Loading...
HomeMy WebLinkAboutB17-0227 Asbestos Test Results.pdfDemofition Asbestos Survey 5185 Main Gore Drive Vail, CO 81657 Prepared For: Peter-Murray Development C/O: Brian Clyadon 970-390-3489 PeterM urrayG rou p@gmaiI.com Prepared By: Summit Asbestos Testing, LLC Nicole Rolfe PO Box 927 Breckenridge, CO 80424 970-406-8038 nicole@summitasbestostest.com Survey Date: June 7, 2017 Summit Asbestos Testingjob Number: 2792 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO CERTIFICATION STATEMENT As the certified inspector responsible for the development of this inspection report, I certify that it has been written and reviewed in a manner of full compliance with applicable rules and regulations as required by Federal and State regulations. See Appendix B for copies of certifications. Respectfully Submitted, Signature: A/~&, &,.~ Nicole Rolfe Summit Asbestos Testing, LLC PO Box 927 Breckenridge, CO 80424 (970) 406-8038 Date: r 12-, 2..017 Summit Asbestos Testing, LLC, Asbestos Consulting Firm License# ACF-22742 Expiration Date: February 19, 2018 Nicole Rolfe CDPHE Asbestos Building Inspector, Certification Number: 22581 Expiration Date: February 19, 2018 Page 1 Table of Contents Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO CERTIF•CATION STATEMENT ........................................................................................... 1 1. EXECUTIVE SUMMARY/ SCOPE OF SERVICES ......................................................... 3 2. SITE DESCRIPTION .................................................................................................. 3 3. ASBESTOS INSPECTION METHODOLOGY ................................................................ 3 3.1 Asbestos Sample Density ................................................................................................................... 4 3.2 Homogeneous Areas/Materials ......................................................................................................... 4 3.3 Physical Assessment .......................................................................................................................... 4 3.4 Sample Collection .............................................................................................................................. 5 3.5 Analytical Laboratory Information .................................................................................................... 5 4. ASBESTOS SUMMARY TABLES ................................................................................ 7 4.1 Table 1: Homogeneous Areas in Scope of Work ............................................................................... 7 4.2 Table 2: Bulk Sample Locations and Results .................................................................................... 10 4.3 Table 3: Photo Log ........................................................................................................................... 14 5. FINDINGS ............................................................................................................. 14 6. RECOMMENDATIONS .......................................................................................... 14 7. STATE and FEDERAL COMPLIANCE & REGULATORY REQUIREMENTS ................... 15 7.1 Colorado Air Quality Control Commission Requirements ............................................................... 15 7.2 National Emission Standards for Hazardous Pollutants (NESHAPS) ................................................ 16 7.3 Asbestos Hazard Emergency Response Act (AHERA) ...................................................................... 16 7.4 Occupational Safety and Health Administration {OSHA} ................................................................ 16 8. LIMITATIONS AND ASSUMPTIONS ....................................................................... 17 Appendix A: Sample Area Diagram ............................................................................... 18 Appendix B: Certifications ............................................................................................ 21 Appendix C: Laboratory Analytical Report and Chain of Custody .................................. 23 Page 2 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO 1. EXECUTIVE SUMMARY/ SCOPE OF SERVICES Summit Asbestos Testing was contracted by Brian Claydon of Peter-Murray Development to perform an AHERA asbestos building survey to located Asbestos Containing Building Materials (ACBM} due to the planned demolition at 5185 Main Gore Drive, Vail, CO 81657. Asbestos Containing Material (ACM) is defined by state and federal regulations as any material that contains greater than 1 % asbestos. The results of this limited asbestos containing materials survey determined that asbestos was not 'detet:ted in any of the samples submitted for laboratory analysis. The survey, conducted on June 7, 2017, consisted of a building walk-through of all areas, delineation and quantification of homogeneous areas, an assessment as to whether the suspect ACBM is friable or non- friable, a physical assessment of the condition of the suspect ACBM, collection of representative bulk samples, and delivery of bulk samples of suspect ACBM to an independent analytical laboratory. The scope of the survey included all accessible suspect building materials and interior and exterior building finishes. 2. SITE DESCRIPTION The property is a 4 story single family home with 4 bedrooms and 4.5 half baths located at 5185 Main Gore Drive, Vail, Colorado. According to the Eagle County Assessor's Office records, the date of original constructfon ~ 1987 and the home is approximatety 4,630 square feet. At the time of the survey, several windows and doors were removed. 