-230A RFC 33,600 14.00 12.00 C35-30A 8471033 14ACXS036-230A RFC 33,600 14.00 12.00 C35-30B 8471036 14ACXS036-230A RFC 34,000 14.00 12.00 C35-36A 8471039 14ACXS036-230A RFC 34,000 14.00 12.00 C35-36B 8471042 14ACXS036-230A RFC 34,000 14.00 12.00 C35-48B 8471044 14ACXS036-230A RFC 34,000 14.00 12.00 C35-48C 8471046 14ACXS036-230A RFC 34,400 14.00 12.20 C35-49C 8471047 14ACXS036-230A RFC 34,000 14.00 12.20 C35-50/60C 8471049 14ACXS036-230A RFC 33,800 14.00 12.20 CH33-31B 7782648 14ACXS036-230A RFC 34,600 14.50 12.20 CH33-43B 7626526 14ACXS036-230A RFC 34,000 14.25 12.20 CH33-44/48B 7626578 14ACXS036-230A RFC 34,000 14.25 12.20 CH33-48 7628396 14ACXS036-230A RFC 34,600 14.50 12.20 CH33-49 7783186 14ACXS036-230A RFC 34,400 14.25 12.20 CH33-50/60C 7782716 14ACXS036-230A RFC 33,600 14.00 12.00 CR33-48B 7628438 14ACXS036-230A RFC 33,800 14.00 12.00 CR33-48C 7628456 14ACXS036-230A TXV 34,200 15.10 12.50 C33-31A EL180UH045E36A 7782541 14ACXS036-230A TXV 34,200 15.10 12.50 C33-31A EL180UH045XE36A 7626108 14ACXS036-230A TXV 34,400 15.10 12.50 C33-31A SL280UH070V36A 7782540 14ACXS036-230A TXV 34,400 15.10 12.50 C33-31A SL280UH070XV36A 7626105 14ACXS036-230A TXV 34,000 14.50 12.00 C33-31A 7626102 14ACXS036-230A TXV 34,400 15.00 12.50 C33-31B EL180UH070E36B 7782545 14ACXS036-230A TXV 34,400 15.00 12.50 C33-31B EL180UH070XE36B 7626119 14ACXS036-230A TXV 34,400 15.50 12.50 C33-31B EL180UH090E48B 7782546 14ACXS036-230A TXV 34,400 15.50 12.50 C33-31B EL180UH090XE48B 7626122 14ACXS036-230A TXV 34,000 14.50 12.20 C33-31B EL195UH045XE36B 7782547 14ACXS036-230A TXV 34,000 15.10 12.50 C33-31B EL195UH070XE36B 7782548 14ACXS036-230A TXV 34,000 14.50 12.20 C33-31B EL296UH045XE36B 7626125 14ACXS036-230A TXV 34,200 15.10 12.50 C33-31B EL296UH045XV36B 7782549 14ACXS036-230A TXV 34,000 15.10 12.50 C33-31B EL296UH070XE36B 7626128 14ACXS036-230A TXV 34,200 15.10 12.50 C33-31B EL296UH070XV36B 7626131 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 84 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 34,400 15.50 12.50 C33-31B SL280UH090V36B 7626113 14ACXS036-230A TXV 34,400 15.50 12.50 C33-31B SL280UH090V48B 7782544 14ACXS036-230A TXV 34,400 15.50 12.50 C33-31B SL280UH090XV48B 7626116 14ACXS036-230A TXV 34,200 15.10 12.50 C33-31B SLP98UH070XV36B 7782550 14ACXS036-230A TXV 34,000 14.50 12.00 C33-31B 7782543 14ACXS036-230A TXV 33,200 14.50 12.20 C33-36A EL180UH045E36A 7782552 14ACXS036-230A TXV 33,200 14.50 12.20 C33-36A EL180UH045XE36A 7626140 14ACXS036-230A TXV 33,400 15.00 12.20 C33-36A SL280UH070V36A 7782551 14ACXS036-230A TXV 33,400 15.00 12.20 C33-36A SL280UH070XV36A 7626137 14ACXS036-230A TXV 33,000 14.00 11.50 C33-36A 7626134 14ACXS036-230A TXV 33,400 15.50 12.50 C33-36B EL180UH070E36B 7782555 14ACXS036-230A TXV 33,400 15.50 12.50 C33-36B EL180UH070XE36B 7626149 14ACXS036-230A TXV 33,400 15.10 12.50 C33-36B EL180UH090E48B 7782556 14ACXS036-230A TXV 33,400 15.10 12.50 C33-36B EL180UH090XE48B 7626152 14ACXS036-230A TXV 33,000 15.00 12.50 C33-36B EL195UH045XE36B 7782557 14ACXS036-230A TXV 33,200 14.50 12.00 C33-36B EL195UH070XE36B 7782558 14ACXS036-230A TXV 33,000 15.00 12.50 C33-36B EL296UH045XE36B 7626155 14ACXS036-230A TXV 33,400 15.00 12.50 C33-36B EL296UH045XV36B 7782559 14ACXS036-230A TXV 33,200 14.50 12.00 C33-36B EL296UH070XE36B 7626158 14ACXS036-230A TXV 33,400 15.00 12.50 C33-36B EL296UH070XV36B 7626161 14ACXS036-230A TXV 33,600 15.50 12.50 C33-36B SL280UH090V36B 7626143 14ACXS036-230A TXV 33,600 15.50 12.50 C33-36B SL280UH090V48B 7782554 14ACXS036-230A TXV 33,600 15.50 12.50 C33-36B SL280UH090XV48B 7626146 14ACXS036-230A TXV 33,400 15.00 12.50 C33-36B SLP98UH070XV36B 7782560 14ACXS036-230A TXV 33,000 14.00 11.50 C33-36B 7782553 14ACXS036-230A TXV 33,600 15.10 12.50 C33-36C EL180UH090E60C 7782561 14ACXS036-230A TXV 33,400 15.50 12.50 C33-36C EL180UH110E60C 7626168 14ACXS036-230A TXV 33,400 15.50 12.50 C33-36C EL180UH110XE60C 7782562 14ACXS036-230A TXV 33,200 15.10 12.50 C33-36C EL195UH090XE48C 7626171 14ACXS036-230A TXV 33,600 15.10 12.50 C33-36C EL195UH110XE60C 7626174 14ACXS036-230A TXV 33,200 15.10 12.50 C33-36C EL296UH090XE48C 7782563 14ACXS036-230A TXV 33,600 15.50 12.50 C33-36C EL296UH090XV36C 7626177 14ACXS036-230A TXV 33,400 15.50 12.50 C33-36C EL296UH090XV48C 7626180 14ACXS036-230A TXV 33,600 15.10 12.50 C33-36C EL296UH110XE60C 7782564 14ACXS036-230A TXV 33,600 15.50 12.50 C33-36C EL296UH110XV48C 7626183 14ACXS036-230A TXV 33,600 15.50 12.50 C33-36C SLP98UH090XV36C 7782565 14ACXS036-230A TXV 33,400 15.50 12.50 C33-36C SLP98UH090XV48C 7782566 14ACXS036-230A TXV 33,800 15.50 12.50 C33-36C SLP98UH110XV60C 7628297 14ACXS036-230A TXV 33,000 14.00 11.50 C33-36C 7626165 14ACXS036-230A TXV 34,400 15.10 12.50 C33-38A EL180UH045E36A 7782569 14ACXS036-230A TXV 34,400 15.10 12.50 C33-38A EL180UH045XE36A 7626192 14ACXS036-230A TXV 34,600 15.50 12.50 C33-38A SL280UH070V36A 7782568 14ACXS036-230A TXV 34,600 15.50 12.50 C33-38A SL280UH070XV36A 7626189 14ACXS036-230A TXV 34,200 14.25 12.20 C33-38A 7626186 14ACXS036-230A TXV 34,600 16.00 13.00 C33-38B EL180UH070E36B 7782571 14ACXS036-230A TXV 34,600 16.00 13.00 C33-38B EL180UH070XE36B 7626207 14ACXS036-230A TXV 34,600 16.00 13.00 C33-38B EL180UH090E48B 7626209 14ACXS036-230A TXV 34,600 16.00 13.00 C33-38B EL180UH090XE48B 7782572 14ACXS036-230A TXV 34,400 15.00 12.50 C33-38B EL195UH045XE36B 7626212 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 85 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 34,400 15.00 12.50 C33-38B EL195UH070XE36B 7626216 14ACXS036-230A TXV 34,400 15.00 12.50 C33-38B EL296UH045XE36B 7782573 14ACXS036-230A TXV 34,600 15.50 12.50 C33-38B EL296UH045XV36B 7782574 14ACXS036-230A TXV 34,400 15.00 12.50 C33-38B EL296UH070XE36B 7626218 14ACXS036-230A TXV 34,600 15.50 12.50 C33-38B EL296UH070XV36B 7626221 14ACXS036-230A TXV 34,800 16.00 13.00 C33-38B SL280UH090V36B 7626199 14ACXS036-230A TXV 34,800 16.00 13.00 C33-38B SL280UH090V48B 7626202 14ACXS036-230A TXV 34,800 16.00 13.00 C33-38B SL280UH090XV48B 7626204 14ACXS036-230A TXV 34,600 15.50 12.50 C33-38B SLP98UH070XV36B 7782575 14ACXS036-230A TXV 34,200 14.25 12.20 C33-38B 7626196 14ACXS036-230A TXV 33,400 15.50 12.50 C33-42 EL180UH070E36B 7783162 14ACXS036-230A TXV 33,400 15.50 12.50 C33-42 EL180UH070XE36B 7628306 14ACXS036-230A TXV 33,400 15.10 12.50 C33-42 EL180UH090E48B 7783163 14ACXS036-230A TXV 33,400 15.10 12.50 C33-42 EL180UH090XE48B 7628309 14ACXS036-230A TXV 33,000 15.00 12.50 C33-42 EL195UH045XE36B 7783164 14ACXS036-230A TXV 33,200 14.50 12.00 C33-42 EL195UH070XE36B 7783165 14ACXS036-230A TXV 33,000 15.00 12.50 C33-42 EL296UH045XE36B 7628312 14ACXS036-230A TXV 33,400 15.00 12.50 C33-42 EL296UH045XV36B 7783166 14ACXS036-230A TXV 33,200 14.50 12.00 C33-42 EL296UH070XE36B 7628315 14ACXS036-230A TXV 33,400 15.00 12.50 C33-42 EL296UH070XV36B 7628318 14ACXS036-230A TXV 33,600 15.50 12.50 C33-42 SL280UH090V36B 7628300 14ACXS036-230A TXV 33,600 15.50 12.50 C33-42 SL280UH090V48B 7783161 14ACXS036-230A TXV 33,600 15.50 12.50 C33-42 SL280UH090XV48B 7628303 14ACXS036-230A TXV 33,400 15.00 12.50 C33-42 SLP98UH070XV36B 7783167 14ACXS036-230A TXV 33,000 14.00 11.50 C33-42 7783160 14ACXS036-230A TXV 34,800 16.00 13.00 C33-43B EL180UH070E36B 7626230 14ACXS036-230A TXV 34,800 16.00 13.00 C33-43B EL180UH070XE36B 7782578 14ACXS036-230A TXV 34,800 16.00 13.00 C33-43B EL180UH090E48B 7626233 14ACXS036-230A TXV 34,800 16.00 13.00 C33-43B EL180UH090XE48B 7782579 14ACXS036-230A TXV 34,400 15.00 12.50 C33-43B EL195UH045XE36B 7626236 14ACXS036-230A TXV 34,600 15.10 12.50 C33-43B EL195UH070XE36B 7626239 14ACXS036-230A TXV 34,400 15.00 12.50 C33-43B EL296UH045XE36B 7782580 14ACXS036-230A TXV 34,800 15.50 12.50 C33-43B EL296UH045XV36B 7626242 14ACXS036-230A TXV 34,600 15.10 12.50 C33-43B EL296UH070XE36B 7782581 14ACXS036-230A TXV 34,800 15.50 12.50 C33-43B EL296UH070XV36B 7782582 14ACXS036-230A TXV 34,800 16.00 13.00 C33-43B SL280UH090V36B 7782576 14ACXS036-230A TXV 35,000 16.00 13.00 C33-43B SL280UH090V48B 7626227 14ACXS036-230A TXV 35,000 16.00 13.00 C33-43B SL280UH090XV48B 7782577 14ACXS036-230A TXV 34,800 15.50 12.50 C33-43B SLP98UH070XV36B 7626245 14ACXS036-230A TXV 34,400 14.50 12.20 C33-43B 7626224 14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C EL180UH090E60C 7626254 14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C EL180UH110E60C 7782586 14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C EL180UH110XE60C 7626257 14ACXS036-230A TXV 34,600 15.50 12.50 C33-43C EL195UH090XE48C 7782587 14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C EL195UH110XE60C 7782588 14ACXS036-230A TXV 34,600 15.50 12.50 C33-43C EL296UH090XE48C 7626260 14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C EL296UH090XV36C 7782589 14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C EL296UH090XV48C 7782590 14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C EL296UH110XE60C 7626263 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 86 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 35,000 16.00 13.00 C33-43C EL296UH110XV48C 7782591 14ACXS036-230A TXV 35,200 16.00 13.00 C33-43C EL296UH110XV60C 7626273 14ACXS036-230A TXV 35,400 16.00 13.00 C33-43C SL280UH090V60C 7626248 14ACXS036-230A TXV 35,400 16.00 13.00 C33-43C SL280UH090XV60C 7782584 14ACXS036-230A TXV 35,200 16.00 13.00 C33-43C SL280UH110V60C 7626251 14ACXS036-230A TXV 35,200 16.00 13.00 C33-43C SL280UH110XV60C 7782585 14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C SLP98UH090XV36C 7626267 14ACXS036-230A TXV 34,800 16.00 13.00 C33-43C SLP98UH090XV48C 7626270 14ACXS036-230A TXV 35,200 16.00 13.00 C33-43C SLP98UH110XV60C 7782592 14ACXS036-230A TXV 34,400 14.50 12.20 C33-43C 7782583 14ACXS036-230A TXV 34,200 16.00 13.00 C33-48B EL180UH070E36B 7626283 14ACXS036-230A TXV 34,200 16.00 13.00 C33-48B EL180UH070XE36B 7782595 14ACXS036-230A TXV 34,200 15.50 12.50 C33-48B EL180UH090E48B 7626286 14ACXS036-230A TXV 34,200 15.50 12.50 C33-48B EL180UH090XE48B 7782596 14ACXS036-230A TXV 33,800 15.10 12.50 C33-48B EL195UH045XE36B 7626289 14ACXS036-230A TXV 34,200 15.00 12.50 C33-48B EL195UH070XE36B 7626292 14ACXS036-230A TXV 33,800 15.10 12.50 C33-48B EL296UH045XE36B 7782597 14ACXS036-230A TXV 34,200 15.10 12.50 C33-48B EL296UH045XV36B 7626296 14ACXS036-230A TXV 34,200 15.00 12.50 C33-48B EL296UH070XE36B 7782598 14ACXS036-230A TXV 34,200 15.10 12.50 C33-48B EL296UH070XV36B 7782599 14ACXS036-230A TXV 34,400 16.00 13.00 C33-48B SL280UH090V36B 7782593 14ACXS036-230A TXV 34,400 16.00 13.00 C33-48B SL280UH090V48B 7626280 14ACXS036-230A TXV 34,400 16.00 13.00 C33-48B SL280UH090XV48B 7782594 14ACXS036-230A TXV 34,000 15.10 12.50 C33-48B SLP98UH070XV36B 7626299 14ACXS036-230A TXV 33,800 14.50 12.00 C33-48B 7626276 14ACXS036-230A TXV 34,200 15.10 12.50 C33-48C EL195UH090XE48C 7626302 14ACXS036-230A TXV 34,400 15.50 12.50 C33-48C EL195UH110XE60C 7626305 14ACXS036-230A TXV 34,200 15.10 12.50 C33-48C EL296UH090XE48C 7782601 14ACXS036-230A TXV 34,400 15.50 12.50 C33-48C EL296UH090XV36C 7626309 14ACXS036-230A TXV 34,400 15.50 12.50 C33-48C EL296UH090XV48C 7626312 14ACXS036-230A TXV 34,400 15.50 12.50 C33-48C EL296UH110XE60C 7782602 14ACXS036-230A TXV 34,400 15.50 12.50 C33-48C SLP98UH090XV36C 7782603 14ACXS036-230A TXV 34,400 15.50 12.50 C33-48C SLP98UH090XV48C 7782604 14ACXS036-230A TXV 33,800 14.50 12.00 C33-48C 7782600 14ACXS036-230A TXV 35,200 16.00 13.00 C33-49 EL180UH090E60C 7628336 14ACXS036-230A TXV 35,000 16.00 13.00 C33-49 EL180UH110E60C 7783172 14ACXS036-230A TXV 35,000 16.00 13.00 C33-49 EL180UH110XE60C 7628341 14ACXS036-230A TXV 34,800 16.00 13.00 C33-49 EL195UH090XE48C 7783173 14ACXS036-230A TXV 35,200 16.00 13.00 C33-49 EL195UH110XE60C 7783174 14ACXS036-230A TXV 34,800 16.00 13.00 C33-49 EL296UH090XE48C 7628344 14ACXS036-230A TXV 35,200 16.00 13.00 C33-49 EL296UH090XV36C 7783175 14ACXS036-230A TXV 35,000 16.00 13.00 C33-49 EL296UH090XV48C 7783176 14ACXS036-230A TXV 35,200 16.00 13.00 C33-49 EL296UH110XE60C 7628347 14ACXS036-230A TXV 35,200 16.00 13.00 C33-49 EL296UH110XV48C 7783177 14ACXS036-230A TXV 35,600 16.00 13.00 C33-49 EL296UH110XV60C 7628356 14ACXS036-230A TXV 35,600 16.00 13.00 C33-49 SL280UH090V60C 7628328 14ACXS036-230A TXV 35,600 16.00 13.00 C33-49 SL280UH090XV60C 7783170 14ACXS036-230A TXV 35,400 16.00 13.00 C33-49 SL280UH110V60C 7628333 14ACXS036-230A TXV 35,400 16.00 13.00 C33-49 SL280UH110XV60C 7783171 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 87 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 35,200 16.00 13.00 C33-49 SLP98UH090XV36C 7628350 14ACXS036-230A TXV 35,000 16.00 13.00 C33-49 SLP98UH090XV48C 7628353 14ACXS036-230A TXV 35,600 16.00 13.00 C33-49 SLP98UH110XV60C 7783178 14ACXS036-230A TXV 34,600 14.50 12.20 C33-49 7783169 14ACXS036-230A TXV 34,800 16.00 13.00 C33-50/60C EL180UH090E60C 7626325 14ACXS036-230A TXV 34,800 16.00 13.00 C33-50/60C EL180UH110E60C 7782608 14ACXS036-230A TXV 34,800 16.00 13.00 C33-50/60C EL180UH110XE60C 7626328 14ACXS036-230A TXV 34,600 15.50 12.50 C33-50/60C EL195UH090XE48C 7782609 14ACXS036-230A TXV 34,800 16.00 13.00 C33-50/60C EL195UH110XE60C 7782610 14ACXS036-230A TXV 34,600 15.50 12.50 C33-50/60C EL296UH090XE48C 7626331 14ACXS036-230A TXV 34,800 16.00 13.00 C33-50/60C EL296UH090XV36C 7782611 14ACXS036-230A TXV 34,800 16.00 13.00 C33-50/60C EL296UH090XV48C 7782612 14ACXS036-230A TXV 34,800 16.00 13.00 C33-50/60C EL296UH110XE60C 7626334 14ACXS036-230A TXV 35,000 16.00 13.00 C33-50/60C EL296UH110XV48C 7782613 14ACXS036-230A TXV 35,200 16.00 13.00 C33-50/60C EL296UH110XV60C 7626344 14ACXS036-230A TXV 35,200 16.00 13.00 C33-50/60C SL280UH090V60C 7626318 14ACXS036-230A TXV 35,200 16.00 13.00 C33-50/60C SL280UH090XV60C 7782606 14ACXS036-230A TXV 35,000 16.00 13.00 C33-50/60C SL280UH110V60C 7626322 14ACXS036-230A TXV 35,000 16.00 13.00 C33-50/60C SL280UH110XV60C 7782607 14ACXS036-230A TXV 34,800 16.00 13.00 C33-50/60C SLP98UH090XV36C 7626338 14ACXS036-230A TXV 34,800 16.00 13.00 C33-50/60C SLP98UH090XV48C 7626341 14ACXS036-230A TXV 35,200 16.00 13.00 C33-50/60C SLP98UH110XV60C 7782614 14ACXS036-230A TXV 34,200 14.50 12.20 C33-50/60C 7782605 14ACXS036-230A TXV 33,200 14.50 12.20 C35-30/36A EL180UH045E36A 8258960 14ACXS036-230A TXV 33,200 14.50 12.20 C35-30/36A EL180UH045XE36A 8258964 14ACXS036-230A TXV 33,400 15.00 12.20 C35-30/36A SL280UH070V36A 8258959 14ACXS036-230A TXV 33,400 15.00 12.20 C35-30/36A SL280UH070XV36A 8258962 14ACXS036-230A TXV 33,000 14.00 11.50 C35-30/36A 8258957 14ACXS036-230A TXV 33,400 15.50 12.50 C35-30/36B EL180UH070E36B 8258970 14ACXS036-230A TXV 33,400 15.50 12.50 C35-30/36B EL180UH070XE36B 8258980 14ACXS036-230A TXV 33,400 15.10 12.50 C35-30/36B EL180UH090E48B 8258972 14ACXS036-230A TXV 33,400 15.10 12.50 C35-30/36B EL180UH090XE48B 8258982 14ACXS036-230A TXV 33,000 15.00 12.50 C35-30/36B EL195UH045XE36B 8258974 14ACXS036-230A TXV 33,200 14.50 12.00 C35-30/36B EL195UH070XE36B 8258975 14ACXS036-230A TXV 33,000 15.00 12.50 C35-30/36B EL296UH045XE36B 8258984 14ACXS036-230A TXV 33,400 15.00 12.50 C35-30/36B EL296UH045XV36B 8258977 14ACXS036-230A TXV 33,200 14.50 12.00 C35-30/36B EL296UH070XE36B 8258985 14ACXS036-230A TXV 33,400 15.00 12.50 C35-30/36B EL296UH070XV36B 8258987 14ACXS036-230A TXV 33,600 15.50 12.50 C35-30/36B SL280UH090V36B 8258989 14ACXS036-230A TXV 33,600 15.50 12.50 C35-30/36B SL280UH090V48B 8258969 14ACXS036-230A TXV 33,600 15.50 12.50 C35-30/36B SL280UH090XV48B 8258979 14ACXS036-230A TXV 33,400 15.00 12.50 C35-30/36B SLP98UH070XV36B 8258967 14ACXS036-230A TXV 33,000 14.00 11.50 C35-30/36B 8258966 14ACXS036-230A TXV 33,600 15.10 12.50 C35-30/36C EL180UH090E60C 8258994 14ACXS036-230A TXV 33,400 15.50 12.50 C35-30/36C EL180UH110E60C 8259004 14ACXS036-230A TXV 33,400 15.50 12.50 C35-30/36C EL180UH110XE60C 8258995 14ACXS036-230A TXV 33,200 15.10 12.50 C35-30/36C EL195UH090XE48C 8259005 14ACXS036-230A TXV 33,600 15.10 12.50 C35-30/36C EL195UH110XE60C 8259007 14ACXS036-230A TXV 33,200 15.10 12.50 C35-30/36C EL296UH090XE48C 8258997 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 88 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 33,600 15.50 12.50 C35-30/36C EL296UH090XV36C 8259008 14ACXS036-230A TXV 33,400 15.50 12.50 C35-30/36C EL296UH090XV48C 8259010 14ACXS036-230A TXV 33,600 15.10 12.50 C35-30/36C EL296UH110XE60C 8258999 14ACXS036-230A TXV 33,600 15.50 12.50 C35-30/36C EL296UH110XV48C 8259012 14ACXS036-230A TXV 33,600 15.50 12.50 C35-30/36C SLP98UH090XV36C 8259000 14ACXS036-230A TXV 33,400 15.50 12.50 C35-30/36C SLP98UH090XV48C 8258992 14ACXS036-230A TXV 33,800 15.50 12.50 C35-30/36C SLP98UH110XV60C 8259002 14ACXS036-230A TXV 33,000 14.00 11.50 C35-30/36C 8258990 14ACXS036-230A TXV 34,200 15.10 12.50 C35-30A EL180UH045E36A 8258930 14ACXS036-230A TXV 34,200 15.10 12.50 C35-30A EL180UH045XE36A 8258927 14ACXS036-230A TXV 34,400 15.10 12.50 C35-30A SL280UH070V36A 8258929 14ACXS036-230A TXV 34,400 15.10 12.50 C35-30A SL280UH070XV36A 8258926 14ACXS036-230A TXV 34,000 14.50 12.00 C35-30A 8258924 14ACXS036-230A TXV 34,400 15.00 12.50 C35-30B EL180UH070E36B 8258949 14ACXS036-230A TXV 34,400 15.00 12.50 C35-30B EL180UH070XE36B 8258937 14ACXS036-230A TXV 34,400 15.50 12.50 C35-30B EL180UH090E48B 8258950 14ACXS036-230A TXV 34,400 15.50 12.50 C35-30B EL180UH090XE48B 8258939 14ACXS036-230A TXV 34,000 14.50 12.20 C35-30B EL195UH045XE36B 8258940 14ACXS036-230A TXV 34,000 15.10 12.50 C35-30B EL195UH070XE36B 8258942 14ACXS036-230A TXV 34,000 14.50 12.20 C35-30B EL296UH045XE36B 8258952 14ACXS036-230A TXV 34,200 15.10 12.50 C35-30B EL296UH045XV36B 8258944 14ACXS036-230A TXV 34,000 15.10 12.50 C35-30B EL296UH070XE36B 8258954 14ACXS036-230A TXV 34,200 15.10 12.50 C35-30B EL296UH070XV36B 8258955 14ACXS036-230A TXV 34,400 15.50 12.50 C35-30B SL280UH090V36B 8258934 14ACXS036-230A TXV 34,400 15.50 12.50 C35-30B SL280UH090V48B 8258947 14ACXS036-230A TXV 34,400 15.50 12.50 C35-30B SL280UH090XV48B 8258935 14ACXS036-230A TXV 34,200 15.10 12.50 C35-30B SLP98UH070XV36B 8258945 14ACXS036-230A TXV 34,000 14.50 12.00 C35-30B 8258932 14ACXS036-230A TXV 34,400 15.10 12.50 C35-36A EL180UH045E36A 8260246 14ACXS036-230A TXV 34,400 15.10 12.50 C35-36A EL180UH045XE36A 8260249 14ACXS036-230A TXV 34,600 15.50 12.50 C35-36A SL280UH070V36A 8260244 14ACXS036-230A TXV 34,600 15.50 12.50 C35-36A SL280UH070XV36A 8260247 14ACXS036-230A TXV 34,200 14.25 12.20 C35-36A 8260243 14ACXS036-230A TXV 34,600 16.00 13.00 C35-36B EL180UH070E36B 8260256 14ACXS036-230A TXV 34,600 16.00 13.00 C35-36B EL180UH070XE36B 8260274 14ACXS036-230A TXV 34,600 16.00 13.00 C35-36B EL180UH090E48B 8260260 14ACXS036-230A TXV 34,600 16.00 13.00 C35-36B EL180UH090XE48B 8260258 14ACXS036-230A TXV 34,400 15.00 12.50 C35-36B EL195UH045XE36B 8260262 14ACXS036-230A TXV 34,400 15.00 12.50 C35-36B EL195UH070XE36B 8260264 14ACXS036-230A TXV 34,400 15.00 12.50 C35-36B EL296UH045XE36B 8260259 14ACXS036-230A TXV 34,600 15.50 12.50 C35-36B EL296UH045XV36B 8260253 14ACXS036-230A TXV 34,400 15.00 12.50 C35-36B EL296UH070XE36B 8260265 14ACXS036-230A TXV 34,600 15.50 12.50 C35-36B EL296UH070XV36B 8260267 14ACXS036-230A TXV 34,800 16.00 13.00 C35-36B SL280UH090V36B 8260269 14ACXS036-230A TXV 34,800 16.00 13.00 C35-36B SL280UH090V48B 8260271 14ACXS036-230A TXV 34,800 16.00 13.00 C35-36B SL280UH090XV48B 8260272 14ACXS036-230A TXV 34,600 15.50 12.50 C35-36B SLP98UH070XV36B 8260254 14ACXS036-230A TXV 34,200 14.25 12.20 C35-36B 8260251 14ACXS036-230A TXV 34,800 16.00 13.00 C35-48B EL180UH070E36B 8259029 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 89 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 34,800 16.00 13.00 C35-48B EL180UH070XE36B 8259026 14ACXS036-230A TXV 34,800 16.00 13.00 C35-48B EL180UH090E48B 8259031 14ACXS036-230A TXV 34,800 16.00 13.00 C35-48B EL180UH090XE48B 8259028 14ACXS036-230A TXV 34,400 15.00 12.50 C35-48B EL195UH045XE36B 8259033 14ACXS036-230A TXV 34,600 15.10 12.50 C35-48B EL195UH070XE36B 8259034 14ACXS036-230A TXV 34,400 15.00 12.50 C35-48B EL296UH045XE36B 8259018 14ACXS036-230A TXV 34,800 15.50 12.50 C35-48B EL296UH045XV36B 8259036 14ACXS036-230A TXV 34,600 15.10 12.50 C35-48B EL296UH070XE36B 8259020 14ACXS036-230A TXV 34,800 15.50 12.50 C35-48B EL296UH070XV36B 8259021 14ACXS036-230A TXV 34,800 16.00 13.00 C35-48B SL280UH090V36B 8259023 14ACXS036-230A TXV 35,000 16.00 13.00 C35-48B SL280UH090V48B 8259039 14ACXS036-230A TXV 35,000 16.00 13.00 C35-48B SL280UH090XV48B 8259024 14ACXS036-230A TXV 34,800 15.50 12.50 C35-48B SLP98UH070XV36B 8259038 14ACXS036-230A TXV 34,400 14.50 12.20 C35-48B 8259016 14ACXS036-230A TXV 34,800 16.00 13.00 C35-48C EL180UH090E60C 8259066 14ACXS036-230A TXV 34,800 16.00 13.00 C35-48C EL180UH110E60C 8259056 14ACXS036-230A TXV 34,800 16.00 13.00 C35-48C EL180UH110XE60C 8259067 14ACXS036-230A TXV 34,600 15.50 12.50 C35-48C EL195UH090XE48C 8259043 14ACXS036-230A TXV 34,800 16.00 13.00 C35-48C EL195UH110XE60C 8259044 14ACXS036-230A TXV 34,600 15.50 12.50 C35-48C EL296UH090XE48C 8259069 14ACXS036-230A TXV 34,800 16.00 13.00 C35-48C EL296UH090XV36C 8259046 14ACXS036-230A TXV 34,800 16.00 13.00 C35-48C EL296UH090XV48C 8259048 14ACXS036-230A TXV 34,600 16.00 13.00 C35-48C EL296UH110XE60C 8259071 14ACXS036-230A TXV 35,000 16.00 13.00 C35-48C EL296UH110XV48C 8259049 14ACXS036-230A TXV 35,200 16.00 13.00 C35-48C EL296UH110XV60C 8259061 14ACXS036-230A TXV 35,400 16.00 13.00 C35-48C SL280UH090V60C 8259062 14ACXS036-230A TXV 35,400 16.00 13.00 C35-48C SL280UH090XV60C 8259053 14ACXS036-230A TXV 35,200 16.00 13.00 C35-48C SL280UH110V60C 8259064 14ACXS036-230A TXV 35,200 16.00 13.00 C35-48C SL280UH110XV60C 8259054 14ACXS036-230A TXV 34,800 16.00 13.00 C35-48C SLP98UH090XV36C 8259057 14ACXS036-230A TXV 34,800 16.00 13.00 C35-48C SLP98UH090XV48C 8259059 14ACXS036-230A TXV 35,200 16.00 13.00 C35-48C SLP98UH110XV60C 8259051 14ACXS036-230A TXV 34,400 14.50 12.20 C35-48C 8259041 14ACXS036-230A TXV 35,200 16.00 13.00 C35-49C EL180UH090E60C 8259094 14ACXS036-230A TXV 35,000 16.00 13.00 C35-49C EL180UH110E60C 8259084 14ACXS036-230A TXV 35,000 16.00 13.00 C35-49C EL180UH110XE60C 8259096 14ACXS036-230A TXV 34,800 16.00 13.00 C35-49C EL195UH090XE48C 8259086 14ACXS036-230A TXV 35,200 16.00 13.00 C35-49C EL195UH110XE60C 8259087 14ACXS036-230A TXV 34,800 16.00 13.00 C35-49C EL296UH090XE48C 8259097 14ACXS036-230A TXV 35,200 16.00 13.00 C35-49C EL296UH090XV36C 8259074 14ACXS036-230A TXV 35,000 16.00 13.00 C35-49C EL296UH090XV48C 8259076 14ACXS036-230A TXV 35,200 16.00 13.00 C35-49C EL296UH110XE60C 8259099 14ACXS036-230A TXV 35,200 16.00 13.00 C35-49C EL296UH110XV48C 8259077 14ACXS036-230A TXV 35,600 16.00 13.00 C35-49C EL296UH110XV60C 8259091 14ACXS036-230A TXV 35,600 16.00 13.00 C35-49C SL280UH090V60C 8259102 14ACXS036-230A TXV 35,600 16.00 13.00 C35-49C SL280UH090XV60C 8259081 14ACXS036-230A TXV 35,400 16.00 13.00 C35-49C SL280UH110V60C 8259092 14ACXS036-230A TXV 35,400 16.00 13.00 C35-49C SL280UH110XV60C 8259082 14ACXS036-230A TXV 35,200 16.00 13.00 C35-49C SLP98UH090XV36C 8259101 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 90 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 35,000 16.00 13.00 C35-49C SLP98UH090XV48C 8259089 14ACXS036-230A TXV 35,600 16.00 13.00 C35-49C SLP98UH110XV60C 8259079 14ACXS036-230A TXV 34,600 14.50 12.20 C35-49C 8259072 14ACXS036-230A TXV 34,800 16.00 13.00 C35-50/60C EL180UH090E60C 8259132 14ACXS036-230A TXV 34,800 16.00 13.00 C35-50/60C EL180UH110E60C 8259111 14ACXS036-230A TXV 34,800 16.00 13.00 C35-50/60C EL180UH110XE60C 8259134 14ACXS036-230A TXV 34,600 15.50 12.50 C35-50/60C EL195UH090XE48C 8259113 14ACXS036-230A TXV 34,800 16.00 13.00 C35-50/60C EL195UH110XE60C 8259114 14ACXS036-230A TXV 34,600 15.50 12.50 C35-50/60C EL296UH090XE48C 8259121 14ACXS036-230A TXV 34,800 16.00 13.00 C35-50/60C EL296UH090XV36C 8259116 14ACXS036-230A TXV 34,800 16.00 13.00 C35-50/60C EL296UH090XV48C 8259118 14ACXS036-230A TXV 34,800 16.00 13.00 C35-50/60C EL296UH110XE60C 8259123 14ACXS036-230A TXV 35,000 16.00 13.00 C35-50/60C EL296UH110XV48C 8259106 14ACXS036-230A TXV 35,200 16.00 13.00 C35-50/60C EL296UH110XV60C 8259128 14ACXS036-230A TXV 35,200 16.00 13.00 C35-50/60C SL280UH090V60C 8259129 14ACXS036-230A TXV 35,200 16.00 13.00 C35-50/60C SL280UH090XV60C 8259119 14ACXS036-230A TXV 35,000 16.00 13.00 C35-50/60C SL280UH110V60C 8259131 14ACXS036-230A TXV 35,000 16.00 13.00 C35-50/60C SL280UH110XV60C 8259109 14ACXS036-230A TXV 34,800 16.00 13.00 C35-50/60C SLP98UH090XV36C 8259124 14ACXS036-230A TXV 34,800 16.00 13.00 C35-50/60C SLP98UH090XV48C 8259126 14ACXS036-230A TXV 35,200 16.00 13.00 C35-50/60C SLP98UH110XV60C 8259108 14ACXS036-230A TXV 34,200 14.50 12.20 C35-50/60C 8259104 14ACXS036-230A TXV 34,600 16.00 13.00 CBA27UHE-036 10259480 14ACXS036-230A TXV 35,600 16.00 13.00 CBA27UHE-042 10259392 14ACXS036-230A TXV 34,200 14.50 12.20 CBX25UH-036 7626347 14ACXS036-230A TXV 34,600 15.00 12.50 CBX25UH-042 7782615 14ACXS036-230A TXV 34,400 15.00 12.50 CBX25UHV-036 7626350 14ACXS036-230A TXV 35,200 16.00 13.00 CBX25UHV-042 7782616 14ACXS036-230A TXV 34,200 16.00 13.00 CBX27UH-036 7626354 14ACXS036-230A TXV 35,200 16.00 13.00 CBX27UH-042 7782617 14ACXS036-230A TXV 33,400 14.50 12.20 CBX32M-030 7626357 14ACXS036-230A TXV 33,800 14.50 12.20 CBX32M-036 7782618 14ACXS036-230A TXV 33,800 14.50 12.20 CBX32M-042 7626360 14ACXS036-230A TXV 34,800 15.10 12.50 CBX32M-048 7782619 14ACXS036-230A TXV 34,000 15.10 12.50 CBX32MV-036 7626363 14ACXS036-230A TXV 35,200 16.00 13.00 CBX32MV-048 7782620 14ACXS036-230A TXV 34,200 15.10 12.50 CBX40UHV-036 7626366 14ACXS036-230A TXV 35,000 15.50 12.50 CBX40UHV-042 7782621 14ACXS036-230A TXV 35,000 16.00 13.00 CBX40UHV-048 7626369 14ACXS036-230A TXV 33,600 15.00 12.50 CH23-41 EL180UH045E36A 7782623 14ACXS036-230A TXV 33,600 15.00 12.50 CH23-41 EL180UH045XE36A 7626375 14ACXS036-230A TXV 33,800 15.50 12.50 CH23-41 EL180UH070E36B 7782624 14ACXS036-230A TXV 33,800 15.50 12.50 CH23-41 EL180UH070XE36B 7626378 14ACXS036-230A TXV 33,800 15.50 12.50 CH23-41 EL180UH090E48B 7782625 14ACXS036-230A TXV 33,800 15.50 12.50 CH23-41 EL180UH090XE48B 7626381 14ACXS036-230A TXV 33,600 15.10 12.50 CH23-41 EL195UH045XE36B 7782626 14ACXS036-230A TXV 33,800 15.10 12.50 CH23-41 EL195UH070XE36B 7782627 14ACXS036-230A TXV 33,600 15.10 12.50 CH23-41 EL296UH045XE36B 7626384 14ACXS036-230A TXV 33,800 15.10 12.50 CH23-41 EL296UH045XV36B 7782628 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 91 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 33,800 15.10 12.50 CH23-41 EL296UH070XE36B 7626387 14ACXS036-230A TXV 33,800 15.10 12.50 CH23-41 EL296UH070XV36B 7626390 14ACXS036-230A TXV 34,000 16.00 13.00 CH23-41 SL280UH090V48B 7782622 14ACXS036-230A TXV 34,000 16.00 13.00 CH23-41 SL280UH090XV48B 7626372 14ACXS036-230A TXV 33,800 15.10 12.50 CH23-41 SLP98UH070XV36B 7782629 14ACXS036-230A TXV 33,600 15.00 12.50 CH23-51 EL180UH045E36A 7626399 14ACXS036-230A TXV 33,600 15.00 12.50 CH23-51 EL180UH045XE36A 7782632 14ACXS036-230A TXV 33,800 15.50 12.50 CH23-51 EL180UH070E36B 7626402 14ACXS036-230A TXV 33,800 15.50 12.50 CH23-51 EL180UH070XE36B 7782633 14ACXS036-230A TXV 33,800 15.50 12.50 CH23-51 EL180UH090E48B 7626405 14ACXS036-230A TXV 34,000 15.50 12.50 CH23-51 EL180UH090E60C 7782639 14ACXS036-230A TXV 33,800 15.50 12.50 CH23-51 EL180UH090XE48B 7782634 14ACXS036-230A TXV 34,000 15.50 12.50 CH23-51 EL180UH110E60C 7626423 14ACXS036-230A TXV 34,000 15.50 12.50 CH23-51 EL180UH110XE60C 7782640 14ACXS036-230A TXV 33,600 15.10 12.50 CH23-51 EL195UH045XE36B 7626408 14ACXS036-230A TXV 33,800 15.10 12.50 CH23-51 EL195UH070XE36B 7626411 14ACXS036-230A TXV 33,600 15.10 12.50 CH23-51 EL195UH090XE48C 7626426 14ACXS036-230A TXV 34,000 15.50 12.50 CH23-51 EL195UH110XE60C 7626429 14ACXS036-230A TXV 33,600 15.10 12.50 CH23-51 EL296UH045XE36B 7782635 14ACXS036-230A TXV 34,000 15.10 12.50 CH23-51 EL296UH045XV36B 7626414 14ACXS036-230A TXV 33,800 15.10 12.50 CH23-51 EL296UH070XE36B 7782636 14ACXS036-230A TXV 34,000 15.10 12.50 CH23-51 EL296UH070XV36B 7782637 14ACXS036-230A TXV 33,600 15.10 12.50 CH23-51 EL296UH090XE48C 7782641 14ACXS036-230A TXV 34,000 15.50 12.50 CH23-51 EL296UH090XV36C 7626432 14ACXS036-230A TXV 33,800 15.50 12.50 CH23-51 EL296UH090XV48C 7626435 14ACXS036-230A TXV 34,000 15.50 12.50 CH23-51 EL296UH110XE60C 7782642 14ACXS036-230A TXV 34,000 15.50 12.50 CH23-51 EL296UH110XV48C 7626438 14ACXS036-230A TXV 34,200 15.50 12.50 CH23-51 EL296UH110XV60C 7782645 14ACXS036-230A TXV 34,000 16.00 13.00 CH23-51 SL280UH090V36B 7782630 14ACXS036-230A TXV 34,200 16.00 13.00 CH23-51 SL280UH090V48B 7626396 14ACXS036-230A TXV 34,400 15.50 12.50 CH23-51 SL280UH090V60C 7628359 14ACXS036-230A TXV 34,200 16.00 13.00 CH23-51 SL280UH090XV48B 7782631 14ACXS036-230A TXV 34,400 15.50 12.50 CH23-51 SL280UH090XV60C 7783179 14ACXS036-230A TXV 34,200 15.50 12.50 CH23-51 SL280UH110V60C 7782638 14ACXS036-230A TXV 34,200 15.50 12.50 CH23-51 SL280UH110XV60C 7626420 14ACXS036-230A TXV 34,000 15.10 12.50 CH23-51 SLP98UH070XV36B 7626417 14ACXS036-230A TXV 34,000 15.50 12.50 CH23-51 SLP98UH090XV36C 7782643 14ACXS036-230A TXV 33,800 15.50 12.50 CH23-51 SLP98UH090XV48C 7782644 14ACXS036-230A TXV 34,200 15.50 12.50 CH23-51 SLP98UH110XV60C 7626441 14ACXS036-230A TXV 33,400 14.25 11.50 CH23-51 7626393 14ACXS036-230A TXV 34,000 15.00 12.50 CH33-31A EL180UH045E36A 7782647 14ACXS036-230A TXV 34,000 15.00 12.50 CH33-31A EL180UH045XE36A 7626447 14ACXS036-230A TXV 34,200 15.10 12.50 CH33-31A SL280UH070V36A 7782646 14ACXS036-230A TXV 34,200 15.10 12.50 CH33-31A SL280UH070XV36A 7626444 14ACXS036-230A TXV 34,600 15.10 12.50 CH33-31B EL180UH070E36B 7626457 14ACXS036-230A TXV 34,600 15.10 12.50 CH33-31B EL180UH070XE36B 7782651 14ACXS036-230A TXV 34,600 15.50 12.50 CH33-31B EL180UH090E48B 7626460 14ACXS036-230A TXV 34,600 15.50 12.50 CH33-31B EL180UH090XE48B 7782652 14ACXS036-230A TXV 34,200 14.50 12.20 CH33-31B EL195UH045XE36B 7626463 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 92 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 34,400 15.00 12.50 CH33-31B EL195UH070XE36B 7626466 14ACXS036-230A TXV 34,200 14.50 12.20 CH33-31B EL296UH045XE36B 7782653 14ACXS036-230A TXV 34,600 15.10 12.50 CH33-31B EL296UH045XV36B 7626469 14ACXS036-230A TXV 34,400 15.00 12.50 CH33-31B EL296UH070XE36B 7782654 14ACXS036-230A TXV 34,600 15.10 12.50 CH33-31B EL296UH070XV36B 7782655 14ACXS036-230A TXV 34,800 16.00 13.00 CH33-31B SL280UH090V36B 7782649 14ACXS036-230A TXV 34,800 15.50 12.50 CH33-31B SL280UH090V48B 7626454 14ACXS036-230A TXV 34,800 15.50 12.50 CH33-31B SL280UH090XV48B 7782650 14ACXS036-230A TXV 34,600 15.10 12.50 CH33-31B SLP98UH070XV36B 7626472 14ACXS036-230A TXV 34,200 14.50 12.20 CH33-31B 7626451 14ACXS036-230A TXV 33,000 14.50 12.20 CH33-36A EL180UH045E36A 7782657 14ACXS036-230A TXV 33,000 14.50 12.20 CH33-36A EL180UH045XE36A 7626478 14ACXS036-230A TXV 33,200 14.50 12.20 CH33-36A SL280UH070V36A 7782656 14ACXS036-230A TXV 33,200 14.50 12.20 CH33-36A SL280UH070XV36A 7626475 14ACXS036-230A TXV 33,400 15.50 12.50 CH33-36B EL180UH070E36B 7782660 14ACXS036-230A TXV 33,400 15.50 12.50 CH33-36B EL180UH070XE36B 7626487 14ACXS036-230A TXV 33,400 15.10 12.50 CH33-36B EL180UH090E48B 7782661 14ACXS036-230A TXV 33,400 15.10 12.50 CH33-36B EL180UH090XE48B 7626490 14ACXS036-230A TXV 33,000 15.00 12.50 CH33-36B EL195UH045XE36B 7782662 14ACXS036-230A TXV 33,200 15.00 12.50 CH33-36B EL195UH070XE36B 7782663 14ACXS036-230A TXV 33,000 15.00 12.50 CH33-36B EL296UH045XE36B 7626493 14ACXS036-230A TXV 33,400 14.50 12.20 CH33-36B EL296UH045XV36B 7628362 14ACXS036-230A TXV 33,200 15.00 12.50 CH33-36B EL296UH070XE36B 7626496 14ACXS036-230A TXV 33,400 15.00 12.50 CH33-36B EL296UH070XV36B 7782664 14ACXS036-230A TXV 33,400 15.50 12.50 CH33-36B SL280UH090V36B 7626481 14ACXS036-230A TXV 33,600 15.50 12.50 CH33-36B SL280UH090V48B 7782659 14ACXS036-230A TXV 33,600 15.50 12.50 CH33-36B SL280UH090XV48B 7626484 14ACXS036-230A TXV 33,400 15.00 12.50 CH33-36B SLP98UH070XV36B 7626499 14ACXS036-230A TXV 33,000 14.00 11.50 CH33-36B 7782658 14ACXS036-230A TXV 33,800 15.50 12.50 CH33-36C EL180UH090E60C 7626505 14ACXS036-230A TXV 33,800 15.50 12.50 CH33-36C EL180UH110E60C 7782667 14ACXS036-230A TXV 33,800 15.50 12.50 CH33-36C EL180UH110XE60C 7626508 14ACXS036-230A TXV 33,600 15.10 12.50 CH33-36C EL195UH090XE48C 7782668 14ACXS036-230A TXV 34,000 15.50 12.50 CH33-36C EL195UH110XE60C 7782669 14ACXS036-230A TXV 33,600 15.10 12.50 CH33-36C EL296UH090XE48C 7626511 14ACXS036-230A TXV 34,000 15.50 12.50 CH33-36C EL296UH090XV36C 7782670 14ACXS036-230A TXV 33,800 15.50 12.50 CH33-36C EL296UH090XV48C 7782671 14ACXS036-230A TXV 34,000 15.50 12.50 CH33-36C EL296UH110XE60C 7626514 14ACXS036-230A TXV 34,000 15.50 12.50 CH33-36C EL296UH110XV48C 7782672 14ACXS036-230A TXV 34,200 15.50 12.50 CH33-36C EL296UH110XV60C 7626523 14ACXS036-230A TXV 34,400 15.50 12.50 CH33-36C SL280UH090V60C 7783180 14ACXS036-230A TXV 34,400 15.50 12.50 CH33-36C SL280UH090XV60C 7628365 14ACXS036-230A TXV 34,200 15.50 12.50 CH33-36C SL280UH110V60C 7626502 14ACXS036-230A TXV 34,200 15.50 12.50 CH33-36C SL280UH110XV60C 7782666 14ACXS036-230A TXV 34,000 15.50 12.50 CH33-36C SLP98UH090XV36C 7626517 14ACXS036-230A TXV 33,800 15.50 12.50 CH33-36C SLP98UH090XV48C 7626520 14ACXS036-230A TXV 34,200 15.50 12.50 CH33-36C SLP98UH110XV60C 7782673 14ACXS036-230A TXV 33,400 14.25 11.50 CH33-36C 7782665 14ACXS036-230A TXV 34,200 15.00 12.50 CH33-42B EL180UH070E36B 7628372 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 93 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 34,200 15.00 12.50 CH33-42B EL180UH070XE36B 7628375 14ACXS036-230A TXV 34,200 15.50 12.50 CH33-42B EL180UH090E48B 7628377 14ACXS036-230A TXV 34,200 15.50 12.50 CH33-42B EL180UH090XE48B 7628380 14ACXS036-230A TXV 34,000 14.50 12.20 CH33-42B EL195UH045XE36B 7628383 14ACXS036-230A TXV 34,000 15.10 12.50 CH33-42B EL195UH070XE36B 7628388 14ACXS036-230A TXV 34,000 14.50 12.20 CH33-42B EL296UH045XE36B 7628385 14ACXS036-230A TXV 34,200 15.00 12.50 CH33-42B EL296UH045XV36B 7783184 14ACXS036-230A TXV 34,000 15.10 12.50 CH33-42B EL296UH070XE36B 7628390 14ACXS036-230A TXV 34,200 15.10 12.50 CH33-42B EL296UH070XV36B 7628393 14ACXS036-230A TXV 34,400 15.50 12.50 CH33-42B SL280UH090V36B 7783182 14ACXS036-230A TXV 34,400 15.50 12.50 CH33-42B SL280UH090V48B 7628368 14ACXS036-230A TXV 34,400 15.50 12.50 CH33-42B SL280UH090XV48B 7783183 14ACXS036-230A TXV 34,200 15.10 12.50 CH33-42B SLP98UH070XV36B 7783185 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-43B EL180UH070E36B 7782676 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-43B EL180UH070XE36B 7626536 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-43B EL180UH090E48B 7782677 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-43B EL180UH090XE48B 7626539 14ACXS036-230A TXV 35,000 15.10 12.50 CH33-43B EL195UH045XE36B 7782678 14ACXS036-230A TXV 35,000 15.10 12.50 CH33-43B EL195UH070XE36B 7782679 14ACXS036-230A TXV 35,000 15.10 12.50 CH33-43B EL296UH045XE36B 7626542 14ACXS036-230A TXV 35,400 15.50 12.50 CH33-43B EL296UH045XV36B 7782680 14ACXS036-230A TXV 35,000 15.10 12.50 CH33-43B EL296UH070XE36B 7626545 14ACXS036-230A TXV 35,400 15.50 12.50 CH33-43B EL296UH070XV36B 7626548 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-43B SL280UH090V36B 7626530 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-43B SL280UH090V48B 7782675 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-43B SL280UH090XV48B 7626533 14ACXS036-230A TXV 35,400 15.50 12.50 CH33-43B SLP98UH070XV36B 7782681 14ACXS036-230A TXV 35,000 14.50 12.20 CH33-43B 7782674 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-43C EL180UH090E60C 7626557 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-43C EL180UH110E60C 7782684 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-43C EL180UH110XE60C 7626560 14ACXS036-230A TXV 34,800 16.00 13.00 CH33-43C EL195UH090XE48C 7782685 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-43C EL195UH110XE60C 7782686 14ACXS036-230A TXV 34,800 16.00 13.00 CH33-43C EL296UH090XE48C 7626563 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-43C EL296UH090XV36C 7782687 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-43C EL296UH090XV48C 7782688 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-43C EL296UH110XE60C 7626566 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-43C EL296UH110XV48C 7782689 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-43C EL296UH110XV60C 7626575 14ACXS036-230A TXV 35,600 16.00 13.00 CH33-43C SL280UH090V60C 7626551 14ACXS036-230A TXV 35,600 16.00 13.00 CH33-43C SL280UH090XV60C 7782682 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-43C SL280UH110V60C 7626554 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-43C SL280UH110XV60C 7782683 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-43C SLP98UH090XV36C 7626569 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-43C SLP98UH090XV48C 7626572 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-43C SLP98UH110XV60C 7782690 14ACXS036-230A TXV 34,600 15.10 12.50 CH33-44/48B EL180UH070E36B 7782692 14ACXS036-230A TXV 34,600 15.10 12.50 CH33-44/48B EL180UH070XE36B 7626588 14ACXS036-230A TXV 34,600 15.50 12.50 CH33-44/48B EL180UH090E48B 7782693 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 94 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 34,600 15.50 12.50 CH33-44/48B EL180UH090XE48B 7626591 14ACXS036-230A TXV 34,400 14.50 12.20 CH33-44/48B EL195UH045XE36B 7782694 14ACXS036-230A TXV 34,400 15.00 12.50 CH33-44/48B EL195UH070XE36B 7782695 14ACXS036-230A TXV 34,400 14.50 12.20 CH33-44/48B EL296UH045XE36B 7626594 14ACXS036-230A TXV 34,600 15.10 12.50 CH33-44/48B EL296UH045XV36B 7782696 14ACXS036-230A TXV 34,400 15.00 12.50 CH33-44/48B EL296UH070XE36B 7626597 14ACXS036-230A TXV 34,600 15.10 12.50 CH33-44/48B EL296UH070XV36B 7626600 14ACXS036-230A TXV 34,800 16.00 13.00 CH33-44/48B SL280UH090V36B 7626581 14ACXS036-230A TXV 34,800 15.50 12.50 CH33-44/48B SL280UH090V48B 7626584 14ACXS036-230A TXV 34,800 15.50 12.50 CH33-44/48B SL280UH090XV48B 7626585 14ACXS036-230A TXV 34,600 15.10 12.50 CH33-44/48B SLP98UH070XV36B 7782697 14ACXS036-230A TXV 34,200 14.50 12.20 CH33-44/48B 7782691 14ACXS036-230A TXV 34,800 16.00 13.00 CH33-48C EL180UH090E60C 7782700 14ACXS036-230A TXV 34,800 16.00 13.00 CH33-48C EL180UH110E60C 7626613 14ACXS036-230A TXV 34,800 16.00 13.00 CH33-48C EL180UH110XE60C 7782701 14ACXS036-230A TXV 34,600 15.50 12.50 CH33-48C EL195UH090XE48C 7626616 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-48C EL195UH110XE60C 7626619 14ACXS036-230A TXV 34,600 15.50 12.50 CH33-48C EL296UH090XE48C 7782702 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-48C EL296UH090XV36C 7626622 14ACXS036-230A TXV 34,800 16.00 13.00 CH33-48C EL296UH090XV48C 7626625 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-48C EL296UH110XE60C 7782703 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-48C EL296UH110XV48C 7626628 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-48C EL296UH110XV60C 7782706 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-48C SL280UH090V60C 7782698 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-48C SL280UH090XV60C 7626607 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-48C SL280UH110V60C 7782699 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-48C SL280UH110XV60C 7626610 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-48C SLP98UH090XV36C 7782704 14ACXS036-230A TXV 34,800 16.00 13.00 CH33-48C SLP98UH090XV48C 7782705 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-48C SLP98UH110XV60C 7626631 14ACXS036-230A TXV 34,400 14.50 12.20 CH33-48C 7626604 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-49 EL180UH090E60C 7783189 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-49 EL180UH110E60C 7628408 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-49 EL180UH110XE60C 7783190 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-49 EL195UH090XE48C 7628411 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-49 EL195UH110XE60C 7628415 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-49 EL296UH090XE48C 7783191 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-49 EL296UH090XV36C 7783192 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-49 EL296UH090XV48C 7628423 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-49 EL296UH110XE60C 7628418 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-49 EL296UH110XV48C 7628429 14ACXS036-230A TXV 35,800 16.00 13.00 CH33-49 EL296UH110XV60C 7628430 14ACXS036-230A TXV 35,800 16.00 13.00 CH33-49 SL280UH090V60C 7783187 14ACXS036-230A TXV 35,800 16.00 13.00 CH33-49 SL280UH090XV60C 7628402 14ACXS036-230A TXV 35,600 16.00 13.00 CH33-49 SL280UH110V60C 7783188 14ACXS036-230A TXV 35,600 16.00 13.00 CH33-49 SL280UH110XV60C 7628405 14ACXS036-230A TXV 35,400 16.00 13.00 CH33-49 SLP98UH090XV36C 7628421 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-49 SLP98UH090XV48C 7628426 14ACXS036-230A TXV 35,800 16.00 13.00 CH33-49 SLP98UH110XV60C 7783193 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 95 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 34,800 14.50 12.20 CH33-49 7628399 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-50/60C EL180UH090E60C 7782709 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-50/60C EL180UH110E60C 7626640 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-50/60C EL180UH110XE60C 7782710 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-50/60C EL195UH090XE48C 7626643 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-50/60C EL195UH110XE60C 7626646 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-50/60C EL296UH090XE48C 7782711 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-50/60C EL296UH090XV36C 7626649 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-50/60C EL296UH090XV48C 7626652 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-50/60C EL296UH110XE60C 7782712 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-50/60C EL296UH110XV48C 7626655 14ACXS036-230A TXV 35,600 16.00 13.00 CH33-50/60C EL296UH110XV60C 7782715 14ACXS036-230A TXV 35,600 16.00 13.00 CH33-50/60C SL280UH090V60C 7782707 14ACXS036-230A TXV 35,600 16.00 13.00 CH33-50/60C SL280UH090XV60C 7626634 14ACXS036-230A TXV 35,600 16.00 13.00 CH33-50/60C SL280UH110V60C 7782708 14ACXS036-230A TXV 35,600 16.00 13.00 CH33-50/60C SL280UH110XV60C 7626637 14ACXS036-230A TXV 35,200 16.00 13.00 CH33-50/60C SLP98UH090XV36C 7782713 14ACXS036-230A TXV 35,000 16.00 13.00 CH33-50/60C SLP98UH090XV48C 7782714 14ACXS036-230A TXV 35,600 16.00 13.00 CH33-50/60C SLP98UH110XV60C 7626658 14ACXS036-230A TXV 34,600 14.50 12.20 CH33-50/60C 7626661 14ACXS036-230A TXV 34,000 15.00 12.50 CH35-30A EL180UH045E36A 7782718 14ACXS036-230A TXV 34,000 15.00 12.50 CH35-30A EL180UH045XE36A 7626667 14ACXS036-230A TXV 34,200 15.10 12.50 CH35-30A SL280UH070V36A 7782717 14ACXS036-230A TXV 34,200 15.10 12.50 CH35-30A SL280UH070XV36A 7626664 14ACXS036-230A TXV 34,800 15.10 12.50 CH35-30B EL180UH070E36B 7782721 14ACXS036-230A TXV 34,800 15.10 12.50 CH35-30B EL180UH070XE36B 7626676 14ACXS036-230A TXV 34,800 16.00 13.00 CH35-30B EL180UH090E48B 7782722 14ACXS036-230A TXV 34,800 16.00 13.00 CH35-30B EL180UH090XE48B 7626679 14ACXS036-230A TXV 34,400 14.50 12.20 CH35-30B EL195UH045XE36B 7782723 14ACXS036-230A TXV 34,400 15.00 12.50 CH35-30B EL195UH070XE36B 7782724 14ACXS036-230A TXV 34,400 14.50 12.20 CH35-30B EL296UH045XE36B 7626682 14ACXS036-230A TXV 34,600 15.10 12.50 CH35-30B EL296UH045XV36B 7782725 14ACXS036-230A TXV 34,400 15.00 12.50 CH35-30B EL296UH070XE36B 7626685 14ACXS036-230A TXV 34,600 15.10 12.50 CH35-30B EL296UH070XV36B 7626688 14ACXS036-230A TXV 34,800 16.00 13.00 CH35-30B SL280UH090V36B 7626670 14ACXS036-230A TXV 34,800 15.50 12.50 CH35-30B SL280UH090V48B 7782720 14ACXS036-230A TXV 34,800 15.50 12.50 CH35-30B SL280UH090XV48B 7626673 14ACXS036-230A TXV 34,600 15.10 12.50 CH35-30B SLP98UH070XV36B 7782726 14ACXS036-230A TXV 34,200 14.50 12.20 CH35-30B 7782719 14ACXS036-230A TXV 33,000 14.50 12.20 CH35-36A EL180UH045E36A 7626694 14ACXS036-230A TXV 33,000 14.50 12.20 CH35-36A EL180UH045XE36A 7782728 14ACXS036-230A TXV 33,200 14.50 12.20 CH35-36A SL280UH070V36A 7626691 14ACXS036-230A TXV 33,200 14.50 12.20 CH35-36A SL280UH070XV36A 7782727 14ACXS036-230A TXV 33,400 15.50 12.50 CH35-36B EL180UH070E36B 7626704 14ACXS036-230A TXV 33,400 15.50 12.50 CH35-36B EL180UH070XE36B 7782731 14ACXS036-230A TXV 33,400 15.10 12.50 CH35-36B EL180UH090E48B 7626707 14ACXS036-230A TXV 33,400 15.10 12.50 CH35-36B EL180UH090XE48B 7782732 14ACXS036-230A TXV 33,000 15.00 12.50 CH35-36B EL195UH045XE36B 7626710 14ACXS036-230A TXV 33,200 14.50 12.00 CH35-36B EL195UH070XE36B 7626714 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 96 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 33,000 15.00 12.50 CH35-36B EL296UH045XE36B 7782733 14ACXS036-230A TXV 33,600 15.00 12.20 CH35-36B EL296UH045XV36B 7626717 14ACXS036-230A TXV 33,200 14.50 12.00 CH35-36B EL296UH070XE36B 7782734 14ACXS036-230A TXV 33,400 15.00 12.50 CH35-36B EL296UH070XV36B 7782735 14ACXS036-230A TXV 33,600 15.50 12.50 CH35-36B SL280UH090V36B 7782729 14ACXS036-230A TXV 33,800 15.50 12.50 CH35-36B SL280UH090V48B 7626701 14ACXS036-230A TXV 33,800 15.50 12.50 CH35-36B SL280UH090XV48B 7782730 14ACXS036-230A TXV 33,400 15.00 12.50 CH35-36B SLP98UH070XV36B 7626720 14ACXS036-230A TXV 33,000 14.00 11.50 CH35-36B 7626698 14ACXS036-230A TXV 34,000 15.50 12.50 CH35-36C EL180UH090E60C 7626727 14ACXS036-230A TXV 33,800 15.50 12.50 CH35-36C EL180UH110E60C 7782738 14ACXS036-230A TXV 33,800 15.50 12.50 CH35-36C EL180UH110XE60C 7626730 14ACXS036-230A TXV 33,600 15.10 12.50 CH35-36C EL195UH090XE48C 7782739 14ACXS036-230A TXV 34,000 15.50 12.50 CH35-36C EL195UH110XE60C 7782740 14ACXS036-230A TXV 33,600 15.10 12.50 CH35-36C EL296UH090XE48C 7626733 14ACXS036-230A TXV 34,000 15.50 12.50 CH35-36C EL296UH090XV36C 7782741 14ACXS036-230A TXV 33,800 15.50 12.50 CH35-36C EL296UH090XV48C 7782742 14ACXS036-230A TXV 34,000 15.50 12.50 CH35-36C EL296UH110XE60C 7626736 14ACXS036-230A TXV 34,000 15.50 12.50 CH35-36C EL296UH110XV48C 7782743 14ACXS036-230A TXV 34,400 15.50 12.50 CH35-36C EL296UH110XV60C 7783195 14ACXS036-230A TXV 34,400 15.50 12.50 CH35-36C SL280UH090V60C 7783194 14ACXS036-230A TXV 34,400 15.50 12.50 CH35-36C SL280UH090XV60C 7628435 14ACXS036-230A TXV 34,200 15.50 12.50 CH35-36C SL280UH110V60C 7626723 14ACXS036-230A TXV 34,200 15.50 12.50 CH35-36C SL280UH110XV60C 7782737 14ACXS036-230A TXV 34,000 15.50 12.50 CH35-36C SLP98UH090XV36C 7626739 14ACXS036-230A TXV 33,800 15.50 12.50 CH35-36C SLP98UH090XV48C 7626743 14ACXS036-230A TXV 34,400 15.50 12.50 CH35-36C SLP98UH110XV60C 7626746 14ACXS036-230A TXV 33,400 14.25 11.50 CH35-36C 7782736 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-42B EL180UH070E36B 7782746 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-42B EL180UH070XE36B 7626755 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-42B EL180UH090E48B 7782747 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-42B EL180UH090XE48B 7626759 14ACXS036-230A TXV 35,000 15.10 12.50 CH35-42B EL195UH045XE36B 7782748 14ACXS036-230A TXV 35,200 15.10 12.50 CH35-42B EL195UH070XE36B 7782749 14ACXS036-230A TXV 35,000 15.10 12.50 CH35-42B EL296UH045XE36B 7626762 14ACXS036-230A TXV 35,400 15.50 12.50 CH35-42B EL296UH045XV36B 7782750 14ACXS036-230A TXV 35,200 15.10 12.50 CH35-42B EL296UH070XE36B 7626765 14ACXS036-230A TXV 35,400 15.50 12.50 CH35-42B EL296UH070XV36B 7626768 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-42B SL280UH090V36B 7626749 14ACXS036-230A TXV 35,600 16.00 13.00 CH35-42B SL280UH090V48B 7782745 14ACXS036-230A TXV 35,600 16.00 13.00 CH35-42B SL280UH090XV48B 7626752 14ACXS036-230A TXV 35,400 15.50 12.50 CH35-42B SLP98UH070XV36B 7782751 14ACXS036-230A TXV 35,000 14.50 12.20 CH35-42B 7782744 14ACXS036-230A TXV 35,200 16.00 13.00 CH35-42C EL180UH090E60C 7782754 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-42C EL180UH110E60C 7626781 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-42C EL180UH110XE60C 7782755 14ACXS036-230A TXV 34,800 16.00 13.00 CH35-42C EL195UH090XE48C 7626784 14ACXS036-230A TXV 35,200 16.00 13.00 CH35-42C EL195UH110XE60C 7626787 14ACXS036-230A TXV 34,800 16.00 13.00 CH35-42C EL296UH090XE48C 7782756 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 97 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 35,200 16.00 13.00 CH35-42C EL296UH090XV36C 7626791 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-42C EL296UH090XV48C 7626794 14ACXS036-230A TXV 35,200 16.00 13.00 CH35-42C EL296UH110XE60C 7782757 14ACXS036-230A TXV 35,200 16.00 13.00 CH35-42C EL296UH110XV48C 7626799 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-42C EL296UH110XV60C 7626802 14ACXS036-230A TXV 35,600 16.00 13.00 CH35-42C SL280UH090V60C 7782752 14ACXS036-230A TXV 35,600 16.00 13.00 CH35-42C SL280UH090XV60C 7626775 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-42C SL280UH110V60C 7782753 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-42C SL280UH110XV60C 7626778 14ACXS036-230A TXV 35,200 16.00 13.00 CH35-42C SLP98UH090XV36C 7782758 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-42C SLP98UH090XV48C 7626796 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-42C SLP98UH110XV60C 7782759 14ACXS036-230A TXV 34,600 14.50 12.20 CH35-42C 7626772 14ACXS036-230A TXV 34,800 15.10 12.50 CH35-48B EL180UH070E36B 7626813 14ACXS036-230A TXV 34,800 15.10 12.50 CH35-48B EL180UH070XE36B 7626816 14ACXS036-230A TXV 34,800 16.00 13.00 CH35-48B EL180UH090E48B 7626818 14ACXS036-230A TXV 34,800 16.00 13.00 CH35-48B EL180UH090XE48B 7782761 14ACXS036-230A TXV 34,400 15.00 12.20 CH35-48B EL195UH045XE36B 7626821 14ACXS036-230A TXV 34,600 15.00 12.50 CH35-48B EL195UH070XE36B 7626827 14ACXS036-230A TXV 34,400 15.00 12.20 CH35-48B EL296UH045XE36B 7626824 14ACXS036-230A TXV 35,000 15.10 12.50 CH35-48B EL296UH045XV36B 7626832 14ACXS036-230A TXV 34,600 15.00 12.50 CH35-48B EL296UH070XE36B 7626829 14ACXS036-230A TXV 34,800 15.50 12.50 CH35-48B EL296UH070XV36B 7626835 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-48B SL280UH090V36B 7782760 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-48B SL280UH090V48B 7626808 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-48B SL280UH090XV48B 7626811 