Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B17-0227_5185 Main Gore Drive-Heating System Detail_1497223320.PDF
Heating System Detail Project #:5185 Main Gore Drive Project Information June 01, 2017 Project #: Name: Location: Gordon Mason Residence 5185 Main Gore Drive Vail, CO Notes: Design Conditions and Summary Note that this project has rooms that may require a supplemental heat supply to meet the design load. Load Calculation Method:Manual J8 Design Location:(User Specified) Vail, Colorado Outdoor Temperature:-20.0 °F Floorplans / Levels: Garage Level 1,064 ft² Entry Level 1,328 ft² Second Level 2,378 ft² Upper Level 2,656 ft² Total Area:7,426 ft² Total Tubing Lengths: Barrier PEX 1/2"8,850 ft Total RH Circuits:45 Total Manifolds:12 Total Zones:12 Fluid Type:30% Propylene Glycol Total Tubing Volume:81.47 USG Glycol Volume (30%):24.44 USG Component Losses:128,002 Btu/hr Infiltration/Ventilation:45,474 Btu/hr Radiant Back Losses:13,237 Btu/hr Total Heating Load:186,713 Btu/hr Radiant Heating:134,657 Btu/hr Radiant Back Losses:13,237 Btu/hr Other:38,819 Btu/hr Total Heating Load:186,713 Btu/hr Zone Heating Summary Zone #Area Heating Types RH Circuits Flowrate Head Loss Supplemental Rooms 101 1,064 RH,FC 5 2.17 3.2 184 3 Car Garage, Garage Level Hall 201 555 RH,FC 3 1.22 3.1 3,809 Entry / Mud Room, Entry Level Powder, Coat Closet 202 773 RH 4 0.93 1.9 0 Sitting/Music, Wine, Yoga Areas 301 499 RH,FC 4 1.17 2.7 5,012 Bedroom / Closet 1 302 124 RH 1 0.10 1.2 0 Bath 1 303 691 RH,FC 2 0.78 4.2 7,454 Laundry Room, Second Level Hall 304 556 RH,FC 3 0.67 2.0 554 Bedroom / Closet 2 , Bath 2 305 509 RH,FC 3 1.02 2.8 3,965 Bath 3 , Office / Bedroom 3 401 596 RH,FC 6 1.41 1.8 7,589 Master Bedroom, Master Closet 2 402 345 RH 2 0.37 1.8 0 Master Bath, Upper Level Powder, Master Closet 1 Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 1 of 18 403 765 RH,FC 6 1.76 2.4 5,591 Dining & Living Areas 404 950 RH,FC 6 1.97 3.3 4,663 Kitchen, Breakfast, Informal Seating Total 7,426 RH,FC 45 13.57 4.2 38,819 *RH Loads include internal panel back loss that may not be included in the project total.*RH Loads include internal panel back loss that may not be included in the project total. Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 2 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Room Heating Summary Garage Level 3 Car Garage Total Area:899 ft² Heated by:RH Room Temperature:70 °F Floor Covering (Rv):0.0 - Bare concrete, no covering Radiant Heating: Heated Area:860 ft² Tubing in Floor:655 ft Circuits in Room:4 Tube Spacing:15 Required Surface Temp:83 °F Required Water Temp:120 °F Est. Peak Output:23,858 Btu/hr Load/Loss Summary: Room Design Load:20,375 Btu/hr Radiant Load:22,133 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:1,758 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:22,133 Btu/hr Elevator Equipment Room Total Area:39 ft² Heated by:NH Room Temperature:60 °F Floor Covering (Rv):0.5 Radiant Heating: Heated Area:34 ft² Tubing in Floor:0 ft Circuits in Room:0 Tube Spacing:12 Required Surface Temp:60 °F Required Water Temp:101 °F Est. Peak Output:0 Btu/hr Load/Loss Summary: Room Design Load:0 Btu/hr Radiant Load:0 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:0 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:0 Btu/hr Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 3 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Garage Level Elevator Shaft Total Area:60 ft² Heated by:NH Room Temperature:60 °F Floor Covering (Rv):0.5 Radiant Heating: Heated Area:52 ft² Tubing