3. ASBESTOS INSPECTION METHODOLOGY ACM is defined by state and federal regulations as any material that contains greater than 1 % asbestos as determined by laboratory analysis. State and Federal regulations requires that all suspect ACBM be properly sampled and analyzed prior to conducting any renovation or demolition activities above the established trigger levels (32 square feet, or 50 linear feet, or the equivalent of a 55 gallon drum for residential properties, and 160 square feet, 260 linear feet, or the equivalent of a 55 gallon drum for commercial properties). This survey involved identification and sampling of suspect ACBM within the identified scope of work prior to potential renovations. Suspect ACBM includes nearly all building materials with the exception of metal, glass and wood. However, if the metal, glass or wood material contains a coating, then these materials fall into the suspect ACBM category. The sampling protocol and methodology employed by Summit Asbestos Testing is outlined in this section. Page 3 3.1 Asbestos Sample Density Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO AH ERA regulations specify sampling density protocol based on the quantity and type of material. Sample locations in the facility were selected by Summit Asbestos Testing to be representative of the various homogeneous materials. The Summit Asbestos Testing inspector collected the appropriate number of representative samples at selected locations using a random sampling scheme. Sample density was selected using the following regulatory criteria: (• for surfacing materiais, a minimum of 3 bulk samples collected of homogeneous areas less than 1,000 square feet. At least 5 bulk samples collected for homogeneous areas between 1,000 square feet and 5,000 square feet. Seven or more bulk samples collected for homogeneous areas greater than 5,000 square feet. •!• For thermal system insulation (TSI), not assumed to be ACM: At least 3 bulk samples from each homogeneous area. At least 1 bulk sample from each homogeneous area of patched TSI if the patched section is less than 6 linear feet or less than 6 square feet. As many samples as necessary from each mechanical system where cement or plaster is used on fittings such as tees, elbows, or valves. •!• For suspect miscellaneous material, not assumed to be ACM, bulk samples are collected in a manner sufficient to determine whether the material is ACM or non-ACM. 3.2 Hon1ogeneous Areas/Materials Prior to collecting any samples, Summit Asbestos Testing performed a visual inspection of all areas within the areas identified in the scope of work to determine the presence of suspected ACBM. Homogeneous areas and materials were identified and listed to develop a sampling plan. The square footage of each homogeneous area was measured in order to determine the appropriate number of samples to be collected. Summit Asbestos Testing attempts to capture the square footage measurements as exacting as possible; however for the purpose of this report the measurements are considered an estimate. This information was recorded on the Homogeneous Areas in Scope of Work Form; see Section 4.1 (Table 1 ). Homogeneous areas are defined by AHERA protocol and state regulation as an area of surfacing material, thermal system insulation material, or miscellaneous material that is uniform in color, appearance, texture, date of application, and/or manufacturers' labels. 3.3 Physical Assessment Summit Asbestos Testing conducted a physical assessment of each identified homogeneous material. The assessment included determining the condition, potential for disturbance, and the friability of the material. By regulatory definition, friable means that materia~ when dry, may be crumbled, pulverized, or reduced to Page 4 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO powder by hand pressure, and includes previously nonfriable material that becomes damaged to the extent that when dry it may be crumbled, pulverized, or reduced to powder by hand pressure. The condition of all confirmed ACBMs were evaluated as: •!• Good (no visible damage or showing only very limited damage), •!• Damaged (less than 25% localiied damage or 10% distributed damage), •!• Significantly damaged (25% or greater localized damage or 10% or greater distributed damaged) 3.4 Sample Collection Bulk samples of suspect ACBM were collected in general conformance with AHERA protocols as outlined in CDPHE's-Colorado Regulation 8. The sampling locations are selected so that they are representative of the homogeneous area with regard to the material present and its potential asbestos content. When fewer than 9 samples are collected per homogeneous area, a random sampling scheme is used to determine the sample locaOon, Each sample collected in this inspection was placed in a sealable container at the time of sampling and assigned a unique sample ID. This unique sample ID was recorded on the sampling container with indelible marker. Sample IDs and sample locations were recorded on the Bulk Sample Locations and Results Form (see Section 4.2-Table 2) and on the Sample Area Diagram (see Appendix A). Each sample location was photographed, however only photographs of confirmed asbestos are included. These photographs are available upon request. See the Photo Log (Section 4.3, Table 3), if applicable. Once sampling was complete, all unique sample IDs were recorded on a chain of custody form, and then submitted to an accredited laboratory. The sampling tools were cleaned between each sample collection to prevent cross contamination. 3.5 Analytical Laboratory Information Forty-three (43) bulk samples were collected and submitted under chain of custody to EMSL, Analytical of Denver, CO (AIHA Lab ID 189946). The samples were analyzed using Polarized Light Microscopy (PLM), per EPA method 600/R-93/116. EMSL, Analytical participates in the National Voluntary Laboratory Accreditation Program (NVLAP), a quality assurance program for PLM analysis. By regulation, a homogeneous area shall be determined to contain ACM based on a finding that the result of any single sample collected from that homogeneous area shows that asbestos is present in an amount greater than one percent. Additionally, a homogeneous area is considered not to contain ACM only if the results of fill samples required to be collected from the area show asbestos in amounts of one percent or less. If the asbestos content of ai Sat'ilnlp)Je of ffJable asbestos is estimated to be 1 % asbestos m: less, but greater than 0% (trace), by a method other than point counting (such as visual estimation), the determination shall Page 5 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO be repeated using the point counting technique with PLM. If the result obtained by point count is different from a result obtained by visual estimation, the point count result must be used. Any materials that contains greater than one percent (1 %) asbestos by PLM analysis is considered an ACM and must be handled in accordance with OSHA, EPA, and applicable state and local regulations. Laboratory analysis results for this project are summarized in Section 4.2. See Appendix C for laboratory report and chain of custody. Page 6 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO 4. ASBESTOS SUMMARY TABLES 4.1 Table 1: Homogeneous Areas in Scope of Work Material Physical