14ACXS036-230A TXV 34,800 15.50 12.50 CH35-48B SLP98UH070XV36B 7626837 14ACXS036-230A TXV 34,400 14.50 12.20 CH35-48B 7626805 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-48C EL180UH090E60C 7626853 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-48C EL180UH110E60C 7782762 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-48C EL180UH110XE60C 7626856 14ACXS036-230A TXV 34,800 16.00 13.00 CH35-48C EL195UH090XE48C 7782763 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-48C EL195UH110XE60C 7782764 14ACXS036-230A TXV 34,800 16.00 13.00 CH35-48C EL296UH090XE48C 7626859 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-48C EL296UH090XV36C 7782765 14ACXS036-230A TXV 34,800 16.00 13.00 CH35-48C EL296UH090XV48C 7782766 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-48C EL296UH110XE60C 7626863 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-48C EL296UH110XV48C 7782767 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-48C EL296UH110XV60C 7626872 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-48C SL280UH090V60C 7626843 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-48C SL280UH090XV60C 7626845 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-48C SL280UH110V60C 7626848 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-48C SL280UH110XV60C 7626851 14ACXS036-230A TXV 35,000 16.00 13.00 CH35-48C SLP98UH090XV36C 7626866 14ACXS036-230A TXV 34,800 16.00 13.00 CH35-48C SLP98UH090XV48C 7626869 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-48C SLP98UH110XV60C 7626874 14ACXS036-230A TXV 34,400 14.50 12.20 CH35-48C 7626840 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-51C EL180UH090E60C 7782769 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-51C EL180UH110E60C 7626888 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 98 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-51C EL180UH110XE60C 7782770 14ACXS036-230A TXV 35,200 16.00 13.00 CH35-51C EL195UH090XE48C 7626891 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-51C EL195UH110XE60C 7626894 14ACXS036-230A TXV 35,200 16.00 13.00 CH35-51C EL296UH090XE48C 7782771 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-51C EL296UH090XV36C 7626897 14ACXS036-230A TXV 35,200 16.00 13.00 CH35-51C EL296UH090XV48C 7626900 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-51C EL296UH110XE60C 7782772 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-51C EL296UH110XV48C 7626903 14ACXS036-230A TXV 35,800 16.00 13.00 CH35-51C EL296UH110XV60C 7782775 14ACXS036-230A TXV 36,000 16.00 13.00 CH35-51C SL280UH090V60C 7626880 14ACXS036-230A TXV 36,000 16.00 13.00 CH35-51C SL280UH090XV60C 7626882 14ACXS036-230A TXV 35,800 16.00 13.00 CH35-51C SL280UH110V60C 7782768 14ACXS036-230A TXV 35,800 16.00 13.00 CH35-51C SL280UH110XV60C 7626885 14ACXS036-230A TXV 35,400 16.00 13.00 CH35-51C SLP98UH090XV36C 7782773 14ACXS036-230A TXV 35,200 16.00 13.00 CH35-51C SLP98UH090XV48C 7782774 14ACXS036-230A TXV 35,800 16.00 13.00 CH35-51C SLP98UH110XV60C 7626906 14ACXS036-230A TXV 34,800 14.50 12.20 CH35-51C 7626877 14ACXS036-230A TXV 33,600 14.50 12.20 CR33-30/36A EL180DF045E36A 7626909 14ACXS036-230A TXV 33,600 15.00 12.50 CR33-30/36A SL280DF070V36A 7782776 14ACXS036-230A TXV 33,600 15.50 12.50 CR33-30/36B EL180DF070E36B 7782778 14ACXS036-230A TXV 33,600 15.10 12.50 CR33-30/36B EL180DF090E48B 7626916 14ACXS036-230A TXV 33,400 14.50 12.00 CR33-30/36B EL195DF045XE36B 7782779 14ACXS036-230A TXV 33,600 15.10 12.50 CR33-30/36B EL195DF070XE48B 7782780 14ACXS036-230A TXV 33,400 14.50 12.00 CR33-30/36B EL296DF045XE36B 7626919 14ACXS036-230A TXV 33,600 15.00 12.20 CR33-30/36B EL296DF045XV36B 7626924 14ACXS036-230A TXV 33,600 15.10 12.50 CR33-30/36B EL296DF070XE48B 7626922 14ACXS036-230A TXV 33,600 14.50 12.20 CR33-30/36B EL296DF070XV48B 7626927 14ACXS036-230A TXV 33,800 15.10 12.50 CR33-30/36B SL280DF090V48B 7626913 14ACXS036-230A TXV 33,800 15.00 12.50 CR33-30/36B SLP98DF070XV36B 7626930 14ACXS036-230A TXV 33,400 14.25 11.50 CR33-30/36B 7782777 14ACXS036-230A TXV 33,800 15.50 12.50 CR33-30/36C EL180DF110E60C 7626938 14ACXS036-230A TXV 33,600 15.10 12.50 CR33-30/36C EL195DF090XE48C 7626940 14ACXS036-230A TXV 33,600 15.10 12.50 CR33-30/36C EL195DF110XE60C 7782781 14ACXS036-230A TXV 33,600 15.10 12.50 CR33-30/36C EL296DF090XE48C 7626943 14ACXS036-230A TXV 34,000 15.10 12.50 CR33-30/36C EL296DF090XV60C 7782783 14ACXS036-230A TXV 33,600 15.10 12.50 CR33-30/36C EL296DF110XE60C 7626946 14ACXS036-230A TXV 34,000 15.10 12.50 CR33-30/36C EL296DF110XV60C 7782784 14ACXS036-230A TXV 34,000 15.50 12.50 CR33-30/36C SL280DF110V60C 7626935 14ACXS036-230A TXV 33,800 15.10 12.50 CR33-30/36C SLP98DF090XV36C 7782782 14ACXS036-230A TXV 33,800 15.10 12.50 CR33-30/36C SLP98DF090XV48C 7626949 14ACXS036-230A TXV 34,000 15.10 12.50 CR33-30/36C SLP98DF090XV60C 7626952 14ACXS036-230A TXV 34,000 15.10 12.50 CR33-30/36C SLP98DF110XV60C 7626955 14ACXS036-230A TXV 33,400 14.25 11.50 CR33-30/36C 7626932 14ACXS036-230A TXV 34,200 15.00 12.50 CR33-48B EL180DF070E36B 7783197 14ACXS036-230A TXV 34,200 15.50 12.50 CR33-48B EL180DF090E48B 7628444 14ACXS036-230A TXV 34,000 15.10 12.50 CR33-48B EL195DF045XE36B 7783198 14ACXS036-230A TXV 34,000 15.50 12.50 CR33-48B EL195DF070XE48B 7783199 14ACXS036-230A TXV 34,000 15.50 12.50 CR33-48B EL296DF045XE36B 7628447 14ACXS036-230A TXV 34,200 15.10 12.50 CR33-48B EL296DF045XV36B 7783200 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 99 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 34,000 15.50 12.50 CR33-48B EL296DF070XE48B 7628450 14ACXS036-230A TXV 34,200 15.10 12.50 CR33-48B EL296DF070XV48B 7628453 14ACXS036-230A TXV 34,600 15.50 12.50 CR33-48B SL280DF090V48B 7628441 14ACXS036-230A TXV 34,000 15.50 12.50 CR33-48B SLP98DF070XV36B 7783201 14ACXS036-230A TXV 33,800 14.25 12.00 CR33-48B 7783196 14ACXS036-230A TXV 34,400 16.00 13.00 CR33-48C EL180DF110E60C 7783203 14ACXS036-230A TXV 34,200 15.50 12.50 CR33-48C EL195DF090XE48C 7628462 14ACXS036-230A TXV 34,200 15.50 12.50 CR33-48C EL195DF110XE60C 7628465 14ACXS036-230A TXV 34,200 15.50 12.50 CR33-48C EL296DF090XE48C 7783204 14ACXS036-230A TXV 34,600 15.50 12.50 CR33-48C EL296DF090XV60C 7628471 14ACXS036-230A TXV 34,200 15.50 12.50 CR33-48C EL296DF110XE60C 7783205 14ACXS036-230A TXV 34,600 15.50 12.50 CR33-48C EL296DF110XV60C 7628474 14ACXS036-230A TXV 34,600 16.00 13.00 CR33-48C SL280DF110V60C 7628459 14ACXS036-230A TXV 34,400 15.50 12.50 CR33-48C SLP98DF090XV36C 7628468 14ACXS036-230A TXV 34,400 16.00 13.00 CR33-48C SLP98DF090XV48C 7783206 14ACXS036-230A TXV 34,600 15.50 12.50 CR33-48C SLP98DF090XV60C 7783207 14ACXS036-230A TXV 34,600 15.50 12.50 CR33-48C SLP98DF110XV60C 7783208 14ACXS036-230A TXV 33,800 14.25 12.00 CR33-48C 7783202 14ACXS036-230A TXV 34,200 15.10 12.50 CX34-31A EL180UH045E36A 7626961 14ACXS036-230A TXV 34,200 15.10 12.50 CX34-31A EL180UH045XE36A 7782787 14ACXS036-230A TXV 34,400 15.10 12.50 CX34-31A SL280UH070V36A 7626958 14ACXS036-230A TXV 34,400 15.10 12.50 CX34-31A SL280UH070XV36A 7782786 14ACXS036-230A TXV 34,000 14.50 12.00 CX34-31A 7782785 14ACXS036-230A TXV 34,400 15.00 12.50 CX34-31B EL180UH070E36B 7626972 14ACXS036-230A TXV 34,400 15.00 12.50 CX34-31B EL180UH070XE36B 7782789 14ACXS036-230A TXV 34,400 15.50 12.50 CX34-31B EL180UH090E48B 7626975 14ACXS036-230A TXV 34,400 15.50 12.50 CX34-31B EL180UH090XE48B 7782790 14ACXS036-230A TXV 34,000 14.50 12.20 CX34-31B EL195UH045XE36B 7626978 14ACXS036-230A TXV 34,000 15.10 12.50 CX34-31B EL195UH070XE36B 7626981 14ACXS036-230A TXV 34,000 14.50 12.20 CX34-31B EL296UH045XE36B 7782791 14ACXS036-230A TXV 34,200 15.10 12.50 CX34-31B EL296UH045XV36B 7626984 14ACXS036-230A TXV 34,000 15.10 12.50 CX34-31B EL296UH070XE36B 7782792 14ACXS036-230A TXV 34,200 15.10 12.50 CX34-31B EL296UH070XV36B 7782793 14ACXS036-230A TXV 34,400 15.50 12.50 CX34-31B SL280UH090V36B 7782788 14ACXS036-230A TXV 34,400 15.50 12.50 CX34-31B SL280UH090V48B 7626967 14ACXS036-230A TXV 34,400 15.50 12.50 CX34-31B SL280UH090XV48B 7626970 14ACXS036-230A TXV 34,200 15.10 12.50 CX34-31B SLP98UH070XV36B 7626987 14ACXS036-230A TXV 34,000 14.50 12.00 CX34-31B 7626964 14ACXS036-230A TXV 33,200 14.50 12.20 CX34-36A EL180UH045E36A 7626993 14ACXS036-230A TXV 33,200 14.50 12.20 CX34-36A EL180UH045XE36A 7782796 14ACXS036-230A TXV 33,400 15.00 12.20 CX34-36A SL280UH070V36A 7626990 14ACXS036-230A TXV 33,400 15.00 12.20 CX34-36A SL280UH070XV36A 7782795 14ACXS036-230A TXV 33,000 14.00 11.50 CX34-36A 7782794 14ACXS036-230A TXV 33,400 15.50 12.50 CX34-36B EL180UH070E36B 7627002 14ACXS036-230A TXV 33,400 15.50 12.50 CX34-36B EL180UH070XE36B 7782799 14ACXS036-230A TXV 33,400 15.10 12.50 CX34-36B EL180UH090E48B 7627005 14ACXS036-230A TXV 33,400 15.10 12.50 CX34-36B EL180UH090XE48B 7782800 14ACXS036-230A TXV 33,000 15.00 12.50 CX34-36B EL195UH045XE36B 7627008 14ACXS036-230A TXV 33,200 14.50 12.00 CX34-36B EL195UH070XE36B 7627011 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 100 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 33,000 15.00 12.50 CX34-36B EL296UH045XE36B 7782801 14ACXS036-230A TXV 33,400 15.00 12.50 CX34-36B EL296UH045XV36B 7627014 14ACXS036-230A TXV 33,200 14.50 12.00 CX34-36B EL296UH070XE36B 7782802 14ACXS036-230A TXV 33,400 15.00 12.50 CX34-36B EL296UH070XV36B 7782803 14ACXS036-230A TXV 33,600 15.50 12.50 CX34-36B SL280UH090V36B 7782797 14ACXS036-230A TXV 33,600 15.50 12.50 CX34-36B SL280UH090V48B 7626999 14ACXS036-230A TXV 33,600 15.50 12.50 CX34-36B SL280UH090XV48B 7782798 14ACXS036-230A TXV 33,400 15.00 12.50 CX34-36B SLP98UH070XV36B 7627017 14ACXS036-230A TXV 33,000 14.00 11.50 CX34-36B 7626996 14ACXS036-230A TXV 33,600 15.10 12.50 CX34-36C EL180UH090E60C 7627020 14ACXS036-230A TXV 33,400 15.50 12.50 CX34-36C EL180UH110E60C 7782805 14ACXS036-230A TXV 33,400 15.50 12.50 CX34-36C EL180UH110XE60C 7627023 14ACXS036-230A TXV 33,200 15.10 12.50 CX34-36C EL195UH090XE48C 7782806 14ACXS036-230A TXV 33,600 15.10 12.50 CX34-36C EL195UH110XE60C 7782807 14ACXS036-230A TXV 33,200 15.10 12.50 CX34-36C EL296UH090XE48C 7627026 14ACXS036-230A TXV 33,600 15.50 12.50 CX34-36C EL296UH090XV36C 7782808 14ACXS036-230A TXV 33,400 15.50 12.50 CX34-36C EL296UH090XV48C 7782809 14ACXS036-230A TXV 33,600 15.10 12.50 CX34-36C EL296UH110XE60C 7627029 14ACXS036-230A TXV 33,600 15.50 12.50 CX34-36C EL296UH110XV48C 7782810 14ACXS036-230A TXV 33,600 15.50 12.50 CX34-36C SLP98UH090XV36C 7627032 14ACXS036-230A TXV 33,400 15.50 12.50 CX34-36C SLP98UH090XV48C 7627035 14ACXS036-230A TXV 33,800 15.50 12.50 CX34-36C SLP98UH110XV60C 7628477 14ACXS036-230A TXV 33,000 14.00 11.50 CX34-36C 7782804 14ACXS036-230A TXV 34,400 15.10 12.50 CX34-38A EL180UH045E36A 7782812 14ACXS036-230A TXV 34,400 15.10 12.50 CX34-38A EL180UH045XE36A 7627044 14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38A SL280UH070V36A 7782811 14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38A SL280UH070XV36A 7627041 14ACXS036-230A TXV 34,200 14.50 12.20 CX34-38A 7627038 14ACXS036-230A TXV 34,600 16.00 13.00 CX34-38B EL180UH070E36B 7627050 14ACXS036-230A TXV 34,600 16.00 13.00 CX34-38B EL180UH070XE36B 7782815 14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B EL180UH090E48B 7627053 14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B EL180UH090XE48B 7782816 14ACXS036-230A TXV 34,400 15.00 12.50 CX34-38B EL195UH045XE36B 7627056 14ACXS036-230A TXV 34,400 15.00 12.50 CX34-38B EL195UH070XE36B 7627059 14ACXS036-230A TXV 34,400 15.00 12.50 CX34-38B EL296UH045XE36B 7782817 14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B EL296UH045XV36B 7627062 14ACXS036-230A TXV 34,400 15.00 12.50 CX34-38B EL296UH070XE36B 7782818 14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B EL296UH070XV36B 7782819 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-38B SL280UH090V36B 7782813 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-38B SL280UH090V48B 7627047 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-38B SL280UH090XV48B 7782814 14ACXS036-230A TXV 34,600 15.50 12.50 CX34-38B SLP98UH070XV36B 7627065 14ACXS036-230A TXV 34,200 14.25 12.20 CX34-38B 7626099 14ACXS036-230A TXV 33,400 15.50 12.50 CX34-42 EL180UH070E36B 7783211 14ACXS036-230A TXV 33,400 15.50 12.50 CX34-42 EL180UH070XE36B 7628486 14ACXS036-230A TXV 33,400 15.10 12.50 CX34-42 EL180UH090E48B 7783212 14ACXS036-230A TXV 33,400 15.10 12.50 CX34-42 EL180UH090XE48B 7628489 14ACXS036-230A TXV 33,000 15.00 12.50 CX34-42 EL195UH045XE36B 7783213 14ACXS036-230A TXV 33,200 14.50 12.00 CX34-42 EL195UH070XE36B 7783214 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 101 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 33,000 15.00 12.50 CX34-42 EL296UH045XE36B 7628493 14ACXS036-230A TXV 33,400 15.00 12.50 CX34-42 EL296UH045XV36B 7783215 14ACXS036-230A TXV 33,200 14.50 12.00 CX34-42 EL296UH070XE36B 7628496 14ACXS036-230A TXV 33,400 15.00 12.50 CX34-42 EL296UH070XV36B 7628498 14ACXS036-230A TXV 33,600 15.50 12.50 CX34-42 SL280UH090V36B 7628480 14ACXS036-230A TXV 33,600 15.50 12.50 CX34-42 SL280UH090V48B 7783210 14ACXS036-230A TXV 33,600 15.50 12.50 CX34-42 SL280UH090XV48B 7628483 14ACXS036-230A TXV 33,400 15.00 12.50 CX34-42 SLP98UH070XV36B 7783216 14ACXS036-230A TXV 33,000 14.00 11.50 CX34-42 7783209 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43B EL180UH070E36B 7782822 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43B EL180UH070XE36B 7627075 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43B EL180UH090E48B 7782823 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43B EL180UH090XE48B 7627078 14ACXS036-230A TXV 34,400 15.00 12.50 CX34-43B EL195UH045XE36B 7627080 14ACXS036-230A TXV 34,600 15.10 12.50 CX34-43B EL195UH070XE36B 7627086 14ACXS036-230A TXV 34,400 15.00 12.50 CX34-43B EL296UH045XE36B 7627083 14ACXS036-230A TXV 34,800 15.50 12.50 CX34-43B EL296UH045XV36B 7627091 14ACXS036-230A TXV 34,600 15.10 12.50 CX34-43B EL296UH070XE36B 7627088 14ACXS036-230A TXV 34,800 15.50 12.50 CX34-43B EL296UH070XV36B 7627094 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43B SL280UH090V36B 7627069 14ACXS036-230A TXV 35,000 16.00 13.00 CX34-43B SL280UH090V48B 7782821 14ACXS036-230A TXV 35,000 16.00 13.00 CX34-43B SL280UH090XV48B 7627072 14ACXS036-230A TXV 34,800 15.50 12.50 CX34-43B SLP98UH070XV36B 7627096 14ACXS036-230A TXV 34,400 14.50 12.20 CX34-43B 7782820 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43C EL180UH090E60C 7627108 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43C EL180UH110E60C 7627109 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43C EL180UH110XE60C 7782826 14ACXS036-230A TXV 34,600 15.50 12.50 CX34-43C EL195UH090XE48C 7782827 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43C EL195UH110XE60C 7782828 14ACXS036-230A TXV 34,600 15.50 12.50 CX34-43C EL296UH090XE48C 7627114 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43C EL296UH090XV36C 7782829 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43C EL296UH090XV48C 7782830 14ACXS036-230A TXV 34,600 16.00 13.00 CX34-43C EL296UH110XE60C 7627117 14ACXS036-230A TXV 35,000 16.00 13.00 CX34-43C EL296UH110XV48C 7782831 14ACXS036-230A TXV 35,200 16.00 13.00 CX34-43C EL296UH110XV60C 7627126 14ACXS036-230A TXV 35,400 16.00 13.00 CX34-43C SL280UH090V60C 7782824 14ACXS036-230A TXV 35,400 16.00 13.00 CX34-43C SL280UH090XV60C 7627101 14ACXS036-230A TXV 35,200 16.00 13.00 CX34-43C SL280UH110V60C 7782825 14ACXS036-230A TXV 35,200 16.00 13.00 CX34-43C SL280UH110XV60C 7627105 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43C SLP98UH090XV36C 7627120 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-43C SLP98UH090XV48C 7627123 14ACXS036-230A TXV 35,200 16.00 13.00 CX34-43C SLP98UH110XV60C 7782832 14ACXS036-230A TXV 34,400 14.50 12.20 CX34-43C 7627098 14ACXS036-230A TXV 34,200 16.00 13.00 CX34-44/48B EL180UH070E36B 7627135 14ACXS036-230A TXV 34,200 16.00 13.00 CX34-44/48B EL180UH070XE36B 7782835 14ACXS036-230A TXV 34,200 15.50 12.50 CX34-44/48B EL180UH090E48B 7627138 14ACXS036-230A TXV 34,200 15.50 12.50 CX34-44/48B EL180UH090XE48B 7782836 14ACXS036-230A TXV 33,800 15.10 12.50 CX34-44/48B EL195UH045XE36B 7627141 14ACXS036-230A TXV 34,200 15.00 12.50 CX34-44/48B EL195UH070XE36B 7627144 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 102 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 33,800 15.10 12.50 CX34-44/48B EL296UH045XE36B 7782837 14ACXS036-230A TXV 34,200 15.10 12.50 CX34-44/48B EL296UH045XV36B 7627147 14ACXS036-230A TXV 34,200 15.00 12.50 CX34-44/48B EL296UH070XE36B 7782838 14ACXS036-230A TXV 34,200 15.10 12.50 CX34-44/48B EL296UH070XV36B 7782839 14ACXS036-230A TXV 34,400 16.00 13.00 CX34-44/48B SL280UH090V36B 7782833 14ACXS036-230A TXV 34,400 16.00 13.00 CX34-44/48B SL280UH090V48B 7627132 14ACXS036-230A TXV 34,400 16.00 13.00 CX34-44/48B SL280UH090XV48B 7782834 14ACXS036-230A TXV 34,200 15.10 12.50 CX34-44/48B SLP98UH070XV36B 7627150 14ACXS036-230A TXV 33,800 14.50 12.00 CX34-44/48B 7627129 14ACXS036-230A TXV 34,400 15.50 12.50 CX34-44/48C EL180UH090E60C 7627159 14ACXS036-230A TXV 34,400 16.00 13.00 CX34-44/48C EL180UH110E60C 7782843 14ACXS036-230A TXV 34,400 16.00 13.00 CX34-44/48C EL180UH110XE60C 7627162 14ACXS036-230A TXV 34,200 15.50 12.50 CX34-44/48C EL195UH090XE48C 7782844 14ACXS036-230A TXV 34,400 15.50 12.50 CX34-44/48C EL195UH110XE60C 7782845 14ACXS036-230A TXV 34,200 15.50 12.50 CX34-44/48C EL296UH090XE48C 7627166 14ACXS036-230A TXV 34,400 15.50 12.50 CX34-44/48C EL296UH090XV36C 7782846 14ACXS036-230A TXV 34,200 16.00 13.00 CX34-44/48C EL296UH090XV48C 7782847 14ACXS036-230A TXV 34,200 15.50 12.50 CX34-44/48C EL296UH110XE60C 7627169 14ACXS036-230A TXV 34,400 16.00 13.00 CX34-44/48C EL296UH110XV48C 7782848 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-44/48C EL296UH110XV60C 7627178 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-44/48C SL280UH090V60C 7627153 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-44/48C SL280UH090XV60C 7782841 14ACXS036-230A TXV 34,600 15.50 12.50 CX34-44/48C SL280UH110V60C 7627156 14ACXS036-230A TXV 34,600 15.50 12.50 CX34-44/48C SL280UH110XV60C 7782842 14ACXS036-230A TXV 34,400 15.50 12.50 CX34-44/48C SLP98UH090XV36C 7627172 14ACXS036-230A TXV 34,200 16.00 13.00 CX34-44/48C SLP98UH090XV48C 7627175 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-44/48C SLP98UH110XV60C 7782849 14ACXS036-230A TXV 33,800 14.50 12.00 CX34-44/48C 7782840 14ACXS036-230A TXV 35,200 16.00 13.00 CX34-49 EL180UH090E60C 7783219 14ACXS036-230A TXV 35,000 16.00 13.00 CX34-49 EL180UH110E60C 7628511 14ACXS036-230A TXV 35,000 16.00 13.00 CX34-49 EL180UH110XE60C 7783220 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-49 EL195UH090XE48C 7628514 14ACXS036-230A TXV 35,200 16.00 13.00 CX34-49 EL195UH110XE60C 7628517 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-49 EL296UH090XE48C 7783221 14ACXS036-230A TXV 35,200 16.00 13.00 CX34-49 EL296UH090XV36C 7628520 14ACXS036-230A TXV 35,000 16.00 13.00 CX34-49 EL296UH090XV48C 7628523 14ACXS036-230A TXV 35,200 16.00 13.00 CX34-49 EL296UH110XE60C 7783222 14ACXS036-230A TXV 35,200 16.00 13.00 CX34-49 EL296UH110XV48C 7628526 14ACXS036-230A TXV 35,600 16.00 13.00 CX34-49 EL296UH110XV60C 7783225 14ACXS036-230A TXV 35,600 16.00 13.00 CX34-49 SL280UH090V60C 7783217 14ACXS036-230A TXV 35,600 16.00 13.00 CX34-49 SL280UH090XV60C 7628505 14ACXS036-230A TXV 35,400 16.00 13.00 CX34-49 SL280UH110V60C 7783218 14ACXS036-230A TXV 35,400 16.00 13.00 CX34-49 SL280UH110XV60C 7628508 14ACXS036-230A TXV 35,200 16.00 13.00 CX34-49 SLP98UH090XV36C 7783223 14ACXS036-230A TXV 35,000 16.00 13.00 CX34-49 SLP98UH090XV48C 7783224 14ACXS036-230A TXV 35,600 16.00 13.00 CX34-49 SLP98UH110XV60C 7628529 14ACXS036-230A TXV 34,600 14.50 12.20 CX34-49 7628502 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-50/60C EL180UH090E60C 7627190 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-50/60C EL180UH110E60C 7782852 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 103 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-50/60C EL180UH110XE60C 7627194 14ACXS036-230A TXV 34,600 15.50 12.50 CX34-50/60C EL195UH090XE48C 7627197 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-50/60C EL195UH110XE60C 7627202 14ACXS036-230A TXV 34,600 15.50 12.50 CX34-50/60C EL296UH090XE48C 7627200 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-50/60C EL296UH090XV36C 7627208 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-50/60C EL296UH090XV48C 7627211 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-50/60C EL296UH110XE60C 7627205 14ACXS036-230A TXV 35,000 16.00 13.00 CX34-50/60C EL296UH110XV48C 7627214 14ACXS036-230A TXV 35,200 16.00 13.00 CX34-50/60C EL296UH110XV60C 7782855 14ACXS036-230A TXV 35,200 16.00 13.00 CX34-50/60C SL280UH090V60C 7782850 14ACXS036-230A TXV 35,200 16.00 13.00 CX34-50/60C SL280UH090XV60C 7627185 14ACXS036-230A TXV 35,000 16.00 13.00 CX34-50/60C SL280UH110V60C 7782851 14ACXS036-230A TXV 35,000 16.00 13.00 CX34-50/60C SL280UH110XV60C 7627188 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-50/60C SLP98UH090XV36C 7782853 14ACXS036-230A TXV 34,800 16.00 13.00 CX34-50/60C SLP98UH090XV48C 7782854 14ACXS036-230A TXV 35,200 16.00 13.00 CX34-50/60C SLP98UH110XV60C 7627218 14ACXS036-230A TXV 34,200 14.50 12.20 CX34-50/60C 7627182 14ACXS036-230A TXV 33,200 14.50 12.20 CX35-30/36A EL180UH045E36A 8259176 14ACXS036-230A TXV 33,200 14.50 12.20 CX35-30/36A EL180UH045XE36A 8259173 14ACXS036-230A TXV 33,400 15.00 12.20 CX35-30/36A SL280UH070V36A 8259175 14ACXS036-230A TXV 33,400 15.00 12.20 CX35-30/36A SL280UH070XV36A 8259171 14ACXS036-230A TXV 33,000 14.00 11.50 CX35-30/36A 8259170 14ACXS036-230A TXV 33,400 15.50 12.50 CX35-30/36B EL180UH070E36B 8259191 14ACXS036-230A TXV 33,400 15.50 12.50 CX35-30/36B EL180UH070XE36B 8259180 14ACXS036-230A TXV 33,400 15.10 12.50 CX35-30/36B EL180UH090E48B 8259193 14ACXS036-230A TXV 33,400 15.10 12.50 CX35-30/36B EL180UH090XE48B 8259181 14ACXS036-230A TXV 33,000 15.00 12.50 CX35-30/36B EL195UH045XE36B 8259194 14ACXS036-230A TXV 33,200 14.50 12.00 CX35-30/36B EL195UH070XE36B 8259196 14ACXS036-230A TXV 33,000 15.00 12.50 CX35-30/36B EL296UH045XE36B 8259183 14ACXS036-230A TXV 33,400 15.00 12.50 CX35-30/36B EL296UH045XV36B 8259197 14ACXS036-230A TXV 33,200 14.50 12.00 CX35-30/36B EL296UH070XE36B 8259184 14ACXS036-230A TXV 33,400 15.00 12.50 CX35-30/36B EL296UH070XV36B 8259186 14ACXS036-230A TXV 33,600 15.50 12.50 CX35-30/36B SL280UH090V36B 8259188 14ACXS036-230A TXV 33,600 15.50 12.50 CX35-30/36B SL280UH090V48B 8259201 14ACXS036-230A TXV 33,600 15.50 12.50 CX35-30/36B SL280UH090XV48B 8259189 14ACXS036-230A TXV 33,400 15.00 12.50 CX35-30/36B SLP98UH070XV36B 8259199 14ACXS036-230A TXV 33,000 14.00 11.50 CX35-30/36B 8259178 14ACXS036-230A TXV 33,600 15.10 12.50 CX35-30/36C EL180UH090E60C 8259216 14ACXS036-230A TXV 33,400 15.50 12.50 CX35-30/36C EL180UH110E60C 8259212 14ACXS036-230A TXV 33,400 15.50 12.50 CX35-30/36C EL180UH110XE60C 8259217 14ACXS036-230A TXV 33,200 15.10 12.50 CX35-30/36C EL195UH090XE48C 8259204 14ACXS036-230A TXV 33,600 15.10 12.50 CX35-30/36C EL195UH110XE60C 8259206 14ACXS036-230A TXV 33,200 15.10 12.50 CX35-30/36C EL296UH090XE48C 8259218 14ACXS036-230A TXV 33,600 15.50 12.50 CX35-30/36C EL296UH090XV36C 8259208 14ACXS036-230A TXV 33,400 15.50 12.50 CX35-30/36C EL296UH090XV48C 8259209 14ACXS036-230A TXV 33,600 15.10 12.50 CX35-30/36C EL296UH110XE60C 8259220 14ACXS036-230A TXV 33,600 15.50 12.50 CX35-30/36C EL296UH110XV48C 8259211 14ACXS036-230A TXV 33,600 15.50 12.50 CX35-30/36C SLP98UH090XV36C 8259222 14ACXS036-230A TXV 33,400 15.50 12.50 CX35-30/36C SLP98UH090XV48C 8259223 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 104 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 33,800 15.50 12.50 CX35-30/36C SLP98UH110XV60C 8259214 14ACXS036-230A TXV 33,000 14.00 11.50 CX35-30/36C 8259203 14ACXS036-230A TXV 34,200 15.10 12.50 CX35-30A EL180UH045E36A 8259141 14ACXS036-230A TXV 34,200 15.10 12.50 CX35-30A EL180UH045XE36A 8259139 14ACXS036-230A TXV 34,400 15.10 12.50 CX35-30A SL280UH070V36A 8259143 14ACXS036-230A TXV 34,400 15.10 12.50 CX35-30A SL280UH070XV36A 8259138 14ACXS036-230A TXV 34,000 14.50 12.00 CX35-30A 8259136 14ACXS036-230A TXV 34,400 15.00 12.50 CX35-30B EL180UH070E36B 8259164 14ACXS036-230A TXV 34,400 15.00 12.50 CX35-30B EL180UH070XE36B 8259151 14ACXS036-230A TXV 34,400 15.50 12.50 CX35-30B EL180UH090E48B 8259166 14ACXS036-230A TXV 34,400 15.50 12.50 CX35-30B EL180UH090XE48B 8259153 14ACXS036-230A TXV 34,000 14.50 12.20 CX35-30B EL195UH045XE36B 8259168 14ACXS036-230A TXV 34,000 15.10 12.50 CX35-30B EL195UH070XE36B 8259156 14ACXS036-230A TXV 34,000 14.50 12.20 CX35-30B EL296UH045XE36B 8259154 14ACXS036-230A TXV 34,200 15.10 12.50 CX35-30B EL296UH045XV36B 8259158 14ACXS036-230A TXV 34,000 15.10 12.50 CX35-30B EL296UH070XE36B 8259146 14ACXS036-230A TXV 34,200 15.10 12.50 CX35-30B EL296UH070XV36B 8259148 14ACXS036-230A TXV 34,400 15.50 12.50 CX35-30B SL280UH090V36B 8259149 14ACXS036-230A TXV 34,400 15.50 12.50 CX35-30B SL280UH090V48B 8259161 14ACXS036-230A TXV 34,400 15.50 12.50 CX35-30B SL280UH090XV48B 8259163 14ACXS036-230A TXV 34,200 15.10 12.50 CX35-30B SLP98UH070XV36B 8259159 14ACXS036-230A TXV 34,000 14.50 12.00 CX35-30B 8259144 14ACXS036-230A TXV 34,400 15.10 12.50 CX35-36A EL180UH045E36A 8259227 14ACXS036-230A TXV 34,400 15.10 12.50 CX35-36A EL180UH045XE36A 8259232 14ACXS036-230A TXV 34,600 15.50 12.50 CX35-36A SL280UH070V36A 8259228 14ACXS036-230A TXV 34,600 15.50 12.50 CX35-36A SL280UH070XV36A 8259230 14ACXS036-230A TXV 34,200 14.50 12.20 CX35-36A 8259225 14ACXS036-230A TXV 34,600 16.00 13.00 CX35-36B EL180UH070E36B 8259253 14ACXS036-230A TXV 34,600 16.00 13.00 CX35-36B EL180UH070XE36B 8259242 14ACXS036-230A TXV 34,600 16.00 13.00 CX35-36B EL180UH090E48B 8259255 14ACXS036-230A TXV 34,600 16.00 13.00 CX35-36B EL180UH090XE48B 8259243 14ACXS036-230A TXV 34,400 15.00 12.50 CX35-36B EL195UH045XE36B 8259257 14ACXS036-230A TXV 34,400 15.00 12.50 CX35-36B EL195UH070XE36B 8259247 14ACXS036-230A TXV 34,400 15.00 12.50 CX35-36B EL296UH045XE36B 8259245 14ACXS036-230A TXV 34,600 15.50 12.50 CX35-36B EL296UH045XV36B 8259248 14ACXS036-230A TXV 34,400 15.00 12.50 CX35-36B EL296UH070XE36B 8259235 14ACXS036-230A TXV 34,600 15.50 12.50 CX35-36B EL296UH070XV36B 8259237 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-36B SL280UH090V36B 8259239 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-36B SL280UH090V48B 8259252 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-36B SL280UH090XV48B 8259240 14ACXS036-230A TXV 34,600 15.50 12.50 CX35-36B SLP98UH070XV36B 8259250 14ACXS036-230A TXV 34,200 14.25 12.20 CX35-36B 8259233 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48B EL180UH070E36B 8259262 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48B EL180UH070XE36B 8259282 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48B EL180UH090E48B 8259263 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48B EL180UH090XE48B 8259269 14ACXS036-230A TXV 34,400 15.00 12.50 CX35-48B EL195UH045XE36B 8259271 14ACXS036-230A TXV 34,600 15.10 12.50 CX35-48B EL195UH070XE36B 8259274 14ACXS036-230A TXV 34,400 15.00 12.50 CX35-48B EL296UH045XE36B 8259273 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 105 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 34,800 15.50 12.50 CX35-48B EL296UH045XV36B 8259278 14ACXS036-230A TXV 34,600 15.10 12.50 CX35-48B EL296UH070XE36B 8259276 14ACXS036-230A TXV 34,800 15.50 12.50 CX35-48B EL296UH070XV36B 8259265 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48B SL280UH090V36B 8259279 14ACXS036-230A TXV 35,000 16.00 13.00 CX35-48B SL280UH090V48B 8259260 14ACXS036-230A TXV 35,000 16.00 13.00 CX35-48B SL280UH090XV48B 8259281 14ACXS036-230A TXV 34,800 15.50 12.50 CX35-48B SLP98UH070XV36B 8259267 14ACXS036-230A TXV 34,400 14.50 12.20 CX35-48B 8259258 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48C EL180UH090E60C 8259314 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48C EL180UH110E60C 8259316 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48C EL180UH110XE60C 8259291 14ACXS036-230A TXV 34,600 15.50 12.50 CX35-48C EL195UH090XE48C 8259292 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48C EL195UH110XE60C 8259294 14ACXS036-230A TXV 34,600 15.50 12.50 CX35-48C EL296UH090XE48C 8259302 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48C EL296UH090XV36C 8259297 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48C EL296UH090XV48C 8259298 14ACXS036-230A TXV 34,600 16.00 13.00 CX35-48C EL296UH110XE60C 8259303 14ACXS036-230A TXV 35,000 16.00 13.00 CX35-48C EL296UH110XV48C 8259286 14ACXS036-230A TXV 35,200 16.00 13.00 CX35-48C EL296UH110XV60C 8259308 14ACXS036-230A TXV 35,400 16.00 13.00 CX35-48C SL280UH090V60C 8259300 14ACXS036-230A TXV 35,400 16.00 13.00 CX35-48C SL280UH090XV60C 8259310 14ACXS036-230A TXV 35,200 16.00 13.00 CX35-48C SL280UH110V60C 8259289 14ACXS036-230A TXV 35,200 16.00 13.00 CX35-48C SL280UH110XV60C 8259312 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48C SLP98UH090XV36C 8259305 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-48C SLP98UH090XV48C 8259307 14ACXS036-230A TXV 35,200 16.00 13.00 CX35-48C SLP98UH110XV60C 8259287 14ACXS036-230A TXV 34,400 14.50 12.20 CX35-48C 8259284 14ACXS036-230A TXV 35,200 16.00 13.00 CX35-49C EL180UH090E60C 8259330 14ACXS036-230A TXV 35,000 16.00 13.00 CX35-49C EL180UH110E60C 8259337 14ACXS036-230A TXV 35,000 16.00 13.00 CX35-49C EL180UH110XE60C 8259332 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-49C EL195UH090XE48C 8259338 14ACXS036-230A TXV 35,200 16.00 13.00 CX35-49C EL195UH110XE60C 8259340 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-49C EL296UH090XE48C 8259333 14ACXS036-230A TXV 35,200 16.00 13.00 CX35-49C EL296UH090XV36C 8259342 14ACXS036-230A TXV 35,000 16.00 13.00 CX35-49C EL296UH090XV48C 8259343 14ACXS036-230A TXV 35,200 16.00 13.00 CX35-49C EL296UH110XE60C 8259320 14ACXS036-230A TXV 35,200 16.00 13.00 CX35-49C EL296UH110XV48C 8259345 14ACXS036-230A TXV 35,600 16.00 13.00 CX35-49C EL296UH110XV60C 8259325 14ACXS036-230A TXV 35,600 16.00 13.00 CX35-49C SL280UH090V60C 8259327 14ACXS036-230A TXV 35,600 16.00 13.00 CX35-49C SL280UH090XV60C 8259347 14ACXS036-230A TXV 35,400 16.00 13.00 CX35-49C SL280UH110V60C 8259328 14ACXS036-230A TXV 35,400 16.00 13.00 CX35-49C SL280UH110XV60C 8259348 14ACXS036-230A TXV 35,200 16.00 13.00 CX35-49C SLP98UH090XV36C 8259322 14ACXS036-230A TXV 35,000 16.00 13.00 CX35-49C SLP98UH090XV48C 8259323 14ACXS036-230A TXV 35,600 16.00 13.00 CX35-49C SLP98UH110XV60C 8259335 14ACXS036-230A TXV 34,600 14.50 12.20 CX35-49C 8259318 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL180UH090E60C 8259380 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL180UH110E60C 8259356 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL180UH110XE60C 8259367 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 106 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS036-230A TXV 34,600 15.50 12.50 CX35-50/60C EL195UH090XE48C 8259369 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL195UH110XE60C 8259372 14ACXS036-230A TXV 34,600 15.50 12.50 CX35-50/60C EL296UH090XE48C 8259371 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL296UH090XV36C 8259375 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL296UH090XV48C 8259362 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL296UH110XE60C 8259374 14ACXS036-230A TXV 35,000 16.00 13.00 CX35-50/60C EL296UH110XV48C 8259364 14ACXS036-230A TXV 35,200 16.00 13.00 CX35-50/60C EL296UH110XV60C 8259361 14ACXS036-230A TXV 35,200 16.00 13.00 CX35-50/60C SL280UH090V60C 8259352 14ACXS036-230A TXV 35,200 16.00 13.00 CX35-50/60C SL280UH090XV60C 8259377 14ACXS036-230A TXV 35,000 16.00 13.00 CX35-50/60C SL280UH110V60C 8259354 14ACXS036-230A TXV 35,000 16.00 13.00 CX35-50/60C SL280UH110XV60C 8259378 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-50/60C SLP98UH090XV36C 8259357 14ACXS036-230A TXV 34,800 16.00 13.00 CX35-50/60C SLP98UH090XV48C 8259359 14ACXS036-230A TXV 35,200 16.00 13.00 CX35-50/60C SLP98UH110XV60C 8259366 14ACXS036-230A TXV 34,200 14.50 12.20 CX35-50/60C 8259350 14ACXS042-230A RFC 41,500 14.00 12.00 C33-49 7783121 14ACXS042-230A RFC 42,000 14.25 12.20 C33-62C 7782920 14ACXS042-230A RFC 41,500 14.00 12.20 C35-49C 8471048 14ACXS042-230A RFC 41,000 14.00 12.20 C35-60D 8471050 14ACXS042-230A RFC 41,500 14.00 12.20 CH33-43B 8452500 14ACXS042-230A RFC 41,500 14.00 12.20 CH33-43C 7628211 14ACXS042-230A RFC 42,000 14.00 12.20 CH33-49 7782981 14ACXS042-230A RFC 41,500 14.00 12.20 CH33-50/60C 7782992 14ACXS042-230A TXV 39,500 14.50 12.20 C33-36B EL180UH090E48B 7782859 14ACXS042-230A TXV 39,500 14.50 12.20 C33-36B EL180UH090XE48B 7627230 14ACXS042-230A TXV 39,000 14.00 11.50 C33-36B EL296UH045XV36B 7627224 14ACXS042-230A TXV 39,000 14.00 11.50 C33-36B EL296UH070XV36B 7627227 14ACXS042-230A TXV 39,500 14.50 12.20 C33-36B SL280UH090V36B 7782856 14ACXS042-230A TXV 39,500 14.50 12.20 C33-36B SL280UH090V48B 7627221 14ACXS042-230A TXV 39,500 14.50 12.20 C33-36B SL280UH090XV48B 7782857 14ACXS042-230A TXV 39,000 14.00 11.50 C33-36B SLP98UH070XV36B 7782858 14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C EL180UH090E60C 7782867 14ACXS042-230A TXV 39,000 14.50 12.20 C33-36C EL180UH110E60C 7627260 14ACXS042-230A TXV 39,000 14.50 12.20 C33-36C EL180UH110XE60C 7782868 14ACXS042-230A TXV 39,000 14.50 12.20 C33-36C EL195UH090XE48C 7782865 14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C EL195UH110XE60C 7782866 14ACXS042-230A TXV 39,000 14.50 12.20 C33-36C EL296UH090XE48C 7627254 14ACXS042-230A TXV 39,000 14.50 12.00 C33-36C EL296UH090XV36C 7627234 14ACXS042-230A TXV 39,000 14.50 12.20 C33-36C EL296UH090XV48C 7627237 14ACXS042-230A TXV 39,500 14.50 12.00 C33-36C EL296UH090XV60C 7627240 14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C EL296UH110XE60C 7627257 14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C EL296UH110XV60C 7627243 14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C SL280UH090V60C 7627246 14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C SL280UH090XV60C 7627248 14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C SL280UH110V60C 7782864 14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C SL280UH110XV60C 7627251 14ACXS042-230A TXV 39,000 14.50 12.00 C33-36C SLP98UH090XV36C 7782860 14ACXS042-230A TXV 39,000 14.50 12.20 C33-36C SLP98UH090XV48C 7782861 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 107 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 39,500 14.50 12.00 C33-36C SLP98UH090XV60C 7782862 14ACXS042-230A TXV 39,500 14.50 12.20 C33-36C SLP98UH110XV60C 7782863 14ACXS042-230A TXV 41,000 15.10 12.50 C33-38B EL180UH090E48B 7627273 14ACXS042-230A TXV 41,000 15.10 12.50 C33-38B EL180UH090XE48B 7782872 14ACXS042-230A TXV 40,500 14.50 12.20 C33-38B EL296UH045XV36B 7627276 14ACXS042-230A TXV 40,500 14.50 12.20 C33-38B EL296UH070XV36B 7627267 14ACXS042-230A TXV 41,000 15.10 12.50 C33-38B SL280UH090V36B 7782870 14ACXS042-230A TXV 41,000 15.10 12.50 C33-38B SL280UH090V48B 7627270 14ACXS042-230A TXV 41,000 15.10 12.50 C33-38B SL280UH090XV48B 7782871 14ACXS042-230A TXV 40,500 14.50 12.20 C33-38B SLP98UH070XV36B 7782869 14ACXS042-230A TXV 40,500 14.25 12.00 C33-38B 7627264 14ACXS042-230A TXV 39,500 14.50 12.20 C33-42 EL180UH090E48B 7782876 14ACXS042-230A TXV 39,500 14.50 12.20 C33-42 EL180UH090XE48B 7627288 14ACXS042-230A TXV 39,000 14.00 11.50 C33-42 EL296UH045XV36B 7782873 14ACXS042-230A TXV 39,000 14.00 11.50 C33-42 EL296UH070XV36B 7782874 14ACXS042-230A TXV 39,500 14.50 12.20 C33-42 SL280UH090V36B 7627282 14ACXS042-230A TXV 39,500 14.50 12.20 C33-42 SL280UH090V48B 7782875 14ACXS042-230A TXV 39,500 14.50 12.20 C33-42 SL280UH090XV48B 7627285 14ACXS042-230A TXV 39,000 14.00 11.50 C33-42 SLP98UH070XV36B 7627279 14ACXS042-230A TXV 41,500 15.50 12.50 C33-43B EL180UH090E48B 7627300 14ACXS042-230A TXV 41,500 15.50 12.50 C33-43B EL180UH090XE48B 7782881 14ACXS042-230A TXV 41,000 14.50 12.20 C33-43B EL296UH045XV36B 7627291 14ACXS042-230A TXV 41,000 14.50 12.20 C33-43B EL296UH070XV36B 7627294 14ACXS042-230A TXV 41,000 15.10 12.50 C33-43B SL280UH090V36B 7782879 14ACXS042-230A TXV 41,500 15.10 12.50 C33-43B SL280UH090V48B 7627297 14ACXS042-230A TXV 41,500 15.10 12.50 C33-43B SL280UH090XV48B 7782880 14ACXS042-230A TXV 41,000 14.50 12.20 C33-43B SLP98UH070XV36B 7782878 14ACXS042-230A TXV 41,000 14.25 12.00 C33-43B 7782877 14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C EL180UH090E60C 7627324 14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C EL180UH110E60C 7782889 14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C EL180UH110XE60C 7627327 14ACXS042-230A TXV 41,000 15.50 12.50 C33-43C EL195UH090XE48C 7782890 14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C EL195UH110XE60C 7782891 14ACXS042-230A TXV 41,000 15.50 12.50 C33-43C EL296UH090XE48C 7627330 14ACXS042-230A TXV 41,000 15.10 12.50 C33-43C EL296UH090XV36C 7627306 14ACXS042-230A TXV 41,000 15.10 12.50 C33-43C EL296UH090XV48C 7627309 14ACXS042-230A TXV 41,500 15.10 12.50 C33-43C EL296UH090XV60C 7782885 14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C EL296UH110XE60C 7627333 14ACXS042-230A TXV 41,500 15.10 12.50 C33-43C EL296UH110XV48C 7782884 14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C EL296UH110XV60C 7782886 14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C SL280UH090V60C 7627318 14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C SL280UH090XV60C 7782887 14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C SL280UH110V60C 7627321 14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C SL280UH110XV60C 7782888 14ACXS042-230A TXV 41,000 15.10 12.50 C33-43C SLP98UH090XV36C 7782882 14ACXS042-230A TXV 41,000 15.10 12.50 C33-43C SLP98UH090XV48C 7782883 14ACXS042-230A TXV 41,500 15.10 12.50 C33-43C SLP98UH090XV60C 7627312 14ACXS042-230A TXV 41,500 15.50 12.50 C33-43C SLP98UH110XV60C 7627315 14ACXS042-230A TXV 41,000 14.25 12.00 C33-43C 7627303 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 108 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 40,500 15.10 12.50 C33-48B EL180UH090E48B 7782894 14ACXS042-230A TXV 40,500 15.10 12.50 C33-48B EL180UH090XE48B 7627342 14ACXS042-230A TXV 40,500 14.50 12.20 C33-48B EL296UH045XV36B 7627336 14ACXS042-230A TXV 40,000 14.50 12.00 C33-48B EL296UH070XV36B 7627339 14ACXS042-230A TXV 40,500 15.00 12.50 C33-48B SL280UH090V36B 7782895 14ACXS042-230A TXV 40,500 15.00 12.50 C33-48B SL280UH090V48B 7627345 14ACXS042-230A TXV 40,500 15.00 12.50 C33-48B SL280UH090XV48B 7782896 14ACXS042-230A TXV 40,000 14.50 12.00 C33-48B SLP98UH070XV36B 7782893 14ACXS042-230A TXV 40,000 14.00 11.50 C33-48B 7782892 14ACXS042-230A TXV 41,000 15.10 12.50 C33-48C EL180UH090E60C 7782897 14ACXS042-230A TXV 40,500 15.10 12.50 C33-48C EL180UH110E60C 7627352 14ACXS042-230A TXV 40,500 15.10 12.50 C33-48C EL180UH110XE60C 7782898 14ACXS042-230A TXV 40,500 15.10 12.50 C33-48C EL195UH090XE48C 7627355 14ACXS042-230A TXV 41,000 15.10 12.50 C33-48C EL195UH110XE60C 7782899 14ACXS042-230A TXV 40,500 15.10 12.50 C33-48C EL296UH090XE48C 7627358 14ACXS042-230A TXV 40,500 15.00 12.50 C33-48C EL296UH090XV36C 7782900 14ACXS042-230A TXV 40,500 15.10 12.50 C33-48C EL296UH090XV48C 7627361 14ACXS042-230A TXV 41,000 15.00 12.50 C33-48C EL296UH090XV60C 7782901 14ACXS042-230A TXV 41,000 15.10 12.50 C33-48C EL296UH110XE60C 7627364 14ACXS042-230A TXV 40,500 15.10 12.50 C33-48C EL296UH110XV48C 7782902 14ACXS042-230A TXV 40,500 15.10 12.50 C33-48C EL296UH110XV60C 7627367 14ACXS042-230A TXV 41,000 15.10 12.50 C33-48C SL280UH090V60C 7782903 14ACXS042-230A TXV 41,000 15.10 12.50 C33-48C SL280UH090XV60C 7627370 14ACXS042-230A TXV 40,500 15.00 12.50 C33-48C SL280UH110V60C 7782904 14ACXS042-230A TXV 40,500 15.00 12.50 C33-48C SL280UH110XV60C 7627373 14ACXS042-230A TXV 40,500 15.00 12.50 C33-48C SLP98UH090XV36C 7627376 14ACXS042-230A TXV 40,500 15.10 12.50 C33-48C SLP98UH090XV48C 7782906 14ACXS042-230A TXV 41,000 15.00 12.50 C33-48C SLP98UH090XV60C 7782905 14ACXS042-230A TXV 40,500 15.10 12.50 C33-48C SLP98UH110XV60C 7627379 14ACXS042-230A TXV 40,000 14.00 11.50 C33-48C 7627349 14ACXS042-230A TXV 42,000 16.00 13.00 C33-49 EL180UH090E60C 7783122 14ACXS042-230A TXV 42,000 16.00 13.00 C33-49 EL180UH110E60C 7628176 14ACXS042-230A TXV 42,000 16.00 13.00 C33-49 EL180UH110XE60C 7783123 14ACXS042-230A TXV 41,500 15.50 12.50 C33-49 EL195UH090XE48C 7628179 14ACXS042-230A TXV 42,000 15.50 12.50 C33-49 EL195UH110XE60C 7783124 14ACXS042-230A TXV 41,500 15.50 12.50 C33-49 EL296UH090XE48C 7628183 14ACXS042-230A TXV 41,500 15.50 12.50 C33-49 EL296UH090XV36C 7628186 14ACXS042-230A TXV 41,500 15.50 12.50 C33-49 EL296UH090XV48C 7628188 14ACXS042-230A TXV 42,000 15.50 12.50 C33-49 EL296UH090XV60C 7628191 14ACXS042-230A TXV 42,000 15.50 12.50 C33-49 EL296UH110XE60C 7628194 14ACXS042-230A TXV 42,000 15.50 12.50 C33-49 EL296UH110XV48C 7783126 14ACXS042-230A TXV 42,000 15.50 12.50 C33-49 EL296UH110XV60C 7628197 14ACXS042-230A TXV 42,000 16.00 13.00 C33-49 SL280UH090V60C 7783127 14ACXS042-230A TXV 42,000 16.00 13.00 C33-49 SL280UH090XV60C 7628200 14ACXS042-230A TXV 42,000 15.50 12.50 C33-49 SL280UH110V60C 7783128 14ACXS042-230A TXV 42,000 15.50 12.50 C33-49 SL280UH110XV60C 7628203 14ACXS042-230A TXV 41,500 15.50 12.50 C33-49 SLP98UH090XV36C 7783129 14ACXS042-230A TXV 41,500 15.50 12.50 C33-49 SLP98UH090XV48C 7783130 14ACXS042-230A TXV 42,000 15.50 12.50 C33-49 SLP98UH090XV60C 7628208 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 109 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 42,000 15.50 12.50 C33-49 SLP98UH110XV60C 7783131 14ACXS042-230A TXV 41,500 14.25 12.20 C33-49 7628173 14ACXS042-230A TXV 41,000 15.50 12.50 C33-50/60C EL180UH090E60C 7627382 14ACXS042-230A TXV 41,000 15.50 12.50 C33-50/60C EL180UH110E60C 7782908 14ACXS042-230A TXV 41,000 15.50 12.50 C33-50/60C EL180UH110XE60C 7627385 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C EL195UH090XE48C 7782909 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C EL195UH110XE60C 7627388 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH090XE48C 7782910 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH090XV36C 7627391 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH090XV48C 7782911 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH090XV60C 7627394 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH110XE60C 7782912 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH110XV48C 7627397 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH110XV60C 7782913 14ACXS042-230A TXV 41,500 15.10 12.50 C33-50/60C SL280UH090V60C 7627400 14ACXS042-230A TXV 41,500 15.10 12.50 C33-50/60C SL280UH090XV60C 7782914 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C SL280UH110V60C 7627403 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C SL280UH110XV60C 7782915 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C SLP98UH090XV36C 7627406 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C SLP98UH090XV48C 7782916 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C SLP98UH090XV60C 7627409 14ACXS042-230A TXV 41,000 15.10 12.50 C33-50/60C SLP98UH110XV60C 7782917 14ACXS042-230A TXV 40,500 14.25 12.00 C33-50/60C 7782907 14ACXS042-230A TXV 42,000 16.00 13.00 C33-60D EL180UH135E60D 7782918 14ACXS042-230A TXV 42,000 15.50 12.50 C33-60D EL195UH135XE60D 7627415 14ACXS042-230A TXV 42,000 15.50 12.50 C33-60D EL296UH135XE60D 7782919 14ACXS042-230A TXV 42,000 16.00 13.00 C33-60D SL280UH135V60D 7627418 14ACXS042-230A TXV 41,000 14.25 12.00 C33-60D 7627412 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL180UH090E60C 7782921 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL180UH110E60C 7627424 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL180UH110XE60C 7782922 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL195UH090XE48C 7627427 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL195UH110XE60C 7782923 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH090XE48C 7627430 14ACXS042-230A TXV 42,000 15.50 12.50 C33-62C EL296UH090XV36C 7782924 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH090XV48C 7627433 14ACXS042-230A TXV 42,000 15.50 12.50 C33-62C EL296UH090XV60C 7782925 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH110XE60C 7627436 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH110XV48C 7782926 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH110XV60C 7627439 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C SL280UH090V60C 7782927 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C SL280UH090XV60C 7627442 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C SL280UH110V60C 7782928 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C SL280UH110XV60C 7627446 14ACXS042-230A TXV 42,000 15.50 12.50 C33-62C SLP98UH090XV36C 7782929 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C SLP98UH090XV48C 7627449 14ACXS042-230A TXV 42,000 15.50 12.50 C33-62C SLP98UH090XV60C 7782930 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62C SLP98UH110XV60C 7627452 14ACXS042-230A TXV 42,000 14.25 12.20 C33-62C 7627421 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 110 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62D EL180UH135E60D 7627455 14ACXS042-230A TXV 42,000 15.50 12.50 C33-62D EL195UH135XE60D 7782932 14ACXS042-230A TXV 42,000 15.50 12.50 C33-62D EL296UH135XE60D 7627458 14ACXS042-230A TXV 42,000 16.00 13.00 C33-62D SL280UH135V60D 7782933 14ACXS042-230A TXV 41,500 14.25 12.20 C33-62D 7782931 14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36B EL180UH090E48B 8258241 14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36B EL180UH090XE48B 8258236 14ACXS042-230A TXV 39,000 14.00 11.50 C35-30/36B EL296UH045XV36B 8258233 14ACXS042-230A TXV 39,000 14.00 11.50 C35-30/36B EL296UH070XV36B 8258234 14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36B SL280UH090V36B 8258243 14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36B SL280UH090V48B 8258231 14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36B SL280UH090XV48B 8258238 14ACXS042-230A TXV 39,000 14.00 11.50 C35-30/36B SLP98UH070XV36B 8258239 14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36C EL180UH090E60C 8258254 14ACXS042-230A TXV 39,000 14.50 12.20 C35-30/36C EL180UH110E60C 8258264 14ACXS042-230A TXV 39,000 14.50 12.20 C35-30/36C EL180UH110XE60C 8258256 14ACXS042-230A TXV 39,000 14.50 12.20 C35-30/36C EL195UH090XE48C 8258251 14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36C EL195UH110XE60C 8258253 14ACXS042-230A TXV 39,000 14.50 12.20 C35-30/36C EL296UH090XE48C 8258274 14ACXS042-230A TXV 39,000 14.50 12.00 C35-30/36C EL296UH090XV36C 8258245 14ACXS042-230A TXV 39,000 14.50 12.20 C35-30/36C EL296UH090XV48C 8258246 14ACXS042-230A TXV 39,500 14.50 12.00 C35-30/36C EL296UH090XV60C 8258266 14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36C EL296UH110XE60C 8258263 14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36C EL296UH110XV60C 8258268 14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36C SL280UH090V60C 8258269 14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36C SL280UH090XV60C 8258271 14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36C SL280UH110V60C 8258249 14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36C SL280UH110XV60C 8258273 14ACXS042-230A TXV 39,000 14.50 12.00 C35-30/36C SLP98UH090XV36C 8258258 14ACXS042-230A TXV 39,000 14.50 12.20 C35-30/36C SLP98UH090XV48C 8258259 14ACXS042-230A TXV 39,500 14.50 12.00 C35-30/36C SLP98UH090XV60C 8258261 14ACXS042-230A TXV 39,500 14.50 12.20 C35-30/36C SLP98UH110XV60C 8258248 14ACXS042-230A TXV 41,000 15.10 12.50 C35-36B EL180UH090E48B 8258288 14ACXS042-230A TXV 41,000 15.10 12.50 C35-36B EL180UH090XE48B 8258283 14ACXS042-230A TXV 40,500 14.50 12.20 C35-36B EL296UH045XV36B 8258290 14ACXS042-230A TXV 40,500 14.50 12.20 C35-36B EL296UH070XV36B 8258285 14ACXS042-230A TXV 41,000 15.10 12.50 C35-36B SL280UH090V36B 8258279 14ACXS042-230A TXV 41,000 15.10 12.50 C35-36B SL280UH090V48B 8258286 14ACXS042-230A TXV 41,000 15.10 12.50 C35-36B SL280UH090XV48B 8258281 14ACXS042-230A TXV 40,500 14.50 12.20 C35-36B SLP98UH070XV36B 8258278 14ACXS042-230A TXV 40,500 14.25 12.00 C35-36B 8258276 14ACXS042-230A TXV 41,500 15.50 12.50 C35-48B EL180UH090E48B 8258301 14ACXS042-230A TXV 41,500 15.50 12.50 C35-48B EL180UH090XE48B 8258298 14ACXS042-230A TXV 41,000 14.50 12.20 C35-48B EL296UH045XV36B 8258303 14ACXS042-230A TXV 41,000 14.50 12.20 C35-48B EL296UH070XV36B 8258305 14ACXS042-230A TXV 41,000 15.10 12.50 C35-48B SL280UH090V36B 8258295 14ACXS042-230A TXV 41,500 15.10 12.50 C35-48B SL280UH090V48B 8258300 14ACXS042-230A TXV 41,500 15.10 12.50 C35-48B SL280UH090XV48B 8258296 14ACXS042-230A TXV 41,000 14.50 12.20 C35-48B SLP98UH070XV36B 8258293 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 111 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 41,000 14.25 12.00 C35-48B 8258291 14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C EL180UH090E60C 8258328 14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C EL180UH110E60C 8258310 14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C EL180UH110XE60C 8258330 14ACXS042-230A TXV 41,000 15.50 12.50 C35-48C EL195UH090XE48C 8258311 14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C EL195UH110XE60C 8258313 14ACXS042-230A TXV 41,000 15.50 12.50 C35-48C EL296UH090XE48C 8258331 14ACXS042-230A TXV 41,000 15.10 12.50 C35-48C EL296UH090XV36C 8258335 14ACXS042-230A TXV 41,000 15.10 12.50 C35-48C EL296UH090XV48C 8258336 14ACXS042-230A TXV 41,500 15.10 12.50 C35-48C EL296UH090XV60C 8258320 14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C EL296UH110XE60C 8258333 14ACXS042-230A TXV 41,500 15.10 12.50 C35-48C EL296UH110XV48C 8258318 14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C EL296UH110XV60C 8258321 14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C SL280UH090V60C 8258325 14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C SL280UH090XV60C 8258323 14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C SL280UH110V60C 8258326 14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C SL280UH110XV60C 8258308 14ACXS042-230A TXV 41,000 15.10 12.50 C35-48C SLP98UH090XV36C 8258315 14ACXS042-230A TXV 41,000 15.10 12.50 C35-48C