in Floor:0 ft Circuits in Room:0 Tube Spacing:12 Required Surface Temp:60 °F Required Water Temp:122 °F Est. Peak Output:0 Btu/hr Load/Loss Summary: Room Design Load:0 Btu/hr Radiant Load:0 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:0 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:0 Btu/hr Garage Level Hall Total Area:165 ft² Heated by:RH,FC Room Temperature:70 °F Floor Covering (Rv):6H - (R=0.7/U=1.471) Hardwood Flooring, 0.75" Radiant Heating: Heated Area:111 ft² Tubing in Floor:165 ft Circuits in Room:1 Tube Spacing:15 Required Surface Temp:83 °F Required Water Temp:130 °F Est. Peak Output:2,398 Btu/hr Supplemental Req'd:184 Btu/hr Load/Loss Summary: Room Design Load:2,398 Btu/hr Radiant Load:2,729 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:184 Btu/hr Radiant Back Loss:331 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:2,912 Btu/hr Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 4 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Entry Level Coat Closet Total Area:144 ft² Heated by:RH,FC Room Temperature:70 °F Floor Covering (Rv):6C - (R=1.2/U=0.813) Carpet and Rubber Pad Radiant Heating: Heated Area:130 ft² Tubing in Floor:163 ft Circuits in Room:1 Tube Spacing:9 Required Surface Temp:83 °F Required Water Temp:139 °F Est. Peak Output:2,496 Btu/hr Supplemental Req'd:623 Btu/hr Load/Loss Summary: Room Design Load:2,496 Btu/hr Radiant Load:3,992 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:623 Btu/hr Radiant Back Loss:1,496 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:4,615 Btu/hr Entry / Mud Room Total Area:361 ft² Heated by:RH,FC Room Temperature:70 °F Floor Covering (Rv):6H - (R=0.7/U=1.471) Hardwood Flooring, 0.75" Radiant Heating: Heated Area:222 ft² Tubing in Floor:354 ft Circuits in Room:2 Tube Spacing:9 Required Surface Temp:85 °F Required Water Temp:135 °F Est. Peak Output:5,349 Btu/hr Supplemental Req'd:3,114 Btu/hr Load/Loss Summary: Room Design Load:5,349 Btu/hr Radiant Load:7,786 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:3,114 Btu/hr Radiant Back Loss:2,436 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:10,900 Btu/hr Entry Level Elevator Shaft Total Area:58 ft² Heated by:NH Room Temperature:60 °F Floor Covering (Rv):0.5 Radiant Heating: Heated Area:52 ft² Tubing in Floor:0 ft Circuits in Room:0 Tube Spacing:12 Required Surface Temp:60 °F Required Water Temp:107 °F Est. Peak Output:0 Btu/hr Load/Loss Summary: Room Design Load:0 Btu/hr Radiant Load:0 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:0 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:0 Btu/hr Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 5 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Entry Level Powder Total Area:50 ft² Heated by:RH,FC Room Temperature:70 °F Floor Covering (Rv):6H - (R=0.7/U=1.471) Hardwood Flooring, 0.75" Radiant Heating: Heated Area:30 ft² Tubing in Floor:178 ft Circuits in Room:1 Tube Spacing:9 Required Surface Temp:83 °F Required Water Temp:132 °F Est. Peak Output:671 Btu/hr Supplemental Req'd:71 Btu/hr Load/Loss Summary: Room Design Load:671 Btu/hr Radiant Load:1,035 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:71 Btu/hr Radiant Back Loss:364 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:1,106 Btu/hr Sitting/Music, Wine, Yoga Areas Total Area:773 ft² Heated by:RH Room Temperature:70 °F Floor Covering (Rv):6H - (R=0.7/U=1.471) Hardwood Flooring, 0.75" Radiant Heating: Heated Area:733 ft² Tubing in Floor:752 ft Circuits in Room:4 Tube Spacing:12 Required Surface Temp:77 °F