Loading...
HomeMy WebLinkAboutB17-0226 specs.pdfRadiant Plus Small Insert Owner's Manual A, WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safet warnin s exactl could result in serious in·u , death, or ro ert dama e. -Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. -WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Leave the building immediately • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. -Installation and service must be performed by a qualified installer, service agency or the gas supplier. HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from Tested & • Portland Listed By • Oregon USA c us OMNI-Test Laboratories, Inc. Report# 0028GN101S Omni-Test Laboratories, Inc. Portland, Oregon ANSI Z21.88-2014 CSA 2.33-2014 • Direct Vent Fireplace Insert • Masonry or Factory-Built (Metal) Wood-Burning Fireplace the hot viewing glass is provided with this appliance • and shall be installed for the protection of children Residential or Mobile Home and other at-risk individuals. This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. A conversion kit is supplied with the appliance. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. French language manuals at travisindustries.com Manuels de Fran is Ian ue a travisindustries.com Travis Industries, Inc. ©Copyright 2015, T.I. 12521 Harbour Reach Dr., Mukilteo, WA 98275 www.travisproducts.com 100-01430 $10.00 4151204 f 2 Introduction Introduction We welcome you as a new owner of a Radiant Insert. In purchasing this fireplace insert you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. It is one of the finest home heaters the world over. This manual will explain the installation, operation, and maintenance of this heater. Please familiarize yourself with the Owner's Manual before operating your heater and save the manual for future reference. Included are helpful hints and suggestions that will make the operation and maintenance of your new heater an easier and more enjoyable experience. We offer our continual support and guidance to help you achieve the maximum benefit and enjoyment from your heater. Important Information No other Radiant Insert has the same serial number as yours. The serial number is attached to the appliance near the gas control valve. Register your warranty online at: traviswarranty.com This serial number will be needed in case you require service of any type. Or, mail your warranty card to: Travis Industries House of Fire 12521 Harbour Reach Dr. Mukilteo, WA 98275 Model: Radiant Plus Small Serial Number: Purchase Date: Purchased From: Listing Details Save Your Bill of Sale. To receive full warranty coverage, you will need to show evidence of the date you purchased your heater. Do not mail your Bill of Sale to us. We suggest that you attach your Bill of Sale to this page so that you will have all the information you need in one place should the need for service or information occur. This appliance was listed by Omni-Test Laboratories, Inc. The listing label is attached to the appliance near the gas control valve. A copy is shown on page 40. Massachusetts Approval This manual has been submitted to the Massachusetts Board of State Examiners of Plumbers and Gas Fitters. National Fireplace Institute ©Travis Industries ~ We suggest that our gas INSTITUT£ hearth products be installed and serviced by profes- sionals who are certified in • the U.S. by the National Fireplace Institute• (NFI) as ~~~ NFI Gas Specialists. 4151204 100-01430 f 6 Features and Specifications Features Installation Options ~~~~~~~~~~~~~~~~~~~~~~ Works During Power Outages Blower Optional • Residential or Mobile Home • Fireplace Insert Standing Pilot Remote Programmable Thermostat Included Variable-Rate Heat Output • Masonry or Factory Built (Metal) Wood- Burning Fireplace • Natural Gas or Propane Heating Specifications Natural Gas Approximate Heating Capacity (in square feet)* 400-1,250 Maximum BTU Input Per Hour 25,000 * Heating capacity will vary with floor plan, insulation, and outside temperature. Dimensions See "Surround Panels" for sizing Propane 400-1,250 25,000 See "Surround Panels" for sizing 14.875" (378mm) * * See "Fireplace Requirements" for sizing details. Electrical Specifications (for optional blower) Blower Electrical Rating .......................................... 120 Volts, 60 Hz, Max. 0.55 Amps Fuel This heater is shipped in natural gas (NG) configuration but may be converted to use propane (LP) using the included conversion kit. ©Travis Industries 4151204 100-01430