SLP98UH090XV48C 8258317 14ACXS042-230A TXV 41,500 15.10 12.50 C35-48C SLP98UH090XV60C 8258338 14ACXS042-230A TXV 41,500 15.50 12.50 C35-48C SLP98UH110XV60C 8258340 14ACXS042-230A TXV 41,000 14.25 12.00 C35-48C 8258307 14ACXS042-230A TXV 42,000 16.00 13.00 C35-49C EL180UH090E60C 8258355 14ACXS042-230A TXV 42,000 16.00 13.00 C35-49C EL180UH110E60C 8258367 14ACXS042-230A TXV 42,000 16.00 13.00 C35-49C EL180UH110XE60C 8258356 14ACXS042-230A TXV 41,500 15.50 12.50 C35-49C EL195UH090XE48C 8258368 14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C EL195UH110XE60C 8258345 14ACXS042-230A TXV 41,500 15.50 12.50 C35-49C EL296UH090XE48C 8258370 14ACXS042-230A TXV 41,500 15.50 12.50 C35-49C EL296UH090XV36C 8258372 14ACXS042-230A TXV 41,500 15.50 12.50 C35-49C EL296UH090XV48C 8258373 14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C EL296UH090XV60C 8258375 14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C EL296UH110XE60C 8258358 14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C EL296UH110XV48C 8258346 14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C EL296UH110XV60C 8258360 14ACXS042-230A TXV 42,000 16.00 13.00 C35-49C SL280UH090V60C 8258348 14ACXS042-230A TXV 42,000 16.00 13.00 C35-49C SL280UH090XV60C 8258362 14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C SL280UH110V60C 8258350 14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C SL280UH110XV60C 8258363 14ACXS042-230A TXV 41,500 15.50 12.50 C35-49C SLP98UH090XV36C 8258351 14ACXS042-230A TXV 41,500 15.50 12.50 C35-49C SLP98UH090XV48C 8258353 14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C SLP98UH090XV60C 8258365 14ACXS042-230A TXV 42,000 15.50 12.50 C35-49C SLP98UH110XV60C 8258343 14ACXS042-230A TXV 41,500 14.25 12.20 C35-49C 8258341 14ACXS042-230A TXV 41,000 15.50 12.50 C35-50/60C EL180UH090E60C 8258404 14ACXS042-230A TXV 41,000 15.50 12.50 C35-50/60C EL180UH110E60C 8258385 14ACXS042-230A TXV 41,000 15.50 12.50 C35-50/60C EL180UH110XE60C 8258406 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL195UH090XE48C 8258387 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL195UH110XE60C 8258408 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH090XE48C 8258388 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 112 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH090XV36C 8258409 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH090XV48C 8258390 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH090XV60C 8258394 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH110XE60C 8258391 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH110XV48C 8258396 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH110XV60C 8258393 14ACXS042-230A TXV 41,500 15.10 12.50 C35-50/60C SL280UH090V60C 8258397 14ACXS042-230A TXV 41,500 15.10 12.50 C35-50/60C SL280UH090XV60C 8258378 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C SL280UH110V60C 8258399 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C SL280UH110XV60C 8258380 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C SLP98UH090XV36C 8258401 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C SLP98UH090XV48C 8258382 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C SLP98UH090XV60C 8258403 14ACXS042-230A TXV 41,000 15.10 12.50 C35-50/60C SLP98UH110XV60C 8258383 14ACXS042-230A TXV 40,500 14.25 12.00 C35-50/60C 8258377 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL180UH090E60C 8258419 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL180UH110E60C 8258439 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL180UH110XE60C 8258421 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL195UH090XE48C 8258441 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL195UH110XE60C 8258423 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH090XE48C 8258443 14ACXS042-230A TXV 42,000 15.50 12.50 C35-60C EL296UH090XV36C 8258424 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH090XV48C 8258444 14ACXS042-230A TXV 42,000 15.50 12.50 C35-60C EL296UH090XV60C 8258426 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH110XE60C 8258429 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH110XV48C 8258428 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH110XV60C 8258431 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C SL280UH090V60C 8258413 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C SL280UH090XV60C 8258432 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C SL280UH110V60C 8258414 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C SL280UH110XV60C 8258434 14ACXS042-230A TXV 42,000 15.50 12.50 C35-60C SLP98UH090XV36C 8258416 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C SLP98UH090XV48C 8258436 14ACXS042-230A TXV 42,000 15.50 12.50 C35-60C SLP98UH090XV60C 8258418 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60C SLP98UH110XV60C 8258438 14ACXS042-230A TXV 42,000 14.25 12.20 C35-60C 8258411 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60D EL180UH135E60D 8258451 14ACXS042-230A TXV 42,000 15.50 12.50 C35-60D EL195UH135XE60D 8258448 14ACXS042-230A TXV 42,000 15.50 12.50 C35-60D EL296UH135XE60D 8258452 14ACXS042-230A TXV 42,000 16.00 13.00 C35-60D SL280UH135V60D 8258449 14ACXS042-230A TXV 41,500 14.25 12.20 C35-60D 8258446 14ACXS042-230A TXV 41,500 15.50 12.50 CBA27UHE-042 10259393 14ACXS042-230A TXV 41,500 15.50 12.50 CBA27UHE-048 10259394 14ACXS042-230A TXV 41,500 14.00 12.20 CBX25UH-042 7627464 14ACXS042-230A TXV 42,000 14.50 12.50 CBX25UH-048 7782935 14ACXS042-230A TXV 42,000 15.10 12.50 CBX25UHV-042 7627467 14ACXS042-230A TXV 42,000 15.50 12.50 CBX25UHV-048 7782936 14ACXS042-230A TXV 41,500 15.50 12.50 CBX27UH-042 7627461 14ACXS042-230A TXV 42,000 15.10 12.50 CBX27UH-048 7782934 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 113 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 40,500 14.00 12.20 CBX32M-042 7627470 14ACXS042-230A TXV 41,500 14.25 12.20 CBX32M-048 7627472 14ACXS042-230A TXV 42,000 15.10 12.50 CBX32MV-048 7627475 14ACXS042-230A TXV 42,000 15.00 12.50 CBX40UHV-042 7627477 14ACXS042-230A TXV 42,000 15.00 12.50 CBX40UHV-048 7782937 14ACXS042-230A TXV 40,500 15.10 12.50 CH23-51 EL180UH090E60C 7627480 14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 EL180UH110E60C 7782938 14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 EL180UH110XE60C 7627483 14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 EL296UH090XV48C 7782939 14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 EL296UH090XV60C 7627487 14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 EL296UH110XV48C 7627489 14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 EL296UH110XV60C 7627492 14ACXS042-230A TXV 40,500 15.10 12.50 CH23-51 SL280UH090V60C 7627494 14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 SL280UH110V60C 7782940 14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 SL280UH110XV60C 7782941 14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 SLP98UH090XV48C 7627498 14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 SLP98UH090XV60C 7782942 14ACXS042-230A TXV 40,000 15.10 12.50 CH23-51 SLP98UH110XV60C 7627501 14ACXS042-230A TXV 40,500 15.50 12.50 CH23-65 EL180UH090E60C 7782943 14ACXS042-230A TXV 40,500 15.50 12.50 CH23-65 EL180UH110E60C 7627504 14ACXS042-230A TXV 40,500 15.50 12.50 CH23-65 EL180UH110XE60C 7782944 14ACXS042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH090XV48C 7782945 14ACXS042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH090XV60C 7627509 14ACXS042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH110XV48C 7782946 14ACXS042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH110XV60C 7627512 14ACXS042-230A TXV 41,000 15.50 12.50 CH23-65 SL280UH090V60C 7782947 14ACXS042-230A TXV 40,500 15.50 12.50 CH23-65 SL280UH110V60C 7627515 14ACXS042-230A TXV 40,500 15.50 12.50 CH23-65 SL280UH110XV60C 7782948 14ACXS042-230A TXV 40,500 15.10 12.50 CH23-65 SLP98UH090XV48C 7627518 14ACXS042-230A TXV 40,500 15.10 12.50 CH23-65 SLP98UH090XV60C 7782949 14ACXS042-230A TXV 40,500 15.10 12.50 CH23-65 SLP98UH110XV60C 7627521 14ACXS042-230A TXV 40,500 15.10 12.50 CH33-42B EL180UH090E48B 7782950 14ACXS042-230A TXV 40,500 15.10 12.50 CH33-42B EL180UH090XE48B 7627524 14ACXS042-230A TXV 40,000 14.50 12.00 CH33-42B EL296UH070XV36B 7782951 14ACXS042-230A TXV 40,500 15.00 12.50 CH33-42B SL280UH090V36B 7627527 14ACXS042-230A TXV 40,500 15.00 12.50 CH33-42B SL280UH090V48B 7782952 14ACXS042-230A TXV 40,500 15.00 12.50 CH33-42B SL280UH090XV48B 7627530 14ACXS042-230A TXV 40,000 14.50 12.00 CH33-42B SLP98UH070XV36B 7782953 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-43B EL180UH090E48B 8565949 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-43B EL180UH090XE48B 8565950 14ACXS042-230A TXV 41,500 15.00 12.50 CH33-43B EL296UH045XV36B 7627533 14ACXS042-230A TXV 41,500 15.00 12.50 CH33-43B EL296UH070XV36B 7627536 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-43B SL280UH090V36B 7782955 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-43B SL280UH090V48B 7627539 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-43B SL280UH090XV48B 7782956 14ACXS042-230A TXV 41,500 15.00 12.50 CH33-43B SLP98UH070XV36B 7782954 14ACXS042-230A TXV 41,500 14.00 12.20 CH33-43B 8452497 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL180UH090E60C 7627545 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL180UH110E60C 7782958 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 114 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL180UH110XE60C 7627548 14ACXS042-230A TXV 41,000 15.50 12.50 CH33-43C EL195UH090XE48C 7782959 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL195UH110XE60C 7627551 14ACXS042-230A TXV 41,000 15.50 12.50 CH33-43C EL296UH090XE48C 7782960 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH090XV36C 7627554 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH090XV48C 7782961 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH090XV60C 7627557 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH110XE60C 7782962 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH110XV48C 7627560 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH110XV60C 7782963 14ACXS042-230A TXV 42,000 16.00 13.00 CH33-43C SL280UH090V60C 7627563 14ACXS042-230A TXV 42,000 16.00 13.00 CH33-43C SL280UH090XV60C 7782964 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C SL280UH110V60C 7627566 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C SL280UH110XV60C 7782965 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH090XV36C 7627569 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH090XV48C 7782966 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH090XV60C 7627572 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH110XV60C 7782967 14ACXS042-230A TXV 41,500 14.00 12.20 CH33-43C 7782957 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-44/48B EL180UH090E48B 7627575 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-44/48B EL180UH090XE48B 7782968 14ACXS042-230A TXV 40,500 14.50 12.20 CH33-44/48B EL296UH070XV36B 7627578 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-44/48B SL280UH090V36B 7782969 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-44/48B SL280UH090V48B 7627581 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-44/48B SL280UH090XV48B 7782970 14ACXS042-230A TXV 40,500 14.50 12.20 CH33-44/48B SLP98UH070XV36B 9150353 14ACXS042-230A TXV 41,000 15.00 12.50 CH33-48 EL180UH090E48B 8552650 14ACXS042-230A TXV 41,000 15.50 12.50 CH33-48C EL180UH090E60C 7782971 14ACXS042-230A TXV 41,000 15.50 12.50 CH33-48C EL180UH110E60C 7627587 14ACXS042-230A TXV 41,000 15.50 12.50 CH33-48C EL180UH110XE60C 7782972 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C EL195UH090XE48C 7627590 14ACXS042-230A TXV 41,500 15.10 12.50 CH33-48C EL195UH110XE60C 7782973 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH090XE48C 7627593 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH090XV36C 7782974 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH090XV48C 7627596 14ACXS042-230A TXV 41,500 15.10 12.50 CH33-48C EL296UH090XV60C 7782975 14ACXS042-230A TXV 41,500 15.10 12.50 CH33-48C EL296UH110XE60C 7627599 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH110XV48C 7782976 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH110XV60C 7627602 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-48C SL280UH090V60C 7782977 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-48C SL280UH090XV60C 7627605 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C SL280UH110V60C 7782978 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C SL280UH110XV60C 7627608 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C SLP98UH090XV36C 7782979 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C SLP98UH090XV48C 7627611 14ACXS042-230A TXV 41,500 15.10 12.50 CH33-48C SLP98UH090XV60C 7782980 14ACXS042-230A TXV 41,000 15.10 12.50 CH33-48C SLP98UH110XV60C 7627615 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL180UH090E60C 7782982 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL180UH110E60C 7627621 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 115 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL180UH110XE60C 7782983 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-49 EL195UH090XE48C 7627624 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL195UH110XE60C 7782984 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-49 EL296UH090XE48C 7627628 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-49 EL296UH090XV36C 7782985 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH090XV48C 7627631 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH090XV60C 7782986 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH110XE60C 7627634 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH110XV48C 7782987 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH110XV60C 7627637 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 SL280UH090V60C 7782988 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 SL280UH090XV60C 7627640 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 SL280UH110V60C 7782989 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 SL280UH110XV60C 7627644 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-49 SLP98UH090XV36C 7782990 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 SLP98UH090XV48C 7627647 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 SLP98UH090XV60C 7782991 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-49 SLP98UH110XV60C 7627650 14ACXS042-230A TXV 42,000 14.00 12.20 CH33-49 7627618 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL180UH090E60C 7782993 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL180UH110E60C 7627658 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL180UH110XE60C 7627661 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL195UH090XE48C 7627663 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-50/60C EL195UH110XE60C 7627666 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL296UH090XE48C 7627669 14ACXS042-230A TXV 41,500 15.10 12.50 CH33-50/60C EL296UH090XV36C 7627672 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL296UH090XV48C 7782994 14ACXS042-230A TXV 42,000 15.10 12.50 CH33-50/60C EL296UH090XV60C 7627675 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-50/60C EL296UH110XE60C 7782995 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL296UH110XV48C 7627678 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL296UH110XV60C 7782996 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-50/60C SL280UH090V60C 7627681 14ACXS042-230A TXV 42,000 15.50 12.50 CH33-50/60C SL280UH090XV60C 7782997 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-50/60C SL280UH110V60C 7627684 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-50/60C SL280UH110XV60C 7782998 14ACXS042-230A TXV 41,500 15.10 12.50 CH33-50/60C SLP98UH090XV36C 7627688 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-50/60C SLP98UH090XV48C 7782999 14ACXS042-230A TXV 42,000 15.10 12.50 CH33-50/60C SLP98UH090XV60C 7627691 14ACXS042-230A TXV 41,500 15.50 12.50 CH33-50/60C SLP98UH110XV60C 7783000 14ACXS042-230A TXV 41,500 14.00 12.20 CH33-50/60C 7627654 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-42B EL180UH090E48B 7627694 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-42B EL180UH090XE48B 7783001 14ACXS042-230A TXV 42,000 15.10 12.50 CH35-42B EL296UH045XV36B 7627697 14ACXS042-230A TXV 41,500 15.00 12.50 CH35-42B EL296UH070XV36B 7783002 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-42B SL280UH090V36B 7627700 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-42B SL280UH090V48B 7783003 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-42B SL280UH090XV48B 7627704 14ACXS042-230A TXV 41,500 15.00 12.50 CH35-42B SLP98UH070XV36B 7783004 14ACXS042-230A TXV 41,500 14.25 12.00 CH35-42B 8341995 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 116 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C EL180UH090E60C 7783005 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C EL180UH110E60C 7627710 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C EL180UH110XE60C 7783006 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C EL195UH090XE48C 7627713 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-42C EL195UH110XE60C 7783007 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C EL296UH090XE48C 7627716 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C EL296UH090XV36C 7783008 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C EL296UH090XV48C 7627719 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-42C EL296UH090XV60C 7783009 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-42C EL296UH110XE60C 7627722 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C EL296UH110XV48C 7783010 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C EL296UH110XV60C 7627725 14ACXS042-230A TXV 42,000 16.00 13.00 CH35-42C SL280UH090V60C 7783011 14ACXS042-230A TXV 42,000 16.00 13.00 CH35-42C SL280UH090XV60C 7627728 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C SL280UH110V60C 7783012 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C SL280UH110XV60C 7627731 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C SLP98UH090XV36C 7783013 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C SLP98UH090XV48C 7627734 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-42C SLP98UH090XV60C 7783014 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-42C SLP98UH110XV60C 7627737 14ACXS042-230A TXV 41,500 14.00 12.20 CH35-42C 7627707 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48B EL180UH090E48B 7783015 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48B EL180UH090XE48B 7627740 14ACXS042-230A TXV 41,000 14.50 12.20 CH35-48B EL296UH045XV36B 7783016 14ACXS042-230A TXV 41,000 14.50 12.20 CH35-48B EL296UH070XV36B 7627743 14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48B SL280UH090V36B 7783017 14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48B SL280UH090V48B 7627746 14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48B SL280UH090XV48B 7783018 14ACXS042-230A TXV 41,000 14.50 12.20 CH35-48B SLP98UH070XV36B 7627749 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48C EL180UH090E60C 7627752 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48C EL180UH110E60C 7783020 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48C EL180UH110XE60C 7627755 14ACXS042-230A TXV 41,000 15.10 12.50 CH35-48C EL195UH090XE48C 7783021 14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C EL195UH110XE60C 7627758 14ACXS042-230A TXV 41,000 15.10 12.50 CH35-48C EL296UH090XE48C 7783023 14ACXS042-230A TXV 41,000 15.10 12.50 CH35-48C EL296UH090XV36C 7627761 14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C EL296UH090XV48C 7783024 14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C EL296UH090XV60C 7627764 14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C EL296UH110XE60C 7783025 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48C EL296UH110XV48C 7627767 14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C EL296UH110XV60C 7783026 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48C SL280UH090V60C 7627770 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-48C SL280UH090XV60C 7783027 14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C SL280UH110V60C 7627773 14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C SL280UH110XV60C 7783028 14ACXS042-230A TXV 41,000 15.10 12.50 CH35-48C SLP98UH090XV36C 7627776 14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C SLP98UH090XV48C 7783029 14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C SLP98UH090XV60C 7627779 14ACXS042-230A TXV 41,500 15.10 12.50 CH35-48C SLP98UH110XV60C 7783030 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 117 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 41,500 14.00 12.20 CH35-48C 7783019 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL180UH090E60C 7783031 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL180UH110E60C 7627786 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL180UH110XE60C 7783032 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-51C EL195UH090XE48C 7627789 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL195UH110XE60C 7783033 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-51C EL296UH090XE48C 7627792 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-51C EL296UH090XV36C 7783034 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL296UH090XV48C 7627795 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL296UH090XV60C 7783035 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL296UH110XE60C 7627798 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL296UH110XV48C 7783036 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C EL296UH110XV60C 7627801 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C SL280UH090V60C 7783037 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C SL280UH090XV60C 7627804 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C SL280UH110V60C 7783038 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C SL280UH110XV60C 7627807 14ACXS042-230A TXV 41,500 15.50 12.50 CH35-51C SLP98UH090XV36C 7783039 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C SLP98UH090XV48C 7627810 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C SLP98UH090XV60C 7783040 14ACXS042-230A TXV 42,000 15.50 12.50 CH35-51C SLP98UH110XV60C 7627813 14ACXS042-230A TXV 42,000 14.00 12.20 CH35-51C 7627783 14ACXS042-230A TXV 40,500 15.10 12.50 CR33-48 EL180DF110E60C 7627816 14ACXS042-230A TXV 40,500 15.10 12.50 CR33-48 EL195DF090XE48C 7783042 14ACXS042-230A TXV 40,500 15.10 12.50 CR33-48 EL195DF110XE60C 7627819 14ACXS042-230A TXV 40,500 15.10 12.50 CR33-48 EL296DF090XE48C 7783044 14ACXS042-230A TXV 40,500 15.00 12.20 CR33-48 EL296DF090XV60C 7627822 14ACXS042-230A TXV 40,500 15.10 12.50 CR33-48 EL296DF110XE60C 7783045 14ACXS042-230A TXV 40,500 15.10 12.50 CR33-48 SL280DF090V60C 7627825 14ACXS042-230A TXV 40,500 15.10 12.50 CR33-48 SL280DF110V60C 7783046 14ACXS042-230A TXV 40,500 15.00 12.20 CR33-48 SLP98DF090XV60C 7783047 14ACXS042-230A TXV 40,500 14.50 12.20 CR33-48B SL280DF090V48B 7783041 14ACXS042-230A TXV 41,500 15.50 12.50 CR33-50/60 EL180DF110E60C 7627831 14ACXS042-230A TXV 41,000 15.10 12.50 CR33-50/60 EL195DF090XE48C 7783048 14ACXS042-230A TXV 41,500 15.50 12.50 CR33-50/60 EL195DF110XE60C 7627834 14ACXS042-230A TXV 41,000 15.10 12.50 CR33-50/60 EL296DF090XE48C 7783049 14ACXS042-230A TXV 41,500 15.10 12.50 CR33-50/60 EL296DF090XV60C 7627837 14ACXS042-230A TXV 41,500 15.50 12.50 CR33-50/60 EL296DF110XE60C 7783050 14ACXS042-230A TXV 41,500 15.50 12.50 CR33-50/60 EL296DF110XV60C 7627840 14ACXS042-230A TXV 41,000 15.50 12.50 CR33-50/60 SL280DF090V60C 7783051 14ACXS042-230A TXV 41,500 15.50 12.50 CR33-50/60 SL280DF110V60C 7627843 14ACXS042-230A TXV 41,000 15.10 12.50 CR33-50/60 SLP98DF090XV36C 7783052 14ACXS042-230A TXV 41,000 15.10 12.50 CR33-50/60 SLP98DF090XV48C 7627846 14ACXS042-230A TXV 41,500 15.10 12.50 CR33-50/60 SLP98DF090XV60C 7783053 14ACXS042-230A TXV 41,500 15.50 12.50 CR33-50/60 SLP98DF110XV60C 7627849 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-36B EL180UH090E48B 7627862 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-36B EL180UH090XE48B 7627864 14ACXS042-230A TXV 39,000 14.00 11.50 CX34-36B EL296UH045XV36B 7627855 14ACXS042-230A TXV 39,000 14.00 11.50 CX34-36B EL296UH070XV36B 7627859 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 118 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-36B SL280UH090V36B 7783054 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-36B SL280UH090V48B 7627852 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-36B SL280UH090XV48B 7783055 14ACXS042-230A TXV 39,000 14.00 11.50 CX34-36B SLP98UH070XV36B 7783056 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-36C EL180UH090E60C 7627867 14ACXS042-230A TXV 39,000 14.50 12.20 CX34-36C EL180UH110E60C 7627870 14ACXS042-230A TXV 39,000 14.50 12.20 CX34-36C EL180UH110XE60C 7627872 14ACXS042-230A TXV 39,000 14.50 12.20 CX34-36C EL195UH090XE48C 7627875 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-36C EL195UH110XE60C 7627877 14ACXS042-230A TXV 39,000 14.50 12.20 CX34-36C EL296UH090XE48C 7783057 14ACXS042-230A TXV 39,000 14.50 12.00 CX34-36C EL296UH090XV36C 7783058 14ACXS042-230A TXV 39,000 14.50 12.20 CX34-36C EL296UH090XV48C 7627881 14ACXS042-230A TXV 39,500 14.50 12.00 CX34-36C EL296UH090XV60C 7783059 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-36C EL296UH110XE60C 7627884 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-36C EL296UH110XV60C 7783060 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-36C SL280UH090V60C 7627887 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-36C SL280UH090XV60C 7783061 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-36C SL280UH110V60C 7627890 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-36C SL280UH110XV60C 7783062 14ACXS042-230A TXV 39,000 14.50 12.00 CX34-36C SLP98UH090XV36C 7627893 14ACXS042-230A TXV 39,000 14.50 12.20 CX34-36C SLP98UH090XV48C 7783063 14ACXS042-230A TXV 39,500 14.50 12.00 CX34-36C SLP98UH090XV60C 7627896 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-36C SLP98UH110XV60C 7783064 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-38B EL180UH090E48B 7783065 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-38B EL180UH090XE48B 7627902 14ACXS042-230A TXV 40,500 14.50 12.20 CX34-38B EL296UH045XV36B 7627905 14ACXS042-230A TXV 40,500 14.50 12.20 CX34-38B EL296UH070XV36B 7627907 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-38B SL280UH090V36B 7783066 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-38B SL280UH090V48B 7627911 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-38B SL280UH090XV48B 7627913 14ACXS042-230A TXV 40,500 14.50 12.20 CX34-38B SLP98UH070XV36B 7627916 14ACXS042-230A TXV 40,500 14.25 12.00 CX34-38B 7627899 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-42 EL180UH090E48B 7627919 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-42 EL180UH090XE48B 7627921 14ACXS042-230A TXV 39,000 14.00 11.50 CX34-42 EL296UH045XV36B 7627924 14ACXS042-230A TXV 39,000 14.00 11.50 CX34-42 EL296UH070XV36B 7627927 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-42 SL280UH090V36B 7627929 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-42 SL280UH090V48B 7627932 14ACXS042-230A TXV 39,500 14.50 12.20 CX34-42 SL280UH090XV48B 7627935 14ACXS042-230A TXV 39,000 14.00 11.50 CX34-42 SLP98UH070XV36B 7627937 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43B EL180UH090E48B 7783067 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43B EL180UH090XE48B 7627943 14ACXS042-230A TXV 41,000 14.50 12.20 CX34-43B EL296UH045XV36B 7627946 14ACXS042-230A TXV 41,000 14.50 12.20 CX34-43B EL296UH070XV36B 7627948 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-43B SL280UH090V36B 7627951 14ACXS042-230A TXV 41,500 15.10 12.50 CX34-43B SL280UH090V48B 7627954 14ACXS042-230A TXV 41,500 15.10 12.50 CX34-43B SL280UH090XV48B 7627955 14ACXS042-230A TXV 41,000 14.50 12.20 CX34-43B SLP98UH070XV36B 7783068 14ACXS042-230A TXV 41,000 14.25 12.00 CX34-43B 7627940 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 119 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C EL180UH090E60C 7783069 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C EL180UH110E60C 7627961 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C EL180UH110XE60C 7783070 14ACXS042-230A TXV 41,000 15.50 12.50 CX34-43C EL195UH090XE48C 7627964 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C EL195UH110XE60C 7783071 14ACXS042-230A TXV 41,000 15.50 12.50 CX34-43C EL296UH090XE48C 7627967 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-43C EL296UH090XV36C 7627970 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-43C EL296UH090XV48C 7627973 14ACXS042-230A TXV 41,500 15.10 12.50 CX34-43C EL296UH090XV60C 7783072 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C EL296UH110XE60C 7627976 14ACXS042-230A TXV 41,500 15.10 12.50 CX34-43C EL296UH110XV48C 7783073 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C EL296UH110XV60C 7627979 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C SL280UH090V60C 7783074 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C SL280UH090XV60C 7627982 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C SL280UH110V60C 7783075 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C SL280UH110XV60C 7627985 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-43C SLP98UH090XV36C 7783076 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-43C SLP98UH090XV48C 7627988 14ACXS042-230A TXV 41,500 15.10 12.50 CX34-43C SLP98UH090XV60C 7783077 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-43C SLP98UH110XV60C 7627991 14ACXS042-230A TXV 41,000 14.25 12.00 CX34-43C 7627958 14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48B EL180UH090E48B 7627994 14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48B EL180UH090XE48B 7783079 14ACXS042-230A TXV 40,500 14.50 12.20 CX34-44/48B EL296UH045XV36B 7627997 14ACXS042-230A TXV 40,000 14.50 12.00 CX34-44/48B EL296UH070XV36B 7783080 14ACXS042-230A TXV 40,500 15.00 12.50 CX34-44/48B SL280UH090V36B 7628000 14ACXS042-230A TXV 40,500 15.00 12.50 CX34-44/48B SL280UH090V48B 7783081 14ACXS042-230A TXV 40,500 15.00 12.50 CX34-44/48B SL280UH090XV48B 7628003 14ACXS042-230A TXV 40,000 14.50 12.00 CX34-44/48B SLP98UH070XV36B 7783082 14ACXS042-230A TXV 40,000 14.00 11.50 CX34-44/48B 7783078 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-44/48C EL180UH090E60C 7783083 14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL180UH110E60C 7628009 14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL180UH110XE60C 7783084 14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL195UH090XE48C 7628012 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-44/48C EL195UH110XE60C 7628015 14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH090XE48C 7783085 14ACXS042-230A TXV 40,500 15.00 12.50 CX34-44/48C EL296UH090XV36C 7628018 14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH090XV48C 7783087 14ACXS042-230A TXV 41,000 15.00 12.50 CX34-44/48C EL296UH090XV60C 7628021 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-44/48C EL296UH110XE60C 7783086 14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH110XV48C 7783088 14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH110XV60C 7628024 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-44/48C SL280UH090V60C 7783089 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-44/48C SL280UH090XV60C 7628027 14ACXS042-230A TXV 40,500 15.00 12.50 CX34-44/48C SL280UH110V60C 7783090 14ACXS042-230A TXV 40,500 15.00 12.50 CX34-44/48C SL280UH110XV60C 7628030 14ACXS042-230A TXV 40,500 15.00 12.50 CX34-44/48C SLP98UH090XV36C 7783091 14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C SLP98UH090XV48C 7628033 14ACXS042-230A TXV 41,000 15.00 12.50 CX34-44/48C SLP98UH090XV60C 7783092 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 120 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 40,500 15.10 12.50 CX34-44/48C SLP98UH110XV60C 7628036 14ACXS042-230A TXV 40,000 14.00 11.50 CX34-44/48C 7628006 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-49 EL180UH090E60C 7628039 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-49 EL180UH110E60C 7783094 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-49 EL180UH110XE60C 7628043 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-49 EL195UH090XE48C 7783095 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-49 EL195UH110XE60C 7628046 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-49 EL296UH090XE48C 7783096 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-49 EL296UH090XV36C 7628049 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-49 EL296UH090XV48C 7783097 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-49 EL296UH090XV60C 7628052 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-49 EL296UH110XE60C 7628053 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-49 EL296UH110XV48C 7783098 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-49 EL296UH110XV60C 7628056 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-49 SL280UH090V60C 7783099 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-49 SL280UH090XV60C 7628060 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-49 SL280UH110V60C 7628063 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-49 SL280UH110XV60C 7628066 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-49 SLP98UH090XV36C 7628067 14ACXS042-230A TXV 41,500 15.50 12.50 CX34-49 SLP98UH090XV48C 7783100 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-49 SLP98UH090XV60C 7628071 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-49 SLP98UH110XV60C 7628074 14ACXS042-230A TXV 41,500 14.25 12.20 CX34-49 7783093 14ACXS042-230A TXV 41,000 15.50 12.50 CX34-50/60C EL180UH090E60C 7628080 14ACXS042-230A TXV 41,000 15.50 12.50 CX34-50/60C EL180UH110E60C 7628083 14ACXS042-230A TXV 41,000 15.50 12.50 CX34-50/60C EL180UH110XE60C 7628085 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL195UH090XE48C 7628087 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL195UH110XE60C 7783101 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH090XE48C 7628091 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH090XV36C 7628094 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH090XV48C 7628097 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH090XV60C 7628100 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH110XE60C 7628102 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH110XV48C 7628105 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH110XV60C 7628108 14ACXS042-230A TXV 41,500 15.10 12.50 CX34-50/60C SL280UH090V60C 7783102 14ACXS042-230A TXV 41,500 15.10 12.50 CX34-50/60C SL280UH090XV60C 7628111 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C SL280UH110V60C 7783103 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C SL280UH110XV60C 7628114 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C SLP98UH090XV36C 7783104 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C SLP98UH090XV48C 7628118 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C SLP98UH090XV60C 7783105 14ACXS042-230A TXV 41,000 15.10 12.50 CX34-50/60C SLP98UH110XV60C 7628121 14ACXS042-230A TXV 40,500 14.25 12.00 CX34-50/60C 7628077 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-60D EL180UH135E60D 7628124 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-60D EL195UH135XE60D 7783107 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-60D EL296UH135XE60D 7628127 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-60D SL280UH135V60D 7783108 14ACXS042-230A TXV 41,000 14.25 12.00 CX34-60D 7783106 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 121 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C EL180UH090E60C 7783109 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C EL180UH110E60C 7628134 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C EL180UH110XE60C 7783110 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C EL195UH090XE48C 7628137 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C EL195UH110XE60C 7783111 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C EL296UH090XE48C 7628140 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-62C EL296UH090XV36C 7783112 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C EL296UH090XV48C 7628144 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-62C EL296UH090XV60C 7783113 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C EL296UH110XE60C 7628147 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C EL296UH110XV60C 7783114 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C SL280UH090V60C 7628150 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C SL280UH090XV60C 7783115 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C SL280UH110V60C 7628153 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C SL280UH110XV60C 7783116 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-62C SLP98UH090XV36C 7628156 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C SLP98UH090XV48C 7783117 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-62C SLP98UH090XV60C 7628160 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62C SLP98UH110XV60C 7783118 14ACXS042-230A TXV 42,000 14.25 12.20 CX34-62C 7628131 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62D EL180UH135E60D 7783119 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-62D EL195UH135XE60D 7628166 14ACXS042-230A TXV 42,000 15.50 12.50 CX34-62D EL296UH135XE60D 7783120 14ACXS042-230A TXV 42,000 16.00 13.00 CX34-62D SL280UH135V60D 7628169 14ACXS042-230A TXV 41,500 14.50 12.20 CX34-62D 7628163 14ACXS042-230A TXV 39,500 14.50 12.20 CX35-30/36B EL180UH090E48B 8258464 14ACXS042-230A TXV 39,500 14.50 12.20 CX35-30/36B EL180UH090XE48B 8258466 14ACXS042-230A TXV 39,000 14.00 11.50 CX35-30/36B EL296UH045XV36B 8258461 14ACXS042-230A TXV 39,000 14.00 11.50 CX35-30/36B EL296UH070XV36B 8258462 14ACXS042-230A TXV 39,500 14.50 12.20 CX35-30/36B SL280UH090V36B 8258454 14ACXS042-230A TXV 39,500 14.50 12.20 CX35-30/36B SL280UH090V48B 8258459 14ACXS042-230A TXV 39,500 14.50 12.20 CX35-30/36B SL280UH090XV48B 8258456 14ACXS042-230A TXV 39,000 14.00 11.50 CX35-30/36B SLP98UH070XV36B 8258457 14ACXS042-230A TXV 39,500 14.50 12.20 CX35-30/36C EL180UH090E60C 8258498 14ACXS042-230A TXV 39,000 14.50 12.20 CX35-30/36C EL180UH110E60C 8258488 14ACXS042-230A TXV 39,000 14.50 12.20 CX35-30/36C EL180UH110XE60C 8258490 14ACXS042-230A TXV 39,000 14.50 12.20 CX35-30/36C EL195UH090XE48C 8258491 14ACXS042-230A TXV 39,500 14.50 12.20 CX35-30/36C EL195UH110XE60C 8258493 14ACXS042-230A TXV 39,000 14.50 12.20 CX35-30/36C EL296UH090XE48C 8258475 14ACXS042-230A TXV 39,000 14.50 12.00 CX35-30/36C EL296UH090XV36C 8258477 14ACXS042-230A TXV 39,000 14.50 12.20 CX35-30/36C EL296UH090XV48C 8258495 14ACXS042-230A TXV 39,500 14.50 12.00 CX35-30/36C EL296UH090XV60C 8258479 14ACXS042-230A TXV 39,500 14.50 12.20 CX35-30/36C EL296UH110XE60C 8258496 14ACXS042-230A TXV 39,500 14.50 12.20 CX35-30/36C EL296UH110XV60C 8258467 14ACXS042-230A TXV 39,500 14.50 12.20 CX35-30/36C SL280UH090V60C 8258480 14ACXS042-230A TXV 39,500 14.50 12.20 CX35-30/36C SL280UH090XV60C 8258469 14ACXS042-230A TXV 39,500 14.50 12.20 CX35-30/36C SL280UH110V60C 8258483 14ACXS042-230A TXV 39,500 14.50 12.20 CX35-30/36C SL280UH110XV60C 8258470 14ACXS042-230A TXV 39,000 14.50 12.00 CX35-30/36C SLP98UH090XV36C 8258485 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 122 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 39,000 14.50 12.20 CX35-30/36C SLP98UH090XV48C 8258472 14ACXS042-230A TXV 39,500 14.50 12.00 CX35-30/36C SLP98UH090XV60C 8258486 14ACXS042-230A TXV 39,500 14.50 12.20 CX35-30/36C SLP98UH110XV60C 8258474 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-36B EL180UH090E48B 8258503 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-36B EL180UH090XE48B 8258511 14ACXS042-230A TXV 40,500 14.50 12.20 CX35-36B EL296UH045XV36B 8258513 14ACXS042-230A TXV 40,500 14.50 12.20 CX35-36B EL296UH070XV36B 8258504 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-36B SL280UH090V36B 8258501 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-36B SL280UH090V48B 8258506 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-36B SL280UH090XV48B 8258508 14ACXS042-230A TXV 40,500 14.50 12.20 CX35-36B SLP98UH070XV36B 8258509 14ACXS042-230A TXV 40,500 14.25 12.00 CX35-36B 8258500 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48B EL180UH090E48B 8258516 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48B EL180UH090XE48B 8258520 14ACXS042-230A TXV 41,000 14.50 12.20 CX35-48B EL296UH045XV36B 8258521 14ACXS042-230A TXV 41,000 14.50 12.20 CX35-48B EL296UH070XV36B 8258523 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-48B SL280UH090V36B 8258525 14ACXS042-230A TXV 41,500 15.10 12.50 CX35-48B SL280UH090V48B 8258527 14ACXS042-230A TXV 41,500 15.10 12.50 CX35-48B SL280UH090XV48B 8258528 14ACXS042-230A TXV 41,000 14.50 12.20 CX35-48B SLP98UH070XV36B 8258518 14ACXS042-230A TXV 41,000 14.25 12.00 CX35-48B 8258514 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C EL180UH090E60C 8258542 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C EL180UH110E60C 8258556 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C EL180UH110XE60C 8258543 14ACXS042-230A TXV 41,000 15.50 12.50 CX35-48C EL195UH090XE48C 8258557 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C EL195UH110XE60C 8258545 14ACXS042-230A TXV 41,000 15.50 12.50 CX35-48C EL296UH090XE48C 8258559 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-48C EL296UH090XV36C 8258561 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-48C EL296UH090XV48C 8258562 14ACXS042-230A TXV 41,500 15.10 12.50 CX35-48C EL296UH090XV60C 8258532 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C EL296UH110XE60C 8258564 14ACXS042-230A TXV 41,500 15.10 12.50 CX35-48C EL296UH110XV48C 8258533 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C EL296UH110XV60C 8258547 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C SL280UH090V60C 8258535 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C SL280UH090XV60C 8258549 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C SL280UH110V60C 8258537 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C SL280UH110XV60C 8258550 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-48C SLP98UH090XV36C 8258539 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-48C SLP98UH090XV48C 8258552 14ACXS042-230A TXV 41,500 15.10 12.50 CX35-48C SLP98UH090XV60C 8258540 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-48C SLP98UH110XV60C 8258554 14ACXS042-230A TXV 41,000 14.25 12.00 CX35-48C 8258530 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-49C EL180UH090E60C 8258592 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-49C EL180UH110E60C 8258572 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-49C EL180UH110XE60C 8258594 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-49C EL195UH090XE48C 8258574 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C EL195UH110XE60C 8258596 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-49C EL296UH090XE48C 8258576 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-49C EL296UH090XV36C 8258597 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 123 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-49C EL296UH090XV48C 8258577 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C EL296UH090XV60C 8258599 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C EL296UH110XE60C 8258582 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C EL296UH110XV48C 8258568 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C EL296UH110XV60C 8258584 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-49C SL280UH090V60C 8258569 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-49C SL280UH090XV60C 8258586 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C SL280UH110V60C 8258587 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C SL280UH110XV60C 8258589 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-49C SLP98UH090XV36C 8258591 14ACXS042-230A TXV 41,500 15.50 12.50 CX35-49C SLP98UH090XV48C 8258571 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C SLP98UH090XV60C 8258579 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-49C SLP98UH110XV60C 8258581 14ACXS042-230A TXV 41,500 14.25 12.20 CX35-49C 8258566 14ACXS042-230A TXV 41,000 15.00 12.50 CX35-50/60C EL180UH090E48B 10025832 14ACXS042-230A TXV 41,000 15.50 12.50 CX35-50/60C EL180UH090E60C 8258628 14ACXS042-230A TXV 41,000 15.50 12.50 CX35-50/60C EL180UH110E60C 8258629 14ACXS042-230A TXV 41,000 15.50 12.50 CX35-50/60C EL180UH110XE60C 8258631 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL195UH090XE48C 8258632 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL195UH110XE60C 8258605 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL296UH090XE48C 8258618 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL296UH090XV36C 8258620 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL296UH090XV48C 8258621 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL296UH090XV60C 8258623 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL296UH110XE60C 8258624 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL296UH110XV48C 8258626 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL296UH110XV60C 8258610 14ACXS042-230A TXV 41,500 15.10 12.50 CX35-50/60C SL280UH090V60C 8258607 14ACXS042-230A TXV 41,500 15.10 12.50 CX35-50/60C SL280UH090XV60C 8258612 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C SL280UH110V60C 8258609 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C SL280UH110XV60C 8258613 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C SLP98UH090XV36C 8258602 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C SLP98UH090XV48C 8258615 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C SLP98UH090XV60C 8258604 14ACXS042-230A TXV 41,000 15.10 12.50 CX35-50/60C SLP98UH110XV60C 8258616 14ACXS042-230A TXV 40,500 14.25 12.00 CX35-50/60C 8258601 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C EL180UH090E60C 8258649 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C EL180UH110E60C 8258659 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C EL180UH110XE60C 8258651 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C EL195UH090XE48C 8258660 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C EL195UH110XE60C 8258639 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C EL296UH090XE48C 8258662 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-60C EL296UH090XV36C 8258641 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C EL296UH090XV48C 8258664 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-60C EL296UH090XV60C 8258642 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C EL296UH110XE60C 8258666 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C EL296UH110XV60C 8258644 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C SL280UH090V60C 8258652 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C SL280UH090XV60C 8258646 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 124 AHRI SYSTEM MATCHES - NORTH / SOUTH REGION - S018-S024-S030-S036-S042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C SL280UH110V60C 8258654 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C SL280UH110XV60C 8258647 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-60C SLP98UH090XV36C 8258655 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C SLP98UH090XV48C 8258636 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-60C SLP98UH090XV60C 8258657 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60C SLP98UH110XV60C 8258637 14ACXS042-230A TXV 42,000 14.25 12.20 CX35-60C 8258634 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60D EL180UH135E60D 8258669 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-60D EL195UH135XE60D 8258672 14ACXS042-230A TXV 42,000 15.50 12.50 CX35-60D EL296UH135XE60D 8258671 14ACXS042-230A TXV 42,000 16.00 13.00 CX35-60D SL280UH135V60D 8258674 14ACXS042-230A TXV 41,500 14.50 12.20 CX35-60D 8258667 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 125 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-018-230A RFC 19,000 14.00 12.20 C33-31A 7186906 14ACX-018-230A RFC 19,000 14.00 12.20 C33-31B 7186910 14ACX-018-230A RFC 18,000 14.00 12.20 C35-18/24A 8471005 14ACX-018-230A RFC 18,000 14.00 12.20 C35-18/24B 8471006 14ACX-018-230A RFC 19,200 14.25 12.20 CH33-31A 7186942 14ACX-018-230A RFC 19,100 14.25 12.20 CH33-31B 7186946 14ACX-018-230A RFC 19,000 14.00 12.20 CR33-30/36A 7186983 14ACX-018-230A RFC 19,000 14.00 12.20 CR33-30/36B 7186986 14ACX-018-230A TXV 18,200 14.50 12.50 C33-18 EL180UH045E36A 7186877 14ACX-018-230A TXV 18,200 14.50 12.50 C33-18 EL180UH045XE36A 7186876 14ACX-018-230A TXV 19,500 16.00 13.00 C33-19 EL180UH045E36A 7186880 14ACX-018-230A TXV 19,500 16.00 13.00 C33-19 EL180UH045XE36A 7186879 14ACX-018-230A TXV 18,400 15.00 12.50 C33-24A EL180UH045E36A 7186882 14ACX-018-230A TXV 18,400 15.00 12.50 C33-24A EL180UH045XE36A 7186881 14ACX-018-230A TXV 18,500 14.50 12.20 C33-24B EL180UH070E36B 7186884 14ACX-018-230A TXV 18,500 14.50 12.20 C33-24B EL180UH070XE36B 7186883 14ACX-018-230A TXV 18,000 14.50 12.50 C33-24B EL195UH030XE24B 8608812 14ACX-018-230A TXV 18,000 14.50 12.50 C33-24B EL195UH045XE24B 8608813 14ACX-018-230A TXV 18,600 14.50 12.50 C33-24B EL195UH045XE36B 7186885 14ACX-018-230A TXV 18,600 14.50 12.50 C33-24B EL296UH045XE36B 7186886 14ACX-018-230A TXV 19,700 16.00 13.00 C33-25A EL180UH045E36A 7186890 14ACX-018-230A TXV 19,700 16.00 13.00 C33-25A EL180UH045XE36A 7186889 14ACX-018-230A TXV 19,200 14.25 12.20 C33-25A 7186888 14ACX-018-230A TXV 19,500 15.50 12.50 C33-25B EL180UH070E36B 7186894 14ACX-018-230A TXV 19,500 15.50 12.50 C33-25B EL180UH070XE36B 7186893 14ACX-018-230A TXV 18,000 15.50 12.50 C33-25B EL195UH030XE24B 8608814 14ACX-018-230A TXV 18,000 15.50 12.50 C33-25B EL195UH045XE24B 8608815 14ACX-018-230A