Required Water Temp:108 °F Est. Peak Output:14,295 Btu/hr Load/Loss Summary: Room Design Load:9,556 Btu/hr Radiant Load:11,068 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:1,512 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:11,068 Btu/hr Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 6 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Second Level Bath 1 Total Area:124 ft² Heated by:RH Room Temperature:70 °F Floor Covering (Rv):6E - (R=0.3/U=3.571) Cork Tile, 0.125" Radiant Heating: Heated Area:94 ft² Tubing in Floor:96 ft Circuits in Room:1 Tube Spacing:12 Required Surface Temp:72 °F Required Water Temp:89 °F Est. Peak Output:1,964 Btu/hr Load/Loss Summary: Room Design Load:388 Btu/hr Radiant Load:614 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:226 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:614 Btu/hr Bath 2 Total Area:119 ft² Heated by:RH Room Temperature:70 °F Floor Covering (Rv):6E - (R=0.3/U=3.571) Cork Tile, 0.125" Radiant Heating: Heated Area:92 ft² Tubing in Floor:170 ft Circuits in Room:1 Tube Spacing:12 Required Surface Temp:72 °F Required Water Temp:89 °F Est. Peak Output:1,733 Btu/hr Load/Loss Summary: Room Design Load:363 Btu/hr Radiant Load:478 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:115 Btu/hr Recovered Back Loss:-115 Btu/hr Total Heat Loss:363 Btu/hr Bath 3 Total Area:169 ft² Heated by:RH,FC Room Temperature:70 °F Floor Covering (Rv):6E - (R=0.3/U=3.571) Cork Tile, 0.125" Radiant Heating: Heated Area:127 ft² Tubing in Floor:194 ft Circuits in Room:1 Tube Spacing:9 Required Surface Temp:85 °F Required Water Temp:121 °F Est. Peak Output:3,910 Btu/hr Supplemental Req'd:2,195 Btu/hr Load/Loss Summary: Room Design Load:3,910 Btu/hr Radiant Load:4,143 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:2,195 Btu/hr Radiant Back Loss:233 Btu/hr Recovered Back Loss:-145 Btu/hr Total Heat Loss:6,193 Btu/hr Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 7 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Bedroom / Closet 1 Total Area:499 ft² Heated by:RH,FC Room Temperature:70 °F Floor Covering (Rv):6C - (R=1.2/U=0.813) Carpet and Rubber Pad Radiant Heating: Heated Area:452 ft² Tubing in Floor:856 ft Circuits in Room:4 Tube Spacing:6 Required Surface Temp:85 °F Required Water Temp:144 °F Est. Peak Output:9,725 Btu/hr Supplemental Req'd:5,012 Btu/hr Load/Loss Summary: Room Design Load:9,725 Btu/hr Radiant Load:10,831 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:5,012 Btu/hr Radiant Back Loss:1,106 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:15,842 Btu/hr Bedroom / Closet 2 Total Area:438 ft² Heated by:RH,FC Room Temperature:70 °F Floor Covering (Rv):6C - (R=1.2/U=0.813) Carpet and Rubber Pad Radiant Heating: Heated Area:396 ft² Tubing in Floor:344 ft Circuits in Room:2 Tube Spacing:12 Required Surface Temp:80 °F Required Water Temp:127 °F Est. Peak Output:6,940 Btu/hr Supplemental Req'd:554 Btu/hr Load/Loss Summary: Room Design Load:6,940 Btu/hr Radiant Load:7,647 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:554 Btu/hr Radiant Back Loss:707 Btu/hr Recovered Back Loss:-521 Btu/hr Total Heat Loss:7,679 Btu/hr Laundry Room Total Area:228 ft² Heated by:RH Room Temperature:70 °F Floor Covering (Rv):6E - (R=0.3/U=3.571) Cork Tile, 0.125" Radiant Heating: Heated Area:115 ft² Tubing in Floor:224 ft Circuits in Room:1 Tube Spacing:10 Required Surface Temp:79 °F Required Water Temp:105 °F Est. Peak Output:3,121 Btu/hr Load/Loss Summary: Room Design Load:1,876 Btu/hr Radiant Load:2,275 