Loading...
HomeMy WebLinkAboutB17-0217_EPDM-1117_Sure-Seal_EPDM_Kleen_Non-Reinforced_Membranes_PDS_05-24-13_1496773500.pdfOverview Sure-Seal Kleen 45-mil (1.14 mm), 60-mil (1.52 mm) and 90-mil (2.29 mm) roofi ng membranes are non-reinforced Ethylene Propylene Diene Terpolymer (EPDM)-based elastomeric homogenous roof coverings. These roofi ng membranes may be used for new single-ply roof construction and re-roofi ng applications. Membranes are available in widths of up to 10' (3 m) and lengths of up to 100' (30 m). These membranes are available as Fire Retardant (FR) membranes, which are specially formulated to inhibit spread of fl ame and meet or exceed code body testing criteria for the fi re- retardant roofi ng membranes. Features and Benefi ts »Carlisle EPDM has 50 years of proven performance »Industry leading resistance to outdoor weathering with 41,580 kJ/m² total radiant exposure without cracking or crazing »FAT Seam Technology and full line of Pressure-Sensitive Flashing accessories greatly enhance workmanship quality by simplifying the contractors’ job »Dark colored EPDM is the smart choice in colder climates: -Reduces heating costs which are generally 5 times greater than air conditioning costs -Reduces carbon footprint by lowering heating costs -Reduces safety hazard from snow and ice accumulation -Reduces hazardous conditions from frost, dew or ice that is diffi cult to see on white membranes -Reduces potential condensation problems that can erode performance »Life Cycle Assessment using EPA’s TRACI model analyzed EPDM, TPO, PVC and Modifi ed-Bitumen -EPDM had the lowest Global Warming Potential -EPDM had the lowest Acid Rain impact -EPDM had the lowest contribution to Smog »Numerous studies and real world experience confi rm that Sure-Seal EPDM’s 465% elongation and weathering resistance result in superior hail damage resistance; UL 2218 Class 4 rating »EPDM is the most dimensionally stable heat resistant membrane and stays fl exible even in extremely cold conditions, down to -40°F (see Flexibility/Torsion DMA data) »Wide array of Design choices that are UL and FM approved with standard or Low-VOC adhesives »45-mil, 60-mil and 90-mil membranes available for 15, 20 and 30 year warranties »Carlisle manufactures all the major components of a typical roofi ng system including membrane, fl ashings, tapes, adhesives, sealants, insulations and insulating cover boards Carlisle’s FAT Seam Technology With Carlisle’s patented Factory-Applied Tape (FAT) Seam technology, most of the labor to create seams between membrane panels is completed in a quality-controlled, state-of-the-art environment. This process results in a reliable seam with greater peel and sheer strengths and with no entrapped air bubbles. Consistent placement of the FAT also maximizes the splice area and results in a high-quality seam. Carlisle FAT is available on all Sure-Seal Kleen membranes up to 10’ (3 m) in width, providing the fastest way to complete a seam in today’s roofi ng market. 30-Year Warranty The 30-year Sure-Seal EPDM roof system features a thicker, more durable membrane that’s complemented by enhanced details and accessories, creating the most comprehensive roofi ng solution available today. Carlisle’s 90-mil EPDM is used for 30-year warranty installations to provide long-term value and performance. In addition to 30 years of guaranteed protection, this system is available with warranties to cover hail, accidental punctures, and wind speeds up to 120 mph. 800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com EXPERIENCE THE CARLISLE DIFFERENCE Kleen Non-Reinforced Membranes Typical Properties and Characteristics Physical Property Test Method SPEC. (PASS)Typical Tolerance on Nominal Thickness, % ASTM D412 ±10 ±10 Weight, lbs/ft² (kg/m²) 45-mil 60-mil 90-mil 0.29 (1.43) 0.39 (1.91) 0.59 (2.86) Tensile Strength, min, psi (MPa) ASTM D412 1305 (9) 