TXV 20,000 16.00 13.00 C33-25B EL195UH045XE36B 7186895 14ACX-018-230A TXV 20,000 16.00 13.00 C33-25B EL296UH045XE36B 7186896 14ACX-018-230A TXV 20,200 16.00 13.00 C33-25B EL296UH045XV36B 7186897 14ACX-018-230A TXV 20,200 16.00 13.00 C33-25B EL296UH070XE36B 9113202 14ACX-018-230A TXV 20,200 16.00 13.00 C33-25B EL296UH070XV36B 7614659 14ACX-018-230A TXV 20,200 16.00 13.00 C33-25B SLP98UH070XV36B 7523952 14ACX-018-230A TXV 19,200 14.25 12.20 C33-25B 7186892 14ACX-018-230A TXV 19,100 15.50 12.50 C33-30A EL180UH045E36A 7186899 14ACX-018-230A TXV 19,100 15.50 12.50 C33-30A EL180UH045XE36A 7186900 14ACX-018-230A TXV 18,900 15.00 12.50 C33-30B EL180UH070E36B 7186901 14ACX-018-230A TXV 18,900 15.00 12.50 C33-30B EL180UH070XE36B 7186902 14ACX-018-230A TXV 18,000 15.10 12.50 C33-30B EL195UH030XE24B 8608816 14ACX-018-230A TXV 18,000 15.10 12.50 C33-30B EL195UH045XE24B 8608817 14ACX-018-230A TXV 18,900 15.10 12.50 C33-30B EL195UH045XE36B 7186903 14ACX-018-230A TXV 18,900 15.10 12.50 C33-30B EL296UH045XE36B 7186904 14ACX-018-230A TXV 19,500 16.00 13.00 C33-30B EL296UH045XV36B 7186905 14ACX-018-230A TXV 19,900 16.00 13.00 C33-31A EL180UH045E36A 7186908 14ACX-018-230A TXV 19,900 16.00 13.00 C33-31A EL180UH045XE36A 7186909 14ACX-018-230A TXV 19,300 14.50 12.20 C33-31A 7186907 14ACX-018-230A TXV 19,700 15.50 12.50 C33-31B EL180UH070E36B 7186912 14ACX-018-230A TXV 19,700 15.50 12.50 C33-31B EL180UH070XE36B 7186913 14ACX-018-230A TXV 18,000 16.00 13.00 C33-31B EL195UH030XE24B 8608818 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 126 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-018-230A TXV 18,000 16.00 13.00 C33-31B EL195UH045XE24B 8608819 14ACX-018-230A TXV 19,800 16.00 13.00 C33-31B EL195UH045XE36B 7186914 14ACX-018-230A TXV 19,800 16.00 13.00 C33-31B EL296UH045XE36B 7186915 14ACX-018-230A TXV 20,400 16.00 13.50 C33-31B EL296UH045XV36B 7186916 14ACX-018-230A TXV 20,400 16.00 13.50 C33-31B EL296UH070XV36B 7186917 14ACX-018-230A TXV 20,400 16.00 13.50 C33-31B SLP98UH070XV36B 7523953 14ACX-018-230A TXV 19,300 14.50 12.20 C33-31B 7186911 14ACX-018-230A TXV 19,700 16.00 13.00 C35-24A EL180UH045E36A 8267474 14ACX-018-230A TXV 19,700 16.00 13.00 C35-24A EL180UH045XE36A 8267473 14ACX-018-230A TXV 19,200 14.25 12.20 C35-24A 8267472 14ACX-018-230A TXV 19,500 15.50 12.50 C35-24B EL180UH070E36B 8267479 14ACX-018-230A TXV 19,500 15.50 12.50 C35-24B EL180UH070XE36B 8267478 14ACX-018-230A TXV 18,000 14.50 12.20 C35-24B EL195UH030XE24B 8608820 14ACX-018-230A TXV 18,000 14.50 12.20 C35-24B EL195UH045XE24B 8608821 14ACX-018-230A TXV 20,000 16.00 13.00 C35-24B EL195UH045XE36B 8267480 14ACX-018-230A TXV 20,000 16.00 13.00 C35-24B EL296UH045XE36B 8267481 14ACX-018-230A TXV 20,200 16.00 13.00 C35-24B EL296UH045XV36B 8267482 14ACX-018-230A TXV 20,200 16.00 13.00 C35-24B EL296UH070XV36B 8267476 14ACX-018-230A TXV 20,200 16.00 13.00 C35-24B SLP98UH070XV36B 8267477 14ACX-018-230A TXV 19,200 14.25 12.20 C35-24B 8267475 14ACX-018-230A TXV 19,900 16.00 13.00 C35-30A EL180UH045E36A 8267484 14ACX-018-230A TXV 19,900 16.00 13.00 C35-30A EL180UH045XE36A 8267485 14ACX-018-230A TXV 19,300 14.50 12.20 C35-30A 8267483 14ACX-018-230A TXV 19,700 15.50 12.50 C35-30B EL180UH070E36B 8267490 14ACX-018-230A TXV 19,700 15.50 12.50 C35-30B EL180UH070XE36B 8267491 14ACX-018-230A TXV 18,000 14.50 12.20 C35-30B EL195UH030XE24B 8608822 14ACX-018-230A TXV 18,000 14.50 12.20 C35-30B EL195UH045XE24B 8608823 14ACX-018-230A TXV 19,800 16.00 13.00 C35-30B EL195UH045XE36B 8267492 14ACX-018-230A TXV 19,800 16.00 13.00 C35-30B EL296UH045XE36B 8267493 14ACX-018-230A TXV 20,400 16.00 13.50 C35-30B EL296UH045XV36B 8267488 14ACX-018-230A TXV 20,400 16.00 13.50 C35-30B EL296UH070XV36B 8267489 14ACX-018-230A TXV 20,400 16.00 13.50 C35-30B SLP98UH070XV36B 8267487 14ACX-018-230A TXV 19,300 14.50 12.20 C35-30B 8267486 14ACX-018-230A TXV 19,400 16.00 13.00 CBA27UHE-018 10259477 14ACX-018-230A TXV 19,400 16.00 13.00 CBA27UHE-024 10259373 14ACX-018-230A TXV 19,000 15.50 12.50 CBX25UHV-018 7186920 14ACX-018-230A TXV 19,200 16.00 13.00 CBX25UHV-024 7186921 14ACX-018-230A TXV 19,700 16.00 13.00 CBX27UH-018 7186922 14ACX-018-230A TXV 19,700 16.00 13.00 CBX27UH-024 7186923 14ACX-018-230A TXV 19,100 14.50 12.20 CBX32M-018/024 7186924 14ACX-018-230A TXV 19,300 14.50 12.50 CBX32M-030 7186925 14ACX-018-230A TXV 19,600 16.00 13.00 CBX32MV-018/024 7186926 14ACX-018-230A TXV 19,700 16.00 13.00 CBX32MV-024/030 7186927 14ACX-018-230A TXV 19,900 16.00 13.00 CBX40UHV-024 7186928 14ACX-018-230A TXV 19,800 16.00 13.00 CBX40UHV-030 7186929 14ACX-018-230A TXV 19,400 16.00 13.00 CH33-19 EL180UH045E36A 7187234 14ACX-018-230A TXV 19,400 16.00 13.00 CH33-19 EL180UH045XE36A 7187233 14ACX-018-230A TXV 19,300 16.00 13.00 CH33-24/30 EL180UH045E36A 7187239 14ACX-018-230A TXV 19,300 16.00 13.00 CH33-24/30 EL180UH045XE36A 7187237 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 127 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-018-230A TXV 19,800 16.00 13.00 CH33-25A EL180UH045E36A 7186935 14ACX-018-230A TXV 19,800 16.00 13.00 CH33-25A EL180UH045XE36A 7186934 14ACX-018-230A TXV 19,200 14.50 12.20 CH33-25A 7186933 14ACX-018-230A TXV 19,400 15.50 12.50 CH33-25B EL180UH070E36B 7186938 14ACX-018-230A TXV 19,400 15.50 12.50 CH33-25B EL180UH070XE36B 7186937 14ACX-018-230A TXV 19,900 16.00 13.00 CH33-25B EL195UH045XE36B 7186939 14ACX-018-230A TXV 19,900 16.00 13.00 CH33-25B EL296UH045XE36B 7186940 14ACX-018-230A TXV 20,200 16.00 13.00 CH33-25B EL296UH045XV36B 7186941 14ACX-018-230A TXV 20,200 16.00 13.00 CH33-31A EL180UH045E36A 7186945 14ACX-018-230A TXV 20,200 16.00 13.00 CH33-31A EL180UH045XE36A 7186944 14ACX-018-230A TXV 19,500 14.50 12.20 CH33-31A 7186943 14ACX-018-230A TXV 19,900 16.00 13.00 CH33-31B EL180UH070E36B 7186949 14ACX-018-230A TXV 19,900 16.00 13.00 CH33-31B EL180UH070XE36B 7186948 14ACX-018-230A TXV 18,000 14.50 12.20 CH33-31B EL195UH030XE24B 8608824 14ACX-018-230A TXV 18,000 14.50 12.20 CH33-31B EL195UH045XE24B 8608825 14ACX-018-230A TXV 19,900 16.00 13.00 CH33-31B EL195UH045XE36B 7186950 14ACX-018-230A TXV 19,900 16.00 13.00 CH33-31B EL296UH045XE36B 7186951 14ACX-018-230A TXV 20,600 16.00 13.50 CH33-31B EL296UH045XV36B 7186952 14ACX-018-230A TXV 19,500 14.50 12.20 CH33-31B 7186947 14ACX-018-230A TXV 19,400 16.00 13.00 CH35-18A EL180UH045E36A 7186955 14ACX-018-230A TXV 19,400 16.00 13.00 CH35-18A EL180UH045XE36A 7186954 14ACX-018-230A TXV 19,900 16.00 13.00 CH35-24A EL180UH045E36A 7186958 14ACX-018-230A TXV 19,900 16.00 13.00 CH35-24A EL180UH045XE36A 7186959 14ACX-018-230A TXV 19,300 14.50 12.20 CH35-24A 7186957 14ACX-018-230A TXV 19,500 15.50 12.50 CH35-24B EL180UH070E36B 7186961 14ACX-018-230A TXV 19,500 15.50 12.50 CH35-24B EL180UH070XE36B 7186962 14ACX-018-230A TXV 19,600 15.50 12.50 CH35-24B EL195UH045XE36B 7186963 14ACX-018-230A TXV 19,600 15.50 12.50 CH35-24B EL296UH045XE36B 7186964 14ACX-018-230A TXV 20,200 16.00 13.00 CH35-24B EL296UH045XV36B 7186965 14ACX-018-230A TXV 20,200 16.00 13.00 CH35-30A EL180UH045E36A 7186969 14ACX-018-230A TXV 20,200 16.00 13.00 CH35-30A EL180UH045XE36A 7186968 14ACX-018-230A TXV 19,500 14.50 12.20 CH35-30A 7186967 14ACX-018-230A TXV 19,900 16.00 13.00 CH35-30B EL180UH070E36B 7186972 14ACX-018-230A TXV 19,900 16.00 13.00 CH35-30B EL180UH070XE36B 7186973 14ACX-018-230A TXV 18,000 14.50 12.20 CH35-30B EL195UH030XE24B 8608826 14ACX-018-230A TXV 18,000 14.50 12.20 CH35-30B EL195UH045XE24B 8608827 14ACX-018-230A TXV 19,900 16.00 13.00 CH35-30B EL195UH045XE36B 7186974 14ACX-018-230A TXV 19,900 16.00 13.00 CH35-30B EL296UH045XE36B 7186975 14ACX-018-230A TXV 20,600 16.00 13.50 CH35-30B EL296UH045XV36B 7186976 14ACX-018-230A TXV 19,500 14.50 12.20 CH35-30B 7186971 14ACX-018-230A TXV 19,200 15.50 12.50 CR33-18 EL180DF045E36A 7186978 14ACX-018-230A TXV 18,600 15.10 12.50 CR33-24A EL180DF045E36A 7186979 14ACX-018-230A TXV 18,600 14.50 12.50 CR33-24B EL180DF070E36B 7186980 14ACX-018-230A TXV 19,800 16.00 13.00 CR33-30/36A EL180DF045E36A 7186985 14ACX-018-230A TXV 19,400 14.50 12.20 CR33-30/36A 7186984 14ACX-018-230A TXV 19,800 15.50 12.50 CR33-30/36B EL180DF070E36B 7186988 14ACX-018-230A TXV 19,400 14.50 12.20 CR33-30/36B 7186987 14ACX-018-230A TXV 18,400 15.00 12.50 CX34-18/24A EL180UH045E36A 7186991 14ACX-018-230A TXV 18,400 15.00 12.50 CX34-18/24A EL180UH045XE36A 7186992 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 128 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-018-230A TXV 18,500 14.50 12.20 CX34-18/24B EL180UH070E36B 7186993 14ACX-018-230A TXV 18,500 14.50 12.20 CX34-18/24B EL180UH070XE36B 7186994 14ACX-018-230A TXV 18,000 14.50 12.50 CX34-18/24B EL195UH030XE24B 8608828 14ACX-018-230A TXV 18,000 14.50 12.50 CX34-18/24B EL195UH045XE24B 8608829 14ACX-018-230A TXV 18,600 14.50 12.50 CX34-18/24B EL195UH045XE36B 7186995 14ACX-018-230A TXV 18,600 14.50 12.50 CX34-18/24B EL296UH045XE36B 7186996 14ACX-018-230A TXV 19,500 16.00 13.00 CX34-19 EL180UH045E36A 7186999 14ACX-018-230A TXV 19,500 16.00 13.00 CX34-19 EL180UH045XE36A 7186998 14ACX-018-230A TXV 19,700 16.00 13.00 CX34-25A EL180UH045E36A 7187002 14ACX-018-230A TXV 19,700 16.00 13.00 CX34-25A EL180UH045XE36A 7187001 14ACX-018-230A TXV 19,200 14.25 12.20 CX34-25A 7187000 14ACX-018-230A TXV 19,500 15.50 12.50 CX34-25B EL180UH070E36B 7187005 14ACX-018-230A TXV 19,500 15.50 12.50 CX34-25B EL180UH070XE36B 7187004 14ACX-018-230A TXV 18,000 15.50 12.50 CX34-25B EL195UH030XE24B 8608830 14ACX-018-230A TXV 18,000 15.50 12.50 CX34-25B EL195UH045XE24B 8608831 14ACX-018-230A TXV 20,000 16.00 13.00 CX34-25B EL195UH045XE36B 7187006 14ACX-018-230A TXV 20,000 16.00 13.00 CX34-25B EL296UH045XE36B 7187007 14ACX-018-230A TXV 20,200 16.00 13.00 CX34-25B EL296UH045XV36B 7187008 14ACX-018-230A TXV 20,200 16.00 13.00 CX34-25B EL296UH070XE36B 9113203 14ACX-018-230A TXV 20,200 16.00 13.00 CX34-25B EL296UH070XV36B 7187009 14ACX-018-230A TXV 20,200 16.00 13.00 CX34-25B SLP98UH070XV36B 7523954 14ACX-018-230A TXV 19,200 14.25 12.20 CX34-25B 7187003 14ACX-018-230A TXV 19,100 15.50 12.50 CX34-30A EL180UH045E36A 7187010 14ACX-018-230A TXV 19,100 15.50 12.50 CX34-30A EL180UH045XE36A 7187011 14ACX-018-230A TXV 18,900 15.00 12.50 CX34-30B EL180UH070E36B 7187012 14ACX-018-230A TXV 18,900 15.00 12.50 CX34-30B EL180UH070XE36B 7187013 14ACX-018-230A TXV 18,000 15.10 12.50 CX34-30B EL195UH030XE24B 8608832 14ACX-018-230A TXV 18,000 15.10 12.50 CX34-30B EL195UH045XE24B 8608833 14ACX-018-230A TXV 18,900 15.10 12.50 CX34-30B EL195UH045XE36B 7187014 14ACX-018-230A TXV 18,900 15.10 12.50 CX34-30B EL296UH045XE36B 7187015 14ACX-018-230A TXV 19,500 16.00 13.00 CX34-30B EL296UH045XV36B 7187016 14ACX-018-230A TXV 19,900 16.00 13.00 CX34-31A EL180UH045E36A 7187018 14ACX-018-230A TXV 19,900 16.00 13.00 CX34-31A EL180UH045XE36A 7187019 14ACX-018-230A TXV 19,300 14.50 12.20 CX34-31A 7187017 14ACX-018-230A TXV 19,700 15.50 12.50 CX34-31B EL180UH070E36B 7187021 14ACX-018-230A TXV 19,700 15.50 12.50 CX34-31B EL180UH070XE36B 7187022 14ACX-018-230A TXV 18,000 16.00 13.00 CX34-31B EL195UH030XE24B 8608834 14ACX-018-230A TXV 18,000 16.00 13.00 CX34-31B EL195UH045XE24B 8608835 14ACX-018-230A TXV 19,800 16.00 13.00 CX34-31B EL195UH045XE36B 7187023 14ACX-018-230A TXV 19,800 16.00 13.00 CX34-31B EL296UH045XE36B 7187024 14ACX-018-230A TXV 20,400 16.00 13.50 CX34-31B EL296UH045XV36B 7187025 14ACX-018-230A TXV 20,400 16.00 13.50 CX34-31B EL296UH070XV36B 7187026 14ACX-018-230A TXV 20,400 16.00 13.50 CX34-31B SLP98UH070XV36B 7523955 14ACX-018-230A TXV 19,300 14.50 12.20 CX34-31B 7187020 14ACX-018-230A TXV 18,400 15.00 12.50 CX35-18/24A EL180UH045E36A 8267494 14ACX-018-230A TXV 18,400 15.00 12.50 CX35-18/24A EL180UH045XE36A 8267495 14ACX-018-230A TXV 18,500 14.50 12.20 CX35-18/24B EL180UH070E36B 8267499 14ACX-018-230A TXV 18,500 14.50 12.20 CX35-18/24B EL180UH070XE36B 8267496 14ACX-018-230A TXV 18,600 15.00 12.50 CX35-18/24B EL195UH045XE36B 8267497 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 129 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-018-230A TXV 18,600 15.00 12.50 CX35-18/24B EL296UH045XE36B 8267498 14ACX-018-230A TXV 19,700 16.00 13.00 CX35-24A EL180UH045E36A 8267501 14ACX-018-230A TXV 19,700 16.00 13.00 CX35-24A EL180UH045XE36A 8267502 14ACX-018-230A TXV 19,200 14.25 12.20 CX35-24A 8267500 14ACX-018-230A TXV 19,500 15.50 12.50 CX35-24B EL180UH070E36B 8267507 14ACX-018-230A TXV 19,500 15.50 12.50 CX35-24B EL180UH070XE36B 8267506 14ACX-018-230A TXV 18,000 14.50 12.20 CX35-24B EL195UH030XE24B 8608836 14ACX-018-230A TXV 18,000 14.50 12.20 CX35-24B EL195UH045XE24B 8608837 14ACX-018-230A TXV 20,000 16.00 13.00 CX35-24B EL195UH045XE36B 8267508 14ACX-018-230A TXV 20,000 16.00 13.00 CX35-24B EL296UH045XE36B 8267509 14ACX-018-230A TXV 20,200 16.00 13.00 CX35-24B EL296UH045XV36B 8267510 14ACX-018-230A TXV 20,200 16.00 13.00 CX35-24B EL296UH070XV36B 8267505 14ACX-018-230A TXV 20,200 16.00 13.00 CX35-24B SLP98UH070XV36B 8267504 14ACX-018-230A TXV 19,200 14.25 12.20 CX35-24B 8267503 14ACX-018-230A TXV 19,900 16.00 13.00 CX35-30A EL180UH045E36A 8267512 14ACX-018-230A TXV 19,900 16.00 13.00 CX35-30A EL180UH045XE36A 8267513 14ACX-018-230A TXV 19,300 14.50 12.20 CX35-30A 8267511 14ACX-018-230A TXV 19,700 15.50 12.50 CX35-30B EL180UH070E36B 8267520 14ACX-018-230A TXV 19,700 15.50 12.50 CX35-30B EL180UH070XE36B 8267521 14ACX-018-230A TXV 18,000 14.50 12.20 CX35-30B EL195UH030XE24B 8608838 14ACX-018-230A TXV 18,000 14.50 12.20 CX35-30B EL195UH045XE24B 8608839 14ACX-018-230A TXV 19,800 16.00 13.00 CX35-30B EL195UH045XE36B 8267516 14ACX-018-230A TXV 19,800 16.00 13.00 CX35-30B EL296UH045XE36B 8267517 14ACX-018-230A TXV 20,400 16.00 13.50 CX35-30B EL296UH045XV36B 8267518 14ACX-018-230A TXV 20,400 16.00 13.50 CX35-30B EL296UH070XV36B 8267519 14ACX-018-230A TXV 20,400 16.00 13.50 CX35-30B SLP98UH070XV36B 8267515 14ACX-018-230A TXV 19,300 14.50 12.20 CX35-30B 8267514 14ACX-024-230A RFC 24,000 14.20 12.20 C33-31A 7175358 14ACX-024-230A RFC 24,000 14.20 12.20 C33-31B 7175359 14ACX-024-230A RFC 24,000 14.50 12.50 C33-38A 7175363 14ACX-024-230A RFC 24,000 14.50 12.50 C33-38B 7175364 14ACX-024-230A RFC 23,400 14.00 12.20 C35-24A 8471007 14ACX-024-230A RFC 23,600 14.00 12.20 C35-30A 8471008 14ACX-024-230A RFC 23,600 14.00 12.20 C35-30B 8471010 14ACX-024-230A RFC 24,000 14.00 12.20 C35-36A 8471012 14ACX-024-230A RFC 24,000 14.00 12.20 C35-36B 8471014 14ACX-024-230A RFC 24,000 14.00 12.20 CH33-25A 7175368 14ACX-024-230A RFC 24,000 14.50 12.20 CH33-31A 7175370 14ACX-024-230A RFC 24,000 14.50 12.20 CH33-31B 7175371 14ACX-024-230A RFC 23,800 14.00 12.20 CH33-36C 7174712 14ACX-024-230A RFC 24,000 14.20 12.20 CH33-42B 7175388 14ACX-024-230A RFC 24,000 14.50 12.20 CH33-43B 7175389 14ACX-024-230A RFC 23,800 14.00 12.20 CH35-36A 7175413 14ACX-024-230A RFC 24,000 14.00 12.20 CH35-36C 7175407 14ACX-024-230A RFC 24,000 14.00 12.20 CR33-30/36A 7175391 14ACX-024-230A RFC 24,000 14.00 12.20 CR33-30/36B 7175392 14ACX-024-230A RFC 24,000 14.00 12.20 CR33-30/36C 7175373 14ACX-024-230A TXV 22,200 14.50 12.20 C33-18 EL180UH045E36A 7174491 14ACX-024-230A TXV 22,200 14.50 12.20 C33-18 EL180UH045XE36A 7174492 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 130 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-024-230A TXV 23,800 16.00 13.00 C33-19 EL180UH045E36A 7174497 14ACX-024-230A TXV 23,800 16.00 13.00 C33-19 EL180UH045XE36A 7174498 14ACX-024-230A TXV 24,000 16.00 13.00 C33-19 SL280UH070V36A 7174495 14ACX-024-230A TXV 24,000 16.00 13.00 C33-19 SL280UH070XV36A 7174496 14ACX-024-230A TXV 22,800 15.00 12.50 C33-24A EL180UH045E36A 7174501 14ACX-024-230A TXV 22,800 15.00 12.50 C33-24A EL180UH045XE36A 7174502 14ACX-024-230A TXV 23,200 15.10 12.50 C33-24A SL280UH070V36A 7174499 14ACX-024-230A TXV 23,200 15.10 12.50 C33-24A SL280UH070XV36A 7174500 14ACX-024-230A TXV 22,800 15.10 12.50 C33-24B EL180UH070E36B 7174508 14ACX-024-230A TXV 22,800 15.10 12.50 C33-24B EL180UH070XE36B 7174509 14ACX-024-230A TXV 22,800 14.50 12.20 C33-24B EL195UH030XE24B 8608840 14ACX-024-230A TXV 22,800 14.50 12.20 C33-24B EL195UH045XE24B 8608841 14ACX-024-230A TXV 22,600 15.00 12.50 C33-24B EL195UH045XE36B 7174510 14ACX-024-230A TXV 23,000 15.00 12.50 C33-24B EL195UH070XE36B 7174511 14ACX-024-230A TXV 22,600 15.00 12.50 C33-24B EL296UH045XE36B 7174512 14ACX-024-230A TXV 23,000 15.10 12.50 C33-24B EL296UH045XV36B 7174506 14ACX-024-230A TXV 23,000 15.10 12.50 C33-24B EL296UH070XE36B 7174513 14ACX-024-230A TXV 23,000 15.50 12.50 C33-24B EL296UH070XV36B 7174507 14ACX-024-230A TXV 23,200 15.10 12.50 C33-24B SL280UH090V36B 7174503 14ACX-024-230A TXV 23,200 15.10 12.50 C33-24B SL280UH090V48B 7174504 14ACX-024-230A TXV 23,200 15.10 12.50 C33-24B SL280UH090XV48B 7174505 14ACX-024-230A TXV 23,000 15.50 12.50 C33-24B SLP98UH070XV36B 7174514 14ACX-024-230A TXV 23,000 15.50 12.50 C33-24C EL296UH090XV36C 7174515 14ACX-024-230A TXV 23,000 15.50 12.50 C33-24C SLP98UH090XV36C 7174516 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25A EL180UH045E36A 7174520 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25A EL180UH045XE36A 7174521 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25A SL280UH070V36A 7174518 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25A SL280UH070XV36A 7174519 14ACX-024-230A TXV 23,800 14.25 12.20 C33-25A 7174517 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25B EL180UH070E36B 7174529 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25B EL180UH070XE36B 7174530 14ACX-024-230A TXV 24,000 15.50 12.50 C33-25B EL195UH030XE24B 8608842 14ACX-024-230A TXV 24,000 15.50 12.50 C33-25B EL195UH045XE24B 8608843 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25B EL195UH045XE36B 7174531 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25B EL195UH070XE36B 7174532 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25B EL296UH045XE36B 7174533 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25B EL296UH045XV36B 7174526 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25B EL296UH070XE36B 7174534 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25B EL296UH070XV36B 7174527 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25B SL280UH090V36B 7174523 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25B SL280UH090V48B 7174524 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25B SL280UH090XV48B 7174525 14ACX-024-230A TXV 24,000 16.00 13.00 C33-25B SLP98UH070XV36B 7174528 14ACX-024-230A TXV 23,800 14.25 12.20 C33-25B 7174522 14ACX-024-230A TXV 23,600 15.50 12.50 C33-30A EL180UH045E36A 7174540 14ACX-024-230A TXV 23,600 15.50 12.50 C33-30A EL180UH045XE36A 7174541 14ACX-024-230A TXV 23,600 15.10 12.50 C33-30A SL280UH070V36A 7174538 14ACX-024-230A TXV 23,600 15.10 12.50 C33-30A SL280UH070XV36A 7174539 14ACX-024-230A TXV 23,400 15.50 12.50 C33-30B EL180UH070E36B 7174545 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 131 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-024-230A TXV 23,400 15.50 12.50 C33-30B EL180UH070XE36B 7174546 14ACX-024-230A TXV 23,400 15.10 12.50 C33-30B EL195UH030XE24B 8608844 14ACX-024-230A TXV 23,400 15.10 12.50 C33-30B EL195UH045XE24B 8608845 14ACX-024-230A TXV 23,000 15.10 12.50 C33-30B EL195UH045XE36B 7174547 14ACX-024-230A TXV 23,400 15.50 12.50 C33-30B EL195UH070XE36B 7174548 14ACX-024-230A TXV 23,000 15.10 12.50 C33-30B EL296UH045XE36B 7174549 14ACX-024-230A TXV 23,600 15.50 12.50 C33-30B EL296UH045XV36B 7174551 14ACX-024-230A TXV 23,400 15.50 12.50 C33-30B EL296UH070XE36B 7174550 14ACX-024-230A TXV 23,600 15.50 12.50 C33-30B EL296UH070XV36B 7174552 14ACX-024-230A TXV 23,600 15.10 13.00 C33-30B SL280UH090V36B 7174542 14ACX-024-230A TXV 23,600 15.10 12.50 C33-30B SL280UH090V48B 7174543 14ACX-024-230A TXV 23,600 15.10 12.50 C33-30B SL280UH090XV48B 7174544 14ACX-024-230A TXV 23,600 15.50 12.50 C33-30B SLP98UH070XV36B 7174553 14ACX-024-230A TXV 23,600 16.00 13.00 C33-30C EL296UH090XV36C 7174554 14ACX-024-230A TXV 23,600 16.00 13.00 C33-30C SLP98UH090XV36C 7174555 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31A EL180UH045E36A 7174559 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31A EL180UH045XE36A 7174560 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31A SL280UH070V36A 7174557 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31A SL280UH070XV36A 7174558 14ACX-024-230A TXV 24,000 14.50 12.20 C33-31A 7174556 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31B EL180UH070E36B 7174565 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31B EL180UH070XE36B 7174566 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31B EL195UH030XE24B 8608846 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31B EL195UH045XE24B 8608847 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31B EL195UH045XE36B 7174567 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31B EL195UH070XE36B 7174568 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31B EL296UH045XE36B 7174569 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31B EL296UH045XV36B 7174571 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31B EL296UH070XE36B 7174570 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31B EL296UH070XV36B 7174572 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31B SL280UH090V36B 7174562 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31B SL280UH090V48B 7174563 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31B SL280UH090XV48B 7174564 14ACX-024-230A TXV 24,000 16.00 13.00 C33-31B SLP98UH070XV36B 7174573 14ACX-024-230A TXV 24,000 14.50 12.20 C33-31B 7174561 14ACX-024-230A TXV 24,000 16.00 13.00 C33-36A EL180UH045E36A 7174579 14ACX-024-230A TXV 24,000 16.00 13.00 C33-36A EL180UH045XE36A 7174580 14ACX-024-230A TXV 24,000 16.00 13.00 C33-36A SL280UH070V36A 7174577 14ACX-024-230A TXV 24,000 16.00 13.00 C33-36A SL280UH070XV36A 7174578 14ACX-024-230A TXV 24,000 16.00 13.00 C33-36B EL180UH070E36B 7174584 14ACX-024-230A TXV 24,000 16.00 13.00 C33-36B EL180UH070XE36B 7174585 14ACX-024-230A TXV 24,000 15.50 12.50 C33-36B EL195UH030XE24B 8608848 14ACX-024-230A TXV 24,000 15.50 12.50 C33-36B EL195UH045XE24B 8608849 14ACX-024-230A TXV 23,400 15.50 12.50 C33-36B EL195UH045XE36B 7174586 14ACX-024-230A TXV 23,600 15.50 13.00 C33-36B EL195UH070XE36B 7174587 14ACX-024-230A TXV 23,400 15.50 12.50 C33-36B EL296UH045XE36B 7174588 14ACX-024-230A TXV 24,000 16.00 13.00 C33-36B EL296UH045XV36B 7174590 14ACX-024-230A TXV 23,600 15.50 13.00 C33-36B EL296UH070XE36B 7174589 14ACX-024-230A TXV 24,000 16.00 13.00 C33-36B EL296UH070XV36B 7174591 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 132 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-024-230A TXV 24,000 16.00 13.00 C33-36B SL280UH090V36B 7174581 14ACX-024-230A TXV 24,000 16.00 13.00 C33-36B SL280UH090V48B 7174582 14ACX-024-230A TXV 24,000 16.00 13.00 C33-36B SL280UH090XV48B 7174583 14ACX-024-230A TXV 24,000 16.00 13.00 C33-36B SLP98UH070XV36B 7174592 14ACX-024-230A TXV 24,000 16.00 13.00 C33-36C EL296UH090XV36C 7174593 14ACX-024-230A TXV 24,000 16.00 13.00 C33-36C SLP98UH090XV36C 7174594 14ACX-024-230A TXV 24,000 16.00 13.00 C33-38A EL180UH045E36A 7174598 14ACX-024-230A TXV 24,000 16.00 13.00 C33-38A EL180UH045XE36A 7174599 14ACX-024-230A TXV 24,000 16.00 13.50 C33-38A SL280UH070V36A 7174596 14ACX-024-230A TXV 24,000 16.00 13.50 C33-38A SL280UH070XV36A 7174597 14ACX-024-230A TXV 24,000 14.50 12.50 C33-38A 7174595 14ACX-024-230A TXV 24,000 16.00 13.50 C33-38B EL180UH070E36B 7174604 14ACX-024-230A TXV 24,000 16.00 13.50 C33-38B EL180UH070XE36B 7174605 14ACX-024-230A TXV 24,000 16.00 13.00 C33-38B EL195UH030XE24B 8608850 14ACX-024-230A TXV 24,000 16.00 13.00 C33-38B EL195UH045XE24B 8608851 14ACX-024-230A TXV 24,000 16.00 13.00 C33-38B EL195UH045XE36B 7174606 14ACX-024-230A TXV 24,000 16.00 13.00 C33-38B EL195UH070XE36B 7174607 14ACX-024-230A TXV 24,000 16.00 13.00 C33-38B EL296UH045XE36B 7174608 14ACX-024-230A TXV 24,000 16.00 13.00 C33-38B EL296UH045XV36B 7174610 14ACX-024-230A TXV 24,000 16.00 13.00 C33-38B EL296UH070XE36B 7174609 14ACX-024-230A TXV 24,000 16.00 13.00 C33-38B EL296UH070XV36B 7174611 14ACX-024-230A TXV 24,000 16.00 13.50 C33-38B SL280UH090V36B 7174601 14ACX-024-230A TXV 24,000 16.00 13.00 C33-38B SL280UH090V48B 7174602 14ACX-024-230A TXV 24,000 16.00 13.00 C33-38B SL280UH090XV48B 7174603 14ACX-024-230A TXV 24,000 16.00 13.00 C33-38B SLP98UH070XV36B 7174612 14ACX-024-230A TXV 24,000 14.50 12.50 C33-38B 7174600 14ACX-024-230A TXV 23,400 15.10 12.50 C35-18/24B EL195UH030XE24B 8608852 14ACX-024-230A TXV 23,400 15.10 12.50 C35-18/24B EL195UH045XE24B 8608853 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24A EL180UH045E36A 8268497 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24A EL180UH045XE36A 8268498 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24A SL280UH070V36A 8268495 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24A SL280UH070XV36A 8268496 14ACX-024-230A TXV 24,000 14.25 12.20 C35-24A 8268494 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24B EL180UH070E36B 8268508 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24B EL180UH070XE36B 8268509 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24B EL195UH030XE24B 8608854 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24B EL195UH045XE24B 8608855 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24B EL195UH045XE36B 8268500 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24B EL195UH070XE36B 8268501 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24B EL296UH045XE36B 8268502 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24B EL296UH045XV36B 8268505 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24B EL296UH070XE36B 8268503 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24B EL296UH070XV36B 8268506 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24B SL280UH090V36B 8268510 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24B SL280UH090V48B 8268511 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24B SL280UH090XV48B 8268504 14ACX-024-230A TXV 24,000 16.00 13.00 C35-24B SLP98UH070XV36B 8268507 14ACX-024-230A TXV 24,000 14.25 12.20 C35-24B 8268499 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36A EL180UH045E36A 8268532 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 133 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36A EL180UH045XE36A 8268533 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36A SL280UH070V36A 8268530 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36A SL280UH070XV36A 8268531 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B EL180UH070E36B 8268543 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B EL180UH070XE36B 8268544 14ACX-024-230A TXV 24,000 15.50 12.50 C35-30/36B EL195UH030XE24B 8608856 14ACX-024-230A TXV 24,000 15.50 12.50 C35-30/36B EL195UH045XE24B 8608857 14ACX-024-230A TXV 23,400 15.50 12.50 C35-30/36B EL195UH045XE36B 8268545 14ACX-024-230A TXV 23,600 16.00 13.00 C35-30/36B EL195UH070XE36B 8268534 14ACX-024-230A TXV 23,400 15.50 12.50 C35-30/36B EL296UH045XE36B 8268535 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B EL296UH045XV36B 8268537 14ACX-024-230A TXV 23,600 16.00 13.00 C35-30/36B EL296UH070XE36B 8268536 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B EL296UH070XV36B 8268538 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B SL280UH090V36B 8268540 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B SL280UH090V48B 8268541 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B SL280UH090XV48B 8268542 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36B SLP98UH070XV36B 8268539 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36C EL296UH090XV36C 8268546 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30/36C SLP98UH090XV36C 8268547 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30A EL180UH045E36A 8268513 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30A EL180UH045XE36A 8268514 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30A SL280UH070V36A 8268515 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30A SL280UH070XV36A 8268516 14ACX-024-230A TXV 24,000 14.50 12.20 C35-30A 8268512 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL180UH070E36B 8268529 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL180UH070XE36B 8268520 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL195UH030XE24B 8608858 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL195UH045XE24B 8608859 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL195UH045XE36B 8268521 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL195UH070XE36B 8268522 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL296UH045XE36B 8268523 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL296UH045XV36B 8268525 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL296UH070XE36B 8268524 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B EL296UH070XV36B 8268518 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B SL280UH090V36B 8268526 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B SL280UH090V48B 8268527 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B SL280UH090XV48B 8268528 14ACX-024-230A TXV 24,000 16.00 13.00 C35-30B SLP98UH070XV36B 8268519 14ACX-024-230A TXV 24,000 14.50 12.20 C35-30B 8268517 14ACX-024-230A TXV 24,000 16.00 13.00 C35-36A EL180UH045E36A 8268551 14ACX-024-230A TXV 24,000 16.00 13.00 C35-36A EL180UH045XE36A 8268552 14ACX-024-230A TXV 24,000 16.00 13.50 C35-36A SL280UH070V36A 8268549 14ACX-024-230A TXV 24,000 16.00 13.50 C35-36A SL280UH070XV36A 8268550 14ACX-024-230A TXV 24,000 14.50 12.50 C35-36A 8268548 14ACX-024-230A TXV 24,000 16.00 13.50 C35-36B EL180UH070E36B 8268563 14ACX-024-230A TXV 24,000 16.00 13.50 C35-36B EL180UH070XE36B 8268564 14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B EL195UH030XE24B 8608860 14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B EL195UH045XE24B 8608861 14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B EL195UH045XE36B 8268565 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 134 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B EL195UH070XE36B 8268554 14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B EL296UH045XE36B 8268555 14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B EL296UH045XV36B 8268557 14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B EL296UH070XE36B 8268556 14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B EL296UH070XV36B 8268558 14ACX-024-230A TXV 24,000 16.00 13.50 C35-36B SL280UH090V36B 8268560 14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B SL280UH090V48B 8268561 14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B SL280UH090XV48B 8268562 14ACX-024-230A TXV 24,000 16.00 13.00 C35-36B SLP98UH070XV36B 8268559 14ACX-024-230A TXV 24,000 14.50 12.50 C35-36B 8268553 14ACX-024-230A TXV 24,000 16.00 13.00 CBA27UHE-024 10259374 14ACX-024-230A TXV 24,000 16.00 13.00 CBA27UHE-030 10259375 14ACX-024-230A TXV 23,600 14.50 12.20 CBX25UH-024 7174613 14ACX-024-230A TXV 23,800 14.50 12.20 CBX25UH-030 7174614 14ACX-024-230A TXV 24,000 14.50 12.20 CBX25UH-036 7174615 14ACX-024-230A TXV 24,000 16.00 13.00 CBX25UHV-024 7174616 14ACX-024-230A TXV 24,000 16.00 13.00 CBX25UHV-030 7174617 14ACX-024-230A TXV 24,000 16.00 13.00 CBX25UHV-036 7174618 14ACX-024-230A TXV 24,000 16.00 13.00 CBX27UH-024 7174619 14ACX-024-230A TXV 24,000 16.00 13.00 CBX27UH-030 7174620 14ACX-024-230A TXV 23,800 14.50 12.20 CBX32M-018/024 7174621 14ACX-024-230A TXV 24,000 15.10 12.50 CBX32M-030 7174622 14ACX-024-230A TXV 24,000 15.50 12.50 CBX32MV-018/024 7174623 14ACX-024-230A TXV 24,000 16.00 13.00 CBX32MV-024/030 7174624 14ACX-024-230A TXV 24,000 16.00 13.00 CBX40UHV-024 8560058 14ACX-024-230A TXV 22,800 15.10 12.50 CH23-31 EL180UH045E36A 7174626 14ACX-024-230A TXV 22,800 15.10 12.50 CH23-31 EL180UH045XE36A 7174627 14ACX-024-230A TXV 23,200 15.50 12.50 CH23-31 EL180UH070E36B 7174628 14ACX-024-230A TXV 23,200 15.50 12.50 CH23-31 EL180UH070XE36B 7174629 14ACX-024-230A TXV 22,800 14.50 12.50 CH23-31 EL195UH030XE24B 8608862 14ACX-024-230A TXV 22,800 14.50 12.50 CH23-31 EL195UH045XE24B 8608863 14ACX-024-230A TXV 23,000 15.10 12.50 CH23-31 EL195UH045XE36B 7174630 14ACX-024-230A TXV 23,000 15.10 12.50 CH23-31 EL195UH070XE36B 7174631 14ACX-024-230A TXV 23,000 15.10 12.50 CH23-31 EL296UH045XE36B 7174632 14ACX-024-230A TXV 23,200 15.50 12.50 CH23-31 EL296UH045XV36B 7174634 14ACX-024-230A TXV 23,000 15.10 12.50 CH23-31 EL296UH070XE36B 7174633 14ACX-024-230A TXV 23,200 15.50 13.00 CH23-31 EL296UH070XV36B 7174635 14ACX-024-230A TXV 23,400 15.10 13.00 CH23-31 SL280UH070V36A 7175365 14ACX-024-230A TXV 23,400 16.00 13.00 CH23-31 SL280UH070XV36A 7175366 14ACX-024-230A TXV 23,200 16.00 13.00 CH23-31 SL280UH090V36B 7174625 14ACX-024-230A TXV 23,200 15.50 13.00 CH23-31 SLP98UH070XV36B 7174636 14ACX-024-230A TXV 24,000 16.00 13.00 CH23-41 EL180UH045E36A 7174641 14ACX-024-230A TXV 24,000 16.00 13.00 CH23-41 EL180UH045XE36A 7174642 14ACX-024-230A TXV 24,000 16.00 13.00 CH23-41 EL180UH070E36B 7174643 14ACX-024-230A TXV 24,000 16.00 13.00 CH23-41 EL180UH070XE36B 7174644 14ACX-024-230A TXV 24,000 15.50 12.50 CH23-41 EL195UH030XE24B 8608864 14ACX-024-230A TXV 24,000 15.50 12.50 CH23-41 EL195UH045XE24B 8608865 14ACX-024-230A TXV 24,000 16.00 13.00 CH23-41 EL195UH045XE36B 7174645 14ACX-024-230A TXV 24,000 16.00 13.00 CH23-41 EL195UH070XE36B 7174646 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 135 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-024-230A TXV 24,000 16.00 13.00 CH23-41 EL296UH045XE36B 7174647 14ACX-024-230A TXV 24,000 16.00 13.00 CH23-41 EL296UH045XV36B 7174649 14ACX-024-230A TXV 24,000 16.00 13.00 CH23-41 EL296UH070XE36B 7174648 14ACX-024-230A TXV 24,000 16.00 13.00 CH23-41 EL296UH070XV36B 7174650 14ACX-024-230A TXV 24,000 16.00 13.00 CH23-41 SL280UH070V36A 7174639 14ACX-024-230A TXV 24,000 16.00 13.00 CH23-41 SL280UH070XV36A 7175367 14ACX-024-230A TXV 24,000 16.00 13.00 CH23-41 SL280UH090V36B 7174640 14ACX-024-230A TXV 24,000 16.00 13.00 CH23-41 SLP98UH070XV36B 7174651 14ACX-024-230A TXV 23,800 15.50 12.50 CH33-19 EL180UH045E36A 7174655 14ACX-024-230A TXV 23,800 15.50 12.50 CH33-19 EL180UH045XE36A 7174656 14ACX-024-230A TXV 24,000 15.10 13.00 CH33-19 SL280UH070V36A 7174653 14ACX-024-230A TXV 24,000 15.10 13.00 CH33-19 SL280UH070XV36A 7174654 14ACX-024-230A TXV 23,800 15.50 12.50 CH33-24/30 EL180UH045E36A 7174660 14ACX-024-230A TXV 23,800 15.50 12.50 CH33-24/30 EL180UH045XE36A 7174661 14ACX-024-230A TXV 23,800 15.10 13.00 CH33-24/30 SL280UH070V36A 7174658 14ACX-024-230A TXV 23,800 15.10 13.00 CH33-24/30 SL280UH070XV36A 7174659 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-25A EL180UH045E36A 7174665 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-25A EL180UH045XE36A 7174666 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-25A SL280UH070V36A 7174663 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-25A SL280UH070XV36A 7174664 14ACX-024-230A TXV 24,000 14.50 12.20 CH33-25A 7174662 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-25B EL180UH070E36B 7174669 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-25B EL180UH070XE36B 7174670 14ACX-024-230A TXV 24,000 15.50 12.50 CH33-25B EL195UH030XE24B 8608866 14ACX-024-230A TXV 24,000 15.50 12.50 CH33-25B EL195UH045XE24B 8608867 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-25B EL195UH045XE36B 7174671 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-25B EL195UH070XE36B 7174672 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-25B EL296UH045XE36B 7174673 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-25B EL296UH045XV36B 7174675 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-25B EL296UH070XE36B 7174674 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-25B EL296UH070XV36B 7174676 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-25B SL280UH090V36B 7174668 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-25B SLP98UH070XV36B 7174677 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-31A EL180UH045E36A 7174681 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-31A EL180UH045XE36A 7174682 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-31A SL280UH070V36A 7174679 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-31A SL280UH070XV36A 7174680 14ACX-024-230A TXV 24,000 14.50 12.50 CH33-31A 7174678 14ACX-024-230A TXV 24,000 16.00 13.50 CH33-31B EL180UH070E36B 7174685 14ACX-024-230A TXV 24,000 16.00 13.50 CH33-31B EL180UH070XE36B 7174686 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-31B EL195UH030XE24B 8608868 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-31B EL195UH045XE24B 8608869 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-31B EL195UH045XE36B 7174687 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-31B EL195UH070XE36B 7174688 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-31B EL296UH045XE36B 7174689 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-31B EL296UH045XV36B 7174691 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-31B EL296UH070XE36B 7174690 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-31B EL296UH070XV36B 7174692 14ACX-024-230A TXV 24,000 16.00 13.50 CH33-31B SL280UH090V36B 7174684 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 136 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-31B SLP98UH070XV36B 7174693 14ACX-024-230A TXV 24,000 14.50 12.50 CH33-31B 7174683 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36A EL180UH045E36A 7174698 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36A EL180UH045XE36A 7174699 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36A SL280UH070V36A 7174696 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36A SL280UH070XV36A 7174697 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36B EL180UH070E36B 7174703 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36B EL180UH070XE36B 7174704 14ACX-024-230A TXV 24,000 15.50 12.50 CH33-36B EL195UH030XE24B 8608870 14ACX-024-230A TXV 24,000 15.50 12.50 CH33-36B EL195UH045XE24B 8608871 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36B EL195UH045XE36B 7174705 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36B EL195UH070XE36B 7174706 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36B EL296UH045XE36B 7174707 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36B EL296UH045XV36B 7174709 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36B EL296UH070XE36B 7174708 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36B EL296UH070XV36B 7174710 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36B SL280UH090V36B 7174702 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36B SLP98UH070XV36B 7174711 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36C EL296UH090XV36C 7174714 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-36C SLP98UH090XV36C 7174715 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-42 EL195UH030XE24B 8608872 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-42 EL195UH045XE24B 8608873 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-43B EL195UH030XE24B 8608874 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-43B EL195UH045XE24B 8608875 14ACX-024-230A TXV 24,000 16.00 13.00 CH33-43B EL195UH045XE36B 8237805 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-18A EL180UH045E36A 7174719 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-18A EL180UH045XE36A 7174720 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-18A SL280UH070V36A 7174717 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-18A SL280UH070XV36A 7174718 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-24A EL180UH045E36A 7174725 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-24A EL180UH045XE36A 7174726 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-24A SL280UH070V36A 7174723 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-24A SL280UH070XV36A 7174724 14ACX-024-230A TXV 23,800 14.50 12.20 CH35-24A 7174722 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-24B EL180UH070E36B 7174730 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-24B EL180UH070XE36B 7174731 14ACX-024-230A TXV 24,000 15.50 12.50 CH35-24B EL195UH030XE24B 8608876 14ACX-024-230A TXV 24,000 15.50 12.50 CH35-24B EL195UH045XE24B 8608877 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-24B EL195UH045XE36B 7174732 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-24B EL195UH070XE36B 7174733 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-24B EL296UH045XV36B 7174734 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-24B EL296UH070XV36B 7174735 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-24B SL280UH090V36B 7174729 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-24B SLP98UH070XV36B 7174736 14ACX-024-230A TXV 24,000 14.50 12.20 CH35-24B 7174728 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-30A EL180UH045E36A 7174741 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-30A EL180UH045XE36A 7174742 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-30A SL280UH070V36A 7174739 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-30A SL280UH070XV36A 7174740 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 137 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-024-230A TXV 24,000 15.00 12.50 CH35-30A 7174738 14ACX-024-230A TXV 24,000 16.00 13.50 CH35-30B EL180UH070E36B 7174746 14ACX-024-230A TXV 24,000 16.00 13.50 CH35-30B EL180UH070XE36B 7174747 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-30B EL195UH030XE24B 8608878 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-30B EL195UH045XE24B 8608879 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-30B EL195UH045XE36B 7174748 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-30B EL195UH070XE36B 7174749 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-30B EL296UH045XV36B 7174750 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-30B EL296UH070XV36B 7174751 14ACX-024-230A TXV 24,000 16.00 13.50 CH35-30B SL280UH090V36B 7174745 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-30B SLP98UH070XV36B 7174752 14ACX-024-230A TXV 24,000 14.50 12.50 CH35-30B 7174744 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-36A EL180UH045E36A 7174756 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-36A EL180UH045XE36A 7174757 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-36A SL280UH070V36A 7174754 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-36A SL280UH070XV36A 7174755 14ACX-024-230A TXV 23,800 14.25 12.20 CH35-36A 7174753 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-36B EL180UH070E36B 7174760 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-36B EL180UH070XE36B 7174761 14ACX-024-230A TXV 24,000 15.50 12.50 CH35-36B EL195UH030XE24B 8608880 14ACX-024-230A TXV 24,000 15.50 12.50 CH35-36B EL195UH045XE24B 8608881 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-36B EL195UH045XE36B 7174762 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-36B EL195UH070XE36B 7174763 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-36B EL296UH045XV36B 7174764 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-36B EL296UH070XV36B 7174765 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-36B SL280UH090V36B 7174759 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-36B SLP98UH070XV36B 7174766 14ACX-024-230A TXV 23,800 14.00 12.20 CH35-36B 7174758 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-36C EL296UH090XV36C 7174768 14ACX-024-230A TXV 24,000 16.00 13.00 CH35-36C SLP98UH090XV36C 7174769 14ACX-024-230A TXV 24,000 14.25 12.20 CH35-36C 7174767 14ACX-024-230A TXV 23,400 15.10 12.50 CR33-24A EL180DF045E36A 7174771 14ACX-024-230A TXV 23,000 15.10 12.50 CR33-24A SL280DF070V36A 7174770 14ACX-024-230A TXV 23,000 15.10 12.50 CR33-24B EL180DF070E36B 7174772 14ACX-024-230A TXV 22,600 15.00 12.50 CR33-24B EL195DF045XE36B 7174773 14ACX-024-230A TXV 22,800 15.00 12.50 CR33-24B EL195DF070XE48B 7174774 14ACX-024-230A TXV 22,600 15.00 12.50 CR33-24B EL296DF045XE36B 7174775 14ACX-024-230A TXV 23,000 15.10 12.50 CR33-24B EL296DF045XV36B 7174777 14ACX-024-230A TXV 22,800 15.00 12.50 CR33-24B EL296DF070XE48B 7174776 14ACX-024-230A TXV 23,400 15.00 12.50 CR33-24B EL296DF070XV48B 8247147 14ACX-024-230A TXV 23,200 15.10 12.50 CR33-24B SLP98DF070XV36B 7174778 14ACX-024-230A TXV 24,000 16.00 13.00 CR33-30/36A EL180DF045E36A 7174781 14ACX-024-230A TXV 24,000 16.00 13.00 CR33-30/36A SL280DF070V36A 7174780 14ACX-024-230A TXV 24,000 14.50 12.20 CR33-30/36A 7174779 14ACX-024-230A TXV 24,000 16.00 13.00 CR33-30/36B EL180DF070E36B 7174783 14ACX-024-230A TXV 24,000 16.00 13.00 CR33-30/36B EL195DF045XE36B 7174784 14ACX-024-230A TXV 24,000 16.00 13.00 CR33-30/36B EL195DF070XE48B 7174785 14ACX-024-230A TXV 24,000 16.00 13.00 CR33-30/36B EL296DF045XE36B 7174786 14ACX-024-230A TXV 24,000 16.00 13.00 CR33-30/36B EL296DF045XV36B 7174789 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 138 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-024-230A TXV 24,000 16.00 13.00 CR33-30/36B EL296DF070XE48B 7174787 14ACX-024-230A TXV 24,000 16.00 13.00 CR33-30/36B EL296DF070XV48B 7174790 14ACX-024-230A TXV 24,000 16.00 13.00 CR33-30/36B SL280DF090V48B 7174788 14ACX-024-230A TXV 24,000 16.00 13.00 CR33-30/36B SLP98DF070XV36B 7174791 14ACX-024-230A TXV 24,000 14.50 12.20 CR33-30/36B 7174782 14ACX-024-230A TXV 24,000 16.00 13.00 CR33-30/36C SLP98DF090XV36C 7174793 14ACX-024-230A TXV 24,000 14.50 12.20 CR33-30/36C 7174792 14ACX-024-230A TXV 22,800 15.00 12.50 CX34-18/24A EL180UH045E36A 7174794 14ACX-024-230A TXV 22,800 15.00 12.50 CX34-18/24A EL180UH045XE36A 7174795 14ACX-024-230A TXV 22,800 14.50 12.20 CX34-18/24B EL195UH030XE24B 8608882 14ACX-024-230A TXV 22,800 14.50 12.20 CX34-18/24B EL195UH045XE24B 8608883 14ACX-024-230A TXV 23,800 16.00 13.00 CX34-19 EL180UH045E36A 7174799 14ACX-024-230A TXV 23,800 16.00 13.00 CX34-19 EL180UH045XE36A 7174800 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-19 SL280UH070V36A 7174797 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-19 SL280UH070XV36A 7174798 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25A EL180UH045E36A 7174804 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25A EL180UH045XE36A 7174805 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25A SL280UH070V36A 7174802 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25A SL280UH070XV36A 7174803 14ACX-024-230A TXV 23,800 14.25 12.20 CX34-25A 7174801 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL180UH070E36B 7174813 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL180UH070XE36B 7174814 14ACX-024-230A TXV 24,000 15.50 12.50 CX34-25B EL195UH030XE24B 8608884 14ACX-024-230A TXV 24,000 15.50 12.50 CX34-25B EL195UH045XE24B 8608885 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL195UH045XE36B 7174815 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL195UH070XE36B 7174816 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL296UH045XE36B 7174817 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL296UH045XV36B 7174810 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL296UH070XE36B 7174818 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B EL296UH070XV36B 7174811 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B SL280UH090V36B 7174807 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B SL280UH090V48B 7174808 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B SL280UH090XV48B 7174809 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-25B SLP98UH070XV36B 7174812 14ACX-024-230A TXV 23,800 14.25 12.20 CX34-25B 7174806 14ACX-024-230A TXV 23,600 15.50 12.50 CX34-30A EL180UH045E36A 7174823 14ACX-024-230A TXV 23,600 15.50 12.50 CX34-30A EL180UH045XE36A 7174824 14ACX-024-230A TXV 23,600 15.10 12.50 CX34-30A SL280UH070V36A 7174821 14ACX-024-230A TXV 23,600 15.10 12.50 CX34-30A SL280UH070XV36A 7174822 14ACX-024-230A TXV 23,400 15.50 12.50 CX34-30B EL180UH070E36B 7174828 14ACX-024-230A TXV 23,400 15.50 12.50 CX34-30B EL180UH070XE36B 7174829 14ACX-024-230A TXV 23,400 15.10 12.50 CX34-30B EL195UH030XE24B 8608886 14ACX-024-230A TXV 23,400 15.10 12.50 CX34-30B EL195UH045XE24B 8608887 14ACX-024-230A TXV 23,000 15.10 12.50 CX34-30B EL195UH045XE36B 7174830 14ACX-024-230A TXV 23,400 15.50 12.50 CX34-30B EL195UH070XE36B 7174831 14ACX-024-230A TXV 23,000 15.10 12.50 CX34-30B EL296UH045XE36B 7174832 14ACX-024-230A TXV 23,600 15.50 12.50 CX34-30B EL296UH045XV36B 7174834 14ACX-024-230A TXV 23,400 15.50 12.50 CX34-30B EL296UH070XE36B 7174833 14ACX-024-230A TXV 23,600 15.50 12.50 CX34-30B EL296UH070XV36B 7174835 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 139 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-024-230A TXV 23,600 15.10 13.00 CX34-30B SL280UH090V36B 7174825 14ACX-024-230A TXV 23,600 15.10 12.50 CX34-30B SL280UH090V48B 7174826 14ACX-024-230A TXV 23,600 15.10 12.50 CX34-30B SL280UH090XV48B 7174827 14ACX-024-230A TXV 23,600 15.50 12.50 CX34-30B SLP98UH070XV36B 7174836 14ACX-024-230A TXV 23,600 16.00 13.00 CX34-30C EL296UH090XV36C 7174837 14ACX-024-230A TXV 23,600 16.00 13.00 CX34-30C SLP98UH090XV36C 7174838 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31A EL180UH045E36A 7174842 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31A EL180UH045XE36A 7174843 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31A SL280UH070V36A 7174840 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31A SL280UH070XV36A 7174841 14ACX-024-230A TXV 24,000 14.50 12.20 CX34-31A 7174839 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31B EL180UH070E36B 7174848 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31B EL180UH070XE36B 7174849 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31B EL195UH030XE24B 8608888 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31B EL195UH045XE24B 8608889 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31B EL195UH045XE36B 7174850 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31B EL195UH070XE36B 7174851 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31B EL296UH045XE36B 7174852 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31B EL296UH045XV36B 7174854 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31B EL296UH070XE36B 7174853 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31B EL296UH070XV36B 7174855 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31B