Project #:5185 Main Gore Drive
Project Information
June 06, 2017
Project #:
Name:
Location:
Gordon Mason Residence
5185 Main Gore Drive
Vail, CO
Notes:
Supply Summary
Manifold Summary
Name Temp Total Flow Head Loss¹Load # Circuits
Water Temperature 101.0 34.36 22.4 380,415 19
(1) Headloss includes manifolds, circuits, and supply/return piping if specified, may also contain control valve losses.(1) Headloss includes manifolds, circuits, and supply/return piping if specified, may also contain control valve losses.
Manifold Name Circuits Flowrate Required
Temp.
Supplied
Temp.
Manifold Type S/R
Length¹
S/R
Pipe
Manifold
Head Loss
Circuit
Head Loss
S/R
Head Loss
Total
Head Loss²
Manifold 1 11 20.41 100 101 None Selected --1.0 21.4 0.0 22.4
Manifold 2 1 1.49 100 101 None Selected --1.0 10.0 0.0 11.0
Manifold 3 5 9.38 100 101 None Selected --1.0 20.2 0.0 21.2
Manifold 4 2 3.08 101 101 None Selected --1.0 10.5 0.0 11.5
Total 19 34.36 101 ----22.4
(1) S/R Length = one way, (2) Total Head loss includes manifold, circuits and supply/return piping if specified.(1) S/R Length = one way, (2) Total Head loss includes manifold, circuits and supply/return piping if specified.
Created Using LoopCAD 2016 (6/7/2017)
Version:16.0.0080
See end of report for important Notes and Disclaimers.Page 1 of 3
Name:Gordon Mason Residence
Project #:5185 Main Gore Drive
Water Supply Summary
June 06, 2017
Water Temperature ( 101 °F )
Manifold 1 ( 101 °F, None Selected, 11 Circuits )
Circuit Areas Served Total
Length
Tube
Spacing
Area
Covered
Tubing Flowrate Head
Loss¹
Temp
Drop²
Load³
B-1 Snow Melt 228 9 162 Barrier PEX 5/8"1.84 17.8 25 (25)20,335
B-2 Snow Melt 224 9 160 Barrier PEX 5/8"1.82 17.1 25 (25)20,116
B-3 Snow Melt 226 9 163 Barrier PEX 5/8"1.85 17.8 25 (25)20,459
B-4 Snow Melt 223 9 162 Barrier PEX 5/8"1.83 17.3 25 (25)20,255
B-5 Snow Melt 224 9 164 Barrier PEX 5/8"1.85 17.8 25 (25)20,512
B-6 Snow Melt 225 9 164 Barrier PEX 5/8"1.86 17.9 25 (25)20,558
B-7 Snow Melt 227 9 164 Barrier PEX 5/8"1.86 18.1 25 (25)20,596
B-8 Snow Melt 226 9 163 Barrier PEX 5/8"1.85 17.9 25 (25)20,474
B-9 Snow Melt 227 9 163 Barrier PEX 5/8"1.85 18.0 25 (25)20,488
B-10 Snow Melt 228 9 163 Barrier PEX 5/8"1.84 17.9 25 (25)20,399
B-11 Snow Melt 243 174 Barrier PEX 5/8"1.97 21.4 25 (25)21,810
Total -2,501 1,802 -20.41 21.4 226,002
(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.
Manifold 2 ( 101 °F, None Selected, 1 Circuits )
Circuit Areas Served Total
Length
Tube
Spacing
Area
Covered
Tubing Flowrate Head
Loss¹
Temp
Drop²
Load³
A-1 Snow Melt 186 131 Barrier PEX 5/8"1.49 10.0 25 (25)16,457
Total -186 131 -1.49 10.0 25 16,457
(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.
Manifold 3 ( 101 °F, None Selected, 5 Circuits )
Circuit Areas Served Total
Length
Tube
Spacing
Area
Covered
Tubing Flowrate Head
Loss¹
Temp
Drop²
Load³
C-1 Rear Patio & Deck 232 172 Barrier PEX 5/8"1.95 20.2 25 (25)21,622
C-2 Rear Patio & Deck 226 159 Barrier PEX 5/8"1.81 17.1 25 (25)19,997
C-4 Rear Patio & Deck 226 168 Barrier PEX 5/8"1.91 18.9 25 (25)21,103
C-5 Rear Patio & Deck 224 167 Barrier PEX 5/8"1.89 18.4 25 (25)20,933
C-6 Rear Patio & Deck 229 161 Barrier PEX 5/8"1.82 17.6 25 (25)20,151
Total -1,138 828 -9.38 20.2 103,806
(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.
Created Using LoopCAD 2016 (6/7/2017)
Version:16.0.0080
See end of report for important Notes and Disclaimers.Page 2 of 3
Manifold 4 ( 101 °F, None Selected, 2 Circuits )
Circuit Areas Served Total
Length
Tube
Spacing
Area
Covered
Tubing Flowrate Head
Loss¹
Temp
Drop²
Load³
C-7 Patio Off Kitchen / Breakfast 182 9 137 Barrier PEX 5/8"1.55 10.5 25 (25)17,131
C-8 Patio Off Kitchen / Breakfast 182 9 136 Barrier PEX 5/8"1.54 10.4 25 (25)17,019
Total -364 272 -3.08 10.5 34,150
(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.(1) Head loss for circuit tubing only. (2) Design Temp Drop (Estimated Actual Drop). (3) Load includes circuit back loss.
Disclaimers
The calculated values shown in this report are based on the data input by the user of the software. Inaccurate or erroneous data input will result in inaccurate or erroneous results. You are strongly advised to review all input data
carefully, and to have the calculated results reviewed by an experienced heating professional to ensure reasonableness and suitability for your application.
IN NO EVENT WILL AVENIR SOFTWARE INC. (“AVENIR”) OR ITS AFFILIATES BE LIABLE UNDER ANY CONTRACT, NEGLIGENCE, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY CONSEQUENTIAL, INCIDENTAL, INDIRECT OR
SPECIAL OR PUNITIVE DAMAGES WHATSOEVER (INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR DATA AND THE LIKE), EVEN IF SUCH PARTYHAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AVENIR’S CUMULATIVE LIABILITY FROM ANY CAUSE RELATED TO OR ARISING FROM THE USE THIS REPORT, AND REGARDLESS OF THE FORM OF THE ACTION, SHALL BE LIMITEDTO NO GREATER THAN THE AMOUNT OF FEES PAID TO AVENIR UNDER THE SOFTWARE LICENSE AGREEMENT.
Name:Gordon Mason Residence
Project #:5185 Main Gore Drive
Water Supply Summary
June 06, 2017
Created Using LoopCAD 2016 (6/7/2017)
Version:16.0.0080
See end of report for important Notes and Disclaimers.Page 3 of 3