Loading...
HomeMy WebLinkAboutB17-0198_A1.0_1497031980.pdf- An Exceptional Experience - P.O. Box 1952 Edwards, CO 81632 (970) 926-3202 fosterltd.com Project: Manor Vail Unit #348 Renovation 595 East Vail Valley Drive, Unit 212A Vail, CO 81657 Parcel #: 2101-081-05-010 Project # 17.003 Date: REVISED May 19, 2017 Owner: Frison Family LLC. PO Box 1169, Manchester, VT 05255 (703) 759-5257 Marily Hand 802 362 2310 mfhand@sover.net Contractor: Foster Construction Ltd. PO Box 1952 Edwards, CO 81632 (970) 926-3202, bfoster@fosterltd.com / sbainbridge@fosterltd.com Drawings: Foster Sketch Plans Sheet # Description A1.0 Cover Page A1.1 As -Built Floor Plan A1.2 As-Built Reflected Ceiling Plan A1.3 New Reflected Ceiling Plan Adding 6, 4 inch LED Can Lights A1.4 New Door Plan A2.1 Assemblies A2.2 Can Light Assemblies E1 Electrical Load Calculations Type of Construction: VA Occupancy Classification: R-2 Proposed Area: No Change to Existing Allowable Height per tale 503: 4 stories (Existing = 4) The existing building has an approved automatic fire sprinkler system installed. Fire resistance rating per table 601: Primary Structural Frame: 1hour Exterior Bearing Walls : 1 hour Exterior Non-bearing walls: 0 hour Interior Bearing Partitions: 1 hour Interior Non-bearing Partitions: 0 hour Floors: 1 hour Roof: 1 hour Fire resistance rating of wall between dwelling units and sleeping units shall be 1 hour per IBC 708.3 *Per footnote ÒdÓ in table 601 of the 2012 IBC, protection of the primary structural frame may be reduced by 1 hour if the building is protected with an automatic sprinkler system. **Per table 602 of the 2012 IBC, the fire resistance of nonbearing exterior walls is 0 hours if the separation distance is > 30Õ A1.0 A1.0 06/09/17