HomeMy WebLinkAboutB17-0227_5185 Main Gore Drive-Snow Melt Design_1497223320.PDFSnow Melt System Design Report Project #:5185 Main Gore Drive Project Information June 06, 2017 Project #: Name: Location: Gordon Mason Residence 5185 Main Gore Drive Vail, CO Notes: Design Conditions and Summary Snow Melt System Design Method Specify Loads Manually Fluid Type:50% Propylene Glycol Total Flowrate:34.36 USGPM Max. Head Loss:22.4 ft water Design Temp. Drop:25.0 °F Total Area:3,034 ft² Total Circuit Lengths: Barrier PEX 5/8"4,189 ft Total Circuits:19 Total Manifolds:4 Total Tubing Volume:56.31 USG Glycol Volume (50%):28.15 USG Total Snow Melt Load:380,415 Btu/hr Patio Off Kitchen / Breakfast Total Area:272 ft² Heated Area:272 ft² Construction:Snow Melt - Concrete Slab Depth:5.0 in Tubing:Barrier PEX 5/8" Total Circuits:2 Avg. Circuit Length:182 ft Total Length in panel:351 ft Avg. Tube Spacing:9 in Min Supply Temp:101 °F Design Load:28,458 Btu/hr Downward Loss:5,692 Btu/hr Total Heat Load: (User Specified Load) 34,150 Btu/hr Rear Patio & Deck Total Area:828 ft² Heated Area:828 ft² Construction:Snow Melt - Concrete Slab Depth:5.0 in Tubing:Barrier PEX 5/8" Total Circuits:5 Avg. Circuit Length:228 ft Total Length in panel:1,089 ft Avg. Tube Spacing:9 in Min Supply Temp:101 °F Design Load:86,505 Btu/hr Downward Loss:17,301 Btu/hr Total Heat Load: (User Specified Load) 103,806 Btu/hr Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 See end of report for important Notes and Disclaimers.Page 1 of 4 Snow Melt Total Area:131 ft² Heated Area:131 ft² Construction:Snow Melt - Concrete Slab Depth:5.0 in Tubing:Barrier PEX 5/8" Total Circuits:1 Avg. Circuit Length:186 ft Total Length in panel:173 ft Avg. Tube Spacing:9 in Min Supply Temp:101 °F Design Load:13,714 Btu/hr Downward Loss:2,743 Btu/hr Total Heat Load: (User Specified Load) 16,457 Btu/hr Snow Melt Total Area:1,802 ft² Heated Area:1,802 ft² Construction:Snow Melt - Concrete Slab Depth:5.0 in Tubing:Barrier PEX 5/8" Total Circuits:11 Avg. Circuit Length:227 ft Total Length in panel:2,401 ft Avg. Tube Spacing:9 in Min Supply Temp:101 °F Design Load:188,335 Btu/hr Downward Loss:37,667 Btu/hr Total Heat Load: (User Specified Load) 226,002 Btu/hr Name:Gordon Mason Residence Project #:5185 Main Gore Drive Snow Melt System Design Report June 06, 2017 Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 See end of report for important Notes and Disclaimers.Page 2 of 4 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Snow Melt System Design Report June 06, 2017 Manifold Summary Manifold Name Circuits Flowrate Supplied Temp. Max Temp. Drop Manifold Type S/R Length¹ S/R Pipe Manifold Head Loss Circuit Head Loss S/R Head Loss Total Head Loss² Manifold 1 11 20.41 101 25 None Selected --1.0 21.4 0.0 22.4 Manifold 2 1 1.49 101 25 None Selected --1.0 10.0 0.0 11.0 Manifold 3 5 9.38 101 25 None Selected --1.0 20.2 0.0 21.2 Manifold 4 2 3.08 101 25 None Selected --1.0 10.5 0.0 11.5 Total 19 34.36 -----22.4 (1) S/R Length = one way, (2) Total Head loss includes manifold, circuits and supply/return piping if specified.