Qty in Scope Samples HA# Functional Space/Locations (approximate Category Description sq ft) Collected 1 SM Orange stucco Lower portions of exterior of house 355 3 exterior/grey thin-set 2 MISC Black roofing tar paper Between roof and wooden shingles 2,000 1 3 MISC White insulation Exterior of house between stucco and wood wall 355 1 Main Floor: 2 car garage walls and ceiling, 1 car garage walls 1st Floor: LR Walls/Kitchen Walls and ceiling, Bedroom walls and ceiling, Hallway walls and ceiling 4 SM White orange peel 2"d Floor: Hallway walls and ceiling, Spare >7,000 7 surfacing material bedroom (west of stairs) walls and ceiling, 3rd Floor: Kitchen west wall, living room walls and ceiling, fireplace room walls and ceiling, western room watts and ceiling 5 MISC Drywall/Joint Behind HA4 >7,000 2 Compound Tan Swirl 6x6 tile-1st floor kitchen west wall, counter tops, 6 MISC 70 1 grey thin set 1st floor office counter tops Cream wallpaper 7 MISC with pink 1st floor LR west, north wall, 2nd floor 376 1 flowers/gold east bathroom walls adhesive 8 MISC Brown/white 1st Floor LR east and south wall 317 1 checked wallpaper Page 7 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO with white adhesive Cream/blue specked 9 MISC wallpaper/gold 1st floor bath off kitchen-walls 105 1 adhesive 1st floor bath off kitchen-shower walls 10 MISC 4x4 tan tile/gold and counter top--1st floor SW Office-250 1 mastic Counter top, 2hd floor hall shower walls- 2nd floor master bath shower walls 11 MISC Tan design tile with tan thin-set 1st floor bath (off kitchen)-floor, 2nd 85 1 floor halll bath floor Tan small octagon 1st floor entrance flooring, hallway floorrng, 1st floor hallway bath floor and 12 MISC floor tile with grey counter top, 2nd floor east bath flooring-335 1 thin-set 2nd floor master bath floor 8x8 white ceramic 1st Floor-SW Office Flooring-hot tub 13 MISC tile/gold 265 1 adhesive/grey thinset room wall tiles White floral 14 MISC wallpaper/gold 1st floor SW office walls 425 1 adhesive White cove 15 MISC base/clear adhesive Garage trim, 1st floor hot water room 65 1 Blue floral 16 MISC wallpaper/gold 2nd Floor east bedroom walls 380 1 adhesive White/blue/tan 17 Mt SC striped 2nd Floor hall bathroom walls 250 1 wallpaper/gold adhesive 2nd floor hall bathroom walls, Behind WP 18 SM White Skim Coat SM in the Following: 1st floor LR Walls, 1st 1,350 5 floor hall bath, 2nd floor utility Room, 2nd floor East Bathroom (off bedroom} Page 8 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO 19 MISC Drywall/Joint Behind HA 20 OW: 1,350 1 Compound J/C: 700 White with blue 20 MISC striped 2nd floor master bedroom walls 535 1 wallpaper/gold adhesive Blue tiny floral 3rd floor kitchen wa11s and hallway walls 21 MISC wallpaper/gold 500 1 adhesive to spa room 6x6 white ceramic Backsplash 3rd floor kitchen walls, spa 22 MISC 250 1 tile/ gold adhesive flooring Cream colored 23 SM orange peel surfacing 3rd floor hot tub room walls 330 3 material Drywall/Joint OW: 330 24 MISC Behind HA 23 1 Compound J/C: 170 12x12brown 25 MISC tile/brown 3rd floor fireplace wall 130 1 grout/grey thin-set 26 MISC Bare Drywall 1st floor Hot Water Room, 2nd floor 500 1 plumbing room (behind utility room) Black ThK:k Tar 27 MISC Impregnated Paper Exterior Wafrs behind wood siding 4,000 1 Grey exterior tile Main level entrance way, stairs up to 1st 28 MISC 12x12 and 6x6, grey 275 1 grout, white thin set floor, 1st floor entrance HA=Homogeneous Area Material Category Abbreviations: SM= Surfacing Material, TSI= Thermal System Insulation, MISC= Miscellaneous OW= Drywall, JC= Joint Compound Page 9 1st floor exterior-1 STUC-SM-01 north wall 1st floor exterior-1 STUC-SM-02 north wall 1st floor exterior--1 STUC-SM-03 north wall 2 TARP-M-04 Exterior roof 3 tNS-M-05 Exterior-north wa4~ 2 car garage, east 4 OP-SM-06 wall 1st level kitchen- 4 OP-SM-07 ceffing 2nd floor east 4 OP-SM-08 bedroom, north wall 2nd floor hallway, 4 OP-SM-09 south wall 3rd Floor, western 4 OP-SM-10 fireplace room- south Wall Below east window (of 1st floor office space I Above western window Between middle and eastern windows, 7' west of east exterior wall South side of roof over 2 car garage Below east window (of 1st floor office space) At the south edge of east wall, 1.8' from floor 1' east of west waJI on ceiling, 10' south of north wall 3.6' from floor, 2' west of east wall 1.4' from floor, 1.6' east of entrance into master bedroom Below the eastern large window, 1' from floor Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail. CO D F F ND D F F NO D F F ND G NF NF ND so f F NO G F F ND G F F ND D F F ND D F F ND D F F ND Page 10 limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO 3rd floor, fireplace Bottom on the south 4 OP-SM-11 room--northern G F F ND Pillar side, 1' above manter 1st level east/west 5. 7' from floor, at 4 OP-SM-12 corner with entrance G F F ND hallway-north wall into 1st floor office 1st level east/west 5. 7' from floor, at 5 DW/JC-M-13 corner with entrance G F F ND hallway-north wall into 1st floor office 3rd level West FP S wall-west of the 5 DW/JC-M-14 large Eastern D F F ND Room Window- 1st level kitchen East edge of counter, 6 TSW-M-15 D NF F ND counter 2'north of south wall 7 CRWP-M-16 1st floor living 4.3' from floor, 8.1' G F F ND room-north wall east of west wall 8 BRWH-M-17 1st floor living 4.1' from floor, 6.3' G F F ND room-east wall south of north wall 1st floor bathroom 4.4' from floor-just 9 CRBL-M-18 (off kitchen), north west of entrance into G F F ND wall bathroom 1st floor bathroom 10 4x4Tan-M-19 (off kitchen), west Center on wall D F F ND shower wall 1st floor bathroom Southeast corner floor 11 BAFL-M-20 (off kitchen), floor tile D F F ND 12 OCT-M-21 2nd floor master bath floor South side D F F ND 13 8x8-M-22 3rd floor spa room-Top southern tile on east wall east wall G F F ND 1st floor office-At corner w west wall, 14 WFWP-M-23 G F F ND north wall 4' from ffoor Page 11 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO 15 CB-M-24 2 car garage, south wall Floor trim, 2.6' west of threshold into garage G NF NF ND 2nd floor east 5.1' from floor, 16 BF-M-25 4.3'east of entrance G F F ND bedroom-south wall into room 17 STRIPE-M-26 2nd floor hall bath, 3.1' from floor, 1.5' D F F ND north wall west of door entrance 18 SK-SM-27 2nd floor master bath-north wall 4.5' from floor, 2.2' west of entrance door G F F ND 18 SK-SM-28 1st floor living 3.9' from floor, 5.2' G F F ND room-North Wall south of north wall 2nd floor master adjacent to west wall, 18 SK-SM-29 bath-south wall 5.5' from