SL280UH090V36B 7174845 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31B SL280UH090V48B 7174846 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31B SL280UH090XV48B 7174847 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-31B SLP98UH070XV36B 7174856 14ACX-024-230A TXV 24,000 14.50 12.20 CX34-31B 7174844 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-36A EL180UH045E36A 7174863 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-36A EL180UH045XE36A 7174862 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-36A SL280UH070V36A 7174860 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-36A SL280UH070XV36A 7174861 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-36B EL180UH070E36B 7174867 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-36B EL180UH070XE36B 7174868 14ACX-024-230A TXV 24,000 15.50 12.50 CX34-36B EL195UH030XE24B 8608890 14ACX-024-230A TXV 24,000 15.50 12.50 CX34-36B EL195UH045XE24B 8608891 14ACX-024-230A TXV 23,400 15.50 12.50 CX34-36B EL195UH045XE36B 7174869 14ACX-024-230A TXV 23,600 15.50 13.00 CX34-36B EL195UH070XE36B 7174870 14ACX-024-230A TXV 23,400 15.50 12.50 CX34-36B EL296UH045XE36B 7174871 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-36B EL296UH045XV36B 7174873 14ACX-024-230A TXV 23,600 15.50 13.00 CX34-36B EL296UH070XE36B 7174872 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-36B EL296UH070XV36B 7174874 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-36B SL280UH090V36B 7174864 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-36B SL280UH090V48B 7174865 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-36B SL280UH090XV48B 7174866 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-36B SLP98UH070XV36B 7174875 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-36C EL296UH090XV36C 7174876 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-36C SLP98UH090XV36C 7174877 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-38A EL180UH045E36A 7174881 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-38A EL180UH045XE36A 7174882 14ACX-024-230A TXV 24,000 16.00 13.50 CX34-38A SL280UH070V36A 7174879 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 140 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-024-230A TXV 24,000 16.00 13.50 CX34-38A SL280UH070XV36A 7174880 14ACX-024-230A TXV 24,000 14.50 12.50 CX34-38A 7174878 14ACX-024-230A TXV 24,000 16.00 13.50 CX34-38B EL180UH070E36B 7174887 14ACX-024-230A TXV 24,000 16.00 13.50 CX34-38B EL180UH070XE36B 7174888 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-38B EL195UH030XE24B 8608892 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-38B EL195UH045XE24B 8608893 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-38B EL195UH045XE36B 7174889 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-38B EL195UH070XE36B 7174890 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-38B EL296UH045XE36B 7174891 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-38B EL296UH045XV36B 7174893 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-38B EL296UH070XE36B 7174892 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-38B EL296UH070XV36B 7174894 14ACX-024-230A TXV 24,000 16.00 13.50 CX34-38B SL280UH090V36B 7174884 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-38B SL280UH090V48B 7174885 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-38B SL280UH090XV48B 7174886 14ACX-024-230A TXV 24,000 16.00 13.00 CX34-38B SLP98UH070XV36B 7174895 14ACX-024-230A TXV 24,000 14.50 12.50 CX34-38B 7174883 14ACX-024-230A TXV 22,800 15.00 12.50 CX35-18/24A EL180UH045E36A 8268566 14ACX-024-230A TXV 22,800 15.00 12.50 CX35-18/24A EL180UH045XE36A 8268567 14ACX-024-230A TXV 23,400 15.10 12.50 CX35-18/24B EL195UH030XE24B 8608894 14ACX-024-230A TXV 23,400 15.00 12.50 CX35-18/24B EL195UH045XE24B 8608895 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24A EL180UH045E36A 8268569 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24A EL180UH045XE36A 8268570 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24A SL280UH070V36A 8268571 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24A SL280UH070XV36A 8268572 14ACX-024-230A TXV 24,000 14.25 12.20 CX35-24A 8268568 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24B EL180UH070E36B 8268578 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24B EL180UH070XE36B 8268579 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24B EL195UH030XE24B 8608896 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24B EL195UH045XE24B 8608897 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24B EL195UH045XE36B 8268580 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24B EL195UH070XE36B 8268581 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24B EL296UH045XE36B 8268574 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24B EL296UH045XV36B 8268585 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24B EL296UH070XE36B 8268575 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24B EL296UH070XV36B 8268576 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24B SL280UH090V36B 8268582 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24B SL280UH090V48B 8268583 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24B SL280UH090XV48B 8268584 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-24B SLP98UH070XV36B 8268577 14ACX-024-230A TXV 24,000 14.25 12.20 CX35-24B 8268573 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30/36A EL180UH045E36A 8268607 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30/36A EL180UH045XE36A 8268606 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30/36A SL280UH070V36A 8268604 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30/36A SL280UH070XV36A 8268605 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30/36B EL180UH070E36B 8268613 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30/36B EL180UH070XE36B 8268614 14ACX-024-230A TXV 24,000 15.50 12.50 CX35-30/36B EL195UH030XE24B 8608898 14ACX-024-230A TXV 24,000 15.50 12.50 CX35-30/36B EL195UH045XE24B 8608899 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 141 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-024-230A TXV 23,400 15.50 12.50 CX35-30/36B EL195UH045XE36B 8268615 14ACX-024-230A TXV 23,600 16.00 13.00 CX35-30/36B EL195UH070XE36B 8268616 14ACX-024-230A TXV 23,400 15.50 12.50 CX35-30/36B EL296UH045XE36B 8268617 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30/36B EL296UH045XV36B 8268609 14ACX-024-230A TXV 23,600 16.00 13.00 CX35-30/36B EL296UH070XE36B 8268608 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30/36B EL296UH070XV36B 8268610 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30/36B SL280UH090V36B 8268618 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30/36B SL280UH090V48B 8268619 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30/36B SL280UH090XV48B 8268612 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30/36B SLP98UH070XV36B 8268611 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30/36C EL296UH090XV36C 8268620 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30/36C SLP98UH090XV36C 8268621 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30A EL180UH045E36A 8268589 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30A EL180UH045XE36A 8268590 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30A SL280UH070V36A 8268587 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30A SL280UH070XV36A 8268588 14ACX-024-230A TXV 24,000 14.50 12.20 CX35-30A 8268586 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30B EL180UH070E36B 8268601 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30B EL180UH070XE36B 8268602 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30B EL195UH030XE24B 8608900 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30B EL195UH045XE24B 8608901 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30B EL195UH045XE36B 8268603 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30B EL195UH070XE36B 8268592 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30B EL296UH045XE36B 8268593 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30B EL296UH045XV36B 8268595 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30B EL296UH070XE36B 8268594 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30B EL296UH070XV36B 8268596 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30B SL280UH090V36B 8268598 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30B SL280UH090V48B 8268599 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30B SL280UH090XV48B 8268600 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-30B SLP98UH070XV36B 8268597 14ACX-024-230A TXV 24,000 14.50 12.20 CX35-30B 8268591 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-36A EL180UH045E36A 8268625 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-36A EL180UH045XE36A 8268626 14ACX-024-230A TXV 24,000 16.00 13.50 CX35-36A SL280UH070V36A 8268623 14ACX-024-230A TXV 24,000 16.00 13.50 CX35-36A SL280UH070XV36A 8268624 14ACX-024-230A TXV 24,000 14.50 12.50 CX35-36A 8268622 14ACX-024-230A TXV 24,000 16.00 13.50 CX35-36B EL180UH070E36B 8268633 14ACX-024-230A TXV 24,000 16.00 13.50 CX35-36B EL180UH070XE36B 8268634 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-36B EL195UH030XE24B 8608902 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-36B EL195UH045XE24B 8608903 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-36B EL195UH045XE36B 8268635 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-36B EL195UH070XE36B 8268636 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-36B EL296UH045XE36B 8268637 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-36B EL296UH045XV36B 8268629 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-36B EL296UH070XE36B 8268628 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-36B EL296UH070XV36B 8268630 14ACX-024-230A TXV 24,000 16.00 13.50 CX35-36B SL280UH090V36B 8268638 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-36B SL280UH090V48B 8268639 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 142 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-36B SL280UH090XV48B 8268632 14ACX-024-230A TXV 24,000 16.00 13.00 CX35-36B SLP98UH070XV36B 8268631 14ACX-024-230A TXV 24,000 14.50 12.50 CX35-36B 8268627 14ACX-030-230A RFC 28,000 14.25 12.20 C33-31A 7509839 14ACX-030-230A RFC 28,000 14.25 12.20 C33-31B 7509845 14ACX-030-230A RFC 28,000 14.25 12.20 C33-38A 7509879 14ACX-030-230A RFC 28,000 14.25 12.20 C33-38B 7509885 14ACX-030-230A RFC 28,000 14.50 12.20 C33-43 7513088 14ACX-030-230A RFC 28,000 14.00 12.20 C35-30A 8471009 14ACX-030-230A RFC 28,000 14.00 12.20 C35-30B 8471011 14ACX-030-230A RFC 28,000 14.00 12.20 C35-36A 8471013 14ACX-030-230A RFC 28,000 14.00 12.20 C35-36B 8471015 14ACX-030-230A RFC 27,400 14.00 12.20 C35-48B 8471016 14ACX-030-230A RFC 27,400 14.00 12.20 C35-48C 8471017 14ACX-030-230A RFC 28,000 14.25 12.20 CH33-31A 7509971 14ACX-030-230A RFC 28,000 14.25 12.20 CH33-31B 7509977 14ACX-030-230A RFC 28,000 14.00 12.20 CH33-42B 7510015 14ACX-030-230A RFC 28,000 14.50 12.50 CH33-43B 7510016 14ACX-030-230A TXV 28,000 15.10 12.50 C33-25A EL180UH045E36A 7509809 14ACX-030-230A TXV 28,000 15.10 12.50 C33-25A EL180UH045XE36A 7509810 14ACX-030-230A TXV 28,000 15.50 12.50 C33-25A SL280UH070V36A 7509807 14ACX-030-230A TXV 28,000 15.50 12.50 C33-25A SL280UH070XV36A 7509808 14ACX-030-230A TXV 28,000 15.50 12.50 C33-25B EL180UH070E36B 7509816 14ACX-030-230A TXV 28,000 15.50 12.50 C33-25B EL180UH070XE36B 7509817 14ACX-030-230A TXV 27,800 15.50 12.50 C33-25B EL180UH090E48B 7509813 14ACX-030-230A TXV 27,800 15.50 12.50 C33-25B EL180UH090XE48B 7509814 14ACX-030-230A TXV 28,000 15.10 12.50 C33-25B EL195UH045XE36B 7509818 14ACX-030-230A TXV 28,000 15.00 12.50 C33-25B EL195UH070XE36B 7509820 14ACX-030-230A TXV 28,000 15.10 12.50 C33-25B EL296UH045XE36B 7509819 14ACX-030-230A TXV 28,000 15.00 12.50 C33-25B EL296UH070XE36B 7509821 14ACX-030-230A TXV 28,000 15.10 12.50 C33-25B EL296UH070XV36B 7509822 14ACX-030-230A TXV 28,000 15.50 12.50 C33-25B SL280UH090V36B 7509815 14ACX-030-230A TXV 28,000 15.10 12.50 C33-25B SLP98UH070XV36B 7509823 14ACX-030-230A TXV 27,400 15.00 12.50 C33-30A EL180UH045E36A 7509830 14ACX-030-230A TXV 27,400 15.00 12.50 C33-30A EL180UH045XE36A 7509831 14ACX-030-230A TXV 27,400 15.00 12.50 C33-30A SL280UH070V36A 7509828 14ACX-030-230A TXV 27,400 15.00 12.50 C33-30A SL280UH070XV36A 7509829 14ACX-030-230A TXV 27,400 15.10 12.50 C33-30B EL180UH070E36B 7509832 14ACX-030-230A TXV 27,400 15.10 12.50 C33-30B EL180UH070XE36B 7509833 14ACX-030-230A TXV 27,200 15.10 12.50 C33-30B EL180UH090E48B 7509824 14ACX-030-230A TXV 27,200 15.10 12.50 C33-30B EL180UH090XE48B 7509825 14ACX-030-230A TXV 27,200 14.50 12.50 C33-30B EL195UH045XE36B 7509826 14ACX-030-230A TXV 27,400 14.50 12.50 C33-30B EL195UH070XE36B 7509834 14ACX-030-230A TXV 27,200 14.50 12.50 C33-30B EL296UH045XE36B 7509827 14ACX-030-230A TXV 27,400 14.50 12.50 C33-30B EL296UH070XE36B 7509835 14ACX-030-230A TXV 27,400 15.00 12.50 C33-30B EL296UH070XV36B 7509836 14ACX-030-230A TXV 27,600 15.10 12.50 C33-30B SL280UH090V36B 7509838 14ACX-030-230A TXV 27,400 15.00 12.50 C33-30B SLP98UH070XV36B 7509837 14ACX-030-230A TXV 27,400 15.10 12.50 C33-30C SLP98UH090XV36C 7513073 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 143 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-030-230A TXV 28,000 15.50 12.50 C33-31A EL180UH045E36A 7509843 14ACX-030-230A TXV 28,000 15.50 12.50 C33-31A EL180UH045XE36A 7509844 14ACX-030-230A TXV 28,000 16.00 13.00 C33-31A SL280UH070V36A 7509841 14ACX-030-230A TXV 28,000 16.00 13.00 C33-31A SL280UH070XV36A 7509842 14ACX-030-230A TXV 28,000 14.25 12.20 C33-31A 7509840 14ACX-030-230A TXV 28,000 16.00 13.00 C33-31B EL180UH070E36B 7509848 14ACX-030-230A TXV 28,000 16.00 13.00 C33-31B EL180UH070XE36B 7509849 14ACX-030-230A TXV 28,000 16.00 13.00 C33-31B EL180UH090E48B 7509850 14ACX-030-230A TXV 28,000 16.00 13.00 C33-31B EL180UH090XE48B 7509851 14ACX-030-230A TXV 28,000 15.50 12.50 C33-31B EL195UH045XE36B 7509852 14ACX-030-230A TXV 28,000 15.10 12.50 C33-31B EL195UH070XE36B 7509854 14ACX-030-230A TXV 28,000 15.50 12.50 C33-31B EL296UH045XE36B 7509853 14ACX-030-230A TXV 28,000 15.10 12.50 C33-31B EL296UH070XE36B 7509855 14ACX-030-230A TXV 28,000 16.00 13.00 C33-31B EL296UH070XV36B 7509856 14ACX-030-230A TXV 28,000 16.00 13.00 C33-31B SL280UH090V36B 7509847 14ACX-030-230A TXV 28,000 16.00 13.00 C33-31B SLP98UH070XV36B 7509857 14ACX-030-230A TXV 28,000 14.25 12.20 C33-31B 7509846 14ACX-030-230A TXV 28,000 15.10 12.50 C33-36A EL180UH045E36A 7509861 14ACX-030-230A TXV 28,000 15.10 12.50 C33-36A EL180UH045XE36A 7509862 14ACX-030-230A TXV 28,000 15.50 12.50 C33-36A SL280UH070V36A 7509859 14ACX-030-230A TXV 28,000 15.50 12.50 C33-36A SL280UH070XV36A 7509860 14ACX-030-230A TXV 28,000 15.50 12.50 C33-36B EL180UH070E36B 7509866 14ACX-030-230A TXV 28,000 15.50 12.50 C33-36B EL180UH070XE36B 7509867 14ACX-030-230A TXV 28,000 15.50 12.50 C33-36B EL180UH090E48B 7509868 14ACX-030-230A TXV 28,000 15.50 12.50 C33-36B EL180UH090XE48B 7509869 14ACX-030-230A TXV 28,000 15.10 12.50 C33-36B EL195UH045XE36B 7509870 14ACX-030-230A TXV 28,000 15.10 12.50 C33-36B EL195UH070XE36B 7509872 14ACX-030-230A TXV 28,000 15.10 12.50 C33-36B EL296UH045XE36B 7509871 14ACX-030-230A TXV 27,800 15.10 12.50 C33-36B EL296UH045XV36B 7513074 14ACX-030-230A TXV 28,000 15.10 12.50 C33-36B EL296UH070XE36B 7509873 14ACX-030-230A TXV 28,000 15.50 12.50 C33-36B EL296UH070XV36B 7509864 14ACX-030-230A TXV 28,000 15.50 12.50 C33-36B SL280UH090V36B 7509865 14ACX-030-230A TXV 28,000 15.50 12.50 C33-36B SLP98UH070XV36B 7509874 14ACX-030-230A TXV 28,000 15.10 12.50 C33-36C EL195UH090XE48C 7509875 14ACX-030-230A TXV 28,000 15.10 12.50 C33-36C EL296UH090XE48C 7509876 14ACX-030-230A TXV 28,000 15.50 12.50 C33-36C EL296UH090XV36C 7509877 14ACX-030-230A TXV 28,000 15.50 12.50 C33-36C SLP98UH090XV36C 7509878 14ACX-030-230A TXV 28,000 16.00 13.00 C33-38A EL180UH045E36A 7509883 14ACX-030-230A TXV 28,000 16.00 13.00 C33-38A EL180UH045XE36A 7509884 14ACX-030-230A TXV 28,000 16.00 13.00 C33-38A SL280UH070V36A 7509881 14ACX-030-230A TXV 28,000 16.00 13.00 C33-38A SL280UH070XV36A 7509882 14ACX-030-230A TXV 28,000 14.50 12.20 C33-38A 7509880 14ACX-030-230A TXV 28,000 16.00 13.00 C33-38B EL180UH070E36B 7509888 14ACX-030-230A TXV 28,000 16.00 13.00 C33-38B EL180UH070XE36B 7509889 14ACX-030-230A TXV 28,000 16.00 13.00 C33-38B EL180UH090E48B 7509890 14ACX-030-230A TXV 28,000 16.00 13.00 C33-38B EL180UH090XE48B 7509891 14ACX-030-230A TXV 28,000 15.50 12.50 C33-38B EL195UH045XE36B 7509892 14ACX-030-230A TXV 28,000 15.50 12.50 C33-38B EL195UH070XE36B 7509894 14ACX-030-230A TXV 28,000 15.50 12.50 C33-38B EL296UH045XE36B 7509893 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 144 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-030-230A TXV 28,000 15.50 12.50 C33-38B EL296UH045XV36B 7509896 14ACX-030-230A TXV 28,000 15.50 12.50 C33-38B EL296UH070XE36B 7509895 14ACX-030-230A TXV 28,000 16.00 13.00 C33-38B EL296UH070XV36B 7509897 14ACX-030-230A TXV 28,000 16.00 13.00 C33-38B SL280UH090V36B 7509887 14ACX-030-230A TXV 28,000 16.00 13.00 C33-38B SLP98UH070XV36B 7509898 14ACX-030-230A TXV 28,000 14.50 12.20 C33-38B 7509886 14ACX-030-230A TXV 28,000 16.00 13.00 C33-42 EL180UH070E36B 7513077 14ACX-030-230A TXV 28,000 16.00 13.00 C33-42 EL180UH070XE36B 7513078 14ACX-030-230A TXV 28,000 16.00 13.00 C33-42 EL180UH090E48B 7513079 14ACX-030-230A TXV 28,000 16.00 13.00 C33-42 EL180UH090XE48B 7513080 14ACX-030-230A TXV 28,000 15.50 12.50 C33-42 EL195UH045XE36B 7513081 14ACX-030-230A TXV 28,000 15.50 12.50 C33-42 EL195UH070XE36B 7513083 14ACX-030-230A TXV 28,000 15.50 12.50 C33-42 EL296UH045XE36B 7513082 14ACX-030-230A TXV 28,000 15.50 12.50 C33-42 EL296UH045XV36B 7513085 14ACX-030-230A TXV 28,000 15.50 12.50 C33-42 EL296UH070XE36B 7513084 14ACX-030-230A TXV 28,000 16.00 13.00 C33-42 EL296UH070XV36B 7513086 14ACX-030-230A TXV 28,000 15.50 12.50 C33-42 SL280UH090V36B 7513076 14ACX-030-230A TXV 28,000 16.00 13.00 C33-42 SLP98UH070XV36B 7513087 14ACX-030-230A TXV 28,000 16.00 13.00 C33-43B EL180UH070E36B 7509901 14ACX-030-230A TXV 28,000 16.00 13.00 C33-43B EL180UH070XE36B 7509902 14ACX-030-230A TXV 28,000 16.00 13.00 C33-43B EL180UH090E48B 7509903 14ACX-030-230A TXV 28,000 16.00 13.00 C33-43B EL180UH090XE48B 7509904 14ACX-030-230A TXV 28,000 15.50 12.50 C33-43B EL195UH045XE36B 7509905 14ACX-030-230A TXV 28,000 15.50 12.50 C33-43B EL195UH070XE36B 7509907 14ACX-030-230A TXV 28,000 15.50 12.50 C33-43B EL296UH045XE36B 7509906 14ACX-030-230A TXV 28,000 15.50 12.50 C33-43B EL296UH045XV36B 7509909 14ACX-030-230A TXV 28,000 15.50 12.50 C33-43B EL296UH070XE36B 7509908 14ACX-030-230A TXV 28,000 16.00 13.00 C33-43B EL296UH070XV36B 7509910 14ACX-030-230A TXV 28,000 16.00 13.00 C33-43B SL280UH090V36B 7509900 14ACX-030-230A TXV 28,000 16.00 13.00 C33-43B SLP98UH070XV36B 7509911 14ACX-030-230A TXV 28,000 14.50 12.20 C33-43B 7509899 14ACX-030-230A TXV 28,000 16.00 13.00 C33-43C EL195UH090XE48C 7509913 14ACX-030-230A TXV 28,000 16.00 13.00 C33-43C EL296UH090XE48C 7509914 14ACX-030-230A TXV 28,000 16.00 13.00 C33-43C EL296UH090XV36C 7509915 14ACX-030-230A TXV 28,000 16.00 13.00 C33-43C EL296UH090XV48C 7509917 14ACX-030-230A TXV 28,000 16.00 13.00 C33-43C SLP98UH090XV36C 7509916 14ACX-030-230A TXV 28,000 16.00 13.00 C33-43C SLP98UH090XV48C 7509918 14ACX-030-230A TXV 28,000 14.50 12.20 C33-43C 7509912 14ACX-030-230A TXV 28,000 15.10 12.50 C35-24A EL180UH045E36A 8268314 14ACX-030-230A TXV 28,000 15.10 12.50 C35-24A EL180UH045XE36A 8268315 14ACX-030-230A TXV 28,000 15.50 12.50 C35-24A SL280UH070V36A 8268312 14ACX-030-230A TXV 28,000 15.50 12.50 C35-24A SL280UH070XV36A 8268313 14ACX-030-230A TXV 28,000 15.50 12.50 C35-24B EL180UH070E36B 8268318 14ACX-030-230A TXV 28,000 15.50 12.50 C35-24B EL180UH070XE36B 8268319 14ACX-030-230A TXV 27,800 15.50 12.50 C35-24B EL180UH090E48B 8268316 14ACX-030-230A TXV 27,800 15.50 12.50 C35-24B EL180UH090XE48B 8268317 14ACX-030-230A TXV 28,000 15.10 12.50 C35-24B EL195UH045XE36B 8268320 14ACX-030-230A TXV 28,000 15.00 12.50 C35-24B EL195UH070XE36B 8268322 14ACX-030-230A TXV 28,000 15.10 12.50 C35-24B EL296UH045XE36B 8268321 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 145 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-030-230A TXV 28,000 15.00 12.50 C35-24B EL296UH070XE36B 8268326 14ACX-030-230A TXV 28,000 15.10 12.50 C35-24B EL296UH070XV36B 8268323 14ACX-030-230A TXV 28,000 15.50 12.50 C35-24B SL280UH090V36B 8268325 14ACX-030-230A TXV 28,000 15.10 12.50 C35-24B SLP98UH070XV36B 8268324 14ACX-030-230A TXV 28,000 15.10 12.50 C35-30/36A EL180UH045E36A 8268346 14ACX-030-230A TXV 28,000 15.10 12.50 C35-30/36A EL180UH045XE36A 8268347 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30/36A SL280UH070V36A 8268344 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30/36A SL280UH070XV36A 8268345 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30/36B EL180UH070E36B 8268350 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30/36B EL180UH070XE36B 8268351 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30/36B EL180UH090E48B 8268352 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30/36B EL180UH090XE48B 8268358 14ACX-030-230A TXV 28,000 15.10 12.50 C35-30/36B EL195UH045XE36B 8268353 14ACX-030-230A TXV 28,000 15.10 12.50 C35-30/36B EL195UH070XE36B 8268355 14ACX-030-230A TXV 28,000 15.10 12.50 C35-30/36B EL296UH045XE36B 8268354 14ACX-030-230A TXV 27,800 15.10 12.50 C35-30/36B EL296UH045XV36B 8268359 14ACX-030-230A TXV 28,000 15.10 12.50 C35-30/36B EL296UH070XE36B 8268356 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30/36B EL296UH070XV36B 8268348 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30/36B SL280UH090V36B 8268349 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30/36B SLP98UH070XV36B 8268357 14ACX-030-230A TXV 28,000 15.10 12.50 C35-30/36C EL195UH090XE48C 8268363 14ACX-030-230A TXV 28,000 15.10 12.50 C35-30/36C EL296UH090XE48C 8268360 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30/36C EL296UH090XV36C 8268361 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30/36C SLP98UH090XV36C 8268362 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30A EL180UH045E36A 8268329 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30A EL180UH045XE36A 8268330 14ACX-030-230A TXV 28,000 16.00 13.00 C35-30A SL280UH070V36A 8268331 14ACX-030-230A TXV 28,000 16.00 13.00 C35-30A SL280UH070XV36A 8268328 14ACX-030-230A TXV 28,000 14.25 12.20 C35-30A 8268327 14ACX-030-230A TXV 28,000 16.00 13.00 C35-30B EL180UH070E36B 8268334 14ACX-030-230A TXV 28,000 16.00 13.00 C35-30B EL180UH070XE36B 8268342 14ACX-030-230A TXV 28,000 16.00 13.00 C35-30B EL180UH090E48B 8268335 14ACX-030-230A TXV 28,000 16.00 13.00 C35-30B EL180UH090XE48B 8268336 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30B EL195UH045XE36B 8268337 14ACX-030-230A TXV 28,000 15.10 12.50 C35-30B EL195UH070XE36B 8268339 14ACX-030-230A TXV 28,000 15.50 12.50 C35-30B EL296UH045XE36B 8268338 14ACX-030-230A TXV 28,000 15.10 12.50 C35-30B EL296UH070XE36B 8268343 14ACX-030-230A TXV 28,000 16.00 13.00 C35-30B EL296UH070XV36B 8268340 14ACX-030-230A TXV 28,000 16.00 13.00 C35-30B SL280UH090V36B 8268333 14ACX-030-230A TXV 28,000 16.00 13.00 C35-30B SLP98UH070XV36B 8268341 14ACX-030-230A TXV 28,000 14.25 12.20 C35-30B 8268332 14ACX-030-230A TXV 28,000 16.00 13.00 C35-36A EL180UH045E36A 8268368 14ACX-030-230A TXV 28,000 16.00 13.00 C35-36A EL180UH045XE36A 8268367 14ACX-030-230A TXV 28,000 16.00 13.00 C35-36A SL280UH070V36A 8268365 14ACX-030-230A TXV 28,000 16.00 13.00 C35-36A SL280UH070XV36A 8268366 14ACX-030-230A TXV 28,000 14.50 12.20 C35-36A 8268364 14ACX-030-230A TXV 28,000 16.00 13.00 C35-36B EL180UH070E36B 8268371 14ACX-030-230A TXV 28,000 16.00 13.00 C35-36B EL180UH070XE36B 8268372 14ACX-030-230A TXV 28,000 16.00 13.00 C35-36B EL180UH090E48B 8268373 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 146 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-030-230A TXV 28,000 16.00 13.00 C35-36B EL180UH090XE48B 8268380 14ACX-030-230A TXV 28,000 15.50 12.50 C35-36B EL195UH045XE36B 8268374 14ACX-030-230A TXV 28,000 15.50 12.50 C35-36B EL195UH070XE36B 8268376 14ACX-030-230A TXV 28,000 15.50 12.50 C35-36B EL296UH045XE36B 8268375 14ACX-030-230A TXV 28,000 15.50 12.50 C35-36B EL296UH045XV36B 8268378 14ACX-030-230A TXV 28,000 15.50 12.50 C35-36B EL296UH070XE36B 8268377 14ACX-030-230A TXV 28,000 16.00 13.00 C35-36B EL296UH070XV36B 8268381 14ACX-030-230A TXV 28,000 16.00 13.00 C35-36B SL280UH090V36B 8268370 14ACX-030-230A TXV 28,000 16.00 13.00 C35-36B SLP98UH070XV36B 8268379 14ACX-030-230A TXV 28,000 14.50 12.20 C35-36B 8268369 14ACX-030-230A TXV 28,000 16.00 13.00 C35-48B EL180UH070E36B 8268384 14ACX-030-230A TXV 28,000 16.00 13.00 C35-48B EL180UH070XE36B 8268385 14ACX-030-230A TXV 28,000 16.00 13.00 C35-48B EL180UH090E48B 8268386 14ACX-030-230A TXV 28,000 16.00 13.00 C35-48B EL180UH090XE48B 8268393 14ACX-030-230A TXV 28,000 15.50 12.50 C35-48B EL195UH045XE36B 8268387 14ACX-030-230A TXV 28,000 15.50 12.50 C35-48B EL195UH070XE36B 8268389 14ACX-030-230A TXV 28,000 15.50 12.50 C35-48B EL296UH045XE36B 8268388 14ACX-030-230A TXV 28,000 15.50 12.50 C35-48B EL296UH045XV36B 8268391 14ACX-030-230A TXV 28,000 15.50 12.50 C35-48B EL296UH070XE36B 8268390 14ACX-030-230A TXV 28,000 16.00 13.00 C35-48B EL296UH070XV36B 8268394 14ACX-030-230A TXV 28,000 16.00 13.00 C35-48B SL280UH090V36B 8268383 14ACX-030-230A TXV 28,000 16.00 13.00 C35-48B SLP98UH070XV36B 8268392 14ACX-030-230A TXV 28,000 14.50 12.20 C35-48B 8268382 14ACX-030-230A TXV 28,000 16.00 13.00 C35-48C EL195UH090XE48C 8268396 14ACX-030-230A TXV 28,000 16.00 13.00 C35-48C EL296UH090XE48C 8268397 14ACX-030-230A TXV 28,000 16.00 13.00 C35-48C EL296UH090XV36C 8268398 14ACX-030-230A TXV 28,000 16.00 13.00 C35-48C EL296UH090XV48C 8268400 14ACX-030-230A TXV 28,000 16.00 13.00 C35-48C SLP98UH090XV36C 8268399 14ACX-030-230A TXV 28,000 16.00 13.00 C35-48C SLP98UH090XV48C 8268401 14ACX-030-230A TXV 28,000 14.50 12.20 C35-48C 8268395 14ACX-030-230A TXV 28,600 16.00 13.00 CBA27UHE-030 10259376 14ACX-030-230A TXV 28,600 16.00 13.00 CBA27UHE-036 10259377 14ACX-030-230A TXV 28,000 14.50 12.20 CBX25UH-036 7509920 14ACX-030-230A TXV 28,000 15.10 12.50 CBX25UHV-030 7509921 14ACX-030-230A TXV 28,000 15.10 12.50 CBX25UHV-036 7509922 14ACX-030-230A TXV 28,000 16.00 13.00 CBX27UH-030 7509923 14ACX-030-230A TXV 28,000 16.00 13.00 CBX27UH-036 7509924 14ACX-030-230A TXV 28,000 15.00 12.50 CBX32M-030 7509925 14ACX-030-230A TXV 28,000 15.00 12.50 CBX32M-036 7509926 14ACX-030-230A TXV 28,000 14.50 12.50 CBX32MV-024/030 7509927 14ACX-030-230A TXV 28,000 15.10 12.50 CBX32MV-036 7509928 14ACX-030-230A TXV 28,000 15.10 12.50 CBX40UHV-030 7509929 14ACX-030-230A TXV 28,000 15.50 12.50 CBX40UHV-036 7513089 14ACX-030-230A TXV 26,800 15.00 12.50 CH23-31 EL180UH070E36B 7513090 14ACX-030-230A TXV 26,800 15.00 12.50 CH23-31 EL180UH070XE36B 7513091 14ACX-030-230A TXV 26,600 14.25 12.20 CH23-31 EL195UH045XE36B 7513281 14ACX-030-230A TXV 26,600 14.25 12.20 CH23-31 EL195UH070XE36B 7513285 14ACX-030-230A TXV 26,600 14.25 12.20 CH23-31 EL296UH045XE36B 7513282 14ACX-030-230A TXV 26,600 14.50 12.20 CH23-31 EL296UH045XV36B 7509930 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 147 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-030-230A TXV 26,600 14.25 12.20 CH23-31 EL296UH070XE36B 7513286 14ACX-030-230A TXV 26,800 14.50 12.50 CH23-31 EL296UH070XV36B 7509932 14ACX-030-230A TXV 26,800 15.10 12.50 CH23-31 SL280UH090V36B 7509931 14ACX-030-230A TXV 26,800 14.50 12.50 CH23-31 SLP98UH070XV36B 7509933 14ACX-030-230A TXV 28,000 15.50 12.50 CH23-41 EL180UH045E36A 7509936 14ACX-030-230A TXV 28,000 15.50 12.50 CH23-41 EL180UH045XE36A 7509937 14ACX-030-230A TXV 28,000 15.50 12.50 CH23-41 EL180UH070E36B 7509938 14ACX-030-230A TXV 28,000 15.50 12.50 CH23-41 EL180UH070XE36B 7509939 14ACX-030-230A TXV 28,000 16.00 13.00 CH23-41 EL180UH090E48B 7509940 14ACX-030-230A TXV 28,000 16.00 13.00 CH23-41 EL180UH090XE48B 7509941 14ACX-030-230A TXV 28,000 15.10 12.50 CH23-41 EL195UH045XE36B 7509942 14ACX-030-230A TXV 28,000 15.10 12.50 CH23-41 EL195UH070XE36B 7509944 14ACX-030-230A TXV 28,000 15.10 12.50 CH23-41 EL296UH045XE36B 7509943 14ACX-030-230A TXV 28,000 15.10 12.50 CH23-41 EL296UH045XV36B 7509946 14ACX-030-230A TXV 28,000 15.10 12.50 CH23-41 EL296UH070XE36B 7509945 14ACX-030-230A TXV 28,000 15.50 12.50 CH23-41 EL296UH070XV36B 7509947 14ACX-030-230A TXV 28,000 16.00 13.00 CH23-41 SL280UH090V36B 7509935 14ACX-030-230A TXV 28,000 15.50 12.50 CH23-41 SLP98UH070XV36B 7509948 14ACX-030-230A TXV 27,400 15.00 12.50 CH33-19 EL180UH045E36A 7509949 14ACX-030-230A TXV 27,400 15.00 12.50 CH33-19 EL180UH045XE36A 7509950 14ACX-030-230A TXV 27,600 15.10 12.50 CH33-19 SL280UH070V36A 7509951 14ACX-030-230A TXV 27,600 15.10 12.50 CH33-19 SL280UH070XV36A 7509952 14ACX-030-230A TXV 27,400 15.00 12.50 CH33-24/30 EL180UH045E36A 7513094 14ACX-030-230A TXV 27,400 15.00 12.50 CH33-24/30 EL180UH045XE36A 7513095 14ACX-030-230A TXV 27,400 15.00 12.50 CH33-24/30 SL280UH070V36A 7513092 14ACX-030-230A TXV 27,400 15.00 12.50 CH33-24/30 SL280UH070XV36A 7513093 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-25A EL180UH045E36A 7509957 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-25A EL180UH045XE36A 7509958 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-25A SL280UH070V36A 7509955 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-25A SL280UH070XV36A 7509956 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-25B EL180UH070E36B 7509961 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-25B EL180UH070XE36B 7509962 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-25B EL180UH090E48B 7509963 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-25B EL180UH090XE48B 7509964 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-25B EL195UH045XE36B 7509965 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-25B EL195UH070XE36B 7509967 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-25B EL296UH045XE36B 7513096 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-25B EL296UH045XV36B 7509966 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-25B EL296UH070XE36B 7509968 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-25B EL296UH070XV36B 7509969 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-25B SL280UH090V36B 9150358 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-25B SLP98UH070XV36B 7509970 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-31A EL180UH045E36A 7509975 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-31A EL180UH045XE36A 7509976 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-31A SL280UH070V36A 7509973 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-31A SL280UH070XV36A 7509974 14ACX-030-230A TXV 28,000 14.25 12.20 CH33-31A 7509972 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-31B EL180UH070E36B 7509980 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-31B EL180UH070XE36B 7509981 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 148 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-31B EL180UH090E48B 7509982 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-31B EL180UH090XE48B 7509983 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-31B EL195UH045XE36B 7509984 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-31B EL195UH070XE36B 7509986 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-31B EL296UH045XE36B 7509985 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-31B EL296UH045XV36B 7509988 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-31B EL296UH070XE36B 7509987 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-31B EL296UH070XV36B 7509989 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-31B SL280UH090V36B 7509979 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-31B SLP98UH070XV36B 7509990 14ACX-030-230A TXV 28,000 14.50 12.20 CH33-31B 7509978 14ACX-030-230A TXV 27,800 15.10 12.50 CH33-36A EL180UH045E36A 7509992 14ACX-030-230A TXV 27,800 15.10 12.50 CH33-36A EL180UH045XE36A 7509993 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-36A SL280UH070V36A 7509994 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-36A SL280UH070XV36A 7509995 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-36B EL180UH070E36B 7509999 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-36B EL180UH070XE36B 7510000 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-36B EL180UH090E48B 7510001 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-36B EL180UH090XE48B 7510002 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-36B EL195UH045XE36B 7510003 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-36B EL195UH070XE36B 7510005 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-36B EL296UH045XE36B 7510004 14ACX-030-230A TXV 27,800 15.10 12.50 CH33-36B EL296UH045XV36B 7509997 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-36B EL296UH070XE36B 7510006 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-36B SL280UH090V36B 7509998 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-36B SLP98UH070XV36B 7510008 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-36C EL195UH090XE48C 7510011 14ACX-030-230A TXV 28,000 15.10 12.50 CH33-36C EL296UH090XE48C 7510012 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-36C EL296UH090XV36C 7614670 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-36C SLP98UH090XV36C 7510014 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-42 EL180UH070E36B 7513099 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-42 EL180UH070XE36B 7513100 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-42 EL180UH090E48B 7513101 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-42 EL180UH090XE48B 7513102 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-42 EL195UH045XE36B 7513103 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-42 EL195UH070XE36B 7513105 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-42 EL296UH045XE36B 7513104 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-42 EL296UH045XV36B 7513107 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-42 EL296UH070XE36B 7513106 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-42 EL296UH070XV36B 7513108 14ACX-030-230A TXV 28,000 15.50 12.50 CH33-42 SLP98UH070XV36B 7513109 14ACX-030-230A TXV 28,000 14.25 12.20 CH33-42 7513097 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43B EL180UH070E36B 7510019 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43B EL180UH070XE36B 7510020 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43B EL180UH090E48B 7510021 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43B EL180UH090XE48B 7510022 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43B EL195UH045XE36B 7510023 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43B EL195UH070XE36B 7510025 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43B EL296UH045XE36B 7510024 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 149 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43B EL296UH045XV36B 7510027 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43B EL296UH070XE36B 7510026 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43B EL296UH070XV36B 7510028 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43B SL280UH090V36B 7510018 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43B SLP98UH070XV36B 7510029 14ACX-030-230A TXV 28,000 14.50 12.50 CH33-43B 7510017 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43C EL195UH090XE48C 7510031 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43C EL296UH090XE48C 7510032 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43C EL296UH090XV36C 7510033 14ACX-030-230A TXV 28,000 16.00 13.00 CH33-43C SLP98UH090XV36C 7510034 14ACX-030-230A TXV 28,000 14.50 12.20 CH33-43C 7510030 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-24B EL180UH070E36B 7510061 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-30A EL180UH045E36A 7510038 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-30A EL180UH045XE36A 7510039 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-30A SL280UH070V36A 7510036 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-30A SL280UH070XV36A 7510037 14ACX-030-230A TXV 28,000 14.25 12.20 CH35-30A 7565653 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-30B EL180UH070E36B 7510043 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-30B EL180UH070XE36B 7510044 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-30B EL180UH090E48B 7510045 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-30B EL180UH090XE48B 7510046 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-30B EL195UH045XE36B 7510047 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-30B EL195UH070XE36B 7510049 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-30B EL296UH045XE36B 7510051 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-30B EL296UH045XV36B 7510048 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-30B EL296UH070XE36B 7510050 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-30B EL296UH070XV36B 7510052 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-30B SL280UH090V36B 7622670 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-30B SLP98UH070XV36B 7510053 14ACX-030-230A TXV 28,000 14.50 12.20 CH35-30B 7510041 14ACX-030-230A TXV 28,000 15.10 12.50 CH35-36A EL180UH045E36A 7510057 14ACX-030-230A TXV 28,000 15.10 12.50 CH35-36A EL180UH045XE36A 7510058 14ACX-030-230A TXV 28,000 15.10 12.50 CH35-36A SL280UH070V36A 7510055 14ACX-030-230A TXV 28,000 15.10 12.50 CH35-36A SL280UH070XV36A 7510056 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-36B EL180UH070E36B 7510062 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-36B EL180UH070XE36B 7614647 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-36B EL180UH090E48B 7510060 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-36B EL180UH090XE48B 7614648 14ACX-030-230A TXV 28,000 15.10 12.50 CH35-36B EL195UH045XE36B 7510065 14ACX-030-230A TXV 28,000 15.10 12.50 CH35-36B EL195UH070XE36B 7510067 14ACX-030-230A TXV 28,000 15.10 12.50 CH35-36B EL296UH045XE36B 7510066 14ACX-030-230A TXV 28,000 15.10 12.50 CH35-36B EL296UH045XV36B 7510069 14ACX-030-230A TXV 28,000 15.10 12.50 CH35-36B EL296UH070XE36B 7510068 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-36B EL296UH070XV36B 7510070 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-36B SLP98UH070XV36B 7510071 14ACX-030-230A TXV 28,000 15.10 12.50 CH35-36C EL195UH090XE48C 7510074 14ACX-030-230A TXV 28,000 15.10 12.50 CH35-36C EL296UH090XE48C 7510075 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-36C EL296UH090XV36C 7510076 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-36C SLP98UH090XV36C 7510077 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 150 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-42B EL180UH070E36B 7510080 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-42B EL180UH070XE36B 7510081 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-42B EL180UH090E48B 7510082 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-42B EL180UH090XE48B 7510083 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-42B EL195UH045XE36B 7510084 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-42B EL195UH070XE36B 7510087 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-42B EL296UH045XE36B 7510088 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-42B EL296UH045XV36B 7510085 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-42B EL296UH070XE36B 7510086 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-42B EL296UH070XV36B 7510089 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-42B SL280UH090V36B 7510079 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-42B SLP98UH070XV36B 7510090 14ACX-030-230A TXV 28,000 14.50 12.50 CH35-42B 7510078 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-42C EL195UH090XE48C 7510092 14ACX-030-230A TXV 28,000 15.50 12.50 CH35-42C EL296UH090XE48C 7510093 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-42C EL296UH090XV36C 7510094 14ACX-030-230A TXV 28,000 16.00 13.00 CH35-42C SLP98UH090XV36C 7510095 14ACX-030-230A TXV 28,000 14.50 12.20 CH35-42C 7510091 14ACX-030-230A TXV 26,800 14.50 12.20 CR33-24A EL180DF045E36A 7510096 14ACX-030-230A TXV 26,800 14.25 12.20 CR33-24B EL180DF070E36B 7510100 14ACX-030-230A TXV 26,600 14.25 12.20 CR33-24B EL296DF045XV36B 7513111 14ACX-030-230A TXV 26,600 14.25 12.20 CR33-24B SL280DF090V48B 7510097 14ACX-030-230A TXV 26,600 14.25 12.20 CR33-24B SLP98DF070XV36B 7513110 14ACX-030-230A TXV 28,000 15.10 12.50 CR33-30/36A EL180DF045E36A 7510104 14ACX-030-230A TXV 28,000 15.50 12.50 CR33-30/36A SL280DF070V36A 7510103 14ACX-030-230A TXV 28,000 15.50 12.50 CR33-30/36B EL180DF070E36B 7510108 14ACX-030-230A TXV 28,000 15.50 12.50 CR33-30/36B EL180DF090E48B 7510109 14ACX-030-230A TXV 28,000 15.10 12.50 CR33-30/36B EL195DF045XE36B 7510110 14ACX-030-230A TXV 28,000 15.50 12.50 CR33-30/36B EL195DF070XE48B 7510112 14ACX-030-230A TXV 28,000 15.10 12.50 CR33-30/36B EL296DF045XE36B 7510111 14ACX-030-230A TXV 28,000 15.50 12.50 CR33-30/36B EL296DF045XV36B 7510114 14ACX-030-230A TXV 28,000 15.50 12.50 CR33-30/36B EL296DF070XE48B 7510113 14ACX-030-230A TXV 28,000 15.10 12.50 CR33-30/36B EL296DF070XV48B 7614661 14ACX-030-230A TXV 28,000 15.50 12.50 CR33-30/36B SL280DF090V48B 7622672 14ACX-030-230A TXV 28,000 15.50 12.50 CR33-30/36B SLP98DF070XV36B 7510116 14ACX-030-230A TXV 28,000 16.00 13.00 CR33-30/36C SLP98DF090XV36C 7510119 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-25A EL180UH045E36A 7510123 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-25A EL180UH045XE36A 7510124 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-25A SL280UH070V36A 7510121 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-25A SL280UH070XV36A 7510122 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-25B EL180UH070E36B 7510129 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-25B EL180UH070XE36B 7510130 14ACX-030-230A TXV 27,800 15.50 12.50 CX34-25B EL180UH090E48B 7510126 14ACX-030-230A TXV 27,800 15.50 12.50 CX34-25B EL180UH090XE48B 7510127 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-25B EL195UH045XE36B 7510131 14ACX-030-230A TXV 28,000 15.00 12.50 CX34-25B EL195UH070XE36B 7510133 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-25B EL296UH045XE36B 7510132 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-25B EL296UH045XV36B 7510135 14ACX-030-230A TXV 28,000 15.00 12.50 CX34-25B EL296UH070XE36B 7510134 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 151 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-25B EL296UH070XV36B 7510136 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-25B SL280UH090V36B 7510128 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-25B SLP98UH070XV36B 7510137 14ACX-030-230A TXV 27,400 15.00 12.50 CX34-30A EL180UH045E36A 7510145 14ACX-030-230A TXV 27,400 15.00 12.50 CX34-30A EL180UH045XE36A 7510146 14ACX-030-230A TXV 27,400 15.00 12.50 CX34-30A SL280UH070V36A 7510143 14ACX-030-230A TXV 27,400 15.00 12.50 CX34-30A SL280UH070XV36A 7510144 14ACX-030-230A TXV 27,400 15.10 12.50 CX34-30B EL180UH070E36B 7510147 14ACX-030-230A TXV 27,400 15.10 12.50 CX34-30B EL180UH070XE36B 7510148 14ACX-030-230A TXV 27,200 15.10 12.50 CX34-30B EL180UH090E48B 7510138 14ACX-030-230A TXV 27,200 15.10 12.50 CX34-30B EL180UH090XE48B 7510139 14ACX-030-230A TXV 27,200 14.50 12.50 CX34-30B EL195UH045XE36B 7510140 14ACX-030-230A TXV 27,400 14.50 12.50 CX34-30B EL195UH070XE36B 7510149 14ACX-030-230A TXV 27,200 14.50 12.50 CX34-30B EL296UH045XE36B 7510141 14ACX-030-230A TXV 27,200 14.50 12.50 CX34-30B EL296UH045XV36B 7510142 14ACX-030-230A TXV 27,400 14.50 12.50 CX34-30B EL296UH070XE36B 7510150 14ACX-030-230A TXV 27,400 15.00 12.50 CX34-30B EL296UH070XV36B 7510151 14ACX-030-230A TXV 27,600 15.10 12.50 CX34-30B SL280UH090V36B 7510153 14ACX-030-230A TXV 27,400 15.00 12.50 CX34-30B SLP98UH070XV36B 7510152 14ACX-030-230A TXV 27,400 15.10 12.50 CX34-30C SLP98UH090XV36C 7513112 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-31A EL180UH045E36A 7510157 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-31A EL180UH045XE36A 7510158 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-31A SL280UH070V36A 7510155 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-31A SL280UH070XV36A 7510156 14ACX-030-230A TXV 28,000 14.25 12.20 CX34-31A 7510154 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-31B EL180UH070E36B 7510161 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-31B EL180UH070XE36B 7510162 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-31B EL180UH090E48B 7510163 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-31B EL180UH090XE48B 7510164 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-31B EL195UH045XE36B 7510165 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-31B EL195UH070XE36B 7510167 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-31B EL296UH045XE36B 7510166 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-31B EL296UH045XV36B 7510169 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-31B EL296UH070XE36B 7510168 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-31B EL296UH070XV36B 7510170 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-31B SL280UH090V36B 7510160 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-31B SLP98UH070XV36B 8083368 14ACX-030-230A TXV 28,000 14.25 12.20 CX34-31B 7510159 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-36A EL180UH045E36A 7510175 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-36A EL180UH045XE36A 7510176 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-36A SL280UH070V36A 7510173 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-36A SL280UH070XV36A 7510174 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-36B EL180UH070E36B 7510180 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-36B EL180UH070XE36B 7510181 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-36B EL180UH090E48B 7510182 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-36B EL180UH090XE48B 7510183 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-36B EL195UH045XE36B 7510184 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-36B EL195UH070XE36B 7510186 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-36B EL296UH045XE36B 7510185 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 152 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-030-230A TXV 27,800 15.10 12.50 CX34-36B EL296UH045XV36B 7510178 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-36B EL296UH070XE36B 7510187 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-36B EL296UH070XV36B 7510188 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-36B SL280UH090V36B 7510179 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-36B SLP98UH070XV36B 7510189 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-36C EL195UH090XE48C 7510190 14ACX-030-230A TXV 28,000 15.10 12.50 CX34-36C EL296UH090XE48C 7510191 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-36C EL296UH090XV36C 7510192 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-36C SLP98UH090XV36C 7510193 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-38A EL180UH045E36A 7510197 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-38A EL180UH045XE36A 7510198 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-38A SL280UH070V36A 7510195 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-38A SL280UH070XV36A 7510196 14ACX-030-230A TXV 28,000 14.50 12.20 CX34-38A 7510194 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-38B EL180UH070E36B 7510201 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-38B EL180UH070XE36B 7510202 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-38B EL180UH090E48B 7510203 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-38B EL180UH090XE48B 7510204 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-38B EL195UH045XE36B 7510205 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-38B EL195UH070XE36B 7510207 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-38B EL296UH045XE36B 7510206 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-38B EL296UH045XV36B 7510209 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-38B EL296UH070XE36B 7510208 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-38B EL296UH070XV36B 7510210 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-38B SL280UH090V36B 7510200 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-38B SLP98UH070XV36B 7510211 14ACX-030-230A TXV 28,000 14.50 12.20 CX34-38B 7510199 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-42 EL180UH070E36B 7513115 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-42 EL180UH070XE36B 7513116 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-42 EL180UH090E48B 7513117 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-42 EL180UH090XE48B 7513118 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-42 EL195UH045XE36B 7513119 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-42 EL195UH070XE36B 7513121 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-42 EL296UH045XE36B 7513120 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-42 EL296UH045XV36B 7513123 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-42 EL296UH070XE36B 7513122 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-42 EL296UH070XV36B 7513124 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-42 SL280UH090V36B 7513114 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-42 SLP98UH070XV36B 7513125 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-43B EL180UH070E36B 7510214 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-43B EL180UH070XE36B 7510215 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-43B EL180UH090E48B 7510216 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-43B EL180UH090XE48B 7510217 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-43B EL195UH045XE36B 7510218 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-43B EL195UH070XE36B 7510220 