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:399 Btu/hr Recovered Back Loss:-21 Btu/hr Total Heat Loss:2,254 Btu/hr Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 8 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Mechanical Room Total Area:211 ft² Heated by:NH Room Temperature:65 °F Floor Covering (Rv):6E - (R=0.3/U=3.571) Cork Tile, 0.125" Radiant Heating: Heated Area:197 ft² Tubing in Floor:0 ft Circuits in Room:0 Tube Spacing:12 Required Surface Temp:65 °F Required Water Temp:101 °F Est. Peak Output:0 Btu/hr Load/Loss Summary: Room Design Load:0 Btu/hr Radiant Load:0 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:0 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:0 Btu/hr Office / Bedroom 3 Total Area:340 ft² Heated by:RH,FC Room Temperature:70 °F Floor Covering (Rv):6C - (R=1.2/U=0.813) Carpet and Rubber Pad Radiant Heating: Heated Area:311 ft² Tubing in Floor:374 ft Circuits in Room:2 Tube Spacing:9 Required Surface Temp:84 °F Required Water Temp:140 °F Est. Peak Output:6,242 Btu/hr Supplemental Req'd:1,769 Btu/hr Load/Loss Summary: Room Design Load:6,242 Btu/hr Radiant Load:6,844 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:1,769 Btu/hr Radiant Back Loss:603 Btu/hr Recovered Back Loss:-603 Btu/hr Total Heat Loss:8,011 Btu/hr Second Level Elevator Shaft Total Area:57 ft² Heated by:NH Room Temperature:60 °F Floor Covering (Rv):0.5 Radiant Heating: Heated Area:52 ft² Tubing in Floor:0 ft Circuits in Room:0 Tube Spacing:12 Required Surface Temp:60 °F Required Water Temp:105 °F Est. Peak Output:0 Btu/hr Load/Loss Summary: Room Design Load:0 Btu/hr Radiant Load:0 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:0 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:0 Btu/hr Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 9 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Second Level Hall Total Area:462 ft² Heated by:RH,FC Room Temperature:70 °F Floor Covering (Rv):6H - (R=0.7/U=1.471) Hardwood Flooring, 0.75" Radiant Heating: Heated Area:243 ft² Tubing in Floor:224 ft Circuits in Room:1 Tube Spacing:10 Required Surface Temp:85 °F Required Water Temp:131 °F Est. Peak Output:5,797 Btu/hr Supplemental Req'd:7,454 Btu/hr Load/Loss Summary: Room Design Load:5,797 Btu/hr Radiant Load:7,058 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:7,454 Btu/hr Radiant Back Loss:1,261 Btu/hr Recovered Back Loss:-370 Btu/hr Total Heat Loss:14,141 Btu/hr Storage Total Area:33 ft² Heated by:NH Room Temperature:65 °F Floor Covering (Rv):0.5 Radiant Heating: Heated Area:29 ft² Tubing in Floor:0 ft Circuits in Room:0 Tube Spacing:12 Required Surface Temp:65 °F Required Water Temp:88 °F Est. Peak Output:0 Btu/hr Load/Loss Summary: Room Design Load:0 Btu/hr Radiant Load:0 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:0 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:0 Btu/hr Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 10 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Upper Level Butler Pantry Total Area:64 ft² Heated by:NH Room Temperature:65 °F Floor Covering (Rv):0.5 Radiant Heating: Heated Area:58 ft² Tubing in Floor:0 ft Circuits in Room:0 Tube Spacing:12 Required Surface Temp:65 °F Required Water Temp:94 °F Est. Peak Output:0 Btu/hr Load/Loss Summary: Room Design Load:0 Btu/hr Radiant Load:0 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:0 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:0 Btu/hr Dining & Living Areas Total Area:765 ft² Heated by:RH,FC Room Temperature:70 °F Floor Covering (Rv):6H - (R=0.7/U=1.471) Hardwood Flooring, 