floor G F F ND DW/JC-M-30 2nd floor master adjacent to west wall, 19 G F F ND bath-south wall 5.5' from floor 2nd floor master 5' from floor, 8.3' west 20 BLWH-M-31 D F F ND bedroom, north wall of east wall 3rd floor kitchen --North facing side, 2.2' 21 BLFL-M-32 from floor, 8" east of G F F ND northern short wall the west edge of wall 3rd floor kitchen-4' from floor, 7 .7'west :n GxGWH-M-33 D F F ND south wall of east wall 4rd floor hot tub 5.4' from floor, 8" 23 CR-SM-34 room, west wall south of north wall G F F ND 4th floor hot tub Above window, 6.6' 23 CR-SM-35 from floor, 3.6' south G F F ND room; east wall of north wall 4th floor hot tub Adjacent to west wall, 23 CR-SM-36 G F F ND room, south wall 3.6' from floor DW/JC-M-37 4th floor hot tub Adjacent to west wall, 24 G F F ND room, south wall 3.6' from floor Page 12 25 18 18 26 27 28 12x12-M-38 SK-SM-39 SK-SM-40 DW/JC-M-41 TH-M-42 GR-M-43 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO 3rd Floor Fireplace Bottom, most Room, west side northern tile G NF 1st floor, hallway East wall as enter bathroom, 4.3' from bathroom (by floor, 1.2' south of stairwell) north wall G F 2nd Floor Utility 3.4' from floor, 2.1' Room, east Wall south of north wall G 1st floor hot water 3.9' from floor, 2.2' room, east wall north of south wall D F 1st floor exterior, Just as enter outside, 5' from floor, 1' from east wall south edge of wall D NF Exterior stairwell up 3rd stair to 1st level G NF HA= Homogeneous Area Condition Abbreviations: SD= Significantly Damaged, D= Damaged, G= Good Results: ND= None Detected 1 Current Condition: Is the Material Friable or Non-Friable in Current Condition: F= Friable NF=Non-Friable F ND F ND ND F ND NF ND F ND 2 Due To Reno/Demo: If the Material is Non-Friable in Current Condition, Will it Become Friable when Disturbed by Renovation or Demolition: F= Friable NF=Non-Friable If any samples in the same Homogeneous Area (HA#) contain asbestos, then all samples in the same Homogeneous Area (HA#) must be considered asbestos containing. Page 13 4.3 Table 3: Photo Log Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO Only photos of sample locations of confirmed asbestos are shown in the photo log. Forty-three (43) samples were submitted for lab analysis. All samples came back non-detect for asbestos. Photos of sample locations are available upon request. 5. FINDINGS The results of this asbestos building survey conducted at 5185 Main Gore Drive, Vail, Colorado 81657 indicate that: None of the suspect building materials sampled were found to contain more than one percent (1%) asbestos. If any suspect asbestos containing material is discovered during renovation or demolition, not identified in this report and within the scope of renovation, it must be sampled by a Colorado State Certified Asbestos Inspector prior to proceeding with work. 6. RECOMMENDATIONS Based on the laboratory analytical results, any identified asbestos containing materials should be removed by a Colorado State Certified General Abatement Contractor prior to conducting any removal or demolition activities associated with these materials. All work associated with these materials must be performed in · accordance with all Local, State and Federal regulations. Contractors and employees working in this building should be made aware of the possibility that concealed ACBM may be found during renovation or demolition. Any discovered material must not be disturbed without consulting the owner or manager of the building to determine if those materials were previously identified and sampled to determine if it is ACBM. As per AHERA, a suspect material is to be considered as asbestos containing unless it is proven otherwise by appropriate sampling. Please work safely and if you encounter any other suspect asbestos building materials not listed in this report, please contact a state certified asbestos building inspector for additional sampling. Furthermore, if additional areas are added to the scope of work not identified in this report, sampling of all suspect ACBM within the new areas must be performed prior to renovation/demolition activities, per state and federal regulations. At the time of this report, the EPA has not prohibited the manufacture and import of miscellaneous materials, such as vinyl floorings, mastics, roofing materials, etc., which may be asbestos containing. As a result, Summit Asbestos Testing recommends testing of future replacement materials for the presence of asbestos prior to installation. Page 14 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO 7. STATE and FEDERAL COMPLIANCE & REGULATORY REQUIREMENTS This survey was performed in accordance with Federal, State and local regulations for conducting asbestos building surveys to meet Colorado Air Quality Control Commission (AQCC), Occupational Safety and Health Administration (OSHA), Environmental Protection Agency (EPA), and National Emission Standards for Hazardous Air Pollutants (NESHAP) requirements. 7.1 Colorado Air Quality Control Commission Requirements Colorado Regulation 8 definitions and requirements include: LB. D€finitions: "'Demolition' means the wrecking or taking out of any load-supporting structural member of a facility together with any related handling operations or the intentional burning of any facility ... " 111.C.S. Asbestos Spill Response: ''In the event of an asbestos spill involving less than SO linear feet on pipes, 32 square feet on other surfaces, or the volume equivalent of one SS-gallon drum, the building owner should ... " (Refer to pages 8.114 and 8.11 S for exact recommendations). ''In the event of an asbestos spill involving greater than SO linear feet on pipes, 32 square feet on other surfaces, or the vo~ume equivalent of one SS-gallon drum, the owner shall..." (Refer to page 8.11 S for exact requirements). 