HomeMy WebLinkAboutB17-0227_5285 Main Gore Drive-Water Supply Summary_1497223320.PDFWater Supply Summary Project #:5185 Main Gore Drive Project Information June 06, 2017 Project #: Name: Location: Gordon Mason Residence 5185 Main Gore Drive Vail, CO Notes: Supply Summary Manifold Summary Name Temp Total Flow Head Loss¹Load # Circuits Water Temperature 101.0 34.36 22.4 380,415 19 (1) Headloss includes manifolds, circuits, and supply/return piping if specified, may also contain control valve losses.(1) Headloss includes manifolds, circuits, and supply/return piping if specified, may also contain control valve losses. Manifold Name Circuits Flowrate Required Temp. Supplied Temp. Manifold Type S/R Length¹ S/R Pipe Manifold Head Loss Circuit Head Loss S/R Head Loss Total Head Loss² Manifold 1 11 20.41 100 101 None Selected --1.0 21.4 0.0 22.4 Manifold 2 1 1.49 100 101 None Selected --1.0 10.0 0.0 11.0 Manifold 3 5 9.38 100 101 None Selected --1.0 20.2 0.0 21.2 Manifold 4 2 3.08 101 101 None Selected --1.0 10.5 0.0 11.5 Total 19 34.36 101 ----22.4 (1) S/R Length = one way, (2) Total Head loss includes manifold, circuits and supply/return piping if specified.(1) S/R Length = one way, (2) Total Head loss includes manifold, circuits and supply/return piping if specified. Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 See end of report for important Notes and Disclaimers.Page 1 of 3 Name:Gordon Mason Residence Project #:5185 Main Gore Drive Water Supply Summary June 06, 2017 Water Temperature ( 101 °F ) Manifold 1 ( 101 °F, None Selected, 11 Circuits ) Circuit Areas Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³ B-1 Snow Melt 228 9 162 Barrier PEX 5/8"1.84 17.8 25 (25)20,335 B-2 Snow Melt 224 9 160 Barrier PEX 5/8"1.82 17.1 25 (25)20,116 B-3 Snow Melt 226 9 163 Barrier PEX 5/8"1.85 17.8 25 (25)20,459 B-4 Snow Melt 223 9 162 Barrier PEX 5/8"1.83 17.3 25 (25)20,255 B-5 Snow Melt 224 9 164 Barrier PEX 5/8"1.85 17.8 25 (25)20,512 B-6 Snow Melt 225 9 164 Barrier PEX 5/8"1.86 17.9 25 (25)20,558 B-7 Snow Melt 227 9 164 Barrier PEX 5/8"1.86 18.1 25 (25)20,596 B-8 Snow Melt 226 9 163 Barrier PEX 5/8"1.85 17.9 25 (25)20,474 B-9 Snow Melt 227 9 163 Barrier PEX 5/8"1.85 18.0 25 (25)20,488 B-10 Snow Melt 228 9 163 Barrier PEX 5/8"1.84 17.9 25 (25)20,399 B-11 Snow Melt 243 174 Barrier PEX 5/8"1.97 21.4 25 (25)21,810 Total -2,501 1,802 -20.41 21.4 226,002 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Manifold 2 ( 101 °F, None Selected, 1 Circuits ) Circuit Areas Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³ A-1 Snow Melt 186 131 Barrier PEX 5/8"1.49 10.0 25 (25)16,457 Total -186 131 -1.49 10.0 25 16,457 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Manifold 3 ( 101 °F, None Selected, 5 Circuits ) Circuit Areas Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³ C-1 Rear Patio & Deck 232 172 Barrier PEX 5/8"1.95 20.2 25 (25)21,622 C-2 Rear Patio & Deck 226 159 Barrier PEX 5/8"1.81 17.1 25 (25)19,997 C-4 Rear Patio & Deck 226 168 Barrier PEX 5/8"1.91 18.9 25 (25)21,103 C-5 Rear Patio & Deck 224 167 Barrier PEX 5/8"1.89 18.4 25 (25)20,933 C-6 Rear Patio & Deck 229 161 Barrier PEX 5/8"1.82 17.6 25 (25)20,151 Total -1,138 828 -9.38 20.2 103,806 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 See end of report for important Notes and Disclaimers.Page 2 of 3 Manifold 4 ( 101 °F, None Selected, 2 Circuits ) Circuit Areas Served Total Length Tube Spacing Area Covered Tubing Flowrate Head Loss¹ Temp Drop² Load³ C-7 Patio Off Kitchen / Breakfast 182 9 137 Barrier PEX 5/8"1.55 10.5 25 (25)17,131 C-8 Patio Off Kitchen / Breakfast 182 9 136 Barrier PEX 5/8"1.54 10.4 25 (25)17,019 Total -364 272 -3.08 10.5 34,150 (1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss. Disclaimers The calculated values shown in this report are based on the data input by the user of the software. Inaccurate or erroneous data input will result in inaccurate or erroneous results. You are strongly advised to review all input data carefully, and to have the calculated results reviewed by an experienced heating professional to ensure reasonableness and suitability for your application. IN NO EVENT WILL AVENIR SOFTWARE INC. (“AVENIR”) OR ITS AFFILIATES BE LIABLE UNDER ANY CONTRACT, NEGLIGENCE, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY CONSEQUENTIAL, INCIDENTAL, INDIRECT OR SPECIAL OR PUNITIVE DAMAGES WHATSOEVER (INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR DATA AND THE LIKE), EVEN IF SUCH PARTYHAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AVENIR’S CUMULATIVE LIABILITY FROM ANY CAUSE RELATED TO OR ARISING FROM THE USE THIS REPORT, AND REGARDLESS OF THE FORM OF THE ACTION, SHALL BE LIMITEDTO NO GREATER THAN THE AMOUNT OF FEES PAID TO AVENIR UNDER THE SOFTWARE LICENSE AGREEMENT. Name:Gordon Mason Residence Project #:5185 Main Gore Drive Water Supply Summary June 06, 2017 Created Using LoopCAD 2016 (6/7/2017) Version:16.0.0080 See end of report for important Notes and Disclaimers.Page 3 of 3