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-43B EL296UH045XE36B 7510219 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-43B EL296UH045XV36B 7510222 14ACX-030-230A TXV 28,000 15.50 12.50 CX34-43B EL296UH070XE36B 7510221 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-43B EL296UH070XV36B 7510223 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 153 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-43B SL280UH090V36B 7510213 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-43B SLP98UH070XV36B 7510224 14ACX-030-230A TXV 28,000 14.50 12.20 CX34-43B 7510212 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-43C EL195UH090XE48C 7510226 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-43C EL296UH090XE48C 7510227 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-43C EL296UH090XV36C 7510228 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-43C EL296UH090XV48C 7513126 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-43C SLP98UH090XV36C 7510229 14ACX-030-230A TXV 28,000 16.00 13.00 CX34-43C SLP98UH090XV48C 7513127 14ACX-030-230A TXV 28,000 14.50 12.20 CX34-43C 7510225 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-24A EL180UH045E36A 8268404 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-24A EL180UH045XE36A 8268405 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-24A SL280UH070V36A 8268402 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-24A SL280UH070XV36A 8268403 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-24B EL180UH070E36B 8268411 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-24B EL180UH070XE36B 8268406 14ACX-030-230A TXV 27,800 15.50 12.50 CX35-24B EL180UH090E48B 8268408 14ACX-030-230A TXV 27,800 15.50 12.50 CX35-24B EL180UH090XE48B 8268409 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-24B EL195UH045XE36B 8268412 14ACX-030-230A TXV 28,000 15.00 12.50 CX35-24B EL195UH070XE36B 8268414 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-24B EL296UH045XE36B 8268413 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-24B EL296UH045XV36B 8268416 14ACX-030-230A TXV 28,000 15.00 12.50 CX35-24B EL296UH070XE36B 8268415 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-24B EL296UH070XV36B 8268407 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-24B SL280UH090V36B 8268410 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-24B SLP98UH070XV36B 8268417 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-30/36A EL180UH045E36A 8268436 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-30/36A EL180UH045XE36A 8268439 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30/36A SL280UH070V36A 8268437 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30/36A SL280UH070XV36A 8268438 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30/36B EL180UH070E36B 8268446 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30/36B EL180UH070XE36B 8268440 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30/36B EL180UH090E48B 8268441 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30/36B EL180UH090XE48B 8268447 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-30/36B EL195UH045XE36B 8268448 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-30/36B EL195UH070XE36B 8268450 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-30/36B EL296UH045XE36B 8268449 14ACX-030-230A TXV 27,800 15.10 12.50 CX35-30/36B EL296UH045XV36B 8268444 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-30/36B EL296UH070XE36B 8268442 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30/36B EL296UH070XV36B 8268443 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30/36B SL280UH090V36B 8268445 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30/36B SLP98UH070XV36B 8268451 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-30/36C EL195UH090XE48C 8268453 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-30/36C EL296UH090XE48C 8268454 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30/36C EL296UH090XV36C 8268455 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30/36C SLP98UH090XV36C 8268452 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30A EL180UH045E36A 8268421 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30A EL180UH045XE36A 8268422 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-30A SL280UH070V36A 8268419 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 154 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-30A SL280UH070XV36A 8268420 14ACX-030-230A TXV 28,000 14.25 12.20 CX35-30A 8268418 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-30B EL180UH070E36B 8268428 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-30B EL180UH070XE36B 8268425 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-30B EL180UH090E48B 8268429 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-30B EL180UH090XE48B 8268430 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30B EL195UH045XE36B 8268431 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-30B EL195UH070XE36B 8268433 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30B EL296UH045XE36B 8268432 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-30B EL296UH045XV36B 8268434 14ACX-030-230A TXV 28,000 15.10 12.50 CX35-30B EL296UH070XE36B 8268426 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-30B EL296UH070XV36B 8268435 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-30B SL280UH090V36B 8268427 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-30B SLP98UH070XV36B 8268424 14ACX-030-230A TXV 28,000 14.25 12.20 CX35-30B 8268423 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-36A EL180UH045E36A 8268459 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-36A EL180UH045XE36A 8268460 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-36A SL280UH070V36A 8268457 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-36A SL280UH070XV36A 8268458 14ACX-030-230A TXV 28,000 14.50 12.20 CX35-36A 8268456 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-36B EL180UH070E36B 8268462 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-36B EL180UH070XE36B 8268463 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-36B EL180UH090E48B 8268467 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-36B EL180UH090XE48B 8268468 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-36B EL195UH045XE36B 8268469 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-36B EL195UH070XE36B 8268464 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-36B EL296UH045XE36B 8268470 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-36B EL296UH045XV36B 8268471 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-36B EL296UH070XE36B 8268465 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-36B EL296UH070XV36B 8268472 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-36B SL280UH090V36B 8268466 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-36B SLP98UH070XV36B 8268473 14ACX-030-230A TXV 28,000 14.50 12.20 CX35-36B 8268461 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-48B EL180UH070E36B 8268475 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-48B EL180UH070XE36B 8268476 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-48B EL180UH090E48B 8268480 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-48B EL180UH090XE48B 8268481 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-48B EL195UH045XE36B 8268482 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-48B EL195UH070XE36B 8268477 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-48B EL296UH045XE36B 8268483 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-48B EL296UH045XV36B 8268484 14ACX-030-230A TXV 28,000 15.50 12.50 CX35-48B EL296UH070XE36B 8268478 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-48B EL296UH070XV36B 8268485 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-48B SL280UH090V36B 8268479 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-48B SLP98UH070XV36B 8268486 14ACX-030-230A TXV 28,000 14.50 12.20 CX35-48B 8268474 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-48C EL195UH090XE48C 8268490 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-48C EL296UH090XE48C 8268488 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-48C EL296UH090XV36C 8268489 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 155 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-48C EL296UH090XV48C 8268492 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-48C SLP98UH090XV36C 8268491 14ACX-030-230A TXV 28,000 16.00 13.00 CX35-48C SLP98UH090XV48C 8268493 14ACX-030-230A TXV 28,000 14.50 12.20 CX35-48C 8268487 14ACX-036-230A RFC 34,000 14.25 12.20 C33-43 7513149 14ACX-036-230A RFC 34,400 14.25 12.20 C33-49 7513151 14ACX-036-230A RFC 34,000 14.25 12.20 C33-50/60C 7510368 14ACX-036-230A RFC 34,400 14.00 12.20 C35-49C 8471018 14ACX-036-230A RFC 34,000 14.00 12.20 C35-50/60C 8471020 14ACX-036-230A RFC 33,800 14.00 12.20 CH33-31B 7510456 14ACX-036-230A RFC 34,600 14.50 12.20 CH33-43B 7510507 14ACX-036-230A RFC 34,000 14.25 12.20 CH33-44/48B 7510541 14ACX-036-230A RFC 34,000 14.25 12.20 CH33-48 7513192 14ACX-036-230A RFC 34,600 14.50 12.20 CH33-49 7513193 14ACX-036-230A RFC 34,400 14.25 12.20 CH33-50/60C 7510594 14ACX-036-230A TXV 34,200 15.10 12.50 C33-31A EL180UH045E36A 7510237 14ACX-036-230A TXV 34,200 15.10 12.50 C33-31A EL180UH045XE36A 7510238 14ACX-036-230A TXV 34,400 15.10 12.50 C33-31A SL280UH070V36A 7510235 14ACX-036-230A TXV 34,400 15.10 12.50 C33-31A SL280UH070XV36A 7510236 14ACX-036-230A TXV 34,400 15.00 12.50 C33-31B EL180UH070E36B 7510244 14ACX-036-230A TXV 34,400 15.00 12.50 C33-31B EL180UH070XE36B 7510245 14ACX-036-230A TXV 34,400 15.50 12.50 C33-31B EL180UH090E48B 7510246 14ACX-036-230A TXV 34,400 15.50 12.50 C33-31B EL180UH090XE48B 7510247 14ACX-036-230A TXV 34,000 14.50 12.20 C33-31B EL195UH045XE36B 7510248 14ACX-036-230A TXV 34,000 15.10 12.50 C33-31B EL195UH070XE36B 7510250 14ACX-036-230A TXV 34,000 14.50 12.20 C33-31B EL296UH045XE36B 7510249 14ACX-036-230A TXV 34,200 15.10 12.50 C33-31B EL296UH045XV36B 7510252 14ACX-036-230A TXV 34,000 15.10 12.50 C33-31B EL296UH070XE36B 7510251 14ACX-036-230A TXV 34,200 15.10 12.50 C33-31B EL296UH070XV36B 7510253 14ACX-036-230A TXV 34,400 15.50 12.50 C33-31B SL280UH090V36B 7510241 14ACX-036-230A TXV 34,400 15.50 12.50 C33-31B SL280UH090V48B 7510242 14ACX-036-230A TXV 34,400 15.50 12.50 C33-31B SL280UH090XV48B 7510243 14ACX-036-230A TXV 34,200 15.10 12.50 C33-31B SLP98UH070XV36B 7510254 14ACX-036-230A TXV 33,200 14.50 12.20 C33-36A EL180UH045E36A 7510258 14ACX-036-230A TXV 33,200 14.50 12.20 C33-36A EL180UH045XE36A 7510259 14ACX-036-230A TXV 33,400 15.00 12.20 C33-36A SL280UH070V36A 7510256 14ACX-036-230A TXV 33,400 15.00 12.20 C33-36A SL280UH070XV36A 7510257 14ACX-036-230A TXV 33,400 15.50 12.50 C33-36B EL180UH070E36B 7510264 14ACX-036-230A TXV 33,400 15.50 12.50 C33-36B EL180UH070XE36B 7510265 14ACX-036-230A TXV 33,400 15.10 12.50 C33-36B EL180UH090E48B 7510266 14ACX-036-230A TXV 33,400 15.10 12.50 C33-36B EL180UH090XE48B 7510267 14ACX-036-230A TXV 33,000 15.00 12.50 C33-36B EL195UH045XE36B 7510268 14ACX-036-230A TXV 33,000 15.00 12.50 C33-36B EL296UH045XE36B 7510269 14ACX-036-230A TXV 33,400 15.00 12.50 C33-36B EL296UH045XV36B 7510272 14ACX-036-230A TXV 33,400 15.00 12.50 C33-36B EL296UH070XV36B 7510273 14ACX-036-230A TXV 33,600 15.50 12.50 C33-36B SL280UH090V36B 7510261 14ACX-036-230A TXV 33,600 15.50 12.50 C33-36B SL280UH090V48B 7510262 14ACX-036-230A TXV 33,600 15.50 12.50 C33-36B SL280UH090XV48B 7510263 14ACX-036-230A TXV 33,400 15.00 12.50 C33-36B SLP98UH070XV36B 7510274 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 156 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 33,600 15.10 12.50 C33-36C EL180UH090E60C 7510276 14ACX-036-230A TXV 33,400 15.50 12.50 C33-36C EL180UH110E60C 7510277 14ACX-036-230A TXV 33,400 15.50 12.50 C33-36C EL180UH110XE60C 7510278 14ACX-036-230A TXV 33,200 15.10 12.50 C33-36C EL195UH090XE48C 7510279 14ACX-036-230A TXV 33,600 15.10 12.50 C33-36C EL195UH110XE60C 7510281 14ACX-036-230A TXV 33,200 15.10 12.50 C33-36C EL296UH090XE48C 7510280 14ACX-036-230A TXV 33,600 15.50 12.50 C33-36C EL296UH090XV36C 7510283 14ACX-036-230A TXV 33,400 15.50 12.50 C33-36C EL296UH090XV48C 7510285 14ACX-036-230A TXV 33,600 15.10 12.50 C33-36C EL296UH110XE60C 7510282 14ACX-036-230A TXV 33,600 15.50 12.50 C33-36C EL296UH110XV48C 7510287 14ACX-036-230A TXV 33,600 15.50 12.50 C33-36C SLP98UH090XV36C 7510284 14ACX-036-230A TXV 33,400 15.50 12.50 C33-36C SLP98UH090XV48C 7510286 14ACX-036-230A TXV 33,800 15.50 12.50 C33-36C SLP98UH110XV60C 7513133 14ACX-036-230A TXV 34,400 15.10 12.50 C33-38A EL180UH045E36A 7510292 14ACX-036-230A TXV 34,400 15.10 12.50 C33-38A EL180UH045XE36A 7510293 14ACX-036-230A TXV 34,600 15.50 12.50 C33-38A SL280UH070V36A 7510290 14ACX-036-230A TXV 34,600 15.50 12.50 C33-38A SL280UH070XV36A 7510291 14ACX-036-230A TXV 34,200 14.25 12.20 C33-38A 7510289 14ACX-036-230A TXV 34,600 16.00 13.00 C33-38B EL180UH070E36B 7510299 14ACX-036-230A TXV 34,600 16.00 13.00 C33-38B EL180UH070XE36B 7510300 14ACX-036-230A TXV 34,600 16.00 13.00 C33-38B EL180UH090E48B 7510301 14ACX-036-230A TXV 34,600 16.00 13.00 C33-38B EL180UH090XE48B 7510302 14ACX-036-230A TXV 34,400 15.00 12.50 C33-38B EL195UH045XE36B 7510303 14ACX-036-230A TXV 34,400 15.00 12.50 C33-38B EL195UH070XE36B 7510305 14ACX-036-230A TXV 34,400 15.00 12.50 C33-38B EL296UH045XE36B 7510304 14ACX-036-230A TXV 34,600 15.50 12.50 C33-38B EL296UH045XV36B 7510307 14ACX-036-230A TXV 34,400 15.00 12.50 C33-38B EL296UH070XE36B 7510306 14ACX-036-230A TXV 34,600 15.50 12.50 C33-38B EL296UH070XV36B 7510308 14ACX-036-230A TXV 34,800 16.00 13.00 C33-38B SL280UH090V36B 7510296 14ACX-036-230A TXV 34,800 16.00 13.00 C33-38B SL280UH090V48B 7510297 14ACX-036-230A TXV 34,800 16.00 13.00 C33-38B SL280UH090XV48B 7510298 14ACX-036-230A TXV 34,600 15.50 12.50 C33-38B SLP98UH070XV36B 7510309 14ACX-036-230A TXV 34,200 14.25 12.20 C33-38B 7510295 14ACX-036-230A TXV 33,400 15.50 12.50 C33-42 EL180UH070E36B 7513138 14ACX-036-230A TXV 33,400 15.50 12.50 C33-42 EL180UH070XE36B 7513139 14ACX-036-230A TXV 33,400 15.10 12.50 C33-42 EL180UH090E48B 7513140 14ACX-036-230A TXV 33,400 15.10 12.50 C33-42 EL180UH090XE48B 7513141 14ACX-036-230A TXV 33,000 15.00 12.50 C33-42 EL195UH045XE36B 7513142 14ACX-036-230A TXV 33,000 15.00 12.50 C33-42 EL296UH045XE36B 7513143 14ACX-036-230A TXV 33,400 15.00 12.50 C33-42 EL296UH045XV36B 7513146 14ACX-036-230A TXV 33,400 15.00 12.50 C33-42 EL296UH070XV36B 7513147 14ACX-036-230A TXV 33,600 15.50 12.50 C33-42 SL280UH090V36B 7513135 14ACX-036-230A TXV 33,600 15.50 12.50 C33-42 SL280UH090V48B 7513136 14ACX-036-230A TXV 33,600 15.50 12.50 C33-42 SL280UH090XV48B 7513137 14ACX-036-230A TXV 33,400 15.00 12.50 C33-42 SLP98UH070XV36B 7513148 14ACX-036-230A TXV 34,800 16.00 13.00 C33-43B EL180UH070E36B 7510314 14ACX-036-230A TXV 34,800 16.00 13.00 C33-43B EL180UH070XE36B 7510315 14ACX-036-230A TXV 34,800 16.00 13.00 C33-43B EL180UH090E48B 7510316 14ACX-036-230A TXV 34,800 16.00 13.00 C33-43B EL180UH090XE48B 7510317 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 157 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 34,400 15.00 12.50 C33-43B EL195UH045XE36B 7510318 14ACX-036-230A TXV 34,600 15.10 12.50 C33-43B EL195UH070XE36B 7510320 14ACX-036-230A TXV 34,400 15.00 12.50 C33-43B EL296UH045XE36B 7510319 14ACX-036-230A TXV 34,800 15.50 12.50 C33-43B EL296UH045XV36B 7510322 14ACX-036-230A TXV 34,600 15.10 12.50 C33-43B EL296UH070XE36B 7510321 14ACX-036-230A TXV 34,800 15.50 12.50 C33-43B EL296UH070XV36B 7510323 14ACX-036-230A TXV 34,800 16.00 13.00 C33-43B SL280UH090V36B 7510311 14ACX-036-230A TXV 35,000 16.00 13.00 C33-43B SL280UH090V48B 7510312 14ACX-036-230A TXV 35,000 16.00 13.00 C33-43B SL280UH090XV48B 7510313 14ACX-036-230A TXV 34,800 15.50 12.50 C33-43B SLP98UH070XV36B 7510324 14ACX-036-230A TXV 34,400 14.50 12.20 C33-43B 7510310 14ACX-036-230A TXV 34,800 16.00 13.00 C33-43C EL180UH090E60C 7510330 14ACX-036-230A TXV 34,800 16.00 13.00 C33-43C EL180UH110E60C 7510331 14ACX-036-230A TXV 34,800 16.00 13.00 C33-43C EL180UH110XE60C 7510332 14ACX-036-230A TXV 34,600 15.50 12.50 C33-43C EL195UH090XE48C 7510333 14ACX-036-230A TXV 34,800 16.00 13.00 C33-43C EL195UH110XE60C 7510335 14ACX-036-230A TXV 34,600 15.50 12.50 C33-43C EL296UH090XE48C 7510334 14ACX-036-230A TXV 34,800 16.00 13.00 C33-43C EL296UH090XV36C 7510337 14ACX-036-230A TXV 34,800 16.00 13.00 C33-43C EL296UH090XV48C 7510339 14ACX-036-230A TXV 34,800 16.00 13.00 C33-43C EL296UH110XE60C 7510336 14ACX-036-230A TXV 35,000 16.00 13.00 C33-43C EL296UH110XV48C 7510341 14ACX-036-230A TXV 35,200 16.00 13.00 C33-43C EL296UH110XV60C 7510342 14ACX-036-230A TXV 35,400 16.00 13.00 C33-43C SL280UH090V60C 7510326 14ACX-036-230A TXV 35,400 16.00 13.00 C33-43C SL280UH090XV60C 7510327 14ACX-036-230A TXV 35,200 16.00 13.00 C33-43C SL280UH110V60C 7510328 14ACX-036-230A TXV 35,200 16.00 13.00 C33-43C SL280UH110XV60C 7510329 14ACX-036-230A TXV 34,800 16.00 13.00 C33-43C SLP98UH090XV36C 7510338 14ACX-036-230A TXV 34,800 16.00 13.00 C33-43C SLP98UH090XV48C 7510340 14ACX-036-230A TXV 35,200 16.00 13.00 C33-43C SLP98UH110XV60C 7510343 14ACX-036-230A TXV 34,400 14.50 12.20 C33-43C 7510325 14ACX-036-230A TXV 34,200 16.00 13.00 C33-48B EL180UH070E36B 7510348 14ACX-036-230A TXV 34,200 16.00 13.00 C33-48B EL180UH070XE36B 7510349 14ACX-036-230A TXV 34,200 15.50 12.50 C33-48B EL180UH090E48B 7510350 14ACX-036-230A TXV 34,200 15.50 12.50 C33-48B EL180UH090XE48B 7510351 14ACX-036-230A TXV 33,800 15.10 12.50 C33-48B EL195UH045XE36B 7510352 14ACX-036-230A TXV 34,200 15.00 12.50 C33-48B EL195UH070XE36B 7510354 14ACX-036-230A TXV 33,800 15.10 12.50 C33-48B EL296UH045XE36B 7510353 14ACX-036-230A TXV 34,200 15.10 12.50 C33-48B EL296UH045XV36B 7510356 14ACX-036-230A TXV 34,200 15.00 12.50 C33-48B EL296UH070XE36B 7510355 14ACX-036-230A TXV 34,200 15.10 12.50 C33-48B EL296UH070XV36B 7510357 14ACX-036-230A TXV 34,400 16.00 13.00 C33-48B SL280UH090V36B 7510345 14ACX-036-230A TXV 34,400 16.00 13.00 C33-48B SL280UH090V48B 7510346 14ACX-036-230A TXV 34,400 16.00 13.00 C33-48B SL280UH090XV48B 7510347 14ACX-036-230A TXV 34,000 15.10 12.50 C33-48B SLP98UH070XV36B 7510358 14ACX-036-230A TXV 34,200 15.10 12.50 C33-48C EL195UH090XE48C 7510360 14ACX-036-230A TXV 34,400 15.50 12.50 C33-48C EL195UH110XE60C 7510362 14ACX-036-230A TXV 34,200 15.10 12.50 C33-48C EL296UH090XE48C 7510361 14ACX-036-230A TXV 34,400 15.50 12.50 C33-48C EL296UH090XV36C 7510364 14ACX-036-230A TXV 34,400 15.50 12.50 C33-48C EL296UH090XV48C 7510366 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 158 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 34,400 15.50 12.50 C33-48C EL296UH110XE60C 7510363 14ACX-036-230A TXV 34,400 15.50 12.50 C33-48C SLP98UH090XV36C 7510365 14ACX-036-230A TXV 34,400 15.50 12.50 C33-48C SLP98UH090XV48C 7510367 14ACX-036-230A TXV 35,200 16.00 13.00 C33-49 EL180UH090E60C 7513157 14ACX-036-230A TXV 35,000 16.00 13.00 C33-49 EL180UH110E60C 7513158 14ACX-036-230A TXV 35,000 16.00 13.00 C33-49 EL180UH110XE60C 7513159 14ACX-036-230A TXV 34,800 16.00 13.00 C33-49 EL195UH090XE48C 7513160 14ACX-036-230A TXV 35,200 16.00 13.00 C33-49 EL195UH110XE60C 7513162 14ACX-036-230A TXV 34,800 16.00 13.00 C33-49 EL296UH090XE48C 7513161 14ACX-036-230A TXV 35,200 16.00 13.00 C33-49 EL296UH090XV36C 7513164 14ACX-036-230A TXV 35,000 16.00 13.00 C33-49 EL296UH090XV48C 7513166 14ACX-036-230A TXV 35,200 16.00 13.00 C33-49 EL296UH110XE60C 7513163 14ACX-036-230A TXV 35,200 16.00 13.00 C33-49 EL296UH110XV48C 7513168 14ACX-036-230A TXV 35,600 16.00 13.00 C33-49 EL296UH110XV60C 7513169 14ACX-036-230A TXV 35,600 16.00 13.00 C33-49 SL280UH090V60C 7513153 14ACX-036-230A TXV 35,600 16.00 13.00 C33-49 SL280UH090XV60C 7513154 14ACX-036-230A TXV 35,400 16.00 13.00 C33-49 SL280UH110V60C 7513155 14ACX-036-230A TXV 35,400 16.00 13.00 C33-49 SL280UH110XV60C 7513156 14ACX-036-230A TXV 35,200 16.00 13.00 C33-49 SLP98UH090XV36C 7513165 14ACX-036-230A TXV 35,000 16.00 13.00 C33-49 SLP98UH090XV48C 7513167 14ACX-036-230A TXV 35,600 16.00 13.00 C33-49 SLP98UH110XV60C 7513170 14ACX-036-230A TXV 34,600 14.50 12.20 C33-49 7513152 14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C EL180UH090E60C 7510374 14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C EL180UH110E60C 7510375 14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C EL180UH110XE60C 7510376 14ACX-036-230A TXV 34,600 15.50 12.50 C33-50/60C EL195UH090XE48C 7510377 14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C EL195UH110XE60C 7510379 14ACX-036-230A TXV 34,600 15.50 12.50 C33-50/60C EL296UH090XE48C 7510378 14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C EL296UH090XV36C 7510381 14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C EL296UH090XV48C 7510383 14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C EL296UH110XE60C 7510380 14ACX-036-230A TXV 35,000 16.00 13.00 C33-50/60C EL296UH110XV48C 7510385 14ACX-036-230A TXV 35,200 16.00 13.00 C33-50/60C EL296UH110XV60C 7510386 14ACX-036-230A TXV 35,200 16.00 13.00 C33-50/60C SL280UH090V60C 7510370 14ACX-036-230A TXV 35,200 16.00 13.00 C33-50/60C SL280UH090XV60C 7510371 14ACX-036-230A TXV 35,000 16.00 13.00 C33-50/60C SL280UH110V60C 7510372 14ACX-036-230A TXV 35,000 16.00 13.00 C33-50/60C SL280UH110XV60C 7510373 14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C SLP98UH090XV36C 7510382 14ACX-036-230A TXV 34,800 16.00 13.00 C33-50/60C SLP98UH090XV48C 7510384 14ACX-036-230A TXV 35,200 16.00 13.00 C33-50/60C SLP98UH110XV60C 7510387 14ACX-036-230A TXV 34,200 14.50 12.20 C33-50/60C 7510369 14ACX-036-230A TXV 33,200 14.50 12.20 C35-30/36A EL180UH045E36A 8268054 14ACX-036-230A TXV 33,200 14.50 12.20 C35-30/36A EL180UH045XE36A 8268055 14ACX-036-230A TXV 33,400 15.00 12.20 C35-30/36A SL280UH070V36A 8268052 14ACX-036-230A TXV 33,400 15.00 12.20 C35-30/36A SL280UH070XV36A 8268053 14ACX-036-230A TXV 33,400 15.50 12.50 C35-30/36B EL180UH070E36B 8268061 14ACX-036-230A TXV 33,400 15.50 12.50 C35-30/36B EL180UH070XE36B 8268062 14ACX-036-230A TXV 33,400 15.10 12.50 C35-30/36B EL180UH090E48B 8268063 14ACX-036-230A TXV 33,400 15.10 12.50 C35-30/36B EL180UH090XE48B 8268064 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 159 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 33,000 15.00 12.50 C35-30/36B EL195UH045XE36B 8268065 14ACX-036-230A TXV 33,000 15.00 12.50 C35-30/36B EL296UH045XE36B 8268056 14ACX-036-230A TXV 33,400 15.00 12.50 C35-30/36B EL296UH045XV36B 8268057 14ACX-036-230A TXV 33,400 15.00 12.50 C35-30/36B EL296UH070XV36B 8268058 14ACX-036-230A TXV 33,600 15.50 12.50 C35-30/36B SL280UH090V36B 8268066 14ACX-036-230A TXV 33,600 15.50 12.50 C35-30/36B SL280UH090V48B 8268067 14ACX-036-230A TXV 33,600 15.50 12.50 C35-30/36B SL280UH090XV48B 8268060 14ACX-036-230A TXV 33,400 15.00 12.50 C35-30/36B SLP98UH070XV36B 8268059 14ACX-036-230A TXV 33,600 15.10 12.50 C35-30/36C EL180UH090E60C 8268075 14ACX-036-230A TXV 33,400 15.50 12.50 C35-30/36C EL180UH110E60C 8268076 14ACX-036-230A TXV 33,400 15.50 12.50 C35-30/36C EL180UH110XE60C 8268077 14ACX-036-230A TXV 33,200 15.10 12.50 C35-30/36C EL195UH090XE48C 8268078 14ACX-036-230A TXV 33,600 15.10 12.50 C35-30/36C EL195UH110XE60C 8268080 14ACX-036-230A TXV 33,200 15.10 12.50 C35-30/36C EL296UH090XE48C 8268079 14ACX-036-230A TXV 33,600 15.50 12.50 C35-30/36C EL296UH090XV36C 8268070 14ACX-036-230A TXV 33,400 15.50 12.50 C35-30/36C EL296UH090XV48C 8268072 14ACX-036-230A TXV 33,600 15.10 12.50 C35-30/36C EL296UH110XE60C 8268069 14ACX-036-230A TXV 33,600 15.50 12.50 C35-30/36C EL296UH110XV48C 8268074 14ACX-036-230A TXV 33,600 15.50 12.50 C35-30/36C SLP98UH090XV36C 8268071 14ACX-036-230A TXV 33,400 15.50 12.50 C35-30/36C SLP98UH090XV48C 8268073 14ACX-036-230A TXV 33,800 15.50 12.50 C35-30/36C SLP98UH110XV60C 8268068 14ACX-036-230A TXV 34,200 15.10 12.50 C35-30A EL180UH045E36A 8268036 14ACX-036-230A TXV 34,200 15.10 12.50 C35-30A EL180UH045XE36A 8268037 14ACX-036-230A TXV 34,400 15.10 12.50 C35-30A SL280UH070V36A 8268034 14ACX-036-230A TXV 34,400 15.10 12.50 C35-30A SL280UH070XV36A 8268035 14ACX-036-230A TXV 34,400 15.00 12.50 C35-30B EL180UH070E36B 8268047 14ACX-036-230A TXV 34,400 15.00 12.50 C35-30B EL180UH070XE36B 8268048 14ACX-036-230A TXV 34,400 15.50 12.50 C35-30B EL180UH090E48B 8268049 14ACX-036-230A TXV 34,400 15.50 12.50 C35-30B EL180UH090XE48B 8268050 14ACX-036-230A TXV 34,000 14.50 12.20 C35-30B EL195UH045XE36B 8268051 14ACX-036-230A TXV 34,000 15.10 12.50 C35-30B EL195UH070XE36B 8268041 14ACX-036-230A TXV 34,000 14.50 12.20 C35-30B EL296UH045XE36B 8268040 14ACX-036-230A TXV 34,200 15.10 12.50 C35-30B EL296UH045XV36B 8268043 14ACX-036-230A TXV 34,000 15.10 12.50 C35-30B EL296UH070XE36B 8268042 14ACX-036-230A TXV 34,200 15.10 12.50 C35-30B EL296UH070XV36B 8268044 14ACX-036-230A TXV 34,400 15.50 12.50 C35-30B SL280UH090V36B 8268038 14ACX-036-230A TXV 34,400 15.50 12.50 C35-30B SL280UH090V48B 8268039 14ACX-036-230A TXV 34,400 15.50 12.50 C35-30B SL280UH090XV48B 8268046 14ACX-036-230A TXV 34,200 15.10 12.50 C35-30B SLP98UH070XV36B 8268045 14ACX-036-230A TXV 34,400 15.10 12.50 C35-36A EL180UH045E36A 8268084 14ACX-036-230A TXV 34,400 15.10 12.50 C35-36A EL180UH045XE36A 8268085 14ACX-036-230A TXV 34,600 15.50 12.50 C35-36A SL280UH070V36A 8268082 14ACX-036-230A TXV 34,600 15.50 12.50 C35-36A SL280UH070XV36A 8268083 14ACX-036-230A TXV 34,200 14.25 12.20 C35-36A 8268081 14ACX-036-230A TXV 34,600 16.00 13.00 C35-36B EL180UH070E36B 8268094 14ACX-036-230A TXV 34,600 16.00 13.00 C35-36B EL180UH070XE36B 8268095 14ACX-036-230A TXV 34,600 16.00 13.00 C35-36B EL180UH090E48B 8268096 14ACX-036-230A TXV 34,600 16.00 13.00 C35-36B EL180UH090XE48B 8268097 14ACX-036-230A TXV 34,400 15.00 12.50 C35-36B EL195UH045XE36B 8268098 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 160 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 34,400 15.00 12.50 C35-36B EL195UH070XE36B 8268088 14ACX-036-230A TXV 34,400 15.00 12.50 C35-36B EL296UH045XE36B 8268087 14ACX-036-230A TXV 34,600 15.50 12.50 C35-36B EL296UH045XV36B 8268090 14ACX-036-230A TXV 34,400 15.00 12.50 C35-36B EL296UH070XE36B 8268089 14ACX-036-230A TXV 34,600 15.50 12.50 C35-36B EL296UH070XV36B 8268091 14ACX-036-230A TXV 34,800 16.00 13.00 C35-36B SL280UH090V36B 8268099 14ACX-036-230A TXV 34,800 16.00 13.00 C35-36B SL280UH090V48B 8268100 14ACX-036-230A TXV 34,800 16.00 13.00 C35-36B SL280UH090XV48B 8268093 14ACX-036-230A TXV 34,600 15.50 12.50 C35-36B SLP98UH070XV36B 8268092 14ACX-036-230A TXV 34,200 14.25 12.20 C35-36B 8268086 14ACX-036-230A TXV 34,800 16.00 13.00 C35-48B EL180UH070E36B 8268113 14ACX-036-230A TXV 34,800 16.00 13.00 C35-48B EL180UH070XE36B 8268114 14ACX-036-230A TXV 34,800 16.00 13.00 C35-48B EL180UH090E48B 8268115 14ACX-036-230A TXV 34,800 16.00 13.00 C35-48B EL180UH090XE48B 8268104 14ACX-036-230A TXV 34,400 15.00 12.50 C35-48B EL195UH045XE36B 8268105 14ACX-036-230A TXV 34,600 15.10 12.50 C35-48B EL195UH070XE36B 8268107 14ACX-036-230A TXV 34,400 15.00 12.50 C35-48B EL296UH045XE36B 8268106 14ACX-036-230A TXV 34,800 15.50 12.50 C35-48B EL296UH045XV36B 8268109 14ACX-036-230A TXV 34,600 15.10 12.50 C35-48B EL296UH070XE36B 8268108 14ACX-036-230A TXV 34,800 15.50 12.50 C35-48B EL296UH070XV36B 8268102 14ACX-036-230A TXV 34,800 16.00 13.00 C35-48B SL280UH090V36B 8268110 14ACX-036-230A TXV 35,000 16.00 13.00 C35-48B SL280UH090V48B 8268111 14ACX-036-230A TXV 35,000 16.00 13.00 C35-48B SL280UH090XV48B 8268112 14ACX-036-230A TXV 34,800 15.50 12.50 C35-48B SLP98UH070XV36B 8268103 14ACX-036-230A TXV 34,400 14.50 12.20 C35-48B 8268101 14ACX-036-230A TXV 34,800 16.00 13.00 C35-48C EL180UH090E60C 8268125 14ACX-036-230A TXV 34,800 16.00 13.00 C35-48C EL180UH110E60C 8268126 14ACX-036-230A TXV 34,800 16.00 13.00 C35-48C EL180UH110XE60C 8268127 14ACX-036-230A TXV 34,600 15.50 12.50 C35-48C EL195UH090XE48C 8268128 14ACX-036-230A TXV 34,800 16.00 13.00 C35-48C EL195UH110XE60C 8268130 14ACX-036-230A TXV 34,600 15.50 12.50 C35-48C EL296UH090XE48C 8268129 14ACX-036-230A TXV 34,800 16.00 13.00 C35-48C EL296UH090XV36C 8268120 14ACX-036-230A TXV 34,800 16.00 13.00 C35-48C EL296UH090XV48C 8268122 14ACX-036-230A TXV 34,600 16.00 13.00 C35-48C EL296UH110XE60C 8268119 14ACX-036-230A TXV 35,000 16.00 13.00 C35-48C EL296UH110XV48C 8268124 14ACX-036-230A TXV 35,200 16.00 13.00 C35-48C EL296UH110XV60C 8268117 14ACX-036-230A TXV 35,400 16.00 13.00 C35-48C SL280UH090V60C 8268131 14ACX-036-230A TXV 35,400 16.00 13.00 C35-48C SL280UH090XV60C 8268132 14ACX-036-230A TXV 35,200 16.00 13.00 C35-48C SL280UH110V60C 8268133 14ACX-036-230A TXV 35,200 16.00 13.00 C35-48C SL280UH110XV60C 8268134 14ACX-036-230A TXV 34,800 16.00 13.00 C35-48C SLP98UH090XV36C 8268121 14ACX-036-230A TXV 34,800 16.00 13.00 C35-48C SLP98UH090XV48C 8268123 14ACX-036-230A TXV 35,200 16.00 13.00 C35-48C SLP98UH110XV60C 8268118 14ACX-036-230A TXV 34,400 14.50 12.20 C35-48C 8268116 14ACX-036-230A TXV 35,200 16.00 13.00 C35-49C EL180UH090E60C 8268150 14ACX-036-230A TXV 35,000 16.00 13.00 C35-49C EL180UH110E60C 8268151 14ACX-036-230A TXV 35,000 16.00 13.00 C35-49C EL180UH110XE60C 8268152 14ACX-036-230A TXV 34,800 16.00 13.00 C35-49C EL195UH090XE48C 8268141 14ACX-036-230A TXV 35,200 16.00 13.00 C35-49C EL195UH110XE60C 8268143 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 161 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 34,800 16.00 13.00 C35-49C EL296UH090XE48C 8268142 14ACX-036-230A TXV 35,200 16.00 13.00 C35-49C EL296UH090XV36C 8268145 14ACX-036-230A TXV 35,000 16.00 13.00 C35-49C EL296UH090XV48C 8268136 14ACX-036-230A TXV 35,200 16.00 13.00 C35-49C EL296UH110XE60C 8268144 14ACX-036-230A TXV 35,200 16.00 13.00 C35-49C EL296UH110XV48C 8268138 14ACX-036-230A TXV 35,600 16.00 13.00 C35-49C EL296UH110XV60C 8268139 14ACX-036-230A TXV 35,600 16.00 13.00 C35-49C SL280UH090V60C 8268153 14ACX-036-230A TXV 35,600 16.00 13.00 C35-49C SL280UH090XV60C 8268147 14ACX-036-230A TXV 35,400 16.00 13.00 C35-49C SL280UH110V60C 8268148 14ACX-036-230A TXV 35,400 16.00 13.00 C35-49C SL280UH110XV60C 8268149 14ACX-036-230A TXV 35,200 16.00 13.00 C35-49C SLP98UH090XV36C 8268146 14ACX-036-230A TXV 35,000 16.00 13.00 C35-49C SLP98UH090XV48C 8268137 14ACX-036-230A TXV 35,600 16.00 13.00 C35-49C SLP98UH110XV60C 8268140 14ACX-036-230A TXV 34,600 14.50 12.20 C35-49C 8268135 14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C EL180UH090E60C 8268171 14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C EL180UH110E60C 8268172 14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C EL180UH110XE60C 8268161 14ACX-036-230A TXV 34,400 15.50 12.50 C35-50/60C EL195UH090XE48C 8268162 14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C EL195UH110XE60C 8268164 14ACX-036-230A TXV 34,400 15.50 12.50 C35-50/60C EL296UH090XE48C 8268163 14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C EL296UH090XV36C 8268166 14ACX-036-230A TXV 34,600 16.00 13.00 C35-50/60C EL296UH090XV48C 8268156 14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C EL296UH110XE60C 8268165 14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C EL296UH110XV48C 8268158 14ACX-036-230A TXV 35,200 16.00 13.00 C35-50/60C EL296UH110XV60C 8268159 14ACX-036-230A TXV 35,200 16.00 13.00 C35-50/60C SL280UH090V60C 8268167 14ACX-036-230A TXV 35,200 16.00 13.00 C35-50/60C SL280UH090XV60C 8268168 14ACX-036-230A TXV 35,000 16.00 13.00 C35-50/60C SL280UH110V60C 8268169 14ACX-036-230A TXV 35,000 16.00 13.00 C35-50/60C SL280UH110XV60C 8268170 14ACX-036-230A TXV 34,800 16.00 13.00 C35-50/60C SLP98UH090XV36C 8268155 14ACX-036-230A TXV 34,600 16.00 13.00 C35-50/60C SLP98UH090XV48C 8268157 14ACX-036-230A TXV 35,200 16.00 13.00 C35-50/60C SLP98UH110XV60C 8268160 14ACX-036-230A TXV 34,200 14.50 12.20 C35-50/60C 8268154 14ACX-036-230A TXV 34,600 16.00 13.00 CBA27UHE-036 10259478 14ACX-036-230A TXV 35,600 16.00 13.00 CBA27UHE-042 10259378 14ACX-036-230A TXV 34,200 14.50 12.20 CBX25UH-036 7510388 14ACX-036-230A TXV 34,600 15.00 12.50 CBX25UH-042 7510389 14ACX-036-230A TXV 34,400 15.00 12.50 CBX25UHV-036 7510390 14ACX-036-230A TXV 35,200 16.00 13.00 CBX25UHV-042 7510391 14ACX-036-230A TXV 34,200 16.00 13.00 CBX27UH-036 7510392 14ACX-036-230A TXV 35,200 16.00 13.00 CBX27UH-042 7510393 14ACX-036-230A TXV 33,400 14.50 12.20 CBX32M-030 7510394 14ACX-036-230A TXV 33,800 14.50 12.20 CBX32M-036 7510395 14ACX-036-230A TXV 33,800 14.50 12.20 CBX32M-042 7510396 14ACX-036-230A TXV 34,800 15.10 12.50 CBX32M-048 7510397 14ACX-036-230A TXV 34,000 15.10 12.50 CBX32MV-036 7510398 14ACX-036-230A TXV 35,200 16.00 13.00 CBX32MV-048 7510399 14ACX-036-230A TXV 34,200 15.10 12.50 CBX40UHV-036 7510400 14ACX-036-230A TXV 35,000 15.50 12.50 CBX40UHV-042 7510401 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 162 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 35,000 16.00 13.00 CBX40UHV-048 7510402 14ACX-036-230A TXV 33,600 15.00 12.50 CH23-41 EL180UH045E36A 7510406 14ACX-036-230A TXV 33,600 15.00 12.50 CH23-41 EL180UH045XE36A 7510407 14ACX-036-230A TXV 33,800 15.50 12.50 CH23-41 EL180UH070E36B 7510408 14ACX-036-230A TXV 33,800 15.50 12.50 CH23-41 EL180UH070XE36B 7510409 14ACX-036-230A TXV 33,800 15.50 12.50 CH23-41 EL180UH090E48B 7510410 14ACX-036-230A TXV 33,800 15.50 12.50 CH23-41 EL180UH090XE48B 7510411 14ACX-036-230A TXV 33,600 15.10 12.50 CH23-41 EL195UH045XE36B 7510412 14ACX-036-230A TXV 33,800 15.10 12.50 CH23-41 EL195UH070XE36B 7510414 14ACX-036-230A TXV 33,600 15.10 12.50 CH23-41 EL296UH045XE36B 7510413 14ACX-036-230A TXV 33,800 15.10 12.50 CH23-41 EL296UH045XV36B 7510416 14ACX-036-230A TXV 33,800 15.10 12.50 CH23-41 EL296UH070XE36B 7510415 14ACX-036-230A TXV 33,800 15.10 12.50 CH23-41 EL296UH070XV36B 7510417 14ACX-036-230A TXV 34,000 16.00 13.00 CH23-41 SL280UH090V48B 7510404 14ACX-036-230A TXV 34,000 16.00 13.00 CH23-41 SL280UH090XV48B 7510405 14ACX-036-230A TXV 33,800 15.10 12.50 CH23-41 SLP98UH070XV36B 7510418 14ACX-036-230A TXV 33,600 15.00 12.50 CH23-51 EL180UH045E36A 7510423 14ACX-036-230A TXV 33,600 15.00 12.50 CH23-51 EL180UH045XE36A 7510424 14ACX-036-230A TXV 33,800 15.50 12.50 CH23-51 EL180UH070E36B 7510425 14ACX-036-230A TXV 33,800 15.50 12.50 CH23-51 EL180UH070XE36B 7510426 14ACX-036-230A TXV 33,800 15.50 12.50 CH23-51 EL180UH090E48B 7510427 14ACX-036-230A TXV 34,000 15.50 12.50 CH23-51 EL180UH090E60C 7510438 14ACX-036-230A TXV 33,800 15.50 12.50 CH23-51 EL180UH090XE48B 7510428 14ACX-036-230A TXV 34,000 15.50 12.50 CH23-51 EL180UH110E60C 7510439 14ACX-036-230A TXV 34,000 15.50 12.50 CH23-51 EL180UH110XE60C 7510440 14ACX-036-230A TXV 33,600 15.10 12.50 CH23-51 EL195UH045XE36B 7510429 14ACX-036-230A TXV 33,800 15.10 12.50 CH23-51 EL195UH070XE36B 7510431 14ACX-036-230A TXV 33,600 15.10 12.50 CH23-51 EL195UH090XE48C 7510441 14ACX-036-230A TXV 34,000 15.50 12.50 CH23-51 EL195UH110XE60C 7510443 14ACX-036-230A TXV 33,600 15.10 12.50 CH23-51 EL296UH045XE36B 7510430 14ACX-036-230A TXV 34,000 15.10 12.50 CH23-51 EL296UH045XV36B 7510433 14ACX-036-230A TXV 33,800 15.10 12.50 CH23-51 EL296UH070XE36B 7510432 14ACX-036-230A TXV 34,000 15.10 12.50 CH23-51 EL296UH070XV36B 7510434 14ACX-036-230A TXV 33,600 15.10 12.50 CH23-51 EL296UH090XE48C 7510442 14ACX-036-230A TXV 34,000 15.50 12.50 CH23-51 EL296UH090XV36C 7510445 14ACX-036-230A TXV 33,800 15.50 12.50 CH23-51 EL296UH090XV48C 7510447 14ACX-036-230A TXV 34,000 15.50 12.50 CH23-51 EL296UH110XE60C 7510444 14ACX-036-230A TXV 34,000 15.50 12.50 CH23-51 EL296UH110XV48C 7510449 14ACX-036-230A TXV 34,200 15.50 12.50 CH23-51 EL296UH110XV60C 7510450 14ACX-036-230A TXV 34,000 16.00 13.00 CH23-51 SL280UH090V36B 7510420 14ACX-036-230A TXV 34,200 16.00 13.00 CH23-51 SL280UH090V48B 7510421 14ACX-036-230A TXV 34,400 15.50 12.50 CH23-51 SL280UH090V60C 7513171 14ACX-036-230A TXV 34,200 16.00 13.00 CH23-51 SL280UH090XV48B 7510422 14ACX-036-230A TXV 34,400 15.50 12.50 CH23-51 SL280UH090XV60C 7513172 14ACX-036-230A TXV 34,200 15.50 12.50 CH23-51 SL280UH110V60C 7510436 14ACX-036-230A TXV 34,200 15.50 12.50 CH23-51 SL280UH110XV60C 7510437 14ACX-036-230A TXV 34,000 15.10 12.50 CH23-51 SLP98UH070XV36B 7510435 14ACX-036-230A TXV 34,000 15.50 12.50 CH23-51 SLP98UH090XV36C 7510446 14ACX-036-230A TXV 33,800 15.50 12.50 CH23-51 SLP98UH090XV48C 7510448 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 163 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 34,200 15.50 12.50 CH23-51 SLP98UH110XV60C 7510451 14ACX-036-230A TXV 34,000 15.00 12.50 CH33-31A EL180UH045E36A 7510454 14ACX-036-230A TXV 34,000 15.00 12.50 CH33-31A EL180UH045XE36A 7510455 14ACX-036-230A TXV 34,200 15.10 12.50 CH33-31A SL280UH070V36A 7510452 14ACX-036-230A TXV 34,200 15.10 12.50 CH33-31A SL280UH070XV36A 7510453 14ACX-036-230A TXV 34,600 15.10 12.50 CH33-31B EL180UH070E36B 7510461 14ACX-036-230A TXV 34,600 15.10 12.50 CH33-31B EL180UH070XE36B 7510462 14ACX-036-230A TXV 34,600 15.50 12.50 CH33-31B EL180UH090E48B 7510463 14ACX-036-230A TXV 34,600 15.50 12.50 CH33-31B EL180UH090XE48B 7510464 14ACX-036-230A TXV 34,200 14.50 12.20 CH33-31B EL195UH045XE36B 7510465 14ACX-036-230A TXV 34,400 15.00 12.50 CH33-31B EL195UH070XE36B 7510467 14ACX-036-230A TXV 34,200 14.50 12.20 CH33-31B EL296UH045XE36B 7510466 14ACX-036-230A TXV 34,600 15.10 12.50 CH33-31B EL296UH045XV36B 7510469 14ACX-036-230A TXV 34,400 15.00 12.50 CH33-31B EL296UH070XE36B 7510468 14ACX-036-230A TXV 34,600 15.10 12.50 CH33-31B EL296UH070XV36B 7510470 14ACX-036-230A TXV 34,800 16.00 13.00 CH33-31B SL280UH090V36B 7510458 14ACX-036-230A TXV 34,800 15.50 12.50 CH33-31B SL280UH090V48B 7510459 14ACX-036-230A TXV 34,800 15.50 12.50 CH33-31B SL280UH090XV48B 7510460 14ACX-036-230A TXV 34,600 15.10 12.50 CH33-31B SLP98UH070XV36B 7510471 14ACX-036-230A TXV 34,200 14.50 12.20 CH33-31B 7510457 14ACX-036-230A TXV 33,000 14.50 12.20 CH33-36A EL180UH045E36A 7510474 14ACX-036-230A TXV 33,000 14.50 12.20 CH33-36A EL180UH045XE36A 7510475 14ACX-036-230A TXV 33,200 14.50 12.20 CH33-36A SL280UH070V36A 7510472 14ACX-036-230A TXV 33,200 14.50 12.20 CH33-36A SL280UH070XV36A 7510473 14ACX-036-230A TXV 33,400 15.50 12.50 CH33-36B EL180UH070E36B 7510480 14ACX-036-230A TXV 33,400 15.50 12.50 CH33-36B EL180UH070XE36B 7510481 14ACX-036-230A TXV 33,400 15.10 12.50 CH33-36B EL180UH090E48B 7510482 14ACX-036-230A TXV 33,400 15.10 12.50 CH33-36B EL180UH090XE48B 7510483 14ACX-036-230A TXV 33,000 15.00 12.50 CH33-36B EL195UH045XE36B 7510484 14ACX-036-230A TXV 33,200 15.00 12.50 CH33-36B EL195UH070XE36B 7510486 14ACX-036-230A TXV 33,000 15.00 12.50 CH33-36B EL296UH045XE36B 7510485 14ACX-036-230A TXV 33,400 14.50 12.20 CH33-36B EL296UH045XV36B 7513173 14ACX-036-230A TXV 33,200 15.00 12.50 CH33-36B EL296UH070XE36B 7510487 14ACX-036-230A TXV 33,400 15.00 12.50 CH33-36B EL296UH070XV36B 7510488 14ACX-036-230A TXV 33,400 15.50 12.50 CH33-36B SL280UH090V36B 7510477 14ACX-036-230A TXV 33,600 15.50 12.50 CH33-36B SL280UH090V48B 7510478 14ACX-036-230A TXV 33,600 15.50 12.50 CH33-36B SL280UH090XV48B 7510479 14ACX-036-230A TXV 33,400 15.00 12.50 CH33-36B SLP98UH070XV36B 7510489 14ACX-036-230A TXV 33,800 15.50 12.50 CH33-36C EL180UH090E60C 7510493 14ACX-036-230A TXV 33,800 15.50 12.50 CH33-36C EL180UH110E60C 7510494 14ACX-036-230A TXV 33,800 15.50 12.50 CH33-36C EL180UH110XE60C 7510495 14ACX-036-230A TXV 33,600 15.10 12.50 CH33-36C EL195UH090XE48C 7510496 14ACX-036-230A TXV 34,000 15.50 12.50 CH33-36C EL195UH110XE60C 7510498 14ACX-036-230A TXV 33,600 15.10 12.50 CH33-36C EL296UH090XE48C 7510497 14ACX-036-230A TXV 34,000 15.50 12.50 CH33-36C EL296UH090XV36C 7510500 14ACX-036-230A TXV 33,800 15.50 12.50 CH33-36C EL296UH090XV48C 7510502 14ACX-036-230A TXV 34,000 15.50 12.50 CH33-36C EL296UH110XE60C 7510499 14ACX-036-230A TXV 34,000 15.50 12.50 CH33-36C EL296UH110XV48C 7510504 14ACX-036-230A TXV 34,200 15.50 12.50 CH33-36C EL296UH110XV60C 7510505 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 164 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 34,400 15.50 12.50 CH33-36C SL280UH090V60C 7513175 14ACX-036-230A TXV 34,400 15.50 12.50 CH33-36C SL280UH090XV60C 7513177 14ACX-036-230A TXV 34,200 15.50 12.50 CH33-36C SL280UH110V60C 7510491 14ACX-036-230A TXV 34,200 15.50 12.50 CH33-36C SL280UH110XV60C 7510492 14ACX-036-230A TXV 34,000 15.50 12.50 CH33-36C SLP98UH090XV36C 7510501 14ACX-036-230A TXV 33,800 15.50 12.50 CH33-36C SLP98UH090XV48C 7510503 14ACX-036-230A TXV 34,200 15.50 12.50 CH33-36C SLP98UH110XV60C 7510506 14ACX-036-230A TXV 34,200 15.00 12.50 CH33-42B EL180UH070E36B 7513181 14ACX-036-230A TXV 34,200 15.00 12.50 CH33-42B EL180UH070XE36B 7513182 14ACX-036-230A TXV 34,200 15.50 12.50 CH33-42B EL180UH090E48B 7513183 14ACX-036-230A TXV 34,200 15.50 12.50 CH33-42B EL180UH090XE48B 7513184 14ACX-036-230A TXV 34,000 14.50 12.20 CH33-42B EL195UH045XE36B 7513185 14ACX-036-230A TXV 34,000 15.10 12.50 CH33-42B EL195UH070XE36B 7513187 14ACX-036-230A TXV 34,000 14.50 12.20 CH33-42B EL296UH045XE36B 7513186 14ACX-036-230A TXV 34,200 15.00 12.50 CH33-42B EL296UH045XV36B 7513189 14ACX-036-230A TXV 34,000 15.10 12.50 CH33-42B EL296UH070XE36B 7513188 14ACX-036-230A TXV 34,200 15.10 12.50 CH33-42B EL296UH070XV36B 7513190 14ACX-036-230A TXV 34,400 15.50 12.50 CH33-42B SL280UH090V36B 7513178 14ACX-036-230A TXV 34,400 15.50 12.50 CH33-42B SL280UH090V48B 7513179 14ACX-036-230A TXV 34,400 15.50 12.50 CH33-42B SL280UH090XV48B 7513180 14ACX-036-230A TXV 34,200 15.10 12.50 CH33-42B SLP98UH070XV36B 7513191 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-43B EL180UH070E36B 7510512 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-43B EL180UH070XE36B 7510513 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-43B EL180UH090E48B 7510514 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-43B EL180UH090XE48B 7510515 14ACX-036-230A TXV 35,000 15.10 12.50 CH33-43B EL195UH045XE36B 7510516 14ACX-036-230A TXV 35,000 15.10 12.50 CH33-43B EL195UH070XE36B 7510518 14ACX-036-230A TXV 35,000 15.10 12.50 CH33-43B EL296UH045XE36B 7510517 14ACX-036-230A TXV 35,400 15.50 12.50 CH33-43B EL296UH045XV36B 7510520 14ACX-036-230A TXV 35,000 15.10 12.50 CH33-43B EL296UH070XE36B 7510519 14ACX-036-230A TXV 35,400 15.50 12.50 CH33-43B EL296UH070XV36B 7510521 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-43B SL280UH090V36B 7510509 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-43B SL280UH090V48B 7510510 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-43B SL280UH090XV48B 7510511 14ACX-036-230A TXV 35,400 15.50 12.50 CH33-43B SLP98UH070XV36B 7510522 14ACX-036-230A TXV 35,000 14.50 12.20 CH33-43B 7510508 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-43C EL180UH090E60C 7510527 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-43C EL180UH110E60C 7510528 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-43C EL180UH110XE60C 7510529 14ACX-036-230A TXV 34,800 16.00 13.00 CH33-43C EL195UH090XE48C 7510530 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-43C EL195UH110XE60C 7510532 14ACX-036-230A TXV 34,800 16.00 13.00 CH33-43C EL296UH090XE48C 7510531 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-43C EL296UH090XV36C 7510534 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-43C EL296UH090XV48C 7510536 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-43C EL296UH110XE60C 7510533 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-43C EL296UH110XV48C 7510538 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-43C EL296UH110XV60C 7510539 14ACX-036-230A TXV 35,600 16.00 13.00 CH33-43C SL280UH090V60C 7510523 14ACX-036-230A TXV 35,600 16.00 13.00 CH33-43C SL280UH090XV60C 7510524 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 165 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-43C SL280UH110V60C 7510525 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-43C SL280UH110XV60C 7510526 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-43C SLP98UH090XV36C 7510535 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-43C SLP98UH090XV48C 7510537 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-43C SLP98UH110XV60C 7510540 14ACX-036-230A TXV 34,600 15.10 12.50 CH33-44/48B EL180UH070E36B 7510546 14ACX-036-230A TXV 34,600 15.10 12.50 CH33-44/48B EL180UH070XE36B 7510547 14ACX-036-230A TXV 34,600 15.50 12.50 CH33-44/48B EL180UH090E48B 7510548 14ACX-036-230A TXV 34,600 15.50 12.50 CH33-44/48B EL180UH090XE48B 7510549 14ACX-036-230A TXV 34,400 14.50 12.20 CH33-44/48B EL195UH045XE36B 7510550 14ACX-036-230A TXV 34,400 15.00 12.50 CH33-44/48B EL195UH070XE36B 7510552 14ACX-036-230A TXV 34,400 14.50 12.20 CH33-44/48B EL296UH045XE36B 7510551 14ACX-036-230A TXV 34,600 15.10 12.50 CH33-44/48B EL296UH045XV36B 7510554 14ACX-036-230A TXV 34,400 15.00 12.50 CH33-44/48B EL296UH070XE36B 7510553 14ACX-036-230A TXV 34,600 15.10 12.50 CH33-44/48B EL296UH070XV36B 7510555 14ACX-036-230A TXV 34,800 16.00 13.00 CH33-44/48B SL280UH090V36B 7510543 14ACX-036-230A TXV 34,800 15.50 12.50 CH33-44/48B SL280UH090V48B 7510544 14ACX-036-230A TXV 34,800 15.50 12.50 CH33-44/48B SL280UH090XV48B 7510545 14ACX-036-230A TXV 34,600 15.10 12.50 CH33-44/48B SLP98UH070XV36B 7510556 14ACX-036-230A TXV 34,200 14.50 12.20 CH33-44/48B 7510542 14ACX-036-230A TXV 34,800 16.00 13.00 CH33-48C EL180UH090E60C 7510562 14ACX-036-230A TXV 34,800 16.00 13.00 CH33-48C EL180UH110E60C 7510563 14ACX-036-230A TXV 34,800 16.00 13.00 CH33-48C EL180UH110XE60C 7510564 14ACX-036-230A TXV 34,600 15.50 12.50 CH33-48C EL195UH090XE48C 7510565 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-48C EL195UH110XE60C 7510567 14ACX-036-230A TXV 34,600 15.50 12.50 CH33-48C EL296UH090XE48C 7510566 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-48C EL296UH090XV36C 7510569 14ACX-036-230A TXV 34,800 16.00 13.00 CH33-48C EL296UH090XV48C 7510571 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-48C EL296UH110XE60C 7510568 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-48C EL296UH110XV48C 7510573 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-48C EL296UH110XV60C 7510574 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-48C SL280UH090V60C 7510558 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-48C SL280UH090XV60C 7510559 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-48C SL280UH110V60C 7510560 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-48C SL280UH110XV60C 7510561 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-48C SLP98UH090XV36C 7510570 14ACX-036-230A TXV 34,800 16.00 13.00 CH33-48C SLP98UH090XV48C 7510572 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-48C SLP98UH110XV60C 7510575 14ACX-036-230A TXV 34,400 14.50 12.20 CH33-48C 7510557 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-49 EL180UH090E60C 7513199 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-49 EL180UH110E60C 7513200 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-49 EL180UH110XE60C 7513201 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-49 EL195UH090XE48C 7513202 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-49 EL195UH110XE60C 7513204 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-49 EL296UH090XE48C 7513203 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-49 EL296UH090XV36C 7513206 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-49 EL296UH090XV48C 7513208 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-49 EL296UH110XE60C 7513205 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-49 EL296UH110XV48C 7513210 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 166 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 35,800 16.00 13.00 CH33-49 EL296UH110XV60C 7513211 14ACX-036-230A TXV 35,800 16.00 13.00 CH33-49 SL280UH090V60C 7513195 14ACX-036-230A TXV 35,800 16.00 13.00 CH33-49 SL280UH090XV60C 7513196 14ACX-036-230A TXV 35,600 16.00 13.00 CH33-49 SL280UH110V60C 7513197 14ACX-036-230A TXV 35,600 16.00 13.00 CH33-49 SL280UH110XV60C 7513198 14ACX-036-230A TXV 35,400 16.00 13.00 CH33-49 SLP98UH090XV36C 7513207 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-49 SLP98UH090XV48C 7513209 14ACX-036-230A TXV 35,800 16.00 13.00 CH33-49 SLP98UH110XV60C 7513212 14ACX-036-230A TXV 34,800 14.50 12.20 CH33-49 7513194 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-50/60C EL180UH090E60C 7510580 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-50/60C EL180UH110E60C 7510581 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-50/60C EL180UH110XE60C 7510582 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-50/60C EL195UH090XE48C 7510583 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-50/60C EL195UH110XE60C 7510585 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-50/60C EL296UH090XE48C 7510584 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-50/60C EL296UH090XV36C 7510587 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-50/60C EL296UH090XV48C 7510589 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-50/60C EL296UH110XE60C 7510586 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-50/60C EL296UH110XV48C 7510591 14ACX-036-230A TXV 35,600 16.00 13.00 CH33-50/60C EL296UH110XV60C 7510592 14ACX-036-230A TXV 35,600 16.00 13.00 CH33-50/60C SL280UH090V60C 7510576 14ACX-036-230A TXV 35,600 16.00 13.00 CH33-50/60C SL280UH090XV60C 7510577 14ACX-036-230A TXV 35,600 16.00 13.00 CH33-50/60C SL280UH110V60C 7510578 14ACX-036-230A TXV 35,600 16.00 13.00 CH33-50/60C SL280UH110XV60C 7510579 14ACX-036-230A TXV 35,200 16.00 13.00 CH33-50/60C SLP98UH090XV36C 7510588 14ACX-036-230A TXV 35,000 16.00 13.00 CH33-50/60C SLP98UH090XV48C 7510590 14ACX-036-230A TXV 35,600 16.00 13.00 CH33-50/60C SLP98UH110XV60C 7510593 14ACX-036-230A TXV 34,600 14.50 12.20 CH33-50/60C 7510595 14ACX-036-230A TXV 34,000 15.00 12.50 CH35-30A EL180UH045E36A 7510598 14ACX-036-230A TXV 34,000 15.00 12.50 CH35-30A EL180UH045XE36A 7510599 14ACX-036-230A TXV 34,200 15.10 12.50 CH35-30A SL280UH070V36A 7510596 14ACX-036-230A TXV 34,200 15.10 12.50 CH35-30A SL280UH070XV36A 7510597 14ACX-036-230A TXV 34,800 15.10 12.50 CH35-30B EL180UH070E36B 7510605 14ACX-036-230A TXV 34,800 15.10 12.50 CH35-30B EL180UH070XE36B 7510606 14ACX-036-230A TXV 34,800 16.00 13.00 CH35-30B EL180UH090E48B 7510607 14ACX-036-230A TXV 34,800 16.00 13.00 CH35-30B EL180UH090XE48B 7510608 14ACX-036-230A TXV 34,400 14.50 12.20 CH35-30B EL195UH045XE36B 7510609 14ACX-036-230A TXV 34,400 15.00 12.50 CH35-30B EL195UH070XE36B 7510611 14ACX-036-230A