111.C.6. Renovation and Demolition Projects: "Prior to any renovation or demolition in any single family housing which may disturb SO linear feet of material on pipes, 32 square feet of material on other surfaces, or the volume equivalent of one SS-gallon drum of material identified by the EPA as a suspect asbestos-containing material the facility components(s) to be affected by the renovation or demolition shall have an inspection performed by a building inspector certified under these regulations. The inspection must be performed to the AH ERA standards as given in 40 CFR Part 763 (1992)." Note: Effective March 30, 2003, State Legislature, House Bill 1016 enacts a quantity change, as well as other regulatory requirements that will alter all of the following minimum level requirements. This format of quantities will remain the same with this notation, until CAQCC Regulation 8 is revised. "Prior to any renovation or demolition in any public or commercial building which may disturb 260 linear feet of material on pipes, 160 square feet of material on other surfaces, or the volume equivalent of one SS- gallon drum of material identified by the EPA as a suspect asbestos-containing material, the facility component(s) to be affected by the renovation or demolition shall have an inspection performed by a building inspector certified under these regulations. The inspection must be performed to the AHERA standards as given in 40 CFR Part 763 {1992)." Page 15 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO 7.2 National Emission Standards for Hazardous Pollutants (NESHAPS) NESHAPS definitions and requirements include: Section 61.141 Definitions: "Demolition means the wrecking or taking out of any load-supporting structural member of a facility together with any related handling operations or the intentional burning of any facility." Section 61.145 Standard of demolition and renovation: "Prior to the commencement of the demolition or renovation, thoroughly inspect the affected facility or part of the facility or part of the facility where the demolition or renovation operation will occur for the presence of asbestos, including Category I and Category II no friable ACM ... " "If a facility is being demolished .. .i~ the combined amount of RACM is at least 260 linear feet on pipes or at least 160 square feet on other facility components, or at least 35 cubic feet off facility components where the length or area could not be measured previously ... " "In a facility being renovated, including any individual nonscheduled renovation operation, if the combined amount of RACM to be stripped, removed, dislodged, cut, drilled, or similarly disturbed ... is at least 260 linear feet on pipes or at least 160 square feet on other facility components, or at least 35 cubic feet off facility components where the length or area could not be measured previously ... " 7.3 Asbestos Hazard Emergency Response Act (AHERA) AHERA definitions and requirements include: As referenced in 40 C.F.R. Part 763 (1992), " ... requires a minimum number of samples for surfacing materials, thermal system insulating materials, and requires samples in a manner sufficient to determine whether the material is ACM or not ACM for miscellaneous materrats. 7.4 Occupational Safety and Health Administration (OSHA) OSHA definitions and requirements include: Any material that contains over one-percent (1 %) of any type of Asbestos is considered Asbestos containing material (ACM) and must be handled according to OSHA and EPA regulations if disturbed. Compliance and Implementation of OSHA 1926.1101 (replaces OSHA 1926.58) is required, as published, no later than October 01, 1995 which requires the Building Owner Methods of Compliance, Respiratory Protection, Hygiene Facilities and Practices for Employees. Communication of Hazards, Housekeeping, Medical Surveillance and the Designation and Training of Competent Persons, including: Page 16 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO The Building/Facility Owner (including a lessee) must identify the presence, location and quantity of ACM and/or PACM(presumed asbestos-containing material) at the work site before beginning work. The Building/Facility Owner must notify, (in writing or in person), the presence, location and quantity of ACM or PACM at the work sites to prospective employers whose employees will work in or next to areas with ACM or PACM. Owner's employees who will work in or next to such areas, all employers on multi-employer worksites whose employees will work in or next to such areas, tenants who will occupy such areas, etc. "An employer or owner may demonstrate that PACM (Presumed Asbestos Containing Material) does not contain asbestos by the following: (A) Having an complete inspection conducted pursuant to the requirements of AHERA (40 CFR Part 763, Subpart E) which demonstrates that the material is not ACM; (B) Performing tests of the material containing PACM which demonstrates that no asbestos is present in the material. .. the tests, evaluation and sample collection shall be conducted by an accredited inspector." Note: The aforementioned regulatory phrases are not the regufations i:n their entirety. Consult the regu~atory ag~ncy, which may apply. 8. LIMITATIONS AND ASSUMPTIONS Summit Asbestos Testing and the findings presented in this Asbestos Survey Report make no representations or assumption as to past and/or future conditions/occurrences of the specific areas surveyed and are based solely oo the coodit~oos observed dunng our survey aind that are noted in this report. The survey did incorporate destructive sampling techniques to identify materials in previously inaccessible areas (behind walls, above ceilings, etc.). These activities created small openings for investigation, but are limited in that full observation is not possible due to the presence of floors, ceilings, etc. Reasonable effort was made by Summit Asbestos Testing to locate and sample accessible suspect building materials within the potential renovation areas identified in the scope of work described in.Section 1. However, it is possible that asbestos-containing materials may be concealed within structures and not identified in this report. The selection of sample locations and frequency of sampling was based on Summit Asbestos Testing's observations and the assumption that like materials in the same area are homogeneous in content (as per AHERA definitions). Summit Asbestos Testing is not responsible or liable for any opinions, conclusions or recommendations provided by others regarding the data presented in this Limited Asbestos Survey. Page 17 I \ Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO Appendix A: Sample Area Diagram (Not To Scale) 1 Car Garage 20 Bedroom -, Ground Level South 6 i I -H ~Q l::.'. I 1st Level South Hot Water Room 2 Car Garage Office __ , Outside l Roof Over 2 Car Ga@ge Page 18 L.., ""'"'~· 33 • • • • Kitchen • I • - Utility Room 40 -! _J- lr - ' ...