1600 (11.0) Elongation, Ultimate, min, % ASTM D412 300 465 Tear Strength, min, lbf/in (kN/m) ASTM D624 (Die C) 150 (26.3) 200 (35.0) Factory Seam Strength, min Modified ASTM D816 Membrane Rupture Membrane Rupture Resistance to Heat Aging* Properties after 28 days @ 240°F (116°C) Tensile Strength, min, psi (MPa) Elongation, Ultimate, min, % Tear Strength, min, lbf/in (kN/m) Linear Dimensional Change, max, % ASTM D573 ASTM D412 ASTM D412 ASTM D624 ASTM D1204 1205 (8.3) 200 125 (21.9) ±1.0 1450 (10.0) 280 215 (37.6) -0.5 Ozone Resistance* Condition after exposure to 100 pphm Ozone in air for 168 hours @ 104°F (40°C) Specimen is at 50% strain ASTM D1149 No Cracks No Cracks Brittleness Temp., max, °F (°C)* ASTM D746 -49 (-45) -49 (-45) Resistance to Water Absorption* After 7 days immersion @ 158°F (70°C) Change in mass, max, % ASTM D471 +8, -2 +2.0 Water Vapor Permeance* Max, perms ASTM E 96 (Proc. B or BW) 0.10 0.03 Flexibility/Torsion DMA ASTM D5279-08 N/A 225 MPa @ -40°F Resistance to Outdoor (Ultraviolet) Weathering* Xenon-Arc, total radiant exposure at 0.70 W/m² irradiance, 80°C black panel temperature ASTM G155 No Cracks No Crazing 7,560 kJ/m² 3,000 hrs No Cracks No Crazing 41,580 kJ/m² 16,500 hrs At 0.35 W/m² irradiance, 80°C black panel temperature 6,000 hrs 33,000 hrs *Not a Quality Control Test due to the time required for the test or the complexity of the test. However, all tests are run on a statistical basis to ensure overall long-term performance of the sheeting. Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not refl ect the specifi cation range for any particular property of this product. Note: Sure-Seal Kleen non-reinforced EPDM membrane meets or exceeds the minimum requirements set forth by ASTM D4637 for Type I non-reinforced EPDM single-ply roofi ng membranes. EXPERIENCE THE CARLISLE DIFFERENCE 800-479-6832 | P.O. Box 7000 | Carlisle, PA 17013 | Fax: 717-245-7053 | www.carlislesyntec.com 05.24.13 © 2013 Carlisle. REPRINT CODE: 605436 - “Sure-Seal EPDM Kleen Non-Reinforced Product Data Sheet” Carlisle, Sure-Seal, FAT and SecurTAPE are trademarks of Carlisle. LEED is a registered trademark of the U.S. Green Building Council. Installation Sure-Seal Kleen 45-mil (1.14 mm), 60-mil (1.52 mm) and 90-mil (2.29 mm) membranes are utilized primarily in Design A: Fully Adhered Roofi ng Systems. For Design A: Fully Adhered Roofi ng System Insulation is mechanically attached or adhered to the roof deck. The substrate and membrane are coated with Carlisle Bonding Adhesive. The membrane is then rolled into place and broomed down. To complete seams between two adjoining membrane panels, apply primer to the splice area in conjunction with Carlisle’s FAT. As an alternative, Carlisle’s hand-applied SecurTAPE™ may be used. For cold weather splicing below 40°F (5°C), these steps must be followed: 1. Heat the primed area of the bottom membrane with a hot-air gun as the top sheet with FAT is applied and pressed into place. 2. Prior to rolling the splice area with a 2"-wide steel hand roller, apply heat to the top side of the membrane with a hot-air gun. The heated surface should be hot to the touch. Be careful not to burn or blister the membrane. Consult Carlisle specifi cations for complete installation information. Precautions »Use proper stacking procedures to ensure suffi cient stability of the materials. »Exercise caution when walking on a wet membrane. Membranes are slippery when wet. »Membranes with FAT should not be exposed to prolonged jobsite storage temperatures in excess of 90°F (32°C), otherwise the shelf life of the FAT may be affected. »When membranes with FAT are used, shade the tape end of the rolls until ready to use in warm, sunny weather. LEED® Information Pre-consumer Recycled Content 5% Post-consumer Recycled Content 0% Manufacturing Location Carlisle, PA Solar Refl ectance Index 9 Kleen Non-Reinforced Membranes