TXV 34,400 14.50 12.20 CH35-30B EL296UH045XE36B 7510610 14ACX-036-230A TXV 34,600 15.10 12.50 CH35-30B EL296UH045XV36B 7510613 14ACX-036-230A TXV 34,400 15.00 12.50 CH35-30B EL296UH070XE36B 7510612 14ACX-036-230A TXV 34,600 15.10 12.50 CH35-30B EL296UH070XV36B 7510614 14ACX-036-230A TXV 34,800 16.00 13.00 CH35-30B SL280UH090V36B 7510602 14ACX-036-230A TXV 34,800 15.50 12.50 CH35-30B SL280UH090V48B 7510603 14ACX-036-230A TXV 34,800 15.50 12.50 CH35-30B SL280UH090XV48B 7510604 14ACX-036-230A TXV 34,600 15.10 12.50 CH35-30B SLP98UH070XV36B 7510615 14ACX-036-230A TXV 34,200 14.50 12.20 CH35-30B 7510601 14ACX-036-230A TXV 33,000 14.50 12.20 CH35-36A EL180UH045E36A 7510618 14ACX-036-230A TXV 33,000 14.50 12.20 CH35-36A EL180UH045XE36A 7510619 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 167 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 33,200 14.50 12.20 CH35-36A SL280UH070V36A 7510616 14ACX-036-230A TXV 33,200 14.50 12.20 CH35-36A SL280UH070XV36A 7510617 14ACX-036-230A TXV 33,400 15.50 12.50 CH35-36B EL180UH070E36B 7510624 14ACX-036-230A TXV 33,400 15.50 12.50 CH35-36B EL180UH070XE36B 7510625 14ACX-036-230A TXV 33,400 15.10 12.50 CH35-36B EL180UH090E48B 7510626 14ACX-036-230A TXV 33,400 15.10 12.50 CH35-36B EL180UH090XE48B 7510627 14ACX-036-230A TXV 33,000 15.00 12.50 CH35-36B EL195UH045XE36B 7510628 14ACX-036-230A TXV 33,000 15.00 12.50 CH35-36B EL296UH045XE36B 7510629 14ACX-036-230A TXV 33,600 15.00 12.20 CH35-36B EL296UH045XV36B 7510632 14ACX-036-230A TXV 33,400 15.00 12.50 CH35-36B EL296UH070XV36B 7510633 14ACX-036-230A TXV 33,600 15.50 12.50 CH35-36B SL280UH090V36B 7510621 14ACX-036-230A TXV 33,800 15.50 12.50 CH35-36B SL280UH090V48B 7510622 14ACX-036-230A TXV 33,800 15.50 12.50 CH35-36B SL280UH090XV48B 7510623 14ACX-036-230A TXV 33,400 15.00 12.50 CH35-36B SLP98UH070XV36B 7510634 14ACX-036-230A TXV 34,000 15.50 12.50 CH35-36C EL180UH090E60C 7510638 14ACX-036-230A TXV 33,800 15.50 12.50 CH35-36C EL180UH110E60C 7510639 14ACX-036-230A TXV 33,800 15.50 12.50 CH35-36C EL180UH110XE60C 7510640 14ACX-036-230A TXV 33,600 15.10 12.50 CH35-36C EL195UH090XE48C 7510641 14ACX-036-230A TXV 34,000 15.50 12.50 CH35-36C EL195UH110XE60C 7510643 14ACX-036-230A TXV 33,600 15.10 12.50 CH35-36C EL296UH090XE48C 7510642 14ACX-036-230A TXV 34,000 15.50 12.50 CH35-36C EL296UH090XV36C 7510645 14ACX-036-230A TXV 33,800 15.50 12.50 CH35-36C EL296UH090XV48C 7510647 14ACX-036-230A TXV 34,000 15.50 12.50 CH35-36C EL296UH110XE60C 7510644 14ACX-036-230A TXV 34,000 15.50 12.50 CH35-36C EL296UH110XV48C 7510649 14ACX-036-230A TXV 34,400 15.50 12.50 CH35-36C EL296UH110XV60C 7513215 14ACX-036-230A TXV 34,400 15.50 12.50 CH35-36C SL280UH090V60C 7513213 14ACX-036-230A TXV 34,400 15.50 12.50 CH35-36C SL280UH090XV60C 7513214 14ACX-036-230A TXV 34,200 15.50 12.50 CH35-36C SL280UH110V60C 7510636 14ACX-036-230A TXV 34,200 15.50 12.50 CH35-36C SL280UH110XV60C 7510637 14ACX-036-230A TXV 34,000 15.50 12.50 CH35-36C SLP98UH090XV36C 7510646 14ACX-036-230A TXV 33,800 15.50 12.50 CH35-36C SLP98UH090XV48C 7510648 14ACX-036-230A TXV 34,400 15.50 12.50 CH35-36C SLP98UH110XV60C 7510650 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-42B EL180UH070E36B 7510655 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-42B EL180UH070XE36B 7510656 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-42B EL180UH090E48B 7510657 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-42B EL180UH090XE48B 7510658 14ACX-036-230A TXV 35,000 15.10 12.50 CH35-42B EL195UH045XE36B 7510659 14ACX-036-230A TXV 35,200 15.10 12.50 CH35-42B EL195UH070XE36B 7510661 14ACX-036-230A TXV 35,000 15.10 12.50 CH35-42B EL296UH045XE36B 7510660 14ACX-036-230A TXV 35,400 15.50 12.50 CH35-42B EL296UH045XV36B 7510663 14ACX-036-230A TXV 35,200 15.10 12.50 CH35-42B EL296UH070XE36B 7510662 14ACX-036-230A TXV 35,400 15.50 12.50 CH35-42B EL296UH070XV36B 7510664 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-42B SL280UH090V36B 7510652 14ACX-036-230A TXV 35,600 16.00 13.00 CH35-42B SL280UH090V48B 7510653 14ACX-036-230A TXV 35,600 16.00 13.00 CH35-42B SL280UH090XV48B 7510654 14ACX-036-230A TXV 35,400 15.50 12.50 CH35-42B SLP98UH070XV36B 7510665 14ACX-036-230A TXV 35,000 14.50 12.20 CH35-42B 7510651 14ACX-036-230A TXV 35,200 16.00 13.00 CH35-42C EL180UH090E60C 7510671 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-42C EL180UH110E60C 7510672 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 168 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-42C EL180UH110XE60C 7510673 14ACX-036-230A TXV 34,800 16.00 13.00 CH35-42C EL195UH090XE48C 7510674 14ACX-036-230A TXV 35,200 16.00 13.00 CH35-42C EL195UH110XE60C 7510676 14ACX-036-230A TXV 34,800 16.00 13.00 CH35-42C EL296UH090XE48C 7510675 14ACX-036-230A TXV 35,200 16.00 13.00 CH35-42C EL296UH090XV36C 7510678 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-42C EL296UH090XV48C 7510680 14ACX-036-230A TXV 35,200 16.00 13.00 CH35-42C EL296UH110XE60C 7510677 14ACX-036-230A TXV 35,200 16.00 13.00 CH35-42C EL296UH110XV48C 7510682 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-42C EL296UH110XV60C 7510683 14ACX-036-230A TXV 35,600 16.00 13.00 CH35-42C SL280UH090V60C 7510667 14ACX-036-230A TXV 35,600 16.00 13.00 CH35-42C SL280UH090XV60C 7510668 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-42C SL280UH110V60C 7510669 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-42C SL280UH110XV60C 7510670 14ACX-036-230A TXV 35,200 16.00 13.00 CH35-42C SLP98UH090XV36C 7510679 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-42C SLP98UH090XV48C 7510681 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-42C SLP98UH110XV60C 7510684 14ACX-036-230A TXV 34,600 14.50 12.20 CH35-42C 7510666 14ACX-036-230A TXV 34,800 15.10 12.50 CH35-48B EL180UH070E36B 7510689 14ACX-036-230A TXV 34,800 15.10 12.50 CH35-48B EL180UH070XE36B 7510690 14ACX-036-230A TXV 34,800 16.00 13.00 CH35-48B EL180UH090E48B 7510691 14ACX-036-230A TXV 34,800 16.00 13.00 CH35-48B EL180UH090XE48B 7510692 14ACX-036-230A TXV 34,400 15.00 12.20 CH35-48B EL195UH045XE36B 7510693 14ACX-036-230A TXV 34,600 15.00 12.50 CH35-48B EL195UH070XE36B 7510695 14ACX-036-230A TXV 34,400 15.00 12.20 CH35-48B EL296UH045XE36B 7510694 14ACX-036-230A TXV 35,000 15.10 12.50 CH35-48B EL296UH045XV36B 7510697 14ACX-036-230A TXV 34,600 15.00 12.50 CH35-48B EL296UH070XE36B 7510696 14ACX-036-230A TXV 34,800 15.50 12.50 CH35-48B EL296UH070XV36B 7510698 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-48B SL280UH090V36B 7510686 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-48B SL280UH090V48B 7510687 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-48B SL280UH090XV48B 7510688 14ACX-036-230A TXV 34,800 15.50 12.50 CH35-48B SLP98UH070XV36B 7510699 14ACX-036-230A TXV 34,400 14.50 12.20 CH35-48B 7510685 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-48C EL180UH090E60C 7510705 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-48C EL180UH110E60C 7510706 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-48C EL180UH110XE60C 7510707 14ACX-036-230A TXV 34,800 16.00 13.00 CH35-48C EL195UH090XE48C 7510708 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-48C EL195UH110XE60C 7510710 14ACX-036-230A TXV 34,800 16.00 13.00 CH35-48C EL296UH090XE48C 7510709 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-48C EL296UH090XV36C 7510712 14ACX-036-230A TXV 34,800 16.00 13.00 CH35-48C EL296UH090XV48C 7510714 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-48C EL296UH110XE60C 7510711 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-48C EL296UH110XV48C 7510716 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-48C EL296UH110XV60C 7510717 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-48C SL280UH090V60C 7510701 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-48C SL280UH090XV60C 7510702 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-48C SL280UH110V60C 7510703 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-48C SL280UH110XV60C 7510704 14ACX-036-230A TXV 35,000 16.00 13.00 CH35-48C SLP98UH090XV36C 7510713 14ACX-036-230A TXV 34,800 16.00 13.00 CH35-48C SLP98UH090XV48C 7510715 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 169 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-48C SLP98UH110XV60C 7510718 14ACX-036-230A TXV 34,400 14.50 12.20 CH35-48C 7510700 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-51C EL180UH090E60C 7510724 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-51C EL180UH110E60C 7510725 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-51C EL180UH110XE60C 7510726 14ACX-036-230A TXV 35,200 16.00 13.00 CH35-51C EL195UH090XE48C 7510727 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-51C EL195UH110XE60C 7510729 14ACX-036-230A TXV 35,200 16.00 13.00 CH35-51C EL296UH090XE48C 7510728 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-51C EL296UH090XV36C 7510731 14ACX-036-230A TXV 35,200 16.00 13.00 CH35-51C EL296UH090XV48C 7510733 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-51C EL296UH110XE60C 7510730 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-51C EL296UH110XV48C 7510735 14ACX-036-230A TXV 35,800 16.00 13.00 CH35-51C EL296UH110XV60C 7510736 14ACX-036-230A TXV 36,000 16.00 13.00 CH35-51C SL280UH090V60C 7510720 14ACX-036-230A TXV 36,000 16.00 13.00 CH35-51C SL280UH090XV60C 7510721 14ACX-036-230A TXV 35,800 16.00 13.00 CH35-51C SL280UH110V60C 7510722 14ACX-036-230A TXV 35,800 16.00 13.00 CH35-51C SL280UH110XV60C 7510723 14ACX-036-230A TXV 35,400 16.00 13.00 CH35-51C SLP98UH090XV36C 7510732 14ACX-036-230A TXV 35,200 16.00 13.00 CH35-51C SLP98UH090XV48C 7510734 14ACX-036-230A TXV 35,800 16.00 13.00 CH35-51C SLP98UH110XV60C 7510737 14ACX-036-230A TXV 34,800 14.50 12.20 CH35-51C 7510719 14ACX-036-230A TXV 33,600 14.50 12.20 CR33-30/36A EL180DF045E36A 7510739 14ACX-036-230A TXV 33,600 15.00 12.50 CR33-30/36A SL280DF070V36A 7510738 14ACX-036-230A TXV 33,600 15.50 12.50 CR33-30/36B EL180DF070E36B 7510742 14ACX-036-230A TXV 33,600 15.10 12.50 CR33-30/36B EL180DF090E48B 7510743 14ACX-036-230A TXV 33,600 15.10 12.50 CR33-30/36B EL195DF070XE48B 7510746 14ACX-036-230A TXV 33,600 15.00 12.20 CR33-30/36B EL296DF045XV36B 7510748 14ACX-036-230A TXV 33,600 15.10 12.50 CR33-30/36B EL296DF070XE48B 7510747 14ACX-036-230A TXV 33,600 14.50 12.20 CR33-30/36B EL296DF070XV48B 7510749 14ACX-036-230A TXV 33,800 15.10 12.50 CR33-30/36B SL280DF090V48B 7510741 14ACX-036-230A TXV 33,800 15.00 12.50 CR33-30/36B SLP98DF070XV36B 7510750 14ACX-036-230A TXV 33,800 15.50 12.50 CR33-30/36C EL180DF110E60C 7510753 14ACX-036-230A TXV 33,600 15.10 12.50 CR33-30/36C EL195DF090XE48C 7510754 14ACX-036-230A TXV 33,600 15.10 12.50 CR33-30/36C EL195DF110XE60C 7510756 14ACX-036-230A TXV 33,600 15.10 12.50 CR33-30/36C EL296DF090XE48C 7615392 14ACX-036-230A TXV 34,000 15.10 12.50 CR33-30/36C EL296DF090XV60C 7615394 14ACX-036-230A TXV 33,600 15.10 12.50 CR33-30/36C EL296DF110XE60C 7615393 14ACX-036-230A TXV 34,000 15.10 12.50 CR33-30/36C EL296DF110XV60C 7615395 14ACX-036-230A TXV 34,000 15.50 12.50 CR33-30/36C SL280DF110V60C 7510752 14ACX-036-230A TXV 33,800 15.10 12.50 CR33-30/36C SLP98DF090XV36C 7510758 14ACX-036-230A TXV 33,800 15.10 12.50 CR33-30/36C SLP98DF090XV48C 7510759 14ACX-036-230A TXV 34,000 15.10 12.50 CR33-30/36C SLP98DF090XV60C 7510761 14ACX-036-230A TXV 34,000 15.10 12.50 CR33-30/36C SLP98DF110XV60C 7510763 14ACX-036-230A TXV 34,200 15.00 12.50 CR33-48B EL180DF070E36B 7513219 14ACX-036-230A TXV 34,200 15.50 12.50 CR33-48B EL180DF090E48B 7513220 14ACX-036-230A TXV 34,000 15.10 12.50 CR33-48B EL195DF045XE36B 7513221 14ACX-036-230A TXV 34,000 15.50 12.50 CR33-48B EL195DF070XE48B 7513223 14ACX-036-230A TXV 34,000 15.50 12.50 CR33-48B EL296DF045XE36B 7513222 14ACX-036-230A TXV 34,200 15.10 12.50 CR33-48B EL296DF045XV36B 7622675 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 170 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 34,000 15.50 12.50 CR33-48B EL296DF070XE48B 7513224 14ACX-036-230A TXV 34,200 15.10 12.50 CR33-48B EL296DF070XV48B 7513226 14ACX-036-230A TXV 34,600 15.50 12.50 CR33-48B SL280DF090V48B 7513218 14ACX-036-230A TXV 34,000 15.50 12.50 CR33-48B SLP98DF070XV36B 7513227 14ACX-036-230A TXV 34,400 16.00 13.00 CR33-48C EL180DF110E60C 7513231 14ACX-036-230A TXV 34,200 15.50 12.50 CR33-48C EL195DF090XE48C 7513232 14ACX-036-230A TXV 34,200 15.50 12.50 CR33-48C EL195DF110XE60C 7513234 14ACX-036-230A TXV 34,200 15.50 12.50 CR33-48C EL296DF090XE48C 7513233 14ACX-036-230A TXV 34,600 15.50 12.50 CR33-48C EL296DF090XV60C 7513238 14ACX-036-230A TXV 34,200 15.50 12.50 CR33-48C EL296DF110XE60C 7513235 14ACX-036-230A TXV 34,600 15.50 12.50 CR33-48C EL296DF110XV60C 7513240 14ACX-036-230A TXV 34,600 16.00 13.00 CR33-48C SL280DF110V60C 7513230 14ACX-036-230A TXV 34,400 15.50 12.50 CR33-48C SLP98DF090XV36C 7513236 14ACX-036-230A TXV 34,400 16.00 13.00 CR33-48C SLP98DF090XV48C 7513237 14ACX-036-230A TXV 34,600 15.50 12.50 CR33-48C SLP98DF090XV60C 7513239 14ACX-036-230A TXV 34,600 15.50 12.50 CR33-48C SLP98DF110XV60C 7513241 14ACX-036-230A TXV 34,200 15.10 12.50 CX34-31A EL180UH045E36A 7510767 14ACX-036-230A TXV 34,200 15.10 12.50 CX34-31A EL180UH045XE36A 7510768 14ACX-036-230A TXV 34,400 15.10 12.50 CX34-31A SL280UH070V36A 7510765 14ACX-036-230A TXV 34,400 15.10 12.50 CX34-31A SL280UH070XV36A 7510766 14ACX-036-230A TXV 34,400 15.00 12.50 CX34-31B EL180UH070E36B 7510773 14ACX-036-230A TXV 34,400 15.00 12.50 CX34-31B EL180UH070XE36B 7510774 14ACX-036-230A TXV 34,400 15.50 12.50 CX34-31B EL180UH090E48B 7510775 14ACX-036-230A TXV 34,400 15.50 12.50 CX34-31B EL180UH090XE48B 7510776 14ACX-036-230A TXV 34,000 14.50 12.20 CX34-31B EL195UH045XE36B 7510777 14ACX-036-230A TXV 34,000 15.10 12.50 CX34-31B EL195UH070XE36B 7510779 14ACX-036-230A TXV 34,000 14.50 12.20 CX34-31B EL296UH045XE36B 7510778 14ACX-036-230A TXV 34,200 15.10 12.50 CX34-31B EL296UH045XV36B 7510781 14ACX-036-230A TXV 34,000 15.10 12.50 CX34-31B EL296UH070XE36B 7510780 14ACX-036-230A TXV 34,200 15.10 12.50 CX34-31B EL296UH070XV36B 7510782 14ACX-036-230A TXV 34,400 15.50 12.50 CX34-31B SL280UH090V36B 7510770 14ACX-036-230A TXV 34,400 15.50 12.50 CX34-31B SL280UH090V48B 7510771 14ACX-036-230A TXV 34,400 15.50 12.50 CX34-31B SL280UH090XV48B 7510772 14ACX-036-230A TXV 34,200 15.10 12.50 CX34-31B SLP98UH070XV36B 7510783 14ACX-036-230A TXV 33,200 14.50 12.20 CX34-36A EL180UH045E36A 7510787 14ACX-036-230A TXV 33,200 14.50 12.20 CX34-36A EL180UH045XE36A 7510788 14ACX-036-230A TXV 33,400 15.00 12.20 CX34-36A SL280UH070V36A 7510785 14ACX-036-230A TXV 33,400 15.00 12.20 CX34-36A SL280UH070XV36A 7510786 14ACX-036-230A TXV 33,400 15.50 12.50 CX34-36B EL180UH070E36B 7510793 14ACX-036-230A TXV 33,400 15.50 12.50 CX34-36B EL180UH070XE36B 7510794 14ACX-036-230A TXV 33,400 15.10 12.50 CX34-36B EL180UH090E48B 7510795 14ACX-036-230A TXV 33,400 15.10 12.50 CX34-36B EL180UH090XE48B 7510796 14ACX-036-230A TXV 33,000 15.00 12.50 CX34-36B EL195UH045XE36B 7510797 14ACX-036-230A TXV 33,000 15.00 12.50 CX34-36B EL296UH045XE36B 7510798 14ACX-036-230A TXV 33,400 15.00 12.50 CX34-36B EL296UH045XV36B 7510801 14ACX-036-230A TXV 33,400 15.00 12.50 CX34-36B EL296UH070XV36B 7510802 14ACX-036-230A TXV 33,600 15.50 12.50 CX34-36B SL280UH090V36B 7510790 14ACX-036-230A TXV 33,600 15.50 12.50 CX34-36B SL280UH090V48B 7510791 14ACX-036-230A TXV 33,600 15.50 12.50 CX34-36B SL280UH090XV48B 7510792 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 171 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 33,400 15.00 12.50 CX34-36B SLP98UH070XV36B 7510803 14ACX-036-230A TXV 33,600 15.10 12.50 CX34-36C EL180UH090E60C 7510805 14ACX-036-230A TXV 33,400 15.50 12.50 CX34-36C EL180UH110E60C 7510806 14ACX-036-230A TXV 33,400 15.50 12.50 CX34-36C EL180UH110XE60C 7510807 14ACX-036-230A TXV 33,200 15.10 12.50 CX34-36C EL195UH090XE48C 7510808 14ACX-036-230A TXV 33,600 15.10 12.50 CX34-36C EL195UH110XE60C 7510810 14ACX-036-230A TXV 33,200 15.10 12.50 CX34-36C EL296UH090XE48C 7510809 14ACX-036-230A TXV 33,600 15.50 12.50 CX34-36C EL296UH090XV36C 7510812 14ACX-036-230A TXV 33,400 15.50 12.50 CX34-36C EL296UH090XV48C 7510814 14ACX-036-230A TXV 33,600 15.10 12.50 CX34-36C EL296UH110XE60C 7510811 14ACX-036-230A TXV 33,600 15.50 12.50 CX34-36C EL296UH110XV48C 7510816 14ACX-036-230A TXV 33,600 15.50 12.50 CX34-36C SLP98UH090XV36C 7510813 14ACX-036-230A TXV 33,400 15.50 12.50 CX34-36C SLP98UH090XV48C 7510815 14ACX-036-230A TXV 33,800 15.50 12.50 CX34-36C SLP98UH110XV60C 7513242 14ACX-036-230A TXV 34,400 15.10 12.50 CX34-38A EL180UH045E36A 7510820 14ACX-036-230A TXV 34,400 15.10 12.50 CX34-38A EL180UH045XE36A 7510821 14ACX-036-230A TXV 34,600 15.50 12.50 CX34-38A SL280UH070V36A 7510818 14ACX-036-230A TXV 34,600 15.50 12.50 CX34-38A SL280UH070XV36A 7510819 14ACX-036-230A TXV 34,200 14.50 12.20 CX34-38A 7510817 14ACX-036-230A TXV 34,600 16.00 13.00 CX34-38B EL180UH070E36B 7510825 14ACX-036-230A TXV 34,600 16.00 13.00 CX34-38B EL180UH070XE36B 7510826 14ACX-036-230A TXV 34,600 15.50 12.50 CX34-38B EL180UH090E48B 7510827 14ACX-036-230A TXV 34,600 15.50 12.50 CX34-38B EL180UH090XE48B 7510828 14ACX-036-230A TXV 34,400 15.00 12.50 CX34-38B EL195UH045XE36B 7510829 14ACX-036-230A TXV 34,400 15.00 12.50 CX34-38B EL195UH070XE36B 7510831 14ACX-036-230A TXV 34,400 15.00 12.50 CX34-38B EL296UH045XE36B 7510830 14ACX-036-230A TXV 34,600 15.50 12.50 CX34-38B EL296UH045XV36B 7510833 14ACX-036-230A TXV 34,400 15.00 12.50 CX34-38B EL296UH070XE36B 7510832 14ACX-036-230A TXV 34,600 15.50 12.50 CX34-38B EL296UH070XV36B 7510834 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-38B SL280UH090V36B 7510822 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-38B SL280UH090V48B 7510823 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-38B SL280UH090XV48B 7510824 14ACX-036-230A TXV 34,600 15.50 12.50 CX34-38B SLP98UH070XV36B 7510835 14ACX-036-230A TXV 34,200 14.25 12.20 CX34-38B 7510232 14ACX-036-230A TXV 33,400 15.50 12.50 CX34-42 EL180UH070E36B 7513248 14ACX-036-230A TXV 33,400 15.50 12.50 CX34-42 EL180UH070XE36B 7513249 14ACX-036-230A TXV 33,400 15.10 12.50 CX34-42 EL180UH090E48B 7513250 14ACX-036-230A TXV 33,400 15.10 12.50 CX34-42 EL180UH090XE48B 7513251 14ACX-036-230A TXV 33,000 15.00 12.50 CX34-42 EL195UH045XE36B 7513252 14ACX-036-230A TXV 33,000 15.00 12.50 CX34-42 EL296UH045XE36B 7513253 14ACX-036-230A TXV 33,400 15.00 12.50 CX34-42 EL296UH045XV36B 7513256 14ACX-036-230A TXV 33,400 15.00 12.50 CX34-42 EL296UH070XV36B 7513257 14ACX-036-230A TXV 33,600 15.50 12.50 CX34-42 SL280UH090V36B 7513245 14ACX-036-230A TXV 33,600 15.50 12.50 CX34-42 SL280UH090V48B 7513246 14ACX-036-230A TXV 33,600 15.50 12.50 CX34-42 SL280UH090XV48B 7513247 14ACX-036-230A TXV 33,400 15.00 12.50 CX34-42 SLP98UH070XV36B 7513258 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-43B EL180UH070E36B 7510840 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-43B EL180UH070XE36B 7510841 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-43B EL180UH090E48B 7510842 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 172 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-43B EL180UH090XE48B 7510843 14ACX-036-230A TXV 34,400 15.00 12.50 CX34-43B EL195UH045XE36B 7510844 14ACX-036-230A TXV 34,600 15.10 12.50 CX34-43B EL195UH070XE36B 7510846 14ACX-036-230A TXV 34,400 15.00 12.50 CX34-43B EL296UH045XE36B 7510845 14ACX-036-230A TXV 34,800 15.50 12.50 CX34-43B EL296UH045XV36B 7510848 14ACX-036-230A TXV 34,600 15.10 12.50 CX34-43B EL296UH070XE36B 7510847 14ACX-036-230A TXV 34,800 15.50 12.50 CX34-43B EL296UH070XV36B 7510849 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-43B SL280UH090V36B 7510837 14ACX-036-230A TXV 35,000 16.00 13.00 CX34-43B SL280UH090V48B 7510838 14ACX-036-230A TXV 35,000 16.00 13.00 CX34-43B SL280UH090XV48B 7510839 14ACX-036-230A TXV 34,800 15.50 12.50 CX34-43B SLP98UH070XV36B 7510850 14ACX-036-230A TXV 34,400 14.50 12.20 CX34-43B 7510836 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-43C EL180UH090E60C 7510856 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-43C EL180UH110E60C 7510857 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-43C EL180UH110XE60C 7510858 14ACX-036-230A TXV 34,600 15.50 12.50 CX34-43C EL195UH090XE48C 7510859 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-43C EL195UH110XE60C 7510861 14ACX-036-230A TXV 34,600 15.50 12.50 CX34-43C EL296UH090XE48C 7510860 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-43C EL296UH090XV36C 7510863 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-43C EL296UH090XV48C 7510865 14ACX-036-230A TXV 34,600 16.00 13.00 CX34-43C EL296UH110XE60C 7510862 14ACX-036-230A TXV 35,000 16.00 13.00 CX34-43C EL296UH110XV48C 7510867 14ACX-036-230A TXV 35,200 16.00 13.00 CX34-43C EL296UH110XV60C 7510868 14ACX-036-230A TXV 35,400 16.00 13.00 CX34-43C SL280UH090V60C 7510852 14ACX-036-230A TXV 35,400 16.00 13.00 CX34-43C SL280UH090XV60C 7510853 14ACX-036-230A TXV 35,200 16.00 13.00 CX34-43C SL280UH110V60C 7510854 14ACX-036-230A TXV 35,200 16.00 13.00 CX34-43C SL280UH110XV60C 7510855 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-43C SLP98UH090XV36C 7510864 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-43C SLP98UH090XV48C 7510866 14ACX-036-230A TXV 35,200 16.00 13.00 CX34-43C SLP98UH110XV60C 7510869 14ACX-036-230A TXV 34,400 14.50 12.20 CX34-43C 7510851 14ACX-036-230A TXV 34,200 16.00 13.00 CX34-44/48B EL180UH070E36B 7510874 14ACX-036-230A TXV 34,200 16.00 13.00 CX34-44/48B EL180UH070XE36B 7510875 14ACX-036-230A TXV 34,200 15.50 12.50 CX34-44/48B EL180UH090E48B 7614651 14ACX-036-230A TXV 34,200 15.50 12.50 CX34-44/48B EL180UH090XE48B 7510877 14ACX-036-230A TXV 33,800 15.10 12.50 CX34-44/48B EL195UH045XE36B 7510878 14ACX-036-230A TXV 34,200 15.00 12.50 CX34-44/48B EL195UH070XE36B 7510880 14ACX-036-230A TXV 33,800 15.10 12.50 CX34-44/48B EL296UH045XE36B 7510879 14ACX-036-230A TXV 34,200 15.10 12.50 CX34-44/48B EL296UH045XV36B 7510882 14ACX-036-230A TXV 34,200 15.00 12.50 CX34-44/48B EL296UH070XE36B 7510881 14ACX-036-230A TXV 34,200 15.10 12.50 CX34-44/48B EL296UH070XV36B 7614668 14ACX-036-230A TXV 34,400 16.00 13.00 CX34-44/48B SL280UH090V36B 7510871 14ACX-036-230A TXV 34,400 16.00 13.00 CX34-44/48B SL280UH090V48B 7510872 14ACX-036-230A TXV 34,400 16.00 13.00 CX34-44/48B SL280UH090XV48B 7510873 14ACX-036-230A TXV 34,200 15.10 12.50 CX34-44/48B SLP98UH070XV36B 7510884 14ACX-036-230A TXV 34,400 15.50 12.50 CX34-44/48C EL180UH090E60C 7510890 14ACX-036-230A TXV 34,400 16.00 13.00 CX34-44/48C EL180UH110E60C 7510891 14ACX-036-230A TXV 34,400 16.00 13.00 CX34-44/48C EL180UH110XE60C 7510892 14ACX-036-230A TXV 34,200 15.50 12.50 CX34-44/48C EL195UH090XE48C 7510893 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 173 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 34,400 15.50 12.50 CX34-44/48C EL195UH110XE60C 7510895 14ACX-036-230A TXV 34,200 15.50 12.50 CX34-44/48C EL296UH090XE48C 7510894 14ACX-036-230A TXV 34,400 15.50 12.50 CX34-44/48C EL296UH090XV36C 7510897 14ACX-036-230A TXV 34,200 16.00 13.00 CX34-44/48C EL296UH090XV48C 7510899 14ACX-036-230A TXV 34,200 15.50 12.50 CX34-44/48C EL296UH110XE60C 7510896 14ACX-036-230A TXV 34,400 16.00 13.00 CX34-44/48C EL296UH110XV48C 7510901 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-44/48C EL296UH110XV60C 7510902 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-44/48C SL280UH090V60C 7510886 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-44/48C SL280UH090XV60C 7510887 14ACX-036-230A TXV 34,600 15.50 12.50 CX34-44/48C SL280UH110V60C 7510888 14ACX-036-230A TXV 34,600 15.50 12.50 CX34-44/48C SL280UH110XV60C 7510889 14ACX-036-230A TXV 34,400 15.50 12.50 CX34-44/48C SLP98UH090XV36C 7510898 14ACX-036-230A TXV 34,200 16.00 13.00 CX34-44/48C SLP98UH090XV48C 7510900 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-44/48C SLP98UH110XV60C 7510903 14ACX-036-230A TXV 35,200 16.00 13.00 CX34-49 EL180UH090E60C 7513264 14ACX-036-230A TXV 35,000 16.00 13.00 CX34-49 EL180UH110E60C 7513265 14ACX-036-230A TXV 35,000 16.00 13.00 CX34-49 EL180UH110XE60C 7513266 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-49 EL195UH090XE48C 7513267 14ACX-036-230A TXV 35,200 16.00 13.00 CX34-49 EL195UH110XE60C 7513269 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-49 EL296UH090XE48C 7513268 14ACX-036-230A TXV 35,200 16.00 13.00 CX34-49 EL296UH090XV36C 7513271 14ACX-036-230A TXV 35,000 16.00 13.00 CX34-49 EL296UH090XV48C 7513273 14ACX-036-230A TXV 35,200 16.00 13.00 CX34-49 EL296UH110XE60C 7513270 14ACX-036-230A TXV 35,200 16.00 13.00 CX34-49 EL296UH110XV48C 7513275 14ACX-036-230A TXV 35,600 16.00 13.00 CX34-49 EL296UH110XV60C 7513276 14ACX-036-230A TXV 35,600 16.00 13.00 CX34-49 SL280UH090V60C 7513260 14ACX-036-230A TXV 35,600 16.00 13.00 CX34-49 SL280UH090XV60C 7513261 14ACX-036-230A TXV 35,400 16.00 13.00 CX34-49 SL280UH110V60C 7513262 14ACX-036-230A TXV 35,400 16.00 13.00 CX34-49 SL280UH110XV60C 7513263 14ACX-036-230A TXV 35,200 16.00 13.00 CX34-49 SLP98UH090XV36C 7513272 14ACX-036-230A TXV 35,000 16.00 13.00 CX34-49 SLP98UH090XV48C 7513274 14ACX-036-230A TXV 35,600 16.00 13.00 CX34-49 SLP98UH110XV60C 7513277 14ACX-036-230A TXV 34,600 14.50 12.20 CX34-49 7513259 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-50/60C EL180UH090E60C 7510909 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-50/60C EL180UH110E60C 7510910 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-50/60C EL180UH110XE60C 7510911 14ACX-036-230A TXV 34,600 15.50 12.50 CX34-50/60C EL195UH090XE48C 7510912 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-50/60C EL195UH110XE60C 7510914 14ACX-036-230A TXV 34,600 15.50 12.50 CX34-50/60C EL296UH090XE48C 7510913 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-50/60C EL296UH090XV36C 7510916 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-50/60C EL296UH090XV48C 7510918 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-50/60C EL296UH110XE60C 7510915 14ACX-036-230A TXV 35,000 16.00 13.00 CX34-50/60C EL296UH110XV48C 7510920 14ACX-036-230A TXV 35,200 16.00 13.00 CX34-50/60C EL296UH110XV60C 7510921 14ACX-036-230A TXV 35,200 16.00 13.00 CX34-50/60C SL280UH090V60C 7510905 14ACX-036-230A TXV 35,200 16.00 13.00 CX34-50/60C SL280UH090XV60C 7510906 14ACX-036-230A TXV 35,000 16.00 13.00 CX34-50/60C SL280UH110V60C 7510907 14ACX-036-230A TXV 35,000 16.00 13.00 CX34-50/60C SL280UH110XV60C 7510908 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-50/60C SLP98UH090XV36C 7510917 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 174 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 34,800 16.00 13.00 CX34-50/60C SLP98UH090XV48C 7510919 14ACX-036-230A TXV 35,200 16.00 13.00 CX34-50/60C SLP98UH110XV60C 7510922 14ACX-036-230A TXV 34,200 14.50 12.20 CX34-50/60C 7510904 14ACX-036-230A TXV 33,200 14.50 12.20 CX35-30/36A EL180UH045E36A 8268191 14ACX-036-230A TXV 33,200 14.50 12.20 CX35-30/36A EL180UH045XE36A 8268192 14ACX-036-230A TXV 33,400 15.00 12.20 CX35-30/36A SL280UH070V36A 8268193 14ACX-036-230A TXV 33,400 15.00 12.20 CX35-30/36A SL280UH070XV36A 8268194 14ACX-036-230A TXV 33,400 15.50 12.50 CX35-30/36B EL180UH070E36B 8268206 14ACX-036-230A TXV 33,400 15.50 12.50 CX35-30/36B EL180UH070XE36B 8268198 14ACX-036-230A TXV 33,400 15.10 12.50 CX35-30/36B EL180UH090E48B 8268199 14ACX-036-230A TXV 33,400 15.10 12.50 CX35-30/36B EL180UH090XE48B 8268200 14ACX-036-230A TXV 33,000 15.00 12.50 CX35-30/36B EL195UH045XE36B 8268201 14ACX-036-230A TXV 33,000 15.00 12.50 CX35-30/36B EL296UH045XE36B 8268202 14ACX-036-230A TXV 33,400 15.00 12.50 CX35-30/36B EL296UH045XV36B 8268195 14ACX-036-230A TXV 33,400 15.00 12.50 CX35-30/36B EL296UH070XV36B 8268196 14ACX-036-230A TXV 33,600 15.50 12.50 CX35-30/36B SL280UH090V36B 8268203 14ACX-036-230A TXV 33,600 15.50 12.50 CX35-30/36B SL280UH090V48B 8268204 14ACX-036-230A TXV 33,600 15.50 12.50 CX35-30/36B SL280UH090XV48B 8268205 14ACX-036-230A TXV 33,400 15.00 12.50 CX35-30/36B SLP98UH070XV36B 8268197 14ACX-036-230A TXV 33,600 15.10 12.50 CX35-30/36C EL180UH090E60C 8268218 14ACX-036-230A TXV 33,400 15.50 12.50 CX35-30/36C EL180UH110E60C 8268219 14ACX-036-230A TXV 33,400 15.50 12.50 CX35-30/36C EL180UH110XE60C 8268212 14ACX-036-230A TXV 33,200 15.10 12.50 CX35-30/36C EL195UH090XE48C 8268213 14ACX-036-230A TXV 33,600 15.10 12.50 CX35-30/36C EL195UH110XE60C 8268215 14ACX-036-230A TXV 33,200 15.10 12.50 CX35-30/36C EL296UH090XE48C 8268214 14ACX-036-230A TXV 33,600 15.50 12.50 CX35-30/36C EL296UH090XV36C 8268217 14ACX-036-230A TXV 33,400 15.50 12.50 CX35-30/36C EL296UH090XV48C 8268209 14ACX-036-230A TXV 33,600 15.10 12.50 CX35-30/36C EL296UH110XE60C 8268216 14ACX-036-230A TXV 33,600 15.50 12.50 CX35-30/36C EL296UH110XV48C 8268211 14ACX-036-230A TXV 33,600 15.50 12.50 CX35-30/36C SLP98UH090XV36C 8268208 14ACX-036-230A TXV 33,400 15.50 12.50 CX35-30/36C SLP98UH090XV48C 8268210 14ACX-036-230A TXV 33,800 15.50 12.50 CX35-30/36C SLP98UH110XV60C 8268207 14ACX-036-230A TXV 34,200 15.10 12.50 CX35-30A EL180UH045E36A 8268173 14ACX-036-230A TXV 34,200 15.10 12.50 CX35-30A EL180UH045XE36A 8268174 14ACX-036-230A TXV 34,400 15.10 12.50 CX35-30A SL280UH070V36A 8268175 14ACX-036-230A TXV 34,400 15.10 12.50 CX35-30A SL280UH070XV36A 8268176 14ACX-036-230A TXV 34,400 15.00 12.50 CX35-30B EL180UH070E36B 8268190 14ACX-036-230A TXV 34,400 15.00 12.50 CX35-30B EL180UH070XE36B 8268181 14ACX-036-230A TXV 34,400 15.50 12.50 CX35-30B EL180UH090E48B 8268182 14ACX-036-230A TXV 34,400 15.50 12.50 CX35-30B EL180UH090XE48B 8268183 14ACX-036-230A TXV 34,000 14.50 12.20 CX35-30B EL195UH045XE36B 8268184 14ACX-036-230A TXV 34,000 15.10 12.50 CX35-30B EL195UH070XE36B 8268186 14ACX-036-230A TXV 34,000 14.50 12.20 CX35-30B EL296UH045XE36B 8268185 14ACX-036-230A TXV 34,200 15.10 12.50 CX35-30B EL296UH045XV36B 8268178 14ACX-036-230A TXV 34,000 15.10 12.50 CX35-30B EL296UH070XE36B 8268177 14ACX-036-230A TXV 34,200 15.10 12.50 CX35-30B EL296UH070XV36B 8268179 14ACX-036-230A TXV 34,400 15.50 12.50 CX35-30B SL280UH090V36B 8268187 14ACX-036-230A TXV 34,400 15.50 12.50 CX35-30B SL280UH090V48B 8268188 14ACX-036-230A TXV 34,400 15.50 12.50 CX35-30B SL280UH090XV48B 8268189 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 175 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 34,200 15.10 12.50 CX35-30B SLP98UH070XV36B 8268180 14ACX-036-230A TXV 34,400 15.10 12.50 CX35-36A EL180UH045E36A 8268221 14ACX-036-230A TXV 34,400 15.10 12.50 CX35-36A EL180UH045XE36A 8268222 14ACX-036-230A TXV 34,600 15.50 12.50 CX35-36A SL280UH070V36A 8268223 14ACX-036-230A TXV 34,600 15.50 12.50 CX35-36A SL280UH070XV36A 8268224 14ACX-036-230A TXV 34,200 14.25 12.20 CX35-36A 8268220 14ACX-036-230A TXV 34,600 16.00 13.00 CX35-36B EL180UH070E36B 8268239 14ACX-036-230A TXV 34,600 16.00 13.00 CX35-36B EL180UH070XE36B 8268230 14ACX-036-230A TXV 34,600 16.00 13.00 CX35-36B EL180UH090E48B 8268231 14ACX-036-230A TXV 34,600 16.00 13.00 CX35-36B EL180UH090XE48B 8268232 14ACX-036-230A TXV 34,400 15.00 12.50 CX35-36B EL195UH045XE36B 8268233 14ACX-036-230A TXV 34,400 15.00 12.50 CX35-36B EL195UH070XE36B 8268235 14ACX-036-230A TXV 34,400 15.00 12.50 CX35-36B EL296UH045XE36B 8268234 14ACX-036-230A TXV 34,600 15.50 12.50 CX35-36B EL296UH045XV36B 8268227 14ACX-036-230A TXV 34,400 15.00 12.50 CX35-36B EL296UH070XE36B 8268226 14ACX-036-230A TXV 34,600 15.50 12.50 CX35-36B EL296UH070XV36B 8268228 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-36B SL280UH090V36B 8268236 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-36B SL280UH090V48B 8268237 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-36B SL280UH090XV48B 8268238 14ACX-036-230A TXV 34,600 15.50 12.50 CX35-36B SLP98UH070XV36B 8268229 14ACX-036-230A TXV 34,200 14.25 12.20 CX35-36B 8268225 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-48B EL180UH070E36B 8268248 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-48B EL180UH070XE36B 8268249 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-48B EL180UH090E48B 8268250 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-48B EL180UH090XE48B 8268251 14ACX-036-230A TXV 34,400 15.00 12.50 CX35-48B EL195UH045XE36B 8268252 14ACX-036-230A TXV 34,600 15.10 12.50 CX35-48B EL195UH070XE36B 8268242 14ACX-036-230A TXV 34,400 15.00 12.50 CX35-48B EL296UH045XE36B 8268241 14ACX-036-230A TXV 34,800 15.50 12.50 CX35-48B EL296UH045XV36B 8268244 14ACX-036-230A TXV 34,600 15.10 12.50 CX35-48B EL296UH070XE36B 8268243 14ACX-036-230A TXV 34,800 15.50 12.50 CX35-48B EL296UH070XV36B 8268245 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-48B SL280UH090V36B 8268253 14ACX-036-230A TXV 35,000 16.00 13.00 CX35-48B SL280UH090V48B 8268254 14ACX-036-230A TXV 35,000 16.00 13.00 CX35-48B SL280UH090XV48B 8268247 14ACX-036-230A TXV 34,800 15.50 12.50 CX35-48B SLP98UH070XV36B 8268246 14ACX-036-230A TXV 34,400 14.50 12.20 CX35-48B 8268240 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-48C EL180UH090E60C 8268272 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-48C EL180UH110E60C 8268273 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-48C EL180UH110XE60C 8268262 14ACX-036-230A TXV 34,600 15.50 12.50 CX35-48C EL195UH090XE48C 8268263 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-48C EL195UH110XE60C 8268265 14ACX-036-230A TXV 34,600 15.50 12.50 CX35-48C EL296UH090XE48C 8268264 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-48C EL296UH090XV36C 8268267 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-48C EL296UH090XV48C 8268257 14ACX-036-230A TXV 34,600 16.00 13.00 CX35-48C EL296UH110XE60C 8268266 14ACX-036-230A TXV 35,000 16.00 13.00 CX35-48C EL296UH110XV48C 8268259 14ACX-036-230A TXV 35,200 16.00 13.00 CX35-48C EL296UH110XV60C 8268260 14ACX-036-230A TXV 35,400 16.00 13.00 CX35-48C SL280UH090V60C 8268268 14ACX-036-230A TXV 35,400 16.00 13.00 CX35-48C SL280UH090XV60C 8268269 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 176 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-036-230A TXV 35,200 16.00 13.00 CX35-48C SL280UH110V60C 8268270 14ACX-036-230A TXV 35,200 16.00 13.00 CX35-48C SL280UH110XV60C 8268271 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-48C SLP98UH090XV36C 8268256 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-48C SLP98UH090XV48C 8268258 14ACX-036-230A TXV 35,200 16.00 13.00 CX35-48C SLP98UH110XV60C 8268261 14ACX-036-230A TXV 34,400 14.50 12.20 CX35-48C 8268255 14ACX-036-230A TXV 35,200 16.00 13.00 CX35-49C EL180UH090E60C 8268287 14ACX-036-230A TXV 35,000 16.00 13.00 CX35-49C EL180UH110E60C 8268288 14ACX-036-230A TXV 35,000 16.00 13.00 CX35-49C EL180UH110XE60C 8268289 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-49C EL195UH090XE48C 8268290 14ACX-036-230A TXV 35,200 16.00 13.00 CX35-49C EL195UH110XE60C 8268280 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-49C EL296UH090XE48C 8268279 14ACX-036-230A TXV 35,200 16.00 13.00 CX35-49C EL296UH090XV36C 8268282 14ACX-036-230A TXV 35,000 16.00 13.00 CX35-49C EL296UH090XV48C 8268284 14ACX-036-230A TXV 35,200 16.00 13.00 CX35-49C EL296UH110XE60C 8268281 14ACX-036-230A TXV 35,200 16.00 13.00 CX35-49C EL296UH110XV48C 8268276 14ACX-036-230A TXV 35,600 16.00 13.00 CX35-49C EL296UH110XV60C 8268277 14ACX-036-230A TXV 35,600 16.00 13.00 CX35-49C SL280UH090V60C 8268291 14ACX-036-230A TXV 35,600 16.00 13.00 CX35-49C SL280UH090XV60C 8268292 14ACX-036-230A TXV 35,400 16.00 13.00 CX35-49C SL280UH110V60C 8268285 14ACX-036-230A TXV 35,400 16.00 13.00 CX35-49C SL280UH110XV60C 8268286 14ACX-036-230A TXV 35,200 16.00 13.00 CX35-49C SLP98UH090XV36C 8268283 14ACX-036-230A TXV 35,000 16.00 13.00 CX35-49C SLP98UH090XV48C 8268275 14ACX-036-230A TXV 35,600 16.00 13.00 CX35-49C SLP98UH110XV60C 8268278 14ACX-036-230A TXV 34,600 14.50 12.20 CX35-49C 8268274 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL180UH090E60C 8268302 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL180UH110E60C 8268303 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL180UH110XE60C 8268304 14ACX-036-230A TXV 34,400 15.50 12.50 CX35-50/60C EL195UH090XE48C 8268305 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL195UH110XE60C 8268307 14ACX-036-230A TXV 34,400 15.50 12.50 CX35-50/60C EL296UH090XE48C 8268306 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL296UH090XV36C 8268297 14ACX-036-230A TXV 34,600 16.00 13.00 CX35-50/60C EL296UH090XV48C 8268299 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL296UH110XE60C 8268296 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C EL296UH110XV48C 8268301 14ACX-036-230A TXV 35,200 16.00 13.00 CX35-50/60C EL296UH110XV60C 8268294 14ACX-036-230A TXV 35,200 16.00 13.00 CX35-50/60C SL280UH090V60C 8268308 14ACX-036-230A TXV 35,200 16.00 13.00 CX35-50/60C SL280UH090XV60C 8268309 14ACX-036-230A TXV 35,000 16.00 13.00 CX35-50/60C SL280UH110V60C 8268310 14ACX-036-230A TXV 35,000 16.00 13.00 CX35-50/60C SL280UH110XV60C 8268311 14ACX-036-230A TXV 34,800 16.00 13.00 CX35-50/60C SLP98UH090XV36C 8268298 14ACX-036-230A TXV 34,600 16.00 13.00 CX35-50/60C SLP98UH090XV48C 8268300 14ACX-036-230A TXV 35,200 16.00 13.00 CX35-50/60C SLP98UH110XV60C 8268295 14ACX-036-230A TXV 34,200 14.50 12.20 CX35-50/60C 8268293 14ACX-042-230A RFC 42,000 14.25 12.20 C33-62C 7511091 14ACX-042-230A RFC 41,500 14.00 12.20 C35-49C 8471019 14ACX-042-230A RFC 41,000 14.00 12.20 C35-60D 8471021 14ACX-042-230A RFC 41,500 14.00 12.20 CH33-43C 7513072 14ACX-042-230A RFC 42,000 14.00 12.20 CH33-49 7511217 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 177 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A RFC 41,500 14.00 12.20 CH33-50/60C 7511239 14ACX-042-230A TXV 39,500 14.50 12.20 C33-36B EL180UH090E48B 7510967 14ACX-042-230A TXV 39,500 14.50 12.20 C33-36B EL180UH090XE48B 7510968 14ACX-042-230A TXV 39,500 14.50 12.20 C33-36B SL280UH090V36B 7510961 14ACX-042-230A TXV 39,500 14.50 12.20 C33-36B SL280UH090V48B 7510962 14ACX-042-230A TXV 39,500 14.50 12.20 C33-36B SL280UH090XV48B 7510963 14ACX-042-230A TXV 39,500 14.50 12.20 C33-36C EL180UH090E60C 7510985 14ACX-042-230A TXV 39,000 14.50 12.20 C33-36C EL180UH110E60C 7510986 14ACX-042-230A TXV 39,000 14.50 12.20 C33-36C EL180UH110XE60C 7510987 14ACX-042-230A TXV 39,000 14.50 12.20 C33-36C EL195UH090XE48C 7510981 14ACX-042-230A TXV 39,500 14.50 12.20 C33-36C EL195UH110XE60C 7510983 14ACX-042-230A TXV 39,000 14.50 12.20 C33-36C EL296UH090XE48C 7510982 14ACX-042-230A TXV 39,000 14.50 12.20 C33-36C EL296UH090XV48C 7510972 14ACX-042-230A TXV 39,500 14.50 12.20 C33-36C EL296UH110XE60C 7510984 14ACX-042-230A TXV 39,500 14.50 12.20 C33-36C EL296UH110XV60C 7510976 14ACX-042-230A TXV 39,500 14.50 12.20 C33-36C SL280UH090V60C 7510977 14ACX-042-230A TXV 39,500 14.50 12.20 C33-36C SL280UH090XV60C 7510978 14ACX-042-230A TXV 39,500 14.50 12.20 C33-36C SL280UH110V60C 7510979 14ACX-042-230A TXV 39,500 14.50 12.20 C33-36C SL280UH110XV60C 7510980 14ACX-042-230A TXV 39,000 14.50 12.20 C33-36C SLP98UH090XV48C 7510971 14ACX-042-230A TXV 39,500 14.50 12.20 C33-36C SLP98UH110XV60C 7510975 14ACX-042-230A TXV 41,000 15.10 12.50 C33-38B EL180UH090E48B 7510994 14ACX-042-230A TXV 41,000 15.10 12.50 C33-38B EL180UH090XE48B 7510995 14ACX-042-230A TXV 40,500 14.50 12.20 C33-38B EL296UH045XV36B 7510996 14ACX-042-230A TXV 40,500 14.50 12.20 C33-38B EL296UH070XV36B 7510990 14ACX-042-230A TXV 41,000 15.10 12.50 C33-38B SL280UH090V36B 7510991 14ACX-042-230A TXV 41,000 15.10 12.50 C33-38B SL280UH090V48B 7510992 14ACX-042-230A TXV 41,000 15.10 12.50 C33-38B SL280UH090XV48B 7510993 14ACX-042-230A TXV 40,500 14.50 12.20 C33-38B SLP98UH070XV36B 7510989 14ACX-042-230A TXV 39,500 14.50 12.20 C33-42 EL180UH090E48B 7511003 14ACX-042-230A TXV 39,500 14.50 12.20 C33-42 EL180UH090XE48B 7511004 14ACX-042-230A TXV 39,500 14.50 12.20 C33-42 SL280UH090V36B 7511000 14ACX-042-230A TXV 39,500 14.50 12.20 C33-42 SL280UH090V48B 7511001 14ACX-042-230A TXV 39,500 14.50 12.20 C33-42 SL280UH090XV48B 7511002 14ACX-042-230A TXV 41,500 15.50 12.50 C33-43B EL180UH090E48B 7511012 14ACX-042-230A TXV 41,500 15.50 12.50 C33-43B EL180UH090XE48B 7511013 14ACX-042-230A TXV 41,000 14.50 12.20 C33-43B EL296UH045XV36B 7511006 14ACX-042-230A TXV 41,000 14.50 12.20 C33-43B EL296UH070XV36B 7511008 14ACX-042-230A TXV 41,000 15.10 12.50 C33-43B SL280UH090V36B 7511009 14ACX-042-230A TXV 41,500 15.10 12.50 C33-43B SL280UH090V48B 7511010 14ACX-042-230A TXV 41,500 15.10 12.50 C33-43B SL280UH090XV48B 7511011 14ACX-042-230A TXV 41,000 14.50 12.20 C33-43B SLP98UH070XV36B 7511007 14ACX-042-230A TXV 41,500 15.50 12.50 C33-43C EL180UH090E60C 7511028 14ACX-042-230A TXV 41,500 15.50 12.50 C33-43C EL180UH110E60C 7511029 14ACX-042-230A TXV 41,500 15.50 12.50 C33-43C EL180UH110XE60C 7511030 14ACX-042-230A TXV 41,000 15.50 12.50 C33-43C EL195UH090XE48C 7511031 14ACX-042-230A TXV 41,500 15.50 12.50 C33-43C EL195UH110XE60C 7511033 14ACX-042-230A TXV 41,000 15.50 12.50 C33-43C EL296UH090XE48C 7511032 14ACX-042-230A TXV 41,000 15.10 12.50 C33-43C EL296UH090XV36C 7511016 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 178 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 41,000 15.10 12.50 C33-43C EL296UH090XV48C 7511018 14ACX-042-230A TXV 41,500 15.10 12.50 C33-43C EL296UH090XV60C 7511021 14ACX-042-230A TXV 41,500 15.50 12.50 C33-43C EL296UH110XE60C 7511034 14ACX-042-230A TXV 41,500 15.10 12.50 C33-43C EL296UH110XV48C 7511019 14ACX-042-230A TXV 41,500 15.50 12.50 C33-43C EL296UH110XV60C 7511023 14ACX-042-230A TXV 41,500 15.50 12.50 C33-43C SL280UH090V60C 7511024 14ACX-042-230A TXV 41,500 15.50 12.50 C33-43C SL280UH090XV60C 7511025 14ACX-042-230A TXV 41,500 15.50 12.50 C33-43C SL280UH110V60C 7511026 14ACX-042-230A TXV 41,500 15.50 12.50 C33-43C SL280UH110XV60C 7511027 14ACX-042-230A TXV 41,000 15.10 12.50 C33-43C SLP98UH090XV36C 7511015 14ACX-042-230A TXV 41,000 15.10 12.50 C33-43C SLP98UH090XV48C 7511017 14ACX-042-230A TXV 41,500 15.10 12.50 C33-43C SLP98UH090XV60C 7511020 14ACX-042-230A TXV 41,500 15.50 12.50 C33-43C SLP98UH110XV60C 7511022 14ACX-042-230A TXV 40,500 15.10 12.50 C33-48B EL180UH090E48B 7511039 14ACX-042-230A TXV 40,500 15.10 12.50 C33-48B EL180UH090XE48B 7511040 14ACX-042-230A TXV 40,500 14.50 12.20 C33-48B EL296UH045XV36B 7511036 14ACX-042-230A TXV 40,500 15.00 12.50 C33-48B SL280UH090V36B 7511041 14ACX-042-230A TXV 40,500 15.00 12.50 C33-48B SL280UH090V48B 7511042 14ACX-042-230A TXV 40,500 15.00 12.50 C33-48B SL280UH090XV48B 7511043 14ACX-042-230A TXV 41,000 15.10 12.50 C33-48C EL180UH090E60C 7511045 14ACX-042-230A TXV 40,500 15.10 12.50 C33-48C EL180UH110E60C 7511046 14ACX-042-230A TXV 40,500 15.10 12.50 C33-48C EL180UH110XE60C 7511047 14ACX-042-230A TXV 40,500 15.10 12.50 C33-48C EL195UH090XE48C 7511048 14ACX-042-230A TXV 41,000 15.10 12.50 C33-48C EL195UH110XE60C 7511049 14ACX-042-230A TXV 40,500 15.10 12.50 C33-48C EL296UH090XE48C 7511050 14ACX-042-230A TXV 40,500 15.00 12.50 C33-48C EL296UH090XV36C 7511051 14ACX-042-230A TXV 40,500 15.10 12.50 C33-48C EL296UH090XV48C 7511052 14ACX-042-230A TXV 41,000 15.00 12.50 C33-48C EL296UH090XV60C 7511053 14ACX-042-230A TXV 41,000 15.10 12.50 C33-48C EL296UH110XE60C 7511054 14ACX-042-230A TXV 40,500 15.10 12.50 C33-48C EL296UH110XV48C 7511055 14ACX-042-230A TXV 40,500 15.10 12.50 C33-48C EL296UH110XV60C 7511056 14ACX-042-230A TXV 41,000 15.10 12.50 C33-48C SL280UH090V60C 7511057 14ACX-042-230A TXV 41,000 15.10 12.50 C33-48C SL280UH090XV60C 7511058 14ACX-042-230A TXV 40,500 15.00 12.50 C33-48C SL280UH110V60C 7511059 14ACX-042-230A TXV 40,500 15.00 12.50 C33-48C SL280UH110XV60C 7511060 14ACX-042-230A TXV 40,500 15.00 12.50 C33-48C SLP98UH090XV36C 7511062 14ACX-042-230A TXV 40,500 15.10 12.50 C33-48C SLP98UH090XV48C 7511063 14ACX-042-230A TXV 41,000 15.00 12.50 C33-48C SLP98UH090XV60C 7511061 14ACX-042-230A TXV 40,500 15.10 12.50 C33-48C SLP98UH110XV60C 7511064 14ACX-042-230A TXV 42,000 16.00 13.00 C33-49 EL180UH090E60C 7513052 14ACX-042-230A TXV 42,000 16.00 13.00 C33-49 EL180UH110E60C 7513053 14ACX-042-230A TXV 42,000 16.00 13.00 C33-49 EL180UH110XE60C 7513054 14ACX-042-230A TXV 41,500 15.50 12.50 C33-49 EL195UH090XE48C 7513055 14ACX-042-230A TXV 42,000 15.50 12.50 C33-49 EL195UH110XE60C 7513056 14ACX-042-230A TXV 41,500 15.50 12.50 C33-49 EL296UH090XE48C 7513057 14ACX-042-230A TXV 41,500 15.50 12.50 C33-49 EL296UH090XV36C 7513058 14ACX-042-230A TXV 41,500 15.50 12.50 C33-49 EL296UH090XV48C 7513059 14ACX-042-230A TXV 42,000 15.50 12.50 C33-49 EL296UH090XV60C 7513060 14ACX-042-230A TXV 42,000 15.50 12.50 C33-49 EL296UH110XE60C 7513061 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 179 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 42,000 15.50 12.50 C33-49 EL296UH110XV48C 7513062 14ACX-042-230A TXV 42,000 15.50 12.50 C33-49 EL296UH110XV60C 7513063 14ACX-042-230A TXV 42,000 16.00 13.00 C33-49 SL280UH090V60C 7513064 14ACX-042-230A TXV 42,000 16.00 13.00 C33-49 SL280UH090XV60C 7513065 14ACX-042-230A TXV 42,000 15.50 12.50 C33-49 SL280UH110V60C 7513066 14ACX-042-230A TXV 42,000 15.50 12.50 C33-49 SL280UH110XV60C 7513067 14ACX-042-230A TXV 41,500 15.50 12.50 C33-49 SLP98UH090XV36C 7513068 14ACX-042-230A TXV 41,500 15.50 12.50 C33-49 SLP98UH090XV48C 7513069 14ACX-042-230A TXV 42,000 15.50 12.50 C33-49 SLP98UH090XV60C 7513070 14ACX-042-230A TXV 42,000 15.50 12.50 C33-49 SLP98UH110XV60C 7513071 14ACX-042-230A TXV 41,500 14.25 12.20 C33-49 7513051 14ACX-042-230A TXV 41,000 15.50 12.50 C33-50/60C EL180UH090E60C 7511066 14ACX-042-230A TXV 41,000 15.50 12.50 C33-50/60C EL180UH110E60C 7511067 14ACX-042-230A TXV 41,000 15.50 12.50 C33-50/60C EL180UH110XE60C 7511068 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C EL195UH090XE48C 7511069 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C EL195UH110XE60C 7511070 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH090XE48C 7511071 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH090XV36C 7511072 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH090XV48C 7511073 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH090XV60C 7511074 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH110XE60C 7511075 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH110XV48C 7511076 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C EL296UH110XV60C 7511077 14ACX-042-230A TXV 41,500 15.10 12.50 C33-50/60C SL280UH090V60C 7511078 14ACX-042-230A TXV 41,500 15.10 12.50 C33-50/60C SL280UH090XV60C 7511079 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C SL280UH110V60C 7511080 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C SL280UH110XV60C 7511081 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C SLP98UH090XV36C 7511082 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C SLP98UH090XV48C 7511083 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C SLP98UH090XV60C 7511084 14ACX-042-230A TXV 41,000 15.10 12.50 C33-50/60C SLP98UH110XV60C 7511085 14ACX-042-230A TXV 40,500 14.00 12.20 C33-50/60C 9143755 14ACX-042-230A TXV 42,000 16.00 13.00 C33-60D EL180UH135E60D 7511087 14ACX-042-230A TXV 42,000 15.50 12.50 C33-60D EL195UH135XE60D 7511088 14ACX-042-230A TXV 42,000 15.50 12.50 C33-60D EL296UH135XE60D 7511089 14ACX-042-230A TXV 42,000 16.00 13.00 C33-60D SL280UH135V60D 7511090 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C EL180UH090E60C 7511093 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C EL180UH110E60C 7511094 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C EL180UH110XE60C 7511095 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C EL195UH090XE48C 7511096 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C EL195UH110XE60C 7511097 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH090XE48C 7511098 14ACX-042-230A TXV 42,000 15.50 12.50 C33-62C EL296UH090XV36C 7511099 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH090XV48C 7511100 14ACX-042-230A TXV 42,000 15.50 12.50 C33-62C EL296UH090XV60C 7511101 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH110XE60C 7511102 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH110XV48C 7511103 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C EL296UH110XV60C 7511104 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C SL280UH090V60C 7511105 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 180 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C SL280UH090XV60C 7511106 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C SL280UH110V60C 7511107 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C SL280UH110XV60C 7511108 14ACX-042-230A TXV 42,000 15.50 12.50 C33-62C SLP98UH090XV36C 7511109 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C SLP98UH090XV48C 7511110 14ACX-042-230A TXV 42,000 15.50 12.50 C33-62C SLP98UH090XV60C 7511111 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62C SLP98UH110XV60C 7511112 14ACX-042-230A TXV 42,000 14.25 12.20 C33-62C 7511092 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62D EL180UH135E60D 7511114 14ACX-042-230A TXV 42,000 15.50 12.50 C33-62D EL195UH135XE60D 7511115 14ACX-042-230A TXV 42,000 15.50 12.50 C33-62D EL296UH135XE60D 7511116 14ACX-042-230A TXV 42,000 16.00 13.00 C33-62D SL280UH135V60D 7511117 14ACX-042-230A TXV 41,500 14.50 12.50 C33-62D 9143756 14ACX-042-230A TXV 41,500 14.25 12.20 C33-62D 7511113 14ACX-042-230A TXV 39,500 14.50 12.20 C35-30/36B EL180UH090E48B 8267691 14ACX-042-230A TXV 39,500 14.50 12.20 C35-30/36B EL180UH090XE48B 8267692 14ACX-042-230A TXV 39,500 14.50 12.20 C35-30/36B SL280UH090V36B 8267688 14ACX-042-230A TXV 39,500 14.50 12.20 C35-30/36B SL280UH090V48B 8267689 14ACX-042-230A TXV 39,500 14.50 12.20 C35-30/36B SL280UH090XV48B 8267690 14ACX-042-230A TXV 39,500 14.50 12.20 C35-30/36C EL180UH090E60C 8267693 14ACX-042-230A TXV 39,000 14.50 12.20 C35-30/36C EL180UH110E60C 8267694 14ACX-042-230A TXV 39,000 14.50 12.20 C35-30/36C EL180UH110XE60C 8267695 14ACX-042-230A TXV 39,000 14.50 12.20 C35-30/36C EL195UH090XE48C 8267698 14ACX-042-230A TXV 39,500 14.50 12.20 C35-30/36C EL195UH110XE60C 8267700 14ACX-042-230A TXV 39,000 14.50 12.20 C35-30/36C EL296UH090XE48C 8267699 14ACX-042-230A TXV 39,000 14.50 12.20 C35-30/36C EL296UH090XV36C 9143757 14ACX-042-230A TXV 39,000 14.50 12.20 C35-30/36C EL296UH090XV48C 8267707 14ACX-042-230A TXV 39,500 14.50 12.50 C35-30/36C EL296UH090XV60C 9143758 14ACX-042-230A TXV 39,500 14.50 12.20 C35-30/36C EL296UH110XE60C 8267701 14ACX-042-230A TXV 39,500 14.50 12.20 C35-30/36C EL296UH110XV60C 8267703 14ACX-042-230A