•... , __ I Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO Hall bath 26 2nd Floor South Hall Bedroom 3rd Floor South Fireplace Room Master Bath 27 Master Bedroom 31 -.J 14 ., • • • -1111111111111111111111La - Page 19 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO Hot Tub Room Above 3rd Floor South 35 I r .. _____ ,. - ~-... "I'"--- Page 20 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO Appendix B: Certifications Colorado Department of Public Health and Environment ASBESTOS CERTIFICATION* This certifies that Nicole Rolfe Certification No.: 22581 has met the requirements of 25-7-507, C.R.S. and Air Quality Control Commission Regulation No. 8, Part B, and is hereby certified by the state of Colorado in the following discipline: Building Inspector* Issued: February 02, 2017 Expires: February 19, 2018 • nm cMi/hvttlt is Wlltd 0111}· wifll llu ~"" of. CIUTlllU Dllliido~Hll trtlhttng '""'~' ""'1iji"'1tlnn in IU dbdp#IM lp«if/d 11"°1¥. Page 21 Limited Asbestos Containing Materials Survey 5185 Main Gore Drive, Vail, CO 1775 We:it ~S'~ Awnue Denver, CO 80221 303.410 4941 trainingchc.com Certif1e5 that Nicole Rolfe Wi81 Has Successfully Completed the EPA-Approved Annual Asbestos Refresher Training Course Under Section 206 of the Toxic Substance Control Act (TSCA), nt1e II. BUILDING INSPECTOR Course Date· Oc.tober 21, 2016 Certificate No_: R16-1214-At-CO Frank Hulce -Instructor No. ol Hours: -·· ----~.!'r...J!-v~---Expiration Date: October 21, 2017 Danaya Benedetto· Traimng Program Manager ASBESTOS CONSULTING FIRM Summit Asbestos Testing, LLC Repcraifoe No.: ACf • 21742 has. t1Wt 1he regisua1lon requircmenLS -of 25~ 7 .. 5Q7, C.. .R.S. and tJJc. Air f,Juahty C..:Onlrol c~ llephuiea No." Pate. an<1 ahecdly-1&pnfonnl!Sbes1Ds~ acUvilles ••required under it<:gulatioil N·o 8, httlt, iii tli.ief.statc uf•t::.micaua. J"""81)' 311, 2017 Fchniory 19, 2018 Page 22 • EMSL Analytical, Inc. 3356 West Catalina Drive Phoenix, AZ 85017 Tel/Fax: (602) 276-4344 / (602) 276-4053 http://www.EMSL.com I phoenixlab@emsl.com Attention: Nicole Rolfe Summit Asbestos Testing PO Box 927 Breckenridge, CO 80424 Project: 5185 Main Gore Drive -Vail, CO EMSLOrder: 121703400 Customer ID: SMAT42 Customer PO: Project ID: Phone: (970) 406-8038 Fax: Received Date: 06/12/2017 9:30 AM Analysis Date: 06/12/2017 Collected Date: 06/07/2017 Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-931116 Method using Polarized Light Microscopy Sample Description Appearance STUC-SM-01-Stucco 1 Orange Exterior Peach Stucco Non-Fibrous 1217034()(}-0001 Homogeneous STUC-SM-01-Stucco 2 Orange Exterior Gray Stucco Non-Fibrous 121703400-0001A Homogeneous STUC-SM-02-Stucco 1 Orange Exterior Peach Stucco Non-Fibrous 1217034oa-D002 Homogeneous STUC-SM-02-Stucco 2 Orange Exterior Gray Stucco Non-Fibrous 1217034oa-D002A Homogeneous STUC-SM-03-Stucco 1 Orange Exterior Orange Stucco Non-Fibrous 1217034()(}-0003 Homogeneous STUC-SM-03-Stucco 2 Orange Exterior Gray Stucco Non-Fibrous 121703400-0003A Homogeneous TARP-M-04 Black Tar Roofing Black Paper Fibrous 121703400-0004 Homogeneous INS-M-05 White Insulation Yellow Fibrous 1217034()(}-0005 Homogeneous OP-SM-06 White Orange f'eet WMe Surfacing Mtl Non-Fibrous 121703400-0006 Homogeneous Paint excluded. OP-SM-07 White Orange Peel White Surfacing Mtl Non-Fibrous 1217034()(}-0007 Homogeneous Paint excluded. OP-SM-08 White Orange Peel White Surfacing Mtl Non-Fibrous 1217034()(}-0008 Homogeneous Paint excluded. OP-SM-09 White Orange Peel White Surfacing MtJ Non-Fibrous 1217034()(}-0009 Homogeneous Paint excluded. OP-SM-10 White Orange Peel White Surfacing Mtl Non-Fibrous 121703400-0010 Homogeneous Paint excluded. OP-SM-11 White Orange Peel White Surfacing Mtl Non-Fibrous 1217034()(}-0011 Homogeneous Paint excluded. { Initial report from: 06/12/2017 15:22:07 ASB_PLM_0008_0001 -1.78 Printed: 6/12/2017 12:22 PM Non-Asbestos % Fibrous % Non-Fibrous 2% Glass 98% Non-fibrous (Other) 100% Non-fibrous (Other) 2% Glass 98% Non-fibrous (Other) 100% Non-fibrous (Other) 2% Glass 98% Non-fibrous (Other) 100% Non-fibrous (Other) 80% Cellulose 20% Non-fibrous (Other) 5% Glass 95% Non-fibrous (Other) 20% Ca Carbonate 80% Non-fibrous (Other) 20% Ca Carbonate 80% Non-fibrous (Other) 20% Ca Carbonate 80% Non-fibrous (Other) 20% Ca Carbonate 80% Non-fibrous (Other) 20% Ca Carbonate 80% Non-fibrous (Other) 20% Ca Carbonate 80% Non-fibrous (Other) Asbestos %Type None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected N'one Detected' None Detected None Detected None Detected None Detected None Detected Page 1 of 5 • EMSL Analytical, Inc. 3356 West Catalina Drive Phoenix, AZ 85017 Tel/Fax: (602) 276-4344 / (602) 276-4053 http://www.EMSL.com I phoenixlab@emsl.com EMSL Order: 121703400 Customer ID: SMAT42 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-931116 Method using Polarized Light Microscopy Non-Asbestos A!!!!!!2! Sample Description Appearance % Fibrous % Non-Fibrous %Type OP-SM-12 White Orange Peel White 20% Ca Carbonate None Detected Surfacing Mtl Non-Fibrous 80% Non-fibrous (other) 1217034()(}-()()12 Homogeneous Paint excluded. DW/JC-M-13-Joint Drywall/Joint White 20% Ca Carbonate None Detected Compound Compound Beneath Non-Fibrous 80% Non-fibrous (other) HA4 Homogeneous 12f70340C>-0013 DW/JC-M-13-Drywall Drywall/Joint Brown/White 10% Cellulose 85%Gypsum None Detected Compound Beneath Fibrous 2%Glass 3% Non-fibrous (Other) 121703400-0013A HA4 Heterogeneous DW/JC-M-14-Joint Drywall/Joint White 20% Ca Carbonate None Detected Compound Compound Beneath Non-Fibrous 80% Non-fibrous (other) HA4 Homogeneous 1217034()()-0014 DW/JC-M-14-Drywall Drywall/Joint Brown/White 10% Cellulose 85%Gypsum None Detected Compound Beneath Fibrous 2%Glass 3% Non-fibrous (Other) 121703400-0014A HA4 Heterogeneous TSW-M-15-Tile Tan Swirl 6x6 Tile -White/Beige 100% Non-fibrous (other) None Detected Firey Thinset Non-Fibrous 121703400-0015 Heterogeneous TSW-M-15-Thinset Tan Swirl 6x6 Tile -Gray 100% Non-fibrous (Other) None Detected Firey Thinset Non-Fibrous 121703400-0015A Homogeneous CRWP-M-16-Wanpaper Cream Wallpaper White 40% Cellulose 150% Non-fibrous (Other) None Detected W/Pink Flowers/Gold Fibrous 121703400-0016 Adhesive Heterogeneous CRWP-M-16-Adhesive Cream Wallpaper Beige 100% Non-fibrous (Other} None Detected W/Pink Flowers/Gold Non-Fibrous 121703400-0016A Adhesive Homogeneous BRWH-M-17-Wallpaper White/Brown White 40% Cellulose 60% Non-fibrous (Other) None Detected Checked Fibrous 121703400-0017 Wallpaper/White Heterogeneous Adhesive BRWH-M-17-Adhesive White/Brown White 100% Non-fibrous (Other) None Detected Checked Non-Fibrous 121703400-0017A Wallpaper/White Homogeneous Adhesive CRBL-M-18-Wallpaper Cream/Blue Speckled White 40% Cellulose 60% Non-fibrous (Other) None Detected Wallpaper With Gold Fibrous 121703400-0018 Adhesive Heterogeneous CRBL-M-18-Adhesive