(1) S/R Length = one way, (2) Total Head loss includes manifold, circuits and supply/return piping if specified. Tubing Circuit Details Manifold 1 ** Head loss for circuit tubing only Circuit Areas Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load B-1 Snow Melt 228 9 162 Barrier PEX 5/8"1.84 17.8 25 (25)20,335 B-2 Snow Melt 224 9 160 Barrier PEX 5/8"1.82 17.1 25 (25)20,116 B-3 Snow Melt 226 9 163 Barrier PEX 5/8"1.85 17.8 25 (25)20,459 B-4 Snow Melt 223 9 162 Barrier PEX 5/8"1.83 17.3 25 (25)20,255 B-5 Snow Melt 224 9 164 Barrier PEX 5/8"1.85 17.8 25 (25)20,512 B-6 Snow Melt 225 9 164 Barrier PEX 5/8"1.86 17.9 25 (25)20,558 B-7 Snow Melt 227 9 164 Barrier PEX 5/8"1.86 18.1 25 (25)20,596 B-8 Snow Melt 226 9 163 Barrier PEX 5/8"1.85 17.9 25 (25)20,474 B-9 Snow Melt 227 9 163 Barrier PEX 5/8"1.85 18.0 25 (25)20,488 B-10 Snow Melt 228 9 163 Barrier PEX 5/8"1.84 17.9 25 (25)20,399 B-11 Snow Melt 243 9 174 Barrier PEX 5/8"1.97 21.4 25 (25)21,810 Total -2,501 1,802 -20.41 21.4 226,002 Manifold 2 ** Head loss for circuit tubing only Circuit Areas Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load A-1 Snow Melt 186 9 131 Barrier PEX 5/8"1.49 10.0 25 (25)16,457 Total -186 131 -1.49 10.0 25 16,457 Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 See end of report for important Notes and Disclaimers.Page 3 of 4 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Snow Melt System Design Report June 06, 2017 Manifold 3 ** Head loss for circuit tubing only Circuit Areas Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load C-1 Rear Patio & Deck 232 9 172 Barrier PEX 5/8"1.95 20.2 25 (25)21,622 C-2 Rear Patio & Deck 226 9 159 Barrier PEX 5/8"1.81 17.1 25 (25)19,997 C-4 Rear Patio & Deck 226 9 168 Barrier PEX 5/8"1.91 18.9 25 (25)21,103 C-5 Rear Patio & Deck 224 9 167 Barrier PEX 5/8"1.89 18.4 25 (25)20,933 C-6 Rear Patio & Deck 229 9 161 Barrier PEX 5/8"1.82 17.6 25 (25)20,151 Total -1,138 828 -9.38 20.2 103,806 Manifold 4 ** Head loss for circuit tubing only Circuit Areas Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss** Temp Drop Load C-7 Patio Off Kitchen / Breakfast 182 9 137 Barrier PEX 5/8"1.55 10.5 25 (25)17,131 C-8 Patio Off Kitchen / Breakfast 182 9 136 Barrier PEX 5/8"1.54 10.4 25 (25)17,019 Total -364 272 -3.08 10.5 34,150 Disclaimers The calculated values shown in this report are based on the data input by the user of the software. Inaccurate or erroneous data input will result in inaccurate or erroneous results. You are strongly advised to review all input data carefully, and to have the calculated results reviewed by an experienced heating professional to ensure reasonableness and suitability for your application. IN NO EVENT WILL AVENIR SOFTWARE INC. (“AVENIR”) OR ITS AFFILIATES BE LIABLE UNDER ANY CONTRACT, NEGLIGENCE, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY CONSEQUENTIAL, INCIDENTAL, INDIRECT ORSPECIAL OR PUNITIVE DAMAGES WHATSOEVER (INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR DATA AND THE LIKE), EVEN IF SUCH PARTYHAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AVENIR’S CUMULATIVE LIABILITY FROM ANY CAUSE RELATED TO OR ARISING FROM THE USE THIS REPORT, AND REGARDLESS OF THE FORM OF THE ACTION, SHALL BE LIMITEDTO NO GREATER THAN THE AMOUNT OF FEES PAID TO AVENIR UNDER THE SOFTWARE LICENSE AGREEMENT. Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 See end of report for important Notes and Disclaimers.Page 4 of 4