HomeMy WebLinkAboutB17-0227_5185 Main Gore Drive-Water Supply Summary_1497223320.PDFWater Supply Summary Project #:5185 Main Gore Drive Project Information June 01, 2017 Project #: Name: Location: Gordon Mason Residence 5185 Main Gore Drive Vail, CO Notes: Supply Summary Note that this project has rooms that may require a supplemental heat supply to meet the design load. Manifold Summary Name Temp Total Flow Head Loss¹Load # Circuits # Zones Water Temperature 126.0 13.57 4.2 149,878 45 12 (1) Headloss includes manifolds, circuits, and supply/return piping if specified, may also contain control valve losses.(1) Headloss includes manifolds, circuits, and supply/return piping if specified, may also contain control valve losses. Manifold Name Circuits Flowrate Required Temp. Supplied Temp. Manifold Type S/R Length¹ S/R Pipe Manifold Head Loss Circuit Head Loss S/R Head Loss Total Head Loss² Manifold 1 5 2.17 130 126 None Selected --1.0 2.2 0.0 3.2 Manifold 2 4 0.93 108 126 None Selected --1.0 0.9 0.0 1.9 Manifold 3 3 1.22 139 126 None Selected --1.0 2.1 0.0 3.1 Manifold 4 4 1.17 144 126 None Selected --1.0 1.7 0.0 2.7 Manifold 5 1 0.10 89 126 None Selected --1.0 0.2 0.0 1.2 Manifold 6 3 0.67 127 126 None Selected --1.0 1.0 0.0 2.0 Manifold 7 6 1.76 128 126 None Selected --1.0 1.4 0.0 2.4 Manifold 8 2 0.37 112 126 None Selected --1.0 0.8 0.0 1.8 Manifold 9 6 1.41 143 126 None Selected --1.0 0.8 0.0 1.8 Manifold 10 6 1.97 123 126 None Selected --1.0 2.3 0.0 3.3 Manifold 11 3 1.02 140 126 None Selected --1.0 1.8 0.0 2.8 Manifold 12 2 0.78 131 126 None Selected --1.0 3.2 0.0 4.2 Total 45 13.57 144 ----4.2 (1) S/R Length = one way, (2) Total Head loss includes manifold, circuits and supply/return piping if specified.(1) S/R Length = one way, (2) Total Head loss includes manifold, circuits and supply/return piping if specified. Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 See end of report for important Notes and Disclaimers.Page 1 of 5 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Water Supply Summary June 01, 2017 Water Temperature ( 126 °F ) Manifold 1 ( 126 °F, None Selected, 5 Circuits ) Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³Actuator A-1 3 Car Garage 160 15 204 Barrier PEX 1/2"0.44 1.9 25 (28)5,247 No A-2 3 Car Garage 165 15 186 Barrier PEX 1/2"0.40 1.7 25 (29)4,797 No A-3 3 Car Garage 165 15 197 Barrier PEX 1/2"0.43 1.9 25 (29)5,080 No A-4 3 Car Garage 165 15 197 Barrier PEX 1/2"0.43 1.9 25 (29)5,075 No A-5 Garage Level Hall 165 15 187 Barrier PEX 1/2"0.47 2.2 25 (23)4,663 No Total -820 972 -2.17 2.2 24,862 0 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Manifold 2 ( 126 °F, None Selected, 4 Circuits ) Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³Actuator B-1 Sitting/Music, Wine, Yoga Areas 180 12 167 Barrier PEX 1/2"0.21 0.7 25 (36)2,519 No B-2 Sitting/Music, Wine, Yoga Areas 190 12 183 Barrier PEX 1/2"0.23 0.8 25 (36)2,764 No B-3 Sitting/Music, Wine, Yoga Areas 190 12 194 Barrier PEX 1/2"0.25 0.9 25 (35)2,926 No B-4 Sitting/Music, Wine, Yoga Areas 192 12 189 Barrier PEX 1/2"0.24 0.9 25 (36)2,859 No Total -752 733 -0.93 0.9 11,068 0 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Manifold 3 ( 126 °F, None Selected, 3 Circuits ) Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³Actuator B-5 Entry / Mud Room 175 9 135 Barrier PEX 1/2"0.44 2.1 25 (22)4,714 No B-6 Coat Closet 163 118 Barrier PEX 1/2"0.35 1.3 25 (22)3,633 No B-7 Entry / Mud Room,Entry Level Powder 178 9 129 Barrier PEX 1/2"0.42 1.9 25 (22)4,465 No Total -517 381 -1.22 2.1 12,812 0 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 See end of report for important Notes and Disclaimers.Page 