Cream/Blue Speckled White 100% Non-fibrous (Other) None Detected Wallpaper With Gold Non-Fibrous 121703400-0018A Adhesive Homogeneous 4X4TAN-M-19-Tile 4x4 Tan Tile -Gold White 100% Non-fibrous (Other) None Detected Mastic Non-Fibrous 121703400-0019 Heterogeneous 4X4TAN-M-19-Mastic 4x4 Tan Tile -Gold Tan 100% Non-fibrous (Other) None Detected Mastic Non-Fibrous 121703400-0019A Homogeneous BAFL-M-20-Ceramic Tan Designed Tile Tan 100% Non-fibrous (Other) None Detected Tile With Tan Thin-Set Non-Fibrous Heterogeneous 121703400-0020 BAFL-M-20-Thinset Tan Designed Tile Beige 100% Non-fibrous (Other) None Detected With Tan Thin-Set Non-Fibrous 121703400-002DA Homogeneous ( Initial report from: 06/12/2017 15:22:07 ASB_PLM_OOOB_0001·1.78 Printed: 6/12/201712:22 PM Page 2 of 5 • EMSL Analytical, Inc. 3356 West Catalina Drive Phoenix, AZ. 85017 Tel/Fax: (602) 276-4344 / (602) 276-4053 http://www.EMSL.com I phoenixlab@emsl.com EMSL Order: 121703400 Customer ID: SMAT42 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 6(}(]/R-931116 Method using Polarized Light Microscopy Sample Description Appearance OCT-M-21-Ceramic Tile Tan Small Octogon Beige Tile -Grey Thin-Set Non-Fibrous 121703400-0021 Heterogeneous OCT-M-21-Thinset Tan Small Octogon Gray Tile -Grey Thin-Set Non-Fibrous 121703400-0021A Homogeneous 8X8-M-22-Tile 8x8 White Ceramic White/Rust Tile, Gold Adhesi11e Non-Fibrous 121703400-0022 Grey Thin-Set Heterogeneous 8X8-M-22-Adhesive 8x8 White Ceramic Tan Tile, Gold Adhesive Non-Fibrous 121703400-0022A Grey Thin-Set Homogeneous 8X8-M-22-Thinset 8x8 White Ceramic Gray Tile, Gold Adhesive Non-Fibrous 121703400-00228 Grey Thin-Set Homogeneous WFWP-M-23-Wallpaper White Floral Various Wallpaper W/Gold Fibrous 121703400-0023 Adhesive Heterogeneous WFWP-M-23-Adhesive White Floral Tan Wallpaper W/Gold Non-Fibrous 121703400-0023A Adhesive Homogeneous CB-M-24-Cove Base White Cove Base White Non-Fibrous 121703400-0024 Homogeneous CB-M-24-Mastic White Cove Base Beige Non-Fibrous 121703400-0024A Homogeneous BF-M-25-Wallpaper Blue Floral Wallpaper Various Fibrous 121703400-0025 Heterogeneous BF-M-25-Adhesive Blue Floral Wallpaper Beige Non-Fibrous 121703400-0025A Homogeneous STRIPE-M'-26-White/Bklell'an 8eige Wallpaper Striped Wallpaper Fibrous W/Gold Adhesive Heterogeneous 121703400-0026 No Adhesive present SK-SM-27 White Skimcoat White Surfacing Mtl Non-Fibrous 121703400-0027 Homogeneous Paint excluded. SK-SM-28 White Skimcoat White Surfacing Mii Non-Fibrous 121703400-0028 Homogeneous Paint excluded. SK-SM-29 White Skimcoat White Surfacing Mtl Non-Fibrous 121703400-0029 Homogeneous Paint excluded. SK-SM-39 White Skimcoat White Surfacing Mtl Non-Fibrous 121703400-0030 Homogeneous Paint excluded. SK-SM-40 White Skimcoat White Surfacing Mtl Non-Fibrous 121703400-0031 Homogeneous Paint excluded. ( Initial report from: 06/12/2017 15:22:07 ASB_PLM_OOOB_0001 -1.78 Printed: 6/12/2017 12:22 PM Non-Asbestos "lo Fibrous "lo Non-Fibrous 100% Non-fibrous (Other) 100% Non-fibrous (Other) 100% Non-fibrous (Other) 100% Non-fibrous (Other) 100% Non-fibrous (Other) 40% Cellulose 60% Non-fibrous (Other) 100% Non-fibrous (Other) 100% Non-fibrous (Other) 100% Non-fibrous (Other) 40% CeUulose 60% Non-fibrous (Other) 100% Non-fibrous (Other) 40% Cellulose 60% Non-fibrous (Other) 20% Ca Carbonate 80% Non-fibrous (Other) 20% Ca Carbonate 80"/o Non-fibrous (Other) 20% Ca Carbonate 80% Non-fibrous (Other) 20% Ca Carbonate 80% Non-fibrous (Other) 20% Ca Carbonate 80% Non-fibrous (Other) Asbestos %Type None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected None Detected Page 3 of 5 • EMSL Analytical, Inc. 3356 West Catalina Drive Phoenix, AZ. 85017 Tel/Fax: (602) 276-4344 / (602) 276-4053 http://www.EMSL.com I phoenixlab@emsl.com EMSL Order: 121703400 Customer ID: SMAT42 Customer PO: Project ID: Test Reporl: Asbestos Analysis of Bulk Materials via EPA 600'R-931116 Method using Polarized Light Microscopy Non-Asbestos Asbestos Sample Description Appearance % Fibrous "lo Non-Fibrous "!.Type DW/JC-M-30-Joint Drywall/Joint White 20% Ca Carbonate None Detected Compound Compound Beneath Non-Fibrous 80% Non-fibrous (Other) HA18 Homogeneous 121703400-0032 DW/JC-M-30-Orywa!! 'DrywaWJoint Brown 10% Cellu1ose 85"!.Gypsum None Detected Compound Beneath Fibrous 2%Glass 3% Non-fibrous (Other) 121703400-0032A HA18 Hetero~eneous BLWH-M-31-Wallpaper White W/Blue Stripes White/Blue 40% Cellulose 60% Non-fibrous (Qt'ner) None Detected Wallpaper Gold Fibrous 121703400-0033 Adhesive Heterogeneous BLWH-M-31-Adhesive White W/Blue Stripes White 100% Non-fibrous (Other) None Detected Wallpaper Gold Non-Fibrous 121703400-0033A Adhesive Homogeneous BLFL-M-32-Wallpaper Tiny Blue Floral Various 40% Cellulose 60% Non-fibrous (Other) None Detected Wallpaper Gok! Filurous 121703400-0034 Adhesive Heterogeneous BLFL-M-32-Adhesive Tiny Blue Floral Beige 100% Non-fibrous (Other) None Detected Wallpaper Gold Non-Fibrous 12170340<J-0034A Adhesive Homogeneous 6X6WH-M-33-Ceramic 6x6 White Ceramic White 100% Non-fibrous (Other) None Detected Tile Tile W/ Gold Adhesive Non-Fibrous Homogeneous 121703400-0035 6X6WH-M-33-Adhesive 6x6 White Ceramic Tan 100% Non-fibrous (Other) None Detected ne W/ Gold Adhesive Non-Fibrous 1217034-00--0035A Homogeneous CR-SM-34 Cream Colored White 20% Ca Carbonate None Detected Orange Peel Non-Fibrous 80% Non-fibrous (Other) 121703400-0036 Surfacing Mtl Homogeneous Paint excluded. CR-SM-35 Cream Colored White 20% Ca Carbonate None Detected Orange Peel Non-Fibrous 80% Non-fibrous (Other) 121703400-0037 Surfacing Mtl Homogeneous Paint excluded. CR-SM-36 Cream Colored White 20% Ca Carbonate None Detected Orange Peel Non-Fibrous 80% Non-fibrous (Other) 121703400-0038 Surfacing Mtl Homogeneous Paint excluded. DW/JC-M-37-Joint Drywall/Joint White 100% Non-fibrous (Other) None Detected Compound Compound Beneath Non-Fibrous HA23 Homogeneous 121703400-0039 DW/JC-M-37-Drywall Drywall/Joint Brown 10% Cellulose 85% Gypsum None Detected Compound Beneath fibrous 2% G4ass 3% Non-fibrous (Other) 12170340().