Loading...
HomeMy WebLinkAboutB17-0187_B17-0187 fireplace cut sheet_1494949020.pdf Pour demander un exemplaire en franpais de ce Manuel Atilii' du proprietaire, visitez www.heatnglo.com. HEAT GLO.. Owner's Manual ,� 4 ` ��* Installation and Operation No one builds a better fireModels: j'' GAS-FIRED 6000CLX-IPI-T 6000CLX-IPILP-T 6000CLX-IPI-S C 13 US 6000CLX-IPILP-S 8000CLX-IPI-T LISTED 8000CLX-IPILP-T 8000CLX-IPI-S NI.Ho• ., 8000CLX-IPILP-S ir NOTICE �aO DO NOT DISCARD THIS MANUAL SCq o?' ■�i� Important operating Read,understand and follow Leave this manual with O 1 ■ ■ and maintenance these instructionsforsafe party responsible for use instructions included. installation and operation. and operation. A WARNING: NI FIRE OR EXPLOSION HAZARD • Failure to follow safety warnings exactly could result in serious injury, death, or HOT GLASS WILL property damage. CAUSE BURNS. DO NOT TOUCH GLASS • DO NOT store or use gasoline or other flam- ,� UNTIL COOLED. mable vapors and liquids in the vicinity of this or any other appliance. NEVER ALLOW CHILDREN TO TOUCH GLASS. • What to do if you smell gas A barrier designed to reduce the risk of - DO NOT try to light any appliance. burns from the hot viewing glass is provided - DO NOT touch any electrical switch. DO with this appliance and shall be installed for NOT use any phone in your building. the protection of children and other at-risk - Leave the building immediately. individuals. - Immediately call your gas supplier from a neighbor's phone. Follow the gas sup This appliance may be installed as an OEM plier's instructions. installation in manufactured home (USA - If you cannot reach your gas supplier, call only) or mobile home and must be installed the fire department. in accordance with the manufacturer's instructions and the Manufactured Home • Installation and service must be performed Construction and Safety Standard, Title 24 by a qualified installer, service agency, or the gas supplier. CFR, Part 3280 in the United States, or the Standard for Installation in Mobile Homes, CAN/CSA Z240 MH Series, in Canada. In the Commonwealth of Massachusetts installation must be This appliance is only for use with the type(s) performed by a licensed plumber or gas fitter. of gas indicated on the rating plate. This See Table of Contents for location of additional Commonwealth appliance is not convertible for use with other of Massachusetts requirements. gases, unless a certified kit is used. Heat&Glo • 6000CLX-IPI-S.6000CLX-IPI-T.8000CLX-S,8000CLX-IPI-T • 2166-900 Rev.AQ • 2/17 1 1 Listing and Code Approvals A. Appliance Certification D. High Altitude Installations NOTICE:If the heating value of the gas has been reduced, MODELS:6000CLX-IPI, 6000CLX-IPILP, 8000CLX-IPI, these rules do not apply. Check with your local gas utility 8000CLX-IPILP or authorities having jurisdiction. LABORATORY:Underwriters Laboratories, Inc. (UL) When installing above 2000 feet elevation: TYPE:Direct Vent Heater STANDARD:ANSI Z21.88-2014• CSA 2.33-2014 • In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet. This product is listed to ANSI standards for "Vented Gas • In CANADA: Reduce input rate 10% for elevations Fireplace Heaters" and applicable sections of"Gas Burn- between 2000 feet and 4500 feet. Above 4500 feet, ing Heating Appliances for Manufactured Homes and consult local gas utility. Recreational Vehicles", and "Gas Fired Appliances for Check with your local gas utility to determine proper Use at High Altitudes". orifice size. NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI 2223.1-latest edition in E. Non-Combustible Materials Specification the U.S.A. and the CAN/CGA B149 Installation Codes in Material which will not ignite and burn. Such materials are Canada. those consisting entirely of steel, iron, brick,tile, concrete, slate, glass or plasters, or any combination thereof. NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE. Materials that are reported as passing ASTM E 136, This appliance is tested and approved as either supplemen- Standard Test Method for Behavior of Materials in tal room heat or as a decorative appliance. It should not be a Vertical Tube Furnace at 750 °C shall be considered factored as primary heat in residential heating calculations. non-combustible materials. F. Combustible Materials Specification B. Glass Specifications Materials made of or surfaced with wood, compressed pa- This appliance is equipped with 5 mm ceramic glass. Re- per, plant fibers, plastics, or other material that can ignite place glass only with 5 mm ceramic glass. Please contact and burn. whether flame proofed or not, or plastered or your dealer for replacement glass. unplastered shall be considered combustible materials. G. Electrical Codes C. BTU Specifications NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA Models Maximum Minimum Orifice 70-latest edition or the Canadian Electric Code CSA Input Input Size (U.S. or Canada) BTU/h BTU/h (DMS) C22.1. US 40.000 22,000 0.124 in • A 110-120 VAC circuit for this product must be protected with (0-2000 FT) 6000CLX-IPI (NG) - - ground-fault circuit-interrupter protection, in compliance