0.75" Radiant Heating: Heated Area:711 ft² Tubing in Floor:1,387 ft Circuits in Room:6 Tube Spacing:6 Required Surface Temp:85 °F Required Water Temp:128 °F Est. Peak Output:19,517 Btu/hr Supplemental Req'd:5,591 Btu/hr Load/Loss Summary: Room Design Load:19,517 Btu/hr Radiant Load:20,547 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:5,591 Btu/hr Radiant Back Loss:1,030 Btu/hr Recovered Back Loss:-932 Btu/hr Total Heat Loss:25,206 Btu/hr Kitchen, Breakfast, Informal Seating Total Area:950 ft² Heated by:RH,FC Room Temperature:70 °F Floor Covering (Rv):0.5 Radiant Heating: Heated Area:785 ft² Tubing in Floor:1,571 ft Circuits in Room:6 Tube Spacing:6 Required Surface Temp:85 °F Required Water Temp:123 °F Est. Peak Output:23,636 Btu/hr Supplemental Req'd:4,663 Btu/hr Load/Loss Summary: Room Design Load:23,636 Btu/hr Radiant Load:24,919 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:4,663 Btu/hr Radiant Back Loss:1,282 Btu/hr Recovered Back Loss:-975 Btu/hr Total Heat Loss:28,608 Btu/hr Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 11 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Master Bath Total Area:206 ft² Heated by:RH Room Temperature:70 °F Floor Covering (Rv):6E - (R=0.3/U=3.571) Cork Tile, 0.125" Radiant Heating: Heated Area:167 ft² Tubing in Floor:158 ft Circuits in Room:1 Tube Spacing:12 Required Surface Temp:80 °F Required Water Temp:112 °F Est. Peak Output:4,105 Btu/hr Load/Loss Summary: Room Design Load:3,020 Btu/hr Radiant Load:3,220 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:200 Btu/hr Recovered Back Loss:-146 Btu/hr Total Heat Loss:3,074 Btu/hr Master Bedroom Total Area:431 ft² Heated by:RH,FC Room Temperature:70 °F Floor Covering (Rv):6C - (R=1.2/U=0.813) Carpet and Rubber Pad Radiant Heating: Heated Area:386 ft² Tubing in Floor:692 ft Circuits in Room:4 Tube Spacing:6 Required Surface Temp:85 °F Required Water Temp:143 °F Est. Peak Output:8,263 Btu/hr Supplemental Req'd:5,942 Btu/hr Load/Loss Summary: Room Design Load:8,263 Btu/hr Radiant Load:9,217 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:5,942 Btu/hr Radiant Back Loss:954 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:15,159 Btu/hr Master Closet 1 Total Area:87 ft² Heated by:RH Room Temperature:70 °F Floor Covering (Rv):6C - (R=1.2/U=0.813) Carpet and Rubber Pad Radiant Heating: Heated Area:81 ft² Tubing in Floor:133 ft Circuits in Room:1 Tube Spacing:12 Required Surface Temp:74 °F Required Water Temp:98 °F Est. Peak Output:1,076 Btu/hr Load/Loss Summary: Room Design Load:527 Btu/hr Radiant Load:623 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:96 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:623 Btu/hr Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 12 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Master Closet 2 Total Area:165 ft² Heated by:RH,FC Room Temperature:70 °F Floor Covering (Rv):6C - (R=1.2/U=0.813) Carpet and Rubber Pad Radiant Heating: Heated Area:152 ft² Tubing in Floor:339 ft Circuits in Room:2 Tube Spacing:6 Required Surface Temp:85 °F Required Water Temp:143 °F Est. Peak Output:3,263 Btu/hr Supplemental Req'd:1,648 Btu/hr Load/Loss Summary: Room Design Load:3,263 Btu/hr Radiant Load:4,159 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:1,648 Btu/hr Radiant Back Loss:897 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:5,807 Btu/hr Upper Level Elevator Shaft Total Area:58 ft² Heated by:NH Room Temperature:60 °F Floor Covering (Rv):0.5 Radiant Heating: Heated Area:52 ft² Tubing in Floor:0 ft Circuits in Room:0 Tube