()l)39A HA23 Heterogeneous 12X12-M-38-Tile 12x12 Brown Tile -Brown 100% Non-fibrous (Other) None Detected Brown Grout -Grey Non-Fibrous 121703400-0040 Thin-Set Heterogeneous 12X 12-M-38-Grout 12x12 Brown Tile -Brown 100% Non-fibrous (Other) None Detected Brown Grout -Grey Non-Fibrous 121703400-0040A Thin-Set Homogeneous 12X12-M-38-Thinset 12x12 Brown Tile -Gray 100% Non-fibrous (Other) None Detected Brown Grout -Grey Non-Fibrous 121703400-00408 Thin-Set H'omogeneous DW/JC-M-41-Joint Bare Drywall W/Joint White 20% Ca Carbonate None Detected Compound Compound At Seams Non-Fibrous 80% Non-fibrous (Other) Homogeneous 121703400-0041 (Initial report from: 06/12/201715:22:07 ASB_PLM_0008_0001 -1.78 Printed: 6/12/2017 12:22 PM Page 4 of 5 • EMSL Analytical, Inc. 3356 West Catalina Drive Phoenix, AZ 85017 Tel/Fax: (602) 276-4344 I (602) 276-4053 http://www.EMSL.com I phoenixlab@emsl.com EMSL Order: 121703400 Customer ID: SMAT42 Customer PO: Project ID: Test Report: Asbestos Analysis. ot Bulk Materials via EPA 600IR•93/116 Method· usirrg Polarized Light Microscopy Sample DW/JC-M-41-Drywall 121703400-0041 A TH-M-42-Tar 121703400-0042 TH-M-42-Paper 121703400-0042A GR-M-43-Tile 121703400-0043 GR-M-43-Grout 121703400-004311 GR-M-43-Thinset 121703400-00438 Analyst(s) lsai Portillo (30) Peter Donato ( 41) Description Bare Drywall W/Joint Compound At Seams Thick Black Tar Impregnated Paper Thick Black Tar Impregnated ?aper Grey Exterior 12x12 Tile & 6x6 Tile Grey Grout, White Thin-Set Grey Exterior 12x 12 Tile & 6x6 Tile Grey G~oot, Whiae lkli11.-5et Grey Exterior 12x12 ne & 6x6 T~e Grey Grout, White Thin-Set Non-Asbestos Appearance % Fibrous Brown/White 10% Cellulose Fibrous Heterogeneous Black 20% Synthetic Fibrous Homogeneous Black 80% Cellulose Fibrous Homogeneous Gray Non-Fibrous Homogeneous Gray Non-Fibrous HomogeJJeous Gray Non-Fibrous Homogeneous % Non-Fibrous 85% Gypsum 5% Non-fibrous (Other) 80% Non-fibrous (Other) 20% Non-fibrous (Other) 100% Non-fibrous (Other) 100% Non-fibrous (Other) 100% Non-fibrous (Other) Michelle Wilson, Laboratory Manager or Other Approved Signatory Asbestos "•Type None Detected None Detected None Detected None Detected None Detected None Detected EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with muttiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1 % Samples analyzed by EMSLAnalytical, Inc. Phoenix, AZ NVLAP Lab Code 200811-0, AZ.0937 ( Initial report from: 06/12/2017 15:22:07 ASB_PLM_OOOB_0001 -1. 78 Printed: 611212017 12:22 PM Page 5 of5 OrderID: 121703400 • EM•L ANALYTICAL, INC_. l..AaOllAT'Olft'•NMIOUCTa•~ Asbestos Chain of Custody EMSL Or er Number (Lab Use Only): -I -lj/) - '--------~-~~--------~ EMSL-Bill to: EMSL ANAL n:CAL INC 1010 YUMA STREET DENVER CO 80204 PHONE \3031 740-5700 FAX (303) 741-1400 Different C~mpa~y: ~ummit Asbestos Testing, LLC If 8111 to is Different note instructions in Comments·· ~------------Th_ird_P_arty~B_il_lin~g_re_q~u_ire_s_w_n_·tten authorization from _third~ [ State/Province: co Zip/Postal Code: 80424 '. Country: USA Street: PO Box 927 City: Breck~_nridge Report To (Name): Nicole Rolfe Fax#: Telephone#: 970-406-8038 Email Address: Nicole@summitasbestostestcom Project Name/Number: ) I lf 5 fv\M N fio ilK '\>~ r-,.... VA-\ L-1 l O Please Provide Results: 0 Fax 0 Email · Purch~O_r:~~:_ _____ ~~~~_!m~S Taken: CQ____=-~ ---------Turnaround Time TAT 0 tions* -Please Check -- 0 3 Hour u6.Hour___ 24 Hour 0 48 Hour 0 72 Hour-· l:::J96Hour -01Week 0 iWeek-- ·For TEM Atr 3 hr through 6 hr please call ahead to schedule •There is a premtUm charge for 3 Hour TEM AHERA or EPA Level II TAT You will be asked to SJgn an authonzat1on form for this service Anal sis com leted m accordance with EMSL ·s Terms and Cond1t1ons located m the Analytical Pnce Gwde PCM -Air i TEM -Air 0 4-4.5hr TAT (AHERA only) I TEM-Dust 0 NIOSH 7400 0 AHERA 40 CFR. Part 763 · 0 Microvac -ASTM D 5755 0 w/ OSHA 8hr. TWA 0 NIOSH 7402 0 Wipe -ASTM D6480 PLM -Bulk (reporting limit) 0 EPA Level II [ 0 Carpet Sonication (EPA 600/J-93/167) l&_pLM EPA 600/R-93/116 (<1%) 0 ISO 10312 Soil/RockNermiculite 0 PLM EPA NOB (<1°/o) TEM -Bulk . 0 PLM CARB 435 - A (0.25% sensitivity) Point Count I 0 TEM EPA NOB 0 PLM CARB 435 - B (0.1 % sensitivity) 0 400 (<0.25%) 0 1000 (<0.1%) ! 0 NYS NOB 198.4 (non-friable-NY) i 0 TEM CARB 435 - B (0.1% sensitivity) Point Count w/Gravimetric 0 Chatfield SOP : 0 TEM CARB 435 -C (0.01% sensitivity) 0 400 (<0.25%) 0 1000 (<0.1 %) 0 TEM Mass Analysis-EPA 600 sec. 2.5 ' 0 EPA Protocol (Semi-Quantitative) I -0 NYS 198.1 (friable in NY) TEM -Water: EPA 100.2 0 EPA Protocol (Quantitative) D NYS 198.6 NOB (non-friable-NY) Fibers >10µm 0 V'.'aste [1 Drinking Other: O NIOSH 9002 <1 % All Fiber Sizes_ 0 _waste 0 Drinking O O Check For Positive Stop -Clearly Identify Homogenous Group Samplers Name: Nicole Rolfe Sample# Samplers Signature: l/\ C1 U ~ Volume/Area HA# Bulk ~,~~ W_l---+-__ Lf t-----~-------t ·---t-~ OI --13 --------~To-~~;-~fSa~;~-s:-ID~V--/.-y-~--~-~-.r~~ D~_te~~)};l.At -:f. /dl_f-Time: ~'. 3 ") W\- Dat_e: ' 1 0 fCf I JJ Time: I Client Sample# (s): Relinquished (Client): Received (Lab): Comments/Special Instructions: t?fnf)( Cor.t;-ol.~ ()oc..;"'lem -Asbe!i.lCS coc -R2 -~ ·2 20~0 \&UJd·-~y\\ u llr/n 91u Page 1 of -1_ pages ") I 1.J Lt4 • .,t1 Paoe 1 of 4 ,-. -- . . OrderID: 121703400 • IE ...... L ~ALY!l(;AL. ~· ur..aOllATOllY•PlitOOUCH•~ Asbestos Chain of Custody EMSL~er Number (La~ use Only! Jl~D1L/DO __ _ EMSL ANALYTICAL, INC 1010 YUMA STREET DENVER CO 80204 PHONE (303) 740-5700 FAX (3031741-1400 Additional Pages of the Chain of Custody are only necessary if needed for additional sample information Sam le# DV-- ~ 0\7--SAA-lO or-sM-\\ o -sM---(v *Comments/Special Instructions: Cor.t~oi;.ea Documen: -Asbesto~ CC.-C -R2 -• '. 2 20 '0 Page_ 2-._ of _1__ pages Paqe 2 Of 4 Volume/Area (Air) HA# Bulk 4 \1- 13 l5 -• OrderID: 121703400 • EM•L ANALYTICAL. INC. Asbestos Chain of Custody EMSL Order Number (Lab Use Only) ,-, -IJllD3l/tD ---~~ EMSL ANALYTICAL INC 1010 YUMA STREET. DENVER CO 80204 PHONE i 303 I 7 40-5700 FAX 1)03) 741-1400 Additional Pages of the Chain of Custody are only necessary if needed for additional sample information Sam le# AA·n ... -- Lwi+-M-3( Cf2--SM -3 Page _l__ of _1_ pages Paqe 3 Of 4 Volume/Area (Air) HA# Bulk I ep Ji- I~ 20 21 Z-3 I ·1 OrderID: 121703400 • ~~~ ANA,LY_!~CAL, INC. ~TCMIY•""'°°'1CTW•~ Asbestos Chain of Custody EMSL Order Number (Lab Use Only): /Jl1U8Lf DD EMSL ANALYTICAL INC 1010 YUMA STREET DENVER CO 80204 PHONE I 303) 7 40-5700 FAX (303l 741-1400 Additional Pages of the Chain of Custody are only necessary if needed for additional sample information Volume/Area (Air) Date/Time Sample# Sample Description HA# (Bulk) Sampled l)wf rc-M--4f ~~V~ift11:\-< l v-1 fe1NL' UM-Ouv{l ~ct 1~~ I £-b l\i)[ 1-101-:r • ' µ 1~--M -4£., r\tv\ ( 1, 1lJltU tc To..fl-~\Nk~ Y ~ a ' · . .> \ ~R-M-4'~ Gt Q.W ~1 e;ru.Ol'L \ Zx\ t-f "~ t-Ct 1< ~ i ~ 2-f? . 1 ~ '1 rv·i.1.+ , vJNJ-e., T"'-1 vt -s eJ· *Comments/Special Instructions: Page _1_ of __j_ pages l _____ _ Paqe 4 Of 4 ------------------------------------