Project: Manor Vail Unit #348 Renovation 595 East Vail Valley Drive, Unit 212A Vail, CO
81657 Parcel #: 2101-081-05-010
Project # 17.003
Date: REVISED May 19, 2017
Owner: Frison Family LLC. PO Box 1169, Manchester, VT 05255 (703) 759-5257
Marily Hand 802 362 2310 mfhand@sover.net
Contractor: Foster Construction Ltd. PO Box 1952 Edwards, CO 81632 (970) 926-3202,
bfoster@fosterltd.com / sbainbridge@fosterltd.com
Drawings: Foster Sketch Plans
Sheet # Description
A1.0 Cover Page
A1.1 As -Built Floor Plan
A1.2 As-Built Reflected Ceiling Plan
A1.3 New Reflected Ceiling Plan Adding 6, 4 inch LED Can Lights
A1.4 New Door Plan
A2.1 Assemblies
A2.2 Can Light Assemblies
E1 Electrical Load Calculations
Type of Construction: VA
Occupancy Classification: R-2
Proposed Area: No Change to Existing
Allowable Height per tale 503: 4 stories (Existing = 4)
The existing building has an approved automatic fire sprinkler system installed.
Fire resistance rating per table 601:
Primary Structural Frame: 1hour
Exterior Bearing Walls : 1 hour
Exterior Non-bearing walls: 0 hour
Interior Bearing Partitions: 1 hour
Interior Non-bearing Partitions: 0 hour
Floors: 1 hour
Roof: 1 hour
Fire resistance rating of wall between dwelling units and sleeping units shall be 1 hour per IBC 708.3
*Per footnote ÒdÓ in table 601 of the 2012 IBC, protection of the primary structural frame may be reduced by 1 hour if
the building is protected with an automatic sprinkler system.
**Per table 602 of the 2012 IBC, the fire resistance of nonbearing exterior walls is 0 hours if the separation distance is