2 of 5 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Water Supply Summary June 01, 2017 Manifold 4 ( 126 °F, None Selected, 4 Circuits ) Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³Actuator C-1 Bedroom / Closet 1 217 115 Barrier PEX 1/2"0.30 1.3 25 (20)2,756 No C-2 Bedroom / Closet 1 210 98 Barrier PEX 1/2"0.25 0.9 25 (20)2,383 No C-3 Bedroom / Closet 1 211 135 Barrier PEX 1/2"0.35 1.7 25 (19)3,191 No C-4 Bedroom / Closet 1 217 103 Barrier PEX 1/2"0.27 1.1 25 (20)2,500 No Total -856 452 -1.17 1.7 10,831 0 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Manifold 5 ( 126 °F, None Selected, 1 Circuits ) Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³Actuator C-5 Bath 1 96 12 94 Barrier PEX 1/2"0.10 0.2 25 (46)614 No Total -96 94 -0.10 0.2 46 614 0 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Manifold 6 ( 126 °F, None Selected, 3 Circuits ) Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³Actuator C-6 Bedroom / Closet 2 173 12 166 Barrier PEX 1/2"0.29 1.0 25 (25)3,373 No C-7 Bedroom / Closet 2 171 12 164 Barrier PEX 1/2"0.29 0.9 25 (25)3,326 No C-8 Bath 2 170 159 Barrier PEX 1/2"0.10 0.4 25 (59)1,426 No Total -514 488 -0.67 1.0 8,125 0 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Manifold 7 ( 126 °F, None Selected, 6 Circuits ) Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³Actuator D-1 Dining & Living Areas 232 117 Barrier PEX 1/2"0.29 1.3 25 (24)3,396 No D-2 Dining & Living Areas 231 117 Barrier PEX 1/2"0.29 1.3 25 (24)3,385 No D-3 Dining & Living Areas 231 116 Barrier PEX 1/2"0.29 1.3 25 (24)3,360 No D-5 Dining & Living Areas 232 113 Barrier PEX 1/2"0.28 1.3 25 (25)3,292 No D-6 Dining & Living Areas 230 122 Barrier PEX 1/2"0.30 1.4 25 (24)3,515 No D-7 Dining & Living Areas 231 121 Barrier PEX 1/2"0.30 1.4 25 (24)3,490 No Total -1,387 705 -1.76 1.4 20,439 0 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 See end of report for important Notes and Disclaimers.Page 3 of 5 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Water Supply Summary June 01, 2017 Manifold 8 ( 126 °F, None Selected, 2 Circuits ) Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³Actuator D-4 Upper Level Powder,Master Closet 1 133 12 129 Barrier PEX 1/2"0.10 0.3 25 (47)1,262 No D-8 Master Bath 158 12 167 Barrier PEX 1/2"0.27 0.8 25 (33)3,220 No Total -291 297 -0.37 0.8 4,482 0 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Manifold 9 ( 126 °F, None Selected, 6 Circuits ) Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³Actuator D-9 Master Bedroom 173 6 98 Barrier PEX 1/2"0.25 0.8 25 (19)2,348 No D-10 Master Bedroom 175 6 87 Barrier PEX 1/2"0.23 0.7 25 (20)2,105 No D-11 Master Bedroom 173 6 85 Barrier PEX 1/2"0.22 0.6 25 (20)2,057 No D-12 Master Bedroom 172 6 86 Barrier PEX 1/2"0.22 0.7 25 (20)2,083 No D-13 Master Closet 2 173 6 85 Barrier PEX 1/2"0.24 0.7 25 (20)2,336 No D-14 Master Closet 2 166 88 Barrier PEX 1/2"0.25 0.7 25 (20)2,324 No Total -1,031 530 -1.41 0.8 13,253 0 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Manifold 10 ( 126 °F, None Selected, 6 Circuits ) Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³Actuator D-15 Kitchen, Breakfast, Informal Seating 250 129 Barrier PEX 1/2"0.32 1.7 25 (26)3,835 No D-16 Kitchen, Breakfast, Informal Seating 264 131 Barrier PEX 1/2"0.33 1.9 25 (27)3,902 No D-17 Kitchen, Breakfast, Informal Seating 265 125 Barrier PEX 1/2"0.31 1.8 25 (27)3,733 No D-18 Kitchen, Breakfast, Informal Seating 262 130 Barrier PEX 1/2"0.33 1.8 25 (27)3,872 No D-19 Kitchen, Breakfast, Informal Seating 264 125 Barrier PEX 1/2"0.31 1.7 25 (27)3,733 No D-21 Kitchen, Breakfast, Informal Seating 266 145 Barrier PEX 1/2"0.36 