TXV 39,500 14.50 12.20 C35-30/36C SL280UH090V60C 8267704 14ACX-042-230A TXV 39,500 14.50 12.20 C35-30/36C SL280UH090XV60C 8267705 14ACX-042-230A TXV 39,500 14.50 12.20 C35-30/36C SL280UH110V60C 8267696 14ACX-042-230A TXV 39,500 14.50 12.20 C35-30/36C SL280UH110XV60C 8267697 14ACX-042-230A TXV 39,000 14.50 12.20 C35-30/36C SLP98UH090XV36C 9143759 14ACX-042-230A TXV 39,000 14.50 12.20 C35-30/36C SLP98UH090XV48C 8267706 14ACX-042-230A TXV 39,500 14.50 12.50 C35-30/36C SLP98UH090XV60C 9143760 14ACX-042-230A TXV 39,500 14.50 12.20 C35-30/36C SLP98UH110XV60C 8267702 14ACX-042-230A TXV 41,000 15.10 12.50 C35-36B EL180UH090E48B 8267710 14ACX-042-230A TXV 41,000 15.10 12.50 C35-36B EL180UH090XE48B 8267711 14ACX-042-230A TXV 40,500 14.50 12.20 C35-36B EL296UH045XV36B 8267712 14ACX-042-230A TXV 40,500 14.50 12.20 C35-36B EL296UH070XV36B 8267714 14ACX-042-230A TXV 41,000 15.10 12.50 C35-36B SL280UH090V36B 8267715 14ACX-042-230A TXV 41,000 15.10 12.50 C35-36B SL280UH090V48B 8267708 14ACX-042-230A TXV 41,000 15.10 12.50 C35-36B SL280UH090XV48B 8267709 14ACX-042-230A TXV 40,500 14.50 12.20 C35-36B SLP98UH070XV36B 8267713 14ACX-042-230A TXV 41,500 15.50 12.50 C35-48B EL180UH090E48B 8267717 14ACX-042-230A TXV 41,500 15.50 12.50 C35-48B EL180UH090XE48B 8267718 14ACX-042-230A TXV 41,000 14.50 12.20 C35-48B EL296UH045XV36B 8267719 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 181 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 41,000 14.50 12.20 C35-48B EL296UH070XV36B 8267721 14ACX-042-230A TXV 41,000 15.10 12.50 C35-48B SL280UH090V36B 8267722 14ACX-042-230A TXV 41,500 15.10 12.50 C35-48B SL280UH090V48B 8267723 14ACX-042-230A TXV 41,500 15.10 12.50 C35-48B SL280UH090XV48B 8267716 14ACX-042-230A TXV 41,000 14.50 12.20 C35-48B SLP98UH070XV36B 8267720 14ACX-042-230A TXV 41,500 15.50 12.50 C35-48C EL180UH090E60C 8267733 14ACX-042-230A TXV 41,500 15.50 12.50 C35-48C EL180UH110E60C 8267734 14ACX-042-230A TXV 41,500 15.50 12.50 C35-48C EL180UH110XE60C 8267724 14ACX-042-230A TXV 41,000 15.50 12.50 C35-48C EL195UH090XE48C 8267725 14ACX-042-230A TXV 41,500 15.50 12.50 C35-48C EL195UH110XE60C 8267727 14ACX-042-230A TXV 41,000 15.50 12.50 C35-48C EL296UH090XE48C 8267726 14ACX-042-230A TXV 41,000 15.10 12.50 C35-48C EL296UH090XV36C 8267742 14ACX-042-230A TXV 41,000 15.10 12.50 C35-48C EL296UH090XV48C 8267735 14ACX-042-230A TXV 41,500 15.10 12.50 C35-48C EL296UH090XV60C 8267738 14ACX-042-230A TXV 41,500 15.50 12.50 C35-48C EL296UH110XE60C 8267728 14ACX-042-230A TXV 41,500 15.10 12.50 C35-48C EL296UH110XV48C 8267736 14ACX-042-230A TXV 41,500 15.50 12.50 C35-48C EL296UH110XV60C 8267740 14ACX-042-230A TXV 41,500 15.50 12.50 C35-48C SL280UH090V60C 8267729 14ACX-042-230A TXV 41,500 15.50 12.50 C35-48C SL280UH090XV60C 8267730 14ACX-042-230A TXV 41,500 15.50 12.50 C35-48C SL280UH110V60C 8267731 14ACX-042-230A TXV 41,500 15.50 12.50 C35-48C SL280UH110XV60C 8267732 14ACX-042-230A TXV 41,000 15.10 12.50 C35-48C SLP98UH090XV36C 8267741 14ACX-042-230A TXV 41,000 15.10 12.50 C35-48C SLP98UH090XV48C 8267743 14ACX-042-230A TXV 41,500 15.10 12.50 C35-48C SLP98UH090XV60C 8267737 14ACX-042-230A TXV 41,500 15.50 12.50 C35-48C SLP98UH110XV60C 8267739 14ACX-042-230A TXV 42,000 16.00 13.00 C35-49C EL180UH090E60C 8267764 14ACX-042-230A TXV 42,000 16.00 13.00 C35-49C EL180UH110E60C 8267758 14ACX-042-230A TXV 42,000 16.00 13.00 C35-49C EL180UH110XE60C 8267759 14ACX-042-230A TXV 41,500 15.50 12.50 C35-49C EL195UH090XE48C 8267760 14ACX-042-230A TXV 42,000 15.50 12.50 C35-49C EL195UH110XE60C 8267761 14ACX-042-230A TXV 41,500 15.50 12.50 C35-49C EL296UH090XE48C 8267762 14ACX-042-230A TXV 41,500 15.50 12.50 C35-49C EL296UH090XV36C 8267763 14ACX-042-230A TXV 41,500 15.50 12.50 C35-49C EL296UH090XV48C 8267752 14ACX-042-230A TXV 42,000 15.50 12.50 C35-49C EL296UH090XV60C 8267753 14ACX-042-230A TXV 42,000 15.50 12.50 C35-49C EL296UH110XE60C 8267754 14ACX-042-230A TXV 42,000 15.50 12.50 C35-49C EL296UH110XV48C 8267755 14ACX-042-230A TXV 42,000 15.50 12.50 C35-49C EL296UH110XV60C 8267756 14ACX-042-230A TXV 42,000 16.00 13.00 C35-49C SL280UH090V60C 8267757 14ACX-042-230A TXV 42,000 16.00 13.00 C35-49C SL280UH090XV60C 8267746 14ACX-042-230A TXV 42,000 15.50 12.50 C35-49C SL280UH110V60C 8267747 14ACX-042-230A TXV 42,000 15.50 12.50 C35-49C SL280UH110XV60C 8267748 14ACX-042-230A TXV 41,500 15.50 12.50 C35-49C SLP98UH090XV36C 8267749 14ACX-042-230A TXV 41,500 15.50 12.50 C35-49C SLP98UH090XV48C 8267750 14ACX-042-230A TXV 42,000 15.50 12.50 C35-49C SLP98UH090XV60C 8267751 14ACX-042-230A TXV 42,000 15.50 12.50 C35-49C SLP98UH110XV60C 8267745 14ACX-042-230A TXV 41,500 14.25 12.20 C35-49C 8267744 14ACX-042-230A TXV 41,000 15.50 12.50 C35-50/60C EL180UH090E60C 8267782 14ACX-042-230A TXV 41,000 15.50 12.50 C35-50/60C EL180UH110E60C 8267783 14ACX-042-230A TXV 41,000 15.50 12.50 C35-50/60C EL180UH110XE60C 8267784 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 182 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C EL195UH090XE48C 8267776 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C EL195UH110XE60C 8267777 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH090XE48C 8267778 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH090XV36C 8267779 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH090XV48C 8267780 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH090XV60C 8267781 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH110XE60C 8267770 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH110XV48C 8267771 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C EL296UH110XV60C 8267772 14ACX-042-230A TXV 41,500 15.10 12.50 C35-50/60C SL280UH090V60C 8267773 14ACX-042-230A TXV 41,500 15.10 12.50 C35-50/60C SL280UH090XV60C 8267774 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C SL280UH110V60C 8267775 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C SL280UH110XV60C 8267765 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C SLP98UH090XV36C 8267766 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C SLP98UH090XV48C 8267767 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C SLP98UH090XV60C 8267768 14ACX-042-230A TXV 41,000 15.10 12.50 C35-50/60C SLP98UH110XV60C 8267769 14ACX-042-230A TXV 40,500 14.50 12.20 C35-50/60C 9143761 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C EL180UH090E60C 8267803 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C EL180UH110E60C 8267804 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C EL180UH110XE60C 8267805 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C EL195UH090XE48C 8267797 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C EL195UH110XE60C 8267798 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH090XE48C 8267799 14ACX-042-230A TXV 42,000 15.50 12.50 C35-60C EL296UH090XV36C 8267800 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH090XV48C 8267801 14ACX-042-230A TXV 42,000 15.50 12.50 C35-60C EL296UH090XV60C 8267802 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH110XE60C 8267791 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH110XV48C 8267792 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C EL296UH110XV60C 8267793 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C SL280UH090V60C 8267794 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C SL280UH090XV60C 8267795 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C SL280UH110V60C 8267796 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C SL280UH110XV60C 8267786 14ACX-042-230A TXV 42,000 15.50 12.50 C35-60C SLP98UH090XV36C 8267787 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C SLP98UH090XV48C 8267788 14ACX-042-230A TXV 42,000 15.50 12.50 C35-60C SLP98UH090XV60C 8267789 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60C SLP98UH110XV60C 8267790 14ACX-042-230A TXV 42,000 14.25 12.20 C35-60C 8267785 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60D EL180UH135E60D 8267810 14ACX-042-230A TXV 42,000 15.50 12.50 C35-60D EL195UH135XE60D 8267807 14ACX-042-230A TXV 42,000 15.50 12.50 C35-60D EL296UH135XE60D 8267808 14ACX-042-230A TXV 42,000 16.00 13.00 C35-60D SL280UH135V60D 8267809 14ACX-042-230A TXV 41,500 14.25 12.20 C35-60D 8267806 14ACX-042-230A TXV 41,500 15.50 12.50 CBA27UHE-042 10259380 14ACX-042-230A TXV 41,500 15.50 12.50 CBA27UHE-048 10259381 14ACX-042-230A TXV 41,500 14.00 12.20 CBX25UH-042 7511120 14ACX-042-230A TXV 42,000 14.50 12.50 CBX25UH-048 7511121 14ACX-042-230A TXV 42,000 15.10 12.50 CBX25UHV-042 7511122 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 183 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 42,000 15.50 12.50 CBX25UHV-048 7511123 14ACX-042-230A TXV 41,500 15.50 12.50 CBX27UH-042 7511118 14ACX-042-230A TXV 42,000 15.10 12.50 CBX27UH-048 7511119 14ACX-042-230A TXV 40,500 14.00 12.20 CBX32M-042 7511124 14ACX-042-230A TXV 41,500 14.25 12.20 CBX32M-048 7511125 14ACX-042-230A TXV 42,000 15.10 12.50 CBX32MV-048 7511126 14ACX-042-230A TXV 42,000 15.00 12.50 CBX40UHV-042 7511127 14ACX-042-230A TXV 42,000 15.00 12.50 CBX40UHV-048 7511128 14ACX-042-230A TXV 40,500 15.10 12.50 CH23-51 EL180UH090E60C 7511129 14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 EL180UH110E60C 7511130 14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 EL180UH110XE60C 7511131 14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 EL296UH090XV48C 7511132 14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 EL296UH090XV60C 7511133 14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 EL296UH110XV48C 7511134 14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 EL296UH110XV60C 7511135 14ACX-042-230A TXV 40,500 15.10 12.50 CH23-51 SL280UH090V60C 7511136 14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 SL280UH110V60C 7511137 14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 SL280UH110XV60C 7511138 14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 SLP98UH090XV48C 7511139 14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 SLP98UH090XV60C 7511140 14ACX-042-230A TXV 40,000 15.10 12.50 CH23-51 SLP98UH110XV60C 7511141 14ACX-042-230A TXV 40,500 15.50 12.50 CH23-65 EL180UH090E60C 7511142 14ACX-042-230A TXV 40,500 15.50 12.50 CH23-65 EL180UH110E60C 7511143 14ACX-042-230A TXV 40,500 15.50 12.50 CH23-65 EL180UH110XE60C 7511144 14ACX-042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH090XV48C 7511145 14ACX-042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH090XV60C 7511146 14ACX-042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH110XV48C 7511147 14ACX-042-230A TXV 40,500 15.10 12.50 CH23-65 EL296UH110XV60C 7511148 14ACX-042-230A TXV 41,000 15.50 12.50 CH23-65 SL280UH090V60C 7511149 14ACX-042-230A TXV 40,500 15.50 12.50 CH23-65 SL280UH110V60C 7511150 14ACX-042-230A TXV 40,500 15.50 12.50 CH23-65 SL280UH110XV60C 7511151 14ACX-042-230A TXV 40,500 15.10 12.50 CH23-65 SLP98UH090XV48C 7511152 14ACX-042-230A TXV 40,500 15.10 12.50 CH23-65 SLP98UH090XV60C 7511153 14ACX-042-230A TXV 40,500 15.10 12.50 CH23-65 SLP98UH110XV60C 7511154 14ACX-042-230A TXV 40,500 15.10 12.50 CH33-42 EL180UH090E48B 7511155 14ACX-042-230A TXV 40,500 15.10 12.50 CH33-42 EL180UH090XE48B 7511156 14ACX-042-230A TXV 40,500 15.00 12.50 CH33-42 SL280UH090V36B 7511158 14ACX-042-230A TXV 40,500 15.00 12.50 CH33-42 SL280UH090V48B 7511159 14ACX-042-230A TXV 40,500 15.00 12.50 CH33-42 SL280UH090XV48B 7511160 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-43B EL180UH090E48B 8565947 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-43B EL180UH090XE48B 8565948 14ACX-042-230A TXV 41,500 15.00 12.50 CH33-43B EL296UH045XV36B 7511162 14ACX-042-230A TXV 41,500 15.00 12.50 CH33-43B EL296UH070XV36B 7511164 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-43B SL280UH090V36B 7511165 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-43B SL280UH090V48B 7511166 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-43B SL280UH090XV48B 7511167 14ACX-042-230A TXV 41,500 15.00 12.50 CH33-43B SLP98UH070XV36B 7511163 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL180UH090E60C 7511170 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL180UH110E60C 7511171 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 184 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL180UH110XE60C 7511172 14ACX-042-230A TXV 41,000 15.50 12.50 CH33-43C EL195UH090XE48C 7511173 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL195UH110XE60C 7511174 14ACX-042-230A TXV 41,000 15.50 12.50 CH33-43C EL296UH090XE48C 7511175 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH090XV36C 7511176 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH090XV48C 7511177 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH090XV60C 7511178 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH110XE60C 7511179 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH110XV48C 7511180 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C EL296UH110XV60C 7511181 14ACX-042-230A TXV 42,000 16.00 13.00 CH33-43C SL280UH090V60C 7511182 14ACX-042-230A TXV 42,000 16.00 13.00 CH33-43C SL280UH090XV60C 7511183 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C SL280UH110V60C 7511184 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C SL280UH110XV60C 7511185 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH090XV36C 7511186 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH090XV48C 7511187 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH090XV60C 7511188 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-43C SLP98UH110XV60C 7511189 14ACX-042-230A TXV 41,500 14.00 12.20 CH33-43C 7511169 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-44/48B EL180UH090E48B 7511190 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-44/48B EL180UH090XE48B 7511191 14ACX-042-230A TXV 40,500 14.50 12.20 CH33-44/48B EL296UH070XV36B 7511192 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-44/48B SL280UH090V36B 7511193 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-44/48B SL280UH090V48B 7511194 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-44/48B SL280UH090XV48B 7511195 14ACX-042-230A TXV 40,500 14.50 12.20 CH33-44/48B SLP98UH070XV36B 9150351 14ACX-042-230A TXV 41,000 15.50 12.50 CH33-48C EL180UH090E60C 7511197 14ACX-042-230A TXV 41,000 15.50 12.50 CH33-48C EL180UH110E60C 7511198 14ACX-042-230A TXV 41,000 15.50 12.50 CH33-48C EL180UH110XE60C 7511199 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C EL195UH090XE48C 7511200 14ACX-042-230A TXV 41,500 15.10 12.50 CH33-48C EL195UH110XE60C 7511201 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH090XE48C 7511202 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH090XV36C 7511203 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH090XV48C 7511204 14ACX-042-230A TXV 41,500 15.10 12.50 CH33-48C EL296UH090XV60C 7511205 14ACX-042-230A TXV 41,500 15.10 12.50 CH33-48C EL296UH110XE60C 7511206 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH110XV48C 7511207 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C EL296UH110XV60C 7511208 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-48C SL280UH090V60C 7511209 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-48C SL280UH090XV60C 7511210 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C SL280UH110V60C 7511211 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C SL280UH110XV60C 7511212 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C SLP98UH090XV36C 7511213 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C SLP98UH090XV48C 7511214 14ACX-042-230A TXV 41,500 15.10 12.50 CH33-48C SLP98UH090XV60C 7511215 14ACX-042-230A TXV 41,000 15.10 12.50 CH33-48C SLP98UH110XV60C 7511216 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL180UH090E60C 7511219 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL180UH110E60C 7511220 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL180UH110XE60C 7511221 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 185 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-49 EL195UH090XE48C 7511222 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL195UH110XE60C 7511223 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-49 EL296UH090XE48C 7511224 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-49 EL296UH090XV36C 7511225 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH090XV48C 7511226 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH090XV60C 7511227 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH110XE60C 7511228 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH110XV48C 7511229 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 EL296UH110XV60C 7511230 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 SL280UH090V60C 7511231 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 SL280UH090XV60C 7511232 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 SL280UH110V60C 7511233 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 SL280UH110XV60C 7511234 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-49 SLP98UH090XV36C 7511235 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 SLP98UH090XV48C 7511236 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 SLP98UH090XV60C 7511237 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-49 SLP98UH110XV60C 7511238 14ACX-042-230A TXV 42,000 14.00 12.20 CH33-49 7511218 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL180UH090E60C 7511241 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL180UH110E60C 7511242 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL180UH110XE60C 7511243 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL195UH090XE48C 7511244 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-50/60C EL195UH110XE60C 7511245 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL296UH090XE48C 7511246 14ACX-042-230A TXV 41,500 15.10 12.50 CH33-50/60C EL296UH090XV36C 7511247 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL296UH090XV48C 7511248 14ACX-042-230A TXV 42,000 15.10 12.50 CH33-50/60C EL296UH090XV60C 7511249 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-50/60C EL296UH110XE60C 7511250 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL296UH110XV48C 7511251 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-50/60C EL296UH110XV60C 7511252 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-50/60C SL280UH090V60C 7511253 14ACX-042-230A TXV 42,000 15.50 12.50 CH33-50/60C SL280UH090XV60C 7511254 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-50/60C SL280UH110V60C 7511255 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-50/60C SL280UH110XV60C 7511256 14ACX-042-230A TXV 41,500 15.10 12.50 CH33-50/60C SLP98UH090XV36C 7511257 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-50/60C SLP98UH090XV48C 7511258 14ACX-042-230A TXV 42,000 15.10 12.50 CH33-50/60C SLP98UH090XV60C 7511259 14ACX-042-230A TXV 41,500 15.50 12.50 CH33-50/60C SLP98UH110XV60C 7511260 14ACX-042-230A TXV 41,500 14.00 12.20 CH33-50/60C 7511240 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-42B EL180UH090E48B 7511261 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-42B EL180UH090XE48B 7511262 14ACX-042-230A TXV 42,000 15.10 12.50 CH35-42B EL296UH045XV36B 7511263 14ACX-042-230A TXV 41,500 15.00 12.50 CH35-42B EL296UH070XV36B 7511264 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-42B SL280UH090V36B 7511265 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-42B SL280UH090V48B 7511266 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-42B SL280UH090XV48B 7511267 14ACX-042-230A TXV 41,500 15.00 12.50 CH35-42B SLP98UH070XV36B 7511268 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-42C EL180UH090E60C 7511270 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-42C EL180UH110E60C 7511271 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 186 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-42C EL180UH110XE60C 7511272 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-42C EL195UH090XE48C 7511273 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-42C EL195UH110XE60C 7511274 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-42C EL296UH090XE48C 7511275 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-42C EL296UH090XV36C 7511276 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-42C EL296UH090XV48C 7511277 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-42C EL296UH090XV60C 7511278 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-42C EL296UH110XE60C 7511279 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-42C EL296UH110XV48C 7511280 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-42C EL296UH110XV60C 7511281 14ACX-042-230A TXV 42,000 16.00 13.00 CH35-42C SL280UH090V60C 7511282 14ACX-042-230A TXV 42,000 16.00 13.00 CH35-42C SL280UH090XV60C 7511283 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-42C SL280UH110V60C 7511284 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-42C SL280UH110XV60C 7511285 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-42C SLP98UH090XV36C 7511286 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-42C SLP98UH090XV48C 7511287 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-42C SLP98UH090XV60C 7511288 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-42C SLP98UH110XV60C 7511289 14ACX-042-230A TXV 41,500 14.00 12.20 CH35-42C 7511269 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-48B EL180UH090E48B 7511290 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-48B EL180UH090XE48B 7511291 14ACX-042-230A TXV 41,000 14.50 12.20 CH35-48B EL296UH045XV36B 7511292 14ACX-042-230A TXV 41,000 14.50 12.20 CH35-48B EL296UH070XV36B 7511293 14ACX-042-230A TXV 41,500 15.10 12.50 CH35-48B SL280UH090V36B 7511294 14ACX-042-230A TXV 41,500 15.10 12.50 CH35-48B SL280UH090V48B 7511295 14ACX-042-230A TXV 41,500 15.10 12.50 CH35-48B SL280UH090XV48B 7511296 14ACX-042-230A TXV 41,000 14.50 12.20 CH35-48B SLP98UH070XV36B 7511297 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-48C EL180UH090E60C 7511299 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-48C EL180UH110E60C 7511300 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-48C EL180UH110XE60C 7511301 14ACX-042-230A TXV 41,000 15.10 12.50 CH35-48C EL195UH090XE48C 7511302 14ACX-042-230A TXV 41,500 15.10 12.50 CH35-48C EL195UH110XE60C 7511303 14ACX-042-230A TXV 41,000 15.10 12.50 CH35-48C EL296UH090XE48C 7511304 14ACX-042-230A TXV 41,000 15.10 12.50 CH35-48C EL296UH090XV36C 7511305 14ACX-042-230A TXV 41,500 15.10 12.50 CH35-48C EL296UH090XV48C 7511306 14ACX-042-230A TXV 41,500 15.10 12.50 CH35-48C EL296UH090XV60C 7511307 14ACX-042-230A TXV 41,500 15.10 12.50 CH35-48C EL296UH110XE60C 7511308 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-48C EL296UH110XV48C 7511309 14ACX-042-230A TXV 41,500 15.10 12.50 CH35-48C EL296UH110XV60C 7511310 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-48C SL280UH090V60C 7511311 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-48C SL280UH090XV60C 7511312 14ACX-042-230A TXV 41,500 15.10 12.50 CH35-48C SL280UH110V60C 7511313 14ACX-042-230A TXV 41,500 15.10 12.50 CH35-48C SL280UH110XV60C 7511314 14ACX-042-230A TXV 41,000 15.10 12.50 CH35-48C SLP98UH090XV36C 7511315 14ACX-042-230A TXV 41,500 15.10 12.50 CH35-48C SLP98UH090XV48C 7511316 14ACX-042-230A TXV 41,500 15.10 12.50 CH35-48C SLP98UH090XV60C 7511317 14ACX-042-230A TXV 41,500 15.10 12.50 CH35-48C SLP98UH110XV60C 7511318 14ACX-042-230A TXV 41,500 14.00 12.20 CH35-48C 7511298 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C EL180UH090E48B 10040431 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 187 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C EL180UH090E60C 7511320 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C EL180UH110E60C 7511321 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C EL180UH110XE60C 7511322 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-51C EL195UH090XE48C 7511323 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C EL195UH110XE60C 7511324 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-51C EL296UH090XE48C 7511325 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-51C EL296UH090XV36C 7511326 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C EL296UH090XV48C 7511327 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C EL296UH090XV60C 7511328 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C EL296UH110XE60C 7511329 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C EL296UH110XV48C 7511330 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C EL296UH110XV60C 7511331 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C SL280UH090V60C 7511332 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C SL280UH090XV60C 7511333 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C SL280UH110V60C 7511334 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C SL280UH110XV60C 7511335 14ACX-042-230A TXV 41,500 15.50 12.50 CH35-51C SLP98UH090XV36C 7511336 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C SLP98UH090XV48C 7511337 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C SLP98UH090XV60C 7511338 14ACX-042-230A TXV 42,000 15.50 12.50 CH35-51C SLP98UH110XV60C 7511339 14ACX-042-230A TXV 42,000 14.00 12.20 CH35-51C 7511319 14ACX-042-230A TXV 40,500 15.10 12.50 CR33-48 EL180DF110E60C 7511341 14ACX-042-230A TXV 40,500 15.10 12.50 CR33-48 EL195DF090XE48C 7511342 14ACX-042-230A TXV 40,500 15.10 12.50 CR33-48 EL195DF110XE60C 7511343 14ACX-042-230A TXV 40,500 15.10 12.50 CR33-48 EL296DF090XE48C 7511344 14ACX-042-230A TXV 40,500 15.00 12.20 CR33-48 EL296DF090XV60C 7511345 14ACX-042-230A TXV 40,500 15.10 12.50 CR33-48 EL296DF110XE60C 7511346 14ACX-042-230A TXV 40,500 14.50 12.20 CR33-48 SL280DF090V48B 7511340 14ACX-042-230A TXV 40,500 15.10 12.50 CR33-48 SL280DF090V60C 7511347 14ACX-042-230A TXV 40,500 15.10 12.50 CR33-48 SL280DF110V60C 7511348 14ACX-042-230A TXV 40,500 15.10 12.50 CR33-48 SLP98DF090XV36C 9143762 14ACX-042-230A TXV 40,500 15.00 12.20 CR33-48 SLP98DF090XV60C 7511350 14ACX-042-230A TXV 41,500 15.50 12.50 CR33-50/60 EL180DF110E60C 7511351 14ACX-042-230A TXV 41,000 15.10 12.50 CR33-50/60 EL195DF090XE48C 7511352 14ACX-042-230A TXV 41,500 15.50 12.50 CR33-50/60 EL195DF110XE60C 7511353 14ACX-042-230A TXV 41,000 15.10 12.50 CR33-50/60 EL296DF090XE48C 7511354 14ACX-042-230A TXV 41,500 15.10 12.50 CR33-50/60 EL296DF090XV60C 7511355 14ACX-042-230A TXV 41,500 15.50 12.50 CR33-50/60 EL296DF110XE60C 7511356 14ACX-042-230A TXV 41,500 15.50 12.50 CR33-50/60 EL296DF110XV60C 7511357 14ACX-042-230A TXV 41,000 15.50 12.50 CR33-50/60 SL280DF090V60C 7511358 14ACX-042-230A TXV 41,500 15.50 12.50 CR33-50/60 SL280DF110V60C 7511359 14ACX-042-230A TXV 41,000 15.10 12.50 CR33-50/60 SLP98DF090XV36C 7511360 14ACX-042-230A TXV 41,000 15.10 12.50 CR33-50/60 SLP98DF090XV48C 7511361 14ACX-042-230A TXV 41,500 15.10 12.50 CR33-50/60 SLP98DF090XV60C 7511362 14ACX-042-230A TXV 41,500 15.50 12.50 CR33-50/60 SLP98DF110XV60C 7511363 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-36B EL180UH090E48B 7511370 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-36B EL180UH090XE48B 7511371 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-36B SL280UH090V36B 7511364 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-36B SL280UH090V48B 7511365 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 188 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-36B SL280UH090XV48B 7511366 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-36C EL180UH090E60C 7511372 14ACX-042-230A TXV 39,000 14.50 12.20 CX34-36C EL180UH110E60C 7511373 14ACX-042-230A TXV 39,000 14.50 12.20 CX34-36C EL180UH110XE60C 7511374 14ACX-042-230A TXV 39,000 14.50 12.20 CX34-36C EL195UH090XE48C 7511375 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-36C EL195UH110XE60C 7511376 14ACX-042-230A TXV 39,000 14.50 12.20 CX34-36C EL296UH090XE48C 7511377 14ACX-042-230A TXV 39,000 14.50 12.20 CX34-36C EL296UH090XV48C 7511379 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-36C EL296UH110XE60C 7511381 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-36C EL296UH110XV60C 7511382 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-36C SL280UH090V60C 7511383 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-36C SL280UH090XV60C 7511384 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-36C SL280UH110V60C 7511385 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-36C SL280UH110XV60C 7511386 14ACX-042-230A TXV 39,000 14.50 12.20 CX34-36C SLP98UH090XV48C 7511388 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-36C SLP98UH110XV60C 7511390 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-38B EL180UH090E48B 7511392 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-38B EL180UH090XE48B 7511393 14ACX-042-230A TXV 40,500 14.50 12.20 CX34-38B EL296UH045XV36B 7511394 14ACX-042-230A TXV 40,500 14.50 12.20 CX34-38B EL296UH070XV36B 7511395 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-38B SL280UH090V36B 7511396 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-38B SL280UH090V48B 7511397 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-38B SL280UH090XV48B 7511398 14ACX-042-230A TXV 40,500 14.50 12.20 CX34-38B SLP98UH070XV36B 7511399 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-42 EL180UH090E48B 7511400 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-42 EL180UH090XE48B 7511401 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-42 SL280UH090V36B 7511404 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-42 SL280UH090V48B 7511405 14ACX-042-230A TXV 39,500 14.50 12.20 CX34-42 SL280UH090XV48B 7511406 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-43B EL180UH090E48B 7511409 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-43B EL180UH090XE48B 7511410 14ACX-042-230A TXV 41,000 14.50 12.20 CX34-43B EL296UH045XV36B 7511411 14ACX-042-230A TXV 41,000 14.50 12.20 CX34-43B EL296UH070XV36B 7511412 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-43B SL280UH090V36B 7511413 14ACX-042-230A TXV 41,500 15.10 12.50 CX34-43B SL280UH090V48B 7511414 14ACX-042-230A TXV 41,500 15.10 12.50 CX34-43B SL280UH090XV48B 7511415 14ACX-042-230A TXV 41,000 14.50 12.20 CX34-43B SLP98UH070XV36B 7511416 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-43C EL180UH090E60C 7511418 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-43C EL180UH110E60C 7511419 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-43C EL180UH110XE60C 7511420 14ACX-042-230A TXV 41,000 15.50 12.50 CX34-43C EL195UH090XE48C 7511421 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-43C EL195UH110XE60C 7511422 14ACX-042-230A TXV 41,000 15.50 12.50 CX34-43C EL296UH090XE48C 7511423 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-43C EL296UH090XV36C 7511424 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-43C EL296UH090XV48C 7511425 14ACX-042-230A TXV 41,500 15.10 12.50 CX34-43C EL296UH090XV60C 7511426 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-43C EL296UH110XE60C 7511427 14ACX-042-230A TXV 41,500 15.10 12.50 CX34-43C EL296UH110XV48C 7511428 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-43C EL296UH110XV60C 7511429 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 189 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-43C SL280UH090V60C 7511430 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-43C SL280UH090XV60C 7511431 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-43C SL280UH110V60C 7511432 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-43C SL280UH110XV60C 7511433 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-43C SLP98UH090XV36C 7511434 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-43C SLP98UH090XV48C 7511435 14ACX-042-230A TXV 41,500 15.10 12.50 CX34-43C SLP98UH090XV60C 7511436 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-43C SLP98UH110XV60C 7511437 14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48B EL180UH090E48B 7511439 14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48B EL180UH090XE48B 7511440 14ACX-042-230A TXV 40,500 14.50 12.20 CX34-44/48B EL296UH045XV36B 7511441 14ACX-042-230A TXV 40,500 15.00 12.50 CX34-44/48B SL280UH090V36B 7511443 14ACX-042-230A TXV 40,500 15.00 12.50 CX34-44/48B SL280UH090V48B 7511444 14ACX-042-230A TXV 40,500 15.00 12.50 CX34-44/48B SL280UH090XV48B 7511445 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-44/48C EL180UH090E60C 7511448 14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL180UH110E60C 7511449 14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL180UH110XE60C 7511450 14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL195UH090XE48C 7511451 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-44/48C EL195UH110XE60C 7511453 14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH090XE48C 7511452 14ACX-042-230A TXV 40,500 15.00 12.50 CX34-44/48C EL296UH090XV36C 7511455 14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH090XV48C 7511456 14ACX-042-230A TXV 41,000 15.00 12.50 CX34-44/48C EL296UH090XV60C 7511457 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-44/48C EL296UH110XE60C 7511454 14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH110XV48C 7511458 14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C EL296UH110XV60C 7511459 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-44/48C SL280UH090V60C 7511460 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-44/48C SL280UH090XV60C 7511461 14ACX-042-230A TXV 40,500 15.00 12.50 CX34-44/48C SL280UH110V60C 7511462 14ACX-042-230A TXV 40,500 15.00 12.50 CX34-44/48C SL280UH110XV60C 7511463 14ACX-042-230A TXV 40,500 15.00 12.50 CX34-44/48C SLP98UH090XV36C 7511464 14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C SLP98UH090XV48C 7511465 14ACX-042-230A TXV 41,000 15.00 12.50 CX34-44/48C SLP98UH090XV60C 7511466 14ACX-042-230A TXV 40,500 15.10 12.50 CX34-44/48C SLP98UH110XV60C 7511467 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-49 EL180UH090E60C 7511469 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-49 EL180UH110E60C 7511470 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-49 EL180UH110XE60C 7511471 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-49 EL195UH090XE48C 7511472 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 EL195UH110XE60C 7511473 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-49 EL296UH090XE48C 7511474 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-49 EL296UH090XV36C 7511475 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-49 EL296UH090XV48C 7511476 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 EL296UH090XV60C 7511477 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 EL296UH110XE60C 7511478 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 EL296UH110XV48C 7511479 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 EL296UH110XV60C 7511480 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-49 SL280UH090V60C 7511481 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-49 SL280UH090XV60C 7511482 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 SL280UH110V60C 7511483 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 190 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 SL280UH110XV60C 7511484 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-49 SLP98UH090XV36C 7511485 14ACX-042-230A TXV 41,500 15.50 12.50 CX34-49 SLP98UH090XV48C 7511486 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 SLP98UH090XV60C 7511487 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-49 SLP98UH110XV60C 7511488 14ACX-042-230A TXV 41,500 14.25 12.20 CX34-49 7511468 14ACX-042-230A TXV 41,000 15.50 12.50 CX34-50/60C EL180UH090E60C 7511490 14ACX-042-230A TXV 41,000 15.50 12.50 CX34-50/60C EL180UH110E60C 7511491 14ACX-042-230A TXV 41,000 15.50 12.50 CX34-50/60C EL180UH110XE60C 7511492 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL195UH090XE48C 7511493 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL195UH110XE60C 7511494 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH090XE48C 7511495 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH090XV36C 7511496 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH090XV48C 7511497 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH090XV60C 7511498 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH110XE60C 7511499 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH110XV48C 7511500 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C EL296UH110XV60C 7511501 14ACX-042-230A TXV 41,500 15.10 12.50 CX34-50/60C SL280UH090V60C 7511502 14ACX-042-230A TXV 41,500 15.10 12.50 CX34-50/60C SL280UH090XV60C 7511503 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C SL280UH110V60C 7511504 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C SL280UH110XV60C 7511505 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C SLP98UH090XV36C 7511506 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C SLP98UH090XV48C 7511507 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C SLP98UH090XV60C 7511508 14ACX-042-230A TXV 41,000 15.10 12.50 CX34-50/60C SLP98UH110XV60C 7511509 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-60D EL180UH135E60D 7511511 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-60D EL195UH135XE60D 7511512 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-60D EL296UH135XE60D 7511513 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-60D SL280UH135V60D 7511514 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C EL180UH090E60C 7511516 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C EL180UH110E60C 7511517 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C EL180UH110XE60C 7511518 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C EL195UH090XE48C 7511519 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C EL195UH110XE60C 7511520 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C EL296UH090XE48C 7511521 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-62C EL296UH090XV36C 7511522 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C EL296UH090XV48C 7511523 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-62C EL296UH090XV60C 7511524 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C EL296UH110XE60C 7511525 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C EL296UH110XV60C 7511526 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C SL280UH090V60C 7511527 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C SL280UH090XV60C 7511528 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C SL280UH110V60C 7511529 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C SL280UH110XV60C 7511530 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-62C SLP98UH090XV36C 7511531 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C SLP98UH090XV48C 7511532 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-62C SLP98UH090XV60C 7511533 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62C SLP98UH110XV60C 7511534 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 191 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 42,000 14.25 12.20 CX34-62C 7511515 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62D EL180UH135E60D 7511536 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-62D EL195UH135XE60D 7511537 14ACX-042-230A TXV 42,000 15.50 12.50 CX34-62D EL296UH135XE60D 7511538 14ACX-042-230A TXV 42,000 16.00 13.00 CX34-62D SL280UH135V60D 7511539 14ACX-042-230A TXV 41,500 14.50 12.20 CX34-62D 7511535 14ACX-042-230A TXV 39,500 14.50 12.20 CX35-30/36B EL180UH090E48B 8267811 14ACX-042-230A TXV 39,500 14.50 12.20 CX35-30/36B EL180UH090XE48B 8267812 14ACX-042-230A TXV 39,500 14.50 12.20 CX35-30/36B SL280UH090V36B 8267813 14ACX-042-230A TXV 39,500 14.50 12.20 CX35-30/36B SL280UH090V48B 8267814 14ACX-042-230A TXV 39,500 14.50 12.20 CX35-30/36B SL280UH090XV48B 8267815 14ACX-042-230A TXV 39,500 14.50 12.20 CX35-30/36C EL180UH090E60C 8267828 14ACX-042-230A TXV 39,000 14.50 12.20 CX35-30/36C EL180UH110E60C 8267829 14ACX-042-230A TXV 39,000 14.50 12.20 CX35-30/36C EL180UH110XE60C 8267830 14ACX-042-230A TXV 39,000 14.50 12.20 CX35-30/36C EL195UH090XE48C 8267824 14ACX-042-230A TXV 39,500 14.50 12.20 CX35-30/36C EL195UH110XE60C 8267825 14ACX-042-230A TXV 39,000 14.50 12.20 CX35-30/36C EL296UH090XE48C 8267826 14ACX-042-230A TXV 39,000 14.50 12.20 CX35-30/36C EL296UH090XV36C 9143763 14ACX-042-230A TXV 39,000 14.50 12.20 CX35-30/36C EL296UH090XV48C 8267827 14ACX-042-230A TXV 39,500 14.50 12.50 CX35-30/36C EL296UH090XV60C 9143764 14ACX-042-230A TXV 39,500 14.50 12.20 CX35-30/36C EL296UH110XE60C 8267818 14ACX-042-230A TXV 39,500 14.50 12.20 CX35-30/36C EL296UH110XV60C 8267819 14ACX-042-230A TXV 39,500 14.50 12.20 CX35-30/36C SL280UH090V60C 8267820 14ACX-042-230A TXV 39,500 14.50 12.20 CX35-30/36C SL280UH090XV60C 8267821 14ACX-042-230A TXV 39,500 14.50 12.20 CX35-30/36C SL280UH110V60C 8267822 14ACX-042-230A TXV 39,500 14.50 12.20 CX35-30/36C SL280UH110XV60C 8267823 14ACX-042-230A TXV 39,000 14.50 12.20 CX35-30/36C SLP98UH090XV36C 9143765 14ACX-042-230A TXV 39,000 14.50 12.20 CX35-30/36C SLP98UH090XV48C 8267816 14ACX-042-230A TXV 39,500 14.50 12.50 CX35-30/36C SLP98UH090XV60C 9143766 14ACX-042-230A TXV 39,500 14.50 12.20 CX35-30/36C SLP98UH110XV60C 8267817 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-36B EL180UH090E48B 8267837 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-36B EL180UH090XE48B 8267838 14ACX-042-230A TXV 40,500 14.50 12.20 CX35-36B EL296UH045XV36B 8267831 14ACX-042-230A TXV 40,500 14.50 12.20 CX35-36B EL296UH070XV36B 8267832 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-36B SL280UH090V36B 8267833 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-36B SL280UH090V48B 8267834 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-36B SL280UH090XV48B 8267835 14ACX-042-230A TXV 40,500 14.50 12.20 CX35-36B SLP98UH070XV36B 8267836 14ACX-042-230A TXV 41,000 14.50 12.20 CX35-36B 9143767 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-48B EL180UH090E48B 8267843 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-48B EL180UH090XE48B 8267844 14ACX-042-230A TXV 41,000 14.50 12.20 CX35-48B EL296UH045XV36B 8267845 14ACX-042-230A TXV 41,000 14.50 12.20 CX35-48B EL296UH070XV36B 8267846 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-48B SL280UH090V36B 8267839 14ACX-042-230A TXV 41,500 15.10 12.50 CX35-48B SL280UH090V48B 8267840 14ACX-042-230A TXV 41,500 15.10 12.50 CX35-48B SL280UH090XV48B 8267841 14ACX-042-230A TXV 41,000 14.50 12.20 CX35-48B SLP98UH070XV36B 8267842 14ACX-042-230A TXV 41,000 14.50 12.20 CX35-48B 9143768 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-48C EL180UH090E60C 8267865 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 192 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-48C EL180UH110E60C 8267866 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-48C EL180UH110XE60C 8267859 14ACX-042-230A TXV 41,000 15.50 12.50 CX35-48C EL195UH090XE48C 8267860 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-48C EL195UH110XE60C 8267861 14ACX-042-230A TXV 41,000 15.50 12.50 CX35-48C EL296UH090XE48C 8267862 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-48C EL296UH090XV36C 8267863 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-48C EL296UH090XV48C 8267864 14ACX-042-230A TXV 41,500 15.10 12.50 CX35-48C EL296UH090XV60C 8267853 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-48C EL296UH110XE60C 8267854 14ACX-042-230A TXV 41,500 15.10 12.50 CX35-48C EL296UH110XV48C 8267855 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-48C EL296UH110XV60C 8267856 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-48C SL280UH090V60C 8267857 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-48C SL280UH090XV60C 8267858 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-48C SL280UH110V60C 8267847 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-48C SL280UH110XV60C 8267848 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-48C SLP98UH090XV36C 8267849 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-48C SLP98UH090XV48C 8267850 14ACX-042-230A TXV 41,500 15.10 12.50 CX35-48C SLP98UH090XV60C 8267851 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-48C SLP98UH110XV60C 8267852 14ACX-042-230A TXV 41,000 14.50 12.20 CX35-48C 9143769 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-49C EL180UH090E60C 8267886 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-49C EL180UH110E60C 8267887 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-49C EL180UH110XE60C 8267880 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-49C EL195UH090XE48C 8267881 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-49C EL195UH110XE60C 8267882 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-49C EL296UH090XE48C 8267883 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-49C EL296UH090XV36C 8267884 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-49C EL296UH090XV48C 8267885 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-49C EL296UH090XV60C 8267874 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-49C EL296UH110XE60C 8267875 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-49C EL296UH110XV48C 8267876 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-49C EL296UH110XV60C 8267877 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-49C SL280UH090V60C 8267878 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-49C SL280UH090XV60C 8267879 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-49C SL280UH110V60C 8267868 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-49C SL280UH110XV60C 8267869 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-49C SLP98UH090XV36C 8267870 14ACX-042-230A TXV 41,500 15.50 12.50 CX35-49C SLP98UH090XV48C 8267871 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-49C SLP98UH090XV60C 8267872 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-49C SLP98UH110XV60C 8267873 14ACX-042-230A TXV 41,500 14.25 12.20 CX35-49C 8267867 14ACX-042-230A TXV 41,000 15.00 12.50 CX35-50/60C EL180UH090E48B 10040430 14ACX-042-230A TXV 41,000 15.50 12.50 CX35-50/60C EL180UH090E60C 8267902 14ACX-042-230A TXV 41,000 15.50 12.50 CX35-50/60C EL180UH110E60C 8267903 14ACX-042-230A TXV 41,000 15.50 12.50 CX35-50/60C EL180UH110XE60C 8267904 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL195UH090XE48C 8267905 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL195UH110XE60C 8267906 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL296UH090XE48C 8267907 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL296UH090XV36C 8267896 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 14ACX - 1.5 to 5 Ton Air Conditioner / Page 193 AHRI SYSTEM MATCHES - SOUTHWEST REGION - 018-024-030-036-042 NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org Model No. Expansion Device Capacity SEER EER Coil or Air Handler Furnace AHRI Reference 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL296UH090XV48C 8267897 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL296UH090XV60C 8267898 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL296UH110XE60C 8267899 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL296UH110XV48C 8267900 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C EL296UH110XV60C 8267901 14ACX-042-230A TXV 41,500 15.10 12.50 CX35-50/60C SL280UH090V60C 8267890 14ACX-042-230A TXV 41,500 15.10 12.50 CX35-50/60C SL280UH090XV60C 8267891 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C SL280UH110V60C 8267892 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C SL280UH110XV60C 8267893 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C SLP98UH090XV36C 8267894 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C SLP98UH090XV48C 8267895 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C SLP98UH090XV60C 8267888 14ACX-042-230A TXV 41,000 15.10 12.50 CX35-50/60C SLP98UH110XV60C 8267889 14ACX-042-230A TXV 40,500 14.50 12.20 CX35-50/60C 9143770 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C EL180UH090E60C 8267921 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C EL180UH110E60C 8267922 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C EL180UH110XE60C 8267923 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C EL195UH090XE48C 8267924 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C EL195UH110XE60C 8267925 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C EL296UH090XE48C 8267926 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-60C EL296UH090XV36C 8267915 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C EL296UH090XV48C 8267916 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-60C EL296UH090XV60C 8267917 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C EL296UH110XE60C 8267918 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C EL296UH110XV60C 8267919 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C SL280UH090V60C 8267920 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C SL280UH090XV60C 8267909 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C SL280UH110V60C 8267910 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C SL280UH110XV60C 8267911 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-60C SLP98UH090XV36C 8267912 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C SLP98UH090XV48C 8267913 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-60C SLP98UH090XV60C 8267914 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60C SLP98UH110XV60C 8267908 14ACX-042-230A TXV 42,000 15.10 12.50 CX35-60C 9143771 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60D EL180UH135E60D 8267928 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-60D EL195UH135XE60D 8267929 14ACX-042-230A TXV 42,000 15.50 12.50 CX35-60D EL296UH135XE60D 8267930 14ACX-042-230A TXV 42,000 16.00 13.00 CX35-60D SL280UH135V60D 8267931 14ACX-042-230A TXV 41,500 14.50 12.20 CX35-60D 8267927 NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed. Also see Expansion Valve Kit Usage Table. 06/06/17 06/06/17 06/06/17 NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2017 Lennox Industries, Inc. Visit us at www.lennox.com For the latest technical information, www.LennoxPROs.com Contact us at 1-800-4-LENNOX REVISIONS Sections Description of Change AHRI System Matches Updated - New CBA27UHE Air Handler matches added. Optional Accessories Removed discontinued Mounting Base.06/06/17