Spacing:12 Required Surface Temp:60 °F Required Water Temp:111 °F Est. Peak Output:0 Btu/hr Load/Loss Summary: Room Design Load:0 Btu/hr Radiant Load:0 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:0 Btu/hr Recovered Back Loss:0 Btu/hr Total Heat Loss:0 Btu/hr Upper Level Powder Total Area:53 ft² Heated by:RH Room Temperature:70 °F Floor Covering (Rv):6E - (R=0.3/U=3.571) Cork Tile, 0.125" Radiant Heating: Heated Area:36 ft² Tubing in Floor:133 ft Circuits in Room:1 Tube Spacing:12 Required Surface Temp:75 °F Required Water Temp:98 °F Est. Peak Output:753 Btu/hr Load/Loss Summary: Room Design Load:346 Btu/hr Radiant Load:407 Btu/hr Baseboard Load:0 Btu/hr Forced Air Load 0 Btu/hr Other Load:0 Btu/hr Radiant Back Loss:61 Btu/hr Recovered Back Loss:-3 Btu/hr Total Heat Loss:403 Btu/hr Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 13 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Radiant Heating Details Manifold Summary Manifold Name Zones Circuits Flowrate Head Loss¹Required Temp. Supplied Temp. Temp Drop Manifold Type Control Type Actuators S/R Length² S/R Pipe Manifold 1 1 5 2.17 3.2 130 126 25 (29)None Selected Manifold 0 -- Manifold 2 1 4 0.93 1.9 108 126 25 (36)None Selected Manifold 0 -- Manifold 3 1 3 1.22 3.1 139 126 25 (22)None Selected Manifold 0 -- Manifold 4 1 4 1.17 2.7 144 126 25 (20)None Selected Manifold 0 -- Manifold 5 1 1 0.10 1.2 89 126 25 (46)None Selected Manifold 0 -- Manifold 6 1 3 0.67 2.0 127 126 25 (59)None Selected Manifold 0 -- Manifold 7 1 6 1.76 2.4 128 126 25 (25)None Selected Manifold 0 -- Manifold 8 1 2 0.37 1.8 112 126 25 (47)None Selected Manifold 0 -- Manifold 9 1 6 1.41 1.8 143 126 25 (20)None Selected Manifold 0 -- Manifold 10 1 6 1.97 3.3 123 126 25 (27)None Selected Manifold 0 -- Manifold 11 1 3 1.02 2.8 140 126 25 (27)None Selected Manifold 0 -- Manifold 12 1 2 0.78 4.2 131 126 25 (38)None Selected Manifold 0 -- Total 12 45 13.57 4.2 144 ----0 -- ¹Total Head loss includes manifold, circuits and supply/return piping if specified., ²S/R Length = one way¹Total Head loss includes manifold, circuits and supply/return piping if specified., ²S/R Length = one way Tubing Circuit Details Manifold 1 ** Head loss for circuit tubing only Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load Actuator A-1 3 Car Garage 160 15 204 Barrier PEX 1/2"0.44 1.9 25 (28)5,247 No A-2 3 Car Garage 165 15 186 Barrier PEX 1/2"0.40 1.7 25 (29)4,797 No A-3 3 Car Garage 165 15 197 Barrier PEX 1/2"0.43 1.9 25 (29)5,080 No A-4 3 Car Garage 165 15 197 Barrier PEX 1/2"0.43 1.9 25 (29)5,075 No A-5 Garage Level Hall 165 15 187 Barrier PEX 1/2"0.47 2.2 25 (23)4,663 No Total -820 972 -2.17 2.2 24,862 0 Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 14 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Manifold 2 ** Head loss for circuit tubing only Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load Actuator B-1 Sitting/Music, Wine, Yoga Areas 180 12 167 Barrier PEX 1/2"0.21 0.7 25 (36)2,519 No B-2 Sitting/Music, Wine, Yoga Areas 190 12 183 Barrier PEX 1/2"0.23 0.8 25 (36)2,764 No B-3 Sitting/Music, Wine, Yoga Areas 190 12 194 Barrier PEX 1/2"0.25 0.9 25 (35)2,926 No B-4 Sitting/Music, Wine, Yoga Areas 192 12 189 Barrier PEX 1/2"0.24 0.9 25 (36)2,859 No Total -752 733 -0.93 0.9 11,068 0 Manifold 3 ** Head loss for circuit tubing only Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load Actuator B-5 Entry / Mud Room 175 9 135 Barrier PEX 1/2"0.44 2.1 25 (22)4,714 No B-6 Coat Closet 163 9 118 Barrier PEX 1/2"0.35 1.3 25 (22)3,633 No B-7 Entry / Mud Room, Entry