CANADA 36,000 19,800 32 with theapplicable electrical codes,when it is installed in (2000-4500 FT) us locations such as in bathrooms or near sinks. (0-2000 FT) 40,000 21,000 49 6000CLX-IPILP CANADA 36,000 18,900 50 (2000-4500 FT) US 45.000 22,000 30 (0-2000 FT) 8000CLX-IPI (NG) CANADA 40,500 19,800 31 (2000-4500 FT) US 45,000 23.000 47 8000CLX-IPILP (0-2000 FT) CANADA 40,500 20,700 48 (2000-4500 FT) Heat&Glo • 6000CLX-IPI-S,6000CLX-IPI-T.8000CLX-S,8000CLX-IPI-T • 2166-900 Rev.AQ • 2/17 7 Inspection Note: The following requirements reference various Massachusetts and national codes not contained in this The state or local gas inspector of the side wall horizon- document. tally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed H. Requirements for the Commonwealth of in accordance with the provisions of 248 CMR 5.08(2)(a)1 Massachusetts through 4. For all side wall horizontally vented gas fueled equipment Exemptions installed in every dwelling, building or structure used in whole or in part for residential purposes, including those The following equipment is exempt from 248 CMR owned or operated by the Commonwealth and where the 5.08(2)(a)1 through 4: side wall exhaust vent termination is less than seven (7) • The equipment listed in Chapter 10 entitled "Equipment feet above finished grade in the area of the venting, in Not Required To Be Vented" in the most current edition cluding but not limited to decks and porches, the following of NFPA 54 as adopted by the Board; and requirements shall be satisfied: • Product Approved side wall horizontally vented gas fu- Installation of Carbon Monoxide Detectors eled equipment installed in a room or structure separate At the time of installation of the side wall horizontal vented from the dwelling, building or structure used in whole or gas fueled equipment, the installing plumber or gas fitter in part for residential purposes. shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor MANUFACTURER REQUIREMENTS level where the gas equipment is to be installed. In addi- Gas Equipment Venting System Provided tion, the installing plumber or gas fitter shall observe that a battery operated or hard wired carbon monoxide detec- When the manufacturer of Product Approved side wall tor with an alarm is installed on each additional level of horizontally vented gas equipment provides a venting the dwelling, building or structure served by the side wall system design or venting system components with the horizontal vented gas fueled equipment. It shall be the equipment, the instructions provided by the manufacturer responsibility of the property owner to secure the services for installation of the equipment and the venting system of qualified licensed professionals for the installation of shall include: hard wired carbon monoxide detectors. • Detailed instructions for the installation of the venting In the event that the side wall horizontally vented gas fu- system design or the venting system components; and eled equipment is installed in a crawl space or an attic, • A complete parts list for the venting system design or the hard wired carbon monoxide detector with alarm and venting system. battery back-up may be installed on the next adjacent floor level. Gas Equipment Venting System NOT Provided In the event that the requirements of this subdivision can When the manufacturer of a Product Approved side wall not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply horizontally vented gas fueled equipment does not pro- with the above requirements; provided, however, that dur- ing said thirty (30) day period, a battery operated carbon "special venting systems", the following requirements monoxide detector with an alarm shall be installed. shall be satisfied by the manufacturer: Approved Carbon Monoxide Detectors • The referenced "special venting system" instructions shall be included with the appliance or equipment in- Each carbon monoxide detector as required in accor- stallation instructions; and dance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. • The "special venting systems" shall be Product Ap- proved by the Board, and the instructions for that sys- Signage tern shall include a parts list and detailed installation A metal or plastic identification plate shall be permanent- instructions. ly mounted to the exterior of the building at a minimum height of eight(8)feet above grade directly in line with the A copy of all installation instructions for all Product Ap exhaust vent terminal for the horizontally vented gas fu- proved side wall horizontally vented gas fueled equip eled heating appliance or equipment. The sign shall read, ment, all venting instructions, all parts lists for venting in print size no less than one-half(1/2) in. in size, "GAS instructions, and/or all venting design instructions shall VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- remain with the appliance or equipment at the completion STRUCTIONS". of the installation. See Gas Connection section for additional Common- wealth of Massachusetts requirements. 8 Heat&Glo • 6000CLX-IPI-S,6000CLX-IPI-T.8000CLX-S,8000CLX-IPI-T • 2166-900 Rev.AQ • 2/17