2.3 25 (26)4,326 No Total -1,571 785 -1.97 2.3 23,399 0 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 See end of report for important Notes and Disclaimers.Page 4 of 5 Manifold 11 ( 126 °F, None Selected, 3 Circuits ) Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³Actuator C-9 Office / Bedroom 3 188 136 Barrier PEX 1/2"0.32 1.3 25 (20)3,063 No C-11 Bath 3 194 9 164 Barrier PEX 1/2"0.38 1.8 25 (27)4,516 No C-12 Office / Bedroom 3 186 137 Barrier PEX 1/2"0.32 1.3 25 (20)3,081 No Total -567 438 -1.02 1.8 10,661 0 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Manifold 12 ( 126 °F, None Selected, 2 Circuits ) Circuit Rooms Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³Actuator C-10 Laundry Room 224 10 183 Barrier PEX 1/2"0.29 1.3 25 (38)3,916 No C-14 Second Level Hall 224 176 Barrier PEX 1/2"0.49 3.2 25 (23)5,417 No Total -448 359 -0.78 3.2 9,332 0 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Disclaimers With the permission of the Air Conditioning Contractors of America (“ACCA”), material is reproduced from Manual J Residential Load Calculation (8th Edition) which is copyrighted by ACCA. The program and data are provided "asis" without warranty of any kind either expressed or implied. The entire risk as the quality and performance of the program and data is with you. In no event will ACCA be liable to you for any damages, including without limitation anylost profits, lost savings, or other incidental or consequential damages arising out of the use or inability to use this program or the data. © 2015 Air Conditioning Contractors of America. All Rights Reserved. www.acca.org ACCA, Manual J and Powered by ACCA Manual J are registered trademarks of the Air Conditioning Contractors of America. All rights reserved. Cold weather humidification, or some lifestyles that produce excessive moisture, may cause condensation to occur if the absolute humidity of the indoor air is too high for the momentary circumstances. Condensation can occur on surfaces or concealed within the structure, and can lead to mold, mildew, frost damage, and moisture damage. The software does not perform calculations for the estimation or detection of possible condensation problems, and it is the designers (i.e. software users) responsibility to do so independently if required. For guidance and additional cautions refer to ACCA Manual J 8th Edition, including Section 1-11 and Section 27. The calculated values shown in this report are based on the data input by the user of the software. Inaccurate or erroneous data input will result in inaccurate or erroneous results. You are strongly advised to review all input data carefully, and to have the calculated results reviewed by an experienced heating professional to ensure reasonableness and suitability for your application. IN NO EVENT WILL AVENIR SOFTWARE INC. (“AVENIR”) OR ITS AFFILIATES BE LIABLE UNDER ANY CONTRACT, NEGLIGENCE, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY CONSEQUENTIAL, INCIDENTAL, INDIRECT ORSPECIAL OR PUNITIVE DAMAGES WHATSOEVER (INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR DATA AND THE LIKE), EVEN IF SUCH PARTYHAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AVENIR’S CUMULATIVE LIABILITY FROM ANY CAUSE RELATED TO OR ARISING FROM THE USE THIS REPORT, AND REGARDLESS OF THE FORM OF THE ACTION, SHALL BE LIMITEDTO NO GREATER THAN THE AMOUNT OF FEES PAID TO AVENIR UNDER THE SOFTWARE LICENSE AGREEMENT. Name:Gordon Mason Residence Project #:5185 Main Gore Drive Water Supply Summary June 01, 2017 Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 See end of report for important Notes and Disclaimers.Page 5 of 5