Level Powder 178 9 129 Barrier PEX 1/2"0.42 1.9 25 (22)4,465 No Total -517 381 -1.22 2.1 12,812 0 Manifold 4 ** Head loss for circuit tubing only Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load Actuator C-1 Bedroom / Closet 1 217 6 115 Barrier PEX 1/2"0.30 1.3 25 (20)2,756 No C-2 Bedroom / Closet 1 210 6 98 Barrier PEX 1/2"0.25 0.9 25 (20)2,383 No C-3 Bedroom / Closet 1 211 8 135 Barrier PEX 1/2"0.35 1.7 25 (19)3,191 No C-4 Bedroom / Closet 1 217 6 103 Barrier PEX 1/2"0.27 1.1 25 (20)2,500 No Total -856 452 -1.17 1.7 10,831 0 Manifold 5 ** Head loss for circuit tubing only Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load Actuator C-5 Bath 1 96 12 94 Barrier PEX 1/2"0.10 0.2 25 (46)614 No Total -96 94 -0.10 0.2 46 614 0 Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 15 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Manifold 6 ** Head loss for circuit tubing only Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load Actuator C-6 Bedroom / Closet 2 173 12 166 Barrier PEX 1/2"0.29 1.0 25 (25)3,373 No C-7 Bedroom / Closet 2 171 12 164 Barrier PEX 1/2"0.29 0.9 25 (25)3,326 No C-8 Bath 2 170 12 159 Barrier PEX 1/2"0.10 0.4 25 (59)1,426 No Total -514 488 -0.67 1.0 8,125 0 Manifold 7 ** Head loss for circuit tubing only Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load Actuator D-1 Dining & Living Areas 232 6 117 Barrier PEX 1/2"0.29 1.3 25 (24)3,396 No D-2 Dining & Living Areas 231 6 117 Barrier PEX 1/2"0.29 1.3 25 (24)3,385 No D-3 Dining & Living Areas 231 6 116 Barrier PEX 1/2"0.29 1.3 25 (24)3,360 No D-5 Dining & Living Areas 232 6 113 Barrier PEX 1/2"0.28 1.3 25 (25)3,292 No D-6 Dining & Living Areas 230 6 122 Barrier PEX 1/2"0.30 1.4 25 (24)3,515 No D-7 Dining & Living Areas 231 6 121 Barrier PEX 1/2"0.30 1.4 25 (24)3,490 No Total -1,387 705 -1.76 1.4 20,439 0 Manifold 8 ** Head loss for circuit tubing only Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load Actuator D-4 Upper Level Powder, Master Closet 1 133 12 129 Barrier PEX 1/2"0.10 0.3 25 (47)1,262 No D-8 Master Bath 158 12 167 Barrier PEX 1/2"0.27 0.8 25 (33)3,220 No Total -291 297 -0.37 0.8 4,482 0 Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 16 of 18 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Manifold 9 ** Head loss for circuit tubing only Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load Actuator D-9 Master Bedroom 173 6 98 Barrier PEX 1/2"0.25 0.8 25 (19)2,348 No D-10 Master Bedroom 175 6 87 Barrier PEX 1/2"0.23 0.7 25 (20)2,105 No D-11 Master Bedroom 173 6 85 Barrier PEX 1/2"0.22 0.6 25 (20)2,057 No D-12 Master Bedroom 172 6 86 Barrier PEX 1/2"0.22 0.7 25 (20)2,083 No D-13 Master Closet 2 173 6 85 Barrier PEX 1/2"0.24 0.7 25 (20)2,336 No D-14 Master Closet 2 166 7 88 Barrier PEX 1/2"0.25 0.7 25 (20)2,324 No Total -1,031 530 -1.41 0.8 13,253 0 Manifold 10 ** Head loss for circuit tubing only Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load Actuator D-15 Kitchen, Breakfast, Informal Seating 250 7 138 Barrier PEX 1/2"0.32 1.7 25 (26)3,835 No D-16 Kitchen, Breakfast, Informal Seating 264 6 133 Barrier PEX 1/2"0.33 1.9 25 (27)3,902 No D-17 Kitchen, Breakfast, Informal Seating 265 6 127 Barrier PEX 1/2"0.31 1.8 25 (27)3,733 No D-18 Kitchen, Breakfast, Informal Seating 262 6 131 Barrier PEX 1/2"0.33 1.8 25 (27)3,872 No D-19 Kitchen, Breakfast, Informal Seating 264 6 126 Barrier PEX 1/2"0.31 1.7 25 (27)3,733 No D-21 Kitchen, Breakfast, Informal Seating 266 7 146 Barrier PEX 1/2"0.36 2.3 25 (26)4,326 No Total -1,571 801 -1.97 2.3 23,399 0 Manifold 11 ** Head loss for circuit tubing only Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load Actuator C-9 Office / Bedroom 3 188 9 136 Barrier PEX 1/2"0.32 1.3 25 (20)3,063 No C-11 Bath 3 194 9 164 Barrier PEX 1/2"0.38 1.8 25 (27)4,516 No C-12 Office / Bedroom 3 186 9 137 Barrier PEX 1/2"0.32 1.3 25 (20)3,081 No Total -567 438 -1.02 1.8 10,661 0 Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 17 of 18 Manifold 12 ** Head loss for circuit tubing only Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load Actuator C-10 Laundry Room 224 10 183 Barrier PEX 1/2"0.29 1.3 25 (38)3,916 No C-14 Second Level Hall 224 10 176 Barrier PEX 1/2"0.49 3.2 25 (23)5,417 No Total -448 359 -0.78 3.2 9,332 0 Disclaimers With the permission of the Air Conditioning Contractors of America (“ACCA”), material is reproduced from Manual J Residential Load Calculation (8th Edition) which is copyrighted by ACCA. The program and data are provided "asis" without warranty of any kind either expressed or implied. The entire risk as the quality and performance of the program and data is with you. In no event will ACCA be liable to you for any damages, including without limitation anylost profits, lost savings, or other incidental or consequential damages arising out of the use or inability to use this program or the data. © 2015 Air Conditioning Contractors of America. All Rights Reserved. www.acca.org ACCA, Manual J and Powered by ACCA Manual J are registered trademarks of the Air Conditioning Contractors of America. All rights reserved. Cold weather humidification, or some lifestyles that produce excessive moisture, may cause condensation to occur if the absolute humidity of the indoor air is too high for the momentary circumstances. Condensation can occur on surfaces or concealed within the structure, and can lead to mold, mildew, frost damage, and moisture damage. The software does not perform calculations for the estimation or detection of possible condensation problems, and it is the designers (i.e. software users) responsibility to do so independently if required. For guidance and additional cautions refer to ACCA Manual J 8th Edition, including Section 1-11 and Section 27. The calculated values shown in this report are based on the data input by the user of the software. Inaccurate or erroneous data input will result in inaccurate or erroneous results. You are strongly advised to review all input data carefully, and to have the calculated results reviewed by an experienced heating professional to ensure reasonableness and suitability for your application. IN NO EVENT WILL AVENIR SOFTWARE INC. (“AVENIR”) OR ITS AFFILIATES BE LIABLE UNDER ANY CONTRACT, NEGLIGENCE, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY CONSEQUENTIAL, INCIDENTAL, INDIRECT ORSPECIAL OR PUNITIVE DAMAGES WHATSOEVER (INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR DATA AND THE LIKE), EVEN IF SUCH PARTYHAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AVENIR’S CUMULATIVE LIABILITY FROM ANY CAUSE RELATED TO OR ARISING FROM THE USE THIS REPORT, AND REGARDLESS OF THE FORM OF THE ACTION, SHALL BE LIMITEDTO NO GREATER THAN THE AMOUNT OF FEES PAID TO AVENIR UNDER THE SOFTWARE LICENSE AGREEMENT. Name:Gordon Mason Residence Project #:5185 Main Gore Drive Heating System Detail June 01, 2017 Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 Length = ft Area = ft² Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft² Rv = hr·ft²·°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated See end of report for important Notes and Disclaimers.Page 18 of 18